You are on page 1of 171

STANDARD STANDARD OUT

ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

1 EXCAVATION AND EARHWORK

Bulk excavarion piled or truckloaded, no halul


1.1 included

1.1.1 For ORDINARY SOIL


Backhoe, hydraulic, crawler mounted
1.1.1.1. 0.765m3 cap m3 EX-1 88.O
1.1.1.2. 1.15m3 cap m3 EX-2 115.O
1.1.1.3. 1.53m3 cap m3 EX-3 145.O
1.1.1.4. 2.68m3 cap m3 EX-4 295.O
Backhoe, hydraulic, wheel mounted
1.1.1.5. 0.38m3 cap m3 EX-5 45.O
1.1.1.6. 0.57m3 cap m3 EX-A6 68.O
Clamshell
1.1.1.7. 0.38m3 cap m3 EX-7 64.O
1.1.1.8. 0.765m3 cap m3 EX-8 11O.O
Dozer
1.1.1.9. 15m haul, 75H.P m3 EX-9 145.O
1.1.1.10. 15m haul, 140HP m3 EX-9A 21O.O
1.1.1.11. 15m haul, 200HP m3 EX-9B 27O.O
1.1.1.12. 15m haul, 300HP m3 EX-1O 44O.O
Dragline
1.1.1.13. 0.57m3 cap m3 EX-11 195.O
1.1.1.14. 1.15m3 cap m3 EX-12 36O.O
Front end loader, track mounted,
1.1.1.15. 1.15m3 cap m3 EX-13 15O.O
1.1.1.16. 1.91m3 cap m3 EX-15 2OO.O
1.1.1.17. 2.68m3 cap m3 EX-16 275.O
1.1.1.18. 3.44m3 cap m3 EX-17 34O.O
Front end loader, wheel mounted
1.1.1.19. 0.57m3 cap m3 EX-18 79.O
1.1.1.20. 1.15m3 cap EX-19 14O.O
1.1.1.21. 1.72m3 cap m3 EX-20 175.O
1.1.1.22. 3.83m3 cap m3 EX-21 325.O
Gradall
1.1.1.23. 762mm.bucket, 0.38m3 cap m3 EX-22 115.O
1.1.1.24. 1219mm.bucket, 0.77m3 cap m3 EX-23 17O.O
Scrapers, towed, 1/4 push dozer
1.1.1.25. 7.65m3 capacity 500m. Haul m3 EX-25 27O.O
1.1.1.26. 7.65m3 capacity 500m. Haul m3 EX-25 16O.O
1.1.1.27. 11.48m3 capacity 1500m. Haul m3 EX-26 4OO.O
1.1.1.28. 11.48m3 capacity 1500m. Haul m3 EX-26 24O.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

Self-propelled scrapers, 1/4 push dozer


1.1.1.29 11.48m3 capacity 500m. Haul m3 EX-27 455.O
1.1.1.30 11.48m3 capacity 1500m. Haul m3 EX-27 27O.O
1.1.1.31 19.1m3 capacity 500m. Haul m3 EX-28 6O5.O
1.1.1.32 19.1m3 capacity 1500m. Haul m3 EX-28 3OO.O
Elevating scrapers, 1/4 push dozer,
1.1.1.33 7.65m3 , 500m. Haul m3 EX-29 28O.O
1.1.1.34 7.65m3 . 1500m. Haul m3 EX-29 17O.O
1.1.1.35 15.3m3 capacity 500m. Haul m3 EX-30 445.O
1.1.1.36 15.3m3 capacity 1500m. Haul m3 EX-30 335.O
Shovel
1.1.1.37 0.38m3 cap m3 EX-31 14O.O
1.1.1.38 0.57m3 cap m3 EX-32 23O.O
1.1.1.39 0.77m3 cap m3 EX-33 275.O
1.1.1.40 1.15m3 cap m3 EX-34 415.O
Multiplying factors
For SOFT SOIL OR SAND Daily output to be
1.1.2 multiplied by 1.1
For HEAVY SOIL OR STIFF CLAY Daily output
1.1.3 to be multiplied by O.6
For WET EXCAVATION With clamshell or
1.1.4 dragline Daily output to be multiplied by O.5
For WET EXCAVATION With all other equipment
1.1.5 Daily output to be multiplied by O.6
1.2 Excavation of trench or continous footing

1.2.1 In ordinary soil


1.2.1 1.00m deep, 0.29m3 cap. m3 EX - 35 93.O
1.2.1 1.00m deep, 0.38m3 cap. m3 EX - 36 125.O
1.2.3 1.00m deep, 0.48m3 cap. m3 EX - 37 13O.O
1.2.4 1.00m deep, 0.57m3 cap. m3 EX - 6 15O.O
1.2.5 1.00m deep, 0.75m3 cap. m3 EX - 1 2OO.O
1.2.6 1.00m deep, 0.96m3 cap. m3 EX - 38 255.O
1.2.7 1.00m deep, 1.15m3 cap. m3 EX - 2 325.O
1.2.8 1.00m deep, 1.50m3 cap. m3 EX - 3 395.O
1.2.9 1.00m deep, 1.90m3 cap. m3 EX - 39 435.O
1.2.10 1.00m deep, 2.68m3 cap. m3 EX - 4 64O.O
1.2.11 1.25m deep, 0.29m3 cap. m3 EX - 35 75.O
1.2.12 1.25m deep, 0.38m3 cap. m3 EX - 36 1O5.O
1.2.13 1.25m deep, 0.48m3 cap. m3 EX - 37 135.O
1.2.14 1.25m deep, 0.57m3 cap. m3 EX -6 16O.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

1.2.15 1.25m deep, 0.75m3 cap. m3 EX - 1 21O.O


1.2.16 1.25m deep, 0.96m3 cap. m3 EX - 38 265.O
1.2.17 1.25m deep, 1.15m3 cap. m3 EX - 2 345.O
1.2.18 1.25m deep,1.50m3 cap. m3 EX - 3 415.O
1.2.19 1.25m deep, 1.90m3 cap. m3 EX - 39 53O.O
1.2.20 1.25m deep, 2.68m3 cap. m3 EX - 4 675.O
1.2.21 1.50m deep, 0.29m3 cap. m3 EX - 35 65.O
1.2.22 1.50m deep, 0.38m3 cap. m3 EX - 36 88.O
1.2.23 1.50m deep, 0.48m3 cap. m3 EX - 37 11O.O
1.2.24 1.50m deep, 0.57m3 cap. m3 EX - 6 135.O
1.2.25 1.50m deep, 0.75m3 cap. m3 EX - 1 19O.O
1.2.26 1.50m deep, 0.96m3 cap. m3 EX - 38 225.O
1.2.27 1.50m deep, 1.15m3 cap. m3 EX - 2 32O.O
1.2.28 1.50m deep, 1.50m3 cap. m3 EX - 3 39O.O
1.2.29 1.50m deep, 1.90m3 cap. m3 EX - 39 46O.O
1.2.30 1.50m deep, 2.68m3 cap. m3 EX - 4 585.O
1.2.31 2.00m deep, 0.29m3 cap. m3 EX - 35 66.O
1.2.32 2.00m deep, 0.38m3 cap. m3 EX - 36 85.O
1.2.33 2.00m deep, 0.48m3 cap. m3 EX - 37 1O5.O
1.2.34 2.00m deep, 0.57m3 cap. m3 EX - 6 13O.O
1.2.35 2.00m deep, 0.75m3 cap. m3 EX - 1 175.O
1.2.36 2.00m deep, 0.96m3 cap. m3 EX - 38 22O.O
1.2.37 2.00m deep, 1.15m3 cap. m3 EX - 2 295.O
1.2.38 2.00m deep,1.50m3 cap. m3 EX - 3 365.O
1.2.39 2.00m deep, 1.90m3 cap. m3 EX - 39 445.O
1.2.40 2.00m deep, 2.68m3 cap. m3 EX - 4 57O.O
1.2.41 2.50m deep, 0.29m3 cap. m3 EX - 35 85.O
1.2.42 2.50m deep, 0.38m3 cap. m3 EX - 36 115.O
1.2.43 2.50m deep, 0.48m3 cap. m3 EX - 37 14O.O
1.2.44 2.50m deep, 0.57m3 cap. m3 EX - 6 125.O
1.2.45 2.50m deep, 0.75m3 cap. m3 EX - 1 225.O
1.2.46 2.50m deep, 0.96m3 cap. m3 EX - 38 285.O
1.2.47 2.50m deep, 1.15m3 cap. m3 EX - 2 38O.O
1.2.48 2.50m deep, 1.50m3 cap. m3 EX - 3 47O.O
1.2.49 2.50m deep, 1.90m3 cap. m3 EX - 39 6OO.O
1.2.50 2.50m deep, 2.68m3 cap. m3 EX - 4 78O.O
1.2.51 3.00m deep, 0.29m3 cap. m3 EX - 35 55.O
1.2.52 3.00m deep, 0.38m3 cap. m3 EX - 36 79.O
1.2.53 3.00m deep, 0.48m3 cap. m3 EX - 37 1O5.O
1.2.54 3.00m deep, 057m3 cap. m3 EX - 6 125.O
1.2.55 3.00m deep, 0.75m3 cap. m3 EX - 1 155.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

1.2.56 3.00m deep, 0.96m3 cap. m3 EX - 38 21O.O


1.2.57 3.00m deep, 1.15m3 cap. m3 EX - 2 255.O
1.2.58 3.00m deep, 1.50m3 cap. m3 EX - 3 325.O
1.2.59 3.00m deep, 1.90m3 cap. m3 EX - 39 41O.O
1.2.60 3.00m deep, 2.60m3 cap. m3 EX - 4 575.O
1.2.61 3.50m deep, 0.75m3 cap. m3 EX - 1 145.O
1.2.62 3.50m deep, 0.96m3 cap. m3 EX - 38 185.O
1.2.63 3.50m deep, 1.15m3 cap. m3 EX - 2 24O.O
1.2.64 3.50m deep, 1.50m3 cap. m3 EX - 3 31O.O
1.2.65 3.50m deep, 1.90m3 cap. m3 EX - 39 4O5.O
1.2.66 3.50m deep, 2.68m3 cap. m3 EX - 4 575.O
1.2.67 4.00m deep, 0.75m3 cap. m3 EX - 1 145.O
1.2.68 4.00m deep, 0.96m3 cap. m3 EX - 38 18O.O
1.2.69 4.00m deep, 1.15m3 cap. m3 EX - 2 215.O
1.2.70 4.00m deep, 1.50m3 cap. m3 EX - 3 285.O
1.2.71 4.00m deep, 1.96m3 cap. m3 EX - 39 365.O
1.2.72 4.00m deep, 2.68m3 cap. m3 EX - 4 5O5.O
1.2.73 4.50m deep, 0.75m3 cap. m3 EX - 1 13O.O
1.2.74 4.50m deep, 0.96m3 cap. m3 EX - 38 17O.O
1.2.75 4.50m deep, 1.15m3 cap. m3 EX - 2 2OO.O
1.2.76 4.50m deep, 1.50m3 cap. m3 EX - 3 26O.O
1.2.77 4.50m deep, 1.90m3 cap. m3 EX - 39 33O.O
1.2.78 4.50m deep, 2.68m3 cap. m3 EX - 4 485.O
1.2.79 6.00m deep, 0.75m3 cap. m3 EX - 1 12O.O
1.2.80 6.00m deep, 0.96m3 cap. m3 EX - 38 145.O
1.2.81 6.00m deep, 1.15m3 cap. m3 EX - 2 175.O
1.2.82 6.00m deep,1.50m3 cap. m3 EX - 3 225.O
1.2.83 6.00m deep,1.90m3 cap. m3 EX - 39 29O.O

1.2.84 6.00m deep, 2.68m3 cap. Multiplying factors m3 EX - 4 59O.O


FOR SOFT SOIL OR SAND Daily output to be
1.2.2 multiplied by 1.2
FOR HEAVY SOIL OR STIFF CLAY Daily output
1.2.3 to be multiplied by O.6
FOR WET EXCAVATION with all other equipment
1.2.4 Daily output to be multiplied by O.7

1.3 Excavation of utility Trench Ordinary soil


Trenching with chain trencher, 12H.P,
Operator walking
1.3.1 100mm wide trench, 300mm. Deep m EX - 40 14O.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
1.3.2 100mm wide trench, 450mm. Deep m3 EX - 40 135.O
1.3.3 " " " " , 600mm. " m3 EX - 40 125.O

1.3.4 150mm wide trench, 300mm. Deep m3 EX - 40 115.O


1.3.5 " " " " , 450mm. " m3 EX - 40 1O5.O
1.3.6 " " " " , 600mm. " m3 EX - 40 97.O
1.3.7 " " " " , 900mm. " m3 EX - 40 9O.O
1.3.8 200mm wide trench, 300mm. Deep m3 EX - 40 84.O
1.3.9 200mm wide trench, 450mm. Deep m3 EX - 40 7O.O
1.3.10 200mm wide trench, 600mm. Deep m3 EX - 40 62.O
1.3.11 200mm wide trench, 900mm. Deep m3 EX - 40 53.O

Trenching with chain trencher, 40 H.P,


Operator riding
1.3.25 100mm wide trench & backfill, 300mm. Deep m3 EX - 41 195.O
1.3.26 " " " " , 450mm. " m3 EX - 41 16O.O
1.3.27 " " " " , 600mm. " m3 EX - 41 155.O
1.3.28 " " " " , 900mm. " m3 EX - 41 145.O
1.3.29 " " " " , 120mm. " m3 EX - 41 12O.O
1.3.30 " " " " , 1500mm. " m3 EX - 41 1O5.O
1.3.31 150mm wide trench & backfill, 300mm. Deep m3 EX - 41 165.O
1.3.32 " " " " , 450mm. " m3 EX - 41 155.O
1.3.33 " " " " , 600mm. " m3 EX - 41 145.O
1.3.34 " " " " , 900mm. " m3 EX - 41 13O.O
1.3.35 " " " " , 1200mm. " m3 EX - 41 1O5.O
1.3.36 300mm wide trench & backfill, 300mm. Deep m3 EX - 41 16O.O
1.3.37 " " " " , 450mm. " m3 EX - 41 14O.O
1.3.38 " " " " , 600mm. " m3 EX - 41 13O.O
1.3.39 " " " " , 900mm. " m3 EX - 41 115.O
1.3.40 400mm wide trench & backfill, 300mm. Deep m3 EX - 41 145.O
1.3.41 " " " " , 450mm. " m3 EX - 41 12O.O
1.3.42 " " " " , 600mm. " m3 EX - 41 115.O

1.4 Pit, Trench & Bulk Excavation (Manual)


pit excavation in ordinary soil
1.4.1 pit not exceeding 1.5m m3 EX - 42 2.7
1.4.2 pit over 1.5m not exceeding 3.0m m3 EX - 42 2.2
1.4.3 pit over 3.0m not exceeding 4.5m m3 EX - 42 1.6
Trench excavation in ordinary soil
1.4.4 Trench not exceeding 1.5m m3 EX - 42 2.7

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
1.4.5 Trench over 1.5m, not exceeding 3.0m m3 EX - 42 2.2
1.4.6 Trench over 3.0m, not exceeding 4.5m m3 EX - 42 1.6
Bulk excavation in ordinary soil
1.4.7 Not exceeding 1.5m. Depth m3 EX - 42 3.0
1.4.8 Over 1.5m. But not exceeding 3.0m m3 EX - 42 2.6
1.4.9 Over 3.0m. But not exceeding 4.5m m3 EX - 42 2.3

Multiplying factors
FOR SOFT SOIL OR SAND
Daily output to be multiplied by 1.O
FOR HEAVY SOIL OR STIFF CLAY
Daily out put multiplied by O.5
FOR WET EXCAVATION
With all other equipment
Daily output to be multiplied by O.6

Pit Excavation in soft rock


1.4.10 Not exceeding 1.5m m3 EX - 43 1.5
1.4.11 Over 1.5m not exceeding 3.0m m3 EX - 43 1.2
1.4.12 Over 3.0m not exceeding 4.5m m3 EX - 43 1.O
Trench Excavation in soft rock
1.4.13 Not exceeding 1.5m m3 EX - 43 1.5
1.4.14 Over 1.5m, not exceeding 3.0m m3 EX - 43 1.2
1.4.15 Over 3.0m, not exceeding 4.5m m3 EX - 43 1.0

Bulk excavation in soft rock


1.4.16 Not exceeding 1.5m depth m3 EX - 43 1.8
1.4.17 Over 1.5m, not exceeding 3.0m m3 EX - 43 1.6
1.4.18 Over 3.0m, not exceeding 4.5m m3 EX - 43 1.3

Pit Excavation in hard rock


1.4.19 Not exceeding 1.5m m3 EX - 43 O.9
1.4.20 Over 1.5m, not exceeding 3.0m m3 EX - 43 O.7
1.4.21 Over 3.0m, not exceeding 4.5m m3 EX - 43 O.4

Trench Excavation in hard rock m3 EX - 43


1.4.22 Not exceeding 1.5m m3 EX - 43 O.7
1.4.23 Over 1.5m, not exceeding 3.0m m3 EX - 43 O.5
1.4.24 Over 3.0m, not exceeding 4.5m O.3
Bulk Excavation in hard rock
1.4.25 Not exceeding 1.5m depth m3 EX - 43 1.O
1.4.26 Over 1.5m, not exceeding 3.0m m3 EX - 43 O.8

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
1.4.27 over 3.0m, not exceeding 4.5m m3 EX - 43 O.5

1.5 Rock Excavation (equipment intensive)

1.5.1 Drilling and Blasting only

1.5.1.1 Rock under 1000m3 m3 EX - 45 135.O


1.5.1.2 Rock over 1000m3 m3 EX - 45 155.O
1.5.1.3 For restricted area rock under 1000m3 m3 EX - 45 24.O
1.5.1.4 For restricted area rock over 1000m3 m3 EX - 45 36.O
1.5.1.5 Trench excavation in rock under 1000m3 m3 EX - 45 41.O
1.5.1.6 Trench excavation in rock over 1000m3 m3 EX - 45 48.O

Pit Exc. In boulder/drilled and blasted rock


1.5.2.7 Not exceeding m3 EX - 44 25O.O
1.5.2.8 Over 1.5m, not exceeding 3.0m m3 EX - 44 175.O
1.5.2.9 Over 3.0m, not exceeding 4.5m m3 EX - 44 115.O

Trench Exc.in boulder/drilled and blasted rock


1.5.2.10 Not exceeding 1.5m m3 EX - 44 25O.O
1.5.2.11 Over 1.5m, not exceeding 3.0m m3 EX - 44 175.O
1.5.2.12 Over 3.0m, not exceeding 4.5m m3 EX - 44 115.O

Bulk, Exc.in boulder/drilled and blasted rock


1.5.2.13 Not exceeding 1.5m depth m3 EX - 44 25O.O
1.5.2.14 Over 1.5m, not exceeding 3.0m m3 EX - 44 185.O
1.5.2.15 Over 3.0m, not exceeding 4.5m m3 EX - 44 14O.O

1.6 Trimming sides and bottom

1.6.1 For concrete pours, regular m2 F-1 56.O


1.6.2 For concrete pours,hard pan m2 F-2 17.O

1.7 Loading

1.7.1 Hand loading trucks from stock pile, sandy soil m3 1 lab 8.1
Hand loading trucks from stock pile, heavy soil or
1.7.2 clay m3 2 lab 5.4
1.7.3 For wet or muck hand loading m3 3 lab O.6
1.8 hauling Earth

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
1.8.1 4.6 m3 dump truck,
1.8.1.1 2.00Km. round trip, 3.3 loads/hr. m3 D-1 12O.O
1.8.1.2 4.00Km. round trip, 2.6 loads/hr. m3 D-1 93.O
1.8.1.3 6.00Km. round trip, 2.1 loads/hr. m3 D-1 74.O
1.8.1.4 8.00Km. round trip, 1.8 loads/hr. m3 D-1 63.O

1.8.2 9.2 m3 dump truck,


1.8.2.1 2.00Km. round trip, 2.7 loads/hr. m3 D-2 195.O
1.8.2.2 4.00Km. round trip, 2.2 loads/hr. m3 D-2 16O.O
1.8.2.3 6.00Km. round trip, 1.9 loads/hr. m3 D-2 135.O
1.8.2.4 8.00Km. round trip, 1.6 loads/hr. m3 D-2 115.O

1.8.3 12.6 m3 dump truck,


1.8.3.1 2.00Km. round trip, 2.6 loads/hr. m3 D -3 26O.O
1.8.3.2 4.00Km. round trip, 2.1 loads/hr. m3 D -3 21O.O
1.8.3.3 6.00Km. round trip, 1.8 loads/hr. m3 D -3 18O.O
1.8.3.4 8.00Km. round trip, 1.6 loads/hr. m3 D -3 16O.O

1.8.4 15.3 m3 dump truck,


1.8.4.1 2.00Km. round trip, 2.5 loads/hr. m3 D -4 3O5.O
1.8.4.2 4.00Km. round trip, 2.0 loads/hr. m3 D -4 245.O
1.8.4.3 6.00Km. round trip, 1.7 loads/hr. m3 D -4 2O5.O
1.8.4.4 8.00Km. round trip, 1.5 loads/hr. m3 D -4 185.O

1.8.5 Multiplying factor

1.8.5.1 Hauling in medium traffic, multiply by O.7


1.8.5.2 Hauling in heavy traffic, multiply by O.6

1.9 Spread, backfill & compact

1.9.1 Bulk fill by hand


1.9.1.1 Bulk fill by hand (no compaction ) Soft soil m3 1 Lab 7.1
1.9.1.2 Bulk fill by hand (no compaction ) Medium soil m3 1Lab 7.1
1.9.1.3 Bulk fill by hand (no compaction ) Heavy soil m3 1 Lab 5.8

1.9.2 Spread & compact


1.9.2.1 Compaction in 150mm layers
1.9.2.1.1 Hand tampers m3 1 Lab 11.5
1.9.2.1.2 Roller compaction m3 F-5 5O.O
1.9.2.1.3 air tamp m3 F-6 91.O
1.9.2.1.4 Vibrating plate m3 F-1 28.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
1.9.2.2 Compaction in 300mm layers
1.9.2.2.1 Hand tampers m3 1 Lab 15.5
1.9.2.2.2 Roller compaction m3 F-5 57.O
1.9.2.2.3 air tamp m3 F-6 1O5.O

1.9.2.2.4 Vibrating plate m3 F-1 33.O

Dozer backfilling up to 100m. Haul with


1.9.2.3 nocompaction. m3 F-2 63O.O
Dozer backfilling up to 100m. Haul with
1.9.2.4 nocompaction. m3 F -7 125.O
Compacted backfill, 150mm - 300mm layers
1.9.2.5 using vibrating rollers m3 F-8 42O.O
Compacted backfill, 150mm - 300mm layers
1.9.2.6 using Sheep foots rollers towed m3 F-9 395.O
Compacted backfill, 150mm - 300mm layers
1.9.2.7 using Sheep foots rollers self propelled m3 F-4 19O.O
Compacted backfill, 150mm - 300mm layers
1.9.2.8 using Sheep foots rollers self propelled m3 F-4 225.O

1.9.3 Gravil fill (compacted)

1.9.3.1 Under floor slab 75mm deep m3 F-3 64O.O


1.9.3.2 Under floor slab 150mm deep m3 F-3 58O.O
1.9.3.3 Under floor slab 250mm deep m3 F-3 46O.O
1.9.3.4 Under floor slab 300mm deep m3 F-3 385.O
1.9.3.5 Alternatively, 75mm deep m3 F-3 48.O
1.9.3.6 " , 150mm deep m3 F-3 85.O
1.9.3.7 " , 250mm deep m3 F-3 1O5.O
1.9.3.8 " , 305mm deep m3 F-3 115.O

1.9.4 Backfill trenches by tamping


1.9.4.1 using air tamp m3 F -6 65.O
1.9.4.2 Using vibrating plate m3 F-1 6O.O

1.1 Grading
Rough grading in ordinary soil upto 100mm cut
1.10.1 With a grader of 150 Hp m2 G-5 215.O
1.10.2 With a grader of 200 Hp m2 G-6 435.O
1.10.3 With a grader of 300 Hp m2 G-7 615.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
Fine grading in ordinary soil up to 50mm cut
1.10.4 With a grader of 150HP m2 G-5 565.O
1.10.5 With a grader of 200HP m2 G-6 84O.O
1.10.6 With a grader of 300HP m2 G-7 119O.O

Spread and grade fill 300mm thick


1.10.7 With a grader of 150HP m2 G-5 85O.O
1.10.8 With a grader of 200HP m2 G-6 161O.O
1.10.9 With a grader of 300HP m2 G-7 235O.O

Spread and grade fill 250mm thick


1.10.10 With a grader of 150HP m2 G-5 1O25.O
1.10.11 With a grader of 200HP m2 G-6 182O.O
1.10.12 With a grader of 300HP m2 G-7 265O.O

Spread and grade fill 200mm thick


1.10.13 With a grader of 150HP m2 G-5 128O.O
1.10.14 With a grader of 200HP m2 G-6 22OO.O
1.10.15 With a grader of 300HP m2 G-7 321O.O

Spread and grade fill 150mm thick


1.10.16 With a grader of 150HP m2 G-5 171O.O
1.10.17 With a grader of 200HP m2 G-6 284O.O
1.10.18 With a grader of 300HP m2 G-7 413O.O

500mm deep tringular ditch with 500mm width


1.10.19 With a grader of 150HP m2 G-5 239O.O
1.10.20 With a grader of 200HP m2 G-6 362O.O
1.10.21 With a grader of 300HP m2 G-7 5O1O.O

500mm deep tringular ditch with 1000mm width


1.10.22 With a grader of 150HP m2 G-5 12OO.O
1.10.23 With a grader of 200HP m2 G-6 181O.O
1.10.24 With a grader of 300HP m2 G-7 251O.O
750mm deep tringular ditch with 500mm width
1.10.25 With a grader of 150HP m2 G-5 8OO.O
1.10.26 With a grader of 200HP m2 G-6 123O.O
1.10.27 With a grader of 300HP m2 G-7 17OO.O

750mm deep tringular ditch with 1000mm width


1.10.28 With a grader of 150HP m2 G-5 4OO.O
1.10.29 With a grader of 200HP m2 G-6 62O.O
1.10.30 With a grader of 300HP m2 G-7 85O.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
1.10.31 Fine grade, 3 passes with motor grader m2 G-3 1OOO.O
1.10.32 With grader plus rolling m2 G-4 1OOO.O
1.10.33 Hand grading, smooth finish m2 1 Lab 47.O
1.10.34 Hand grading, rough finish m2 2 Lab 81.O

1.11 Others

1.11.1 Hardcore 250mm thick m2 HC - 1 14.O


1.11.2 Blinding 30 - 50mm thick m2 HC - 2 48.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

2 FORMWORK

Formes in place, columns (from work made of ply


2.1 wood)
2.1.1 200mm x 200mm
2.1.1.1 1 use m2 FW - 1 10.O
2.1.1.2 2 use m2 FW - 1 12.O
2.1.1.3 3 use m2 FW - 1 13.O
2.1.1.4 multiple use m2 FW - 1 13.5
2.1.2 300mm x 300mm
2.1.2.1 1 use m2 FW - 1 11.5
2.1.2.2 2 use m2 FW - 1 13.5
2.1.2.3 3 use m2 FW - 1 14.O
2.1.2.4 multiple use m2 FW - 1 14.5
2.1.3 400mm x 400mm
2.1.3.1 1 use m2 FW - 1 11.5
2.1.3.2 2 use m2 FW - 1 13.5
2.1.3.3 3 use m2 FW - 1 14.5
2.1.3.4 multiple use m2 FW - 1 15.O
2.1.4 600mm x 600mm
2.1.4.1 1 use m2 FW - 1 12.5
2.1.4.2 2 use m2 FW - 1 14.5
2.1.4.3 3 use m2 FW - 1 15.5
2.1.4.4 multiple use m2 FW - 1 16.O
2.1.5 900mm x 900mm
2.1.5.1 1 use m2 FW - 1 13.5
2.1.5.2 2 use m2 FW - 1 15.5
2.1.5.3 3 use m2 FW - 1 16.5
2.1.5.4 multiple use
2.2 Forms in place, elevated slabs
2.2.1 Flat slab to 4.5m high,
2.2.1.1 1 use m2 FW - 2 17.5
2.2.1.2 2 use m2 FW - 2 19.5
2.2.1.3 3 use m2 FW - 2 2O.5
2.2.1.4 multiple use m2 FW - 2 21.O
2.2.1.5 4.5m to 6.0 high ceilings, multiple use m2 FW - 2 18.5
2.2.1.6 6.0m to 10.0m high ceilings, multiple use m2 FW - 2 17.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
2.2.2 Flat slab with drop panels, to 4.5m high
2.2.2.1 1 use m2 FW - 2 19.5
2.2.2.2 2 use m2 FW - 2 21.5
2.2.2.3 3 use m2 FW - 2 23.O
2.2.2.4 multiple use m2 FW - 2 23.5
2.2.2.5 4.5m to 6.0 high ceilings, multiple use m2 FW - 2 2O.5
2.2.2.6 6.0m to 10.0m high ceilings, multiple use m2 FW - 2 18.5

2.2.3 Floor slab hanging from steel beams


2.2.3.1 1 use m2 FW - 2 3O.O
2.2.3.2 2 use m2 FW - 2 33.O
2.2.3.3 3 use m2 FW - 2 34.O
2.2.3.4 multiple use m2 FW - 2 35.O

2.2.4 Box out for slab opening, over 400mm deep


2.2.4.1 1 use m2 FW - 2 1O.O
2.2.4.2 2 use m2 FW - 2 12.5
2.2.4.3 Shallow slab bos out to 1.00m2 m2 FW - 2 28.O
2.2.4.4 Over 1.00m2 (use perimeter) m2 FW - 2 81.O
Curb forms, wood 150mm to 300m high, on
2.2.5 elevatred slabs
2.2.5.1 1 use m2 FW - 1 7.2
2.2.5.2 2 use m2 FW - 1 8.2
2.2.5.3 3 use m2 FW - 1 8.8
2.2.5.4 multiple use m2 FW - 1 66.O
Edge forms to 150mm to 300mm high , multiple
2.2.5.5 use m2 FW - 1 12.O

2.3 Forms in-place, equipment foundations


2.3.1 1 use m2 FW - 2 11.O
2.3.2 2 use m2 FW - 2 13.5
2.3.3 3 use m2 FW - 2 14.O
2.3.4 multiple use m2 FW - 2 14.5

2.4 Forms in - place, footing & continuous wall


2.4.1 1 use m2 FW - 1 12.O
2.4.2 2 use m2 FW - 1 14.O
2.4.3 3 use m2 FW - 1 15.O
2.4.4 multiple use m2 FW - 1 15.5

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

2.5 Forms in - place, spread footings


2.5.1 1 use m2 FW - 1 1O.5
2.5.2 2 use m2 FW - 1 12.5
2.5.3 3 use m2 FW - 1 13.5
2.5.4 multiple use m2 FW - 1 14.5

2.6 Forms in place, grade beam


2.6.1 1 use m2 FW - 2 17.O
2.6.2 2 use m2 FW - 2 18.5
2.6.3 3 use m2 FW - 2 19.O
2.6.4 multiple use m2 FW - 2 19.O

2.7 Forms in place, mat foundation


2.7.1 1 use m2 FW - 2 12.5
2.7.2 2 use m2 FW - 2 15.O
2.7.3 3 use m2 FW - 2 15.5

Forms in place, beams & girders


2.8.1 Beam and girder, ext. spandrel, 300mm, wide
2.8.1.1 1 use m2 FW - 2 12.5
2.8.1.2 2 use m2 FW - 2 15.O
2.8.1.3 3 use m2 FW - 2 16.O
2.8.1.4 multiple use m2 FW - 2 17.O

2.8.2 Exterior spandrel, 500mm wide


2.8.2.1 1 use m2 FW - 2 14.5
2.8.2.2 2 use m2 FW - 2 16.O
2.8.2.3 3 use m2 FW - 2 17.5
2.8.2.4 multiple use m2 FW - 2 18.O

2.8.3 Exterior spandrel, 600mm wide


2.8.3.1 1 use m2 FW - 2 15.O
2.8.3.2 2 use m2 FW - 2 16.O
2.8.3.3 3 use m2 FW - 2 17.5
2.8.3.4 multiple use m2 FW - 2 18.O

2.8.4 Interior beams, 300mm wide


2.8.4.1 1 use m2 FW - 2 14.O
2.8.4.2 2 use m2 FW - 2 17.O
2.8.4.3 3 use m2 FW - 2 18.O
2.8.4.4 multiple use m2 FW - 2 19.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
2.8.5 Interior beams, 600mm wide
2.8.5.1 1 use m2 FW - 2 16.5
2.8.5.2 2 use m2 FW - 2 18.5
2.8.5.3 3 use m2 FW - 2 19.5
2.8.5.4 multiple use m2 FW - 2 2O.O

2.8.6 Beam and girder, encasing steel frame hung


2.8.6.1 1 use m2 FW - 2 17.O
2.8.6.2 2 use m2 FW - 2 2O.5
2.8.6.3 3 use m2 FW - 2 21.5
2.8.6.4 multiple use m2 FW - 2 22.5

2.8.7 Beam bottoms only, 600mm wide


2.8.7.1 1 use m2 FW - 2 13.O
2.8.7.2 2 use m2 FW - 2 15.O
2.8.7.3 3 use m2 FW - 2 16.O
2.8.7.4 multiple use m2 FW - 2 16.5

2.8.8 Beam sides only, vertical, 1000mm high


2.8.8.1 1 use m2 FW - 2 15.O
2.8.8.2 2 use m2 FW - 2 18.5
2.8.8.3 3 use m2 FW - 2 19.5
2.8.8.4 multiple use m2 FW - 2 2O.O

2.8.9 Beam sides only, sloped, 1000mm high,


2.8.9.1 1 use m2 FW - 2 14.5
2.8.9.2 2 use m2 FW - 2 18.O
2.8.9.3 3 use m2 FW - 2 19.5
2.8.9.4 multiple use m2 FW - 2 2O.5

2.8.10 Upstanding beams 1000mm high


2.8.10.1 1 use m2 FW - 2 12.5
2.8.10.2 2 use m2 FW - 2 14.O
2.8.10.3 3 use m2 FW - 2 15.O
2.8.10.4 multiple use m2 FW - 2 15.5

2.9 Forms in place, walls


2.9.1 up to 2.50m high
2.9.1.1 1 use m2 FW - 2 14.O
2.9.1.2 2 use m2 FW - 2 16.5
2.9.1.3 3 use m2 FW - 2 19.O
2.9.1.4 multiple use m2 FW - 2 19.5

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
2.9.2 Over 2.50 to 5.00m high
2.9.2.1 1 use m2 FW - 2 12.O
2.9.2.2 2 use m2 FW - 2 15.O
2.9.2.3 3 use m2 FW - 2 17.O
2.9.2.4 multiple use m2 FW - 2 16.O

2.9.3 Over 5.00m high


2.9.3.1 1 use m2 FW - 2 1O.5
2.9.3.2 2 use m2 FW - 2 12.5
2.9.3.3 3 use m2 FW - 2 13.5
2.9.3.4 multiple use m2 FW - 2 14.5

2.9.4 Box out for wall openings, upto 400mm thick yo 1.00m2 No FW - 2 18.O

2.9.5 Box out for wall openings,over, 1.00m2 (use perimeter) m FW - 2 49.5
Form works in soft wood, sub-structure in normal finish
2.1O to:
2.10.1 Footing m2 FW - 3 4.4
2.10.2 Subgrade column m2 FW - 3 4.7
2.10.3 Grade beam m2 FW - 3 4.6
2.10.4 Suspended slab m2 FW - 3 4.7
2.10.5 Concrete wall m2 FW - 3 4.3
2.10.6 Lift shaft m2 FW - 3 4.3
2.10.7 Mat foundation m2 FW - 3 4.4

Formwork in soft wood, super structure in normal finish


2.11 to:
2.11.1 Elevation columns m2 FW - 3 4.7
2.11.2 Beams and lintels m2 FW - 3 4.5
2.11.3 Slab m2 FW - 3 4.7
2.11.4 Concrete walls m2 FW - 3 4.3
2.11.5 Lift shaft m2 FW - 3 4.3
2.11.6 Stair case and landing m2 FW - 3 4.3
2.11.7 Parapet m2 FW - 3 4.3
2.11.8 Canopy m2 FW - 3 4.7
2.11.9 Transom and mullions m2 FW - 3 2.3
2.12 Fair-faced concrete formwork in soft wood to:
2.12.1 Elevation columns m2 FW - 4 6.5
2.12.2 Beams and lintels m2 FW - 4 6.9
2.12.3 Slabs m2 FW - 4 6.7
2.12.4 Concrete walls m2 FW - 4 6.7
2.12.5 Lift shaft m2 FW - 4 6.7

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
2.12.6 Stair case and landing m2 FW - 4 6.7
2.12.7 Parapet m2 FW - 4 6.7
2.12.8 Canopy m2 FW - 4 6.7
2.12.9 Transom and mullions m2 FW - 4 6.2

2.13 Patterned concrete form work to m2 FW - 5 3.4


2.13.1 Elevation columns m2 FW - 5 3.4
2.13.2 Slab m2 FW - 5 3.4
2.13.3 Concrete wall m2 FW - 5 3.4
2.13.4 Lift shalf m2 FW - 5 3.4

Formwork in soft wood for columns up to 3.0m


2.14 high m2 FW - 6 4.3
2.15 Formwork in soft wood for ground beams m2 FW - 6 4.7
2.16 Formwork in soft wood for slabs m2 FW - 6 4.9
2.17 Formwork in steel panels for slabs m2 FW - 6 8.O

1.18 Forms in plce, culvert


2.18.1 1500mm to 2500mm, square or rectangular
2.18.1.1 1 use m2 FW - 1 9.4
2.18.1.2 2 use m2 FW - 1 9.4
2.18.1.3 3 use m2 FW - 1 9.4
2.18.1.4 multiple use m2 FW - 1 9.4

2.19 Scaffoldings tubular steel


2.19.1 Building exterior (walls)
2.19.1.1 1 to 5 stories m2 3 carps 64.O
2.19.1.2 6 to 12 stories m2 4 carps 57.O
2.19.1.3 13 to 20 stories m2 5 carps 64.O

2.19.2 Building interior (walls)


2.19.2.1 1 to 5m m2 3 carps 93.O
2.19.2.2 5 to 12m m2 3 carps 77.O

2.19.3 Building interior


2.19.3.1 up to 9m high m2 3 carps 91.O
2.19.3.2 over 9m high m2 4 carps 1O5.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

3 Reinforcement

Cutting, bending, tying and placing of steel


3.1 reinforcement
3.1.1 Beam & girders, 6mm to 14mm kg SR - 1 25O
3.1.2 Beam & girders, 16mm to 28mm kg SR - 1 425.0
3.1.3 Column 6mm to 14mm kg SR - 1 235.0
3.1.4 Column 16mm to 28mm kg SR - 1 36O

Cutting, bending, tying and placing of


3.2 substructure steel reinforcement
3.2.1 diameter 6mm kg SR - 2 225.0
3.2.2 diameter 8mm - 10mm kg SR - 2 26O
3.2.3 diameter 12mm - 18mm kg SR - 2 31O
3.2.4 diameter 20mm - 26mm kg SR - 2 33O
3.2.5 diameter 28mm -32mm kg SR - 2 355.0

Cutting, bending, tying and placing of super-


3.3 structure steel reinforcement
3.3.1 diameter 6mm kg SR - 2 185.0
3.3.2 diameter 8mm - 10mm kg SR - 2 21O
3.3.3 diameter 12mm - 18mm kg SR - 2 275.0
3.3.4 diameter 20mm - 26mm kg SR - 2 295.0
3.3.5 diameter 28mm -32mm kg SR - 2 3O5

cutting, bending, tying and placing of steel


3.4 reinforcement kg SR - 3 12O
3..4.1 All diameters kg SR - 3 12O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

4 Concrete

4.1 Concrete placing & vibrating

4.1.1 small elevated beams, < 0.09m2


4.1.1.1. Pumped m3 C - F1 24.5
4.1.1.2. With crane & bucket m3 C - F2 27.O

4.1.2 Large elevated beams >.25m2


4.1.2.1 Pumped m3 C - F1 36.5
4.1.2.2 With crane & bucket m3 C - F2 39.5

4.1.3 Columns, square or round


4.1.3.1 Pumped, of thickness
4.1.3.1.1 up to 300mm m3 C - F1 28.O
4.1.3.1.2 300 to 450mm m3 C - F1 37.5
4.1.3.1.3 450 to 500mm m3 C - F1 57.O
4.1.3.1.4 800 to 900mm m3 C - F1 87.O
4.1.3.2 With crane & bucket, of thickness
4.1.3.2.1 up to 300mm m3 C - F2 25.5
4.1.3.2.2 300 to 400mm m3 C - F2 35.O
4.1.3.2.3 450 to 610mm m3 C - F2 44.O
4.1.3.2.4 800 to 900mm m3 C - F2 63.O

4.1.4 Elevated slabs, less than 150mm thick


4.1.4.1 Pumped m3 C - F1 65.O
4.1.4.2 With crane and bucket. m3 C - F2 57.O
4.1.5 Elevated slabs
4.1.5.1 150mm to 255mm thick, pumped m3 C - F1 78.O
4.1.5.2 150mm to 255mm thick with crane and bucket m3 C - F2 65.O

4.1.6 Slabs over 255mm thick


4.1.6.1 Pumped m3 C - F1 91.O
4.1.6.2 With crane and bucket. m3 C - F2 79.O

4.1.7 Shallow < 3m continuos footing


4.1.7.1 Direct chute m3 C - F3 79.O
4.1.7.2 pumped m3 C - F1 66.O
4.1.7.3 with crane & bucket m3 C - F2 6O.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
4.1.8 Deep >3m continous footings
4.1.8.1 Direct chute m3 C - F3 96.O
4.1.8.2 pumped m3 C - F1 75.O
4.1.8.3 With crane & bucket m3 C - F2 68.O
4.1.9 Spread footings, under 1.00m3
4.1.9.1 Direct chute m3 C - F3 35.O
4.1.9.2 pumped m3 C - F1 32.O
4.1.9.3 With crane & bucket m3 C - F2 28.5

4.1.10 Spread footings, over 4.00m3


4.1.10.1 Direct chute m3 C - F3 5O.O
4.1.10.2 pumped m3 C - F1 48.O
4.1.10.3 With crane & bucket m3 C - F2 46.O

4.1.11 Mat foundation, over 15.00m3


4.1.11.1 Direct chute m3 C - F3 23O.O
4.1.11.2 pumped m3 C - F1 21O.O
4.1.11.3 With crane & bucket m3 C - F2 195.O
4.1.12 Grade beam, < .09m3
4.1.12.1 Direct chute m3 C - F3 95.O
4.1.12.2 pumped m3 C - F1 85.O
4.1.12.3 With crane & bucket m3 C - F2 8O.O

4.1.13 Grade beam, > .25m2


4.1.13.1 Direct chute m3 C - F3 86.O
4.1.13.2 pumped m3 C - F1 75.O
4.1.13.3 With crane & bucket m3 C - F2 69.O

4.1.14 Pile caps, under 4.00m2


4.1.14.1 Direct chute m3 C - F3 55.O
4.1.14.2 pumped m3 C - F1 52.O
4.1.14.3 With crane & bucket m3 C - F2 49.O

4.1.15 Pile caps, over 8.00m3


4.1.15.1 Direct chute m3 C - F3 135.O
4.1.15.2 pumped m3 C - F1 125.O
4.1.15.3 With crane & bucket m3 C - F2 12O.O

4.1.16 Slab on grade, 100mm thick,


4.1.16.1 Direct chute m3 C - F3 67.O
4.1.16.2 pumped m3 C - F1 74.O
4.1.16.3 With crane & bucket m3 C - F2 67.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
4.1.17 Slab on grade over 150mm thick
4.1.17.1 Direct chute m3 C - F3 1OO.O
4.1.17.2 pumped m3 C - F1 1OO.O
4.1.17.3 With crane & bucket

4.1.18 Walls, 200mm thick,


4.1.18.1 Direct chute m3 C - F3 61.O
4.1.18.2 pumped m3 C - F1 57.O
4.1.18.3 With crane & bucket m3 C - F2 54.O

4.1.19 Walls, 300mm thick,


4.1.19.1 Direct chute m3 C - F3 62.O
4.1.19.2 pumped m3 C - F1 59.O
4.1.19.3 With crane & bucket m3 C - F2 56.O

Wheeled concrete dumping, as extra activity to


4.1.20 the placing mentioned above
4.1.20.1 wheel barrow
4.1.20.1.1 15.00m haul m3 C - F5 15.5
4.1.20.1.2 50.00m haul m3 C - F5 11.O
4.1.20.1.3 75.00m haul m3 C - F5 8.5

4.1.20.2 Concrete dumper


4.1.20.2.1 15.00m haul m3 C - F6 58.O
4.1.20.2.2 50.00m haul m3 C - F6 38.O
4.1.20.2.3 75.00m haul m3 C - F6 44.O

Concrete in place including steel forms and


4.2 reinforcing steel

4.2.1 General Output, including trowel finishing


4.2.1.1 Average for framed building m3 C - F7 1O.O
4.2.1.2 Average for substructure only m3 C - F7 2O.O
4.2.1.3 Average for superstructure only, including m3 C - F7 9.2

4.2.2 Columns
4.2.2.1 300mm x 300mm, minimum reinforcing m3 C - F4 2.6
4.2.2.2 300mm x 300mm, averagereinforcing m3 C - F4 2.3
4.2.2.3 300mm x 300mm, maximum reinforcing m3 C - F7 2.O
4.2.2.4 400mm x 400mm, minimum reinforcing m3 C - F4 3.5
4.2.2.5 400mm x 400mm, average reinforcing m3 C - F4 2.9
4.2.2.6 400mm x 400mm, maximum reinforcing m3 C - F7 2.4

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
4.2.2.7 600mm x 600mm, minimum reinforcing m3 C - F4 4.8
4.2.2.8 600mm x 600mm, averagereinforcing m3 C - F4 4.O
4.2.2.9 600mm x 600mm, maximum reinforcing m3 C - F4 3.2
4.2.2.10 900mm x 900mm, minimum reinforcing m3 C - F7 7.5
4.2.2.11 900mm x 900mm, average reinforcing m3 C - F7 6.8
4.2.2.12 900mm x 900mm, maximum reinforcing m3 C - F7 4.2

4.2.3 Columns, round, spirals, 400mm diam.


4.2.3.1 minimum reinforcing m3 C - F7 6.8
4.2.3.2 average reinforcing m3 C - F7 4.3
4.2.3.3 maximum reinforcing m3 C - F7 3.1

4.2.4 Columns, round, spirals, 500mm diam.


4.2.4.1 minimum reinforcing m3 C - F7 7.9
4.2.4.2 average reinforcing m3 C - F7 4.5
4.2.4.3 maximum reinforcing m3 C - F7 3.3
4.2.5 Columns, round, spirals, 600mm diam.
4.2.5.1 minimum reinforcing m3 C - F7 9.4
4.2.5.2 average reinforcing m3 C - F7 6.1
4.2.5.3 maximum reinforcing m3 C - F7 4.O

4.2.6 Columns, round, spirals, 900mm diam.


4.2.6.1 minimum reinforcing m3 C - F7 15.5
4.2.6.2 average reinforcing m3 C - F7 1O.O
4.2.6.3 maximum reinforcing m3 C - F7 6.O

Curbs, 150mm x 500mm, straight, formed in


4.2.7 place m3 C - F8 97.O
m3 C - F8 42.5
4.2.8 concrete gutter 100mm thick

4.2.9 Elevated flat slabs


4.2.9.1 6.00 span m3 C - F4 1O.5
4.2.9.2 9.00 span m3 C - F7 12.5

4.2.10 one way slab and beam


4.2.10.1 4.00m span m3 C - F4 6.6
4.2.10.2 8.00m span m3 C - F4 6.4

4.2.11 Two way slab and beam


4.2.11.1 4.00m span m3 C - F4 5.5
4.2.11.2 8.00m span m3 C - F7 8.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
4.2.12 Footings, spread
4.2.12.1 under 1.00m3 m3 C - F7 11.5
4.2.12.2 Over 4.00m4 m3 C - F10 3O.O
4.2.13 footing, strip
4.2.13.1 500mm x 200mm plain m3 C - F7 14.O
4.2.13.2 1000mm x 300mm m3 C - F7 22.O

4.2.14 Foundation, mat


4.2.14.1 <10.00m3 m3 C - F7 11.5
4.2.14.2 >15.00m3 m3 C - F7 15.O

4.2.15 Grade wall


4.2.15.1 200mm thick, 2.50m high m3 C - F4 5.8
4.2.15.2 200mm thick, 4.50m high m3 C - F4 4.5
4.2.15.3 300mm thick, 2.50m high m3 C - F4 8.2
4.2.15.4 300mm thick, 4.50m high m3 C - F4 7.1
4.2.15.5 400mm thick, 2.50m high m3 C - F4 11.O
4.2.15.6 400mm thick, 3.50m high m3 C - F4 9.O
4.2.15.7 400mm thick, 5.50m high m3 C - F4 7.3

4.2.16 Ground slab, not including finish


4.2.16.1 100mm thick m3 C - F10 43.O
4.2.16.2 150mm thick m3 C - F10 52.O

4.2.17 Ground slab, including trawled finish


4.2.17.1 100mm thick slab, over 1000m2 m2 C - F9 13O.O
4.2.17.2 150mm thick slab, over 1000m2 m2 C - F9 125.O
4.2.17.3 200mm thick slab, over 1000m2 m2 C - F9 115.O

4.2.17.4 300mm thick slab, over 1000m2 m2 C - F9 87.O


4.2.17.5 400mm thick slab, over 1000m3 m2 C - F9 8O.O

4.2.18 Elevated slab, including trowelled finish,


4.2.18.1 100mm slab m2 C - F9 125.O
4.2.18.2 150mm slab m2 C - F9 11O.O

In situ concrete, excluding forms and reinforcing


4.3 steel

4.3.1 Plain blinding concrete m3 C - F11 12.O

4.3.2 Reinforced sub-structure concrete in:


4.3.1 Footing m3 C - F11 12.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
4.3.2.2 Sub grade columns m3 C - F11 8.5
4.3.2.3 Sub gadbeam m3 C - F11 10.5
4.3.2.4 Grade beam m3 C - F11 10.5
4.3.2.5 Ground slab m3 C - F11 12.O
4.3.2.6 Suspended slab m3 C - F11 9.O
4.3.2.7 Concrete wall m3 C - F11 7.5
4.3.2.8 Lift shaft m3 C - F11 7.5
4.3.2.9 Stair case landing m3 C - F11 11.O
4.3.2.10 Mat foundation m3 C - F11 12.O
4.3.3 Reingorced square-structure Concrete in:
4.3.3.1 Elevation columns m3 C - F11 5.O
4.3.3.2 Beams and lintels m3 C - F11 8.5
4.3.3.3 Suspended slab m3 C - F11 1O.O
4.3.3.4 Ribbed slab m3 C - F11 11.5
4.3.3.5 Concrete wall m3 C - F11 8.O
4.3.3.6 Lift shaft m3 C - F11 8.O
4.3.3.7 Stair case landing m3 C - F11 1O.5
4.3.3.8 Parapet m3 C - F11 8.O
4.3.3.9 Canopy m3 C - F11 8.O
4.3.3.10 Transoms and mullions m3 C - F11 7.O

4.3.4 Reinforced concrete of all types in:


4.3.4.1 Footing and slabs m3 C - F12 19.O
4.3.4.2 Footing and slabs m3 C - F13 3O.5
4.3.4.3 Footing and slabs m3 C - F14 32.5
4.3.4.4 Beams m3 C - F12 13.O
4.3.4.5 Beams m3 C - F13 17.O
4.3.4.6 Beams m3 C - F14 22.O
4.3.4.7 Columns m3 C - F12 6.5
4.3.4.8 Columns m3 C - F13 7.5
4.3.4.9 Columns m3 C - F14 9.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

5 Masonry & brickwork

5.1 Mortar & masonary accessories

5.1.1 Mortar
5.1.1.1 With mortar mixer m3 BW - 3 4.O
5.1.1.2 With hand tools m3 2 Lab 2.7

5.1.2 Joint Reinforcing


5.1.2.1 Steel bars placed horizontal
5.1.2.1.1 8mm to 10mm kg 1 Mason 115.O
5.1.2.1.2 12mm to 14mm kg 1 Mason 185.O

5.1.2.2 Sttel bars placed vertical


5.1.2.2.1 8mm to 10mm kg 1 Mason 78.O
5.1.2.2.2 12mm to 14mm kg 1Mason 125.O

5.1.2.3 Wire strips for brick work


5.1.2.3.1 For 120mm wall m 1 Mason 315.O
5.1.2.3.2 For 120mm wall m 1Mason 19O.O

5.1.2.4 Wire strips for brick work


5.1.2.4.1 For 100mm wall m 1 Mason 335.O
5.1.2.4.2 For 150mm wall m 1Mason 28O.O
5.1.2.4.3 For 200mm wall m 1Mason 175.O

5.2 Brick work (240mm x 60mm x120mm)

5.2.1 General in cement mortar in:


5.2.1.1 120mm wall as face brick m2 BW - 2 16.O
5.2.1.2 120mm wall as back-up m2 BW - 2 18.O
5.2.1.3 240mm thick wall m2 BW - 2 1O.O
5.2.1.4 360mm thick wall m2 BW - 2 7.O
5.2.1.5 480mm thick wall m2 BW - 2 5.6

5.2.2 Foundation brick work


5.2.2.1 60mm thick trowel cut joints m2 BW - 1 7.2
5.2.2.2 60mm thick tooled joint one side m2 BW - 1 7.2
5.2.2.3 120mm thick trowel cut joints m2 BW - 1 4.8
5.2.2.4 120mm thick tooled joint one side m2 BW - 1 4.7
5.2.2.5 240mm thick trowel cut joints m2 BW - 1 3.1
5.2.2.6 240mm thick tooled joint one side m2 BW - 1 3.1

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

5.2.3 Parition brick work


5.2.3.1 60mm thick trowel cut joints m2 BW - 1 7.3
5.2.3.2 60mm thick tooled joint one side m2 BW - 1 7.3
5.2.3.3 60mm thick tooled joint both side m2 BW - 1 7.3
5.2.3.4 120mm thick trowel cut joints m2 BW - 1 5.O
5.2.3.5 120mm thicktooled joint one side m2 BW - 1 5.O
5.2.3.6 120mm thick tooled joint both side m2 BW - 1 5.O
5.2.3.7 240mm thick trowel cut joints m2 BW - 1 3.5
5.2.3.8 240mm thick tooled joint one side m2 BW - 1 3.5
5.2.3.9 240mm thick tooled joint both side m2 BW - 1 3.5

5.3 Concrete block masonry

5.3.1 Concrete block as back-up


5.3.1.1 in solid regular blocks
5.3.1.1.1 50mm thick m2 BW -2 26.O
5.3.1.1.2 100mm thick m2 BW - 2 24.O
5.3.1.1.3 150mm thick m2 BW - 2 23.O
5.3.1.1.4 200mm thick m2 BW - 2 22.O
5.3.1.2 in Hollow regular blocks
5.3.1.2.1 100mm thick m2 BW - 2 23.5
5.3.1.2.2 150mm thick m2 BW - 2 22.5
5.3.1.2.3 200mm thick m2 BW - 2 21.O
5.3.1.2.4 250mm thick m2 BW - 2 2O.5
5.3.1.2.5 300mm thick m2 BW - 2 2O.O

5.3.2 Foundation walls


5.3.2.1 in hallow regular blocks
5.3.2.1.1 100mm thick, trowel cut joints m2 BW - 2 23.O
5.3.2.1.2 100mm thick, tooled joint, 1 side m2 BW - 2 23.O
5.3.2.1.3 150mm thick, trowel cut joints m2 BW - 2 22.5
5.3.2.1.4 150mm thick, tooled joint, 1 side m2 BW - 2 22.5
5.3.2.1.5 200mm thick, trowel cut joints m2 BW - 2 22.5
5.3.2.1.6 200mm thick, tooled joint, 1 side m2 BW - 2 22.O
5.3.2.1.7 250mm thick, trowel cut joints m2 BW - 2 21.O
5.3.2.1.8 250mm thick, tooled joint, 1 side m2 BW - 2 21.O
5.3.2.1.9 300mm thick, trowel cut joints m2 BW - 2 2O.O
5.3.2.1.10 300mm thick, tooled joint, 1 side m2 BW - 2 2O.O
5.3.2.2 in solid regular blocks
5.3.2.2.1 100mm thick, trowel cut joints m2 BW - 2 24.O
5.3.2.2.2 100mm thick, tooled joint, 1 side m2 BW - 2 24.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
5.3.2.2.3 150mm thick, trowel cut joints m2 BW - 2 23.O
5.3.2.2.4 150mm thick, tooled joint, 1 side m2 BW - 2 23.O
5.3.2.2.5 200mm thick, trowel cut joints m2 BW - 2 22.O
5.3.2.2.6 200mm thick, tooled joint, 1 side m2 BW - 2 22.O
5.3.2.2.7 250mm thick, trowel cut joints m2 BW - 2 21.O
5.3.2.2.8 250mm thick, tooled joint, 1 side m2 BW - 2 21.O
5.3.2.2.9 300mm thick, trowel cut joints m2 BW - 2 2O.O
5.3.2.2.10 300mm thick, tooled joint, 1 side m2 BW - 2 2O.O
5.3.3 Partion walls
5.3.3.1 In hollow regular blocks
5.3.3.1.1 100mm thick, trowel cut m2 BW - 2 23.5
5.3.3.1.2 100mm thick, tooled joint, 1 side m2 BW - 2 23.5
5.3.3.1.3 100mm thick, tooled joint, both sides m2 BW - 2 23.5
5.3.3.1.4 150mm thick, trowel cut m2 BW - 2 22.O
5.3.3.1.5 150mm thick, tooled joint, 1 side m2 BW - 2 22.O
5.3.3.1.6 150mm thick, tooled joint, both sides m2 BW - 2 22.O
5.3.3.1.7 200mm thick, trowel cut m2 BW - 2 2O.5
5.3.3.1.8 200mm thick, tooled joint, 1 side m2 BW - 2 2O.5
5.3.3.1.9 200mm thick, tooled joint, both sides m2 BW - 2 2O.5
5.3.3.1.10 250mm thick, trowel cut m2 BW - 2 19.5
5.3.3.1.11 250mm thick, tooled joint, 1 side m2 BW - 2 19.5
5.3.3.1.12 250mm thick, tooled joint, both sides m2 BW - 2 19.5
5.3.3.1.13 300mm thick, trowel cut m2 BW - 2 18.5
5.3.3.1.14 300mm thick, tooled joint, 1 side m2 BW - 2 18.5
5.3.3.1.15 300mm thick, tooled joint, both sides m2 BW - 2 18.5

5.3.3.2 In soild regular blocks


5.3.3.2.1 50mm thick m2 BW - 2 25.5
5.3.3.2.2 75mm thick m2 BW - 2 25.O
5.3.3.2.3 100mm thick, trowel cut m2 BW - 2 24.O
5.3.3.2.4 100mm thick, tooled joint, 1 side m2 BW - 2 24.O
5.3.3.2.5 100mm thick, tooled joint, both sides m2 BW - 2 24.O
5.3.3.2.6 150mm thick, trowel cut m2 BW - 2 22.5
5.3.3.2.7 150mm thick, tooled joint, 1 side m2 BW - 2 22.5
5.3.3.2.8 150mm thick, tooled joint, both sides m2 BW - 2 22.5
5.3.3.2.9 200mm thick, trowel cut m2 BW - 2 21.O
5.3.3.2.10 200mm thick, tooled joint, 1 side m2 BW - 2 21.O
5.3.3.2.11 200mm thick, tooled joint, both sides m2 BW - 2 21.O
5.3.3.2.12 300mm thick, trowel cut m2 BW - 2 19.O
5.3.3.2.13 300mm thick, tooled joint, 1 side m2 BW - 2 19.O
5.3.3.2.14 300mm thick, tooled joint, both sides m2 BW - 2 19.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
5.3.3.3 In lightweight regular blocks
5.3.3.3.1 50mm thick, trowel cut m2 BW - 2 25.5
5.3.3.3.2 50mm thick, tooled joint, 1 side m2 BW - 2 25.5
5.3.3.3.3 50mm thick, tooled joint, both sides m2 BW - 2 25.5
5.3.3.3.4 100mm thick, trowel cut m2 BW - 2 25.O
5.3.3.3.5 100mm thick, tooled joint, 1 side m2 BW - 2 25.O
5.3.3.3.6 100mm thick, tooled joint, both sides m2 BW - 2 25.O
5.3.3.3.7 150mm thick, trowel cut m2 BW - 2 23.O
5.3.3.3.8 150mm thick, tooled joint, 1 side m2 BW - 2 23.O
5.3.3.3.9 150mm thick, tooled joint, both sides m2 BW - 2 23.O
5.3.3.3.10 200mm thick, trowel cut m2 BW - 2 21.5
5.3.3.3.11 200mm thick, tooled joint, 1 side m2 BW - 2 21.5
5.3.3.3.12 200mm thick, tooled joint, both sides m2 BW - 2 21.5
5.3.3.3.13 250mm thick, trowel cut m2 BW - 2 21.O
5.3.3.3.14 250mm thick, tooled joint, 1 side m2 BW - 2 21.O
5.3.3.3.15 250mm thick, tooled joint, both sides m2 BW - 2 21.O
5.3.3.3.16 300mm thick, trowel cut m2 BW - 2 19.5
5.3.3.3.17 300mm thick, tooled joint, 1 side m2 BW - 2 19.5
5.3.3.3.18 300mm thick, tooled joint, both sides m2 BW - 2 19.5

5.3.3.4 in lightweight bl. 200mm x 600mm


5.3.3.4.1 100mm thick, trowel cut m2 BW - 2 24.O
5.3.3.4.2 100mm thick, tooled joint, 1 side m2 BW - 2 24.O
5.3.3.4.3 100mm thick, tooled joint, both sides m2 BW - 2 24.O
5.3.3.4.4 150mm thick, trowel cut m2 BW - 2 23.O
5.3.3.4.5 150mm thick, tooled joint, 1 side m2 BW - 2 23.O
5.3.3.4.6 150mm thick, tooled joint, both sides m2 BW - 2 23.O
5.3.3.4.7 200mm thick, trowel cut m2 BW - 2 21.5
5.3.3.4.8 200mm thick, tooled joint, 1 side m2 BW - 2 21.5
5.3.3.4.9 200mm thick, tooled joint, both sides m2 BW - 2 21.5
5.3.3.4.10 250mm thick, trowel cut m2 BW - 2 2O.O
5.3.3.4.11 250mm thick, tooled joint, 1 side m2 BW - 2 2O.O
5.3.3.4.12 250mm thick, tooled joint, both sides m2 BW - 2 2O.O
5.3.3.4.13 300mm thick, trowel cut m2 BW - 2 19.O
5.3.3.4.14 300mm thick, tooled joint, 1 side m2 BW - 2 19.O
5.3.3.4.15 300mm thick, tooled joint, both sides m2 BW - 2 19.O

5.4

5.4.1 General
including excavation, concrete footing and stone
1000mm below grade

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
Decorative random stone, to 2000mm high,
5.4.1.1 500mm thick

5.4.1.1.1 dry set m2 BW - 1 2.1


5.4.1.1.2 mortar set m2 BW - 1 2.4
5.4.1.2 cut stone, to 2000mm, 500mm thick,
5.4.2.1 dry set m2 BW - 1 2.1
5.4.2.2 mortar set m2 BW - 1 2.4
Random stone, retainintg wall, 2000mm to
5.4.1.3 3000mm high, 600mm thick
5.4.1.3.1 dry set m2 BW - 1 2.4
5.4.1.3.2 mortar set m2 BW - 1 2.6
cut stone, to 2000mm to 3000mm high, 600mm
5.4.1.4 thick,
5.4.1.4.1 dry set m2 BW - 1 2.4
5.4.1.8 mortar set m2 BW - 1 2.6
5.4.1.5 rough stone wall in mortar
5.4.1.5.1 under 500mm thick m2 BW - 1 1.2
5.4.1.5.2 Over 500mm thick m2 BW - 1 2.2

5.4.2 Stone walls


5.4.2.1 Rubble stone foundation below ground level m2 SM - 1 2.3
Stone masonry above ground level up to 1.5m
5.4.2.2 height m2 SM - 2 1.9
Stone masonry above ground level above 1.5m
5.4.2.3 height m2 SM - 3 1.5

5.4.3 Roughly dressed stone wall facing


5.4.3.1 Both sides roughly dressed m2 SM - 3 1.3
5.4.3.2 One side roughly dressed m2 SM - 1 1.2

5.4.4 Dressed stone wall facing


5.4.4.1 Both sides dressed m2 SM - 3 1.4
5.4.4.2 One side dressed m2 SM - 1 1.2

5.5 Window sill

5.5.1 Cut stone 125mm x 200mm plain m BW - 1 18.5


5.5.2 Face brick on edge m BW - 1 17.5
5.5.3 Marble, 300mm wide, 25mm thick m BW - 1 18.5
5.5.4 Precast concrete sections 50mm
5.5.4.1 150mm wide m BW - 1 17.O
5.5.4.2 250mm wide m BW - 1 17.O
5.5.4.3 350mm wide m BW - 1 17.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

5.6 Brick paving (normal)


5.6.1 240mm x 120mm facing upwards m2 BW - 1 7.6
5.6.2 Grouted 10mm joint m2 BW - 1 6.3
5.6.3 240mm x 60mm facing upwards m2 BW - 1 3.8
5.6.4 Grouted 10mm joint m2 BW - 1 3.1
5.6.5 120mm x 160mm facing upwards m2 BW - 1 1.9
5.6.6 Grouted 10mm joint m2 BW - 1 1.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

6 ROOFING & WALL CLADING


Galvanized, corrugated or ribbed, steel sheet and
6.1 accessories
6.1.1 Guage 32 m2 RWC -1 52.O
6.1.2 Guage 30 m2 RWC -1 52.O
6.1.3 Guage 28 m2 RWC -1 52.O
6.1.4 Guage 26 m2 RWC -1 52.O
6.1.5 Guage 24 m2 RWC -1 52.O

Galvanized, colored corrugated or ribbed steel


6.2 roofing, on steel frame
6.2.1 Guage 26 m2 RWC -1 5O.O
6.2.2 Guage 24 m2 RWC -1 5O.O
Galvanized, colored corrugated or ribbed steel
roofing, factory insulated, 26 pauge with 25mm,
6.3 coloured m2 RWC -1 4O.O
Galvanized, colored corrugated or ribbed steel
roofing, factory insulated, 26 pauge with 25mm,
6.4 coloured m2 RWC -1 4O.O

Galvanized, corrgated or ribbed ridge roll, 250mm


6.5 wide m RWC -1 25O.O

Galvanized, corrgated or ribbed ridge roll, 500mm


6.6 wide m RWC -1 125.O

6.7 Flashing to parapet walls

6.7.1 Aluminium flashing, mill finish


6.7.1.1 100mm thick m2 1 Shee 9.O
6.7.1.2 400 " " m2 " 9.O
6.7.1.3 500 " " m2 " 9.O
6.7.1.4 800 " " m2 " 9.O
6.7.1.5 1000 " " m2 " 9.O
6.7.1.6 1200 " " m2 " 9.O
6.7.2 Stainless steel sheets
6.7.2.1 32ga, 250mm thick m2 " 9.6
6.7.2.2 28ga, 400 " " m2 " 9.6
6.7.2.3 26ga, 500 " " m2 " 9.6
6.7.2.4 24ga, 600 " " m2 " 9.6

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
6.8 Edge gutters with plain sheets (fixing)

6.8.1 Gutters, aluminium, 130mm,


6.8.1.1.4 box, 0.7mm thick, plain m 1 Shee 26.5
6.8.1.2 enamelled m 1 Shee 26.5

6.8.2 Stainless steel, half round or box m 1 Shee 26.5


6.8.2.1 100mm wide m 1 Shee 26.5
6.8.2.2 125mm wide m 1 Shee 26.5
6.8.3 Galvanized steel, half round or box m 1 Shee 26.5
6.8.3.1 100mm wide, plain m 1 Shee 26.5
6.8.3.2 125mm wide, plain m 1 Shee 26.5

6.8.4 Gutter guard, 150mm wide strip, aluminium


mesh m 1 Carp. 11O.O
6.9 Fixing and folding of vally gutters plain sheets
6.9.1 Guage 30, girth 700mm m RWC - 1 4O.O
6.9.2 Guage 28, girth 700mm m RWC - 1 4O.O
6.9.3 Guage 26, girth 700mm m RWC - 1 4O.O
6.9.4 Guage 24, girth 700mm m RWC - 1 4O.O

Cladding with galvanized stell sheet and


6.1 accessories m RWC - 1 27.5
6.10.1 Guage 28 m2 RWC - 1 27.5
6.10.2 Guage 26 m2 RWC - 1 27.5
6.10.3 Guage 24 m2 RWC - 1 27.5

Ridge cap out of galvanized plain steel sheet and


6.11 accessories
6.11.1 Guage 32, girth 400mm m RWC - 1 57.O
6.11.2 Guage 30, girth 400mm m RWC - 1 57.O
6.11.3 Guage 28, girth 400mm m RWC - 1 57.O
6.11.4 Guage 26, girth 400mm m RWC - 1 57.O
6.11.5 Guage 24, girth 400mm m RWC - 1 57.O

6.12 Fasica
Aluminium, reverse board & batter, 0.8mm thick,
6.12.1 coloured, no furring included m2 1 Shee 8.9
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
6.12.2 Steel, galv and enamelled, no furring included m2 1 Shee 8.9
6.12.2.1 long panels m2 1 Shee 8.9
6.12.3 Short panels m2 1 Shee 7.1

6.13 Downpipes

6.13.1 Steel, galvanized, square/round, m 1 Shee 38.5


6.13.1.1 50mm or 75mm diam, 28 guage m 1 Shee 29.5
6.13.1.2 100mm diameter, 28 guage m 1 Shee 26.5
6.13.1.3 125mm diameter, 28 guage m 1 Shee 26.5
6.13.4 125mm diameter, 26 guage m 1 Shee 26.5
6.13.1.5 150mm diameter, 28 guage m 1 Shee 26.5
6.13.6 150mm diameter, 26 guage m " 21.O
6.13.2 Steel, galvanized, rectangular m " 38.5
6.13.2.1 28 guage 50mm x 75mm m " 38.5
6.13.2.2 28 guage 75mm x 100mm m " 31.O
6.13.3 Wire Strainers, rectangular No " 85.O
6.13.3.1 50mm x 75mm No " 85.O
6.13.3.2 75mm x 100mm No " 85.O
6.13.4 Round strainers, 50mm or 75mm diameter No " 85.O
6.13.4.1 500mm or 75mm diameter No " 85.O
6.13.4.2 100mm diameter No " 85.O
6.13.4.3 125mm diameter No " 85.O
6.13.4.4 150mm diameter No " 85.O

Coping out of galvanized plin sheet and


6.14 accessories
6.14.1 Gauge 28, girth 500mm m RW - 2 4O.O
6.14.2 Gauge 26, girth 500mm m RW - 2 4O.O

Coping out of galvanized plin sheet and


6.15 accessories
6.15.1 Gauge 28, girth 700mm m RW - 2 42.5
6.15.2 " 26, " 700mm m RW - 2 42.5

6.16 Corrugated asbestos roofing


6.16.1 Corrugated asbestos roofing 6mm thick m2 RW - 2 25.O

6.17 Flat asbestos cladding


6.17.1 4mm thick m2 RW - 2 18.O
6.17.2 6mm thick m2 RW - 2 18.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

6.18 Asbestos ridge caps, flashing and aprons


6.18.1 Single piece m RWC - 2 35.O
6.18.2 Two pieces, adjustable close fitting m RWC - 2 3O.O
6.18.3 Flashing m RWC - 2 3O.O
6.18.4 Apron m RWC - 2 3O.O

6.19 Galvanized EGA ribbed sheet roofing


6.19.1 EGA 300mm thick m2 RWC - 2 26.5
6.19.2 EGA 400mm thick m2 RWC - 2 26.5
6.19.3 EGA 500mm thick m2 RWC - 2 26.5
6.19.4 EGA 600mm thick m2 RWC - 2 26.5
6.19.5 EGA 700mm thick m2 RWC - 2 26.5

6.2 Galvanized EGA ribbed sheet cladding


6.20.1 EGA 300mm thick m2 RWC - 2 23.5
6.20.2 EGA 400mm thick m2 RWC - 2 23.5
6.20.3 EGA 500mm thick m2 RWC - 2 23.5
6.20.4 EGA 600mm thick m2 RWC - 2 23.5

Galvanized EGA ribbed sheet ridge caps flashing


6.21 and accessories
6.21.1 0.4mm thick ridge caps, girth 700mm m2 RWC - 2 4O.O
6.21.2 0.4mm thick flashing, girth 700mm m2 RWC - 2 4O.O

6.23 Clay roof tiles and fittings


6.23.1 Roofing m2 RWC - 2 15.O
6.23.2 Ridge cap m2 RWC - 2 25.O

6.24 Natural fiber reinforced mortar roofing m2 RWC - 2 1O.O

6.25 PVC downpipes


6.25.1 Diameter 80mm m RWC - 2 32.5
6.25.2 Diameter 100mm m RWC - 2 3O.5
6.25.3 Diameter 150mm m RWC - 2 28.5
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

7 Waterproofing

7.1 Rooff waterproofing


7.1.1 Concrete primer m2 WP - 1 69.O
7.1.2 Heavy duty roof coating m2 WP - 1 41.O
7.1.3 Heavy duty patching compound m2 WP - 1 41.O
7.1.4 Roof membrane m2 WP - 1 6O.O
7.1.5 Bitumen damp proof course m2 WP - 1 31.O
7.1.6 Decorative (reflective) coat m2 WP - 1 27.O

Bentonite panels, 100mm x 100mm for walls,


7.2 5mm thick m2 1 Roofer 34.5

Bentonite panels, 100mm x 100mm under slabs,


7.3 16mm thick m2 1 Roofer 5O.O

7.4 Granular bentonite, 10mm thick trowlled on slabs m2 1 Roofer 26.O

7.5 Bituminous asphalt coating for foundation


7.5.1 Brushed, below grade
7.5.1.1 1 coat m2 1 Roofer 36.O
7.5.1.2 2 coat m2 1Roofer 27.O
7.5.2 Sprayed, below grade
7.5.2.1 1 coat 2.4m2/gall m2 1 Roofer 45.O
7.5.2.2 2 coat 1.9m2/gall m2 1Roofer 27.O
asphalt coating with fibres, trowelled on, asphalt
7.5.3 with asbestos
7.5.3.1 2mm thick m2 1Roofer 27.O
7.5.3.2 3mm thick m2 1Roofer 21.5
7.5.3.3 4mm thick m2 1Roofer 19.O
Asphalt primer, protective board, asphalt coated,
7.5.4 in mastic, 6mm thick m2 1Roofer 24.5
7.5.5 Membrane waterproffing omn slabs,
7.5.5.1 1 ply felt m2 WP - 2 165.O
7.5.5.2 2 ply felt m2 WP - 2 14O.O
7.5.5.3 3 ply felt m2 WP - 2 115.O
7..5.6 Membrane waterproofing on slabs
7.5.6.1 1 layer fabric m2 WP - 2 14O.O
7.5.6.2 2 layer fabric m2 WP - 2 9O.O
7.5.6.3 3 layer fabric m2 WP - 2 85.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

8 Carpentry and joinery

8.1 Post truss and rafter (from eucalyptus)


8.1.1 Truss, type 12m span No CJ - 1 3.O
8.1.1 Truss, type 8 - 10m span No CJ - 1 3.8
8.1.2 Rafter, diameter m CJ - 1 78.O
8.1.3 Purlin, diameter m CJ - 1 11O.O
Mounting eucalyptus truss with span ranging 8 to
8.1.4 12m No CJ - 2 5.8

8.2 Timber truss and rafters


Zigba truss fabrication 12m span with sections
8.2.1 50mm x 180mm No CJ - 1 1.O
8.2.2 Rafter, of various size m CJ - 1 4O.O
8.2.3 Purlin, of various size m CJ - 1 8O.O
Mounting woooden truss with span ranging 8 to
8.2.4 12m No CJ - 2 8.O

8.3 Post uprights, beams and bracings (eucalyptus)


8.3.1 Post uprights, of various diameter m CJ - 1 8O.O
8.3.2 Post beams, of various diameter m CJ - 2 1OO.O
8.3.3 Post bracing, of various diameter m CJ - 3 8O.O

8.4 Timber uprights, beams and bracings


8.4.1 Timber uprights, of various sizes m CJ - 1 5O.O
8.4.2 Timber beams, of various sizes m CJ - 2 7O.O
8.4.3 Timber bracings, of various sizes m CJ - 3 5O.O

8.5 Chipwood ceilling with battens


8.5.1 6mm thick, edges chamfered m2 CJ - 3 5.O
8.5.2 8mm thick, edges chamfered m2 CJ - 3 5.O

8.6 Softboard ceilling, of various thickness m2 CJ - 3 6.O

8.7 Hardboard ceiling, of various thicness m2 CJ - 3 6.O

8.8 Suspended ceilling


8.8.1 Chipboard, of various thickness m2 CJ - 3 6.O
8.8.2 Plywood, of various thickness m2 CJ - 3 5.5

8.9 Acoustic flat asbestos, of various thickness m2 CJ - 3 4.5


STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

8.1 Milled timber softfit


8.10.1 Tid wood, of various thickness m2 CJ - 3 6.O
8.10.2 Kerrero wood, of various thickness m2 CJ - 3 6.O
8.10.3 Woira wood, of various thickness m2 CJ - 3 6.O

8.11 Fascia and barge board


8.11.1 Kerero, of various width m CJ - 3 28.5
8.11.2 Tid, of various width m CJ - 3 28.5
8.11.3 Zigba, of various width m CJ - 3 28.5

8.12 Milled timber clading


8.12.1 Tid wood, of various thickness m2 CJ - 3 8.O
8.12.2 Kerrero wood, of various thickness m2 CJ - 3 8.O
8.12.3 Woira wood, of various thickness m2 CJ - 3 8.O

8.13 Galvanized sheet ceiling soffits


8.13.1 Flat sheet, of various thickness m2 CJ - 3 5.5
8.13.2 Ribbed sheet, of various thickness m2 CJ - 3 5.5
8.13.3 Corrugated sheet, of various thickness m2 CJ - 3 5.5

8.14 Floor boards


8.14.1 Tid wood, of various thickness m2 CJ - 3 8.5
8.14.2 Kerrero wood, of various thickness m2 CJ - 3 8.5
8.14.3 Woira wood, of various thickness m2 CJ - 3 8.5

8.15 Timber skirting 100mm high


8.15.1 Tid wood, of various thickness m CJ - 4 35.O
8.15.2 Kerrero wood, of various thickness m CJ - 4 35.O
8.15.3 Woira wood, of various thickness m CJ - 4 35.O

8.16 Various types of doors to be fixed into opening


with various areas

8.16.1 Glazed wooden doors m2 CJ - 3 5.5


8.16.2 Glazed wooden doors m2 CJ - 3 5.5
8.16.3 Glazed wooden doors m2 CJ - 3 5.5
Flush wooden doors to be fixed in to opening with
8.16.4 various areas
8.16.4.1 Kerero, type m2 CJ - 3 5.5
8.16.4.2 Woira, type m2 CJ - 3 5.5
8.16.4.3 Mahogany, type m2 CJ - 3 5.5
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

8.16.5 40mm flush wooden door, solid core 2.1m high


8.16.5.1 Commercial building
8.16.5.1.1 750mm wide No CJ - 5 5.3
8.16.5.1.2 800mm wide No CJ - 5 5.3
8.16.5.1.3 900mm wide No CJ - 5 5.3
8.16.5.1.4 1000mm wide No CJ - 5 5.3
8.16.5.1.5 1200mm wide No CJ - 5 4.6

8.16.5.2 Residential wooden door 2.0m high


8.16.5.2.1 Exterior
8.16.5.2.1.1 750mm wide No CJ - 5 4.8
8.16.5.2.1.2 800mm wide No CJ - 5 4.8
8.16.5.2.3 900mm wide No CJ - 5 4.8
8.16.5.2.4 1200mm wide No CJ - 5 4.4
8.16.5.2.2 Interior
8.16.5.2.2.1 750mm wide No CJ - 5 5.1
8.16.5.2.2.2 900mm wide No CJ - 5 5.1
8.16.5.2.2.3 1200mm wide No CJ - 5 4.7
8.16.5.2.2.4 1500mm wide No CJ - 5 4.3
8.16.5.2.2.5 1800mm wide No CJ - 5 3.9

8.17 Glazed wooden windows m2 CJ - 3 5.5


8.18 Panelled wooden windows m2 CJ - 3 5.5
8.19 Match boarded window m2 CJ - 3 5.5

8.2 Wall panels of various thickness


8.20.1 Kerero, tongued and grooved m2 CJ - 3 11.O
8.20.2 Tid, tongued and grooved m2 CJ - 3 11.O
8.20.3 Woira, tongued and grooved m2 CJ - 3 11.O
8.20.4 Kerero, open jointed board m2 CJ - 3 14.O
8.20.5 Tid, open jointed board m2 CJ - 3 14.O
8.20.6 Woira, open jointed board m2 CJ - 3 14.O
8.20.7 Kerero veneer, block board m2 CJ - 3 11.O
8.20.8 Tid, veneer, block board m2 CJ - 3 11.O
8.20.9 Woira veneer, block board m2 CJ - 3 11.O
8.20.10 Kerero veneer, flush panel m2 CJ - 3 12.5
8.20.11 Tid veneer, flush panel m2 CJ - 3 12.5
8.20.12 Woira veneer, flush panel m2 CJ - 3 12.5
Built-in cupboard, of various size covering various
8.21 areas of wall m2 CJ - 3 5.O
8.22 Balustreades and rails of various size m2 CJ - 3 6.5

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

8.23 Extra over partition panels for insulation


8.23.1 Mineral wool of various thickness m2 CJ - 3 17.5
8.23.2 Foam board of various thickness m2 CJ - 3 17.5
8.23.3 Rock wool of various thickness m2 CJ - 3 17.5

Residential wooden window, including frame and


8.24 glazing
8.24.1 900mm x 500mm No 2 carp 5.9
8.24.2 900mm x 1000mm No 2 carp 3.9
8.24.3 900mm x 1300mm No 2 carp 4.9
8.24.4 1300mm x 1800mm No 2 carp 3.4
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

9 structural steel work, mounting and fixing

9.1 Assembling of structural steel sections


9.1.1 Assembling of light structural steel sections
9.1.1.1 Stanchion kg SS - 1 4OO.O
9.1.1.2 Beams kg SS - 1 4OO.O
9.1.1.3 Trusses kg SS - 1 4OO.O
9.1.1.4 Purlins kg SS - 1 2OO.O
9.1.1.5 Ceiling support kg SS - 1 2OO.O
9.1.1.6 Bracing kg SS - 1 2OO.O
9.1.1.7 Rails kg SS - 1 2OO.O
9.1.1.8 Rafters kg SS - 1 2OO.O

9.1.2 Assembling of medium structural steel sections


9.1.2.1 Stanchion kg SS - 4 2OOO.O
9.1.2.2 Beams kg SS - 4 2OOO.O
9.1.2.3 Trusses kg SS - 4 2OOO.O
9.1.2.4 Purlins kg SS - 4 1OOO.O
9.1.2.5 Ceiling support kg SS - 4 1OOO.O
9.1.2.6 Bracing kg SS - 4 1OOO.O
9.1.2.7 Rails kg SS - 4 1OOO.O
9.1.2.8 Rafters kg SS - 4 1OOO.O

9.1.3 Assembling of heavy structural steel sections


9.1.3.1 Stanchion kg SS - 2 5OOO.O
9.1.3.2 Beams kg SS - 2 5OOO.O
9.1.3.3 Trusses kg SS - 2 5OOO.O
9.1.3.4 Purlins kg SS - 2 25OO.O
9.1.3.5 Ceiling support kg SS - 2 2OOO.O
9.1.3.6 Bracing kg SS - 2 2OOO.O
9.1.3.7 Rails kg SS - 2 2OOO.O
9.1.3.8 Rafters kg SS - 2 2OOO.O

9.2 Mounting and fixing of structural steel


Mounting and fixing of light structural steel
9.2.1 Manual
9.2.1.1 Stanchion kg SS - 1 8OO.O
9.2.1.2 Beams kg SS - 1 8OO.O
9.2.1.3 Trusses kg SS - 1 8OO.O
9.2.1.4 Purlins kg SS - 1 4OO.O
9.2.1.5 Ceiling support kg SS - 1 4OO.O
9.2.1.6 Bracing kg SS - 1 4OO.O
9.2.1.7 Rails kg SS - 1 4OO.O
9.2.1.8 Rafters kg SS - 1 4OO.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

Mounting and fixing of medium sturctural steel


9.2.2 winch or small crane
9.2.2.1 Stanchion kg SS - 4 4OOO.O
9.2.2.2 Beams kg SS - 4 4OOO.O
9.2.2.3 Trusses kg SS - 4 4OOO.O
9.2.2.4 Purlins kg SS - 4 25OO.O
9.2.2.5 Ceiling support kg SS - 4 2OOO.O
9.2.2.6 Bracing kg SS - 4 2OOO.O
9.2.2.7 Rails kg SS - 4 3OOO.O
9.2.2.8 Rafters kg SS - 4 3OOO.O

Mounting and fixing of heavysturctural steel 20 to


9.2.3 45 ton capacity crane
9.2.3.1 Stanchion kg SS - 2 1OOOO.O
9.2.3.2 Beams kg SS - 2 1OOOO.O
9.2.3.3 Trusses kg SS - 2 1OOOO.O
9.2.3.4 Purlins kg SS - 2 6OOO.O
9.2.3.5 Ceiling support kg SS - 2 4OOO.O
9.2.3.6 Bracing kg SS - 2 4OOO.O
9.2.3.7 Rails kg SS - 2 7OOO.O
9.2.3.8 Rafters kg SS - 2 7OOO.O

9.3 Plate fixing


9.3.1 Light
9.3.1.1 Connectiomn plate kg SS - 1 2OO.O
9.3.1.2 Base plate kg SS - 1 2OO.O
9.3.1.3 Angle ties kg SS - 1 2OO.O
9.3.1.4 Brackets kg SS - 1 2OO.O

9.3.2 Medium
9.3.2.1 Connectiomn plate kg SS - 4 3OO.O
9.3.2.2 Base plate kg SS - 4 3OO.O
9.3.2.3 Angle ties kg SS - 4 3OO.O
9.3.2.4 Brackets kg SS - 4 3OO.O
9.3.3 Heavy
9.3.3.1 Connectiomn plate kg SS - 2 4OO.O
9.3.3.2 Base plate kg SS - 2 4OO.O
9.3.3.3 Angle ties kg SS - 2 4OO.O
9.3.3.4 Brackets kg SS - 2 4OO.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

9.4 Fixing of bolts


9.4.1 Anchor bolts No. SS - 3 2O.O
9.4.2 M 16 No. SS - 3 3O.O
9.4.3 M 14 No. SS - 3 35.O
9.4.4 M 12 No. SS - 3 4O.O
9.4.5 M 10 No. SS - 3 45.O
9.4.6 M8 No. SS - 3 5O.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

10 Metal Work

10.1 Fixing into openning of various size


10.1.1 Galvanized steel profile
10.1.1.1 Metal doors m2 MW - 1 5.5
10.1.1.2.1 Metal doors frames 2.1m high (general)
10.1.1.2.1.1 700mm wide No MW - 3 4.7
10.1.1.2.1.2 800mm wide No MW - 3 4.7
10.1.1.2.1.3 900mm wide No MW - 3 4.7
10.1.1.2.1.4 1000mm wide No MW - 3 4.7
10.1.1.2.1.5 1500mm wide No MW - 3 4.2
10.1.1.2.1.6 1600mm wide No MW - 3 4.2
10.1.1.2.1.7 1800mm wide No MW - 3 4.2
10.1.1.2.1.8 2100mm wide No MW - 3 4.2
10.1.1.2.1.9 1200mm x 2400mm No MW - 3 3.6
10.1.1.2.1.10 2400mm x 2400mm No MW - 3 3.6
10.1.1.2.2 Howwlow metal doors 2.1m high plastic core
10.1.1.2.2.1 700mm wide No MW - 3 5.3
10.1.1.2.2.2 800mm wide No MW - 3 5.3
10.1.1.2.2.3 900mm wide No MW - 3 5.3
10.1.1.2.2.4 1000mm wide No MW - 3 5.3
10.1.1.2.2.5 1200mm x 2400mm No MW - 3 4.6

10.1.1.2 Metal windows m2 MW - 1 5.O


10.1.1.2.1 700mm x 1100mm No 2 Sswk 5.4
10.1.1.2.2 800mm x 1400mm No 2 Sswk 5.4
10.1.1.2.3 1100mm x 1600mm No 2Sswk 4.5
10.1.1.2.4 1200mm x 2000mm No 2 Sswk 3.2

10.1.1.3 Metal French Windows m2 MW - 1 5.5


10.1.2 Black or prepainted meld steel
10.1.2.1 Mild steel doors m2 MW - 1 5.5
10.1.2.2 Mild steel windows m2 MW - 1 5.5
10.1.2.3 Mild steel dfrench windows m2 MW - 1 5.5

10.1.3 Extruded aluminum profile


10.1.3.1 Aluminium doors m2 MW - 1 5.5
10.1.3.1.1 Aluminium doors frames 2.1m high
10.1.3.1.1.1 900mm wide No MW - 3 2.6
10.1.3.1.1.2 1800mm wide No MW - 3 2.3

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
10.1.3.2 Aluminum doors
10.1.3.1.2.1 900mm wide No 2 Sswk 2.O
10.1.3.1.2.2 1800mm wide No 2 Sswk 1.O

10.1.3.2 Aluminium windows


10.1.3.2.1 Aluminium windows frame
10.1.3.2.1.1 900mm x 1000mm No 2 Sswk 5.0
10.1.3.2.1.2 1300mm x 1600mm No 2 Sswk 4.0
10.1.3.2.2 Aluminium windows
10.1.3.2.2.1 900mm x 1000mm No 2 Sswk 2.O
10.1.3.2.2.2 1300mm x 1600mm No 2 Sswk 1.O

10.1.3.3 Aluminum french windows m2 MW - 1 5.5


10.1.3.4 Aluminum sliding glass doors m2 MW - 1 5.O
10.1.3.5 Aluminum sliding glass windows m2 MW - 1 5.O

10.1.4 Heavy duty sliding doors m2 MW - 1 4.5


10.1.5 Louver windows m2 MW - 1 5.5

10.2 Security grills out of:


10.2.1 metal steel block m2 MW - 2 5.5
10.2.2 Galvanized steel m2 MW - 2 5.5
10.2.3 Precoated solid plates m2 MW - 2 5.5
10.2.4 Hollow profile m2 MW - 2 5.5
10.2.5 Solid profile m2 MW - 2 5.5

10.3 Guard rails in :


10.3.1 Mild steel block m2 MW - 2 5.O
10.3.2 Galvanized steel m2 MW - 2 5.O
10.3.3 Aluminium m2 MW - 2 5.O
10.3.4 Timber and metal m2 MW - 2 5.O

10.4 Soffit fixer in:


10.4.1 Mild steel block m MW - 2 17.5
10.4.2 Galvanized steel m MW - 2 17.5
10.4.3 Aluminum m MW - 2 17.5

10.5 Wall fixer in:


10.5.1 Mild steel block m MW - 2 18.5
10.5.2 Galvanized steel m MW - 2 18.5
10.5.3 Aluminium m MW - 2 18.5

10.6 Wire netting in: m2


10.6.1 Galvanized steel wire m2 MW - 2 5.5
10.6.2 Aluminum wire m2 MW - 2 5.5

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
10.7 Fly Screen in:
10.7.1 Galvanized steel wire m2 MW - 2 5.5
10.7.2 aluminium wire m2 MW - 2 5.5
10.8 Corner Protection various size in:
10.8.1 Mild steel m MW - 2 17.5
10.8.2 Galvanized steel wire m MW - 2 17.5
10.7.1 Galvanized steel wire m2 MW - 2 5.5
10.7.2 aluminium wire m2 MW - 2 5.5
10.7.3 aluminium m MW - 2 17.5

10.9 Grating in:


10.9.1 Mild steel block m2 MW - 2 5.5
10.9.2 Galvanized steel m2 MW - 2 5.5
10.9.3 Chequered plate m2 MW - 2 5.5
10.9.4 Slotted plate m2 MW - 2 5.5

1O.1O Pit cover in:


10.10.1 Mild steel block m2 MW - 2 5.O
10.10.2 Galvanized steel m2 MW - 2 5.O
10.10.3 Chequered plate m2 MW - 2 5.O
10.10.4 Slotted plate m2 MW - 2 5.O

10.11 Ladders in:


10.11.1 Mild steel, girth m MW - 1 8.O
10.11.2 Galvanized steel m MW - 1 8.O
10.11.3 RHS, m MW - 1 8.O
10.11.4 Solid steel m MW - 1 8.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

11 Plastering and pointing

11.1 Two coats of compomortar to internal surface


11.1.1 Brick wallls m2 PP - 1 7.O
11.1.2 Hollow concrete block walls m2 PP - 1 7.O
11.1.3 Stone masonry surfaces m2 PP - 1 6.O
11.1.4 Concrete vertical surfaces m2 PP - 1 7.O
11.1.5 Concrete soffits m2 PP - 1 5.O

11.2 Two coats of cement mortar to internal surface


11.2.1 Brick wallls m2 PP - 1 7.O
11.2.2 Hollow concrete block walls m2 PP - 1 7.O
11.2.3 Stone masonry surfaces m2 PP - 1 6.O
11.2.4 Concrete vertical surfaces m2 PP - 1 7.O
11.2.5 Concrete soffits m2 PP - 1 5.O

11.3 Two coats of compomortar to external surface


11.3.1 Brick wallls m2 PP - 1 7.O
11.3.2 Hollow concrete block walls m2 PP - 1 7.O
11.3.3 Stone masonry surfaces m2 PP - 1 6.O
11.3.4 Concrete vertical surfaces m2 PP - 1 7.O
11.3.5 Concrete soffits m2 PP - 1 5.O

11.4 Two coats of cement mortar to external surface


11.4.1 Brick wallls m2 PP - 1 7.O
11.4.2 Hollow concrete block walls m2 PP - 1 7.O
11.4.3 Stone masonry surfaces m2 PP - 1 6.O
11.4.4 Concrete vertical surfaces m2 PP - 1 7.O
11.4.5 Concrete soffits m2 PP - 1 6.O

11.5 Fine coat of lime plaster


11.5.1 Internal plastered vertical surface m2 PP - 2 15.O
11.5.2 Internal plastered soffits m2 PP - 2 1O.O
11.5.3 External plastered vertical surface m2 PP - 2 15.O
11.5.4 External plastered soffit m2 PP - 2 1O.O

11.6 Fine coat of gypsum plaster


11.6.1 Internal plastered vertical surface m2 PP - 2 15.O
11.6.2 Internal plastered soffits m2 PP - 2 1O.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
11.6.3 External plastered vertical surface m2 PP - 2 15.O
11.6.4 External plastered soffit m2 PP - 2 1O.O

11.7 Fine coat cement plaster


11.7.1 Internal plastered vertical surface m2 PP - 2 15.O
11.7.2 Internal plastered soffits m2 PP - 2 1O.O
11.7.3 External plastered vertical surface m2 PP - 2 15.O
11.7.4 External plastered soffit m2 PP - 2 1O.O

11.8 Final coat rendered


11.8.1 Internal plastered vertical surface m2 PP - 2 2O.O
11.8.2 Internal plastered soffits m2 PP - 2 16.O
11.8.3 External plastered vertical surface m2 PP - 2 2O.O
11.8.4 External plastered soffit m2 PP - 2 16.O

11.9 Final coloured coat rendered


11.9.1 Internal plastered vertical surface m2 PP - 2 18.O
11.9.2 Internal plastered soffits m2 PP - 2 14.O
11.9.3 External plastered vertical surface m2 PP - 2 18.O
11.9.4 External plastered soffit m2 PP - 2 14.O

11.1O Recessed cement pointings


11.10.1 Brick wall m2 PP - 3 6.5
11.10.2 Hollow concrete block wall m2 PP - 3 13.O
11.10.3 Rough dressed stone wall m2 PP - 3 19.O

11.11 Flush cement pointing


11.11.1 Brick wall m2 PP - 3 8.O
11.11.2 Hollow concrete block wall m2 PP - 3 16.O
11.11.3 Rough dressed stone wall m2 PP - 3 8.5
11.11.4 Dressed stone wall m2 PP - 3 7.O

11.12 Chiselling
11.12.1 Surface
11.12.1.1 Concrete floor slab m2 1 Chisler 15.O
11.12.1.2 Concrete vertical surface m2 1 Chisler 1O.O
11.12.1.3 Concrete soffit m2 1 Chisler 5.O

11.13 Three coats 25mm thick plastering


11.13.1 On frame construction float finish m2 PP - 4 56.O
11.13.2 On frame constructiontrowlfinish m2 PP - 4 5O.O
11.13.3 On masonry construction m2 PP - 4 59.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

11.14 Three coats 19mm thick plastering


11.14.1 On frame construction float finish m2 PP - 4 61.O
11.14.2 On frame construction trowl finish m2 PP - 4 55.O
11.14.3 On frame construction for soffits m2 PP - 4 39.O

11.15 Gypsum plaster


11.15.1 2 coats on wall m2 PP - 4 88.O
11.15.2 2coats on ceiling m2 PP - 4 77.O
11.15.3 2 coats on wall m2 PP - 4 73.O
11.15.4 2 coats on ceiling m2 PP - 4 65.O

1.16 Thin coat plaster, local veneer m2 PP - 4 3OO.O


STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

12 floor and wall finish

12.1 Precast cement floor tiles


12.1.1 Size 200mm x 200mm x 20mm m2 FWF - 1 1O.O
12.1.2 Size 250mm x 250mm x 20mm m2 FWF - 1 1O.O
12.1.3 Size 200mm x 200mm x 20mm, slip resistant m2 FWF - 1 1O.O
12.1.4 Size 250mm x 250mm x 20mm, slip resistant m2 FWF - 1 1O.O
12.1.5 Size 100mm x 20mm skirting m2 FWF - 1 2O.O

12.2 Terrazzo floor tiles


12.2.1 Size 200mm x 200mm x 20mm m2 FWF - 1 1O.O
12.2.2 Size 250mm x 250mm x 20mm m2 FWF - 1 1O.O
12.2.3 Size 300mm x 300mm x 20mm m2 FWF - 1 1O.O
12.2.4 Size 300mm x 300mm x 25mm m2 FWF - 7 1O.O
12.2.5 Size 300mm x 300mm x 30mm m2 FWF - 1 1O.O
12.2.6 Size 400mm x 400mm x 30mm m2 FWF - 7 1O.O
12.2.7 Size 400mm x 400mm x 40mm m2 FWF - 7 1O.O
12.2.8 Size 100mm x 20mm skirting m2 FWF - 1 2O.O
12.2.9 Size 150mm x 20mm skirting straight m 1Tiler 15.O
12.2.10 Size 150mm x 20mm skirting curved m 1Tiler 13.5
12.2.11 Size 200mm x 20mm skirting straight m 1Tiler 14.O
12.2.12 Size 200mm x 20mm skirting curved m 1Tiler 11.O

12.3 Marble floor tiles


12.3.1 30mm thick "Harrer Dalecha" m2 FWF - 2 7.O
12.3.2 20mm thick "Harrer Dalecha" m2 FWF - 2 7.O
12.3.3 30mm thick "Gojam Grey " m2 FWF - 2 7.O
12.3.4 20mm thick "Gojam Grey " m2 FWF - 2 7.O
12.3.5 30mm thick "Wollega Grey" Daleti m2 FWF - 2 7.O
12.3.6 20mm thick "Wollega Grey" Daleti m2 FWF - 2 7.O
12.3.7 30mm thick "Wollega White" Bokea m2 FWF - 2 7.O
12.3.8 30mm thick "Wollega White" Bokea m2 FWF - 2 7.O

12.4 Skirting
12.4.1 Size 70mm x 15mm "Harrer Dalecha" m FWF - 2 17.O
12.4.2 Size 70mm x 15mm "Gojam Grey" m FWF - 2 17.O
12.4.3 Size 70mm x 15mm "Wollega Grey" Daleti m FWF - 2 17.O
12.4.4 Size 70mm x 15mm "Wollega Grey" Bokea m FWF - 2 17.O

12.5 Ceramic floor Tiles


12.5.1 15mm thick white m2 FWF - 2 1O.O
12.5.2 15mm thick coloured m2 FWF -2 1O.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
12.6 Mosaci Floor Tiles Size 25mm x 25mm m2 FWF - 2 12.0

12.7 Cement screed floor finish


12.7.1 50mm thick trowel finished m2 FWF - 4 12.O
12.7.2 40mm thick smooth finished m2 FWF - 4 12.O
12.7.3 48mm thick smooth finished m2 FWF - 4 12.O
12.7.4 34mm thick smooth finished m2 FWF - 4 12.O
12.7.5 30mm thick trowel finished m2 FWF - 4 12.O
12.7.6 30mm thick smoothfinished m2 FWF - 4 12.O

12.8 Cement screed sub - floor


12.8.1 20mm thick m2 FWF - 4 15.O
12.8.2 30mm thick m2 FWF - 4 13.O
12.8.3 48mm thick m2 FWF - 4 12.O

12.9 Marble chips flooring m2 FWF - 3 5.O

12.1O Earth floor 200mm thick compacted m2 1 lab 5.O

12.11 PVC Tile and Skirting


12.11.1 2mm thick tile m2 FWF - 5 16.O
12.11.2 1.6mm thick tile m2 FWF - 5 16.O
12.11.3 100mm high skirting m FWF - 5 45.O
12.11.4 80mm high skirting m FWF - 5 45.O
12.11.5 60mm high skirting m FWF - 5 45.O

12.12 Ceramic and Mosaic Wall Tiles

12.12.1 6mm thick white/coloured ceramic


12.12.1.1 100mm x 100mm ceramic tiles m2 FWF - 6 3.8
12.12.1.2 100mm x 150mm ceramic tiles m2 FWF - 6 4.O
12.12.1.3 100mm x 200mm ceramic tiles m2 FWF - 6 4.O
12.12.1.4 150mm x 150mm ceramic tiles m2 FWF - 6 4.3
12.12.1.5 300mm x 300mm ceramic tiles m2 FWF - 6 5.2
12.12.2 Mosaic on 200x200 tiles m2 FWF - 6 4.0
12.13 Dividing Strips for Floors
12.13.1 Metal strips m FWF - 5 45.O
12.13.2 Rubber strips m FWF - 5 45.O
12.13.3 Plastic strips m FWF - 5 45.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
12.14 Coppings of variable width
12.14.1 20mm terrazzo m FWF - 1 15.O
12.14.2 20mm "Harrer dalecha" m FWF - 1 15.O
12.14.3 20mm "Gojam Grey" m FWF - 1 15.O
12.14.4 20mm "Wollega Grey" m FWF - 1 15.O
12.14.5 20mm "Wollega White" m FWF - 1 15.O
12.14.6 50mm concrete m FWF - 1 15.O
12.14.7 50mm dressed stone m FWF - 1 15.O

12.15 Sills of variable width


12.15.1 20mm terrazzo m FWF - 1 15.O
12.15.2 20mm "Harrer dalecha" m FWF - 1 15.O
12.15.3 20mm "Gojam Grey" m FWF - 1 15.O
12.15.4 20mm "Wollega Grey" m FWF - 1 15.O
12.15.5 20mm "Wollega White" m FWF - 1 15.O
12.15.6 30mm concrete m FWF - 1 15.O
12.15.7 50mm dressed stone m FWF - 1 15.O

12.16 Treads of steps


12.16.1 20mm thick terrazzo m2 FWF - 1 1O.O
12.16.2 30mm thick terrazzo m2 FWF - 1 1O.O
12.16.3 40mm thick terrazzo & less than 400mm wide m 2 Tilers 2O.5
12.16.4 50mm thick terrazzo & less than 400mm wide m 2Tilers 19.5
12.16.5 20mm thick "Harrer" marble m2 FWF - 1 7.O
12.16.6 20mm thick "Gojam grey" marble m2 FWF - 1 7.O
12.16.7 20mm thick "Wollega grey" marble m2 FWF - 1 7.O
12.16.8 30mm thick "Wollega white" marble m2 FWF - 1 7.O
12.16.9 20mm thick "Wollega white" marble m2 FWF - 1 7.O
12.16.10 30mm thick concrete m2 FWF - 1 1O.O
12.16.11 50mm thick dressed stone m2 FWF - 2 1O.O

12.17 Risers of steps


12.17.1 20mm thick terrazzo m2 FWF - 1 9.O
12.17.2 20mm thick harrer marble m2 FWF - 1 9.O
12.17.3 20mm thick Gojam marble grey m2 FWF - 1 9.O
12.17.4 20mm thick Wollega marble grey m2 FWF - 1 9.O
12.17.5 20mm thick Wollega marble white m2 FWF - 1 9.O
12.17.6 25mm thick 150 high straight sections m 2 Tilers 45.O
12.17.7 25mm thick 150 high curved sections m 2 Tilers 45.O

12.18 Stone paving


12.18.1 Roughly dressed m2 SM - 1 12.O
12.18.2 Dressed m2 SM - 2 12.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

12.19 Concrete paving


12.19.1 50mm thick in situ concrete m2 C - 10 2O.O
12.19.2 50mm thick precast concrete m2 SM - 2 2O.O
12.19.3 80mm thick in situ concrete m2 C - 10 15.O
12.19.4 80mm thick precast concrete m2 SM - 2 15.O
12.19.5 100mm thick in situ concrete m2 C - 10 1O.O

12.2O Carpet floor finish m2 FWF - 5 15.O


STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

13 Painting

13.1 Oil Paint (3 coats including primer)


13.1.1 Plastered vertical surface m2 P-1 15.O
13.1.2 Pointed vertical surface m2 P-1 15.O
13.1.3 Rendered vertical surface m2 P-1 15.O
13.1.4 Fair faced vertical surface m2 P-1 15.O
13.1.5 Hammered vertical surface m2 P-1 15.O
13.1.6 Plasterd soffits m2 P-1 12.O
13.1.7 Rendered soffits m2 P-1 12.O
13.1.8 Fair faced soffits m2 P-1 12.O
13.1.9 Hammered soffits m2 P-1 12.O
13.1.10 Timber partition m2 P-1 15.O
13.1.11 Metal surface m2 P-1 15.O
13.2 Plastic emulation paint (3 coats including primer)
13.2.1 Mat finish
13.2.1 Plastered vertical surface m2 P-1 2O.O
13.2.2 Pointed vertical surface m2 P-1 2O.O
13.2.3 Rendered vertical surface m2 P-1 2O.O
13.2.4 Fair faced vertical surface m2 P-1 2O.O
13.2.5 Hammered vertical surface m2 P-1 2O.O
13.2.6 Plasterd soffits m2 P-1 19.O
13.2.7 Rendered soffits m2 P-1 19.O
13.2.8 Fair faced soffits m2 P-1 19.O
13.2.9 Hammered soffits m2 P-1 19.O
13.2.10 Timber partition m2 P-1 25.O

13.2.2 Glossy Finish


13.2.2.1 Plastered vertical surface m2 P-1 22.O
13.2.2.2 Pointed vertical surface m2 P-1 22.O
13.2.2.3 Rendered vertical surface m2 P-1 22.O
13.2.2.4 Fair faced vertical surface m2 P-1 22.O
13.2.2.5 Hammered vertical surface m2 P-1 22.O
13.2.2.6 Plasterd soffits m2 P-1 17.O
13.2.2.7 Rendered soffits m2 P-1 17.O
13.2.2.8 Fair faced soffits m2 P-1 17.O
13.2.2.9 Hammered soffits m2 P-1 17.O
13.2.2.10 Timber partition m2 P-1 22.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
13.2.3 Oilbased paint
13.2.3.1 Timber surface m2 P-1 25.O
13.2.3.2 Metalsurface m2 P-1 25.O

13.3 Painting on brick/concrete surface


13.3.1 Primer + 1 coat m2 1 Painter II 22.O
13.3.2 Primer + 2 coat m2 1 Painter II 16.O
13.3.3 Filler + 1 coat m2 1 Painter II 21.O
13.3.4 Filler + 2 coat m2 1 Painter II 15.5

13.4 wood sidings (including puttying)


13.4.1 Primer + 1 coat m2 1 Painter II 3O.O
13.4.2 Primer + 2 coat m2 1 Painter II 21.O

13.5 Windows & doors


13.5.1 Primer + 1 coat m2 1 Painter II 18.O
13.5.2 Primer + 2 coat m2 1 Painter II 11.O

13.6 Interior painting on plaster (brush work)


13.6.1 Primer + 1 coat m2 1 Painter II 2O.O
13.6.2 Primer + 2 coat m2 1 Painter II 14.O
13.6.3 Primer + 3 coat m2 1 Painter II 1O.O

13.7 Interior painting on plaster (roller work)


13.7.1 Walls & ceilings
13.7.2 Primer + 1 coat m2 1 Painter II 37.5
13.7.3 Primer + 2 coat m2 1 Painter II 26.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

14 Glazing

14.1 Clear sheet glass


14.1.1 3mm thick m2 G-1 12.5
14.1.2 4mm thick m2 G-1 12.5
14.1.3 5mm thick m2 G-1 1O.5
14.1.4 5mm thick m2 2 Galzier 1O.5
14.1.5 6mm thick m2 G-1 1O.5
14.1.6 6mm thick m2 2 Galzier 9.5
14.1.7 8mm thick m2 2 Galzier 7.5
14.1.8 10mm thick m2 2 Galzier 6.O
14.1.9 12mm thick m2 2 Galzier 4.5
14.1.10 16mm thick m2 2 Galzier 3.5
14.1.11 20mm thick m2 2 Galzier 2.5
14.1.12 25mm thick m2 2 Galzier 2.5

14.2 Figured glass (obscure glass)


14.2.1 3mm thick m2 2 Galzier 11.O
14.2.2 4mm thick m2 G-1 1O.O
14.2.3 5mm thick m2 G-1 1O.O
14.2.4 6mm thick m2 G-1 9.O
14.2.5 6mm thick m2 2 Galzier 9.O

14.3 Opat glass


14.3.1 3mm thick m2 G-1 12.O
14.3.2 4mm thick m2 G-1 12.O
14.3.3 5mm thick m2 G-1 1O.O
14.3.4 6mm thick m2 G-1 1O.O

14.4 Wired glass


14.4.1 4mm thick m2 G-1 12.O
14.4.2 5mm thick m2 G-1 1O.O
14.4.3 6mm thick m2 G-1 1O.O
14.4.4 6mm thick m2 2 Glazier 11.O

14.5 Glass block


14.5.1 5mm thick m2 G-1 1O.O
14.5.2 6mm thick m2 G -1 1O.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

14.6 Window glass


14.6.1 2.4mm thick, clear m2 2 Glazier 16.O
14.6.2 3mm thick, clear m2 2 Glazier 16.O
14.6.3 Tinted m2 2 Glazier 16.O
14.6.4 Tempered m2 2 Glazier 16.O

14.7 Glass mirrors


14.7.1 Polished plate glass, mirror No G-1 1O.O
14.7.2 Wall type 6mm upto 0.5m2 m2 2 Glazier 1O.O
14.7.3 Wall type 6mm upto 1.4m2 m2 2 Glazier 12.5
14.8 Spanderl glass
14.8.1 Over 20m2 m2 2 Glazier 9.O
14.8.2 Under 20m2 m2 2 Glazier 9.O

14.9 Glass Wall tiles 300mm x 300mm m2 2 Glazier 15.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

15 Sanitary installation

15.1 Galvanized steel pipes


15.1.1 Galvanized steel pipes treated joints
15.1.1.1 Diameter, 1/4" m 1 Plumber 15.O
15.1.1.2 Diameter, 3/8" m 1 Plumber 15.O
15.1.1.3 Diameter, 1/2" m 1 Plumber 14.O
15.1.1.4 Diameter, 3/4" m 1 Plumber 14.O
15.1.1.5 Diameter, 1" m 1 Plumber 12.O
15.1.1.6 Diameter, 11/4" m SI - 1 2O.O
15.1.1.7 Diameter, 11/2" m SI - 1 18.O
15.1.1.8 Diameter, 2" m SI - 1 15.O
15.1.1.9 Diameter, 21/2" m SI - 1 11.O

15.1.2 Galvanized steel pipes bell & spigot joints


15.1.2.1 Diameter, 3" m SI - 1 9.7
15.1.2.2 Diameter, 31/2" m SI - 1 9.O
15.1.2.3 Diameter, 4" m SI - 1 8.2
15.1.2.4 Diameter, 5" m SI - 1 7.5
15.1.2.5 Diameter, 6" m SI - 1 6.7
15.1.2.6 Diameter, 8" m SI - 1 6.O
15.1.2.7 Diameter, 10" m SI - 1 5.2
15.1.2.8 Diameter, 12" m SI - 1 3.7

Cast iron pipes for sewage, on hangers, with


15.2 1500mm c/c bell & spigot joints, 3000mm c/c
15.2.1 Diameter, 2" m SI - 1 11.O
15.2.2 Diameter, 3" m SI - 1 11.O
15.2.3 Diameter, 4" m SI - 1 9.6
15.2.4 Diameter, 5" m SI - 1 14.O
15.2.5 Diameter, 6" m SI - 1 13.5
15.2.6 Diameter, 8" m SI - 1 11.O
15.2.7 Diameter, 10" m SI - 1 1O.5
15.2.8 Diameter, 12" m SI - 1 9.O

15.3 UPVC pipes for cold water & sewerage


15.3.1 Diametere, 1/4" m 1 Plumber 11.5
15.3.2 Diametere, 3/8" m 1 Plumber 11.O
15.3.3 Diametere, 1/2" m 1 Plumber 1O.O
15.3.4 Diametere, 3/4" m 1 Plumber 7.9
15.3.5 Diametere, 1" m 1 Plumber 7.2
15.3.6 Diametere, 11/4" m 1 Plumber 6.5
15.3.7 Diametere, 11/2" m 1 Plumber 5.8

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

15.3.8 Diameter, 2" m SI - 1 1O.O


15.3.9 Diameter, 21/2" m SI - 1 9.4
15.3.10 Diameter, 3" m SI - 1 8.6
15.3.11 Diameter, 4" m SI - 1 7.2
15.3.12 Diameter, 5" m SI - 1 7.2
15.3.13 Diameter, 6" m SI - 1 6.5

15.4 UPVC pipes for pool and surface draining


15.4.1 Diameter, 21/2" m SI - 1 9.6
15.4.2 Diameter, 3" m SI - 1 8.9
15.4.3 Diameter, 4" m SI - 1 7.4
15.4.4 Diameter, 5" m SI - 1 7.4
15.4.5 Diameter, 6" m SI - 1 6.6

Copper pipes (soldered joints with hangers at


15.5 1500mm c/c)
15.5.1 Diameter, 1/4" m 1 Plumber 13.5
15.5.2 Diameter, 3/8" m 1 Plumber 13.O
15.5.3 Diameter, 1/2" m 1 Plumber 12.O
15.5.4 Diameter, 5/8" m 1 Plumber 11.5
15.5.5 Diameter, 3/4" m 1 Plumber 9.8
15.5.6 Diameter, 1" m 1 Plumber 8.3
15.5.7 Diameter, 11/4" m 1 Plumber 6.8
15.5.8 Diameter, 11/2" m 1 Plumber 6.1
15.5.9 Diameter, 2" m 1 Plumber 5.3
15.5.10 Diameter, 21/2" m SI - 1 7.6
15.5.11 Diameter, 3" m SI - 1 6.8
15.5.12 Diameter, 31/2" m SI - 1 6.4
15.5.13 Diameter, 4" m SI - 1 5.3
15.5.14 Diameter, 5" m SI - 1 4.5
15.5.15 Diameter, 6" m SI - 2 5.3
15.5.16 Diameter, 8" m SI - 2 4.5

15.6 Wash down water closet


15.6.1 White vitreous China W.C
15.6.1.1 With low level flush/close coupler No. SI - 1 3.O
15.6.1.2 With high level flush cistern No. SI - 1 2.5

15.6.2 Enamelled white cast iron


15.6.2.1 Pedstal pan WC unit No. SI - 1 3.O
15.6.2.2 Squatting pan WC No. SI - 1 2.5

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
15.6.3 Precast terrazzo squatting pan WC No. SI - 1 2.5

15.7 Wash hand basin


15.7.1 white vitreous china w.h.b.
15.7.1.1 For cold water No. SI - 1 3.O
15.7.1.2 For hot & cold water No. SI - 1 3.O
15.7.1.3 For hot & cold water & mixer No. SI - 1 3.O
15.7.2 white vitreous china w.h.b, with pedestal
15.7.2.1 For cold water No. SI - 1 3.O
15.7.2.2 For hot & cold water No. SI - 1 3.O
15.7.2.3 For cold & hotwater & mixer No. SI - 1 3.O

15.8 Urinals (wall hung) & self closing valves


15.8.1 White vitreous china urinal bowl No. SI - 1 2.3
15.8.2 Rough in supply waste and vent No. SI - 1 1.9
15.8.3 Stall type, Viterious china, includes valve No. SI - 1 1.9
15.8.4 Ditto as in (15.8.2) but with 75mm seam cover No. SI - 1 1.8
15.8.5 Ditto as in (15.8.3) but with 150mm seam cover No. SI - 1 1.5

15.9 Bath Tub


15.9.1 Standard white enamelled steel bath tub
15.9.1.1 1400mm No. SI - 1 3.1
15.9.1.2 1500mm No. SI - 1 2.9

15.9.2 standard white enamelled cast iron bath tub


15.9.2.1 1050mm x 900mm No. SI - 1 2.3
15.9.2.2 1200mm x 1050mm No. SI - 1 1.8
15.9.2.3 1800mm x 900mm No. SI - 1 1.4
15.9.3 standard white, reinforced acrylic bath tub
15.9.3.1 1000mm x 1000mm No. SI - 1 3.1
15.9.3.2 1700mm x 900mm No. SI - 1 2.9

15.1 Electric water heater (residential)


15.10.1 Capacity, 50lts No. 1 Plumber 1.5
15.10.2 Capacity, 80lts No. 1 Plumber 1.5
15.10.3 Capacity, 100lts No. 1 Plumber 1.5
15.10.4 Capacity, 150lts No. 1 Plumber 1.3
15.10.5 Capacity, 400lts No. 1 Plumber O.9

15.11 Shower tray


15.11.1 Shower tray in white enamelled steel No. SI - 1 2.5
15.11.2 Shower tray in precast terrazzo No. SI - 1 2.5
15.11.3 Fiberglass with 3 walls

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
15.11.3.1 For 800mm x 800mm shower tray No. SI - 1 O.5
15.11.3.2 For 900mm x 900mm shower tray No. SI - 1 O.5
No.
15.12 Sinks, with faucets and drains No.
15.12.1 Steel sink single bowl, size (600mm x 500mm) No. SI - 1 2.3
15.12.2 Steel sink single bowl, size (750mm x 500mm) No. SI - 1 2.3
15.12.3 Steel sink single bowl, size (800mm x 500mm) No. SI - 1 1.9
15.12.4 Steel sink single bowl, size (1100mm x 500mm) No. SI - 1 1.9
Stainless steel sink, single bowl, size 480mm x
15.12.5 450mm No. SI - 1 2.3
Stainless steel sink, single bowl, size 650mm x
15.12.6 550mm No. SI - 1 2.3
15.12.7 Stainless steel sink, double bowl, size No. SI - 1 2.O
Stainless steel sink, double bowl, double drain,
15.12.8 size No. SI - 1 2.O
15.12.9
single bowl 610mm x 500mm No. SI - 1 3.2
Double bowl 810mm x 500mm No. SI - 1 2.6

15.13 Laundary Sinks


15.13.1 Procelain enamel or castiron, with iron frame
15.13.1.1 Single compartment 600mm x 500mm No. SI - 1 3.O
15.13.1.2 Single compartment 600mm x 600mm No. SI - 1 3.O

15.13.2 Molded stone on wall hangers orlegs


15.13.2.1 Single compartement 600mm x 500mm No. SI - 1 3.O
15.13.2.2 Double compartement 1100mm x 500mm No. SI - 1 2.5

15.13.3 Terrazo laundary sinks of various size No. SI - 1 2.O

15.14 Other accessories


15.14.1 Toilet roll, chrom plated No. 1 Plumber 7.O
15.14.2 Toilet roll, white vitreous china No. 1 Plumber 7.O
15.14.3 Soap holder, chromium plated No. 1 Plumber 7.O
15.14.4 Soap holder, white vitreous china No. 1 Plumber 7.O
15.14.5 Towel rail No. 1 Plumber 7.O
15.14.6 Towel hooks No. 1 Plumber 7.O
15.14.7 Shower curtain track m 1 Plumber 6.O
15.14.8 Plastic shower curtain, 1800 high m 1 Plumber 6.O

15.15 Faucets (double outlet, or center set)


15.15.1 Bath, faucets, diverted spout continuation, sweat No. 1 Plumber 5.8
15.15.2 Kitchen sink faucets, top mount cast spout No. 1 Plumber 7.2

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
Laundary faucets, shelf type iron pipe or copper
15.15.3 union No. 1 Plumber 8.7
15.15.4 Hand wash basin centerset, without drain No. 1 Plumber 7.2
15.16 Water supply meters
15.16.1 Both sides threaded
15.16.1.1 5/8" diameter to 20 gallons per minute No. 1 Plumber 12.O
15.16.1.2 3/4" diameter to 30 gallons per minute No. 1 Plumber 1O.5
15.16.1.3 1" diameter to 50 gallons per minute No. 1 Plumber 9.1

15.16.2 One side threaded one side flanged


15.16.2.1 1/2" diameter to 100 gallons per minute No. 1 Plumber 5.6
15.16.2.2 2" diameter to 160 gallons per minute No. 1 Plumber 4.2

15.16.3 Both sides Flanged


15.16.3.1 3" diameter to gallons per minute No. SI - 1 2.O
15.16.3.2 4" diameter to gallons per minute No. SI - 1 1.O
15.16.3.3 6" diameter to gallons per minute No. SI - 1 O.7
15.16.3.4 8" diameter to gallons per minute No. SI - 1 O.5

15.17 Floar drains & traps

15.17.1 Floar drains


15.17.1.1 Diameter, 1/2" No. 1 Plumber 8.OO
15.17.1.2 Diameter, 3/4" No. 1 Plumber 7.OO
15.17.1.3 Diameter, 1" No. 1 Plumber 7.OO
15.17.1.4 Diameter, 11/4" No. 1 Plumber 6.OO
15.17.1.5 Diameter, 11/2" No. 1 Plumber 6.OO
15.17.1.6 Diameter, 2" No. SI - 1 9.9
15.17.1.7 Diameter, 3" No. SI - 1 9.9
15.17.1.8 Diameter, 4" No. SI - 1 7.4
15.17.1.9 Diameter, 5" No. SI - 1 7.4
15.17.1.10 Diameter, 6" No. SI - 1 7.4

15.17.2 Standard trap


15.17.2.1 Diameter, 11/4" No. SI - 1 13.O
15.17.2.2 Diameter, 11/2" No. SI - 1 12.5
15.17.2.3 Diameter, 2" No. SI - 1 11.O
15.17.2.4 Diameter, 3" No. SI - 1 7.9

15.17.3 Deep-seal trap


15.17.3.1 Diameter, 11/4" No. SI - 1 1O.O
15.17.3.2 Diameter, 11/2" No. SI - 1 1O.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
15.17.3.3 Diameter, 2" No. SI - 1 1O.O
15.17.3.4 Diameter, 3" No. SI - 1 8.7

15.17.4 Drum trap


15.7.4.1 4"diameter & 5" deep
17.15.4.1.1 Diameter, 11/2" No. SI - 2 1O.1
17.15.4.1.2 Diameter, 2" No. SI - 2 1O.2
15.17.4.2 4"diameter & 8" deep
15.17.4.2.1 Diameter, 11/2" No. SI - 2 7.7
15.17.4.2.2 Diameter, 2" No. SI - 2 7.7

15.18 Pipe fittings various types

15.18.1 Both sides threaded


15.18.1.1 Diameter, 1/4" No. 1 Plumber 24.O
15.18.1.2 Diameter, 3/8" No. 1 Plumber 24.O
15.18.1.3 Diameter, 1/2" No. 1 Plumber 24.O
15.18.1.4 Diameter, 3/4" No. 1 Plumber 2O.O
15.18.1.5 Diameter, 1" No. 1 Plumber 2O.O
15.18.1.6 Diameter, 11/4" No. 1 Plumber 16.O
15.18.1.7 Diameter, 11/2" No. 1 Plumber 13.O
15.18.1.8 Diameter, 2" No. 1 Plumber 1O.O

15.18.2 One side threaded, one side free


15.18.2.1 Diameter, 1/4" No. 1 Plumber 24.O
15.18.2.2 Diameter, 3/8" No. 1 Plumber 24.O
15.18.2.3 Diameter, 1/2" No. 1 Plumber 24.O
15.18.2.4 Diameter, 3/4" No. 1 Plumber 2O.O
15.18.2.5 Diameter, 1" No. 1 Plumber 2O.O
15.18.2.6 Diameter, 11/4" No. 1 Plumber 16.O
15.18.2.7 Diameter, 11/2" No. 1 Plumber 13.O

15.18.3 One side threaded one side flanged


15.18.3.1 Diameter, 1/2" No. 1 Plumber 9.5
15.18.3.2 Diameter, 3/4" No. 1 Plumber 7.9
15.18.3.3 Diameter, 1" No. 1 Plumber 7.5
15.18.3.4 Diameter, 11/4" No. 1 Plumber 6.O
15.18.3.5 Diameter, 11/2" No. 1 Plumber 5.2
15.18.3.6 Diameter, 2" No. 1 Plumber 4.4

15.18.4 Both sides flanged


15.18.4.1 Diameter, 2" No. SI - 1 2.6
15.18.4.2 Diameter, 3" No. SI - 1 2.3
15.18.4.3 Diameter, 4" No. SI - 1 1.6
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
15.18.4.4 Diameter, 5" No. SI - 1 1.6
15.18.4.5 Diameter, 6" No. SI - 2 1.6
15.18.4.6 Diameter, 8" No. SI - 2 1.O
15.18.4.7 Diameter, 10" No. SI - 2 O.5
15.18.4.8 Diameter, 12" No. SI - 2 O.3

Bell & spigot (with oakum & leaded joint for metal
15.18.5 pipes)
15.18.5.1 Diameter, 2" No. SI - 1 2.6
15.18.5.2 Diameter, 3" No. SI - 1 2.6
15.18.5.3 Diameter, 4" No. SI - 1 1.6
15.18.5.4 Diameter, 5" No. SI - 2 2.1
15.18.5.5 Diameter, 6" No. SI - 2 2.1
15.18.5.6 Diameter, 8" No. SI - 4 1.6
15.18.5.7 Diameter, 10" No. SI - 4 1.6
15.18.5.8 Diameter, 12" No. SI - 4 1.O

15.18.6 Tee & fitings


15.8.6.1 All side threaded
15.18.6.1.1 Diameter, 1/4" No. 1 Plumber 2O.O
15.18.6.1.2 Diameter, 3/8" No. 1 Plumber 18.O
15.18.6.1.3 Diameter, 1/2" No. 1 Plumber 16.O
15.18.6.1.4 Diameter, 3/4" No. 1 Plumber 15.5
15.18.6.1.5 Diameter, 1" No. 1 Plumber 13.5
15.18.6.1.6 Diameter, 11/4" No. 1 Plumber 11.O
15.18.6.1.7 Diameter, 11/2" No. 1 Plumber 8.9
15.18.6.1.8 Diameter, 2" No. 1 Plumber 6.9
15.18.6.2 All sides flanged
15.18.6.2.1 Diameter, 2" No. SI - 1 14.O
15.18.6.2.2 Diameter, 3" No. SI - 1 11.O
15.18.6.2.3 Diameter, 4" No. SI - 1 6.9
15.18.6.2.4 Diameter, 5" No. SI - 1 5.2
15.18.6.2.5 Diameter, 6" No. SI - 2 6.9
15.18.6.2.6 Diameter, 8" No. SI - 2 5.O
15.18.6.2.7 Diameter, 10" No. SI - 2 4.O
15.18.6.2.8 Diameter, 12" No. SI - 2 3.O

15.19 Cuting & threading


15.19.1 Diameter, 1/4" No. 1 Plumber 32.O
15.19.2 Diameter, 3/8" No. 1 Plumber 32.O
15.19.3 Diameter, 1/2" No. 1 Plumber 32.O
15.19.4 Diameter, 3/4" No. 1 Plumber 32.O
15.19.5 Diameter, 1" No. 1 Plumber 28.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
15.19.6 Diameter, 11/4" No. 1 Plumber 26.O
15.19.7 Diameter, 11/2" No. 1 Plumber 24.O
15.19.8 Diameter, 2" No. 1 Plumber 26.O
15.19.9 Diameter, 3" No. 1 Plumber 12.O

15.2O Hydrants (encased, wall type)


15.20.1 Diameter, 3/4" cast iron connection No. 1 Plumber 8.O
15.20.2 Diameter, 1" cast iron connection No. 1 Plumber 7.O
STANDARD STANDARD OUT
ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

16 Electrical Installation

16.1 Raceways

16.1.1 Galvanized tray 4" deep 4"rung spacing


16.1.1.1 6" wide m 1 Electrican 7.6
16.1.1.2 12" wide m 1 Electrican 6.6
16.1.1.3 18" wide m 1 Electrican 6.3
16.1.1.4 24" wide m 1 Electrican 6.1

16.1.2 Aluminum tray 4"deep 6"rung spacing


16.1.2.1 6" wide m 1 Electrican 14.O
16.1.2.2 12" wide m 1 Electrican 13.5
16.1.2.3 18" wide m 1 Electrican 12.O
16.1.2.4 24" wide m 1 Electrican 11.O

Conduits to 5m high including all terminations


16.1.3 fittings supports and scoffoldings
16.1.3.1 Rigid galvanized steel m 1 Electrican 15.5
16.1.3.1.1 1/2" m 1 Electrican 15.5
16.1.3.1.2 3/4" m 1 Electrican 14.O
16.1.3.1.3 1" m 1 Electrican 12.5
16.1.3.1.4 11/4" m 1 Electrican 11.O
16.1.3.1.5 11/2" m 1 Electrican 1O.5
16.1.3.1.6 2" m 1 Electrican 9.5
16.1.3.1.7 21/2" m 1 Electrican 7.9
16.1.3.2 Electric metallic tubing m 1Electrican 26.5
16.1.3.2.1 1/2"
16.1.3.2.2 3/4" m 1 Electrican 2O.5
16.1.3.2.3 1" m 1 Electrican 18.O
16.1.3.2.4 11/4" m 1 Electrican 15.5
16.1.3.2.5 11/2" m 1 Electrican 14.O
16.1.3.2.6 2" m 1 Electrican 12.5

Conduits in concrete slab including terminations


16.1.4 and supports.
16.1.4.1 PVC conduits m 1 Electrican 58.O
16.1.4.1.1 1/2" m 1 Electrican 58.O
16.1.4.1.2 3/4" m 1 Electrican 49.5
16.1.4.1.3 1" m 1 Electrican 43.O
16.1.4.1.4 11/4" m 1 Electrican 36.5
16.1.4.1.5 11/2" m 1 Electrican 3O.O
16.1.4.1.6 2" m 1 Electrican 26.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
16.1.4.2 Rigid galvanized steel m 1 Electrican 43.O
16.1.4.2.1 1/2" m 1 Electrican 43.O
16.1.4.2.2 3/4" m 1 Electrican 36.5
16.1.4.2.3 1" m 1 Electrican 28.O
16.1.4.2.4 11/4" m 1 Electrican 23.5
16.1.4.2.5 11/2" m 1 Electrican 21.5
16.1.4.2.6 2" m 1 Electrican 19.5

16.2 Conductors and grounding

16.2.1 Wire
16.2.1.1 600 V type THW copper solid
16.2.1.1.1 # 14 (2.5mm2) m 1 Electrican 275.O
16.2.1.1.2 # 12 (4mm2) m 1 Electrican 235.O
16.2.1.1.3 # 10 (6mm2) m 1 Electrican 21O.O
16.2.1.2 600 V type THW copper stranded
16.2.1.2.1 # 14 (2.5mm2) m 1 Electrican 275.O
16.2.1.2.2 # 12 (4mm2) m 1 Electrican 235.O
16.2.1.2.3 # 10 (4mm2) m 1 Electrican 21O.O
16.2.1.2.4 # 8 (10mm2) m 1 Electrican 17O.O
16.2.1.2.5 # 6 (16mm2) m 1 Electrican 135.O
16.2.1.2.6 # 4 (25mm2) m 1 Electrican 11O.O
16.2.1.2.7 # 3 (35mm2) m 1 Electrican 1O5.O
16.2.1.2.8 # 1/0 (50mm2) m 1 Electrican 7O.O
16.2.1.2.9 # 2/0 (70mm2) m 1 Electrican 61.O
16.2.1.2.10 # 250mcm (120mm2) m 1 Electrican 42.O
16.2.1.2.11 # 500mcm (240mm2) m 1 Electrican 34.O

16.2.2 Armoured cable


16.2.2.1 600V copper 14, 2 wires (2 x 2.5mm2) m 1 Electrican 5O.O
16.2.2.2 600V copper 14, 3 wires (3 x 2.5mm2) m 1 Electrican 46.O
16.2.2.3 600V copper 12, 2 wires (2 x 4mm2) m 1 Electrican 48.O
16.2.2.4 600V copper 14, 2 wires (2 x 2.5mm2) m 1 Electrican 42.O
16.2.2.5 600V copper 14, 2 wires (2 x 2.5mm2) m 1 Electrican 27.O
16.2.2.6 Conductor with PVC cover in cable tray
16.2.2.6.1 # 6,3 (3 x 16mm2) m 1 Electrican 84.O
16.2.2.6.2 # 4,3 (3 x 25mm2) m 1 Electrican 73.O
16.2.2.6.3 # 1/10,3 (3 x 50mm2) m 1 Electrican 48.5
16.2.2.6.4 # 2/0,3 (3 x 70mm2) m 1 Electrican 46.O
16.2.2.6.5 # 250mcm,3 (3 x 120mm2) m 1 Electrican 32.5
16.2.2.6.6 # 500mcm,3 (3 x 240mm2) m 1 Electrican 27.O
16.2.3 Control Cable
600V, copper, Thwn, wire # 14 with PVC jacket

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
16.2.3.1 2 wires (2 x 2.5 mm2) m 1 Electrican 26O
16.2.3.2 4 wires (4 x 2.5 mm2) m 1 Electrican 2OO
16.2.3.3 6 wires (6 x 2.5 mm2) m 1 Electrican 17.OO
16.2.3.4 8 wires (8 x 2.5 mm2) m 1 Electrican 15O.O
16.2.3.5 10 wires (10 x 2.5 mm2) m 1 Electrican 14O.O
16.2.3.6 12 wires (12 x 2.5 mm2) m 1 Electrican 125.O
16.2.3.7 14 wires (14 x 2.5 mm2) m 1 Electrican 11O.O
16.2.3.8 16 wires (16 x 2.5 mm2) m 1 Electrican 1OO.O
16.2.3.9 18 wires (18 x 2.5 mm2) m 1 Electrican 95.O
16.2.3.10 20 wires (20 x 2.5 mm2) m 1 Electrican 86.O
16.2.3.11 22 wires (22 x 2.5 mm2) m 1 Electrican 8O.O

16.2.4 Ground rods


16.2.4.1 Rod, copper clad, 3/4"diameter 2.5m long No 1 Electrican 3.8
16.2.4.2 Rod, copper clad, 3/4"diameter 3.0m long No 1 Electrican 3.1
16.2.4.3 Rod, copper clad, 3/4"diameter 5.0m long No 1 Electrican 2.6
16.2.4.4 Bare copper # 6 (16mm2) m 1 Electrican 22O.O

16.3 Boxes and Writing Devices

16.3.1 Pull box & cabinets


16.3.1.1 Flush mounted
16.3.1.1.1 6"L X 6"W X 6"D No 1 Electrican 6.1
16.3.1.1.2 8"L X 6"W X 6"D No 1 Electrican 4.9
16.3.1.1.3 10"L X 6"W X 6"D No 1 Electrican 4.3
16.3.1.1.4 12"L X 12"W X 6"D No 1 Electrican 3.1
16.3.1.1.5 16"L X 16"W X 6"D No 1 Electrican 2.8
16.3.1.1.6 20"L X 20"W X 6"D No 1 Electrican 2.4
16.3.1.1.7 24"L X 18"W X 8"D No 1 Electrican 1.8
16.3.1.1.8 24"L X 24"W X 10"D No 1 Electrican 1.5
16.3.1.1.9 30"L X 24"W X 12"D No 1 Electrican 1.2
16.3.1.1.10 36"L X 36"W X 12"D No 1 Electrican 0.9

16.3.1.2 Surface mounted


16.3.1.2.1 6"L X 6"W X 6"D No 1 Electrican 3.O
16.3.1.2.2 8"L X 6"W X 6"D No 1 Electrican 3.2
16.3.1.2.3 10"L X 6"W X 6"D No 1 Electrican 2.5
16.3.1.2.4 12"L X 12"W X 6"D No 1 Electrican 2.O
16.3.1.2.5 16"L X 16"W X 6"D No 1 Electrican 1.3
16.3.1.2.6 20"L X 20"W X 6"D No 1 Electrican O.8
16.3.1.2.7 24"L X 18"W X 8"D No 1 Electrican O.7
16.3.1.2.8 24"L X 24"W X 10"D No 1 Electrican O.5
16.3.1.2.9 30"L X 24"W X 12"D No 1 Electrican O.4
16.3.1.2.10 36"L X 36"W X 12"D No 1 Electrican O.2

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

16.3.2 Wiring devices


16.3.2.1 Toggle switch single pole 15 A No 1 Electrican 38.O
16.3.2.2 Toggle switch 3 way 15 A No 1 Electrican 22.O
16.3.2.3 Toggle switch 4 way 15 A No 1 Electrican 14.5
16.3.2.4 Dimmer switch single pole No 1 Electrican 15.O
16.3.2.5 Receptacle, duplex, grounded, 15A No 1 Electrican 38.O
16.3.2.6 Receptacle, duplex, grounded, 20A No 1 Electrican 25.5
16.3.2.7 Dryer, 30A No 1 Electrican 15.5
16.3.2.8 Range, 50A No 1 Electrican 11.5
16.3.2.9 Wall plates, stainless 1 gang No 1 Electrican 82.5
16.3.2.10 Wall plates, stainless 2 gang No 1 Electrican 54.5
16.3.2.11 Lampholder No 1 Electrican 27.O
16.3.2.12 Pullchain with receptacle No 1 Electrican 22.5

16.3.3 Low Voltage switching


16.3.3.1 Standard, relays No 1 Electrican 11.O
16.3.3.2 Standard flush switch No 1 Electrican 36.O
16.3.3.3 Standard surface switch No 1 Electrican 36.O
16.3.3.4 Switch plates 1 gang (plastic / stainless steel)
16.3.3.4.1 1 switch No 1 Electrican 8O.O
16.3.3.4.2 2 switch No 1 Electrican 8O.O
16.3.3.4.3 3 switch No 1 Electrican 8O.O
16.3.3.5 Switch plates 2 gang (plastic / stainless steel)
16.3.3.5.1 3 switch No 1 Electrican 5O.O
16.3.3.5.2 4 switch No 1 Electrican 5O.O
16.3.3.6 Switch plates 3 gang (stainless steel)
16.3.3.6.1 9 switch No 1 Electrican 3O.O

16.4 Starters, boards & switches

16.4.1 Circuit breakers


16.4.1.1 Enclosed, NEMA 1 600v, 3 pole 30A No 1 Electrican 1.6
16.4.1.2 Enclosed, NEMA 1 600v, 3 pole 60A No 1 Electrican 1.4
16.4.1.3 Enclosed, NEMA 1 600v, 3 pole 100A No 1 Electrican 1.2
16.4.1.4 Enclosed, NEMA 1 600v, 3 pole 225A No 1 Electrican O.8
16.4.1.5 Enclosed, NEMA 1 600v, 3 pole 400A No 1 Electrican O.4
16.4.1.6 Enclosed, NEMA 1 600v, 3 pole 600A No 1 Electrican O.3
16.4.1.7 Enclosed, NEMA 1 600v, 3 pole 800A No 1 Electrican O.2

16.4.2 Motor Connections

16.4.2.1 Flexible conduit & fittings 240v 1HP motor No 1 Electrican 4.6
16.4.2.2 Flexible conduit & fittings 240v 25HP motor No 1 Electrican 2.0
16.4.2.3 Flexible conduit & fittings 240v 50HP motor No 1 Electrican 1.7
16.4.2.4 Flexible conduit & fittings 240v 100HP motor No 1 Electrican 1.1

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
16.4.2.4 Motor starters and controls 480v No 1 Electrican 1.1
16.4.2.4.1 5 HP, size 0 No 1 Electrican 1.6
16.4.2.4.2 10HP, size I No 1 Electrican 1.1
16.4.2.4.3 25 HP, sizeII No 1 Electrican O.8
16.4.2.4.4 50 HP, size III No 1 Electrican O.6
16.4.2.4.5 100HP, size IV No 1 Electrican O.4
16.4.2.4.6 200 HP, size V No 1 Electrican O.3
16.4.2.5 Motor starters and controls 480v
Combination with motor circuit protectors
16.4.2.5.1 5 HP, size 0 No 1 Electrican 1.8
16.4.2.5.2 10HP, size I No 1 Electrican 1.3
16.4.2.5.3 25 HP, sizeII No 1 Electrican 1.O
16.4.2.5.4 50 HP, size III No 1 Electrican O.7
16.4.2.5.5 100HP, size IV No 1 Electrican O.4

16.4.3 Panel boards


NOQB, 20A 1 pole bolt on circuit breakers
3 wire, 120/240 V, 100A main lug
16.4.3.1 10 Circuits No 1 Electrican 1.O
16.4.3.2 14 Circuits No 1 Electrican O.9
16.4.3.3 18 Circuits No 1 Electrican O.7
16.4.3.4 20 Circuits No 1 Electrican O.6
16.4.3.5 4, wire, 220/480V, 100A main lug
16.4.3.5.1 12 Circuits No 1 Electrican O.9
16.4.3.5.2 20 Circuits No 1 Electrican O.6
16.4.3.6 4, wire, 220/480V, 225A main lug
16.4.3.6.1 24 Circuits No 1 Electrican O.4
16.4.3.6.2 30 Circuits No 1 Electrican O.4
16.4.3.6.3 36 Circuits No 1 Electrican O.4
16.4.3.7 4, wire, 220/480V, 400A main lug
16.4.3.7.1 30 Circuits No 1 Electrican O.3
16.4.3.7.2 42 Circuits No 1 Electrican O.2

16.4.4 Panel board circuit breaker


10000A 1.C.240V, 1 Pole bolt on
16.4.4.1 15 to 50A No 1 Electrican 1O.O
16.4.4.2 60A No 1 Electrican 8.O
16.4.4.3 80 to 100A No 1 Electrican 8.O

16.5 Lighting
Interior lighting Fixtures including 1As,
mounting hardware and connection

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
16.5.1 Florcent, CW 1As 1As recess mounted
16.5.1.1 1'W X 4'L two 40W No 1 Electrican 5.7
16.5.1.2 2W X 4'L two 40W No 1 Electrican 5.3
16.5.1.3 2'W X 4'L three 40W No 1 Electrican 5.o
16.5.1.4 2'W X 4'L four 40W No 1 Electrican 4.7
16.5.1.5 4'W X 4'L four 40W No 1 Electrican 3.2
16.5.1.6 4'W X 4'L six 40W No 1 Electrican 3.1
16.5.1.7 4'W X 4'L eight 40W No 1 Electrican 2.9

16.5.2 Florecent, CW 1As 1As surface mounted


16.5.2.1 1'W X 4'L two 40W No 1 Electrican 7.O
16.5.2.2 2W X 4'L two 40W No 1 Electrican 6.2
16.5.2.3 2'W X 4'L three 40W No 1 Electrican 5.7
16.5.2.4 2'W X 4'L four 40W No 1 Electrican 5.3
16.5.2.5 4'W X 4'L four 40W No 1 Electrican 3.6
16.5.2.6 4'W X 4'L six 40W No 1 Electrican 3.3
16.5.2.7 4'W X 4'L eight 40W No 1 Electrican 3.1
16.5.2.8 2'W X 8'L four 40W No 1 Electrican 3.2
16.5.2.9 2'W X 8'L eight 40W No 1 Electrican 3.1

16.5.3 Strip fixture


16.5.3.1 4'L one 40W R.S. No 1 Electrican 7.2
16.5.3.2 4'L one 40W S.L. No 1 Electrican 6.7
16.5.3.3 4'L two 40W R.S. No 1 Electrican 6.7
16.5.3.4 4'L two 40W S.L. No 1 Electrican 5.9

16.5.4 Pendent mounted, industerial, white porcelain


enamel
16.5.4.1 4'L two 40W R.S. No 1 Electrican 4.8
16.5.4.2 4'L two 60W H.O. No 1 Electrican 4.2

16.5.5 High bay, aluminum reflector


16.5.5.1 Single unit 400W DX1A No 1 Electrican 1.9
16.5.5.2 Single unit 1000W DX1A No 1 Electrican 1.6
16.5.6 Incadescent, ceiling, recess mtd., round alzak
reflector, prewired
16.5.6.1 100 watt No 1 Electrican 7.1
16.5.6.2 150 watt No 1 Electrican 7.1
16.5.6.3 300 watt No 1 Electrican 5.9

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
16.5.6.4 Square glass lens with metal trim prewired
16.5.6.4.1 100 watt No 1 Electrican 5.9
16.5.6.4.2 150 watt No 1 Electrican 5.9
16.5.4.3 300 watt No 1 Electrican 5.O

16.5.7 Vapour tight, ceiling mounted


16.5.7.1 Fluorecent RS, 4'long ceiling munted two 40W No 1 Electrican 2.2
16.5.7.2 Mercury vapor with balast, 175W No 1 Electrican 2.2
16.5.7.3 Incadesecent, ceiling mounted, 200W No 1 Electrican 3.2

16.7 Exterior fixtures with 1As

16.7.1 Wall mounted


16.7.1.1 Wall mounted incandescent 100W No 1 Electrican 7.8
16.7.1.2 Wall mounted quartz 100W No 1 Electrican 5.1
16.7.1.3 Wall mounted mercury vapor 40W No 1 Electrican 5.1
16.7.1.4 Wall mounted low pressure sodium 55W No 1 Electrican 3.9

16.7.2 Flood light with balast and 1A pole mounted


pole not included
16.7.2.1 Mercury vapour 400W No 1 Electrican 2.O
16.7.2.2 Metal halide 400W No 1 Electrican 2.O
16.7.2.3 High pressure sodium 400W No 1 Electrican 2.O

16.7.3 Road area luminaire


16.7.3.1 Mercury vapour 400W No 1 Electrican 2.O
16.7.3.2 Metal halide 400W No 1 Electrican 2.O
16.7.3.3 High pressure sodium 400W No 1 Electrican 2.O

16.8 Light pole anchor base

16.8.1 Steel pole Galvanized


16.8.1.1 6000mm high No R-3 2.1
16.8.1.2 9000mm high No R-3 1.9

16.8.2 Bracket arm


16.8.2.1 Bracket arm 1 arm No 1 Electrican 6.O
16.8.2.2 Bracket arm 2 arm No 1 Electrican 6.O
16.8.2.3 Bracket arm 3 arm No 1 Electrican 4.O
16.8.2.4 Bracket arm 4 arm No 1 Electrican 4.O

16.9 Lamps

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

16.9.1 Incandencent light No 1 Electrican 2OO.O


16.9.2 Fluorescent rapid start cool white,
16.9.2.1 2' each 20W No 1 Electrican 79.O
16.9.2.2 4' each 40W No 1 Electrican 71.O
16.9.3 Mercury vapour mogul base delux white
16.9.3.1 100W No 1 Electrican 25.O
16.9.3.2 250W No 1 Electrican 25.O
16.9.3.3 400W No 1 Electrican 25.O
16.9.3.4 1000W No 1 Electrican 16.5

16.9.4 Metal halide mogul base


16.9.4.1 175W No 1 Electrican 25.O
16.9.4.2 400W No 1 Electrican 25.O
16.9.4.3 1000W No 1 Electrican 16.5

16.9.5 High pressure sodium


16.9.5.1 75W No 1 Electrican 25.O
16.9.5.2 250W No 1 Electrican 25.O
16.9.5.3 400W No 1 Electrican 25.O
16.9.5.4 1000W No 1 Electrican 16.5

16.1O Special systems


16.10.1 Clock and clock syste,
16.10.1.1 Master controller No 1 Electrican O.2
16.10.1.2 Clock 12" diameter single face No 1 Electrican 5.O
16.10.1.3 Clock 12" diameter double face No 1 Electrican 3.9

16.10.2 Door bell system including transformer & button


16.10.2.1 6" bell No 1 Electrican 4.O
16.10.2.2 Buzzer No 1 Electrican 4.O

16.10.3 Sound system


16.10.3.1 Outlet projector No 1 Electrican 7.4
16.10.3.2 Microphone No 1 Electrican 3.7
16.10.3.3 Speakers, ceiling or wall No 1 Electrican 7.4
16.10.3.4 Alifier 250W No 1 Electrican O.9
16.10.3.5 Intercom 25 station capacity master station No 1 Electrican O.9
16.10.3.6 Intercome outlet No 1 Electrican 7.4
16.10.3.7 Emergency call system 12 zone announcment No 1 Electrican 1.2
16.10.3.8 Bell No 1 Electrican 4.9

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

16.10.4 Wiring residential 6000mm average run


Using non-metalic sheated cables
16.10.4.1 Air conditioning receptacle No 1 Electrican 6.7
16.10.4.2 Duplex receptacle No 1 Electrican 8.7
16.10.4.3 Intercom - 8 stations No 1 Electrican O.5
16.10.4.4 Light fixtures average No 1 Electrican 1O.5
16.10.4.5 light wiring No 1 Electrican 1O.5
16.10.4.6 switch single pole No 1 Electrican 1O.5
16.10.4.7 switch 3 - way No 1 Electrican 8.1
16.10.4.8 water heater circuit No 1 Electrican 3.5

16.11 Electrical Installation (General)

16.11.1 Distribution boards


16.11.1.1 Rating less than 50A No ELI - 4 1.O
16.11.1.2 Rating between 50A - 80A No ELI - 4 O.5
16.11.1.3 Rating between 100A - 250A No ELI - 1 O.3
16.11.1.4 Rating between 300A - 500A No ELI - 3 O.3
16.11.1.5 Rating greater than 500A No ELI - 2 O.2

16.11.2 Light points


16.11.2.1 Light points No ELI - 1 4.O
16.11.2.2 Socket No ELI - 1 4.O
16.11.2.3 Bell No ELI - 1 4.O
16.11.2.4 Fan No ELI - 1 4.O
16.11.2.5 Speaker No ELI - 1 4.O
16.11.3 Accessories
16.11.3.1 Telephone No ELI - 1 6.7
16.11.3.2 Intercome No ELI - 1 6.7
16.11.3.3 T.V. Points No ELI - 1 6.7

16.11.4 Light fittings


16.11.4.1 Fluoresent 4 X 20 No ELI - 5 8.O
16.11.4.2 Fluoresent 2 X 40, X40, 1X 20 No ELI - 5 1O.5
16.11.4.3 Globe No ELI - 5 16.O

16.11.5 Cables
16.11.5.1 Less than or equal to 4 X 16mm2 m ELI - 8 8.O
16.11.5.2 Between 3 X 25/16mm2 - 3 X 95/50mm2 m ELI - 7 8.O
16.11.5.3 Greater than or equal to 3 X 120/70mm2 m ELI - 6 8.O

16.11.6 Lightening Preventor No ELI - 9 O.3

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

17 External works and services


17.1 Prepare and roll subbase
17.1.1 For small areas m2 G-4 37O.O
17.1.2 For large areas m2 G-4 83O.O

17.2 Base course with crushed stone


17.2.1 75mm deep m2 EX - 46 223O.O
17.2.2 150mm deep m2 EX - 46 1675.O
17.2.3 200mm deep m2 EX - 46 1225.O
17.2.4 300mm deep m2 EX - 46 1OOO.O

17.3 Bituminuous paving


17.3.1 Wearing course
17.3.1.1 40mm thick m2 EX - 43 184O.O
17.3.1.2 75mm thick m2 EX - 43 92O.O

17.3.2 Base course


17.3.2.1 25mm thick m2 EX - 47 2565.O
17.3.2.2 50mm thick m2 EX - 47 128O.O
17.3.2.3 75mm thick m2 EX - 47 92O.O
17.3.2.4 100mm thick m2 EX - 47 665.O

17.3.3 Sand finish course


17.3.3.1 20mm thick m2 EX - 47 3175.O
17.3.3.2 25mm thick m2 EX - 47 2145.O

17.3.4 Gravel surface on asphalt


17.3.4.1 Screened and rolled m2 EX - 46 21OO.O
17.3.4.2 Screened and rolled with sealer and binder m2 EX - 46 1445.O

17.3.5 Patching utility trenches


17.3.5.1 50mm thick m2 EX - 47 215.O
17.3.5.2 75mm thick m2 EX - 47 145.O

17.4 Concrete paving with mesh without joint


or finish
17.4.1 150mm thick m2 EX - 49 1115.O
17.4.2 200mm thick m2 EX - 49 835.O
17.4.3 250mm thick m2 EX - 49 755.O

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
17.5 Curbs
17.5.1 Concrete berm
17.5.1.1 200mm wide X 150mm high m EX - 5O 6O.O
17.5.1.2 200mm wide X 200mm high m EX - 5O 6O.O

17.5.2 In situ concrete curbs


17.5.2.1 150mm x 500mm straignt m FW - 2 1OO.O
17.5.2.2 150mm x 500mm curved m FW - 2 9O.O

17.5.3 Formed curbs fixing


17.5.3.1 150mm x 500mm straight precast concrete m EX - 51 6O.O
17.5.3.2 150mm x 500mm curved precast concrete m EX - 51 52.O
17.5.3.3 125mm x 500mm straight granite m EX - 51 58.O
17.5.3.4 150mm x 500mm straight granite m EX - 51 58.O
17.5.3.5 125mm x 500mm curvedgranite m EX - 51 52.O
17.5.3.6 150mm x 500mm curved granite m EX - 51 52.O

17.5.4 Curb and gutter cast in place


17.5.4.1 150mm curb 150mm deep gutter & 600mm wide m FW - 2 76.O
17.5.4.2 150mm curb 150mm deep gutter & 750mm wide m FW - 2 69.O

17.6 Fill for embankment


17.6.1 From borrow, 1.6km haul compact and shape m3 EX - 52 24O.O

17.7 Fine grade


17.7.1 Small areas m2 G-3 445.O
17.7.2 Large areas m2 G-3 111O.O

Manholes including activities of excavation and


17.8 footing

17.8.1 Brick manhole


17.8.1.1 1200mm x 1200mm deep No BW - 1 O.7
17.8.1.2 1200mm x 1800mm deep No BW - 1 O.5
17.8.1.3 1200mm x 2500mm deep No BW - 1 O.4

17.8.2 Concrete pipe manhole of diameters


17.8.2.1 Diameter 600mm m EX - 55 6.5
17.8.2.2 Diameter 800mm m EX - 55 5.2
17.8.2.3 Diameter 1000mm m EX - 55 3.9
17.8.2.4 O 1200mm m EX - 55 3.2

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS

17.8.3.1 600mm x 600mm x 600mm deep No BW - 1 6.O


17.8.3.2 600mm x 600mm x 800mm deep No BW - 1 4.7
17.8.3.3 600mm x 600mm x 1000mm deep No BW - 1 3.3

17.8.3 H.C.B. manhole


17.8.3.4 800mm x 800mm x 600mm deep No BW - 1 4.7
17.8.3.5 800mm x 800mm x 800mm deep No BW - 1 3.3
17.8.3.6 800mm x 800mm x 1000mm deep No BW - 1 2.7

17.9 Trench hand trimming

17.1O Fill in trenches


17.10.1 Crushed bank run m3 EX - 53 13O.O
17.10.2 Screened 15mm to 20mm m3 EX - 53 13O.O

Pipe for drainage and sewage (extra. Not


17.11 included
17.11.1 Concrete pipe laying

17.11.1.1 150mm diameter m EX - 54 55.O


17.11.1.2 200mm diameter m EX - 55 62.O
17.11.1.3 250mm diameter m EX - 55 55.O
17.11.1.4 300mm diameter m EX - 55 41.O
17.11.1.5 400mm diameter m EX - 55 34.O
17.11.1.6 500mm diameter m EX - 55 24.O
17.11.1.7 600mm diameter m EX - 55 17.O

17.11.2 PVC pipe laying


17.11.2.1 150mm diameter m EX - 54 76.O
17.11.2.2 200mm diameter m EX - 54 66.O
17.11.2.3 250mm diameter m EX - 55 66.O
17.11.2.4 300mm diameter m EX - 55 62.O
17.11.2.5 400mm diameter m EX - 55 39.O

17.11.3 Galvanized steel pipe laying


17.11.3.1 100mm diameter m EX - 54 29.5
17.11.3.2 150mm diameter m EX - 54 26.5
17.11.3.3 200mm diameter m EX - 55 2O.O
17.11.3.4 250mm diameter m EX - 55 16.5
17.11.3.5 300mm diameter m EX - 55 13.O
17.11.3.6 350mm diameter m EX - 55 9.9
17.11.3.7 400mm diameter m EX - 55 9.2

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
17.11.3.8 450mm diameter m EX - 55 7.9
17.11.3.9 500mm diameter m EX - 55 7.2
17.11.3.10 600mm diameter m EX - 55 7.2

17.12 Gate valves (galvanized steel)


17.12.1 100mm diameter No EX - 54 3.6
17.12.2 150mm diameter No EX - 54 3.O
17.12.3 200mm diameter No EX - 54 2.4
17.12.4 250mm diameter No EX - 55 2.1
17.12.5 300mm diameter No EX - 55 1.8
17.12.6 350mm diameter No EX - 55 1.2
17.12.7 400mm diameter No EX - 55 1.2

17.13 Fencing

Monsonry fencing including activities of


17.13.1 excavation and concrete footing
17.13.1.1 Fence in 500mm thick stone m2 BW-1 3.0
17.13.1.2 Fence in 400mm thick stone m2 BW-1 3.0
17.13.1.3 Fence in 250mm thick brick m2 BW-1 3.0
17.13.1.4 Fence in 120mm thick brick m2 BW-1 5.0
17.13.1.5 Fence in 200mm thick hollow concrete block m2 BW-1 7.0
17.13.1.6 Fence in 150mm thick hollow concrete block m2 BW-1 6.0

17.13.2 Fence out of galvanized steel wire mesh


17.13.2.1 Height 1500mm m EX - 56 35.O
17.13.2.2 Height 2000mm m EX - 56 35.O

17.13.3 Fence out-of-plane wire mesh


17.13.3.1 Height 1500mm m EX - 56 35.O
17.13.3.2 Height 2000mm m EX - 56 35.O

17.13.4 Fencing of concrete posts


17.13.4.1 Fence out of three rows of barbed wire m EX - 56 37.O
17.13.4.2 Fence out of four rows of barbed wire m EX - 56 35.O
17.13.4.3 Fence out of five rows of barbed wire m EX - 56 3O.O
Fence out of four rows plus diagonally running
17.13.4.4 members crossing to form the shape "x" m EX - 56 35.O
Fence out of five rows plus diagonally running
17.13.4.5 members crossing to form the shape "x" m EX - 56 3O.O

17.13.5 Fencing of steel posts

STANDARD STANDARD OUT


ITEM No ACTIVITY DESCRIPTION UNIT CREW PUT NORMS
17.13.5.1 Fence out of three rows of barbed wire m EX - 56 37.O
17.13.5.2 Fence out of four rows of barbed wire m EX - 56 35.O
17.13.5.3 Fence out of five rows of barbed wire m EX - 56 3O.O
17.13.5.4 Fence out of four rows + an "x" of barbed wire m EX - 56 35.O
17.13.5.5 Fence out of five rows + an "x" of barbed wire m EX - 56 3O.O
17.4 Gate

17.14.1 Gate posts


17.14.1.1 Concrete posts
17.14.1.1.1 200mm x 200mm, 2200m high No EX - 56 2O.O
17.14.1.1.2 250mm x 250mm, 2200m high No EX - 56 19.O
17.14.1.1.3 300mm x 300mm, 2200m high No EX - 56 18.O
17.14.1.1.4 400mm x 400mm, 2200m high No EX - 56 17.O
17.14.1.1.5 600mm x 600mm, 2200m high No EX - 56 15.O

17.14.1.2 Masonry posts


17.14.1.2.1 400mm x 400mm, 2200m high No BW - 1 3.O
17.14.1.2.2 600mm x 600mm, 2200m high No BW - 1 2.O
17.14.1.2.3 800mm x 800mm, 2200m high No BW - 1 2.O
17.14.1.2.4 1000mm x 1000mm, 2200m high No BW - 1 1.O
17.14.1.3 Steel posts
17.14.1.3.1 80mm x 80mm x 3mm 2200m high No EX - 56 2O.O
17.14.1.3.2 80mm x 80mm x 34mm 2200m high No EX - 56 18.O
17.14.1.3.3 100mm x 100mm x 3mm 2200m high No EX - 56 16.O
17.14.1.3.4 100mm x100mm x 4mm 2200m high No EX - 56 15.O

17.14.2 Gates

17.14.2.1 Steel sliding gates


17.14.2.1.1 2400mm x 2400mm No 2 Sswk 1.1
17.14.2.1.2 3000mm x 3000mm No 2 Sswk O.9
17.14.2.1.3 3500mm x 3500mm No 2 Sswk O.8
17.14.2.1.4 6000mm x 3000mm No 2 Sswk O.7

17.14.2.2 Hinged gate fixing to masonfy/ concrete posts


17.14.2.2.1 1200mm x 900mm No 2 Sswk 5.O
17.14.2.2.2 1500mm x 900mm No 2 Sswk 4.O
17.14.2.2.3 1800mm x 900mm No 2 Sswk 3.O
17.14.2.2.4 1800mm x 1200mm No 2 Sswk 3.O
17.14.2.2.5 2500mm x 2000mm No 2 Sswk 1.3
17.14.2.2.6 3000mm x 2000mm No 2 Sswk O.7
17.14.2.2.7 3500mm x 2000mm No 2 Sswk O.7
17.14.2.2.8 3000mm x 3000mm No 2 Sswk O.6
17.14.2.2.9 3500mm x 3500mm No 2 Sswk O.4
17.14.2.2.10 6000mm x 3000mm No 2 Sswk O.3
STANDARD CREW
Excavation & Earthwork UNIT CAPACITY UNIT CAPACITY

EX - A1
1 Equipment Operator III
1 Grease boy 1 Hydraulic Excavator C.Y 1 m3 0.765

EX - A2
1 Equipment Operator III
1 Grease boy 1 Hydraulic Excavator C.Y 1.5 m3 1.15

EX - A3
1 Equipment Operator III
1 Grease boy 1 Hydraulic Excavator C.Y 2 m3 1.53

EX - A4
1 Equipment Operator III
1 Grease boy 1 Hydraulic Excavator C.Y 3.5 m3 2.7

EX - A5
1 Equipment Operator III
1 Grease boy 1 Hydraulic Excavator C.Y ½ m3 0.38

EX - A6
1 Equipment Operator III
1 Grease boy 1 Hydraulic Excavator C.Y ¾ m3 0.57

EX - A7
1 Equipment Operator III 1 Crawler Crane ton. 15
1 Grease boy 1 Clamshell Bucket C.Y 5 m3 3.8

EX - A8
1 Equipment Operator III 1 Crawler Crane ton. 25
1 Grease boy 1 Clamshell Bucket C.Y 1 m3 0.765

EX - A9
1 Equipment Operator II
½ Labouer II
1 Dozer H.P 75

EX - A9A
1 Equipment Operator II
½ Labouer II
1 Dozer H.P 140

EX - A9B
1 Equipment Operator II
½ Labouer II
1 Dozer H.P 200
STANDARD CREWS UNIT CAPACITY UNIT CAPACITY

EX - A10
1 Equipment Operator II
½ Labouer II
1 Dozer H.P 300
EX - A11
1 Equipment Operator III
1 Grease boy 1 Crawler Crane ton. 20
1 Bucket H.P 0.75 m3 0.57

EX - A12
1 Equipment Operator III
1 Grease boy 1 Crawler Crane ton. 40
1 Bucket H.P 1.5 m3 1.15

EX - A13
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 2.25 m3 1.15

EX - A15
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 2.25 m3 1.72

EX - A16
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 3.5 m3 2.7

EX - A17
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 5 m3 3.8

EX - A18
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 1 m3 0.765

EX - A19
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 1.5 m3 1.15
STANDARD CREWS UNIT CAPACITY UNIT CAPACITY

EX - A20
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 2.5 m3 1.9

EX - A21
1 Equipment Operator II
½ Labouer II 1 Front end Loader,
Track Nounted H.P 5.5 m3 4.2

EX - A22
1 Equipment Operator III
1 Grease boy 1 Gradall ton. 3
H.P 5 m3 3.8

EX - A23
1 Equipment Operator III
1 Grease boy 1 Gradall
H.P 1 m3 0.77

EX - A25
1 Equipment Operator III
½ Labouer II
1/4 Equipment Operator III
1 Scraper towed C.Y. 12 m3 9.18
1 Dozer H.P 300
1/4 Dozer H.P 300

EX - A26
1 Equipment Operator II
½ Labouer II 1 Scraper towed C.Y. 15 m3 11.48
1/4 Dozer H.P 300

EX - A27
1 Equipment Operator III
½ Labouer II
1/4 Equipment Operator III
1 Self propelled
Scraper C.Y. 14 m3 10.71
1/4 Dozer H.P 300
STANDARD CREWS UNIT CAPACITY UNIT CAPACITY

EX - A28
1 Equipment Operator III
½ Labouer II
1/4 Equipment Operator III
1 Self propelled
Scraper C.Y. 14 m3 18.36
1/4 Dozer H.P 300

EX - A29
1 Equipment Operator III
½ Labouer II
1/4 Equipment Operator III

1 Elevated Scraper C.Y. 11 m3 8.42


1/4 Dozer H.P 300

EX - A30
1 Equipment Operator III
½ Labouer II
1/4 Equipment Operator III

1 Elevated Scraper C.Y. 20 m3 15.3


1/4 Dozer H.P 300

EX - A31
1 Equipment Operator III
1 Grease boy
1 Power Shovel
1 Front End Attachment C.Y. 0.5 m3 0.38

EX - A32
1 Equipment Operator III
1 Grease boy
1 Power Shovel m3 0.57
1 Front End Attachment C.Y. 0.75 m3 0.57

EX - A33
1 Equipment Operator III
1 Grease boy
1 Power Shovel
1 Front End Attachment C.Y. 1 m3 0.77
STANDARD CREWS UNIT CAPACITY UNIT CAPACITY

EX - A34
1 Equipment Operator III
1 Grease boy
1 Power Shovel
1 Front End Attachment 1½ m3 1.15

EX - A35
1 Equipment Operator III
1 Grease boy
1 Backhoe C.Y. m3 0.29

EX - A36
1 Equipment Operator III
1 Grease boy
1 Backhoe C.Y. 0.5 m3 0.38

EX - A37
1 Equipment Operator III
1 Grease boy
1 Hydraulic Excavator C.Y. m3 0.48

EX - A38
1 Equipment Operator III
1 Grease boy
1 Hydraulic Excavator C.Y. 1 1/4 m3 0.96

EX - A39
1 Equipment Operator III
1 Grease boy
1 Hydraulic Excavator C.Y. 2½ m3 1.9

EX - A40
1 Equipment Operator III
1 Chain Trencher H.P. 12

EX - A41
1 Equipment Operator II
1 Chain Trencher H.P. 40

EX - A42
½ Gang Chief
2 Labourers II

EX - A43
1/4 Gang Chief
3 Labourers II Sledge Hammer Pcs 1 Pcs 1

STANDARD CREWS UNIT CAPACITY UNIT CAPACITY

EX - A44
1 Equipment Operator III
1 Equipment Operator III
1 Dozer H.P. 300
1 Excavator m3 3.5
EX - A45
1 Blasting forman
1Driller
1Equipment operator
1 Crawller type drill 4"
1 Air Compressor hose

EX - A46
1 Forman
1Helper
1Equipment operator
1 Dozer H.P 300
1Agg. Spreader

EX - A47
1 Forman
1Helper
1Equipment operator
1 Paving machine
1Roller ton 1O

EX - A48
1 Forman
1Helper
1Equipment operator
1Roller ton 3

EX - A49
1 Forman
1Helper
2 Equipment operator
1 Bar bender
Plasterer
1 Grader H.P 200
1 Paving machine

STANDARD CREWS UNIT CAPACITY UNIT CAPACITY

EX - A50
1 Forman
1Helper
1Equipment operator
1 Berm machine

EX - A51
1 Forman
1Helper
1Equipment operator
1 Oiler
1 machine ton 3

EX - A52
1Equipment operator
1 Helper
2 Truck driver
2 Truck m3 12
1Dozer H.P 200

EX - A53
1Equipment operator
1 Helper
1Backhoe loader H.P 75

EX - A54
1 Forman
1 plumber
1 Helper

EX - A55
1 Forman
1 plumber
1 Equipment Operator
1 Helper 1 Self-propelled crane ton 5

EX - A56
1 Forman
2 Helper

EX - A57
1 Forman
1 Equipment Operator
1 Helper
1 Oiler
1 Crane ton 20

STANDARD CREWS UNIT CAPACITY UNIT CAPACITY

FILL

F - B1
1 Labourer II
1 Gas Engine power Tool

F - B2
1 Equipment Operator III
½ Labourer II
1 Dozer H.P 200

F - B3
1 Foreman (outside)
4 Laboureres II
1 Equipment Operator II
Earthwork Equipment

F - B4
1 Equipment Operator III
Labourer
1 Sheepfoot roller H.P 130

F - B5
1 Equipment Operator III
1 Labourer
1 Roller Compactor ton 10

F - B6
1 Foreman
4 Labourer
Air compressor cfm 250
Air tools & Accessories

F - B7
1 Equipment Operator III
1Labourer
1 Dozer H.P 200
Air compressor cfm 250
Air tools & Accessories

F - B5
1 Equipment Operator III
1 Labourer 1 Dozer H.P 200
1 Towed vibratory roller

STANDARD CREW UNIT CAPACITY UNIT CAPACITY

Grading

G - C1
1 Equipment Operator III
½ Laboureer II
1 Scaper, towed C.Y 7 m3 5.36
1/4 Dozer H.P 300

G - C2
1 Equipment Operator III
1 Laboureer II
1 Dozer H.P 200

G - C3
1 Equipment Operator III
1 Laboureer II
1 Grader Ib 30,000 ton 13.6

G - C4
2 Equipment Operator II
1 Self propelled Grader 1 Self Prolled Grader
1 Roller ton 10

G - C5
1 Equipment Operator III
1 Labourer 1 Self Prolled Grader H.P 150

G - C6
1 Equipment Operator III
1 Labourer 1 Self Prolled Grader H.P 200

G - C7
1 Equipment Operator III
2 Labourer 1 Self Prolled Grader H.P 300

Disposal

D - D1
1 Truck Driver IV
1 Dump Truck C.Y 6 m3 4.59

D - D2
Drive IV
1 Truck 1 Dump Truck C.Y 12 m3 9.18

STANDARD CREW UNIT CAPACITY UNIT CAPACITY

D - D3
1 Truck Driver IV
1 Truck Tractor ton 40
1 Dump Trailer C.Y 16.5 m3 12.62

D - D4
1 Truck Driver IV
1 Truck Tractor ton 40
1 Dump Trailer C.Y 20 m3 15.3

D - D5
1 Equipment Operator II
½ Labourer II
1 Dozer H.P 200

Hard Core

1 Mason II HC - E1
4 Labouers II

HC - E2
1 Mason II
4 Labourers II

Concrete

C - F1
1 Labourer Forman
5 Labourers II
1 Plasterer II
1 Equipment Operator II
2 Gas engine vibrator
1 Pump 4" Diameter
(102mm) F 80 m 24.4

C - F2
1 Labourer Forman
5 Labourers II
1 Plasterer II
1 Equipment Operator II
2 Gas engine vibrator
1 Concrete Bucket C.Y. 1 m3 0.765
1 Crane or Pump

C - F3
1 Forman
5 Labourers II
1 Plasterer
2 Gas engine vibrator

STANDARD CREW UNIT CAPACITY UNIT CAPACITY

C - F4
2 Forman
8 Skilled Workers
1/8 Crane & tools ton 80

C - F5
1/8 Labouer Forman
1 Labourer II
1 Concrete Cart C.F. 10 m3 7.65

C - F6
1/8 Labouer Forman
1 Labourer II
1 Concrete Cart C.F. 18 m3 0.51

C - F7
2 Forman
8 Skilled workers
1/4 Crane, & Tools ton 80

C - F8
1 Forman
2 Carpenters
3 Laboourers II
2 Plasterers II
1 Steel Fixer (reinforcement)
Power tools

C - F9
1 Labourer Foremen
2 Skilled workers
3/8 Crane, & tools ton 80

C - F10
2 Foremen
3 Labourers II
2 Plasterers II
1 Equipment Operator II
1 Concrete pumps (small)

C - F11
½ Foreman
2 Plasterers
1 Carpenter
1 Steel Fixer (reinf)
18 Labourers II

STANDARD CREW UNIT CAPACITY UNIT CAPACITY


C - F12
1 Foreman
1 Carpenter II
1 Carpenter helper
2 Mason helper
1 Steel fixer (reinf)
1 Steel fixer helper
1 Equipment Operator I
2 Vibrator Operators
1 Labourer Foreman
35 Labourers
1 Mixer
2 Vibrators

C - F13
1 Foreman
1 Carpenter II
1 Carpenter helper
2 Mason helper
1 Steel fixer (reinf)
1 Steel fixer helper
2 Equipment Operator I
2 Vibrator Operators
1 Labourer Foreman 1 Mixer 1t 500
19 Labourers 1 Front End Dumper
2 Vibrators

C - F14
1 Foreman
1 Carpenter II
1 Carpenter helper
2 Mason helper
1 Steel fixer (reinf)
1 Steel fixer helper
1 Equipment Operator I
1 Equipment Operator Ill
2 Vibrator Operators
1 Labourer Foreman 1 Mixer 1t 500
23 Labourers 1 Fixed crane
2 Vibrators

Formwork
FW - G1
3 Carpenters ll
1 Labour ll Power tools

FW - G2
1 Foreman
4 Carpenters ll
1 Labour ll Power tools

STANDARD CREW UNIT CAPACITY UNIT CAPACITY


FW - G3
1/4 Foreman
1 Carpenter
2 Helpers

FW - G4
1/4 Foreman
2 Carpenter II
2 Helpers

FW - G5
1/4 Foreman
1 Carpenter II
2 Helpers

FW - G6
1 Carpenter II
1 Helper
2 Labourers II

8) Steel Reinforcement
SR - H1
4 Steel fixer II

SR - H2
1/4 Foreman
1 Steel fixer II
1 Steel fixer I
2 Helpers
SR - H3
1 Steel fixer II
2 Helpers

Masonry
SM - 11
1/4 Foreman
1 Mason II
4 Helpers

SM - 12
1/4 Foreman
2 Mason II
4 Helpers

SM - 13
1/4 Foreman
2 Mason II
1 Chiseller
4 Helpers
STANDARD CREW UNIT CAPACITY UNIT CAPACITY
BW - J1
1 Mason II
1 Mason helper

BW J2
3 Masons II
2 Mason helpers
1/4 Carpenter (Scaffolding)

BW - J3
2 Daily
Mortar mixer It 250

Water Proofing
WP - L1
1/4 Foreman
1Roofer
2 Helper

WP - L2
1 Roof foreman
4 Roofer
2 Roofer Helpers
Application equipment

Roof and wall ckading


RWC - M1
1/4 Foreman
1 Carpenter II
3 Helpers

Carpentry and Joinery


CJ - N1
R1/4 Foreman
1 Carpenter II
1 Carpenter I
2 Helpers

CJ - N2
1/4 Foreman
1 Carpenter II
1 Carpenter I
4 Helpers

CJ - N3
1/4 Foreman
1 Carpenter II
1 Carpenter I
4 Helpers

STANDARD CREW UNIT CAPACITY UNIT CAPACITY


CJ - N4
1/4 Foreman
1 Carpenter II
4 Helpers

CJ - N5
2 Carpenter II
Power tools

Structural Steel
SS - P1
1 Foreman
1 Welder
2 Carpenters II
1 Welding Machine
14 Laboureres II

SS - P2
1 Foreman
1 Welder
2 Carpenters II
1 Welding Machine
14 Laboureres II
1 Welding Machine
1 Mobile Crane ton 20 to 45
SS -P3
1/4 Foreman
2 Carpenter II
2 Carpenter I
SS - P4
1 Foreman
2 Carpenters II
1 Welder
4 Laboureres II
1 Welding Machine
1 Mobile Crane ton 05 to 10

Metal Work
MW - Q1
1/4 Foreman
1 Carpenter II
2 Helpers
MW - Q2
1 Carpenter II
1 Helper

MW - Q3
2 Carpenter II
Power tools

STANDARD CREW UNIT CAPACITY UNIT CAPACITY


Plastering & Pointing
PP R1
1/4 Foreman
1 Plaster II
1 Chiseller
1 Helper

PP - R2
1/4 Foreman
1 Plaster II
1 Helper

PP R3
1/4 Foreman
1 Plaster II
½ Chiseller
1 Helper

PP R4
3 plaster II
2Helper
1 Mixer It 250

Floor & Wall Finsh


FWF - SI
1/4 Foreman
1 Mason II
1 Helper
1 Grinder
1 Grinder Operator

FWF - S2
1 Foreman
1 Tiler
2 Helper

FWF - S3
1/4 Foreman
1 Tiler
1 Helper
1 Grinder
1 Grinder Operation

FWF - S4
1/4 Foreman
2 Plaster II
2 Labourer II

STANDARD CREW UNIT CAPACITY UNIT CAPACITY


FWF - S5
1/4 Foreman
1 Tiler II
2 Helper

FWF - S6
1 Tiler II
1 Helper

FWF - S7
1 Brick layer
1 Helper

Painting
P - T1
1/2 Foreman
1 Painter II
1 Helper

Glazing
G - U1
1/4 Foreman
2 Glazer II
1 Helper

Sanitary Installation
SI - V1
1 Plumber II
1 Helper
1 Chiseller II

SI - V2
2 Plumber
1 Helper
1 Chiseller II
2 Electrician
2 E.Helper
2 Helper

ELI - W3
1 Electrician
1 E. Helper
2 Helper

STANDARD CREW UNIT CAPACITY UNIT CAPACITY


ELI - W4
1 Electrician
1 E. Helper
1 Helper
½ Chiseller
1/4 Plasterer

ELI - W5
1 Electrician
1 E. Helper
1 Helper

ELI - W6
.1 Electrician
.1 E. Helper
2 Helper

ELI - W7
.08 Electrician
.08 E. Helper
2 Helper

ELI - W8
.06 Electrician
.06 E. Helper
2 Helper

ELI - W9
1 Electrician
2 E. Helper
2 Helper

R3
1 Foreman
1 Electrician
½ Equip. Oper (crane)
1/4 Plasterer
½ Crane ton 5
D. Hollow block maonry for supper structure
a) 10 cm thick hollow concrete block wall bedded in cement mortar 1:4

1. Hollow block with 5 % wastage = 13 pcs/m2


2. Mortar 10mm joints and 20 % wastage = 0.0135 m3/m2.
2.1 cement = 5 kgs/m2
2.2 Sand = 0.014 m3/m2

b) 15cm thick hollow concrete block wall bedded in cement mortar 1 : 4


1. Hollow block with 5% wastage = 13 pcs/m2
2. Mortar 10 mm joints & 20% wastage = 0.0203 m3/m2

c) 20 cm thick hollow concrete block wall bedded in cement mortar 1 : 4


1. Hollow block with 5% wastage = 13 Pcs/m2.
2. Mortar 10mm joints & 20% wastage = 0.027m3/m2
2.1 cement = 10 kgs/m2
2.2 Sand = 0.028 m3/m2

4. Mortar Assuming 25% shirinkage


5% wastage

A. Cement Mortar

Material required to produice 1m3 mortar.

Item Type of work Cement ( kgs) Sand

1 Cement mortar 1:3 460 0.99

2 Cement mortar 1:4 368 1.05

3 Cement mortar 1:5 306 1.10

4 Cement mortar 1:6 263 1.13


3. Calculating materials fo masonry
A. Basic data
For one metr cube massonry work
- sub structure ( foundation wall ) = 1m3 of stone/ m3
- super structure (Semi dressed ) = 1.25m3 of stone/ m3
- super structure ( dressed ) = 1.5m3 of stone/ m3
B. Stone Masonry
a) 50 cm thick basaltic or equivalent foundation wall bedded in cement mortar 1 : 4
1. Stone = 1 m3 / m3
2. mortar = 0.4 m3 / m3
2.1 cement = 150 kgs/ m3
2.2 sand = 0.42 m3 / m3
b) 50 cm thick roughly dressed super structure stone wall bedded in cement
mortar 1 : 4
1. Stone = 1.25 m3 / m3
2. mortar = 0.4 m3 / m3
2.1 cement = 150 kgs/ m3
2.2 sand = 0.42 m3 / m3
c) 40 cm thick dressed super structure stone wall bedded in cement mortar 1 : 4

1. Stone = 1.5 m3 / m3
2. mortar = 0.4 m3 / m3
2.1 cement = 150 kgs/ m3
2.2 sand = 0.42 m3 / m3
C. Brick masonary for super - structure
a) 1/2 Brick wall bedded in compo - mortar 1: 2 : 9 sides left for plastering.
1. Brick with 5% wastage = 115 pcs/m2
2. Compo- mortar ( 10mm joints) = 0.0353 m3 / m2
2.1 Cement = 5Kgs /m2
2.2 lime = 14 kgs / m2
2.3 Sand = 0.34 m3 / m2
b) One brick wall bedded in compo-mortar 1:2:9 both sides left for plastering.
1. Brick with 5% wastage = 115 pcs /m2
2. Compo- mortar with 15% wastage = 0.085 m3 / m2 ( 10mm joints)
2.1 Cement = 12.5 kgs/m2
2.2 lime = 34 kgs/ m2
2.3 Sand = 0.081 m3 / m2
c) 1 1/2 brick wall bedded in compo-mortar 1:2:9 both sides left for plastering
1. Brick with 5% wastage = 173 pcs / m2
2. Compo - mortar with 15% wastage = 0.113 m3 /m2
2.1 Cement = 17 kgs / m2
2.2 lime = 45 kgs/ m2
2.3 Sand = 0.11 m3 / m2
C. LIME - MORTAR PLASTERING ON WALLS PER 10 SQUARE METERS

5 mm thick with 15 % wastage 10 mm thick with 15 % wastage 12 mm thick with 15 % wastage


mortar = 0.0575 m3 mortar = 0.115 m3 mortar = 0.138 m3
Proportion of
lime mortar

Lime sand Lime sand Lime sand


( Kgs) ( m3) ( Kgs) ( m3) ( Kgs) ( m3)

1:2 45.88 0.048 91.77 0.097 110.12 0.116

1:3 25.36 0.054 50.72 0.109 60.86 0.13

1:4 27.54 0.058 55.09 0.116 666.1 0.139


B. COMPO - MORTAR PLASTERING ON WALLS PER 10 SQUARE METERS

12 mm thick with 20 % 15 mm thick with 15 % 20 mm thick with 12 % 25 mm thick with 10 %


proportio wastage mortar = 0.144 m wastage mortar = 0.172 m wastage mortar = 0.224 m wastage mortar = 0.25 m3
3 3 3

nal of Cement Lime sand Cement Lime sand Cement Lime sand Cement Lime sand
compo -
mortar ( Kgs) ( Kgs) ( m3) ( Kgs) ( Kgs) ( m3) ( Kgs) ( Kgs) ( m3) ( Kgs) ( Kgs) ( m3)

1:1:6 31.75 43.09 0.14 37.93 51.47 0.16 49.39 67.03 0.21 55.13 74.81 0.24

1: 1 :8 25.4 34.47 0.15 30.34 41.18 0.17 39.51 53.63 0.23 44.1 59.85 0.25

1:2:9 21.17 57.46 0.14 25.28 68.63 0.16 32.93 89.38 0.21 36.75 99.75 0.24

1/2 : 2 : 6 14.94 81.13 0.13 17.85 96.89 0.15 23.24 126.18 0.2 25.94 140.82 0.22
A . CEMENT - MORTAR PLASTERING ON WALLS PER 10 SQUARE METERS

Portion of
cement 12 mm thick with 20% wastages 15 mm thick with 15 % wastage 20 mm thick with 12 % wastage 25 mm thick with 10 % wastage
mortar mortar = 0.144 m3 mortar = 0.172 m3 mortar = 0.224 m3 mortar = 0.25 m3
Cement sand Cement sand Cement sand Cement sand
( Kgs) ( m3) ( Kgs) ( m3) ( Kgs) ( m3) ( Kgs) ( m3)

1:3 66.15 0.14 79.10 0.17 102.90 0.22 114.84 0.25

1:4 53.00 0.15 63.80 0.18 82.43 0.24 92.00 0.25

1:5 44.10 0.16 52.68 0.19 68.60 0.25 76.56 0.27

1:6 37.80 0.16 45.15 0.19 58.80 0.25 65.62 0.28


1. Material list Calculation for Concrete

Assuming 30% Shrinkage


5% Wastage

For : Mechanical mix Water = 0.4 - 0.5


Cement

Hand mix Water = 0.4 - 0.65


Cement

Note :- Hand mix shall only be allowed for class II concrete and shall not be allowed for concrete
of class c-20 and above.

No. Type of work Materials required to produce 1m3 concrete


Concrete C-7 Cement = 150 Kgs ( 3 bags)
Mechanical mix Sand = 773 kgs ( 0.42m3)
1
mix ratio 1 : 4: 8 Gravel = 1890 Kgs( 0.84m3)
Water = 60 liter
Concrete C-15 Cement = 200 Kgs ( 4 bags)
Mechanical mix Sand = 754 kgs ( 0.41m3)
2
mix ratio 1 : 2: 4 Gravel = 1843 Kgs( 0.82m3)
Water = 80 liter
Concrete C-20 Cement = 275 Kgs ( 5.5 bags)
Mechanical mix Sand = 718 kgs ( 0.39m3)
3
mix ratio 1 : 2: 3 Gravel = 1755 Kgs( 0.78m3)
Water = 110 liter
Concrete C-30 Cement = 325 Kgs ( 6.5 bags)
Mechanical mix Sand = 837 kgs (0.45m3)
4
mix ratio 1 : 2: 3 Gravel = 1536 Kgs(0.68m3)
Water = 130 liter
Concrete C-7 Cement = 153 Kgs ( 3.06 bags)
Hand Mix Sand = 704 kgs ( 0.38m3)
5
mix ratio 1 : 3 1/2: 8 Gravel = 1966 Kgs( 0.86m3)

Concrete C-15 Cement = 202 Kgs ( 4.04 bags)


Hand Mix Sand = 661 kgs ( 0.36m3)
6
mix ratio 1 : 2 1/2: 6 Gravel = 1536 Kgs( 0.86m3)
Water = 121 liter

You might also like