The Hay Moisture Meter 1.

Features: conductivity and has


HAY TK100H is suits to many hays 1.1.It is portable, compact, automatic temperature
MOISTURE METER moisture content testing, just easy to use and the compensation.
as alfalfa, leymus chinensis, moisture measurement 1.5.Measurements are taken
orchard grass pennisetum readings are instant. by inserting the sensors
hydridum and other Hays. 1.2.Digital display with back into the bale of grains .
light gives exact and clearly 1.6.Manual off at any time
reading although you stay .Auto power off after 5
at the somber conditions. minutes from last
1.3.It will save time and operation.
expense by monitoring
dryness and helps to
prevent deterioration &
decay caused by moisture
whilst in storage, therefore
ATO-TK100H processing will be more
convenient and efficient.
1.4.The moisture meter
operates by electrical

2.Specification 3.Panel descriptions


Display:4 digital LCD
Measuring range :0-80%(CD00)
Operating conditions: 4.Operation procedure
Thanks for choosing our Temperature:-10~60°C 3-1 3-6 4.1 Turn on the key ,the
moisture meters! Humidity:5%~90%RH 3-2 symbol “0”will be showed
Resolusion:0.1 3-3 3-7 on display. It will need
For your easy to master this
instrument as soon as Accuracy: ± 0.5%n 3-8 zeroing if showed other
3-4 3-9
possible, please read Operating principle: value, please depress
3-5
following instructions E l e c t r i c a l c o n d u c t i v i t y, 3-10 ZE key while the probe
carefully and always keep Automatic temperature sensor without touch
this meter within easy reach. Compensation anything, or zeroing is
Power supply: not efficient. make
4x1.5 AAA size (UM-4) battery zeroing can decrease
Dimensions: the effect from the
460×75×35mm 3-1 % symbol 3-5 zero/inc key
temperature and
18.3x3x1.4 inch 3-2 low battery 3-6 pin probe humidity in the air.
Weight: 3-3 max symbol 3-7 testing value 4.2 Hold the instrument with
203g (not including batteries) 3-4 warning light your hand, insert the probes
3-9 hold/dec key
3-8 power/function 3-10 battery cover
key
into the materials straightly. needed code. Please refer to will be returned back the 8.Reference Code Table
The probes are more the table in 8.0 factory setting, just to CODE Hays
deeper, the value is better. say,AL1=13,AL2=18.
4.3 Depress key ,the 5.Warning setting Straw
Cd00
symbol “max”will be 5.1 Depressing key and 6.Replace batteries /General
showed on display, then don't release until “AL2” When battery symbol 555
the max value must be showed on display(it will showed on display, it must Guinea grass
Cd01
stored on display when takes 5 seconds to complete replace the batteries in time. /Clover
measuring. Depress the operation),then press key 3- Slide the batteries cover ,put Soap wort
Cd02
HO key again, this or 3- to choose your suitable the batteries into the hole
function will be canceled. value according to your correctly. Cd03 Wheat Straw
4.4 Choose the suitable need, press key again
code for different hays. back to the operation state. 7.Notes: Please choose the code
Depress the key and 5.2 Setting the “AL1” just the Please take out the batteries if according to your true
not release until the same ways as “AL2”. the instruments without use for conditions, and the default
“CDXX” showed on 5.3 Usually ,“AL2”must larger a long time. code is CD00.
display, then press 3-5 or than “AL1”,if the “AL2” less Put the probe in the air without
3- key to choose your than “AL1” during setting touch anything when zeroing,
process, then the instrument or the zeroing is not efficient.

You might also like