Development of Janus: Automated Social Distancing and Hand Hygiene

Implementation Device for Establishments and Public Spaces

G.C.L. Calub, J.A.O. Cruz, D.M. Figuracion, M.A.M. Velasquez, F.C.C. York

Abstract: Janus is a device that aids with the implementation of certain minimum health protocols, i.e. social
distancing and proper hand hygiene, specifically in establishments and certain public spaces. It does this by
automating the process of maintaining a certain capacity in the establishment, and allowing the use of hand sanitizer
without having to make contact with the pump. The device uses two modules to be able to carry out its functions,
and these are the Capacity Monitoring Module and the Automated Hand Sanitizer Module. The capacity monitoring
module utilizes Passive Infrared (PIR) motion sensors, a Serial MP3 player and a speaker, and a 20 x 4 LCD screen,
so that it is able to maintain count, and be able to remind people to follow certain minimum health protocols and
notify people if the establishment is already at capacity. The automated hand sanitizer module contains a sensor that
will detect the presence of a hand, indicating that a person wishes to use the hand sanitizer, and instructs servo
motors to automatically pump the sanitizer for them, so that they do not have to make contact with the sanitizer
pump anymore. Janus has the ability to accurately and consistently carry out its functions, such as counting,
notifying, detecting, and sanitizing, in the proper conditions or the correct situations.

Keywords: Arduino, Social Distancing, Hand Hygiene, Minimum Health Protocols, Implementation Devices,
Automated Systems, Capacity Monitoring System, Non-Contact Hand Sanitizer, Covid-19 Pandemic

1. Introduction
Biswas (2021) stated that in 2020, Philippine
The emergence of Covid-19 has brought an economy went into a deep recession because of the
unprecedented impact on businesses across industries impact of the pandemic. The Philippines’ GDP has
and as well as the individual citizens living in the contracted by 9.6% on a year-on-year basis, which
world. The World Health Organization (WHO) in was the worst annual decline that was recorded since
2021 has recorded a total of 1,184,706 confirmed the commencement of the National Accounts data
cases of Covid-19 in the Philippines from January 2, series in 1946. Additionally, Gardaworld (2021)
2020 to May 25, 2021, with about 19,983 deaths elaborates that due to this deep recession in the
reported and the estimated cases per day exceeded Philippine economy, the government had to try and
4,000. The WHO in 2020 states that countries are open the business sector in various parts of the
following the advice from them regarding the country little by little. Unfortunately, trying to
introduction of physical distancing measures and balance the strengthening of the country’s economy
frequent sanitizing as two of the ways in which and maintaining good public health has proven to be
transmission of the disease can be reduced. Health quite difficult.
and safety protocols such as social distancing of at
least one meter from each other, avoiding crowded The researchers developed a two-in-one prototype,
places, wearing face masks and face shields, rigorous named “Janus”, from the Roman god of doorways,
sanitization, and avoidance of face-to-face contact or entrances, exits, passages, and decisions where it
meetings are some that are currently being stands at the entrances and exits of establishments
implemented. Unfortunately, the implementation of firstly to make sure that the people entering the said
such regulations has led to the closing and straining establishment sanitizes his/her hand properly also, to
of educational, business, economic, local, and even monitor the amount of people inside. The prototype is
global institutions and sectors. It has also restricted a combination of an automated hand sanitizer and an
travel and social gathering amongst peers. automated minimum health protocol implementation
system which can be modified to notify people if the 2.1 Research Methodology
establishment is already at a maximum capacity by
utilizing a screen and a sound system. This could be a The major goal of this research is to create an
way to help mitigate the spread of COVID-19 during automated hand sanitizer dispenser that can stop
this new normal. viruses like COVID-19 from spreading and save
people from a pandemic. The study mainly used
The core objective for this study is to develop Janus, microcontrollers and motion sensors to create an
an automated social distancing and hand hygiene automated minimum health protocol implementation
implementation device for establishments and public system for establishments and public spaces. The
spaces, and determine its level of effectivity, level of researchers designed a device that is accessible to
sensitivity, and the theoretical level of acceptability Persons With Disabilities (PWD) by incorporating a
as a perceived proposed idea by the respondents, who visual monitor (for the hearing impaired) and a
are business/establishment owners and barangay or speaker (for the visually impaired) to assist them in
municipal health officers. utilizing it.

2. Materials and Methods The researchers used Quasi-Experimental Research


Design to predict and control the variables in the
Before reading the next section, the researchers study, as well as to determine their relationship to one
would like to mention now that there were multiple another. The goal of a quasi-experimental study is to
extenuating circumstances that occurred that have evaluate interventions without using randomization
forced the researchers to make changes and such to (Eliopoulos, G., et. al, 2004). The design is used to
what is written in the following chapters and to what find out each hardware’s effectiveness and
is seen on the device. A major one was that there was preciseness, Passive Infrared (PIR) Motion Sensors’
a defect with the LCD that the researchers were accuracy, and the device’s overall functionality. A
supposed to use, and unfortunately, this was realized series of testings have been carried out to determine
too late. An expert confirmed that the codes and the the device’s efficiency. The researchers then
device wiring was already free from error, but still compiled the results of the testing and used statistical
the LCD continued to malfunction. And despite analysis to determine the device’s performance. The
numerous methods and advice and recommendations obtained data and outcomes were subjected to several
offered by the expert that the researchers followed, procedures in order to generate interpreted data.
unfortunately, it was concluded that the LCD screen
was indeed defective. In the following chapters, the A questionnaire was used to collect information from
LCD still remains. This is because this was the the participants and evaluate their level of
original plan, and surveys were already given out and acceptability of the device in terms of efficiency,
the responses were already in, as well as the small reliability of its functioning, user-friendliness,
amount of time that the researchers had left. What the cost-effectiveness, and overall design of the
researchers would like to show in the following prototype.
chapters is what the device would be like with the
LCD. As a replacement to have an indicator that the 2.2 Subjects of the Study
device, aside from the LCD, indeed works, the
researchers have installed ten LED lights as an The respondents of the study were municipal health
indicator of the current number of people inside the officers and establishment owners from the chosen
establishment. This replacement is purely for areas. The researchers considered these people to be
demonstration purposes, as the intention with the the respondents for the entire testing period of the
device is that the maximum value could be changed device. There were a total of 14 respondents for the
at any time. study conducted: two health officers and 12
business/establishment owners, coming from the
locations specified in Section 2.3. Purposive
sampling was utilized in choosing the respondents for
the business and establishment owners, as well as the doorways or passageways. To then remind the people
municipal health office representative or officer. to follow hand hygiene protocols and social
distancing protocols, the module uses an Liquid
2.3 Locale of the Study Crystal Display (LCD) screen and a Serial MP3
Player connected to a speaker to be able to notify or
This study aimed to develop Janus, a cost-effective remind people in two different mediums, which are
Arduino-Based Automated Social Distancing and audio and visual.
Hand Hygiene Implementation Device, which was
conducted in various areas of Rizal for the S.Y. The automated hand sanitizer module is not
2020-2021. Due to time and mobility constraints, the particularly new. It utilizes a sensor to detect the
survey area that was originally supposed to be 4 presence of someone who wishes to sanitize their
municipalities in the province of Rizal, was reduced hands. Then with the help of code, the servo motors
to 2 municipalities, namely, Morong and Cainta, installed into the module will automatically pump the
Rizal. hand sanitizer for them, effectively lessening, or even
eliminating the contact needed to apply hand
sanitizer.

The device utilizes three Passive Infrared (PIR)


sensors: one to count people going through the
entrance, one to count people going through the exit,
and one in the automated hand sanitizer. It also
utilizes two MG-995 Servo Motor Towers to be able
to pump the hand sanitizer. It also utilizes a 20 x 4
Liquid Crystal Display (LCD) screen and a Serial
MP3 Player and a speaker to be able to notify people
in two separate mediums (audio and visual). And the
one that controls them all is the Arduino Mega 2560
microcontroller, a large microcontroller capable of
handling many pins. Considering that the device is a
prototype, a breadboard is also present to distribute
and increase the capacity of connections, especially
for the VCC (voltage) and GND (ground) pins.

Figure 1. Map of Rizal and the constituent areas for


survey

2.4 Design and Components

The device contains a total of two modules: the


capacity monitoring module and the automated hand
sanitizer module.

The capacity monitoring module is the device’s first


line of detection of human entry or exit from the
establishment. This module is responsible for
counting the current amount of people in the
establishment, and as well as changing that value as Figure 2. A Fritzing pin diagram of Janus, which
people enter and exit the establishment. It utilizes contains the capacity monitoring module and the
sensors to detect human movement through the automated hand sanitizer module
The sensors take in this information and process it
through the code. If a motion is detected in the
entrance sensor, the device will begin to check the
current amount of people inside of the establishment,
which is denoted by the variable humval. It then
compares it to the maximum number of people that
can be accommodated by the establishment, denoted
by the variable maxval. If humval is less than or equal
to maxval, then the device will add one to humval
using this simple formula in the codes:

humval = humval + 1 …. (1)

Figure 3. A Fritzing pin diagram of Janus, but not But if humval is already equal to maxval, then the
including the LCD screen device would utilize the audio-visual means to notify
the people that the establishment has already reached
2.4.1 Capacity Monitoring Module maximum capacity and ask the people not to enter the
establishment for the meantime.
The Capacity Monitoring Module consists of two PIR
motion sensors, one placed on the entrance of the If a motion is detected by the exit sensor, then the
establishment, and one placed on the exit. It can send device will do the opposite of what the entrance
detection information to the LCD screen and the function does: it will subtract one for every person
speaker through the microcontroller and give that leaves the building, which can be expressed
appropriate information for the notification system to mathematically as:
determine the proper action to be done.
humval = humval - 1 …. (2)
a. Passive Infrared (PIR) Motion Sensors and the
Working Logic b. Liquid Crystal Display (LCD) Screen

The researchers decided to utilize PIR motion sensors One of the mediums that the device utilizes to notify
instead of the ultrasonic motion sensors because its visitors is through visual means with the 20 x 4
firstly, the PIR motion sensor has greater range than LCD screen. The LCD screen can display various
the ultrasonic motion sensor, making it more fit to be messages, depending on the condition. It can either
attached to places that it cannot obstruct the pathway, display how many people are currently in the
such as at the top of door frames, but do its job establishment, or it can also display a warning
nevertheless. Secondly, there are too many message for the person not to enter the establishment
environmental factors that can affect the accuracy of for the time being. But due to unforeseen
data that an ultrasonic sensor can receive, such as circumstances, this component had to be removed
changing temperatures, noise from the environment, from the actual prototype.
wind, barriers, etc.
c. Serial MP3 Player and Speaker
The two PIR motion sensors work in this device by
detecting the change of infrared radiation being Another medium that the device uses to notify and
radiated from the environment due to the entry and remind its visitors is through auditory means. For
exit of specific sources from its detection range, such this, the researchers employed the use of a Serial
as biological organisms like us, humans, through MP3 Player and a speaker. The sound channel is
doorways or specific locations on the entrance and monaural, or sound created by a single speaker. The
exits of the establishments. Serial MP3 Player can house an SD card, but the
processes that can be carried out by the module are
exclusively for audio files, such as .mp3 or .wav files. and it will keep pumping until the hand is removed
The audio files are stored in the SD card, and when a from the detection range.
certain condition is met, the Serial MP3 Player can
play a certain audio file, such as reminding the person 2.4.3 Arduino Mega 2560 Microcontroller
entering to follow proper hand hygiene protocols, or
to prevent them from entering the establishment for The microcontroller board to be used to house the
the time being as the establishment is still currently at codes, the core connections, and the main distributor
maximum capacity. of power to the device is the Arduino Mega 2560
Rev3, which is based on the ATMega2560
2.4.2 Automated Hand Sanitizer microcontroller (Arduino Store, n.d.). The Mega
2560 is bigger than the commonly used Arduino Uno
The automated hand sanitizer ensures that no contact R3. According to the Arduino Store, it is capable of
has to be made with the sanitizer pump for the person housing 54 input or output pins, 16 analog input pins,
who wishes to use it. To do this, the module employs 4 hardware serial ports, and other features that you
the functions of a PIR motion sensor, and two servo would commonly see in the Arduino Uno R3. This
motors to be able to do its function. microcontroller is fitted for the device as it can
endure high performance from the multiple
a. Passive Infrared (PIR) Motion Sensor components constantly working while using low
power. It is powerful and capable, and the mass
The PIR motion sensor in this module works amount of pin capacity allows customization in the
similarly to how the PIR motion sensors work in the future.
Capacity Monitoring Module. The only difference is
that the information that it gives to the 3. Results and Discussion
microcontroller is directed to the two servo motors in
the sanitizer pump. The target to be detected by this 3.1 The Level of Acceptability
sensor is the presence of a hand. If the sensor detects
a hand, the servo motors will work and pump the The responses of those who participated in this
sanitizer for the person. If there is no hand being survey are based on a more theoretical,
detected, then the module remains stationary. idea-proposal-based perspective. To put it more
simply, the device was not developed in time for an
b. MG-995 Servo Motor Towers actual demonstration to be presented to the
respondents, therefore, the researchers had to resort
The MG-995 Servo Motor Towers are powerful to alternative methods of presentation. The
brands of a servo motor, where these motors contain researchers went with creating a visual, a 10-page
metal gears, which can produce more torque and have PDF (See Figure 3 below) that contains all the
a better gear strength, meaning that it can last longer. information that the respondents need to know about
The reason that this was what the researchers chose the device, how it works, what it is for, and a
to use was that no matter how hard the sanitizer pump theoretical idea of its effectiveness. Although, while
is to press, the powerful torque of this brand of servo unfortunately this data could be more or less
motor will be able to press it. accurate, it gives the researchers a general idea of the
people’s acceptance of the device if it ever was to be
When the PIR motion sensor detects the presence of a developed. In addition, the LCD screen that was
hand in front of it, the servo motors will rotate, and attached to the device which was supposed to display
wires connected to the pump will pull the pump various messages depending on the condition, has a
down, effectively pumping it, and then rotate back up surface defect that hinders the device to function as
to the default angle, and thus the pump returns into its designed, hence, having it to be removed from the
original position, ready to be pulled again. Now, as overall prototype.
long as the PIR motion sensor can detect a hand in
front of it, the code for the servos will keep looping,
Figure 4, a-c. Some sample pages from the PDF file
that was given to the respondents where they based
their ratings on

Table 1. Responses and their frequencies from


Section A of the survey

Legend: SN = Statement Number, fR5 = frequency of


a rating of 5, fR4 = frequency of a rating of 4, fR3 =
frequency of a rating of 3, MS = Mean Score

Data analysis through means of central tendency,


specifically, the average or mean scores of the
responses from Section A of the survey indicates that
the device is Very Acceptable. With a mean score of
4.60, in theory, the respondents were very optimistic
with what the device could be. What follows are
comments on the device by the health officers when
asked if they think that the device would be useful in
the current pandemic:
“Yes, since not everyone follows health protocols, it Table 4. Responses and their frequencies from
will be very beneficial for people because it raises Section D of the survey
awareness that also leads to everyone's safety. It is
high-tech and it makes people's lives easier.”

“Yes it will eliminate manpower and the job of


physically explaining to people when they should
enter an establishment.”
Legend: SN = Statement Number, fR5 = frequency of
Table 2. Responses and their frequencies from a rating of 5, fR4 = frequency of a rating of 4, fR3 =
Section B of the survey frequency of a rating of 3, MS = Mean Score

In terms of Janus’ overall aesthetics and design, the


proposed design of the device was rated with a mean
score of 4.61, which can be interpreted as Very
Acceptable. The proposed device, in the eyes of the
respondents, looks aesthetically pleasing and can be
Legend: SN = Statement Number, fR5 = frequency of put into an establishment and fits in with the
a rating of 5, fR4 = frequency of a rating of 4, fR3 = building’s design or decoration.
frequency of a rating of 3, MS = Mean Score
Table 5. Tabulated mean scores for each section of
The device garnered a mean score of 4.64 in Section the survey, the mean score for the whole of the
B of the survey, which can be interpreted as Very survey, and the standard deviation of the responses
Acceptable. The respondents perceived the idea of
Janus as being user-friendly. From an idea-based
perspective, the respondents view the proposed
design and functions of Janus as easy to use and
navigate.

Table 3. Responses and their frequencies from Legend: QS = Questionnaire Section, MS = Mean
Section C of the survey Score of Section..., OMS = Overall Mean Score, SD
= Standard Deviation

As a whole, the device has garnered an overall mean


score of 4.59 for the theoretical level of acceptability,
which can be interpreted as Very Acceptable. In
general, the respondents of the survey would most
Legend: SN = Statement Number, fR5 = frequency of likely use this device when given the chance. They
a rating of 5, fR4 = frequency of a rating of 4, fR3 = have rated its overall functions and utility, aesthetics,
frequency of a rating of 3, MS = Mean Score and efficiency, and arrived at the conclusion that it
can be, in fact, very useful for them as business
For this Section C of the survey, the mean score owners, and had received the approval of health
garnered from the respondents was at 4.48, which can officers as well.
be interpreted as Very Acceptable. This indicates that
theoretically, the respondents think that the proposed As for the consistency of the ratings, calculations
device is cost-efficient, and they can get good quality show that the standard deviation for the responses of
functions and utility from the device that is well the survey are at 0.54, meaning that most of the data
worth purchasing or producing. points are clustered quite closely around the overall
mean, which is 4.59. This indicates that the responses consistently individualize each person that went
were quite consistent and that the respondents were in through its entrance and exit sensors, and counting
general agreement that the device can be useful, even appropriately and giving a correct response for each
if it was just presented to them in theory. This condition, it garnered a 100% (or 10/10, 5 for each
solidifies the interpretation given for the theoretical sensor in the module) level of effectiveness when it
level of acceptability of the device. comes to maintaining capacity in establishments and
public spaces.
3.2 The Level of Effectivity and Sensitivity
As it was also able to consistently detect the presence
The tests were done at the home of one of the of a hand in its automated hand sanitizer module, and
researchers, where the device was developed. The the servo motors being able to successfully pump an
device was subjected to five rounds of testing, with appropriate amount of sanitizer for each pump done,
thorough observation of each of the device’s sensors the device has also garnered a 100% (or 5/5) level of
to check if the device functions as intended. For the effectivity for being able to implement proper hand
tests done for these factors, maxval was set at 10 hygiene.
(establishment capacity is set at 10 people). And
since maxval was set at 10, the two sensors on the Table 7. Tabulated test run results for five rounds of
capacity monitoring module were set to be tested 10 Janus’ modules, indicating the level of sensitivity of
times, where the sensor had to detect a person passing Janus’ functions and sensors
through and count them accordingly. For the entrance
sensor, an additional eleventh detection test is added
to check for the device’s monitoring and capability to
alert the person of the establishment’s maximum
capacity protocol. But the eleventh detection will not
be counted, instead, it would signify a successful
round for the sensor. The same method goes for the
hand sanitizer sensor, where the hand sanitizer had to a,b,c
The values inside the columns indicate the
detect the hand successfully five times, and pump number of true positive detections for each round
five times, to consider a round successful.
Legend: ENS = Entrance Sensor, EXS = Exit Sensor,
Table 6. Tabulated test run results for five rounds of HSS = Hand Sanitizer Sensor, TTPD = Total True
Janus’ modules, indicating the level of effectiveness Positive Detections by the sensors
of Janus’ functions
The number of true positive detections is counted for
each detection that occurred during each round. For
each round, there are a total of 25 detections.

The capacity monitoring module was able to


successfully and accurately detect all 100 detections
through its entrance and exit sensors, and as well as
individualize them by counting them all only by 1. In
Legend: ENS = Entrance Sensor, EXS = Exit Sensor, turn, this signifies a 100% (or 100/100, 50 for each
HSS = Hand Sanitizer Sensor, %LE = Level of sensor) level of sensitivity for the capacity
Effectiveness in Percentage, SUC = Successful monitoring module, and as such, means that the
Detections/Run module can successfully detect and function without
fail.
After five consecutive tests with each of Janus’
modules, the results were outstanding. With the
capacity monitoring module being able to
The hand sanitizer module was also very successful potential to be customized further, and also presents
in detection. It was able to garner a 100% (or 25/25) opportunities in adding more functions or features in
level of sensitivity. It was able to properly detect all which minimum health protocols it can automate.
of the intentions to use it without fail, and was also
able to successfully pump the appropriate amount of Due to multiple extenuating circumstances though,
sanitizer every time. the accuracy of the data could possibly be
compromised. The researchers recommend repeating
4. Conclusion these surveys and tests in a more proper context, and
on a much larger scale, so that the data can have a
In the present study, the presentation of the materials, more solid foundation. Additionally, the LCD screen
methods, and the design, and the results of the issue must be addressed to achieve the full functions
development of such a device from various tests and of the device.
surveys, have eventually led to the conclusion that
the researchers arrived at. Such a device is simple References
enough but presents a great potential for being used
as an automated implementation device that can Arduino store. (n.d.). Arduino Mega 2560 Rev3.
reduce the amount of manpower needed to implement Retrieved from
such rules and more effectively implement the https://store.arduino.cc/usa/mega-2560-r3.
protocols in place, especially during the New
Normal. Biswas, R. (2021). Philippines economy hit by rising
COVID-19 wave. Retrieved from
The device can run a real-time detection system that https://ihsmarkit.com/research-analysis/philippines-e
can accurately and consistently count the number of conomy-hit-by-rising-covid19-wave-Apr21.html.
people that are currently inside an establishment, and
also detect how many people went into and out of the Eliopoulos, G., Harris, A., Bradham, D., Baumgarten,
establishment. This function is especially useful M., Zuckerman, I., Fink, J., Perencevich, E. (2004).
during the time of the New Normal where social The Use and Interpretation of Quasi-Experimental
distancing is one of the core protocols being Studies in Infectious Diseases, Clinical Infectious
implemented to protect the people, and at the same Diseases, Volume 38, Issue 11, 1 June 2004, Pages
time, be able to reopen the country’s economic and 1586–1591, https://doi.org/10.1086/420936
business sectors. The device also features a highly
sensitive automated hand sanitizer module that can Gardaworld. (April 29, 2021). Philippines: Officials
ensure that people can use hand sanitizer while being extending varying community quarantine measures in
able to minimize contact with the pump, and in turn, most areas through May 31, with stricter rules in
is able to implement the proper hand hygiene Metro Manila through May 14. Retrieved on May 25,
protocols. 2021 from
https://www.garda.com/crisis24/news-alerts/472931/p
Janus is a reliable device that has the ability to hilippines-officials-extending-varying-community-qu
automate the implementation of minimum health arantine-measures-in-most-areas-through-may-31-wit
protocols through modules and systems. Business and h-stricter-rules-in-metro-manila-through-may-14-upd
establishment owners agree that this is a kind of ate-62.
device that should be produced and implemented for
establishments that require people to go into. Janus World Health Organization. (2020). Critical
also shows great potential for accurate and reliable preparedness, readiness and response actions for
and consistent detections that will mitigate the need COVID-19: Interim guidance 19 March 2020.
Retrieved from
of human intervention in the operation of the device.
https://www.who.int/publicationsdetail/critical-prepar
edness-readiness-and-responseactions-for-covid-19
The device also houses an Arduino Mega 2560
microcontroller, and with this, the device has the
World Health Organization. (2020). Naming the
Coronavirus Disease (COVID-19) and the Virus that
Causes it. Retrieved on May 25, 2021 from
https://www.who.int/emergencies/diseases/novel-coro
navirus-2019/advice-for-public.

World Health Organization. (2021). Philippines:


WHO Coronavirus Disease (COVID-19) Dashboard.
Retrieved on May 25, 2021 from
https://covid19.who.int/region/wpro/country/ph