You are on page 1of 1

LPO736735 (Note):

1.Vessel to comply with applicable statutory regulation.


2. Designed draft is subject to freeboard assignment.

LPO736747: Efficient bulwark/guard rails


are to be fitted on all exposed parts of
freeboard deck at least 1 m from deck.

LPO736741: Supporting structure


IWO crane boom to be clarified.

3)

LPO736757
LPO736737: Access to main engine room & store to be protected Pending drawing structure reinforcement IWO:
with coaming min height 600mm. 1) bollards
2) anchoring equipment
3) propeller shaft bracket
4) harbour & main generator seating

23918A
23927K
23929M
23930N
23931P
23932Q
BUREAU VERITAS Section ....................
VU avec observations
4) Singapore, 14-Mar-2013

[Electronic document]
The plan approval office
M.RAHIM / S.C.KONG

4)

LPO736739: At least 2 widely separated & ready means of


escape are to be provided at engine room.

SEE TECH. COMMENT SPO/13/01049/MRA


DATED 14/03/2013.