A AIR AIR LPO LOW PRESSURE OXYGEN
SAUDIARAMCO.
S STEAM
OF
AMMV AMMONIA VAPOR FGH HIGH PRESSURE FUEL GAS SG CLEAN SYNGAS
CONSENT
AS ACID SEWER FGL LOW PRESSURE FUEL GAS SGH HIGH PRESSURE SYNGAS
FLO CHILLED WATER SUPPLY MDEA METHYLDETHANOL AMINE SGL LOW PRESSURE SYNGAS
TTEN
FTT FILTRATE MEG MONO ETHYLENE GLYCOL SO SEAL OIL
WRI
FW FIRE WATER MO MIST OIL SOG SULFUR DIOXIDE GAS
THE
MPC MEDIUM PRESSURE STEAM CONDENSATE SOT SOOT WATER
BBD BOILER BLOW DOWN MPN MEDIUM PRESSURE NITROGEN SOW SOUR WATER
THOUT
BCW BURNER COOLING WATER MPO MEDIUM PRESSURE OXYGEN SPO SLOP OIL
WI
BD BLOW DOWN MPS MEDIUM PRESSURE STEAM SR SEWER (STORM)
NG
BFW BOILER FEED WATER MS MAIN STEAM-VERY HIGH PRESSURE SUPERHEATE SW SALT WATER
DRAWI
BRN BRINE GG GART GAS SWS SANITARY SEWER
S
THI
FROMNED
N NITROGEN TEG TRIETHYLENE GLYCOL
OBTAI
NG NATURAL GAS TG TAIL GAS
BE
CA CAUSTIC HCD HYDROGEN CLOSED DRAIN TW TREATED WATER
PART,SHALL
CAS CAUSTIC SEWER HCL HYDROCHLORIC ACID
CBD COLD BLOWDOWN HFW HIGH PRESSURE BFW OW OILY WATER UA UTILITY AIR REFERENCE DRAWINGS
N
I
FULL,OR
CD CARBON DIOXIDE HHS HIGH HIGH PRESSURE STEAM
N
I
CHR CHILLED WATER RETURN HPCF HIGH PRESSURE COLD FLARE
ON
REPRODUCTI
CHS CHILLED WATER SUPPLY HPF HIGH PRESSURE COLD FLARE VFW VERY HIGH PRESSURE BFW
CNW DIRECT CONTACT CONDENSED WATER HPN HIGH PRESSURE NITROGEN P OIL & OIL PRODUCTS VG VENT GAS
COC CONTINUOSLY OIL CONTAMINATED HPO HIGH PRESSURE OXYGEN PA PROCESS AIR VPC VERY HIGH PRESSURE CONDENSATE
CRH COLD REHEAT STEAM HPS HIGH PRESSURE STEAM PC PROCESS CONDENSATE VPS VERY HIGH PRESSURE STEAM
SAUDIARAMCO.NO
CRO CRUDE OIL HRH HOT REHEAT STEAM PCS POTENTIALLY CONTAMINATED SEWER VR VACUUM RESID
CS CHEMICAL SEWER HSF HIGH SULFUR FUEL OIL PE POND EFFLUENT VS VENT STEAM
CSW CLEAN STORM WATER HSG HYDROGEN SULFIDE GAS PG PURGE GAS VT VESSEL TRIM
OF
CWS COOLING WATER SUPPLY HWR HOT WATER RETURN PS PRESSURIZED SEWER
PROPERTY
HWS HOT WATER SUPPLY PT PUMP TRIMS
PW PROCESS WATER
SOLE
W WATER
THE
D DRAIN WAW WASH WATER
ARE
DCA DICLYCOLAMIN IA NSTRUMENT AIR WBD WET BLOWDOWN
DFW DEAERATOR FEED WATER IPC INTERMEDIATE PRESSURE STEAM CONDENSATE WW WASTE WATER
N
HEREI
DGA DIGLYCOLAMINE DRAWING RESPONSIBILITY:
IPS NTERMEDIATE PRESSURE STEAM R REFRIGERANTS
NED
REVISION VALIDATION
DO DIESEL OIL RG RICH GLYCOL
CONTAI
THIS REVISION NO. 08 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
DSW DISTILLED WATER RL RELIEF LINE
765200-0117-001
DT DUCT TRIMS RLC COLD RELIEF LINE 15C 15 PSIG L. P. CONDENSATE
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
ON
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
DW DRINKING WATER 60C 60 PSIG I. P. CONDENSATE
NFORMATI
RLW WARM RELIEF LINE
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
I
LFW LOW PRESSURE BFW ROW REVERSE OSMOSIS WATER 600C 600 PSIG H. P. CONDENSATE
THE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
LG LEAN GLYCOL 15S 15 PSIG L. P. STEAM CONSTRUCTION UNTIL CERTIFIED AND DATED
RP REFRIGERANT PROPANE
AND
LME LEAN METHANOL RSG RAW SYNGAS 60S 60 PSIG I. P. STEAM
DRAWING TYPE
LETTER DESIGNATION
NG
LO LUBE OIL RW RAW WATER 150S 150 PSIG M. P. STEAM STD
DRAWI
E EXHAUST STEAM LOX LIQUID OXYGEN 250S 250 PSIG M. P. STEAM FOR LINES NUMBERS
EIA EMERGENCY INSTRUMENT AIR LPC LOW PRESSURE STEAM CONDENSATE 600S 600 PSIG H. P. STEAM
S
THI
EXG EXHAUST / FLUE / STACK GAS LPF LOW PRESSURE FLARE STD. DWG. SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
LPG LIQUEFIED PETROLEUM GAS
VECTOR CADD-05