You are on page 1of 2

REHEAT CYCLE

SCHEMATIC DIAGRAM:
High
Low
Pressure
Pressure
Turbine
Turbine
1

WT

Reheater
QA
2
Boiler

3 4

Pump
6

5 Condenser

WP
QR
T-S DIAGRAM:

T
Reheating

1 3
P1 = P6

s1 = s2

2
----------
P2 = P3 s3 = s4

5 4
P5 = P4

s
REHEAT CYCLE

FORMULAS:

Heat Added

kJ
QA = (h1 – h6) + (h3 – h2) kg

QA = mS [(h1 – h6) + (h3 – h2)] kW

Turbine Work

kJ
WT = (h1 – h2) + (h3 – h4) kg

WT = mS [(h1 – h2) + (h3 – h4)] kW

Pump Work

kJ
WP = (h6 – h5) kg

WP = mS (h6 – h5) kW
kJ
WP = ṽ5 (P6 – P5) kg

h6 = ṽ5 (P6 – P5) + h5

Heat Rejected in the condenser

kJ
QR = (h4 – h5) kg

QR = mS (h4 – h5) kW

Cooling Water Requirement in Condenser

QR = QWATER

mw = mass flow of cooling water

𝐦𝐬 (𝐡𝟒 − 𝐡𝟓 )
mw =
𝐂𝐩 (𝐭 𝟐 − 𝐭 𝟏 )

Cycle Thermal Efficiency

𝐖𝐓 − 𝐖𝐏
e=
𝐐𝐀