INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
1. INSITU METALLOGRAPHY.
1.1 PURPOSE OF THE EXIMINATION
TECHNICAL DATA
1 1 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
1.3 RESULT
Table 1: In-situ examination results for metallography of the Diaphragm
Equipment as follows:
12
2 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
1.4 REFERENCE
- SM Metals Handbook 09 : Metallography and Microstructure 2004.
- B.J Cane and John W., September 1992. “Remanent Life Assessment Seminar”,
- ERA Technology Leatherhead-UK22/23.
- Plant Life Assessment - Data Collection Procedure
- https://www.corrosionpedia.com/definition/6264/spheroidizing
- ECCC RECOMMENDATIONS - VOLUME 6 [Issue 1]
- Residual Life Assessment and Microstructure
14
3 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
1
4 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
500x
1
5 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
500x
Figure 3. Spot Inspection No.2, from visual inspection no corrosion or crack was
found. Microstructure is ferritic, Material good condition.
Class B condition. Etching : Kalling Reagent
1
6 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
Spot Inspection No 3
200x
500x
Figure 4. Spot Inspection No. 3 , from visual inspection no corrosion or crack was
found. The Microstructure is ferritic, grain growth occurs on the outer surface, the
increase in size of grains (crystallites) in a material at high temperature, Material
good condition Class B condition.
Etching : Kalling Reagent
1
7 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
Spot Inspection No. 4
200x
500x
Figure 5. Spot Inspection No. 4, from visual inspection no corrosion or crack was
found. The Microstructure is ferritic, Normal contdition, Class B condition. Etching :
Kalling reagent
8 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
500x
Figure 6. Spot Inspection No. 5 from visual inspection no corrosion or crack was
found. The Microstructure is ferritic with spheroidized carbide pearlite.
Class B condition. Etching : Kalling reagent
9 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
carbide
500x
Figure 7. Spot Inspection No. 6, from visual inspection no corrosion or crack was
found.
The Microstructure is ferritic with carbide. Class B condition. Etching : Kalling reagent
10 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
500x
Figure 8. Spot Inspection No. 7 , from visual inspection no corrosion or crack was
found.
11 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
500x
Figure 9. Spot Inspection No.8, from visual inspection no corrosion or crack was
found Microstructure is ferritic with spheroidized carbide pearlite, Normal conditon
Class B condition. Etching : Kalling reagent
12 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
500x
Figure 10. Spot Inspection No. 9, from visual inspection no corrosion or crack was
found. The Microstructure is ferritic small grains which has recrystallized before the
recovery process. Class B condition, Etching : Kalling reagent
13 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
200x
500x
Figure 11. Spot Inspection No. 10, from visual inspection no corrosion or crack was
found. microstructure ferritic small grains which has recrystallized before the recovery
process, initial creep will occur. Class C condition,
Etching : Kalling reagent
14 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
15 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
2. HARDNESS TESTER.
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING SERVICE INDONESIA
PT. HUMOLCO LNG INDONESIA
Report No: 02/PR-MA/JICSI-HUMOLCO/VII/2021
Material : ASTM 35GR P11 Method : Hardness Brinel Report No. : 01/HDT/JICSI/VII/21
Specification : ASTM 355 Gr P11 Hardness In Base Metal : Cast steel Date : 14/7/2021
Pipe Size : - Procedure No : 003-TES-PROC-HT
PT. JICSI PT. HUMOLCO LNG INDONESIA PT. HUMOLCO LNG INDONESIA
Prepared by Reviewed by Customer Representative
Operator
Rido Lewerissa
Date: Rido Lewerissa Date: Date:
16 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING SERVICE INDONESIA
PT. HUMOLCO LNG INDONESIA
Report No: 02/PR-MA/JICSI-HUMOLCO/VII/2021
17 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING SERVICE INDONESIA
PT. HUMOLCO LNG INDONESIA
Report No: 02/PR-MA/JICSI-HUMOLCO/VII/2021
18 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING SERVICE INDONESIA
PT. HUMOLCO LNG INDONESIA
Report No: 02/PR-MA/JICSI-HUMOLCO/VII/2021
19 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING SERVICE INDONESIA
PT. HUMOLCO LNG INDONESIA
Report No: 02/PR-MA/JICSI-HUMOLCO/VII/2021
20 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING SERVICE INDONESIA
PT. HUMOLCO LNG INDONESIA
Report No: 02/PR-MA/JICSI-HUMOLCO/VII/2021
21 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 10" Spot Inspection No 1. Measurement : Milemeters
From : Main Boiler no 1
To : Main Turbine (M/T) Surface Temp : Ambient
1 10" sch 120 21.43 18.58 18.74 18.49 18.38 18.22 18.52 18.17 18.04 17.96 17.92 17.92
2 10" sch 120 21.43 18.49 18.41 18.42 18.80 18.47 18.41 18.33 18.14 18.41 17.98 17.98
3 10" sch 120 21.43 18.52 18.51 18.29 18.36 18.18 18.43 18.25 18.81 18.06 18.14 18.06
4 10" sch 120 21.43 18.32 18.47 18.54 18.24 19.00 18.34 18.82 18.10 18.74 18.05 18.05
5 10" sch 120 21.43 18.19 18.44 18.64 18.20 18.94 18.26 18.28 18.31 18.26 18.12 18.12
6 10" sch 120 21.43 18.13 18.70 18.56 18.39 18.56 18.62 18.32 18.16 18.03 18.13 18.03
7 10" sch 120 21.43 18.32 18.37 18.94 18.37 18.50 18.46 18.53 18.53 18.33 18.25 18.25
8 10" sch 120 21.43 18.33 18.38 18.28 18.19 18.50 18.62 18.68 18.44 18.37 18.24 18.19 Highlight is spot of
9 10" sch 120 21.43 18.31 18.24 18.85 18.41 18.30 18.45 18.36 18.40 18.38 18.45 18.24 metallurgy
10 10" sch 120 21.43 18.69 18.12 18.75 18.68 18.46 18.30 18.32 18.65 18.71 18.36 18.12
11 10" sch 120 21.43 18.02 18.60 18.68 16.67 18.70 18.97 18.29 18.20 18.50 18.55 16.67 minimum thickness
12 10" sch 120 21.43 18.50 18.59 17.92 18.52 17.91 18.63 18.69 18.88 18.37 18.15 17.91
13 10" sch 120 21.43 18.50 17.58 18.64 18.65 18.60 18.66 18.80 18.81 18.40 18.16 17.58
14 10" sch 120 21.43 18.50 18.49 18.10 18.59 18.59 18.62 18.71 18.79 18.81 18.63 18.10
15 10" sch 120 21.43 18.35 18.55 19.02 18.62 18.56 18.54 17.86 18.70 18.53 18.75 17.86
16 10" sch 120 21.43 17.56 17.61 18.33 18.45 18.44 18.59 18.71 18.17 18.65 18.61 17.56
17 10" sch 120 21.43 17.85 17.85 18.25 18.61 18.57 18.62 18.54 18.41 18.66 18.61 17.85
18 10" sch 120 21.43 18.20 18.46 18.50 18.71 18.63 18.73 18.58 18.69 18.79 18.69 18.20
19 10" sch 120 21.43 18.31 18.36 18.71 18.62 18.63 18.71 18.72 18.81 18.89 18.24 18.24
20 10" sch 120 21.43 18.53 18.54 18.91 18.97 18.81 18.70 18.19 18.16 18.76 18.61 18.16
21 10" sch 120 21.43 18.36 18.41 18.61 18.46 18.47 18.91 18.71 18.31 18.61 18.16 18.16
22 10" sch 120 21.43 18.52 18.36 18.40 18.35 18.39 18.41 18.63 18.49 18.52 18.70 18.35
23 10" sch 120 21.43 18.56 18.74 18.84 18.21 18.31 18.61 18.72 18.63 18.45 18.12 18.12
24 10" sch 120 21.43 18.24 18.14 18.12 18.90 18.51 18.90 18.80 18.81 18.74 18.19 18.12
25 10" sch 120 21.43 18.19 18.22 18.26 18.38 18.44 18.65 18.83 18.18 18.36 18.68 18.18
22 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 10" Spot Inspection No 1. Measurement : Milemeters
From : Main Boiler no 1
To : Main Turbine (M/T) Surface Temp : Ambient
26 10" sch 120 21.43 18.03 17.68 17.64 18.72 18.87 18.59 18.62 18.51 18.67 18,75 17.64
27 10" sch 120 21.43 18.17 18.33 18.22 18.38 18.33 18.75 18.73 18.83 18.65 18.77 18.17
28 10" sch 120 21.43 18.10 18.52 17.55 17.60 18.40 18.57 18.07 18.66 18.43 18.53 17.55
29 10" sch 120 21.43 18.21 18.64 18.51 18.67 18.61 17.64 18.35 18.93 18.61 18.46 17.64
30 10" sch 120 21.43 18.34 18.40 18.26 18.25 18.64 18.51 18.81 18.39 18.33 18.25 18.25
31 10" sch 120 21.43 17.98 17.22 17.39 18.91 17.75 17.70 17.55 18.35 18.28 18.51 17.22
32 10" sch 120 21.43 18.02 17.28 18.20 17.20 17.38 18.61 18.39 17.91 17.65 18.03 17.28
33 10" sch 120 21.43 17.62 17.23 17.95 18.23 18.63 18.23 17.81 18.21 18.20 18.61 17.23
34 10" sch 120 21.43 17.28 17.45 17.30 17.96 17.91 17.39 18.11 18.08 18.11 18.13 17.28
35 10" sch 120 21.43 17.92 18.96 18.74 18.19 18.69 18.66 18.65 18.16 17.33 17.31 17.31
36 10" sch 120 21.43 18.05 18.16 18.91 17.78 18.14 18.63 18.42 17.59 18.66 18.63 17.59
37 10" sch 120 21.43 18.05 18.16 18.17 17.25 18.38 17.62 18.23 18.22 17.81 17.67 17.25
38 10" sch 120 21.43 17.84 18.21 17.59 18.33 17.49 18.49 18.23 18.34 18.49 17.51 17.49
39 10" sch 120 21.43 18.18 18.23 18.21 18.23 18.71 18.62 18.77 18.95 18.03 18.19 18.03
40 10" sch 120 21.43 18.36 18.54 18.19 18.87 18.77 18.09 18.36 18.01 18.16 18.44 18.01
41 10" sch 120 21.43 18.67 18.45 18.08 18.05 18.29 18.31 18.22 17.32 18.16 18.44 17.32
Result measurement:
minimum Value for UT grid Thickness measurment Is : 16.67 mm
Rachman Adrian
Date : July 13,2021 Date : Date :
23 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 1
24 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 10" Spot Inspection No 2 Measurement : Milemeters
From : Main Boiler no 2
To : SSTG No. 2 Surface Temp : Ambient
1 10" sch 120 21.43 17.13 18.00 17.09 17.13 17.04 17.05 17.47 16.87 16.79 17.44 16.79
2 10" sch 120 21.43 16.92 16.93 17.25 17.70 17.47 17.83 16.75 16.82 16.72 16.80 16.72 minimum thickness
3 10" sch 120 21.43 16.75 16.85 17.03 17.28 17.10 16.83 16.96 17.32 17.77 17.44 16.75
4 10" sch 120 21.43 16.80 16.75 16.96 17.67 17.08 17.18 17.09 17.24 17.82 17.15 16.75
5 10" sch 120 21.43 17.61 16.87 17.61 17.06 17.14 17.12 18.02 17.24 17.28 17.21 16.87
6 10" sch 120 21.43 17.15 16.99 17.01 17.13 16.96 17.04 17.12 17.02 17.07 17.23 16.96
7 10" sch 120 21.43 17.11 16.97 17.29 17.20 17.41 17.18 17.14 17.19 17.26 17.69 16.97 Highlight is spot of
8 10" sch 120 21.43 17.41 17.38 17.55 17.49 17.42 17.28 17.91 17.50 17.85 18.93 17.28 metallurgy
9 10" sch 120 21.43 17.97 18.05 17.70 17.57 17.65 17.57 17.74 17.84 18.62 18.48 17.57
10 10" sch 120 21.43 17.80 17.77 17.70 17.65 17.64 17.81 18.26 18.50 18.71 18.45 17.64
11 10" sch 120 21.43 17.94 17.96 17.90 17.88 17.81 17.84 18.97 18.29 18.42 18.51 17.81
12 10" sch 120 21.43 18.81 18.23 18.58 18.07 17.83 18.01 18.90 18.00 18.14 18.15 17.83
13 10" sch 120 21.43 18.45 18.72 18.07 18.36 18.64 18.03 18.11 18.24 18.53 18.27 18.03
14 10" sch 120 21.43 18.94 18.91 18.37 18.61 18.25 18.49 17.89 18.49 18.22 18.27 17.89
15 10" sch 120 21.43 18.04 18.50 18.86 18.66 18.77 18.63 18.21 18.85 18.80 17.78 17.78
16 10" sch 120 21.43 18.25 18.02 18.69 18.87 18.92 18.48 18.31 18.59 18.58 18.20 18.02
17 10" sch 120 21.43 18.05 18.49 18.53 18.31 18.08 18.97 18.00 18.70 18.05 18.27 18.05
18 10" sch 120 21.43 18.54 18.64 18.74 18.73 18.75 18.75 19.52 18.13 18.08 18.99 18.08
19 10" sch 120 21.43 18.41 18.63 18.37 18.62 18.86 18.06 18.27 18.99 18.09 18.18 18.06
20 10" sch 120 21.43 18.53 18.46 18.51 18.26 18.60 18.14 18.73 18.96 18.77 18.60 18.14
21 10" sch 120 21.43 18.47 18.48 18.32 18.39 18.91 18.17 18.05 18.57 17.90 18.67 17.90
22 10" sch 120 21.43 18.14 18.05 18.02 18.61 18.11 18.20 18.21 18.20 18.03 17.80 17.80
23 10" sch 120 21.43 18.12 18.20 18.63 18.58 18.22 17.92 18.69 17.95 18.18 18.16 17.92
24 10" sch 120 21.43 17.84 18.51 17.89 17.86 17.72 18.62 18.19 17.95 17.91 18.50 17.72
25 10" sch 120 21.43 17.93 17.95 17.78 17.71 17.76 17.69 18.59 17.88 18.57 17.94 17.69
26 10" sch 120 21.43 17.74 17.78 17.86 18.46 18.52 18.54 18.03 18.03 18.01 18.03 17.74
25 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
27 10" sch 120 21.43 17.61 18.58 17.68 17.49 18.59 17.77 17.94 18.20 17.84 17.72 17.49
28 10" sch 120 21.43 17.51 17.52 17.44 17.65 17.48 17.51 17.47 17.83 17.84 17.97 17.44
29 10" sch 120 21.43 17.21 17.49 17.32 17.98 17.95 17.62 17.80 17.39 17.53 17.66 17.21
30 10" sch 120 21.43 16.85 16.91 16.86 17.17 17.91 17.39 17.79 17.61 17.48 17.37 16.85
31 10" sch 120 21.43 17.96 17.23 17.11 17.41 17.02 17.46 17.36 17.31 17.28 17.18 17.02
32 10" sch 120 21.43 17.69 17.04 16.95 17.01 17.75 17.25 18.43 17.44 17.25 17.24 16.95
33 10" sch 120 21.43 17.62 17.23 17.95 18.23 18.63 18.23 17.81 18.21 18.20 18.61 17.23
34 10" sch 120 21.43 17.28 17.45 17.30 17.96 17.91 17.39 18.11 18.08 18.11 18.13 17.28
35 10" sch 120 21.43 17.92 18.96 18.74 18.19 18.69 18.66 18.65 18.16 17.33 17.31 17.31
36 10" sch 120 21.43 18.05 18.16 18.91 17.78 18.14 18.63 18.42 17.59 18.66 18.63 17.59
37 10" sch 120 21.43 18.05 18.16 18.17 17.25 18.38 17.62 18.23 18.22 17.81 17.67 17.25
38 10" sch 120 21.43 17.84 18.21 17.59 18.33 17.49 18.49 18.23 18.34 18.49 17.51 17.49
39 10" sch 120 21.43 18.18 18.23 18.21 18.23 18.71 18.62 18.77 18.95 18.03 18.19 18.03
40 10" sch 120 21.43 18.36 18.54 18.19 18.87 18.77 18.09 18.36 18.01 18.16 18.44 18.01
41 10" sch 120 21.43 18.67 18.45 18.08 18.05 18.29 18.31 18.22 17.32 18.16 18.44 17.32
Note :
minimum Value for UT grid Thickness measurment Is : 16.72 mm
Rachman Adrian
Date : July 13, 2021 Date : Date :
26 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 2 UT Grid Activity on Spot No 2
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 10" Spot Inspection no 2 P &ID NO. : -
FROM : Main Boiler No.2 :
TO : SSTG No.2 DATE OF INSP. : July 13,2021 PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
27 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 5" Spot Inspection no 3 Measurement : Milemeters
From : Main Boiler No.2
To : SSTG No.2 Surface Temp : Ambient
1 5" sch 120 12.70 11.57 11.21 11.19 11.06 11.01 11.14 11.16 11.24 11.26 11.28 11.01
2 5" sch 120 12.70 11.20 11.04 11.20 11.30 11.37 11.48 11.50 11.45 11.35 11.21 11.04
3 5" sch 120 12.70 11.27 11.04 11.35 11.66 11.61 11.57 11.21 11.27 11.18 11.19 11.04
4 5" sch 120 12.70 11.09 11.18 11.48 11.60 11.32 11.31 11.28 11.06 10.88 10.84 10.84
5 5" sch 120 12.70 10.73 11.11 11.30 11.52 11.52 11.62 10.90 11.36 11.02 10.96 10.73
6 5" sch 120 12.70 11.45 11.67 11.92 11.59 11.60 11.63 11.64 11.67 11.66 11.39 11.39 Highlight is spot of
7 5" sch 120 12.70 11.13 11.44 11.26 11.27 11.34 11.44 11.93 11.78 11.72 11.77 11.13 metallurgy
8 5" sch 120 12.70 11.31 11.79 11.22 11.14 11.26 11.63 11.88 11.65 11.73 11.72 11.14
9 5" sch 120 12.70 11.44 11.43 11.42 11.30 11.24 11.75 11.79 11.67 11.70 11.71 11.24
10 5" sch 120 12.70 11.32 11.38 11.45 11.53 11.06 11.89 11.40 11.71 11.64 11.57 11.06
11 5" sch 120 12.70 11.47 11.50 11.50 11.24 11.41 11.71 11.52 11.43 11.37 11.31 11.24
12 5" sch 120 12.70 11.15 11.20 11.19 11.01 11.12 11.24 11.43 11.33 11.96 10.19 10.19 minimum thickness
13 5" sch 120 12.70 11.81 11.24 11.00 11.91 11.42 11.41 11.45 11.46 11.67 11.61 11.24
14 5" sch 120 12.70 11.36 11.49 11.40 11.20 11.46 11.20 11.45 11.47 11.30 11.57 11.20
15 5" sch 120 12.70 11.24 11.33 11.29 11.30 11.59 11.55 11.36 11.79 11.51 11.49 11.24
16 5" sch 120 12.70 10.39 11.10 10.96 11.27 11.35 11.05 11.43 11.38 11.34 11.22 10.39
17 5" sch 120 12.70 11.05 11.20 11.43 11.21 11.17 11.66 11.13 11.44 11.34 11.05 11.05
18 5" sch 120 12.70 11.46 11.37 11.32 11.14 11.30 11.97 11.17 11.23 11.24 11.20 11.14
19 5" sch 120 12.70 11.64 11.42 11.27 11.36 11.41 11.66 11.06 11.24 11.15 11.15 11.06
20 5" sch 120 12.70 11.81 11.64 11.93 11.33 11.20 11.65 11.51 11.61 11.70 11.35 11.20
21 5" sch 120 12.70 11.58 11.77 11.30 11.42 11.52 11.69 11.52 11.61 11.72 11.72 11.30
22 5" sch 120 12.70 11.37 11.41 11.47 11.59 11.59 11.63 11.41 11.44 11.33 11.38 11.33
23 5" sch 120 12.70 11.76 11.68 11.90 11.56 11.49 11.25 11.39 11.49 11.37 11.36 11.25
24 5" sch 120 12.70 11.93 11.82 11.64 11.81 11.96 11.76 11.73 11.55 11.54 11.48 11.48
25 5" sch 120 12.70 11.79 11.82 11.67 11.22 11.45 11.41 11.27 11.37 11.65 11.54 11.22
Note :
minimum Value for UT grid Thickness measurment Is : 10.19 mm
Rachman Adrian
Date : July 13, 2021 Date : Date :
28 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 3
PICTURE REPORT
PROJECT : Vessel LNG Aquarius LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 5" Spot Inspection No 3 P &ID NO. : -
FROM : Main Boiler No.2 :
TO : SSTG No.2 DATE OF INSP. : July 13,2021 PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
29 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 5" Spot Inspection No 4 Measurement : Milemeters
From : Main Boiler No.2
To : SSTG No.2 Surface Temp : Ambient
1 5" sch 120 12.50 11.31 11.33 11.07 11.17 11.23 11.01 11.23 11.15 11.17 11.09 11.01
2 5" sch 120 12.50 10.97 11.11 11.16 11.07 11.17 11.16 11.05 11.18 11.13 11.05 10.97 Minimum thikness
3 5" sch 120 12.50 11.01 11.01 11.02 10.93 11.07 10.94 11.06 11.02 11.15 11.05 10.93
4 5" sch 120 12.50 11.05 11.08 11.13 11.10 11.17 11.10 11.17 11.11 11.24 11.13 11.05
5 5" sch 120 12.50 11.17 11.06 11.15 11.13 11.20 11.14 11.24 11.17 11.29 11.22 11.06
6 5" sch 120 12.50 11.00 11.00 11.20 11.15 11.14 11.11 11.15 11.11 11.16 11.15 11.11
7 5" sch 120 12.50 11.01 11.09 11.22 11.20 11.10 11.17 11.24 11.21 11.17 11.23 11.01
8 5" sch 120 12.50 11.21 11.15 11.22 11.22 11.14 11.15 11.20 11.25 11.11 11.16 11.11
9 5" sch 120 12.50 11.27 11.38 11.63 11.69 11.17 11.88 11.50 11.60 11.21 11.77 11.17
10 5" sch 120 12.50 11.58 11.61 11.90 11.88 11.15 11.62 11.88 11.90 11.25 11.63 11.15
11 5" sch 120 12.50 11.88 11.81 11.89 11.88 11.88 11.88 11.87 12.03 11.17 12.04 11.17
12 5" sch 120 12.50 11.83 11.95 11.89 11.88 11.86 11.86 11.96 11.90 11.89 11.87 11.83
13 5" sch 120 12.50 12.00 12.25 11.00 12.05 11.97 11.97 12.26 12.26 11.99 11.85 11.85
14 5" sch 120 12.50 12.35 12.40 12.08 12.20 12.08 12.08 12.17 12.17 11.94 12.24 11.94
15 5" sch 120 12.50 11.11 12.30 12.10 12.11 12.09 12.09 12.25 12.27 12.32 12.33 11.11
16 5" sch 120 12.50 12.13 12.38 12.17 12.69 12.27 12.27 12.18 12.25 12.19 12.19 12.13
17 5" sch 120 12.50 12.45 12.32 12.14 12.29 12.33 12.32 12.25 12.12 12.30 12.41 12.12
18 5" sch 120 12.50 11.49 12.38 12.40 12.33 12.28 12.32 12.22 12.25 12.28 12.28 11.49
19 5" sch 120 12.50 12.34 12.20 12.01 12.08 12.07 12.54 12.15 11.97 12.33 12.19 11.97
20 5" sch 120 12.50 11.34 12.08 12.03 12.14 12.16 12.06 11.97 12.03 11.72 12.03 11.34
21 5" sch 120 12.50 11.94 11.99 11.85 11.99 11.70 11.71 12.23 12.11 11.79 11.73 11.70
22 5" sch 120 12.50 11.71 12.39 11.61 11.58 11.58 12.17 11.70 11.68 11.59 11.66 11.58
23 5" sch 120 12.50 11.64 11.91 12.17 11.90 11.81 11.86 11.77 11.84 11.88 11.69 11.64 Highlight is spot of
24 5" sch 120 12.50 11.54 11.61 11.61 11.74 11.55 11.86 11.54 11.50 11.70 11.61 11.50 metallurgy
Note :
minimum Value for UT grid Thickness measurment Is : 10.93 mm
Rachman Adrian
Date : July 13, 2021 Date : Date :
30 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 4
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 5" Spot Inspection No 4 P &ID NO. : -
FROM : Main Boiler No.2
31 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 5" Spot Inspection No 5 Measurement : Milemeters
From : Main Boiler No.2
To : SSTG No.2 Spot No.4 Surface Temp : Ambient
1 5" sch 120 12.70 11.86 11.90 11.50 11.56 11.50 11.65 11.54 11.64 11.54 11.70 11.54
2 5" sch 120 12.71 11.71 11.90 11.64 11.54 11.54 11.64 11.70 11.81 11.64 11.45 11.45
3 5" sch 120 12.72 11.50 11.45 11.61 11.36 11.64 11.40 11.44 11.45 11.66 11.64 11.36
4 5" sch 120 12.73 11.09 11.52 11.55 11.44 11.49 11.43 11.36 11.44 11.44 12.06 11.09
5 5" sch 120 12.74 11.55 11.51 11.50 11.50 11.38 11.42 11.30 11.48 11.40 11.44 11.30
6 5" sch 120 12.75 11.33 11.31 11.28 11.29 11.49 11.47 11.21 11.28 11.71 11.24 11.21
7 5" sch 120 12.76 11.28 11.30 11.34 11.29 11.15 11.25 11.29 11.02 11.15 11.21 11.02
8 5" sch 120 12.77 11.06 11.10 11.20 11.11 11.12 11.18 11.06 11.04 11.02 11.10 11.02
9 5" sch 120 12.78 10.95 10.98 10.92 10.92 11.01 10.95 11.05 11.15 11.17 11.02 10.92
10 5" sch 120 12.79 11.10 11.12 11.09 11.15 11.15 11.15 11.14 11.09 11.07 11.06 11.06
11 5" sch 120 12.80 10.97 11.06 11.18 11.03 11.06 11.08 11.12 11.05 10.86 11.00 10.86
12 5" sch 120 12.81 10.98 10.87 10.83 10.92 10.93 11.02 10.92 10.73 10.87 10.88 10.73 Minimum thikness
13 5" sch 120 12.82 10.94 11.00 10.97 10.94 11.03 11.06 11.04 10.93 11.16 10.98 10.93
14 5" sch 120 12.83 10.95 10.94 10.93 11.00 11.71 11.70 11.15 11.11 11.00 10.97 10.93
15 5" sch 120 12.84 11.02 11.10 11.08 11.18 11.16 11.21 11.25 11.22 11.25 11.09 11.02
16 5" sch 120 12.85 10.82 10.91 11.06 11.09 11.11 11.07 11.50 11.18 11.09 11.05 10.82
17 5" sch 120 12.86 10.93 11.01 11.01 11.08 11.01 11.12 11.02 11.07 11.02 11.05 10.93
18 5" sch 120 12.87 11.20 11.27 11.13 11.21 11.18 11.18 11.14 11.20 11.21 11.14 11.13
19 5" sch 120 12.88 11.03 11.14 11.13 11.21 11.21 11.22 11.34 11.16 11.18 11.10 11.03
20 5" sch 120 12.89 11.01 11.08 11.20 11.15 11.09 11.13 11.17 11.12 11.14 11.07 11.01
21 5" sch 120 12.90 11.10 11.09 11.12 11.09 11.20 11.19 11.25 11.25 11.19 11.14 11.09
22 5" sch 120 12.91 11.01 11.12 11.10 11.08 11.13 11.15 11.16 11.20 11.28 11.25 11.01
23 5" sch 120 12.92 11.19 11.16 11.26 11.20 11.17 11.19 11.18 11.17 11.37 11.19 11.16 Highlight is spot of
24 5" sch 120 12.93 11.31 11.23 11.35 11.44 11.45 11.57 11.57 11.25 11.25 11.36 11.23 metallurgy
Note:
minimum Value for UT grid Thickness measurment Is : 10.73 mm
Rachman Adrian
Date : July 13, 2021 Date : Date :
32 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia
, Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 5
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 5" Spot Inspection no 5 P &ID NO. : -
FROM : Main Boiler No.2
33 33Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assessment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 5" Spot Inspection No.6 Measurement : Milemeters
From : Main Boiler No.1
To : SSTG No.1 Surface Temp : Ambient
1 5" sch 120 12.70 11.26 11.29 11.21 11.27 11.23 11.11 11.21 11.1 11.26 11.12 11.10
2 5" sch 120 12.70 11.06 11.14 11.02 11.03 11.05 10.79 10.99 10.98 11.05 10.83 10.79
3 5" sch 120 12.70 11.08 11.16 11.09 11.44 10.99 10.95 11.03 11.06 11.10 10.92 10.92
4 5" sch 120 12.70 10.92 11.24 11.26 10.99 10.17 10.94 11.01 11.47 11.69 10.82 10.17
5 5" sch 120 12.70 10.84 10.87 11.49 10.82 10.91 10.72 10.91 10.81 10.94 10.82 10.72
6 5" sch 120 12.70 10.74 10.86 10.82 10.79 10.64 10.76 10.61 10.69 10.71 10.72 10.61 Highlight is spot of
7 5" sch 120 12.70 10.79 10.92 10.81 10.88 10.98 10.86 10.90 10.91 10.69 10.70 10.69 metallurgy
8 5" sch 120 12.70 10.82 10.90 10.95 10.87 10.83 10.99 10.93 10.91 10.80 10.90 10.80
9 5" sch 120 12.70 10.96 10.97 10.90 10.89 10.83 10.85 10.84 10.87 10.78 10.98 10.78
10 5" sch 120 12.70 10.92 10.77 10.85 10.85 10.07 10.92 10.92 10.72 10.87 10.90 10.07 minimum thickness
11 5" sch 120 12.70 11.05 10.95 11.10 10.95 11.30 11.27 11.37 11.31 11.21 11.37 10.95
12 5" sch 120 12.70 11.08 11.23 11.28 11.19 11.29 11.24 11.33 11.49 11.49 11.62 11.08
13 5" sch 120 12.70 11.84 11.31 11.34 11.47 11.33 11.51 11.41 11.48 11.45 11.53 11.31
14 5" sch 120 12.70 11.37 11.33 11.45 11.47 11.50 11.49 11.41 11.61 11.43 11.52 11.33
15 5" sch 120 12.70 11.32 11.43 11.48 11.50 11.57 11.49 11.62 11.68 11.77 11.61 11.32
16 5" sch 120 12.70 11.53 11.38 11.50 11.44 11.55 11.75 11.81 11.82 11.82 12.03 11.38
17 5" sch 120 12.70 11.65 11.82 11.74 11.95 11.69 11.73 12.04 11.77 11.87 11.81 11.65
18 5" sch 120 12.70 11.94 11.87 11.87 12.04 12.21 12.10 12.07 11.29 12.04 12.21 11.29
19 5" sch 120 12.70 12.02 11.91 12.10 12.01 11.63 11.30 11.25 12.14 11.85 11.83 11.25
20 5" sch 120 12.70 11.61 12.38 12.08 11.55 11.54 11.71 11.93 11.81 11.89 11.90 11.54
21 5" sch 120 12.70 11.97 11.74 11.71 11.76 11.85 11.91 11.80 11.94 11.80 11.61 11.61
22 5" sch 120 12.70 11.60 11.58 11.49 12.16 11.42 11.70 11.43 11.46 11.57 11.44 11.42
23 5" sch 120 12.70 11.59 11.60 11.38 11.65 11.60 11.69 11.41 11.47 11.98 11.57 11.38
24 5" sch 120 12.70 11.47 11.49 11.92 11.54 11.52 11.41 11.51 11.41 11.37 11.44 11.37
Recommendation:
minimum Value for UT grid Thickness measurment Is : 10.07 mm
34 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia , Copy And
Reproduce Is Prohibited Without Written Permission
Spot Inspection No 6
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 5" Spot Inspection No 6 P &ID NO. : -
FROM : Main Boiler No.1 :
TO : SSTG No.1 DATE OF INSP. : July 14,2021 PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
35 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 5" Spot Inspection No.7 Measurement : Milemeters
From : Main Boiler No.2
To : 2-MS-13 to MS-14 to SSTG No.2 Surface Temp : Ambient
1 5" sch 120 12.70 11.55 11.52 11.55 11.63 11.67 11.59 11.56 11.64 11.48 11.57 11.48
2 5" sch 120 12.70 11.53 11.52 11.42 11.50 11.42 11.47 11.39 11.48 11.39 11.46 11.39
3 5" sch 120 12.70 11.61 11.45 11.53 11.35 11.37 11.44 11.53 11.47 11.43 11.67 11.35
4 5" sch 120 12.70 11.86 11.53 11.48 11.42 11.58 11.60 11.65 11.60 11.44 11.65 11.42
5 5" sch 120 12.70 11.53 11.65 11.35 11.91 11.43 11.46 11.38 11.58 11.39 11.45 11.35
6 5" sch 120 12.70 11.36 11.43 11.31 11.25 11.46 11.34 11.43 11.56 11.46 11.45 11.25
7 5" sch 120 12.70 11.42 11.38 11.48 11.47 11.49 11.45 11.59 11.66 11.59 11.51 11.38
8 5" sch 120 12.70 11.41 11.51 11.68 11.56 11.48 11.43 11.53 11.51 11.68 11.49 11.41
9 5" sch 120 12.70 11.57 11.56 11.48 11.49 11.49 11.47 11.50 11.54 11.48 11.41 11.41
10 5" sch 120 12.70 11.41 11.52 11.43 11.42 11.51 11.65 11.58 11.65 11.52 11.56 11.41
11 5" sch 120 12.70 11.49 11.53 11.49 11.52 11.58 11.62 11.54 11.60 11.66 11.72 11.49
12 5" sch 120 12.70 11.57 11.64 11.67 11.63 11.62 11.73 11.63 11.67 11.74 11.56 11.56
13 5" sch 120 12.70 11.72 11.68 11.67 11.73 11.57 11.69 11.83 11.62 11.73 11.57 11.57
14 5" sch 120 12.70 11.44 11.52 11.60 11.59 11.59 11.70 11.64 11.65 11.61 11.49 11.44
15 5" sch 120 12.70 11.42 11.54 11.62 11.63 11.65 11.64 11.74 11.65 11.63 11.63 11.42
16 5" sch 120 12.70 11.72 11.59 11.75 11.63 11.85 11.73 11.81 11.40 11.73 11.87 11.40
17 5" sch 120 12.70 11.74 11.83 11.80 11.80 11.75 11.78 11.81 11.78 11.79 11.66 11.66
18 5" sch 120 12.70 11.97 11.09 11.91 11.92 11.52 11.78 11.83 11.81 11.79 11.78 11.09 minimum thickness
19 5" sch 120 12.70 11.92 11.97 11.88 11.82 11.92 11.83 11.86 11.88 11.79 11.84 11.79
20 5" sch 120 12.70 11.85 11.89 11.85 11.96 11.93 11.96 11.69 11.75 11.79 11.80 11.69
21 5" sch 120 12.70 11.94 11.86 11.87 11.95 11.90 11.79 11.82 11.81 11.88 11.74 11.74
22 5" sch 120 12.70 11.94 11.78 11.79 11.68 11.78 11.70 11.84 11.69 11.64 11.71 11.64
23 5" sch 120 12.70 11.87 11.87 11.75 11.66 11.83 11.66 11.75 11.70 11.55 11.63 11.55 Highlight is spot of metallurgy
24 5" sch 120 12.70 11.86 11.90 11.88 11.88 11.83 11.69 11.53 11.26 11.46 11.52 11.26
Note:
minimum Value for UT grid Thickness measurment Is : 11.09 mm
Rachman Adrian
Date : July 14,2021 Date : Date :
36 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service
Indonesia , Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 7
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 5" Spot on Inspection No.7 P &ID NO. : -
FROM : Main Boiler No.2 :
37 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assessment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 4" Spot Inspection No 8 Measurement : Milemeters
From : Main Boiler No.2
To : Steam drum / SSTG No.2 Surface Temp : Ambient
1 4" sch 120 11.12 8.84 8.90 8.18 8.99 8.93 8.90 8.91 8.90 8.18 minimum thickness
2 4" sch 120 11.12 8.83 8.97 8.90 8.92 8.89 8.90 8.96 8.90 8.83
3 4" sch 120 11.12 8.89 8.87 8.73 8.89 8.93 8.87 8.88 8.87 8.73
4 4" sch 120 11.12 8.79 8.87 8.79 8.86 8.77 8.79 8.82 8.82 8.77
5 4" sch 120 11.12 8.71 8.87 8.78 8.83 8.73 8.72 8.71 8.74 8.71
6 4" sch 120 11.12 8.70 8.87 8.80 8.67 8.72 8.64 8.74 8.73 8.64
7 4" sch 120 11.12 8.97 8.23 8.64 8.68 8.65 8.68 8.67 8.65 8.23
8 4" sch 120 11.12 8.63 8.62 8.64 8.59 8.64 8.55 8.74 8.51 8.51
9 4" sch 120 11.12 8.45 8.47 8.47 8.53 8.57 8.55 8.90 8.83 8.45
10 4" sch 120 11.12 8.79 8.83 8.79 8.84 8.98 8.85 8.92 8.89 8.79
11 4" sch 120 11.12 8.97 8.92 8.84 8.87 8.95 8.85 8.95 8.47 8.47
12 4" sch 120 11.12 8.88 8.87 8.84 8.85 8.99 8.97 8.87 8.93 8.84
13 4" sch 120 11.12 8.89 8.87 8.97 8.99 8.97 8.97 8.97 8.95 8.87
14 4" sch 120 11.12 8.92 8.54 8.63 8.95 8.97 8.99 8.92 9.04 8.54 Highlight is spot of
15 4" sch 120 11.12 9.02 8.98 9.82 9.04 9.12 9.07 9.14 9.14 8.98 metallurgy
16 4" sch 120 11.12 9.15 9.16 9.15 9.13 9.20 9.10 9.15 9.10 9.10
17 4" sch 120 11.12 9.29 9.35 9.33 9.32 9.60 9.42 9.23 9.26 9.23
18 4" sch 120 11.12 9.28 9.40 9.41 9.25 9.34 9.26 9.22 9.37 9.22
Recommendation:
minimum Value for UT grid Thickness measurment Is : 8.18 mm
Inspector Review Client
Rachman Adrian
Date : July 14,2021 Date : Date :
38 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 8
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 5" Spot Inspection No 8 P &ID NO. : -
FROM : Main Boiler No.1 :
39 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 5" spot inspection No.9 Measurement : Milemeters
From : Main Boiler No.1 & no 2
To : SSTG No.1 Surface Temp : Ambient
1 4" sch 120 11.12 7.87 7.89 7.94 8.16 8.03 8.16 8.26 8.04 7.87 minimum thickness
2 4" sch 120 11.12 8.08 8.16 8.09 8.11 8.11 8.28 8.33 8.31 8.08
3 4" sch 120 11.12 8.25 8.33 8.28 8.29 8.24 8.54 8.41 8.27 8.24
4 4" sch 120 11.12 8.33 8.51 8.43 8.42 8.46 8.50 8.52 8.53 8.33
5 4" sch 120 11.12 8.58 8.58 8.67 8.33 8.69 8.85 8.71 8.62 8.33
6 4" sch 120 11.12 8.57 8.76 8.76 8.78 8.77 8.83 8.88 8.66 8.57
7 4" sch 120 11.12 8.44 8.81 8.83 8.86 8.81 8.79 8.88 8.83 8.44
8 4" sch 120 11.12 8.67 8.68 8.86 8.95 8.84 8.89 8.84 8.72 8.67
9 4" sch 120 11.12 8.34 8.70 8.77 8.70 8.57 8.76 8.44 8.72 8.34
10 4" sch 120 11.12 8.76 8.78 8.95 8.93 8.06 8.93 8.84 8.97 8.06
11 4" sch 120 11.12 8.93 8.50 8.97 8.96 8.91 8.86 8.04 8.85 8.04
12 4" sch 120 11.12 8.84 8.94 8.95 8.98 8.92 8.98 8.11 8.85 8.11
13 4" sch 120 11.12 8.73 8.84 8.83 8.89 8.98 8.83 8.85 8.77 8.73 Highlight is spot of
14 4" sch 120 11.12 8.35 8.68 8.80 8.69 8.78 8.58 8.71 8.89 8.35 metallurgy
15 4" sch 120 11.12 8.37 8.49 8.63 8.54 8.76 8.60 8.70 8.54 8.37
16 4" sch 120 11.12 8.00 8.18 8.25 8.35 8.03 8.25 8.20 8.51 8.00
Note :
minimum Value for UT grid Thickness measurment Is : 7.87 mm
Rachman Adrian
Date : July 14,2021 Date : Date :
40 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 9
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 5" Spopt Inspection No 9 P &ID NO. : -
FROM : Main Boiler No.2 :
41 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness Grid
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Client : PT. Japan Inspection Cosulting Service Indonesia Equipment : Olypus 38DL plus
Project : Material Assesment for Superheater steam pipe. Probe Number : D790
Location : Vessel LNG Aquarius Cal. Block : Step Wadge
P & ID No. : - Couplant : Grase
Line Number : Line Pipe 10" Spot Inspection No 10 Measurement : Milemeters
From : Main Boiler No1 and No.2
To : Main Turnie (M/T) Surface Temp : Ambient
1 10" sch 120 21.43 19.27 19.08 18.86 19.07 18.77 18.99 19.04 19.14 19.35 19.24 18.77
2 10" sch 120 21.43 18.81 19.04 19.06 18.86 19.02 19.19 19.15 19.22 19.18 19.01 18.81
3 10" sch 120 21.43 18.80 18.79 18.74 19.17 18.53 19.00 18.83 19.76 19.18 19.28 18.53
4 10" sch 120 21.43 18.72 18.78 18.77 18.86 18.96 18.94 18.91 18.90 19.03 19.08 18.72
5 10" sch 120 21.43 18.61 18.63 18.70 18.65 18.85 18.82 19.10 19.35 19.35 19.32 18.61
6 10" sch 120 21.43 18.81 19.18 18.90 19.92 19.07 19.14 19.20 19.08 19.28 19.22 18.81
7 10" sch 120 21.43 18.45 19.12 19.17 19.01 19.04 19.17 18.89 19.71 18.95 18.91 18.45
8 10" sch 120 21.43 18.64 19.80 18.99 18.84 19.46 18.92 19.79 18.95 18.83 18.71 18.64
9 10" sch 120 21.43 18.46 19.49 18.86 19.67 18.92 18.97 18.74 18.92 18.62 18.57 18.46
10 10" sch 120 21.43 18.61 18.64 18.81 19.69 18.87 19.37 18.70 19.21 19.24 18.51 18.51
11 10" sch 120 21.43 18.35 18.90 19.01 18.78 19.32 19.46 19.55 18.26 18.98 18.30 18.26
12 10" sch 120 21.43 18.43 18.52 19.32 18.04 18.32 18.62 18.28 18.16 18.15 18.10 18.04
13 10" sch 120 21.43 17.92 18.04 18.02 17.64 17.73 17.70 17.68 17.80 17.69 17.78 17.64
14 10" sch 120 21.43 17.86 17.95 18.54 17.78 17.80 17.64 17.71 17.30 17.53 17.51 17.30
15 10" sch 120 21.43 19.72 17.85 17.92 17.72 17.56 17.51 17.55 17.38 17.64 17.11 17.11 minimum thickness
16 10" sch 120 21.43 17.77 17.74 17.64 18.23 18.29 18.32 17.48 17.45 17.39 17.47 17.39
17 10" sch 120 21.43 17.83 17.69 17.70 18.43 18.36 18.03 18.27 17.38 18.13 17.62 17.38
18 10" sch 120 21.43 17.73 17.57 17.57 18.12 18.24 18.00 17.70 18.21 17.55 18.35 17.55
19 10" sch 120 21.43 17.76 17.46 17.45 17.34 17.37 17.54 17.53 18.56 17.65 18.40 17.34
20 10" sch 120 21.43 17.72 18.25 17.66 17.39 17.48 17.79 17.74 17.92 17.83 17.73 17.39
21 10" sch 120 21.43 18.14 18.22 18.23 17.67 17.35 18.68 18.20 17.90 17.89 17.73 17.35
22 10" sch 120 21.43 17.53 18.63 17.66 18.30 18.30 17.72 18.21 17.66 18.24 17.66 17.53
23 10" sch 120 21.43 18.24 17.70 18.29 17.67 18.60 18.02 17.93 18.33 17.72 18.26 17.67
24 10" sch 120 21.43 17.67 17.65 17.87 17.65 17.68 17.96 18.02 17.92 17.70 17.96 17.65
25 10" sch 120 21.43 18.64 18.34 18.27 17.68 18.56 18.27 18.09 18.07 18.50 18.55 17.68
26 10" sch 120 21.43 18.43 17.75 17.86 17.65 19.18 17.95 18.81 18.37 17.97 18.29 17.65
27 10" sch 120 21.43 17.80 17.76 17.73 18.37 18.67 18.59 18.39 17.84 17.84 18.59 17.73
28 10" sch 120 21.43 18.80 18.01 17.84 17.90 18.44 18.34 18.52 17.65 17.72 17.57 17.57
29 10" sch 120 21.43 18.05 18.83 18.76 18.11 18.58 18.69 17.74 18.42 18.44 17.72 17.72
30 10" sch 120 21.43 18.25 18.37 18.90 18.83 18.09 18.17 18.93 18.05 18.16 17.88 17.88
42 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
UT Thickness
Measurement Report
PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
Note :
minimum Value for UT grid Thickness measurment Is : 17.11
Rachman Adrian
Date : July 15,2021 Date : Date :
43 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
Spot Inspection No 10
PICTURE REPORT
PROJECT : Material Assesment for Superheater steam pipe. LOCATION : Vessel LNG Aquarius
TAG/LINE NO. : Line Pipe 10" Spot Inspection No 10 P &ID NO. : -
FROM : Main Boiler No.1 And No.2 :
TO : Main Turbine (M/T) DATE OF INSP. : July 15,2021 PT.JAPAN INSPECTION CONSULTING SERVICE
PT. HUMOLCO LNG INDONESIA INDONESIA
44 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
4. MAGNETIC TEST
MAGNETIC PARTICLE
EXAMINATION REPORT
Client : PT. HUMOLCO LNG INDONESIA Report No. : 01/PR-MA/JICSI-HLI/VII/2021
Project : Material Assesment Vessel LNG Aquarius
Procedure No. : TES - MT - ASME - 01
Location : Sea of Kepulauan Seribu ASME B31.1
Date : July 15, 2021
Drawing No : - Welding Process : -
Material Spec : C/S Applicable Code : ASME V art 7
Light Equipment/S.N. : Day light Light Intensity : 1200 Lux
Brand's Name/Type : -
Ade Septian
45 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
PICTURE REPORT
Line Pipe 10" Spot No.1 Line Pipe 10" Spot No.1
Line Pipe 10" Spot No.2 Line Pipe 10" Spot No.2
Line Pipe 5" Spot No.3 Line Pipe 5" Spot No.3
Line Pipe 5" Spot No.4 Line Pipe 5" Spot No.4
46 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
PICTURE REPORT
Line Pipe 5" Spot No.5 Line Pipe 5" Spot No.5
Line Pipe 5" Spot No.6 Line Pipe 5" Spot No.6
Line Pipe 5" Spot No.7 Line Pipe 5" Spot No.7
Line Pipe 4" Spot No.8 Line Pipe 4" Spot No.8
47 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
PICTURE REPORT
Line Pipe 4" Spot No.9 Line Pipe 4" Spot No.9
Line Pipe 10" Spot No.10 Line Pipe 10" Spot No.10
48 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
Spheroidizing is performed by annealing steels with more than 0.8% carbon. The
metal is heated to a temperature of about 1200°F (650°C) and maintained at this
temperature for apredetermined amount of time to convert its microstructure. This
allows for a cementite steel structure to change from a lamella formation to an alpha
ferrite matrix.
Spherodizing is typically done on parts that have been work hardened for improved
ductility, toughness, strength and reduced hardness.
49 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
5.2 SUGGESTION
- To find out the remaining strength condition, laboratory scale mechanical testing is
recommended.
- Perform annual Inspection for monitoring condition pipe
- Recalculation engineering for integrity of pipe and remaining life.
50 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
6. DOCUMENTATION
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
6. DOCUMENTATION
Insitu Metallography.
51 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
Hardness Tester
52 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
UT Grid Measurement.
53 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Report No: 01/FIR-MA/JICSI-HUMOLCO/VII/2021
Magnetic Test.
Disclaimer:
This report reflects our findings during inspection in time and place according to the agreed scope of our
performance or deliverables and does not release buyer and/or seller from their contractual responsibilities. This
report does not construe any guarantee or warranty that the purchase contract between buyer and seller is
fulfilled correctly and all performances have been delivered without any defect. Furthermore the report and its
results does not affect any potential buyer’s right to claim for compensation or remedy towards the seller/supplier
of apparent or hidden defects not detected during our inspection or occurred afterwards.
54 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission
A B C D E F G H I J
.
.
.
.
.
1 1
2 2
3 3
4
4
5
6
Flow
55 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia ,
Copy And Reproduce Is Prohibited Without Written Permission
INSPECTION REPORT
MATERIAL ASSESSMENT
VESSEL LNG AQUARIUS
PT.JAPAN INSPECTION CONSULTING
PT. HUMOLCO LNG INDONESIA SERVICE INDONESIA
Inspected By :
NDT ASNT MT LV II
Ade Septian
Date :
Disclaimer:
This report reflects our findings during inspection in time and place according to the agreed scope of our
performance or deliverables and does not release buyer and/or seller from their contractual responsibilities. This
report does not construe any guarantee or warranty that the purchase contract between buyer and seller is
fulfilled correctly and all performances have been delivered without any defect. Furthermore the report and its
results does not affect any potential buyer’s right to claim for compensation or remedy towards the seller/supplier
of apparent or hidden defects not detected during our inspection or occurred afterwards.
56 Final Inspection Report| This Document Is Exclusive Property Of PT. Japan Inspection consulting service Indonesia,
Copy And Reproduce Is Prohibited Without Written Permission