ARCHITECTURAL Republic of the Philippines


Department of Public Works
Transportation and Communication
OFFICE OF THE BUILDING OFFICIAL
CS PERSPECTIVE
VICINITY MAP
SITE DEVELOPMENT PLAN

A-1 FLOOR PLAN


District / City / Municipality
REFLECTED CEILING PLAN
A-2 ROOF PLAN
SCHEDULE OF DOORS AND WINDOWS

FRONT ELEVATION
LEFT ELEVATION
REAR ELEVATION
A-3 RIGHT ELEVATION
SECTION THRU A
SECTION THRU B

LAND USE AND ZONING

STRUCTURAL

FOUNDATION PLAN
S-1 ROOF FRAMING PLAN
W-F DETAIL
C-F DETAIL
ROOF SECTION DETAIL

LINE AND GRADE

ELECTRICAL

POWER LAYOUT
LIGHTING LAYOUT
VICINITY MAP
E-1 SCHEDULE OF LOAD
RISER DIAGRAM
GENERAL NOTES
LEGEND
ARCHITECTURAL

SANITARY AND PLUMBING

PLUMBING LAYOUT
SANITARY LAYOUT
P-1 CATCH BASIN DETAIL
SEPTIC TANK DETAIL

PLUMBING ISOMETRIC DIAGRAM


SANITARY ISOMETRIC DIAGRAM
P-2 GENERAL NOTES
STRUCTURAL
LEGEND

SANITARY

2
CS
VICINITY
SCALE
MAP
NTS
3
CS
SITE
SCALE
DEVELOPMENT PLAN
NTS

ARCHITECT - OF - RECORD PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

CS
DATE 01/23/2021
PROPOSED ADMIN BUILDING FACILITY CAD BY GFMP

AR. JOHN LAWRENCE S. TING, UAP PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9266 Section 33
DESIGNER NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
B
A

W
4

D
W W W
3 1 1 1

W
1
W
4

W
2

A W
4
A

W
3

D D D
1 2 2

W W
1 1

1
A1 SCALE
GROUND FLOOR PLAN
1:100M

ARCHITECT - OF - RECORD PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

A1
DATE 01/23/2021
PROPOSED ADMIN BUILDING FACILITY CAD BY GFMP

AR. JOHN LAWRENCE S. TING, UAP PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9266 Section 33
DESIGNER NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
B
A

800 900 600

A
A

2100

2100

2100
DOOR TYPE : SOLID DOOR DOOR TYPE : SOLID DOOR DOOR TYPE : FLUSH DOOR
D D D
SET REQ'D: ONE (1) SET REQ'D: TWO (2) SET REQ'D: ONE (1)
1 LOCATION: ADMIN & OPERATION 2 LOCATION: CONFERENCE ROOM & 3 LOCATION: COMMON TOILET
STORAGE

1 REFLECTED CEILING PLAN


A1 SCALE 1:100M
1900 1000
1200 1800

600
750

750
1200

1200

1200
450

450

1500
900

850

865
WINDOW TYPE : CASEMENT WINDOW WINDOW TYPE : 2 PANEL FIXED AND WINDOW TYPE : FIXED AND SLIDING WINDOW TYPE : 3 PANEL AWNING
W W SLIDING WINDOW W WINDOW W WINDOW
SET REQ'D : SIX (6)
1 2 SET REQ'D : ONE (1) 3 SET REQ'D : ONE (1) 4 SET REQ'D : TWO (2
LOCATION : ADMIN
LOCATION : CASHIER LOCATION : CREDIT LOCATION : STORAGE

3 SCHEDULE OF DOOR AND WINDOWS


A3 SCALE 1:50M

2 ROOF PLAN
A3 SCALE 1:150M

ARCHITECT - OF - RECORD PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

A2
DATE 01/23/2021
PROPOSED ADMIN BUILDING FACILITY CAD BY GFMP

AR. JOHN LAWRENCE S. TING, UAP PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9266 Section 33
DESIGNER NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
GAUGE # 26 RIB TYPE ROOF GAUGE # 26 RIB TYPE ROOF

1 FRONT ELEVATION
A1 SCALE 1:100M
2 LEFT ELEVATION
A1 SCALE 1:100M

GAUGE # 26 RIB TYPE ROOF


GAUGE # 26 RIB TYPE ROOF

3 REAR ELEVATION
A1 SCALE 1:100M
4 RIGHT ELEVATION
A1 SCALE 1:100M

5
A1 SCALE
SECTION THRU1:100M
A 6
A1 SCALE
SECTION THRU1:100M
B

ARCHITECT - OF - RECORD PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

A3
DATE 01/23/2021
PROPOSED ADMIN BUILDING FACILITY CAD BY GFMP

AR. JOHN LAWRENCE S. TING, UAP PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9266 Section 33
DESIGNER NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
600
F.F.L.
150 mm THK.

VERIFY
CONCRETE SLAB
N.G.L.
S40 G.I. PIPE
3 - 12 mm

VARIES
600
7- 12mm REBARS CONTINUOUS BARS
SPACED @ 100MM,
TB-1 TB-1 TB-1 TB-1 TB-1 O.C.B.W

10 mm TRANSVERSE

200
200 BARS @ 300 mm O.C. B.W.
TB-1

TB-1

TB-1

TB-1

TB-1

TB-1
F.F.L.
TB-1 TB-1 TB-1
3 WALL FOOTING DETAIL

VERIFY
TB-1 TB-1 S40 G.I. PIPE S2 SCALE 1:30M
N.G.L.
100 mm THK

600
4"THK CONCRETE SLAB WITH
12MM Ø REINFORCEMENT BARS
CONCRETE SLAB
@ 400MM SPACING
TB-1

TB-1

TB-1

TB-1

TB-1

TB-1
100 mm THK GRAVEL

7- 12mm REBARS
SPACED @ 100MM,
O.C.B.W

300
TB-1 TB-1 TB-1 TB-1
TB-1

TB-1

TB-1

TB-1

TB-1

TB-1
TB-1 TB-1 TB-1 TB-1 TB-1
4 COLUMN FOOTING DETAILS
S2 SCALE 1:30M

1 FOUNDATION PLAN
S1 SCALE 1:100M

MAIN TRUSS
2863 4063
1.2mm x 50mm x 75mm GAUGE # 26 RIB TYPE ROOF
C-PURLINS

1.2mm x 50mm x 75mm


C-CHANNEL
50mm x 100mm
C-CHANNEL RAFTERS
319 1300
CEILING

S40 G.I. PIPE

1.2mm x 50mm x 75m


C-CHANNEL

5 ROOF SECTION DETAIL


S2 SCALE 1:75M

50mm x 100m
C-CHANNEL RAFTERS
2 ROOF FRAMING LAYOUT
S1 SCALE 1:100M
1.2mm x 50mm x 75m
C-PURLINS SPACED
@600mm O.C.B.W.

ARCHITECT - OF - RECORD ENGINEER PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

S1
DATE 01/23/2021
PROPOSED ADMIN BLDG FACILITY CAD BY GFMP
AR. JOHN LAWRENCE S. TING, UAP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9 266 Section 33 Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
DESIGNER NAME & SIGNATURE NAME & SIGNATURE
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
1
E1
POWER
SCALE
LAYOUT PLAN
1:100M

ACU
ACU ACU

ACU

2
E1
LIGHTING
SCALE
LAYOUT PLAN
1:100M

ARCHITECT - OF - RECORD PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

E1
DATE 01/23/2021
PROPOSED ADMIN BLDG FACILITY CAD BY GFMP
AR. JOHN LAWRENCE S. TING, UAP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9 266 Section 33 Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
DESIGNER NAME & SIGNATURE P.E.E. NAME & SIGNATURE
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
GENERAL NOTES
Ckt Size of
Load Description WATTS AMPS Volts AT Size of Wire 1. THE ELECTRICAL INSTALLATION HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISIONS OF THE
No. Conduits
LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE LOCAL RULES AND REGULATIONS AND THE
1 COMMON AREAS & GENSET ROOM 2300 10.00 230 20AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 20mm Ø Conduit REQUIREMENTS OF THE UTILITY COMPANY.
2 PP-WH 8466 36.81 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit 2. ALL ELECTRICAL WORKS HEREIN SHALL BE EXECUTED BY EXPERIENCED MEN UNDER THE SUPERVISION
OF A DULY REGISTERED ELECTRICAL ENGINEER. WORKS SHALL BE NEATLY PLACED, SECURELY
3 PP-SH 6216 27.03 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit FASTENED AND PROPERLY FINISHED.
4 PP-SQ 2662 11.57 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit 3. SERVICE ENTRANCE SHALL BE SINGLE - PHASE, TWO - WIRE PLUS GROUND, 230V, 60Hz.
4. MATERIALS SHALL BE NEW AND SHALL CONFORM WITH THE PROVISIONS OF THE UNDERWRITERS
5 PP-PV 615 2.67 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit
LABORATORIES INC., IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED.
6 PP-AD 12018 52.25 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit 5. ALL CONDUITS EMBEDDED IN CONCRETE SHALL BE PVC, WHILE CONDUITS ABOVE CEILING OR WOOD
PARTITION SHALL BE ELECTRIC METAL TUBING.(EMT)
7 SPARE 40AT/100AF 2P
6. ELECTRICAL TRADE SIZE SHALL BE USED, A MINIMUM OF 15mmØ FOR METALLIC CONDUITS, 20mmØ FOR
8 SPARE 40AT/100AF 2P NON-METALLIC CONDUITS AND IN NO CASE SHALL BE THERE BE MORE THAT THE EQUIVALENT OF FOUR
TOTAL: 32277 140.33
QUARTER BENDS IN ANY ONE RUN.
7. CONDUITS SHALL BE PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. ALL ENDS OF CONDUITS
MAIN : 225 AMPS 2-POLE LUGS ONLY 2-125 mm² THHN Cu. WIRE IN 50mmØ CONDUIT SHALL BE PLUGGED TO PREVENT THE ENTRANCE OF WATER, MOISTURE AND FOREIGN MATTER AFTER
INSTALLATION.
8. SINGLE CONDUCTOR INSULATED THERMOPLASTIC, 600V WIRES SHALL BE USED IN CONDUIT, MINIMUM
SIZE OF WIRES SHALL BE 3.5mm² OR 2.0mmØ THW/TW FOR ALL LIGHTING AND POWER SYSTEM.
9. UPON COMPLETION OF ELECTRICAL CONSTRUCTION WORK, THE FOLLOWING TESTS SHALL BE
Ckt Size of PERFORMED BY THE CONTRACTOR INCLUSIVE OF THE INSTALLATION TO BE REPORTED IN DETAILS ON
Load Description WATTS AMPS Volts AT Size of Wire FORM APPROVED BY THE OWNER'S REPRESENTATIVE: A. INSULATION RESISTANCE TEST, 500VDC.
No. Conduits B. GROUND RESISTANCE TEST (5 OHMS)
1 AIR CONDITIONING OUTLET (3 4 HP) 1587 6.90 230 30AT/100AF 2P 2-5.5 mm² THHN Cu. WIRE 20mm Ø Conduit C. OPERATIONAL TEST
10. COLOR CODING OF WIRES SHALL BE AS FOLLOWS:
2 SPARE (1) 30AT/100AF 2P
LINE 1 - BLACK GROUND - GREEN
3 AIR CONDITIONING OUTLET ( 3
4 HP) 1587 6.90 230 30AT/100AF 2P 2-5.5 mm² THHN Cu. WIRE 20mm Ø Conduit LINE 2 - BLACK CONTROL 1 - WHITE
CONTROL 2 - BLUE
4 SPARE (1) 30AT/100AF 2P

5 CONVENIENCE OUTLET (15) 2700 11.74 230 20AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 20mm Ø Conduit

6 AIR CONDITIONING OUTLET (3 4 HP) 1587 6.90 230 30AT/100AF 2P 2-5.5 mm² THHN Cu. WIRE 20mm Ø Conduit

7 CONVENIENCE OUTLET (16) 2880 12.52 230 20AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 20mm Ø Conduit

8 AIR CONDITIONING OUTLET (12 HP) 1127 4.90 230 20AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 20mm Ø Conduit

9 LIGHTING OUTLET (10) 250 1.09 230 15AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 20mm Ø Conduit

10 LIGHTING OUTLET (12) 300 1.30 230 15AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 20mm Ø Conduit

TOTAL: 12018 52.25

LOAD COMPUTATION: ACU

TOTAL LOAD CURRENT = LINE CURRENT x 1.25 x D.F


TOTAL LOAD CURRENT = 52.25A x 1.25 x 0.90 = 58.78A
USE 60AT/100AF 2P 230V MAIN CB
USE 2-14mm² THHN CU. WIRE IN 20mmØ EMT CONDUIT MAIN FEEDER
>> TAP TO DISTRIBUTION PANEL DP AT GENSET ROOM
4
E1
SCHEDULE OF LOADS

5 SINGLE LINE DIAGRAM


E1 3
E1
VICINITY
SCALE
MAP
NTS

ARCHITECT - OF - RECORD PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

E2
DATE 01/23/2021
PROPOSED ADMIN BLDG FACILITY CAD BY GFMP
AR. JOHN LAWRENCE S. TING, UAP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9 266 Section 33 Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
DESIGNER NAME & SIGNATURE P.E.E. NAME & SIGNATURE
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
SEPTIC TANK

CB
DS

TO SEPTIC TANK

URINAL
LAV FD 3" Ø GRAY WATER PIPE 3" Ø GRAY WATER PIPE
WC

CO
CB CB
TO NEAREST SEWER
DS DS

PLAN
SECTION
TO NEAREST SEWER
3 CATCH BASIN DETAIL
P1 SCALE 1:30M

1 SANITARY LINE LAYOUT


P1 SCALE 1:100M
2000

1150 850

500 250 500 200

1500

1500
500
URINAL
LAV WC

PLAN
1" Ø P.E. PIPE CWL

300

300
1650

1650
SECTION
CV

M WM 4 SEPTIC TANK DETAIL


GV

FROM WATER LINE


2
P1
WATER
SCALE
LINE LAYOUT
1:100M
P1 SCALE 1:30M

ARCHITECT - OF - RECORD MASTER PLUMBER PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

PROPOSED ADMIN BLDG FACILITY


P1
DATE 01/23/2021
CAD BY GFMP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
AR. JOHN LAWRENCE S. TING, UAP
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 92 66 Section 33 NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
DESIGNER NAME & SIGNATURE
ADDRESS Calapan City APPROVED DATE 13/OCT/2021
CB
DS

IPE
R P
ATE
YW
RA
ØG
3" ER
EW
TS
ES
AR
NE
TO

CB

U00TM
DS

O
Y1 1
LA
:

NE
LI
E
PIP
TER
WA
TA
NK
ØG
RA
Y

Y
AR
IC 3"
PT
SE

TIC
TA
NK

NI T
SSACALE
WC
P
SE
TO AL
IN
UR
FD CO

CB UR
IN
AL
WC
1 P 1 L AV
EC
WL
PIP
.E.
ØP
DS LA
V 1"

O U100TM
AR
E ST
S EW
ER

LA Y1 :
TO
NE

E
LIN
TER
2
WCAALE
S
P1
E
IN
RL
CV M TE
W V WA
M OM
G FR

6
P1 SCALE
SANITARY LINE ISOMETRIC DIAGRAM
1:100M
5 WATER LINE ISOMETRIC DIAGRAM
P1 SCALE 1:100M

GENERAL NOTES

ARCHITECT - OF - RECORD MASTER PLUMBER PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
IMPORTANT:
PTR NO. 0569325
DRAFTED BY GFMP

PROPOSED ADMIN BLDG FACILITY


P2
DATE 01/23/2021
CAD BY GFMP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
AR. JOHN LAWRENCE S. TING, UAP
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 92 66 Section 33 NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
DESIGNER NAME & SIGNATURE
ADDRESS Calapan City APPROVED DATE 13/OCT/2021

You might also like