You are on page 1of 7

Field Guide GPT 7505

Based on the GPT 9000M

Occupying a known point

Click Setup
Selecting from List

Then Backsight

Select your occupied point and click OK

Either type in the name of the control point, or


choose from the map view or select properties from
the drop down list Enter your Instrument Ht if needed

GPT7505 2010 Topcon GB Ltd Support 12 August 2010 1/7


t: 01244 669999
e: support@topcon.co.uk
w: http://support.topcon-positioning.eu/
The screen will change, to display the observations.
And choose to either set to BS Azimuth or BS Point

Select your point and click OK If you wish to check the BS setup, then click on the
BS Setup Tab, and then click Check BS

Check the information displayed, if it is correct, align


the telescope crosshairs with the centre of the This will activate the EDM and the instrument will
relevant target and click Set. Wait for the instrument take a reading to the BS and display any associated
to make its confirmation tone. errors in the results section. Note this check will only
work if you selected BS Point, it will not work for BS
Azimuth as the instrument does not have any
coordinate data for the backsight observastions to
check against.

GPT7505 2010 Topcon GB Ltd Support 12 August 2010 2/7


t: 01244 669999
e: support@topcon.co.uk
w: http://support.topcon-positioning.eu/
When you are happy with the Occupied setup, click
Close
And Resection

And you will be returned to the main Icon screen


Give your occupied point a name, and if required
enter instrument and reflector heights, click Next

Enter the name of the 1st known point ,


Resection Setup

From the Main Icon screen click Setup

GPT7505 2010 Topcon GB Ltd Support 12 August 2010 3/7


t: 01244 669999
e: support@topcon.co.uk
w: http://support.topcon-positioning.eu/
Click OK Select the Measure Set tab

Turn the instrument to the target. This gives you the option to either accept, re-
measure or remove any data.
Press the Blue ENT Key on the keypad (don’t click
meas as this does not store the data) If you are happy with the residuals, click Accept.
Note; two known stations is the BARE MINIMUM
and results will rely heavily on their geometry. Three
or more stations will give a better result.

Enter the name of the next point, turn the instrument


to the point, and press the ENT key again

You will be presented with the co-ords of the


occupied position, click OK and coordinates for your
occupied point will be stored as the instrument
makes a sound.

GPT7505 2010 Topcon GB Ltd Support 12 August 2010 4/7


t: 01244 669999
e: support@topcon.co.uk
w: http://support.topcon-positioning.eu/
You are now returned to the resection screen. Click Select method (in this case Points)
Close

And Click the drop down list


Exit Resection? Click YES. Back to the main screen
as can be seen below

Select the desired point and click OK

Setting Out

Click Setout from Main Icon Screen

GPT7505 2010 Topcon GB Ltd Support 12 August 2010 5/7


t: 01244 669999
e: support@topcon.co.uk
w: http://support.topcon-positioning.eu/
Click on Settings Turn the instrument to the required angle using the
dial as a guide and Hz Dist required.

And ensure the settings are as below, click OK


Then select measure as seen below

And then Click Setout


When you are happy with the result click Store

This will show the actual position set out with


differences from the design position, select OK and
the staked point will be stored and the screen will
revert back to the stake out screen.

GPT7505 2010 Topcon GB Ltd Support 12 August 2010 6/7


t: 01244 669999
e: support@topcon.co.uk
w: http://support.topcon-positioning.eu/
Survey Observations
From the Main Icon Screen Click Survey

Click on the Offsets Tab if you want to offset any


measurements.

Then Click Topo

Enter Point number (this will increment after each


measurement), input Code and string if required.
When ready press the ENT button on the keypad
which takes a measurement and records it at the
same time.

To see the observations in a Plan View, Click the


Map Tab, use the Icons on the left to zoom etc.

GPT7505 2010 Topcon GB Ltd Support 12 August 2010 7/7


t: 01244 669999
e: support@topcon.co.uk
w: http://support.topcon-positioning.eu/

You might also like