You are on page 1of 2

001471

CERTIFICATE
OF INSPECTION
oc Certificate No.

This is to certify that


301/J B3321PV-FT/02N/2019

z- Pressure Vessel Equipment

2w Owner

User
__ --~~~~P;T~K~o~~~~i
m;n~ak
y=~ln~~1a
U"C 6~i\WaIoIIiiIWh
l-
--~~Plif;t ;a~~i~lt
l~:::.:..:.:.:=~
e- I Name of Equipm' n
Tag I Serial No.
; .t.__
L AC-TB-002 1 25/SP/2007

~
Type of Equipment Vertical

Manufacturer PT Shinnetsko Prima

~ Year of Built I Used

Location
2008/ 2008

Workshop PT Ko~minyak Internusa, JI. Raya Prancis Komplek


Pergudangan 8 Blok CD Jatimukya, Kosambi - Tangerang

" The equipment has been inspected in accordance the Inspection and Test Plan No.
181/007/BT/ITP-DMTO/2019 it is concluded that equipment was in good condition. feasable to
used and comply t go

Reference Proced re
nt reg ulation and reference(s).

Yli.
Inspection Period

Inspection Report No. JBi3


3~IP\/~rl

Certificate Issue Date May 20, 2019

SyajfrJ ah,ST t
Director V
PT FARRALD TEKNINDO This Certificate Valid Until: April 30, 2023
PT FARRALO TEKNINDO
Graha FT
Jln. Raya Pasar Minggu 104-8
Jakarta Selatan • 12520
Indonesia

~'!!!~(it)@QPJ ~
P: (021) 22708084
F: (021) 7823499
E: marke'tlng@farrald·teknindo.com
W· farrald·teknindo .com LI·133-10N ~ .. _ _ .. _ _ _ _ _ . _
DATA OF PRESSURE VESSEL

Dimention
a. Thickness (Shell I Head) 16.06 mm I 21 .03 mm
b. Size 114.30 mm (00) x 1016.00 mm (SIS)
Design Pressure 297.00 kglcm ' g
Design Temperature 65.55 ·C
Max. Allowable Working Press. 297.00 k9lcm '9
Min. Design Thickness (Shell I He d) ~. s,, _ _ I , ~ . uv I 11 .55 mm
Service Life - ... _"".,. I n IULLED eas
Operating Pressure
Operating Temperature
COr- vrOOO
..
kg/ ~ 'g
·C
­

Description PSV Test Bench Accumulator


Service Nitrogen
Test Pressure 398,66 kglcm'g
Test Media Water
Capacity 5
MAWP Recalculation 367.24 kg/cm' g •
Corrosion Rate 0.07 mmlyears
Remaining Life Calculation 49 .37 Years
Non Destructive Testing (NOT) Ultrasonic Thickness
Code or Standard ASME Sec. VIII Div I & API STD 510

~.