RADIOGRAPHIC EXAMINATION REPORT

M/s. : SCHUTTE MEYER ASHWATH ALLOYS PVT LTD Page 1 of 3

Customer : L&T VALVES LIMITED Report No Page 1 of


: TIES/SMA/1967 3
- R0

Description : 10"150 GLV BODY Report Date : :14/08/2015


Drawing No : LT322100R REV2 Radiography No : SMA2377
Grade : WCB Heat No : B3145

Ir-192 Source Strength :20Ci Source Size :2.7DIAX1.5 Date of Test : 01/08/2015
Film Type : AGFA D7 Evaluation Reference : E446
Pb Screen Thickness : 0.1MM BACK 0.15MM Procedure Reference : CSP-N001 REV-2
IQI : ASTM Acceptance Standard : ASME SEC III-NB/NC
Shooting Technique : SWSI
Area of Coverage : 100% AREA
Technique Sheet No :
IQI
Sl.
No Location Source Thickness SFD Designation Sensitivity Density Film Size Findings * Classi Remarks
(mm) Inch Inchs fication
1 L-L1 Ir - 192 30 9 10F/10 2-4T 2.9-3.2 12 X 4 A/B I Acceptable
2 L1-L2 Ir - 192 30 9 10F/10 2-4T 3.3-3.5 12 X 4 B I Acceptable
3 L2-L3 Ir - 192 30 9 10F/10 2-4T 3.2-3.5 12 X 4 B I Acceptable
4 L3-L Ir - 192 30 9 10F/10 2-4T 3.4-3.6 12 X 4 B I Acceptable
5 R-R1 Ir - 192 30 9 10F/10 2-4T 3.4-3.7 12 X 4 A I Acceptable
6 R1-R2 Ir - 192 30 9 10F/10 2-4T 2.7-3.0 12 X 4 B I Acceptable
7 R2-R3 Ir - 192 30 9 10F/10 2-4T 2.5-2.8 12 X 4 B I Acceptable
8 R3-R Ir - 192 30 9 10F/10 2-4T 2.9-3.2 12 X 4 B I Acceptable
9 L4 Ir - 192 60 12 40F 2-2T 2.4-2.6 6X3 A II Acceptable
10 L5 Ir - 192 60 12 40F 2-2T 2.7-3.0 6X3 B I Acceptable
11 L6 Ir - 192 60 12 40F 2-2T 2.5-2.9 6X3 B I Acceptable
12 L7 Ir - 192 60 12 40F 2-2T 2.8-3.4 6X3 B I Acceptable
13 R4 Ir - 192 60 12 40F 2-2T 2.5-2.8 6X3 A/B I Acceptable
14 R5 Ir - 192 60 12 40F 2-2T 2.3-2.7 6X3 B I Acceptable
15 R6 Ir - 192 60 12 40F 2-2T 2.1-2.5 6X3 NSD - Acceptable
16 R7 Ir - 192 60 12 40F 2-2T 2.1-2.5 6X3 B I Acceptable
17 F-F1 Ir - 192 40 6 25 2-2T 2.9-3.4 8X6 A/B I Acceptable
18 F1-F2 Ir - 192 40 6 25 2-2T 2.9-3.4 8X6 B I Acceptable
19 F2-F3 Ir - 192 40 6 25 2-2T 3.5-3.9 8X6 B I Acceptable
20 F3-F4 Ir - 192 40 6 25 2-2T 3.5-3.9 8X6 B I Acceptable
21 F4-F5 Ir - 192 40 6 25 2-2T 3.1-3.6 8X6 B I Acceptable
22 F5-F6 Ir - 192 40 6 25 2-2T 2.2-2.5 8X6 B I Acceptable
23 F6-F7 Ir - 192 40 6 25 2-2T 3.6-3.9 8X6 B I Acceptable

*A : Gas Hole ; B : Inclusion ; CA,CB,CC,CD : Shrinkage ; D : Crack ; E : Hot Tear ; F : Insert ; NSD : No Significant Defect ;

For TEST RAY'S INSPECTION AND


ENGINEERING SERVICES

F.ARUN VICTOR
LEVEL II RT SUPPLIER CUSTOMER EXTERNAL INSPECTOR
TEST RAY'S INSPECTION AND ENGINEERING SERVICES
SF.No. 413/3B,MOPPERIPALAYAM(POST),, COIMBATORE., Pincode :641 659.
Phone :0421 - 3269845,96009 44001,02,03, Mail :tiesndt@gmail.com , CST No. :1028619 Dt.01.09.2009

RADIOGRAPHIC EXAMINATION REPORT

M/s. : SCHUTTE MEYER ASHWATH ALLOYS PVT LTD Page 2 of 3

Customer : L&T VALVES LIMITED Report No Page 2 of


: TIES/SMA/1967 3
- R0

Description : 10"150 GLV BODY Report Date : :14/08/2015


Drawing No : LT322100R REV2 Radiography No : SMA2377

Grade : WCB Heat No : B3145

Ir-192 Source Strength :20Ci Source Size :2.7DIAX1.5 Date of Test : 01/08/2015
Film Type : AGFA D7 Evaluation Reference : E446
Pb Screen Thickness : 0.1MM BACK 0.15MM Procedure Reference : CSP-N001 REV-2
IQI : ASTM Acceptance Standard : ASME SEC III-NB/NC
Shooting Technique : SWSI
Area of Coverage : 100% AREA
Technique Sheet No :
IQI
Sl.
No Location Source Thickness SFD Designation Sensitivity Density Film Size Findings * Classi Remarks
(mm) Inch Inchs fication
24 F7-F8 Ir - 192 40 6 25 2-2T 3.5 - 3.9 8X6 B I Acceptable
25 F8-F9 Ir - 192 40 6 25 2-2T 3.2-3.5 8X6 CB II Acceptable
26 F9-F Ir - 192 40 6 25 2-2T 2.7-3.4 8X6 A/CB I/II Acceptable
27 TN-TN1 Ir - 192 15 12 12 2-4T 2.6-2.9 8X4 A/B I Acceptable
28 TN1-TN2 Ir - 192 15 12 12 2-4T 3.0-3.3 8X4 B I Acceptable
29 TN2-TN3 Ir - 192 15 12 12 2-4T 3.1-3.5 8X4 B I Acceptable
30 TN3-TN4 Ir - 192 15 12 12 2-4T 3.1-3.5 8X4 A I Acceptable
31 TN4-TN5 Ir - 192 15 12 12 2-4T 2.8-3.0 8X4 A/B I Acceptable
32 TN5-TN6 Ir - 192 15 12 12 2-4T 3.0-3.5 8X4 A I Acceptable
33 TN6-TN7 Ir - 192 15 12 12 2-4T 3.3-3.5 8X4 A/B I Acceptable
34 TN7-TN Ir - 192 15 12 12 2-4T 2.4-2.7 8X4 B I Acceptable
35 S Ir - 192 35 8 25F 2-2T 2.4-2.7 10 X 4 B I Acceptable
36 S1 Ir - 192 35 8 25F 2-2T 2.8-3.2 10 X 4 B I Acceptable
37 S2 Ir - 192 35 8 25F 2-2T 3.0-3.6 10 X 4 B II Acceptable
38 S3 Ir - 192 35 8 25F 2-2T 2.5-2.8 10 X 4 A II Acceptable
39 X-X1 Ir - 192 15 8 10F/12 2-4T 2.5-2.7 10 X 8 A/B I Acceptable
40 X1-X2 Ir - 192 15 8 10F/12 2-4T 2.7-2.9 10 X 8 B I Acceptable
41 X3-X4 Ir - 192 15 8 10F/12 2-4T 3.5-3.9 10 X 8 B I Acceptable
42 X4-X5 Ir - 192 15 8 10F/12 2-4T 2.8-3.0 10 X 8 A/B I Acceptable
43 Y-Y1 Ir - 192 15 8 10F/12 2-4T 2.4-2.9 10 X 8 A/B I/II Acceptable
44 Y1-Y2 Ir - 192 15 8 10F/12 2-4T 2.2-2.5 10 X 8 A/B I Acceptable
45 Y3-Y4 Ir - 192 15 8 10F/12 2-4T 2.4-2.9 10 X 8 CB II Acceptable
46 Y4-Y5 Ir - 192 15 8 10F/12 2-4T 2..2-2.5 10 X 8 A/B I Acceptable

*A : Gas Hole ; B : Inclusion ; CA,CB,CC,CD : Shrinkage ; D : Crack ; E : Hot Tear ; F : Insert ; NSD : No Significant Defect ;

For TEST RAY'S INSPECTION AND


ENGINEERING SERVICES

F.ARUN VICTOR
LEVEL II RT SUPPLIER CUSTOMER EXTERNAL INSPECTOR
TEST RAY'S INSPECTION AND ENGINEERING SERVICES
SF.No. 413/3B,MOPPERIPALAYAM(POST),, COIMBATORE., Pincode :641 659.
Phone :0421 - 3269845,96009 44001,02,03, Mail :tiesndt@gmail.com , CST No. :1028619 Dt.01.09.2009

RADIOGRAPHIC EXAMINATION REPORT

M/s. : SCHUTTE MEYER ASHWATH ALLOYS PVT LTD Page 3 of 3

Customer : L&T VALVES LIMITED Report No Page 3 of


: TIES/SMA/1967 3
- R0

Description : 10"150 GLV BODY Report Date : :14/08/2015


Drawing No : LT322100R REV2 Radiography No : SMA2377
Grade : WCB Heat No : B3145

Ir-192 Source Strength :20Ci Source Size :2.7DIAX1.5 Date of Test : 01/08/2015
Film Type : AGFA D7 Evaluation Reference : E446
Pb Screen Thickness : 0.1MM BACK 0.15MM Procedure Reference : CSP-N001 REV-2
IQI : ASTM Acceptance Standard : ASME SEC III-NB/NC
Shooting Technique : SWSI
Area of Coverage : 100% AREA
Technique Sheet No :
IQI
Sl.
No Location Source Thickness SFD Designation Sensitivity Density Film Size Findings * Classi Remarks
(mm) Inch Inchs fication
47 1-2 Ir - 192 15 8 10F/12 2-4T 2.6-3.0 10 X 8 A/B II Acceptable
48 2-3 Ir - 192 15 8 10F/12 2-4T 2.6-3.0 10 X 8 A/B I/II Acceptable
49 3-4 Ir - 192 15 8 10F/12 2-4T 3.0-3.6 10 X 8 A/B I/II Acceptable
50 5-6 Ir - 192 15 8 10F/12 2-4T 2.7-3.0 10 X 8 A/B I Acceptable
51 6-7 Ir - 192 15 8 10F/12 2-4T 3.3-3.6 10 X 8 A II Acceptable
52 7-8 Ir - 192 15 8 10F/12 2-4T 3.0-3.4 10 X 8 A/B I Acceptable
53 G1 Ir - 192 25 8 20F/25 2-2T 2.6-3.2 10 X 6 A/B I Acceptable
54 G2 Ir - 192 25 8 20F/25 2-2T 2.6-3.2 10 X 6 A/B I/II Acceptable
55 J1 Ir - 192 20 4 15F 2-2T 3.0-3.5 10 X 4 B II Acceptable
56 J2 Ir - 192 20 4 15F 2-2T 3.2-3.8 10 X 4 B I Acceptable

Total Area ( Ir 192 ) 2744 Sq.Inchs Total No of Film ( Ir 192) 56

CASTINGS ACCEPTED UNDER LEVEL II


*A : Gas Hole ; B : Inclusion ; CA,CB,CC,CD : Shrinkage ; D : Crack ; E : Hot Tear ; F : Insert ; NSD : No Significant Defect ;

For TEST RAY'S INSPECTION AND


ENGINEERING SERVICES

F.ARUN VICTOR
LEVEL II RT SUPPLIER CUSTOMER EXTERNAL INSPECTOR