You are on page 1of 7

CPC Hardware Manual V1.

10

CPC
CAR OPERATING PANEL CONTROLLER BOARD

HARDWARE MANUAL
CPC Hardware Manual V1.10

Publisher ARKEL Elektrik Elektronik SAN. ve TİC. A.Ş.


Eyüp Sultan Mah. Şah Cihan Cad. No:69 Sancaktepe/Istanbul 34885 TURKIYE
TEL : +90(216) 540 67 24-25
Fax : +90(216) 540 67 26
E-mail: info@arkel.com.tr
www.arkel.com.tr
Date of issue 07.2020

Document version V1.10

This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all
of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the
right to make changes and improvements to any of the products described in this document without prior notice.

Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
CPC Hardware Manual V1.10

1. CPC Technical specifications


Environmental
Dimensions in mm
96 × 146 × 15
(W×L×D)
Weight
Working Temperature 0-60 ˚C
Electrical
Supply Voltage 24VDC(18-30VDC)
0.35W, Min. @24VDC supply*¹
Power Consumption
1.40W, Max.@24VDC supply *²
Button Inputs 0.12W,24VDC (for a single button)
0,48W, 24VDC (for a single button)
Button Outputs
16.8W, 24VDC (totally for 24 buttons)
Programmable Outputs (PT1) Open Collector (Max. 200mA)
Programmable Inputs (PI2,PI3,PI4) +24VDC Active High
Emergency Lighting Optional 12/24V Output(Max. 200mA)
Gong Voice Output 0,5W(?R) Speaker
External Supply (BAT-1000) 12V(Max. 200mA)
Notes:
1. No recorded call, all Leds are passive, display is inactive
2. Recorded active calls, Leds are lighting.

2. Functional specifications
• 24 Button support with lighting
• Handle entire car functionality
• Can bus socket for the cabinet display
• Socket for IBC connection
• Cascaded connection up to 73 button with A and B side doors
• 3 programmable inputs and output
• Gong sound output and volume control
• 5 spare connections.
• 12V Output
• Programmable transistor output.
CPC Hardware Manual V1.10

3. CPC Board Overview

14
8
1
4
11
13

2
12

4
10

1. Programmable button input. (through Arcode and Arem devices)


2. Door open, door close and air ventilation button sockets.
3. CPC configuration settings (0-23,24-47,48-64 floors and Door A or Door B)
4. CPU indicator led
5. Call button and button lighting (for 24 buttons)
6. Speaker connection
7. Spare connections (for intercom etc.), 12V supply output
8. 5V Supply indicator
9. Speaker volume adjustment trimpot
10. IBC connection port
11. Programmable transistors, emergency lighting, emergency button, 100-1000 terminals
12. 24V Supply indicator
13. emergency lighting, emergency button terminals
14. CANBus connectors (2 big size, 1 small size)
CPC Hardware Manual V1.10

4. Dimensions
The dimensions of CPC board are shown below:
CPC Hardware Manual V1.10

5. CPC Common Connections Diagram

6. CPC Board Indicators and meanings


LED Color Cadence Reason
CPU Green Normal blink Micro controller runs in normal mode.
Fast blink Micro controller runs in boat loader mode.
Off Problem with the micro controller
5V Green On Power good
Off Power off
If 100 Led is On then a problem with internal power supply.
100 Green On 24V Supply is good
Off No 24V supply
CPC Hardware Manual V1.10

7. CPC Adjustments
7.1. Volume Adjustment
It is possible to adjust gong sound volume with trimpot on the CPC board. To increase volume trimpot is rotated in
counterclockwise. To decrease sound volume clockwise rotation is required.
7.2. CPC Configuration Settings
CPC boards are configured via 4 independent dip switches those functions are listed in following table.

S1 S2 Configuration S3 S4 Configuration
0 0 CPC1, 0-23 Floors 0 0 Undefined
0 1 CPC2, 24-47 Floors 0 1 B Side door call buttons
1 0 CPC3, 48-72 Floors 1 0 A Side door call buttons
1 1 Undefined. 1 1 A and B side door call buttons