You are on page 1of 6

Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING

Column Design
Column Name C1 Note: Applicable Only to 16pcs rebars
Loads Combos Parallel to X-Direction

Design Paramters

fy = 276 Mpa Checking for Min Flexural Strengths


f'c = 20.7 Mpa Mc = 309.1299349 kN-m
main bar Ø = 16 mm Mb = 168 kN-m
stirrups bar Ø = 10 mm Ratio = 1.840059136 Pass
Concrete Cover = 40 mm
Es = 200000 Mpa Checking for Shear at Joints
Col Height = 3 m
Applied Pu = 162 kN MpbR = 118 kN-m
Applied Mu = 38.39 kN-m MpbL = 50 kN-m

Col-x = 400 mm bw = 250 center


Col-z = 250 mm AstFy = 624.29729212 kN
Effective Depth - x 342 mm AsbFy = 208.09909737 kN
Area = 100000 mm2 Vpb of Col = 56 kN
Vj = 776.3963895 kN
ØVn = 545.967032 Vn2 =
Assumed Steel Ratio = 2% Ratio = 1.422057275 Fail
As = 2000
n= 9.947183943

Use nx= 6
Use nz= 6
Actual As = 1206.371579
Ab = 201.0619298

εsteel = 0.00138
εconc at balance = 0.003

cb = 234.2465753

f = εE use f As T = fAs
d c εsteel = e (mm) M (kN-m)
(Mpa) (Mpa) (mm2) (kN)
F1 0 234.246575 0.00138 276 -276 66.59171
1206.3716 -332.958556 200
F2 0 234.246575 0.003 600 276 0 0 0200
F3 0 234.246575 0.003 600 276 0 0 200 0
F4 0 234.246575 0.003 600 276 0 0 200 0
F5 0 234.246575 0.003 600 276 0 0 200 0
Cc 875.833305 100.445206 87.97326
P = Axial Load Capacity 542.8747 kN
M = Column Moment Capacity 154.565

Applied Pu (kN) Axial Load Capacity (kN)


<
162 542.874749 Column is Safe

Applied Moment (kN-m) Moment Capacity (kN-M)


<
38.39 154.5649674 Column is Safe
Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING

NOTE!!!!! MANUAL INPUT THE NUMBER OF REBARS


no. of Bars (pcs) db (mm) As Fy (Mpa) T=
AstFy = 6 16 1206.371579 414 624.29729212
AsbFy = 2 16 402.12385966 414 208.09909737

Joint Shear Stress Aj (Area of Joint) = Manual input Joint Shear Strength
Vn1 = 7.734532953 x 100000 = 773.4533 kN
Vn2 = 5.45967032 x 100000 = 545.967 kN
Vn3 = 4.549725266 x 100000 = 454.9725 kN

edge 300
center 250

942.4777961
Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING
Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING

Column Design
Column Name C1 Note: Applicable Only to 16pcs rebars
Loads Combos Parallel to other-Direction

Design Paramters

fy = 276 Mpa Checking for Min Flexural Strengths


f'c = 20.7 Mpa Mc = 191.9785219 kN-m
main bar Ø = 16 mm Mb = 183.34 kN-m
stirrups bar Ø = 10 mm Ratio = 1.047117497 Fail
Concrete Cover = 40 mm
Es = 200000 Mpa Checking for Shear at Joints
Col Height = 3 m
Applied Pu = 162 kN MpbR = 129.34 kN-m S
Applied Mu = 75 kN-m MpbL = 54 kN-m

Col-x = 250 mm bw = 250 edge


Col-z = 400 mm AstFy = 416.19819475 kN
Effective Depth - x 192 mm AsbFy = 208.09909737 kN
Area = 100000 mm2 Vpb of Col = 61.11333333 kN
Vj = 563.1839588 kN
ØVn = 580.0899715 Vn1 =
Assumed Steel Ratio = 2% Ratio = 0.9708562231 Pass
As = 2000
n = 9.947184

Use nx= 6
Use nz= 6
Actual As = 1206.372
Ab = 201.0619

εsteel = 0.00138
εconc at balance = 0.003

cb = 131.5068

f = εE use f As T = fAs
d c εsteel = e (mm) M (kN-m)
(Mpa) (Mpa) (mm2) (kN)
F1 0 131.506849 0.00138 276 -276 41.61982
1206.3716 -332.958556 125
F2 0 131.506849 0.003 600 276 0 0 125 0
F3 0 131.506849 0.003 600 276 0 0 125 0
F4 0 131.506849 0.003 600 276 0 0 125 0
F5 0 131.506849 0.003 600 276 0 0 125 0
Cc 786.713425 69.109589 54.36944
P = Axial Load Capacity 453.7549 kN
M = Column Moment Capacity 95.98926

Applied Pu (kN) Axial Load Capacity (kN)


<
162 453.7548689 Column is Safe

Applied Moment (kN-m) Moment Capacity (kN-M)


<
75 95.98926095 Column is Safe
Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING

NOTE!!!!! MANUAL INPUT THE NUMBER OF REBARS


no. of Bars (pcs) db (mm) As Fy (Mpa) T=
AstFy = 4 16 804.24771932 414 416.19819475
AsbFy = 2 16 402.12385966 414 208.09909737

Joint Shear Stress Aj (Area of Joint) = Manual input Joint Shear Strength
Vn1 = 7.73453295 x 75000 = 580.09 kN
Vn2 = 5.45967032 x 75000 = 409.4753 kN
Vn3 = 4.54972527 x 75000 = 341.2294 kN

edge 300
center 400
Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING