Professional Documents
Culture Documents
Protocolo Pruebas Fabrica - ACSR Bluejay
Protocolo Pruebas Fabrica - ACSR Bluejay
Specification ACSR-Bluejay
Drum No. 1
Tester: Checker:
3 Conductor tests
3.1 Surface condition ASTM B232 PASS
3.97,3.97
1.1 Diameter 3.995mm±0.04mm 3.97,3.97 PASS
3.97
190,193
≥157MPa
1.2 Breaking strength test 194,192 PASS
(165MPa×95%)
191
2.2%,2.0%
Min elongation at 250
1.4 ≥2.0% 2.2%,2.0% PASS
mm
2.0%
0.027721
0.027715
Resistivity for Single
1.5 ≤0.028172Ω.mm2/m 0.027715 PASS
Wire at 20℃
0.027733
0.027545
Tensile stress at 1% of
2.3 ≥1280MPa 1393 PASS
extension for steel
The steel wire shall be wrapped
round a mandrel of diameter equal
2.4 Wrapping test to two times the wire diameter to OK PASS
form a close helix of eight turns. The
wire shall not break.
3 Conductor Tests
Direction of lay
3.6 Right-hand Right-hand PASS
(outer layer)