Professional Documents
Culture Documents
,LTD
Tel: 0086 18250621073
Contact person: Summer
Fax:0086 592 6224 633
2、So ,we suggest DCZK 30-2000 type ,max loading capacity 30KG,Lifting
height is up to 1700mm;
1
Vacuum tube lifter Parameter
2
3
DCZK 30-1700 type components as bellow :
Item Qua
No. Component Name Model Number ntity
1 Lifting air tube HS 140 / 4000 1
2 Vacuum blower 380V,50 Hz,3kW,135m³/h 1
3 Sucker Cup SFB230X380 1
DK 200,Groove ball bearing and integrated
1
4 rotating joint one-way valve
5 plastic connector SK-50 1
6 suction head 200 1
7 Lift control lever SGK Swing rod and integrated valve unit. 1
9 filter standard SFS 1
10 The vacuum tube Φ50 mm 10m
11 Cantilever guide Length 3000mm 1
12 Jib crane Height 4900mm 1
4
四、方案模拟分析
5
How to use DCZK 30-1700 type vacuum tube lifter ?
(1) Operation of manipulating handle when lifting goods:
(1) Position 1 (Balancing position): the system is in a state of balance, which can
not be lifted or put down the goods.
(2) Position 2 (lifting limited position): the pull rod is pulled up at this time, the
valve intake of the control room is completely sealed, and the goods rise rapidly.
The position of the pull rod in the position of 1 and 2 determines the degree of
sealing, thus determining the speed of the lifting. The closer the pull rod closer
to position 2, the faster the lifting speed;
6
(3) Position 3 (falling limit position): at this point, the air inlet of the control
chamber opens when the rod is pressed down, so that the vacuum suction is less
than the weight of the goods, and the goods are descended. When the goods are
placed on the worktable or the ground, the goods can be put down and the
suckers are separated from the goods.
When the load is not absorbed, the adjustment of this knob can adjust the natural
length of the lifting pipe when no load is loaded.
7
Check whether the filter is blocked or damaged or not to be cleaned and
damaged must be replaced.
(2)Weekly maintenance:
(1) check adsorption capacity: start the vacuum pump / fan, be sucked at about
10kg smooth and dense goods, goods will be raised, and then close the vacuum
pump / air blower, the operating handle is pressed, the goods should slow down,
if the goods decreased rapidly, please check the system or contact with me;
(2) check whether the filter is blocked or damaged.
(3) check whether the suction cup is damaged or not;
(4) check whether the telescopic trachea is damaged or not;
(3)Quarterly Maintenance:
(1) check whether the suspension hook and its connector of the telescopic
trachea are damaged, if there is, the system can not be used, please contact our
company.
(2) check whether the nut and bolt connection at the hook and the cantilever are
loosened. If there is, it will tighten it.
(3) check whether the vacuum trachea is damaged or atrophied.
Summer