You are on page 1of 28

Method Collection

Recommended
Moisture Methods

Precise
Practical
Fast

Food Industry
Moisture Methods
2 METTLER TOLEDO Method Collection for Food Industry
Content

Determining Moisture Content in the Food Industry .................. 4


How to Read This Brochure ........................................................... 5

Moisture Determination Methods for

Baking powder .................................................................................. 6


Biscuit dough .................................................................................... 7
Biscuit, Petit Beurre .......................................................................... 8
Butter .................................................................................................. 9
Chips, paprika .................................................................................. 10
Cocoa powder .................................................................................. 11
Coffee, ground .................................................................................. 12
Condensed milk ............................................................................... 13
Corn meal, fine ................................................................................. 14
Emmentaler ....................................................................................... 15
Green tea ........................................................................................... 16
Hazelnuts, ground ............................................................................ 17
Ketchup .............................................................................................. 18
Gelatine, edible ................................................................................. 19
Milk powder ....................................................................................... 20
Disclaimer
Oat flakes ........................................................................................... 21 We carefully tested these methods with
Orange juice ...................................................................................... 22 a METTLER TOLEDO Halogen Moisture
Analyzer. However, you should still per-
Pasta ................................................................................................... 23 sonally test the information for its suita-
bility to your intended purpose. Because
Pepper, ground ................................................................................. 24 the use and transfer of an application
Tomato juice ...................................................................................... 25 example are beyond our control, we
cannot accept responsibility for this. The
White flour ......................................................................................... 26 general safety rules and precautions of
the manufacturer (e.g. for chemicals or
Yogurt ................................................................................................. 27 solvents) must be observed.

METTLER TOLEDO Method Collection for Food Industry 3


Moisture determination with an HC103 Moisture Analyzer

Determining Moisture Content in the Food Industry


Moisture analysis plays a vital role in all areas of the food industry, from goods-in inspections, through quality control,
production and storage, to the development of new products. In nearly all cases, the prepared ingredients have
an optimum moisture content, providing the best possible taste, consistency, appearance and shelf-life. Moisture
determination therefore ensures consistent product quality. The food industry is under constant pressure to keep
costs at a minimum, whilst producing enormous quantities and maintaining uniform quality. The determination of the
moisture content therefore needs to be conducted in a reliable way, and often at speed, so that interventions in the
production process can be made quickly, to avoid interruptions or even production stops.

There are several types of methods available for analyzing the moisture content of foodstuffs, one of them being
thermogravimetric measurements, such as oven drying, halogen/IR drying and microwave drying.

Thermogravimetric Methods for Moisture Analysis – Loss on Drying


To measure moisture content, typically loss on drying (LOD) is performed using a drying oven as the reference
method, but this method usually takes hours until results are available. The oven method is a tedious procedure,
involving many manual steps. Much faster determination of moisture content can be achieved using alternative
methods, such as Halogen Moisture Analysis, which is easy to use and gives a direct result in a fraction of the time.
The Halogen Moisture Analyzer (HMA), similar to the drying oven, operates on the principle of LOD, but moisture
determination normally takes only 5 to 15 minutes, compared to 2 to 4 hours using a drying oven. The other key
benefit of HMA is ease of operation, delivering a direct measurement result with no calculations necessary.

Moisture Determination with a Moisture Analyzer


The halogen technology is key to fast and precise results with a moisture analyzer. All moisture analyzers from
METTLER TOLEDO are equipped with this innovative heating technology. The results of moisture analyzers must
be compared to the reference value (drying oven), in order to develop the proper method parameters for the HMA.
METTLER TOLEDO has established an extensive library of validated measurement methods for over 100 food products.
This moisture method collection features 20 out of them.

4 METTLER TOLEDO Method Collection for Food Industry


How to Read This Brochure
For every sample in this brochure, the preparation and procedure and the corresponding method parameters are
provided for both the drying oven and the Halogen Moisture Analyzer (HMA).

Sample measured on both


HMA and Drying Oven
Description of all relevant
method parameters

Detailed information
on how to prepare
your sample to ensure
meaningful analysis

The measurement performance of the HMA is illustrated with a diagram for each substance, showing the
corresponding drying curve. The drying curve shows the progress of the moisture content determination over time,
providing useful insight into the drying dynamics of a given substance.
Drying curve over time, slope
shows the speed of LOD and
Exemplary Drying Curve
defines the switch-off criterion
Automatic calculation and
display of the chosen unit

Monitoring of the process over time

The mean and the repeatability (SD, n=6) of the results using both techniques are displayed in an easy-to-read manner.

Mean of the result,


showing comparability to
the drying oven

Summary of the main


information of the
measurements

To learn more about proper moisture analysis, please consult our:

Moisture e-Learning
Moisture Guide
} www.mt.com/moisture-elearning
} www.mt.com/moisture-guide

Tips & Tricks Poster


} www.mt.com/moisture-tips-poster
METTLER TOLEDO Method Collection for Food Industry 5
Moisture Determination Method for
Baking powder

Description of sample
Powder

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 125 °C 103 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 2g 5g
Sample preparation Stir sample, use spatula to put Dry weighing container with cover
and procedure the sample on the pan then in oven (103 °C, 1 h), allow to cool
distribute it evenly by gently in desiccator, weigh. Stir sample,
shaking the pan add to container, weigh.
Dry in oven (5 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

3.50

3.00

2.50

2.00
%MC

1.50

1.00

0.50

0.00
0 60 120 180
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 3.34 %MC 3.29 %MC
Standard deviation (SD) 0.07 0.09
Measurement duration (mean) 3 min 300 min

6 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Biscuit dough

Description of sample
Milk-biscuit dough

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 135 °C 103 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 7g 5g
Sample preparation Press sample in batter spreader Dry weighing container with cover in oven
and procedure into a circular, thin sheet. Place (103 °C, 1 h), allow to cool in desiccator,
as one on sample pan weigh. Knead sample to homogenous
mixture. Add to container, weigh.
Dry in oven (4 h), allow to cool down to
room temperature in desiccator, weigh.
Dry sample one more time in oven (1 h,),
cool in desiccator, weigh

Exemplary Drying Curve

25.00

20.00

15.00
%MC

10.00

5.00

0.00
0 180 360 540 720 900 1080 1260 1440 1620 1800
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 19.81 %MC 19.73 %MC
Standard deviation (SD) 0.09 0.24
Measurement duration (mean) 26 min 240 min

METTLER TOLEDO Method Collection for Food Industry 7


Moisture Determination Method for
Biscuit, Petit Beurre

Description of sample
Dry biscuit

Reference method
Oven

Method parameters:
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 120 °C 103 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 3g 5g
Sample preparation Grind sample in mortar, use Dry weighing container with cover in oven
and procedure spatula to put the sample on the (103 °C, 1 h), allow to cool in desiccator,
pan then distribute it evenly by weigh. Grind sample in mortar, stir well,
gently shaking the pan add to container, weigh.
Dry in oven (4 h), allow to cool down to
room temperature in desiccator, weigh.
Dry sample again in oven (1 h), cool in
desiccator, weigh

Exemplary Drying Curve


2.50

2.00

1.50
%MC

1.00

0.50

0.00
0 60 120 180 240 300
Time [s]

Measurement results:
Halogen Moisture Analyzer Drying Oven
Result (mean) 2.32 %MC 2.30 %MC
Standard deviation (SD) 0.04 0.32
Measurement duration (mean) 4 min 270 min

8 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Butter

Description of sample
Butter

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 110 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 3g 2g
Sample preparation Allow sample to come to room Dry metal pan (approx. 5 cm) with
and procedure temperature, distribute evenly on cover in the oven (103 °C, 1 h), allow
the sample pan to cool in desiccator, weigh. Allow
sample to come to room temperature,
stir well, add to pan, weigh.
Dry in oven (4 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

16.00
14.00
12.00
10.00
%MC

8.00
6.00
4.00
2.00
0.00
0 60 120 180 240 300 360 420 480 540 600
Time [s]

Measurement results Halogen Moisture Analyzer Drying Oven


Result (mean) 15.11 %MC 15.13 %MC
Standard deviation (SD) 0.09 0.07
Measurement duration (mean) 9 min 240 min

METTLER TOLEDO Method Collection for Food Industry 9


Moisture Determination Method for
Chips, paprika

Description of sample
Potato chips, salted and flavored with paprika

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 122 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 5g 5g
Sample preparation Grind sample in mortar, use Dry weighing container with cover in
and procedure spatula to distribute evenly on oven (102 °C, 1 h), allow to cool in des-
the sample pan iccator, weigh. Grind sample in mortar,
stir well, add to container, weigh.
Dry in oven (4 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
0 60 120 180 240 300 360 420 480 540 600
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 1.38 %MC 1.42 %MC
Standard deviation (SD) 0.04 0.01
Measurement duration (mean) 9 min 240 min

10 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Cocoa powder

Description of sample
Powder

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 100 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 2g 5g
Sample preparation Stir sample, use spatula to put Dry weighing container with cover in
and procedure the sample on the pan then oven (102 °C, 1 h), allow to cool in
distribute it evenly by gently desiccator, weigh. Stir sample, add to
shaking the pan container, weigh.
Dry in oven (4 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

2.50

2.00

1.50
%MC

1.00

0.50

0.00
0 60 120 180 240 300
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 3.05 %MC 3.02 %MC
Standard deviation (SD) 0.05 <0.01
Measurement duration (mean) 4 min 240 min

METTLER TOLEDO Method Collection for Food Industry 11


Moisture Determination Method for
Coffee, ground

Description of sample
Powder of ground coffee beans

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 120 °C 103 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 3g 5g
Sample preparation Stir sample, use spatula to dis- Dry weighing container with cover in
and procedure tribute evenly on the sample pan oven (103 °C, 1 h), allow to cool in
desiccator, weigh. Stir sample, add to
container, weigh.
Dry in oven (5 h), allow to cool down to
room temperature in desiccator, weigh.
Dry sample again in oven (1 h), cool in
desiccator, weigh

Exemplary Drying Curve

5.00

4.00

3.00
%MC

2.00

1.00

0.00
0 60 120 180 240 300
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 4.42 %MC 4.46 %MC
Standard deviation (SD) 0.03 0.01
Measurement duration (mean) 5 min 360 min

12 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Condensed milk

Description of sample
Viscous liquid, non-sweetened

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 140 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 2g 6g
Sample preparation Stir sample, apply evenly in Dry metal pan with 20 g of sand, glass
and procedure between two glass fiber filters stirrer and cover in the oven (102 °C,
using a pipette 1 h), allow to cool in desiccator, weigh.
Stir sample, add to pan, weigh, allow to
evaporate in oven for 30 min at 90 °C,
add 5 ml of water, mix.
Dry in oven (2 h), allow to cool down to
room temperature in desiccator, weigh.
Dry sample two more times in oven (1 h,
each time), cool in desiccator, weigh

Exemplary Drying Curve

80.00

60.00
%MC

40.00

20.00

0.00
0 60 120 180 240 300 360 420 480
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 74.60 %MC 74.56 %MC
Standard deviation (SD) 0.17 0.08
Measurement duration (mean) 8 min 240 min

METTLER TOLEDO Method Collection for Food Industry 13


Moisture Determination Method for
Corn meal, fine

Description of sample
Granulate

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 160 °C 130 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 5g 5.5 g
Sample preparation Stir sample, use spatula to put Dry weighing container with cover in
and procedure the sample on the pan then dis- oven (130 °C, 1 h), allow to cool in
tribute it evenly by gently shaking desiccator, weigh. Stir sample well, add
the pan to container, weigh.
Dry in oven (1.5 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

16.00
14.00
12.00
10.00
%MC

8.00
6.00
4.00
2.00
0.00
0 120 240 360 480 600 720 840
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 14.54 %MC 14.56 %MC
Standard deviation (SD) 0.03 <0.01
Measurement duration (mean) 13 min 90 min

14 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Cheese, Emmental

Description of sample
Hard cheese with >35% fat

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 110 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 3g 2g
Sample preparation Grate sample, stir, use spatula Dry weighing container with 10 g of sand,
and procedure to distribute evenly on a glass glass stirrer and cover in the oven (102 °C,
fiber filter 1 h), weigh. Grate sample, stir well, add to
container, weigh, grind with sand.
Dry in oven (4 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

35.00

30.00

25.00

20.00
%MC

15.00

10.00

5.00

0.00
0 240 480 720 960 1200 1440 1680
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 31.48 %MC 31.99 %MC
Standard deviation (SD) 0.18 0.03
Measurement duration (mean) 26 min 240 min

METTLER TOLEDO Method Collection for Food Industry 15


Moisture Determination Method for
Green tea

Description of sample
Loose tea

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 125 °C 103 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 2.5 g 5g
Sample preparation Stir sample, use spatula to dis- Dry weighing container with cover in
and procedure tribute evenly on the sample pan oven (102 °C, 1 h), allow to cool in
desiccator, weigh. Stir sample, add to
container, weigh. Dry in oven (16 h),
allow to cool down to room temperature
in desiccator, weigh

Exemplary Drying Curve

8.00
7.00
6.00
5.00
%MC

4.00
3.00
2.00
1.00
0.00
0 60 120 180 240 300 360 420 480 540
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 7.01 %MC 7.09 %MC
Standard deviation (SD) 0.08 0.05
Measurement duration (mean) 8 min 960 min

16 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Hazelnuts, ground

Description of sample
Ground hazelnuts, brownish powder

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 130 °C 103 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 4g 5g
Sample preparation Stir sample, use spatula to put Dry weighing container with cover in oven
and procedure the sample on the pan then (103°C, 1h), allow to cool in desiccator,
distribute it evenly by gently weigh. Stir sample, add to container, weigh.
shaking the pan Dry in oven (2 h), allow to cool down to
room temperature in desiccator, weigh. Dry
sample two more times in oven (1 h, each
time), cool in desiccator, weigh

Exemplary Drying Curve

6.00

5.00

4.00
%MC

3.00

2.00

1.00

0.00
0 60 120 180 240 300 360
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 5.27 %MC 5.27 %MC
Standard deviation (SD) 0.08 0.07
Measurement duration (mean) 6 min 240 min

METTLER TOLEDO Method Collection for Food Industry 17


Moisture Determination Method for
Ketchup

Description of sample
Ketchup

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 125 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 4g 2g
Sample preparation Stir sample, use spatula to distrib- Dry metal pan with 25 g sand, glass stirrer
and procedure ute evenly on a glass fiber filter and cover in the oven (102 °C, 1 h), allow
to cool in desiccator, weigh. Stir sample,
add to pan, weigh, mix with sand.
Dry in oven (4 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

80.00

60.00
%MC

40.00

20.00

0.00
0 240 480 720 960 1200 1440 1680
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 69.40 %MC 69.29 %MC
Standard deviation (SD) 0.06 0.06
Measurement duration (mean) 24 min 240 min

18 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Gelatine, edible

Description of sample
Granulate

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 145 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 6g 5g
Sample preparation Stir sample, use spatula to put Dry weighing container with cover in
and procedure the sample on the pan then oven (103 °C, 1 h), allow to cool in
distribute it evenly by gently desiccator, weigh. Stir sample, add to
shaking the pan container, weigh.
Dry in oven (2 h), allow to cool down to
room temperature in desiccator, weigh.
Dry sample three more times in oven (1 h,
each time), cool in desiccator, weigh

Exemplary Drying Curve

10.00

8.00

6.00
%MC

4.00

2.00

0.00
0 60 120 180 240 300 360 420 480
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 9.15 %MC 9.01 %MC
Standard deviation (SD) 0.09 0.14
Measurement duration (mean) 7 min 300 min

METTLER TOLEDO Method Collection for Food Industry 19


Moisture Determination Method for
Milk powder

Description of sample
Powder of milk with 2.7% milk fat

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 110 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 3g 2g
Sample preparation Stir sample, use spatula to put Dry weighing container with cover in
and procedure the sample on the pan then oven (102 °C, 1 h), allow to cool in
distribute it evenly by gently desiccator, weigh. Stir sample, add to
shaking the pan container, weigh. Dry in oven (2 h),
allow to cool down to room temperature
in desiccator, weigh. Dry sample two
more times in oven (1 h, each time),
cool in desiccator, weigh

Exemplary Drying Curve

5.00

4.00

3.00
%MC

2.00

1.00

0.00
0 60 120 180 240 300 360 420 480
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 4.61 %MC 4.67 %MC
Standard deviation (SD) 0.10 0.02
Measurement duration (mean) 7 min 240 min

20 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Oat flakes

Description of sample
Flakes

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 150 °C 131 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 4g 5g
Sample preparation Grind sample, use spatula to Dry weighing container with cover in oven
and procedure put the sample on the pan then (131 °C, 1 h), allow to cool in desiccator,
distribute it evenly by gently weigh. Grind sample, stir well, add to
shaking the pan container, weigh.
Dry in oven (1.5 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

12.00

10.00

8.00
%MC

6.00

4.00

2.00

0.00
0 60 120 180 240 300 360 420
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 10.96 %MC 10.91 %MC
Standard deviation (SD) 0.04 0.01
Measurement duration (mean) 6 min 90 min

METTLER TOLEDO Method Collection for Food Industry 21


Moisture Determination Method for
Orange juice

Description of sample
Made of 100% oranges, from concentrate

Reference method
Oven

Method parameters
Rapid Not applicable
Drying program 140 °C 103 °C
Drying temperature 3 (1 mg/50 s) Not applicable
Switch-off criterion 2g 10 g
Sample weight Stir sample, apply evenly to Dry metal pan (approx. 8 cm) with 10 g
glass fiber filter using a pipette sand, glass stirrer and cover in the oven
(103 °C), allow to cool in desiccator,
weigh. Stir sample, add to pan using a
pipette, weigh, mix with sand, evaporate
in water bath for 30 min.
Dry in oven (3 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

100.00

80.00

60.00
%MC

40.00

20.00

0.00
0 60 120 180 240 300 360 420
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 89.40 %MC 89.23 %MC
Standard deviation (SD) 0.04 0.06
Measurement duration (mean) 6 min 180 min

22 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Pasta

Description of sample
Dried pasta made of durum wheat

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program 145 °C 130 °C
Drying temperature 3 (1 mg/50 s) Not applicable
Switch-off criterion 4g 5.5 g
Sample weight Grind sample, use spatula to Dry weighing container with cover in oven
put the sample on the pan then (131 °C, 1 h),
distribute it evenly by gently allow to cool in desiccator, weigh. Grind
shaking the pan sample, stir well, add to container, weigh.
Dry in oven (1.5 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

12.00

10.00

8.00
%MC

6.00

4.00

2.00

0.00
0 120 240 360 480 600 720 840 960
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 10.90 %MC 10.90 %MC
Standard deviation (SD) 0.10 0.03
Measurement duration (mean) 14 min 90 min

METTLER TOLEDO Method Collection for Food Industry 23


Moisture Determination Method for
Pepper, ground

Description of sample
Granulate, fine-grained

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 135 °C 102 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 2g 5g
Sample preparation Stir sample, use spatula to put Dry weighing container with cover in
and procedure the sample on the pan then oven (102 °C, 1 h), allow to cool in
distribute it evenly by gently desiccator, weigh. Stir sample, add to
shaking the pan container, weigh. Dry in oven (2 h),
allow to cool down to room temperature
in desiccator, weigh. Dry sample two
more times in oven (1 h, each time),
cool in desiccator, weigh

Exemplary Drying Curve

12.00

10.00

8.00
%MC

6.00

4.00

2.00

0.00
0 60 120 180 240 300
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 10.82 %MC 10.70 %MC
Standard deviation (SD) 0.12 0.05
Measurement duration (mean) 5 min 240 min

24 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Tomato juice

Description of sample
Liquid, homogeneous

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Rapid Not applicable
Drying temperature 130 °C 103 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 3g 4g
Sample preparation Stir sample, apply evenly to Dry metal pan (approx. 8 cm) with 10 g
and procedure glass fiber filter using a pipette sand, glass stirrer and cover in the oven
(103 °C, 30 min), allow to cool in des-
iccator, weigh. Stir sample, add to pan
using a pipette, weigh, mix with sand,
evaporate in water bath for 30 min.
Dry in oven (3 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

100.00

80.00

60.00
%MC

40.00

20.00

0.00
0 60 120 180 240 300 360 420 480 540 600
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 95.22 %MC 95.32 %MC
Standard deviation (SD) 0.05 0.04
Measurement duration (mean) 8 min 180 min

METTLER TOLEDO Method Collection for Food Industry 25


Moisture Determination Method for
White flour

Description of sample
Powder

Reference method
Oven

Method parameters
Halogen Moisture Analyzer Drying Oven
Drying program Standard Not applicable
Drying temperature 140 °C 130 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 4g 5g
Sample preparation Stir sample, use spatula to dis- Dry weighing container with cover in
and procedure tribute evenly on the sample pan oven (130 °C, 1 h), allow to cool in
desiccator, weigh. Stir sample well, add
to container, weigh.
Dry in oven (2 h), allow to cool down to
room temperature in desiccator, weigh

Exemplary Drying Curve

12.00

10.00

8.00
%MC

6.00

4.00

2.00

0.00
0 60 120 180 240 300 360 420 480
Time [s]

Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 11.33 %MC 11.60 %MC
Standard deviation (SD) 0.06 0.09
Measurement duration (mean) 7 min 120 min

26 METTLER TOLEDO Method Collection for Food Industry


Moisture Determination Method for
Yogurt

Description of sample

Yogurt (unskimmed milk)

Reference method
Oven

Method parameters Halogen Moisture Analyzer Drying Oven


Drying program Rapid Not applicable
Drying temperature 105 °C 87 °C
Switch-off criterion 3 (1 mg/50 s) Not applicable
Sample weight 3g 2.5 g
Sample preparation Stir sample, use spatula to dis- Dry metal pan with 25 g sand, glass stirrer
and procedure tribute evenly on the sample pan and cover in the oven (103 °C, 1 h), allow
to cool in desiccator, weigh. Stir sample,
add to pan, weigh, mix with sand.
Dry in oven (2 h), allow to cool down to
room temperature in desiccator, weigh.
Dry sample again in oven (1 h), cool in
desiccator, weigh

Exemplary Drying Curve

100.00

80.00

60.00
%MC

40.00

20.00

0.00
0 120 240 360 480 600 720 840 960
Time [s]
Measurement results
Halogen Moisture Analyzer Drying Oven
Result (mean) 87.41 %MC 87.50 %MC
Standard deviation (SD) 0.10 0.10
Measurement duration (mean) 14 min 180 min

METTLER TOLEDO Method Collection for Food Industry 27


Benefit from our Moisture Expertise

With decades of experience in laboratory weighing and halogen moisture analysis,


METTLER TOLEDO offers a wide range of know-how and tools. Make the most of our
expertise to enhance your moisture knowledge and ensure you benefit from all the power
that your moisture analyzer offers. Check out the documentation on our internet site.

E-Learning: Proper Moisture Analysis


Our e-learning course gives you an overview
of the most important moisture determination
techniques. It also explains in detail how to ac-
curately determine the moisture content of your
sample using a moisture analyzer.
} www.mt.com/moisture-elearning

White Paper:
Moisture Analyzer versus drying oven
The White Paper "Drying Oven vs. Halogen
Moisture Analyzer (HMA)" explains scientifi-
cally how the drying oven method can easily
be replaced by rapid, easy-to-use halogen
moisture analysis.
} www.mt.com/moisture-vs-oven

White Paper: Moisture Analysis Routine Testing


This white paper describes the influences and sour-
ces of error which may be present when conducting
moisture analyses. It discusses the routine tests
which are necessary to ensure consistent, reliable
determination of the moisture content and correct
functioning of the instrument. mine the moisture
content of your sample using a moisture analyzer.
} www.mt.com/moisture-routinetesting

Visit our homepage for even more knowhow-tools:

www.mt.com/moisture-routine-testing
For more information

Mettler-Toledo GmbH
Laboratory and Weighing Technologies
CH-8606 Greifensee, Switzerland
Tel. +41 44 944 22 11
Fax +41 44 944 30 60

Subject to technical changes


© 01/2016 Mettler-Toledo GmbH
30315394
Global MarCom Switzerland, 1846 RK

You might also like