qMT UNDFR TEST
1 Name : Compression Machine 4 Capacity : 2000 kN
2 Type/Modet :Analog 5 Serial Number '.149321
3 Manufacture :Teguh Primatama 6 Resolution : 10 kN

OWNER
1 Name : CV Teguh Primatama

2 Address : Jl. CimareYne no.149 Bandung Barat

STANDARD
Name Manufacture/SN Traceable Sl Unit trough
1 Load Cett KELION / 5FN882 B2TKS-BPPT

Date of acceptance : June 1 1,2011 Date of catibration : June 1 1 2Oi1

Envirgnment condition of catibration

Temperature .27 t 2oC


Humidity :58t 5%
Lgcation of Calibration
Workshop CV Teguh primatama
1
Refference :JtS B 7733- 1999

Result of Cqlibration : Attached

Director

CALIBMTION II{AINTENAI{CE INSTRUMENTATION IESTEQUIPMENT MACHIMRY QUALIIYCONSIITTANT


4ZensrERIv { xast
s\PR0E]{GTNEERT}|G Komite Akreditasi Nasional
LABORATORIUljl KALIBRASI
LK.1I2 . IDN
PT EASTERN PRO ENGINEERING
Kawasan Wangsaniaga Wetan No,27
Kota Baru Parahiyangan - Bandung Barat
Telepon : 022 6803053 - Fax: 022 6803053
Website : www.easternproengineeering.com
E-mail : service@easternproengineering,com 'LAPORAN KALIBRASI
CALIBRATION REPORT
Number 0988.EPE.06.11
Date June 1 3,2011

Page 2 of 2

Unit Under Test (UUT) : Compression Machine @ nnrrl = 230 mm

Serial Number/lD :149321


Capacity : 2000 kN

Result of calibration
Standard lndication Correction Error
UUT lndication
Before After Before After Before After
Adjusting Adlusting Adjusting Adjusting Adjusting Adjusting
{kN) (kN) (kN) (kN) (kN ) (Yo) (o/")
0 0 U 00 0.0 0.0 00
200 197 204 -3 4 15 2.0
400 391 405 -9 6 -2.3 1.3
600 583 607 -17 7 -2.8 1.2
800 776 808 -24 I -3.0 1.0
1000 972 1011 -28 11 -2.8 1.1
1200 1 169 1216 -31 16 -2.6 1.3
'1400 1363 1417 -37 17 -2.6 1.2
1600 1559 1620 20 1.3

i6o;n
1600
1400
;
1200
-d
: 1000

tE 800
E ooo
>ll 400
200
0

I 0 200 400 600 800 1000 1200 1400 1600 ' 1800
I X=Stdr.lndc(kN)

Uncertainty Calibration = t 0.5 %


The Uncertainty is taken at a Convidence Level g5% and Coverage Factor ( k ) = 2

Pelaksana Teknis

Abbas Nur Utama

CALTBRATTON MAINTENAI{CE INSTRIIMEMATION IESTEQIIIPMENT MACHINERY QUAIXIYCONSITTTATTT