Air Cylinders Model Selection
Air Cylinders Model Selection
2
Take the impact at the stroke end into consideration.
MB series
q When an external stopper (shock absorber, etc.) is provided to
absorb the impact, select a stopper with sufficient absorption
capacity.
CM2 series
w Stopping the piston with the cylinder without a stopper:
Verify in Graphs (3) to (10) the absorption capacity of the cushion
that is enclosed in the cylinder.
CJ2 series 1) Rubber bumper ······ Urethane rubber is used for preventing metal-
to-metal contact between the piston and the
cover.
2) Air cushion············ The air in the exhaust side is compressed
slightly before the stroke end, and its
reaction force absorbs the kinetic energy of
the load, thus enabling the piston to stop
quietly.
Step
Front matter 21
2-1 Best Pneumatics
1
Obtain the bore of the cylinder tube. → Refer to Graph (1) and (2).
Graph (1) Graph (2)
Extending Side Cylinder Force (Double acting cylinder) Retracting Side Cylinder Force (Double acting cylinder)
60000 30 6000 60000 6000
50000 0 Bore size (mm)
5000 50000 30 Bore size (mm)
5000
40000 4000 40000 0 4000
25 25
30000 0 3000 30000 0 3000
25000 20 2500 25000 2500
20
20000 180 2000 20000
180
2000
15000 160 1500 15000 160 1500
0 0
14 14
10000
120 1000 10000
120
1000
5 5
10 10
5000 0 30 500 5000 0 500
4000 0 400 4000 30 400
80 0
3000 25 300 3000 80 25 300
2500
0 250 2500 0 250
2000 63 20 200 2000 20 200
0 63
1500 18 150 1500 180 150
50 160 160
0 50 0
1000 14 100 1000 14 100
40 120 40 120
Cylinder force F (N)
5 10 0.5 5 0.5
4 0.4 4 10 0.4
3 0.3 3 0.3
2.5 0.25 2.5 0.25
2 0.2 2 0.2
Operating pressure (MPa)
30 kg
P = 0.5 MPa
Example 1: If the minimum force of 1000 N is necessary to keep the Example 2: To move a load with a 30 kg mass horizontally on a guide as
workpiece pressed as shown in Fig. (1), because this is the shown in Fig. (2), because the load is the same for both the
extending side, use Graph (1) to determine the load factor of extending and retracting sides, use Graph (2), which is the
0.7 and the operating pressure of 0.5 MPa. retracting side with a smaller force. Determine the load factor
Then, seek the point at which the cylinder force of 1000 N of 1, and the operating pressure of 0.4 MPa. Then, seek the
intersects, and this will result in a bore size of 63 mm. point at which it intersects with the load mass of 30 kg, and
this will result in a bore size of 40 mm.
Conversion to gravitational units
Example 3: To pull a load with a 100 kg mass vertically upward as shown
1 MPa ≈ 10.2 kgf/cm2 1 N ≈ 0.102 kgf in Fig. (3), use Graph (2) to determine the load factor of 0.5
1 kgf/cm2 ≈ 0.098 MPa 1 kgf ≈ 9.8 N and the operating pressure of 0.5 MPa.
Then, seek the point at which it intersects with the load mass
Front matter 22 of 100 kg, and this will result in a bore size of 80 mm.
Air Cylinders Model Selection 2-1
Step
2
Take the impact at the stroke end into consideration.
CJ2 CA2
CG1
CM2
CS1
Graph (3) CJ2/CM2 Series Graph (4) CG1 Series Graph (5) CA2/CS1 Series
1000 CG1100 10000
CS1300
200
CG180 CS1250
CM240 500 5000
CA263
30 300
CJ210
5 CA250
20 200
CA240
3
10 100
2
5 50
1
3 30
0.4
2 20
0.3
0.2
1 10
0.5 5
100 200 300 500 1000 100 200 300 500 1000 100 200 300 500 1000
Max. speed (mm/s) Max. speed (mm/s) Max. speed (mm/s)
Front matter 23
2-1 Best Pneumatics
2
Take the impact at the stroke end into consideration.
CJ2
MB CG1
CM2
Graph (6) MB Series Graph (7) CJ2/CM2 Series Graph (8) CG1 Series
1000 CG1100
200
1000
MB100 CG180
CM240 500
100
MB80 CM232 CG163
500 300
50 CM225 CG150
MB63 200
300
CM220
30 CG140
MB50
200
20 100
CG132
MB40 CJ216
100 10 CG125
MB32 50
CJ210 CG120
Load mass (kg)
5 30
50
3 20
30
2 CJ26
20 10
5
10
0.4
0.3 3
5
0.2 2
4
3
0.1 1
2
0.05
0.5
100 200 300 500 1000 2000 100 200 300 500 750 1000 100 200 300 500 1000
Front matter 24
Air Cylinders Model Selection 2-1
1000 1000
CQ2100 CQ2100
CQ280 CQ280
500 500
CQ263 CQ263
300 300
CQ250 CQ250
200 200
CQ240 CQ240
100 CQ232 100 CQ232
CQ225/CQS25 CQ225/CQS25
50 50
CQ220/CQS20 CQ220/CQS20
30 30
Load mass (kg)
CQ216/CQS16 CQ216/CQS16
20 20
CQ212/CQS12 CQ212/CQS12
10 10
5 5
3 3
2 2
1 1
0.5 0.5
0.3 0.3
0.2 0.2
0.1 0.1
50 100 200 300 500 1000 50 100 200 300 500 1000
Front matter 25
2-1 Best Pneumatics
3
The aspects indicated below may need to be taken into consideration, depending on how the
Bushing (Bearing)
q The maximum stroke at which the cylinder can be operated under a lateral load. fR
The region that does not exceed the bold solid line represents the allowable lateral load in relation
to the cylinder of a given stroke length. In the graph, the range of the broken line shows that the
long stroke limit has been exceeded. In this region, as a rule, operate the cylinder by providing a
guide along the direction of movement.
20
Lateral load applied to the rod end fR (N)
CJ2
16
5 CM2
40
CJ 2 4
1
0
3
CM2
32
CJ 2
0.10 2
6
CM2
25
1 CM2
20
0.5
0.4
0.01 0.3
0 15 30 45 60 75 100 125 150 175 200 250 300 350 400 0 100 200 300 400 500 600 700 800 900 1000
Graph (14)
Graph (13) MB Series: ø32, ø40, ø50, ø63, ø80, ø100
CG1 Series: ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 CA2 Series: ø40, ø50, ø63, ø80, ø100
300 300
200
200
100
100
50
Lateral load applied to the rod end fR (N)
40
30
50 MB
20 1
CG11 40 00
00 ·CA
C G 1 8 30 MB 21
10 0 00
8
0·
CG163 20 CA
28
5 MB 0
4 CG1 6
50 3·
3 CA
CG14 10 26
2 0 MB 3
5
CG132 0·
CA
1 MB 2 50
5 4
CG1 0·
25 4 CA
CG12 24
0.5 0 3 MB 0
0.4 3
0.3
2
2
0.2
0.1 1
0 500 1000 1500 0 500 1000 1500
Front matter 26
Air Cylinders Model Selection 2-1
cylinder is operated.
10 10
CD
QS
1000 2
5
CD
5 CQ 5 QS
S 2
Lateral load applied to the rod end fR (N)
CS1 CS180
CS 16 0.5 0.5
50 1 0
140
40 C S1
12
30 5
20
0.1 0.1
10
0 500 1000 1500 2000 2400 0 10 20 30 40 50 0 10 20 30 40 50
Cylinder stroke (mm) Cylinder stroke (mm)
Cylinder stroke (mm)
(Single rod/without switch) (Single rod/without switch)
100 100
CQ2100 CDQ210
0
50 50
40 CQ280 40 CDQ280
30
Lateral load applied to the rod end fR (N)
30
CQ263 20
CDQ263
20
CQ250 CDQ250
10 10
CQ240 CDQ240
CDQ
CQ232 2 25 CDQ232
5.0 CQ2 5.0 CD Q
4.0 25 4.0 CD 220
Q2
3.0 CQ2 3.0 16
CQ 20
2 16 2.0 CD
2.0 Q2
CQ 12
2
1.0 12 1.0
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 50 100 0 50 100
Cylinder stroke (mm) Cylinder stroke (mm)
(Single rod/without switch) (Single rod/without switch)
Front matter 27
2-1 Best Pneumatics
3
The aspects indicated below may need to be taken into consideration, depending on how the
w The relation between the cylinder size and the maximum stroke depending on
the mounting type.
Assuming that the force that is generated by the cylinder itself acts as a buckling force on the piston rod or
on the piston rod and the cylinder tube, the table below indicates in centimeters the maximum stroke that can
be used, which was obtained through calculation. Therefore, it is possible to find the maximum stroke that
can be used with each cylinder size according to the relationship between the level of the operating pressure
and the type of cylinder mounting, regardless of the load factor.
Reference: Even under a light load, if the piston rod has been stopped by an external stopper at the
extending side of the cylinder, the maximum force generated by the cylinder will act upon the P
cylinder itself.
(cm) (cm)
Maximum stroke that can be used
Mounting type Mounting type Maximum stroke that can be used according to buckling strength
Operating
Operating
according to buckling strength
pressure
pressure
CJ2 CM2 CG1
Nominal
Nominal
symbol
symbol
Mounting bracket Mounting bracket
diagram diagram
(MPa) 6 10 16 (MPa) 20 25 32 40 20 25 32 40 50 63 80 100
Foot: L Rod side Rod side Head side
flange: F Foot: L flange: F flange: G 0.3 39 49 56 61 38 49 55 80 100 78 96 112
0.2 20 29 29 LF
W W W W W 0.5 29 37 42 46 29 36 42 60 76 59 73 85
BLF
0.3 20 23 23 0.7 24 31 35 38 24 30 34 50 63 49 60 71
0.3 16 20 24 25 15 21 24 36 45 34 42 50
G
0.5 16 17 17
0.5 11 14 17 17 11 14 17 26 33 25 31 37
0.7 8 11 13 13 8 11 13 21 27 20 24 29
0.7 13 14 14
Clevis: Rod side
C, D trunnion: U 0.3 36 46 53 56 37 47 53 78 98 76 94 109
CD
Clevis:
C, D 0.2 — 40 40 W W 0.5 26 34 39 42 27 35 40 59 74 57 70 82
0.7 21 28 32 34 22 28 32 48 61 46 58 68
0.3 — 40 40
W 0.3 82 103 116 126 81 102 115 150 150 150 – –
D
0.5 27 35 40 43 28 36 41 60 76 59 – –
Rod side
Foot: L flange: F 0.2 20 40 40
0.7 22 29 33 35 23 30 34 50 63 48 – –
W W
Rod side Head side
Foot: L flange: F flange: G 0.3 100 147 166 181 117 147 150 150 150 150 150 150
LF
BLF
0.3 20 40 40
W W W 0.5 90 113 128 139 89 112 127 150 150 150 150 150
0.5 20 40 40 0.7 76 95 107 117 75 94 107 150 150 150 150 150
W W
0.5 100 150 183 199 128 150 150 150 150 150 150 150
BLF
0.3 20 40 40 W W W
0.7 100 136 154 167 108 135 150 150 150 150 150 150
0.5 20 40 40 0.3 80 101 114 123 80 101 114 150 150 150 150 150
G
Front matter 28
Air Cylinders Model Selection 2-1
cylinder is operated.
(cm)
Mounting type Maximum stroke that can be used according to buckling strength
Operating
pressure
Mounting bracket
diagram
(MPa) 32 40 50 63 80 100 125 140 160 180 200 250 300 125 140 160
Foot: L Rod side Head side
flange: F flange: G 0.3 71 81 102 79 98 114 131 117 126 141 158 182 206 103 92 113
LF
0.3 31 35 46 34 42 50 57 49 53 60 68 79 90 45 38 47
G
0.5 23 26 34 25 31 37 42 35 38 44 50 58 66 33 27 34
0.7 19 21 27 19 24 29 34 28 30 34 40 45 53 26 22 27
Clevis: Rod side
C, D trunnion: U 0.3 67 76 96 73 91 105 122 106 118 130 146 167 190 96 83 106
CD
0.3 – – – – – – – – – – – – – – – –
U
0.5 – – – – – – – – – – – – – – – –
Head side Center
trunnion: T trunnion: T
0.7 – – – – – – – – – – – – – – – –
W CA1, CS1, CS2 series only
W
0.3 93 105 134 103 128 149 171 151 163 183 206 235 267 135 119 147
T
0.5 71 80 102 78 97 113 129 113 123 139 156 178 203 101 89 111
W W W 0.5 158 179 226 177 219 253 293 263 281 315 252 403 458 231 207 253
0.7 132 150 190 148 184 212 245 218 235 265 296 339 385 193 172 212
0.3 99 112 142 116 136 158 183 160 173 196 218 251 286 144 126 156
G
0.5 75 85 108 83 102 119 138 120 131 147 165 189 216 109 94 118
W W W 0.5 234 266 339 257 317 367 423 377 407 457 509 587 665 334 297 367
0.7 194 220 275 216 267 309 356 317 343 385 429 494 561 281 250 309
0.3 136 154 206 151 199 231 266 235 254 287 320 369 419 210 185 229
G
0.5 110 125 158 123 152 176 203 179 194 218 244 281 320 160 141 175
0.7 93 105 132 102 127 147 170 149 144 182 204 235 268 134 117 129
Front matter 29
2-1 Best Pneumatics
4
Obtain the cylinder’s air consumption and its required air volume.
400
300 0.02
How to Obtain the Required Air Volume/How to Read Graph (22) 200 6 0.015
150 0.01
Step 3 By using Graph (22), obtain the air cylinder’s required air
100
volume.
q Seek the point at which the operating pressure (diagonal
line) intersects with the cylinder stroke, and from that point, 50
perpendicularly extend a vertical line upward. 0. 0.4 0.
2
0. 0. 6 0. 0.3
Operating pressure (MPa) 8 7 5
w From the point at which it intersects with the bore size
(diagonal line) of the cylinder to be used, look sideways
(either to the right or left) to obtain the air consumption that
is required by one cycle of the air cylinder.
Example: What is the required air volume for operating a
cylinder with a bore size of 50 mm, at pressure of 0.5
MPa, and at a speed of 500 mm/s?
How to read: Operating pressure 0.5 MPa → Maximum piston
speed 500 mm/s → Bore size 50 mm → Then, a
required air volume 350 L/min (ANR) can be
obtained.
Front matter 30
Air Cylinders Model Selection 2-1
4 4
5
3 3 10
500 0 500
2 2 400 400
300 80 300
1
200 63 200
1 1
3/
150 150
4
50
100 100
1/
0.5 0.5 40
2
0.4 13 0.4
3/8 50 32 50
12
0.3 0.3 40 40
1/4
30 25 30
0.2 9 0.2
20 20 20
8 7.
15 15
10 0.1 16
5
10 10
8
6
5 0.05
2000 10
5
4 0.04 5
1500 4
3 0.03
3
4
1000
Piping length (m)
2 0.02 2
1.5 6
2.
500
5
1 0.01 400 1
300
200 0.5
0.5 0.005
0.4
0.3 100
0.8
0.6 0.7
0.4 0.5
0.2 3
0.8
0.7
0.6
0.5
0.4
0.3
0.2
∗ The piping length is the length of the steel pipe or tube that connects the cylinder with the switching valve (solenoid valve, etc.)
∗ For the dimensions (bore size and O.D.) of the steel tubing, refer to page 1902.
Front matter 31
2-1 Best Pneumatics
Conditions
Example
When the cylinder bore size is ø, its stroke is L , and load ratio is d %, full stroke time t is obtained, as an
arrow mark q, by reading the value on the abscissa over the point at which the ordinate L hits the full
stroke line (red line) of d %. Terminal velocity u is obtained, as an arrow mark w, by reading the value on
the abscissa below the point at which the ordinate L hits the terminal velocity line (blue line) of d %.
Speed
velocity
Stroke
end
(mm)
Stroke
Time (sec)
ON
SOL.OFF
Front matter 32
Air Cylinders’ Drive System Full Stroke Time & Stroke End Velocity 2-1
Speed
Stroke end
velocity
Speed 0
Stroke end
Acceleration
velocity
0 0
Supply chamber
pressure
Exhaust chamber
pressure
Stroke Stroke
0 0
Time Time
Front matter 33
2-1 Best Pneumatics
AN120 AS1201F 45
Stroke (mm)
-M5 SY3120-M5 -M5-04 70% 30%
TU0425 SYJ3120-M3 30
AN120 VQD1121-M5 AS1200 50% 10%
-M3 -M5 15
ø10 100
AS1201F 75
Stroke (mm)
SY3120-M5 -M5-04
AN120
TU0425 SYJ512-M5 50
-M5
VQZ1120-M5 AS1200
-M5 25
ø16 100
AS1201F 75
Stroke (mm)
SY3120-M5 -M5-04
AN120
TU0425 SYJ512-M5 50
-M5
VQZ1120-M5 AS1200
-M5 25
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
How
How to
to Read
Read the
the Graph
Graph Conditions
This graph shows the full stroke
time and stroke end velocity when a Pressure 0.5 MPa
As the graph shown at right, various Speed controller Meter-out, connected with cylinder
directly, needle fully opened
load ratio and full stroke time which
Load factor ((Load mass x 9.8)/Theoretical output) x 100%
corresponds to stroke and terminal
velocity are indicated for every
cylinder bore size.
Front matter 34
Air Cylinders’ Drive System Full Stroke Time & Stroke End Velocity 2-1
AS2201F 150
Stroke (mm)
SY3120-M5 -01-04
AN120
TU0425 SYJ5120-M5 100
-M5 AS2200
VQ1160-M5 70% 50% 30%
-01 50
10% 0
ø25 200
AS2201F 150
Stroke (mm)
SY3120-M5 -01-04
AN120
TU0425 SYJ5120-M5 100
-M5 AS2200
VQ1160-M5
-01 50
ø32 200
Stroke (mm)
-01 SY5120-01 -01-06
TU0604 100
AN101 SX5120-01 AS2200
-01 -01 50
ø40 200
ANB1 AS2201F 150
Stroke (mm)
-01 SY5120-01 -02-06
TU0604 100
AN101 SX5120-01 AS2200
-01 -02 50
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
When the cylinder bore size is ø, its stroke is L , and load ratio is d %, full stroke time t is obtained, as an
Example
arrow mark q, by reading the value on the abscissa over the point at which the ordinate L hits the full
stroke line (red line) of d %. Terminal velocity u is obtained, as an arrow mark w, by reading the value on
the abscissa below the point at which the ordinate L hits the terminal velocity line (blue line) of d %.
Full stroke time
Full stroke time (t )
ø
Stroke (mm)
q d% d%
Stroke (L)
Speed
velocity
Stroke
end
w Stroke
Front matter 35
2-1 Best Pneumatics
AS1201F 15
Stroke (mm)
SY3120-M5 -M5-04
AN120
TU0425 SYJ5120-M5 10
-M5 AS1200
VQ1160-M5
-M5 5
ø16 20
AS1201F 15
Stroke (mm)
SY3120-M5 -M5-04
AN120
TU0425 SYJ5120-M5 10
-M5 AS1200
VQ1160-M5
-M5 5
ø20 40
AS1201F 30
Stroke (mm)
SY3120-M5 -M5-04
AN120
TU0425 SYJ5120-M5 20
-M5 AS1200
VQ1160-M5
-M5 10
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
How
How to
to Read
Read the
the Graph
Graph Conditions
This graph shows the full stroke
time and stroke end velocity when a Pressure 0.5 MPa
As the graph shown at right, various Speed controller Meter-out, connected with cylinder
directly, needle fully opened
load ratio and full stroke time which
Load factor ((Load mass x 9.8)/Theoretical output) x 100%
corresponds to stroke and terminal
velocity are indicated for every
cylinder bore size.
Front matter 36
Air Cylinders’ Drive System Full Stroke Time & Stroke End Velocity 2-1
AS1201F 30
Stroke (mm)
SY3120-M5 -M5-04
AN120
TU0425 SYJ5120-M5 20
-M5 AS1200
VQ1160-M5
-M5 10
ø32 40
AS2201F 30
Stroke (mm)
SY3120-M5
AN120 -01-06
TU0604 SYJ5120-M5 20
-M5 AS2200
VQ1160-M5
-01 10
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
When the cylinder bore size is ø, its stroke is L , and load ratio is d %, full stroke time t is obtained, as an
Example
arrow mark q, by reading the value on the abscissa over the point at which the ordinate L hits the full
stroke line (red line) of d %. Terminal velocity u is obtained, as an arrow mark w, by reading the value on
the abscissa below the point at which the ordinate L hits the terminal velocity line (blue line) of d %.
Full stroke time
Full stroke time (t )
ø
q d% d%
Stroke (mm)
Speed
Stroke (L)
velocity
Stroke
end
w Stroke
Front matter 37
2-1 Best Pneumatics
AS2201F 75
Stroke (mm)
50%
AN101 -01-06
TU0604 SY5120-01 50
-01 AS2200
-01 30%
25
10%
0
ø50 100
AS2201F 75
Stroke (mm)
AN101 -02-06
TU0604 SY5120-01 50
-01 AS2200
-02 25
ø63 100
AS3201F 75
Stroke (mm)
AN101 -02-08
TU0805 SY5120-01 50
-01 AS3000
-02 25
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
How
How to
to Read
Read the
the Graph
Graph
Conditions
This graph shows the full stroke
time and stroke end velocity when a Pressure 0.5 MPa
As the graph shown at right, various Speed controller Meter-out, connected with cylinder
directly, needle fully opened
load ratio and full stroke time which
Load factor ((Load mass x 9.8)/Theoretical output) x 100%
corresponds to stroke and terminal
velocity are indicated for every
cylinder bore size.
Front matter 38
Air Cylinders’ Drive System Full Stroke Time & Stroke End Velocity 2-1
ø80 70%
10% 30% 50% 70%
100
AN110 75
Stroke (mm)
50%
-01 SY7120-02 AS4000
TU1065 50
AN101 SX7120-01 -03
-01 30% 25
10%
0
ø100 100
ANB1 AS5000 75
Stroke (mm)
-03 VFS41-03 -03
TU1208 50
AN30 VFR41-03 AS420
-03 -03 25
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
When the cylinder bore size is ø, its stroke is L , and load ratio is d %, full stroke time t is obtained, as an
Example
arrow mark q, by reading the value on the abscissa over the point at which the ordinate L hits the full
stroke line (red line) of d %. Terminal velocity u is obtained, as an arrow mark w, by reading the value on
the abscissa below the point at which the ordinate L hits the terminal velocity line (blue line) of d %.
Full stroke time
Full stroke time (t )
ø
q d% d%
Stroke (mm)
Speed
Stroke (L)
velocity
Stroke
end
w Stroke
Front matter 39
2-1 Best Pneumatics
Stroke (mm)
-01 SY5120-01 -01-06
TU0604 200
AN101 SX5120-01 AS2200 70% 50% 30%
-01 -01 100
10%
0
ø40 400
Stroke (mm)
-01 SY5120-01 -02-06
TU0604 200
AN101 SX5120-01 AS2200
-01 -02 100
ø50 400
Stroke (mm)
-01 SY5120-01 -02-08
TU0805 200
AN101 SX5120-01 AS3000
-01 -02 100
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
How
How to
to Read
Read the
the Graph
Graph Conditions
This graph shows the full stroke
time and stroke end velocity when a Pressure 0.5 MPa
As the graph shown at right, various Speed controller Meter-out, connected with cylinder
directly, needle fully opened
load ratio and full stroke time which
Load factor ((Load mass x 9.8)/Theoretical output) x 100%
corresponds to stroke and terminal
velocity are indicated for every
cylinder bore size.
Front matter 40
Air Cylinders’ Drive System Full Stroke Time & Stroke End Velocity 2-1
AN110 300
Stroke (mm)
-01 SY7120-02 AS4000
TU1065 200
AN101 SX7120-02 -03
-01 100
70% 50% 30% 10% 0
ø80 400
Stroke (mm)
-02 VFS31-02 -02
TU1065 200
AN20 VFR31-02 AS420
-02 -02 100
ø100 400
Stroke (mm)
-03 VFS41-03 -03
TU1208 200
AN30 VFR41-03 AS420
-03 -03 100
0
Solenoid valve Speed 0 100 200 300 400 500 600 700 800 900 1000
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
When the cylinder bore size is ø, its stroke is L , and load ratio is d %, full stroke time t is obtained, as an
Example
arrow mark q, by reading the value on the abscissa over the point at which the ordinate L hits the full
stroke line (red line) of d %. Terminal velocity u is obtained, as an arrow mark w, by reading the value on
the abscissa below the point at which the ordinate L hits the terminal velocity line (blue line) of d %.
Full stroke time
Full stroke time (t )
ø
q d% d%
Stroke (mm)
Speed
Stroke (L)
velocity
Stroke
end
w Stroke
Front matter 41
2-1 Best Pneumatics
Stroke (mm)
-03 VFR3100-03 -02 30%
SGP10A 400
AN30 VEX3320-03 AS5000
10%
-03 -02 200
ø140 800
Stroke (mm)
-03 VFR3100-03 -03
SGP10A 400
AN30 VEX3320-03 AS5000
-03 -03 200
ø160 800
ANB1 600
Stroke (mm)
-04 VFR4100-04 AS420
SGP10A 400
AN40 VEX3320-04 -03
-04 200
0
Solenoid valve Speed 0 50 100 150 200 250 300 350 400 450 500
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
How
How to
to Read
Read the
the Graph
Graph Conditions
This graph shows the full stroke
time and stroke end velocity when a Pressure 0.5 MPa
As the graph shown at right, various Speed controller Meter-out, connected with cylinder
directly, needle fully opened
load ratio and full stroke time which
Load factor ((Load mass x 9.8)/Theoretical output) x 100%
corresponds to stroke and terminal
velocity are indicated for every
cylinder bore size.
Front matter 42
Air Cylinders’ Drive System Full Stroke Time & Stroke End Velocity 2-1
ANB1 600
Stroke (mm)
-04 30%
SGP15A VEX3500-04 AS420
400
AN40 VP3145-03 -03 10%
-04 200
ø200 800
ANB1 600
Stroke (mm)
-04 AS420
SGP15A VEX3500-04 400
AN40 VP3145-03 -04
-04 200
ø250 800
ANB1 600
Stroke (mm)
-06 VEX3500-06 AS600
SGP20A 400
AN500 VP3145-04 -10
-06 200
ø300 800
ANB1 600
Stroke (mm)
-10 VEX3500-10 AS600
SGP20A 400
AN600 VP3145-06 -10
-10 200
0
Solenoid valve Speed 0 50 100 150 200 250 300 350 400 450 500
Silencer Tubing (2 position) controller
Stroke end velocity (mm/s)
Applicable model
For details corresponding to each various condition, make the use of “Model Selection Software” on SMC website for your decision.
When the cylinder bore size is ø, its stroke is L , and load ratio is d %, full stroke time t is obtained, as an
Example
arrow mark q, by reading the value on the abscissa over the point at which the ordinate L hits the full
stroke line (red line) of d %. Terminal velocity u is obtained, as an arrow mark w, by reading the value on
the abscissa below the point at which the ordinate L hits the terminal velocity line (blue line) of d %.
Full stroke time
Full stroke time (t )
ø
q d% d%
Stroke (mm)
Speed
Stroke (L)
velocity
Stroke
end
w Stroke
Front matter 43
Best Pneumatics 2-1
Technical Data 1: Bore Size Selection··················· P.1898
Technical Data
qDouble Acting Cylinder ··························································································· P.1898
wSingle Acting Cylinder ····························································································· P.1899
eCushion··························································································································· P.1901
1897
Technical Data 1:
Bore Size Selection
CJ2 Series CM2 Series
Data 1 Bore Size Selection
1898
Bore Size Selection
(N) CQ2 Series/Single Acting, Spring Return (N) CQ2 Series/Single Acting, Spring Extend (N)
Bore size Spring reaction force (N) Bore size Stroke Spring reaction force (N) Bore size Stroke Spring reaction force (N)
Series
(mm) Outlet Inlet (mm) (mm) Outlet Inlet (mm) (mm) Outlet Inlet
2.5 1.13 0.64 5 13 8.6 5 11 2.9
CJ1 Note) 12 12
4 3.04 1.47 10 13 3.9 10 9.7 2.8
4 2.80 1.00 5 15 10.3 5 20 3.9
16 16
6 3.92 1.42 10 15 5.9 10 20 3.9
CJP Note)
10 5.98 2.45 5 15 10 5 27 5.3
20 20
15 10.8 4.41 10 15 5.9 10 27 5.9
6 3.72 1.77 5 20 16 5 29 9.8
CJ2 Note) 25 25
10 6.86 3.53 10 20 11 10 29 9.8
CVJ3∗
16 14.2 6.86 5 30 23 5 29 20
32 32
∗ Use the same spring for the spring return type. 10 30 16 10 29 20
∗ CVJ3: ø10, ø16 only. 5 30 13 5 29 20
Note) The spring reaction force is the same for each 40 40
standard stroke. 10 39 21 10 29 20
10 50 30 10 83 24
50 50
20 54 24 20 83 24
When the spring is set When the spring is contracted When the spring is set When the spring is contracted
in the cylinder by supplying air in the cylinder by supplying air
Technical
Data
1899 A
Technical Data 1:
Bore Size Selection
Data 1 Bore Size Selection
CVM3 Series
CU Series/Single Acting, Spring Return (N) CM2 Series (N) CG1 Series (N)
Bore size Stroke Spring reaction force (N) Bore size Stroke Spring reaction force (N) Bore size Stroke Spring reaction force (N)
(mm) (mm) Outlet Inlet (mm) (mm) Outlet Inlet (mm) (mm) Outlet Inlet
5 3.5 2.9 25 24 25 24
6 10 3.5 2.2 50 7.8 50 7.8
15 3.5 1.6 75 17 20 75 39 17
20 39
5 6.9 5.0 100 9.8 100 9.8
10 10 6.9 3.0 125 14 125 14
15 6.9 3.3 150 8.8 25 30
5 14.7 10.3 25 30 50 14
16 10 14.7 5.9 50 14 75 24
15 14.7 9.3 75 25 25 100 47 17
25 47
5 15 11 100 17 125 21
20 10 15 6 125 21 150 24
15 21 10 150 16 200 17
5 21 16 25 41 25 40
25 10 21 11 50 15 50 15
15 28 14 75 31 75 31
5 30 26 100 20 32 100 67 20
32 67
32 10 30 16 125 26 125 25
15 34 17 150 18 150 31
∗ Use the same spring for the spring return type. 175 25 200 20
200 20 25 50
25 50 50 24
50 24 75 36
75 36 40 100 76 24
100 24 125 32
125 32 150 36
40 76
150 24 200 24
175 30
200 24
225 29
250 24
When the spring is set When the spring is When the spring is set When the spring is
in the cylinder contracted by supplying air in the cylinder contracted by supplying air
A 1900
Bore Size Selection
Kinetic energy absorbable by the cushion mechanism is the table 63 3.4 11.8 4.9
at right. When the values are exceeded, following countermea- 80 5.9 17.3 11.8
sures are required like using a bigger bore size cylinder or mount- 100 9.9 15.8 16.7
ing an external stopper, etc.
CA2, CS1, CS2 Series
R: Rod side, H: Head side
RQ Series MB Series
Bore size Effective cushion length Kinetic energy absorbable Effective cushion length Kinetic energy absorbable
Bore size
(mm) (mm) (J) (mm) (J)
(mm)
20 5.8 0.40 32 18.8 2.2
25 6.1 0.63 40 18.8 3.4
32 6.6 1.00
50 21.3 5.9
40 6.6 1.60
63 21.3 11
50 7.1 2.50
80 30.3 20
63 7.0 4.00
100 29.3 29
80 7.5 6.40
Technical
125 R: 31.4 H: 29.4 45
100 8.0 10.00
R: Rod side, H: Head side Data
1901
Technical Data 2:
Air Consumption and Required Air Volume
Data 2 Air Consumption and Required Air Volume
The air consumption is the volume of air that is consumed in the cylinder or in the piping between the cylinder and the switching valve during
the reciprocal movement of an air cylinder. It is necessary for selecting a compressor and for calculating the running cost.
The required air volume is the volume of air that is required for operating the cylinder at a specified speed, and it is necessary for selecting
the diameter ofthe piping upstream from switching valve or the FRL equipment.
1902
Technical Data 3:
Theoretical Output Table
Data 3 Theoretical Output
Applicable cylinder: CJ2, CM2, CG1, CA2, MB, CS1, CS2 Series
CJ2 Series
(ø6 to ø16)
CM2 Series CG1 Series CA2 Series MB Series CS1 Series CS2 Series
(ø20 to ø40) (ø20 to ø100) (ø40 to ø100) (ø32 to ø125) (ø125 to ø300) (ø125 to ø160)
-20
-30 Ps [MPa]
0.7
0.6
0.5
0.4
-40
-50
None-condensation
zone
-60
0 20 40 60 80 100 120 140 160
Volume ratio Kv
0
Enlarged view
Inlet air: Atmospheric pressure dew point °C
-5
-10
-20
Ps [MPa]
-25 0.7
0.6
0.5 0.4
-30
-35
-40
-50
0 5 10 15 20
Volume ratio Kv
Refer to a separate catalog, “Condensation Measures of Pneumatic Systems” (Refer to the SMC website.) for the details of measures.
Condensation control can also be determined based on SMC’s Pneumatic Equipment Model Selection Program Ver. 3.5.