PREVENTATIVE MAINTENANCE INSTRUCTIONS

Preventative Maintenance Schedule


To insure the proper operation of the PODS Calibration and Verification machine, the following
preventative maintenance actions should be followed.

Component Description Action Frequency


Mechanical Svstem
Horizontal slide bearings Lubricate with grease 6
months/1000
hours
Horizontal slide rods Check for abnormal wear-replace 12
months/2000
hours
Vertical slide rods Check for abnormal wear-replace 12
months/2000
hours
Vertical slide bearings Check for abnormal wear-replace 12
months/2000
hours
Cylinder clevis cotter pins Check for damage/missing 12
replace months/2000
hours
Cylinder rod nuts Check for tightness - tighten 12
months/2000
hours
Pneumatic System
Filter/regulator Drain bowl 2 weeks / 100
hours
Filter/regulator Change filter 12
months/2000
hours
Air Conditioner Clean or Change filter 30 days

Test Harnesses
Visually inspect test harness for bent or broken pins. Clean contact pins with approved electrical
contact cleaner as needed. Inspect cable jacket for wear.

Refer to the individual component literature for maintenance on other system


components.