You are on page 1of 115

Page 1 of 37

FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

CE
EMC DIRECTIVE (2014/30/EU)
TEST REPORT

FCC Part 15, ICES-003, VCCI, CNS13438,


AS/NZS CISPR 32, EN 55032,
and EN55024
TEST REPORT
for

INTERNAL HARD DISK DRIVE


R/N: 800055

Prepared for

WESTERN DIGITAL CORP.


3355 MICHELSON DRIVE, C218-A
IRVINE, CA 92612-0684

Prepared by: _____________________

EUGENE ADAMS

Approved by: ____________________

MATT HARRISON

COMPATIBLE ELECTRONICS INC.


20621 PASCAL WAY
LAKE FOREST, CALIFORNIA 92630
(949) 587-0400

DATE: February 1, 2016

REPORT APPENDICES TOTAL


BODY A B C D E
PAGES 37 2 2 2 38 34 115
This report shall not be reproduced, except in full, without the written approval of Compatible Electronics.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 2 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

TABLE OF CONTENTS
Section / Title PAGE
GENERAL REPORT SUMMARY 5
SUMMARY OF TEST RESULTS 6
SUMMARY OF TEST RESULTS continued 7
1. PURPOSE 8
2. ADMINISTRATIVE DATA 9
2.1 Location of Testing 9
2.2 Traceability Statement 9
2.3 Cognizant Personnel 9
2.4 Date Test Sample was received 9
2.5 Disposition of the Test Sample 9
2.6 Abbreviations and Acronyms 9
3. APPLICABLE DOCUMENTS 10
4. DESCRIPTION OF TEST CONFIGURATION 12
4.1 Description of Test Configuration – (Emissions) 12
4.2 Description of the Test Configuration – (Immunity) 14
5. LISTS OF EUT, ACCESSORIES AND TEST EQUIPMENT 16
5.1 EUT and Accessory List 16
5.2 Emissions Test Equipment 17
5.3 Immunity Test Equipment 18
5.4 Test Software 20
6. TEST SITE DESCRIPTION 21
6.1 Test Facility Description 21
6.2 EUT Mounting, Bonding and Grounding 21
6.3 Facility Environmental Characteristics 21
6.4 Measurement Uncertainty 21
7. TEST PROCEDURES 22
7.1 RF Emissions 22
7.2 Electrostatic Discharge Tests 27
7.3 Radio-Frequency Electromagnetic Field 30
7.4 Fast Transient Common Mode Tests 31
7.5 Surge Immunity Test 32
7.6 Conducted disturbances induced by RF Electromagnetic Field Test 33
7.7 Power Frequency Magnetic Field Test 34
7.8 Voltage Dips, Short Interruptions, and Voltage Variations 35
7.9 Quasi-Stationary Harmonics and Flicker Test 36
8. TEST PROCEDURE DEVIATIONS 37
9. CONCLUSIONS 37

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 3 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

LIST OF APPENDICES

APPENDIX TITLE

A Laboratory Accreditations
B Modifications to the EUT
C Additional Models Covered Under This Report
D Diagrams, Charts and Photos
 Test Setup Diagrams
 Antenna and Amplifier Gain Factors
 Radiated and Conducted Emissions Photos
 Immunity Photos
E Data Sheets

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 4 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

LIST OF FIGURES

FIGURE TITLE

1 Conducted Emissions Test Setup


2 Plot Map And Layout of Test Site
3 High Frequency Test Volume
4 Electrostatic Discharge Test Setup
5 Radio-Frequency Electromagnetic Field Test Setup
6 Fast Transients Common Mode Test Setup
7 Surge Immunity Test Setup
8 Conducted Disturbances Induced by RF Fields
9 Power Frequency Magnetic Field Test Setup
10 Voltage Dips, Voltage Variations, and Short interruptions

LIST OF TABLES

TABLE TITLE

1 Conducted Emissions Results 100V


2 Conducted Emissions Results 110V
3 Conducted Emissions Results 220V
4 Conducted Emissions Results 230V
5 Radiated Emissions Results 100V
6 Radiated Emissions Results 110V
7 Radiated Emissions Results 220V
8 Radiated Emissions Results 230V

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 5 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

GENERAL REPORT SUMMARY


This electromagnetic emission and immunity test report is generated by Compatible Electronics Inc., which is an
independent testing and consulting firm. The test report is based on testing performed by Compatible Electronics
personnel according to the measurement procedures described in the test specifications given below and in the "Test
Procedures" section of this report.

The measurement data and conclusions appearing herein relate only to the sample tested and this report may not be
reproduced in any form except in full, without the written permission of Compatible Electronics.

This report must not be used to claim product certification, approval or endorsement by NVLAP, NIST, or any agency
of the federal government.

Device Tested: HARD DISK DRIVE


R/N: 800055
S/N: NONE

Product Description: This is a Digital Storage Hard Disk Drive.

Modifications: The EUT was not modified during the testing.

Manufacturer: Western Digital Corp.


3355 Michelson Drive, C218-A
Irvine, CA 92612-0684

Test Dates: April18-22, 2016

Test Specifications: Emissions and Immunity requirements


CFR Title 47, Part 15, Subpart B; ICES-003, VCCI, CNS13438, AS/NZS CISPR 32
European Standards CISPR 22, EN55032 and EN55024.

The specification EN55024 is a product family EMC standard which references the following
specifications:

EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 6 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

SUMMARY OF TEST RESULTS

TEST DESCRIPTION RESULTS


1 Conducted RF Emissions, 150 kHz – 30 MHz. Complies with the Class B limits of FCC, ICES-003, VCCI,
CNS13438, AS/NZS CISPR 32, and EN550324
See section 6.4 for Measurement Uncertainty

2 Conducted RF Emissions – Telecom Lines The EUT has no telecom lines; therefore this test was not performed.
150 kHz – 30 MHz.
3 Radiated RF Emissions, 30 MHz – 30000 MHz. Complies with the Class B limits of FCC, ICES-003, VCCI,
CNS13438, AS/NZS CISPR 32, and EN550324
See section 6.4 for Measurement Uncertainty

4 Direct ESD, Air Discharge, Complies with the relevant requirements of EN55024. The unit
2 kV, 4 kV, 8 kV, 12kV, and 15kV operates within the specifications. *See XX below for uncertainty
(insulated surfaces). notes.
5 Complies with the relevant requirements of EN55024. The unit
Direct ESD, Contact Discharge,
operates within the specifications. *See XX below for uncertainty
2 kV, 4 kV, and 8kV (conductive surfaces).
notes.
6 Indirect ESD, Complies with the relevant requirements of EN55024. The unit
2 kV, 4 kV, and 8kV (HCP & VCP). operates within the specifications. *See XX below for uncertainty
notes.
7 Complies with the requirements of EN55024. The unit operates within
Radio-Frequency Electromagnetic Field,
its specifications. *See XX below for uncertainty notes. Variations of
80 MHz to 2000 MHz, 10 V/m with an
measured field strength due to reflections from the EUT are not
amplitude modulated 1 kHz sine wave at 80%.
included in the uncertainty calculations.
8 Fast Transients Common Mode, 0.5 kV & 1.0 Complies with the requirements of EN55024. The unit operates within
kV on AC Power lines and 0.5 kV on data its specifications. *See XX below for uncertainty notes.
lines.
9 Surge Immunity Test Differential Mode, 0.5 Complies with the requirements of EN55024. The unit operates within
kV and 1.0 kV and common mode 2.0 kV on its specifications. *See XX below for uncertainty notes.
power lines.
10 Surge Immunity Test Telecommunication Lines The EUT has no telecommunication cables that connect directly to
0.5 kV and  1.0 kV outdoor cables; therefore this test was deemed unnecessary. *See XX
below for uncertainty notes.
11 Radio-Frequency Electromagnetic Conducted Complies with the requirements of EN55024. The unit operates within
Field, .150 MHz to 80 MHz, 3Vrms with an its specifications. *See XX below for uncertainty notes.
amplitude modulated 1 kHz sine wave at 80%.
12 Power Frequency Magnetic Field Susceptibility, Complies with the requirements of EN55024. The unit operates within
3 A/m @ 50Hz and 60Hz, X, Y, & Z-axis. its specifications. *See XX below for uncertainty notes.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 7 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

SUMMARY OF TEST RESULTS continued

TEST DESCRIPTION RESULTS


13 Voltage Dips and Voltage Variations, Short Complies with the requirements of EN55024. The unit operates within
Interrupts, >95%@10ms, 30%@500ms, and its specifications. *See XX below for uncertainty notes.
>95%@5sec reduction of rated voltage.
14 Quasi-Stationary Current Harmonics Test The EUT test results came in below 75W therefore this test was
230V@50Hz, 39th Odd Harmonics and 40th deemed non applicable.
Even harmonics.
15 Voltage Fluctuation and Flicker Test The EUT is not likely to cause voltage fluctuations or flicker; therefore
230V@50Hz. this test was not performed.
XX Note that for all immunity tests above, It has been demonstrated that the generator and or the test configuration meets the
specified requirements in the relevant technical standard. Calibration data is on file at the lab.
reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 8 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

1. PURPOSE

This document is a Qualification test report based on the Emissions and Immunity tests performed on
the INTERNAL HARD DISK DRIVE, R/N: 800055. The emissions measurements were performed
according to the measurement procedure described in AS/NZS CISPR 32, ICES -003, VCCI,
CNS13438, and EN55032. The tests were performed in order to determine whether the
electromagnetic emissions from the equipment under test, referred to as EUT hereafter, are within the
Class B specification limits defined in CISPR 22 (EN55022) and EN55032 (Electromagnetic
compatibility of multimedia equipment – Emissions requirements).. Under paragraph G of section
15.109 of the Code of Federal Regulations Title 47, Part 15 of the FCC rules, FCC accepts the
international standards set forth in CISPR 22.

The immunity tests were performed according to the measurement procedure described in EN55024 -
(Information Technology Equipment – Immunity Characteristics – Limits and Methods of
Measurement). These tests were performed in order to determine whether the EUT would accept any
interference and still perform within the performance criteria described in section 4.2.1 of this report.
The tests were performed by Compatible Electronics personnel; also the unit was operated and
monitored for susceptibility by Compatible Electronics personnel.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 9 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

2. ADMINISTRATIVE DATA
2.1 Location of Testing

The emissions and immunity tests described herein were performed at the test facility of Compatible
Electronics, 20621 Pascal Way, Lake Forest, California 92630.
2.2 Traceability Statement

The calibration certificates of all test equipment used during the test are on file at the location of the
test. The calibration is traceable to the National Institute of Standards and Technology (NIST).
For equipment used for immunity testing, refer to the applicable calibration certificates for tolerance
and uncertainty information, which is on file at the location of the test.
2.3 Cognizant Personnel

Western Digital Corp.

Troy Gomez Senior Staff Engineer, Regulatory Compliance

Compatible Electronics, Inc.

Eugene Adams Test Engineer


Matt Harrison Lab Manager
Jeff Klinger Director of EMC Engineering
2.4 Date Test Sample was received

The test sample was received on January 26, 2016.


2.5 Disposition of the Test Sample

The test sample was returned to Western Digital Corp.


2.6 Abbreviations and Acronyms

The following abbreviations and acronyms may be used in this document.

EFT Electrical Fast Transients


RF Radio Frequency
ESD Electrostatic Discharge
EMI Electromagnetic Interference
EMC Electromagnetic Compatibility
VCP Vertical Coupling Plane
HCP Horizontal Coupling Plane
EUT Equipment Under Test
R/N Regulatory Number
P/N Part Number
S/N Serial Number
HP Hewlett Packard
ITE Information Technology Equipment
CML Corrected Meter Limit
LISN Line Impedance Stabilization Network

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 10 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

3. APPLICABLE DOCUMENTS

The following documents are referenced or used in the preparation of this test report.

SPEC TITLE

EN55022:2010/ Limits and methods of measurements of radio disturbance characteristics of


CISPR 22: 2008 information technology equipment

EN 55032: Electromagnetic compatibility of multimedia equipment – Emission requirements


2012

EN 55024: Information Technology Equipment Immunity – Characteristics – Limits and


2010 Methods of Measurement

AS/NZS CISPR 32: Electromagnetic compatibility of multimedia equipment – Emission requirements


2015

ICES 003: Issue 5 Spectrum Management and Telecommunications Policy Interference-Causing


Equipment Standard – Digital Apparatus
CNS13438: 2006
(per Oct. 1, 2010 Limits and methods of measurement of radio interference characteristics of
update)
information technology equipment (ITE)

ANSI C63.4: 2009 Methods of measurement of radio-noise emissions from low voltage electrical and
electronic equipment in the range of 9 kHz to 40GHz

V-3/(2015.04) VCCI Technical Requirements.

CISPR 16-1-4 Specification for radio disturbance and immunity measuring apparatus and methods.
2010 Part 1-4 radio disturbance and immunity measuring apparatus – Ancillary Equipment
– Radiated Disturbances

EN 61000-4-2 Electromagnetic compatibility – Part 4: Testing and measurement techniques –


2009 Section 2: Electrostatic discharge immunity test

EN 61000-4-3 Electromagnetic compatibility – Part 4: Testing and measurement techniques –


2006 Section 3: Radiated, radio-frequency electromagnetic field test

EN 61000-4-4 Electromagnetic compatibility – Part 4: Testing and measurement techniques –


2004 Section 4: Electrical fast transient/burst immunity test

EN 61000-4-5 Electromagnetic compatibility – Part 4: Testing and measurement techniques –


2006 Section 5: Surge immunity test

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 11 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

SPEC TITLE

EN 61000-4-6 Electromagnetic compatibility – Part 4: Testing and measurement techniques –


2009 Section 6: Immunity to conducted disturbances, Induced by radio-frequency fields

EN 61000-4-8 Electromagnetic compatibility – Part 4: Testing and measurement techniques –


2010 Section 8: Power frequency magnetic field immunity test

EN 61000-4-11 Electromagnetic Compatibility. Part 4: Testing and measurement techniques.


2004 Section 11: Voltage dips, short interruptions and voltage variations immunity tests

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 12 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

4. DESCRIPTION OF TEST CONFIGURATION


4.1 Description of Test Configuration – (Emissions)

The EUT is setup in a tabletop configuration. The EUT is connected to the host desktop computer via
power and SATA III internally. The host desktop computer is connected to the monitor, switch,
keyboard, mouse, and microphone/headphone ports via video, Ethernet, PS/2, USB, and microphone
and headphone ports respectively. The EUT is being exercised by running an automated program that
writes data to the disk and reads the data and scans for errors. The automated program is set to loop
upon completion of the test.

The cables were moved to maximize the emissions. The final conducted and radiated data was taken
in the continuously exercising mode of operation. All initial investigations were performed with the
EMI Receiver in manual mode scanning the frequency range continuously. The cables were bundled
and routed as shown in the photographs in Appendix D.
4.1.1 Photograph of Test Configuration

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 13 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

4.1.2 Cable Construction and Termination

Cable 1
This is a 1.5 meter, braid shielded, video cable that connects the desktop computer to the monitor.
The cable has DVI connectors at each end. The cable is bundled to a length of 1 meter. The cable
has a molded ferrite on both the desktop computer end and the monitor end.

Cable 2
This is a 2 meter, unshielded, Ethernet cable that connects the desktop computer to the switch. The
cable has RJ-45 connectors at each end. The cable is bundled to a length of 1 meter.

Cable 3
This is a 1 meter, foil shielded, cable that connects the desktop computer to the keyboard. The cable
has PS/2 connector at the desktop computer end and is hardwired into the keyboard.

Cable 4
This is a 1 meter, foil shielded, cable that connects the desktop computer to the mouse. The cable has
USB connector at the desktop computer end and is hardwired into the mouse.

Cable 5
This is a 1 meter, unshielded, cable that connects the desktop computer to the microphone/headphone.
The cable has a 3.5mm phone jack connector at the desktop computer end and is hardwired into the
microphone/headphone.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 14 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

4.2 Description of the Test Configuration – (Immunity)

The EUT was operating as described in section 4.1 of this report. The EUT was observed for
susceptibility by monitoring the status of the read/write program.
4.2.1 Susceptibility Criteria

TEST PERFORMANCE CRITERIA

Electrostatic Discharge B

Radio-Frequency A
Electromagnetic Field

Fast Transients B
Common Mode

Surge Immunity Test B

Conducted Disturbances A
Induced by RF Fields

Power Frequency A
Magnetic Field
Susceptibility

Voltage Dips and Voltage B&C


Interruptions and Short
Interruptions

Performance criteria A: The apparatus shall continue to operate as intended. No degradation of


performance or loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance. If the minimum performance level or the permissible performance
loss is not specified by the manufacturer then either of these may be derived from the product
description and documentation and what the user may reasonably expect from the apparatus if used as
intended.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 15 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

4.2.2 Susceptibility Criteria (Continued)

Performance criteria B: The apparatus shall continue to operate as intended after the test. No
degradation of performance or loss of function is allowed below a performance level specified by the
manufacturer, when the apparatus is used as intended. In some cases the performance level may be
replaced by a permissible loss of performance. During the test, degradation of performance is
however allowed. No change of actual operating state or stored data is allowed. If the minimum
performance level or the permissible performance loss is not specified by the manufacturer then either
of these may be derived from the product description and documentation and what the user may
reasonably expect from the apparatus if used as intended.

Performance criteria C: Temporary loss of function is allowed, provided the loss of function is self-
recoverable or can be restored by the operation of the controls.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 16 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

5. LISTS OF EUT, ACCESSORIES AND TEST EQUIPMENT


5.1 EUT and Accessory List

# EQUIPMENT TYPE MANUFACTURER R/N SERIAL NUMBER


1 INTERNAL HARD DISK WESTERN DIGITAL 800055 S/N: NONE
DRIVE (EUT) CORP.

# ACCESSORY TYPE MANUFACTURER MODEL SERIAL NUMBER


2 DESKTOP COMPUTER DELL T3610 DXF2F21
3 MONITOR GATEWAY 900W MLR74 50H 10103
4 KEYBOARD DELL SK-8100 CN-09C487-38844-17K-8797
5 MOUSE DELL MS111-L CN-09RRC7-48723-11T-07XT
6 SWITCH LINKSYS EZXS55W R9103047053938
7 MICROPHONE/HEADPH PLANTRONICS NONE NONE
ONE

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 17 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

5.2 Emissions Test Equipment

EQUIPMENT MANUFACTURER MODEL SERIAL CAL. CAL. DUE


TYPE NUMBER NUMBER DATE DATE
Computer Compatible Electronics NONE NONE N/A N/A
EMI Receiver Rohde & Schwarz ESIB40 100219 9/22/2015 9/22/2016
Antenna, CombiLog Com Power AC-220 25857 5/21/2015 5/21/2016
Antenna, Horn Com Power AH-118 071250 7/1/2014 7/1/2016
Preamplifier Com Power PAM-118A 551033 8/25/2015 8/25/2016
LISN (EUT) Com Power LI-215 191935 4/4/2016 4/4/2017
LISN (ACC) Com Power LI-215 191937 4/4/2016 4/4/2017

Mast, Antenna
Positioner Sunol Science Corporation SC104V 081309-1 N/A N/A
Antenna Mast Sunol Science Corporation TWR 95-4 081309-3 N/A N/A
Turntable Sunol Science Corporation FM2011VS NONE N/A N/A

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 18 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

5.3 Immunity Test Equipment

EQUIPMENT MANUFACTURER MODEL SERIAL CAL. DATE CAL. DUE


TYPE NUMBER NUMBER DATE
GENERAL TEST EQUIPMENT USED FOR ALL TESTS
Barometer Abbeon BAR 130 B #2503 7/22/2015 7/22/2016
Hygrometer Abbeon HTAB169B #2499 7/25/2015 7/25/2016
Computer Test Hewlet Packard Pavilion 4530 US92010480 NCR NCR
Station
TEST EQUIPMENT USED FOR ELECTROSTATIC DISCHARGE TESTS
Simulator ESD Thermo Keytek MINIZap 702261 6/24/2015 6/24/2016
TEST EQUIPMENT USED FOR RF RADIATED ELECTROMAGNETIC IMMUNITY TESTS
Amplifier, RF Power OPHIR XRF761 1002 NCR NCR
Antenna, Hybrid Log TDK HLP-2603 130534 NCR NCR
Periodic
Field Probe, Monitor Amplifier Research FM2000 #3150 NCR NCR
Field Probe, Isotropic Amplifier Research FP2080 24790 1/8/2016 1/8/2017
Generator, RF Signal Com Power SIG-200 2173 1/5/2016 1/5/2017
TEST EQUIPMENT USED FOR ELECTRICAL FAST TRANSIENTS AND SURGE TESTS
Immunity Test Keytek EMCproPLUS 0708238 9/28/2015 9/28/2016
System
Clamp, Capacitive Keytek CCL-4/S 9301370 9/28/2015 9/28/2016
Coupling
TEST EQUIPMENT USED FOR RF CONDUCTED ELECTROMAGNETIC IMMUNITY TESTS
Amplifier RF Power Amplifier Research 100A250 24698 NCR NCR
CDN M3 (EUT) Com Power CDN M3-25 521011 3/14/2015 3/14/2016
CDN M3 (ACC) Com Power CDN M3-25 521012 NCR NCR
Probe, Bulk Currrent TEGAM 95236-1 10669 NCR NCR
Injection
Coupler Directional Werlatone C6021 8915 NCR NCR
Generator RF Signal Com Power SIG-200 2173 1/5/2016 1/5/2017

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 19 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

5.3.1 Immunity Test Equipment (Continued)

EQUIPMENT MANUFACTURER MODEL SERIAL CAL. DATE CAL. DUE


TYPE NUMBER NUMBER DATE
TEST EQUIPMENT USED FOR POWER FREQUENCY MAGNETIC FIELD IMMUNITY TESTS
Antenna H-Field Compatible Electronics NONE NONE NCR NCR
Multimeter Fluke 77 77650234 4/20/2015 4/20/2016
Power Source – Agilent Technologies 6813B US38390530 NCR NCR
Analyzer AC
Transformer, Compatible Electronics CE-H101 003 NCR NCR
Step-down

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 20 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

5.4 Test Software

LAB(S) SOFTWARE TITLE MANUFACTURER VERSION


E-Field Software Program (Field
Q Uniformity) Compatible Electronics 1.0, FUTA100
Q AutoSigGen Compatible Electronics SEGI
S,Q CEWare Keytek 4.00.950
Measurement and Automation
Q Software National Instruments 1.0.1 Build 29
Measurement and Automation
P, R Software TDK TestLab 5.53

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 21 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

6. TEST SITE DESCRIPTION


6.1 Test Facility Description

The radiated emissions measurements were performed on a 10 meter Open Area Test Site. The
conducted emissions measurements were performed in a semi-anechoic chamber. All RF immunity
tests were performed in a shielded enclosure 23 feet wide, 23 feet long and 12 feet high. Please refer
to section 2.1 and 7.1.3 of this report for EMI test location.

6.2 EUT Mounting, Bonding and Grounding

For all tests except for ESD, EFT and the Conducted Immunity tests, the EUT was set up on a 1.0 by
1.5 by 0.8 meter high non-conductive table, which was placed on the ground plane. For ESD testing,
the unit was mounted 0.5 millimeters above the 0.8 meter by 1.6 meter horizontal coupling plane. For
the Conducted Immunity and EFT tests, the EUT was mounted 10cm above the GRP.

The EUT was grounded through the AC power cord.

6.3 Facility Environmental Characteristics

When applicable refer to the data sheets in Appendix E for the relative humidity, air temperature and
barometric pressure.

6.4 Measurement Uncertainty


“Compatible Electronics’ Ulab value is less than Ucispr, thus based on this − compliance is deemed to occur if
no measured disturbance exceeds the disturbance limit

Measurement Ucispr Ulab = 2 uc (y)


Conducted disturbance (mains port) (150 kHz – 30 MHz) 3,6 dB 2.88 dB
Radiated disturbance (electric field (30 MHz – 1 000 MHz) 5,2 dB 3.53 dB
strength on an open area test site or
alternative test site)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 22 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7. TEST PROCEDURES

The following sections describe the test methods and the specifications for the tests. Test results are
also included in this section.
7.1 RF Emissions
7.1.1 Conducted Emissions Test

The EMI Receiver was used as a measuring meter. A 10 dB attenuation pad was used for the
protection of the EMI Receiver input stage. All factors associated with attenuator and cables were
recorded into the EMI Software Program accordingly to display the actual corrected measured level.
The LISN output was connected to the input of the EMI Receiver. The output of the second LISN
was terminated with 50-ohm termination. The effective measurement bandwidth used for the
conducted emissions test was 9 kHz.

Please see section 6.2 of this report for mounting, bonding and grounding of the EUT. The EUT was
powered through the LISN, which was bonded to the ground plane. The LISN power was filtered and
the filter was bonded to the ground plane. The EUT was set up with the minimum distances from any
conductive surfaces as specified in EN55032 and CISPR 22. The excess power cord was wrapped in
a figure eight pattern to form a bundle not exceeding 0.4 meters in length.

The initial test data was taken in manual mode while scanning the frequency ranges of 0.15 MHz to
30 MHz. The conducted emissions from the EUT were maximized for operating mode as well as
cable placement. Once a predominant frequency (within 12 dB of the limit) was found, it was more
closely examined with the spectrum analyzer span adjusted to 1 MHz.

The final data was collected under program control by the computer in several overlapping sweeps by
running the EMI Receiver at a minimum scan rate of 10 seconds per octave. The six highest
emissions are listed in Table 1 – Table 4.

7.1.2 Conducted Emissions Test on Telecommunication Lines

Test Results:

The EUT had no telecommunication ports; therefore this test was deemed unnecessary and thus was
not performed beyond an exploratory test. Had this test been applicable it would have been
performed as described below.

The EMI Receiver was used as a measuring meter. All factors associated with attenuator and cables
were recorded into the EMI Software Program accordingly to display the actual corrected measured
level. The current probe output was read by the EMI Receiver. The effective measurement
bandwidth used for the conducted emissions test was 9 kHz. The initial test data was taken while
scanning the frequency ranges of 0.15 MHz to 30 MHz. The conducted emissions from the EUT
were maximized for operating mode as well as cable placement.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 23 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.1.3 Radiated Emissions Test

The EMI Receiver was used as the measuring meter. A preamplifier was used to increase the
sensitivity of the instrument. The EMI Receiver was used in the Analyzer mode feature activated. In
this mode, the EMI receiver can then record the actual frequency to be measured. This final reading
is then taken accurately in the EMI Receiver mode, which takes into account the cable loss, amplifier
gain and antenna factors, so that a true reading is compared to the true limit. A quasi-peak reading
was taken only for those readings, which are marked accordingly on the data sheets. The effective
measurement bandwidth used for the radiated emissions test was according to the frequency measured
(120 kHz for 30 MHz to 1 GHz and 1 MHz for 1 GHz and above).

Broadband Combilog Antenna and horn antennas were used as transducers during the measurement.
The Combilog Antenna was used from 30 MHz to 1000 MHz and the horn was used above 1 GHz.
Furthermore, the frequency span was reduced during the preliminary investigations as deemed
necessary.

The open field test site of Compatible Electronics, Inc. was used for radiated emission testing from
30MHz to 1000MHz. The TDK FAC-3 shielded test chamber of Compatible Electronics, Inc. was
used for radiated emissions testing from 1GHz to 30GHz. This test site is set up according to CISPR
16. Please see section 6.2 of this report for mounting, bonding and grounding of the EUT. The
turntable supporting the EUT is remote controlled using a motor. The turntable permits EUT rotation
of 360 degrees in order to maximize emissions. Also, the antenna mast allows height variation of the
antenna from 1 meter to 4 meters. Data was collected in the worst case (highest emission)
configuration of the EUT. At each reading, the EUT was rotated 360 degrees and the antenna height
was varied from 1 to 4 meters (for E field radiated field strength).

The presence of ambient signals was verified by turning the EUT off. In case an ambient signal was
detected, the measurement bandwidth was reduced temporarily and verification was made that an
additional adjacent peak did not exist. This ensures that the ambient signal does not hide any
emissions from the EUT.

The EUT was tested at a 10 meter test distance from 30 MHz to 1 GHz, and at a 3 meter test distance
above 1 GHz to obtain final test data. The six highest emissions are listed in Table 5 - Table 8.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 24 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.1.4 RF Emissions Test Results


Table 1.0 CONDUCTED EMISSION RESULTS 100V
INTERNAL HARD DISK DRIVE, R/N: 800055

Frequency Emission Level* Specification Limit Delta


dBuV (Spec limit-Emission)
MHz dBuV dB

0.49 N 45.55 # 56.10 -10.55

0.49 N 45.66 # 56.24 -10.58

1.21 N 44.75 # 56.00 -11.25

1.23 N 44.75 # 56.00 -11.25

1.74 N 44.65 # 56.00 -11.35

1.23 N 44.62 # 56.00 -11.38


Table 2.0 CONDUCTED EMISSION RESULTS 110V
INTERNAL HARD DISK DRIVE, R/N: 800055

Frequency Corrected Reading* Specification Limit Delta


dBuV (Cor. Reading – Spec.
MHz dBuV Limit)
dB

1.17 N 47.12 # 56.00 -8.88

0.52 L 44.23 # 56.00 -11.77

0.52 N 44.17 # 56.00 -11.83

0.53 L 42.86 # 56.00 -13.14

1.16 N 42.18 # 56.00 -13.82

0.51 L 42.13 # 56.00 -13.87

Notes:
* The complete emissions data is given in Appendix E of this report.

** The factors for the antenna and preamplifier gain are attached in Appendix D of this report.

# Quasi-Peak Reading

A Average Reading

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 25 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Table 3.0 CONDUCTED EMISSION RESULTS 220V


INTERNAL HARD DISK DRIVE, R/N: 800055

Frequency Emission Level* Specification Limit Delta


dBuV (Spec limit-Emission)
MHz dBuV dB

0.57 L 51.40 # 56.00 -4.60

0.57 N 51.17 # 56.00 -4.83

0.57 N 50.76 # 56.00 -5.24

0.56 L 50.29 # 56.00 -5.71

0.55 L 50.21 # 56.00 -5.79

0.55 N 49.92 # 56.00 -6.08


Table 4.0 CONDUCTED EMISSION RESULTS 230V
INTERNAL HARD DISK DRIVE, R/N: 800055

Frequency Corrected Reading* Specification Limit Delta


dBuV (Cor. Reading – Spec.
MHz dBuV Limit)
dB

0.62 L 52.49 # 56.00 -3.51

0.62 N 52.38 # 56.00 -3.62

0.61 L 51.58 # 56.00 -4.42

0.61 N 51.38 # 56.00 -4.62

0.56 L 50.12 # 56.00 -5.88

0.57 L 50.10 # 56.00 -5.90

Notes:
* The complete emissions data is given in Appendix E of this report.

** The factors for the antenna and preamplifier gain are attached in Appendix D of this report.

# Quasi-Peak Reading

A Average Reading

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 26 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Table 5.0 RADIATED EMISSION RESULTS


INTERNAL HARD DISK DRIVE, R/N: 800055

Frequency Corrected Reading* Specification Limit Delta


dBuV (Cor. Reading – Spec.
MHz dBuV Limit)
dB

1323.00 H 46.71 A 50.00 -3.29

48.20 V 34.87 # 40.45 -5.58

84.30 V 34.61 # 40.45 -5.84

96.30 H 34.22 # 40.45 -6.23

2490.00 H 42.02 A 50.00 -7.98

30.70 V 32.30 # 40.45 -8.15

Notes:
* The complete emissions data is given in Appendix E of this report.

** The factors for the antenna and preamplifier gain are attached in Appendix D of this report.

# Quasi-Peak Reading

A Average Reading

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 27 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.2 Electrostatic Discharge Tests

An ESD Generator was used for this test. The characteristics consist of an energy storage capacitor:
150pF; discharge resistance: 330 Ohms; charging resistor: 100 Megaohms; tolerance of voltage
indication: +5%; polarity of output voltage: positive and negative. The waveshape conforms to EN
61000-4-2.
7.2.1 Direct ESD - Air Discharge

In the Air ESD test, the EUT was exposed to a direct air discharge at all user accessible surfaces. The
ESD arc was drawn directly to any insulated or conductive point on the EUT. The test simulated a
situation in which any person or object carrying an electrostatic charge discharges it to any point on
the equipment. The ground strap of the ESD generator was connected to the earth ground (shield
room ground reference plane) and was a minimum of 0.2 m away from the EUT.

Please see section 6.2 of this report for mounting, bonding and grounding of the EUT. The EUT was
operated and configured as described in section 4.2 of this report. The EUT was set up as shown in
Appendix D of this report. Photographs of the test equipment, and EUT setup during the test are in
Appendix D. The data sheets are in Appendix E.

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. The test point
locations were selected based on an exploratory test of inducing 20 discharges per second onto all
surfaces of the unit. The test point locations selected for the final test are listed in the data sheets
attached in Appendix E.

The test voltages were increased from 2.0 kV to 15.0 kV, in order to eliminate errors related to the
"window" effect associated with ESD testing. Also, testing in increments helps determine the voltage
threshold without severely damaging the unit. The final test was performed with 10 single shot
discharges on each selected point in each polarity. The rounded discharge probe was used for the test.
After completion of the test, a functional test was performed on the EUT to ensure proper operation.

Test Results:

The EUT complies with the relevant requirements of EN55024. The unit operates within the
specifications for air discharge at 2.0 kV, 4.0 kV, 6.0 kV, 8.0 kV, 12kV, and 15kV (insulated
surfaces).

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 28 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.2.2 Direct ESD - Contact Discharge

In the contact ESD test, the EUT was exposed to a direct contact discharge at all conductive user
accessible surfaces. The ESD arc was drawn directly to any conductive point on the equipment under
test. The test provides a repeatable method to determine immunity of the EUT to electrostatic
discharges. The ground strap of the ESD generator was connected to the earth ground (shield room
ground reference plane) and was a minimum of 0.2 m away from the EUT.

Please see section 6.2 of this report for mounting, bonding and grounding of the EUT. The EUT was
operated and configured as described in section 4.2 of this report. The EUT was set up as shown in
Appendix D of this report. Photographs of the test equipment and EUT setup during the test are in
Appendix D. The data sheets are in Appendix E.

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. The test point
locations were selected based on the exploratory test of inducing 20 discharges per second onto all
surfaces of the unit. The test point locations selected for the final test are listed in the data sheets
attached in Appendix E.

The test voltages were 2.0 kV, 4.0 kV, and 8kV in order to eliminate errors related to the
"window" effect associated with ESD testing. Also, testing in increments helps determine the
threshold without severely damaging the unit. The final test was performed with single shot
discharges on all the selected points.

The pointed discharge probe was touching the conductive surface of the unit before initiating the
discharge. For painted surfaces, the sharp tip of the probe was used to penetrate the paint before
providing discharge to the EUT. At least 25 discharges (in both polarities) were applied at each test
point. After completion of the test, a functional test was performed on the EUT to ensure proper
operation.

Test Results:

The EUT complies with the relevant requirements of EN55024 as per the requirements described in
EN61000-4-2. The unit operates within the specifications for contact discharge at 2.0 kV 4.0 kV,
and 8kV (conductive surfaces).

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 29 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.2.3 Indirect Electrostatic Discharge Test - Vertical Coupling Plane

For indirect electrostatic discharges, the vertical coupling plane (0.5 m x 0.5 m) was tied to the
ground reference plane through braid and a series of two 470 k resistors one at each end of the
braid.

Please see section 6.2 of this report for mounting, bonding and grounding of the EUT. The EUT was
operated and configured as described in section 4.2 of this report. The EUT was set up as shown in
Appendix D of this report. Photographs of the test equipment and EUT setup during the test are in
Appendix D. The data sheets are in Appendix E.

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. A distance of one
meter was maintained between the EUT and the shield room walls or any other metallic structures.
The ground strap of the ESD generator was connected to the earth ground (shield room ground
reference plane) and was a minimum of 0.2 m away from the EUT. The coupling plane was placed
0.1 meters from each side of the EUT, and at a height close to the center of the EUT. The discharges
were applied to the edge of the VCP. Ten discharges were applied to the VCP at each test level in
each polarity on each side of the unit. After completion of the test, a functional test was performed on
the EUT to ensure proper operation.

Test Results:

The EUT complies with the relevant requirements of EN55024 as per the requirements described in
EN61000-4-2. The unit operates within the specifications for indirect discharges to the VCP at 2.0
kV 4.0 kV, and 8kV.

7.2.4 Indirect Electrostatic Discharge Test - Horizontal Coupling Plane

For indirect electric discharges the horizontal coupling plane (1.0 m x 1.0 m) was tied to the ground
reference plane through braid and a series of two 470 k resistors at each end of the braid.

Please see section 6.2 of this report for mounting, bonding and grounding of the EUT. The EUT was
operated and configured as described in section 4.2 of this report. The EUT was set up as shown in
Appendix D of this report. Photographs of the test equipment and EUT setup during the test are in
Appendix D. The data sheets are in Appendix E.

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. A distance of one
meter was maintained between the EUT and the shield room walls or any other metallic structures.
The ground strap of the ESD generator was connected to the earth ground (shield room ground
reference plane) and was a minimum of 0.2 m away from the EUT. The discharges were applied to
the center of the front edge of the HCP 10cm in front of the EUT at each test level in each polarity.
After completion of the test, a functional test was performed on the EUT to ensure proper operation.

Test Results:

The EUT complies with the relevant requirements of EN55024 as per the requirements described in
EN61000-4-2. The unit operates within the specifications for indirect discharges to the HCP at 2.0
kV 4.0 kV, and 8kV.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 30 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.3 Radio-Frequency Electromagnetic Field

For this test, the Hybrid Log Periodic was used to radiate the energy onto the EUT at the specified
test level. The field uniformity was established by means of the computer software program prior to
the test and without injecting modulation. The transmitting antenna was placed in a fixed location
and distance during both calibration and test.

Please see section 6.2 of this report for mounting, bonding, and grounding of the EUT. The EUT was
operated and configured as described in section 4.2 of this report. The EUT was set up as shown in
Appendix D of this report. Photographs of the test equipment and EUT setup during the test are
included in Appendix D. The data sheets are located in Appendix E.

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. The RF energy was
radiated using the hybrid log from 80 - 2000 MHz. The signal was amplitude modulated at 80% with
a 1 kHz sine wave for the entire frequency range. The frequency was adjusted by 1% increments
beginning with the start frequency and increasing by 1% of each subsequent frequency, the dwell
time was 1 sec. In certain cases the dwell time may be extended due to the operating duty cycle of the
EUT, but in any event, the dwell time is sufficiently long to encompass the entire duty cycle of the
EUT.

A solitary probe was placed next to the EUT for field verification only. The computer software
program performed the test. After completion of the test, a functional test was performed on the EUT
to ensure proper operation.

Test Results:

The EUT complies with the relevant requirements of EN55024 as per the test procedures described in
EN 61000-4-3. The unit operates within the specifications.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 31 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.4 Fast Transient Common Mode Tests

The test was performed as per EN 61000-4-4. The burst duration was 15 ms, with 300 ms burst
period. The individual impulse had a 5ns rise time and a 50ns decay time and a 5 kHz frequency up
to 2 kV, and a 2.5 kHz frequency above 2 kV. The EMC immunity test system was used for the test.
Please see section 6.2 of this report for mounting, bonding, and grounding of the EUT. The EUT was
operated and configured as described in section 4.2 of this report. The coupling/decoupling network
was placed 0.5 meter away from the EUT. The EUT was set up as shown in Appendix D of this
report. Photographs of the test equipment and EUT setup during the test are included in Appendix D.
7.4.1 Power Lines

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. The transient
energy was injected onto the power line through the use of a coupling/decoupling network. Bursts of
pulse trains were injected onto the power line, in both positive and negative polarities. The test level
was 0.5 kV and 1.0 kV. The test was run for one minute on each lead and each lead combination.
After completion of the test, a functional test was performed on the EUT to ensure proper operation.

Test Results:

The EUT complies with the relevant requirements of EN55024 as per the test procedures described in
EN 61000-4-4. The unit operates within specifications during and after bursts of transients of 0.5
kV and 1.0 kV on power lines.
7.4.2 Data Lines

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. The transient
energy was coupled from the EMC immunity test system to the signal lines through the use of the
capacitive coupling clamp. The clamp meets the requirements of EN 61000-4-4. The clamp was
placed on the ground plane, and the data lines were placed inside the clamp. Bursts of pulse trains
were injected onto the signal lines, in both positive and negative polarities. The test level was 0.5
kV. The test was run for one minute on each cable. After completion of the test, a functional test was
performed on the EUT to ensure proper operation.

Test Results:

The EUT complies with the relevant requirements of EN55024 as per the test procedures described in
EN 61000-4-4. The unit operates within specifications during and after bursts of transients of 0.5
kV on data lines.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 32 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.5 Surge Immunity Test

Power Lines

The EMC Test Immunity System was used to provide the "Combination Wave" as specified in EN
61000-4-5 Voltage waveform for high impedance - Rise time to crest voltage: 1.2 uS approx. and
Decay: 50 uS to 50% of peak voltage value. Current waveform for low impedance - Rise time to crest
voltage: 8.0 uS approx. and Decay: 20 uS to 50% of peak current value. The amplitude was increased
incrementally at the stated test levels contained in EN 61000-4-5 using the EMC Test Immunity
System software, which was installed on the desktop computer. As per EN 61000-4-5, the selection
of the voltage or current waveform depends on impedance offered by the EUT.

Test Results:

The EUT complies with the requirements of EN55024 as per the test procedures described in EN
61000-4-5. The unit operates within its specifications before and after Common mode Surges of 
2.0 kV and Differential mode surges of  1.0 kV on power lines.

Telecommunication Lines

Test Results:
The EUT has no telecommunication cables that connect directly to outdoor cables; therefore this test
was deemed unnecessary and thus was not performed. Had this test been applicable it would have
been performed as described below.

The EMC Test Immunity System was used to provide the "Combination Wave" as specified in EN
61000-4-5 Voltage waveform for high impedance - Rise time to crest voltage: 1.2 uS approx. and,
Decay: 50 uS to 50% of peak voltage value. Current waveform for low impedance - Rise time to crest
voltage: 8.0 uS approx. and, Decay: 20 uS to 50% of peak current value. The amplitude was
increased incrementally at the stated test levels contained in EN 61000-4-5 using the EMC Test
Immunity System software, which was installed on the desktop computer. Surges were initiated on
the telecommunication line through the external coupler/decoupler module from the EMC Test
Immunity System. The telecommunication lines test was performed as per EN 61000-4-5.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 33 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.6 Conducted disturbances induced by RF Electromagnetic Field Test

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. This test was
performed as per EN 61000-4-6. For this test, a Coupling Decoupling Network was used to induce
an RF-field current directly onto the AC lines. The signal was 80% AM modulated with a 1 kHz sine
wave, with a field strength of 3Vrms, over the frequency range of 150 kHz to 80 MHz. The
frequency range was covered with a 1% step size and the dwell time was 1 second. The EUT was
placed 10 cm above the GRP with the Coupling Decoupling Network mounted and bonded to the
GRP.

The EUT was grounded through the AC power cord. The EUT was operated as described in section
4.2 of this report. The EUT was set up as shown in Appendix D of this report. Photographs of the
test equipment and EUT setup during the test are included in Appendix D.

Test Results:

The EUT complies with relevant requirements of EN55024 as per the test procedures described in EN
61000-4-6. The EUT operates within its specifications during exposure from 0.15 MHz - 80 MHz,
3Vrms with a 1 kHz sine wave AM modulation at 80%.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 34 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.7 Power Frequency Magnetic Field Test

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. This test was
performed to determine if the test sample was susceptible to Power Frequency Magnetic Fields which
are generated by power frequency current in conductors and leaking transformers. The test was
performed as per EN 61000-4-8. The magnetic field is applied by the immersion method to the EUT;
in this method the EUT is placed in the center of an induction coil. The waveform is that of the
typical power frequency either 50Hz or 60Hz. The Magnetic Field Strength is expressed in A/m; 1
A/m corresponds to free space induction of 1.26µTesla. A Square Induction coil, 1m by 1m with a
coupling plane placed under the EUT, was used to induce the magnetic field. The test duration was 1
minute for each of the three Orthogonal Axes.

The EUT was set up as shown in Appendix D of this report.

Test Results:

The EUT complies with requirements of EN55024 as per the test procedures described in EN 61000-
4-8. The unit operates within its specifications before; during, and after the Power Magnetic Field of
3 A/m was applied.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 35 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.8 Voltage Dips, Short Interruptions, and Voltage Variations

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation.
The EUT was also monitored during the test for any degradation of performance. This test was
performed as per EN61000-4-11. The purpose of this test was to determine the immunity of the EUT
when subjected to voltage dips, short interruptions, and voltage variations. The voltages of the EUT
were varied and disrupted at various levels of the supplied voltages for a given period of time. At
each level the test was performed 3 times. The voltage change-overs took place at zero degree
crossings.

The EUT was set up as shown in Appendix D of this report.

Test Results:

The EUT complies with requirements of EN55024 as per the test procedures described in EN 61000-
4-11. The unit operates within its specifications during and after voltage level reductions of >95% @
0.5 Period, 30% @ 30 Periods, and >95% @ 300 Periods.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 36 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

7.9 Quasi-Stationary Harmonics and Flicker Test

Test Results:

The EUT is rated under 75W and is unlikely to cause voltage fluctuation or flicker; therefore this test
was not performed. Had this test been applicable it would have been performed as described below.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page 37 of 37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

8. TEST PROCEDURE DEVIATIONS


There were no deviations from the test procedure.

9. CONCLUSIONS

The INTERNAL HARD DISK DRIVE, R/N: 800055, as tested, meets all of the Class B requirements
of the European Standards AS/NZS CISPR 32, ICES -003, VCCI, CNS13438, EN55032
(Electromagnetic compatibility of multimedia equipment – Emissions requirements) and EN55024
(Information Technology Equipment – Immunity Characteristics – Limits and Methods of
Measurement). Under paragraph G of section 15.109 of the Code of Federal Regulations Title 47,
Part 15, of the FCC Rules, the FCC accepts the international standards set forth in C.I.S.P.R.
Publication 22.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page A1
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

APPENDIX A

LABORATORY ACCREDITATIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page A2
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

LABORATORY ACCREDITATIONS AND


RECOGNITIONS
For US, Canada, Australia/New Zealand, Japan, Taiwan, Korea, and the European
Union, Compatible Electronics is currently accredited by NVLAP to ISO/IEC
17025. Please follow the link to the NIST/NVLAP site for each of our facilities'
NVLAP certificate and scope of accreditation

NVLAP listing links


Agoura Division / Brea Division / Silverado/Lake Forest Division

.Quote from ISO-ILAC-IAF Communiqué on 17025:

"A laboratory's fulfilment of the requirements of ISO/IEC 17025:2005 means the laboratory meets both
the technical competence requirements and management system requirements that are necessary for it to
consistently deliver technically valid test results and calibrations. The management system requirements
in ISO/IEC 17025:2005 (Section 4) are written in language relevant to laboratory operations and meet the
principles of ISO 9001:2008 Quality Management Systems — Requirements."

ANSI listing CETCB

Compatible Electronics has been nominated as a Conformity Assessment Body (CAB) for EMC under the
US/EU Mutual Recognition Agreement (MRA).
US/EU MRA list NIST MRA site

Compatible Electronics has been nominated as a Conformity Assessment Body (CAB) for Taiwan/BSMI
under the US/APEC (Asia-Pacific Economic Cooperation) Mutual Recognition Agreement (MRA).
APEC MRA list NIST MRA site

We are also listed for IT products by the following country/agency:

VCCI Support member: Please visit http://www.vcci.jp/vcci_e/

FCC Listing, from FCC OET site


FCC test lab search https://fjallfoss.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm

Compatible Electronics IC listing can be found at:


http://www.ic.gc.ca/eic/site/ic1.nsf/eng/home

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page B1
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

APPENDIX B

MODIFICATIONS TO THE EUT

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page B2
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

MODIFICATIONS TO THE EUT

There were no modifications made to the EUT.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page C1
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

APPENDIX C

ADDITIONAL MODELS COVERED


UNDER THIS REPORT

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page C2
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

ADDITIONAL MODELS COVERED


UNDER THIS REPORT
USED FOR THE PRIMARY TEST INTERNAL HARD DISK DRIVE
R/N: 800055
S/N: NONE

There were no additional models covered under this report.

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D1
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

APPENDIX D

DIAGRAMS, CHARTS AND PHOTOS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D2
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 1: CONDUCTED EMISSIONS TEST SETUP

EUT 80 cm away from SCREEN ROOM WALL


the LISNs.
Rear of table 40 cm
from wall.
Wooden Test Bench
(1x1.5 meters)
ACC EUT

ACC LISN EUT LISN

80 cm

TO EMI
RECEIVER

ACCESSORY EUT
POWER POWER

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D3
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 2: RADIATED EMISSIONS 3-METER


SEMI-ANECHOIC TEST CHAMBER

TURNTABLE
ANTENNA

3m

SEMI-ANECHOIC TEST CHAMBER

Mast, Antenna
Positioner

EMI Receiver

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D4
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 3: HIGH FREQUENCY TEST VOLUME

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D5
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 4: ELECTROSTATIC DISCHARGE

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D6
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 5: RADIATED SUSCEPTIBILITY SETUP

UNIFORM
WOODEN FIELD AREA
TEST BENCH

ANTENNA

ABSORBING
FERRITE

FERRITE TILES TO
REDUCE FLOOR
REFLECTIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D7
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 6: FAST TRANSIENTS COMMON MODE TEST SETUP

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D8
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 7: SURGE IMMUNITY TEST SETUP

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D9
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 8: CONDUCTED DISTURBANCES INDUCED BY RF


FIELDS TEST SETUP

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D10
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 9: POWER FREQUENCY MAGNETIC FIELD


TEST SETUP

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D11
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FIGURE 10: VOLTAGE DIPS & VOLTAGE VARIATIONS & SHORT


INTERRUPTIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D12
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

COM-POWER AC-220

LAB P - COMBILOG ANTENNA

S/N: 25857

CALIBRATION DUE: MAY 21, 2016


FREQUENCY (MHz) FACTOR FREQUENCY (MHz) FACTOR
(dB) (dB)
30 22.5 160 13.3
35 22.5 180 15.0
40 23.0 200 14.6
45 21.5 250 16.5
50 21.3 300 18.1
60 18.2 400 19.4
70 13.2 500 21.4
80 11.6 600 21.6
90 11.9 700 23.7
100 12.6 800 26.0
120 15.1 900 26.6
140 13.6 1000 28.5

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D13
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

COM-POWER AH-118

HORN ANTENNA

S/N: 071250

CALIBRATION DUE: JULY 1, 2016


FREQUENCY (MHz) FACTOR FREQUENCY (MHz) FACTOR
(dB) (dB)
1000 30.1 9500 44.2
1500 29.2 10000 43.4
2000 31.6 10500 44.6
2500 35.5 11000 45.1
3000 33.7 11500 45.7
3500 36.0 12000 46.2
4000 35.4 12500 45.4
4500 35.5 13000 44.8
5000 40.1 13500 46.7
5500 37.8 14000 47.8
6000 39.0 14500 46.4
6500 39.9 15000 47.2
7000 40.4 15500 45.5
7500 44.4 16000 45.0
8000 44.1 16500 44.5
8500 43.1 17000 47.0
9000 43.0 17500 47.8
18000 44.2

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D14
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

COM-POWER PAM-118

1-18GHz - PREAMPLIFIER

S/N: 443013

CALIBRATION DUE: APRIL 24, 2016

FREQUENCY FACTOR FREQUENCY FACTOR


(MHz) (dB) (MHz) (dB)
500 26.2 5500 25.3
1000 25.6 6000 25.0
1100 25.9 6500 24.7
1200 25.9 7000 23.6
1300 26.3 7500 23.3
1400 26.5 8000 23.7
1500 26.3 8500 24.0
1600 26.1 9000 24.3
1700 26.2 9500 24.1
1800 26.3 10000 23.7
1900 25.8 11000 24.2
2000 26.0 12000 23.2
2500 26.0 13000 22.8
3000 25.8 14000 22.6
3500 25.9 15000 22.9
4000 26.4 16000 22.3
4500 26.0 17000 22.6
5000 25.6 18000 23.9

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D15
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FRONT VIEW

WESTERN DIGITAL CORP.


INTERNAL HARD DISK DRIVE
R/N: 800055
EN 55032 CLASS B - RADIATED EMISSIONS – 4-22-2016

PHOTOGRAPH SHOWING THE EUT CONFIGURATION


FOR MAXIMUM EMISSIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D16
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

REAR VIEW
WESTERN DIGITAL CORP.
INTERNAL HARD DISK DRIVE
R/N: 800055
EN 55032 CLASS B - RADIATED EMISSIONS – 4-22-2016

PHOTOGRAPH SHOWING THE EUT CONFIGURATION


FOR MAXIMUM EMISSIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D17
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FRONT VIEW ABOVE 1 GHz

WESTERN DIGITAL CORP.


INTERNAL HARD DISK DRIVE
R/N: 800055
EN 55032 CLASS B - RADIATED EMISSIONS – 4-22-2016

PHOTOGRAPH SHOWING THE EUT CONFIGURATION


FOR MAXIMUM EMISSIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D18
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

REAR VIEW ABOVE 1 GHz

WESTERN DIGITAL CORP.


INTERNAL HARD DISK DRIVE
R/N: 800055
EN 55032 CLASS B - RADIATED EMISSIONS – 4-22-2016

PHOTOGRAPH SHOWING THE EUT CONFIGURATION


FOR MAXIMUM EMISSIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D19
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FRONT VIEW

WESTERN DIGITAL CORP.


INTERNAL HARD DISK DRIVE
R/N: 800055
EN 55032 CLASS B - CONDUCTED EMISSIONS – 4-22-2016

PHOTOGRAPH SHOWING THE EUT CONFIGURATION


FOR MAXIMUM EMISSIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D20
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

REAR VIEW

WESTERN DIGITAL CORP.


INTERNAL HARD DISK DRIVE
R/N: 800055
EN 55032 CLASS B - CONDUCTED EMISSIONS – 4-22-2016

PHOTOGRAPH SHOWING THE EUT CONFIGURATION


FOR MAXIMUM EMISSIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D21
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Pictures of 800055

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D22
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D23
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D24
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D25
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D26
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D27
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D28
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

ELECTROSTATIC DISCHARGE

COMPANY: WESTERN DIGITAL CORP. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


ELECTROSTATIC DISCHARGE TEST

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D29
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

ELECTROSTATIC DISCHARGE

COMPANY: WESTERN DIGITAL CORP. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


INDIRECT ELECTROSTATIC DISCHARGE TEST
(HORIZONTAL COUPLING PLANE)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D30
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

ELECTROSTATIC DISCHARGE

COMPANY: WESTERN DIGITAL CORP. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


INDIRECT ELECTROSTATIC DISCHARGE TEST
(VERTICAL COUPLING PLANE)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D31
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

RADIO-FREQUENCY ELECTROMAGNETIC FIELD

COMPANY: WESTERN DIGITAL CORP. DATE: 4-18-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


RADIO-FREQUENCY ELECTROMAGNETIC FIELDS TEST

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D32
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FAST TRANSIENTS COMMON MODE

COMPANY: WESTERN DIGITAL CORP. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


FAST TRANSIENT COMMON MODE TEST
(POWER LINES)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D33
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FAST TRANSIENTS COMMON MODE

COMPANY: WESTERN DIGITAL CORP. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


FAST TRANSIENT COMMON MODE TEST
(DATA LINES)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D34
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

SURGE IMMUNITY TEST

COMPANY: WESTERN DIGITAL CORP. DATE: 4-20-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


SURGE IMMUNITY TEST
(AC INPUT)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D35
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

CONDUCTED DISTURBANCES INDUCED BY RF FIELDS TEST

COMPANY: WESTERN DIGITAL CORP. DATE: 4-18-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


CONDUCTED DISTURBANCES INDUCED BY RF FIELDS
(POWER LINES)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D36
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

CONDUCTED DISTURBANCES INDUCED BY RF FIELDS TEST

COMPANY: WESTERN DIGITAL CORP. DATE: 4-18-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


CONDUCTED DISTURBANCES INDUCED BY RF FIELDS
(DATA LINES)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D37
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

POWER FREQUENCY MAGNETIC FIELD SUSCEPTIBILITY

COMPANY: WESTERN DIGITAL CORP. DATE: 4-20-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


POWER FREQUENCY MAGNETIC FIELD SUSCEPTIBILITY

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page D38
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

VOLTAGE DIPS & VOLTAGE VARIATIONS AND SHORT INTERRUPTIONS

COMPANY: WESTERN DIGITAL CORP. DATE: 2-1-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE

PHOTOGRAPH OF THE TEST SETUP FOR


VOLTAGE DIPS & VOLTAGE VARIATIONS AND SHORT INTERRUPTIONS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E1
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

APPENDIX E

DATA SHEETS

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E2
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

ELECTROSTATIC DISCHARGE

COMPANY: WESTERN DIGITAL. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 21 C
TEST PROC.: EN61000-4-2 TEMPERATURE:
LEVEL: ±2.0, ±4.0, ±6.0, ±8, ±12 & ±15.0 kV, BAROMETRIC 103.6 kPa
PRESSURE:
Direct
Air Discharges
PERFORMANCE B RELATIVE 53 %
CRITERIA: HUMIDITY:

TEST TEST POINT DESCRIPTION TEST TEST POINT DESCRIPTION


POINT POINT
A CD tray of host computer B CD LED of host computer
C Front ventilation grill of host computer D Front face of host computer
E Power button of host computer F Front headphone/microphone port of host
computer
G Back ports of host computer H Side panel handle of host computer

TEST POINTS LEVEL DISCHARGES NO. OF COMMENTS


(kV) PER FAILURES
POLARITY

A-H ±2.0 10 0 No Discharges Accepted

A-H ±4.0 10 0 No Discharges Accepted


A-H ±6.0 10 0 No Discharges Accepted
A-H ±8.0 10 0 No Discharges Accepted
A-H ±12.0 10 0 Meets Applicable Performance Criteria
A-H ±15.0 10 0 Meets Applicable Performance Criteria

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E3
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

ELECTROSTATIC DISCHARGE

COMPANY: WESTERN DIGITAL. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 21 C
TEST PROC.: EN61000-4-2 TEMPERATURE:
LEVEL: ±2.0, ±4.0 & ±8.0 kV Direct and Indirect BAROMETRIC 103.6 kPa
PRESSURE:
Contact Discharges
PERFORMANCE B RELATIVE 53 %
CRITERIA: HUMIDITY:

TEST TEST POINT DESCRIPTION TEST TEST POINT DESCRIPTION


POINT POINT
1 Top of host computer 2 Front handle of host computer
3 Back handle of host computer 4 Back ventilation panel of host computer
5 Right side of host computer 6 Left side of host computer

TEST POINTS LEVEL DISCHARGES NO. OF COMMENTS


(kV) PER FAILURES
POLARITY

±2.0 10 0 Meets applicable performance criteria

1-6 ±4.0 10 0 Meets applicable performance criteria


±8.0 10 0 Meets applicable performance criteria
±2.0 25 0 Meets applicable performance criteria
Horizontal ±4.0 25 0 Meets applicable performance criteria
Coupling Plane
±8.0 25 0 Meets applicable performance criteria
±2.0 25 0 Meets applicable performance criteria
Vertical ±4.0 25 0 Meets applicable performance criteria
Coupling Plane
±8.0 25 0 Meets applicable performance criteria

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E4
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

RADIO-FREQUENCY ELECTROMAGNETIC FIELD

COMPANY: WESTERN DIGITAL. DATE: 4-18-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 23 C
TEST PROC.: EN61000-4-3 TEMPERATURE:
LEVEL: 10 V/m, 1 kHz AM sine wave at 80% BAROMETRIC 102.1 kPa
PRESSURE:
PERFORMANCE A RELATIVE 45 %
CRITERIA: HUMIDITY:

ALL FOUR SIDES OF THE EUT WERE EXPOSED TO THE FIELDS.

FREQ. RANGE POLAR-. RESULT THRESHOLD COMMENTS


(MHz) IZATION (V/m)
80 - 2000 Horizontal Passed >10.0 V/m Meets applicable performance criteria

80 - 2000 Vertical Passed >10.0 V/m Meets applicable performance criteria

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E5
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

FAST TRANSIENTS COMMON MODE

COMPANY: WESTERN DIGITAL. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 21 C
TEST PROC.: EN61000-4-4 TEMPERATURE:
LEVEL:  0.5 & 1.0kV Power Lines BAROMETRIC 99.9 kPa
PRESSURE:
PERFORMANCE B RELATIVE 42 %
CRITERIA: HUMIDITY:

TEST LEVEL (kV) TEST DURATION (minutes) TIME BETWEEN TESTS (seconds)
1.0 1.0 10.0

AC ENTRY LEVEL RESULT COMMENTS


DESIGNATION (kV)
L1 ±0.5 Passed Meets applicable performance criteria
L1 ±1.0 Passed Meets applicable performance criteria

L2 ±0.5 Passed Meets applicable performance criteria


L2 ±1.0 Passed Meets applicable performance criteria

PE ±0.5 Passed Meets applicable performance criteria


PE ±1.0 Passed Meets applicable performance criteria

L1-L2-PE ±0.5 Passed Meets applicable performance criteria


L1-L2-PE ±1.0 Passed Meets applicable performance criteria

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E6
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

SURGE IMMUNITY TEST

COMPANY: WESTERN DIGITAL. DATE: 4-20-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 23 C
TEST PROC.: EN61000-4-5 TEMPERATURE:
LEVELS: 1.0 kV Differential Mode and 2.0 kV BAROMETRIC 102.1 kPa
Common Mode PRESSURE:
PERFORMANCE B RELATIVE 45 %
CRITERIA: HUMIDITY:

ENTRY PHASE ANGLE LEVEL RESULT COMMENTS


DESIGNATION (V)
L1 & L2 0 90 180 270 ±500 Passed Meets applicable performance criteria
L1 & L2 0 90 180 270 ±1000 Passed Meets applicable performance criteria

L1 & Ground 0 90 180 270 ±500 Passed Meets applicable performance criteria
L1 & Ground 0 90 180 270 ±1000 Passed Meets applicable performance criteria
L1 & Ground 0 90 180 270 ±2000 Passed Meets applicable performance criteria

L2 & Ground 0 90 180 270 ±500 Passed Meets applicable performance criteria
L2 & Ground 0 90 180 270 ±1000 Passed Meets applicable performance criteria
L2 & Ground 0 90 180 270 ±2000 Passed Meets applicable performance criteria

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E7
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

CONDUCTIVE DISTURBANCES
INDUCED BY RF ELECTROMAGNETIC FIELDS TEST

COMPANY: WESTERN DIGITAL. DATE: 4-18-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 23 C
TEST PROC.: EN 61000-4-6 TEMPERATURE:
LEVEL: 3Vrms, 1 kHz sine wave, BAROMETRIC 102.1 kPa
AM Modulation at 80% PRESSURE:
PERFORMANCE A RELATIVE 45 %
CRITERIA: HUMIDITY:

PORT ENTRY FREQ. RANGE RESULT THRESHOLD COMMENTS


(MHz) (V)
AC Mains .150 – 80 Passed 3.0 Meets applicable performance criteria

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E8
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

POWER-FREQUENCY MAGNETIC FIELD


SUSCEPTIBILITY

COMPANY: WESTERN DIGITAL. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 21 C
TEST PROC.: EN61000-4-8 TEMPERATURE:
LEVEL: 3 A/m, 50 and 60 Hz BAROMETRIC 99.9 kPa
PRESSURE:
PERFORMANCE A RELATIVE 42 %
CRITERIA: HUMIDITY:

ALL THREE ORTHOGONAL AXES WERE TESTED

ORTHOGONAL LEVEL RESULT COMMENTS


AXIS A/m
X 3 Passed Meets applicable performance criteria
Y 3 Passed Meets applicable performance criteria
Z 3 Passed Meets applicable performance criteria

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E9
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

VOLTAGE DIPS, SHORT INTERRUPTIONS, and VOLTAGE VARIATIONS

COMPANY: WESTERN DIGITAL. DATE: 4-19-2016


EUT: INTERNAL HARD DISK DRIVE ENGINEER: EUGENE ADAMS
R/N: 800055 S/N: NONE
SPEC.: EN55024 AIR 21 C
TEST PROC.: EN61000-4-11 TEMPERATURE:
LEVEL: >95% for 0.5 period, 30% for 30 periods, BAROMETRIC 99.9 kPa
PRESSURE:
>95% for 300 periods reduction
PERFORMANCE B AND C RELATIVE 42 %
CRITERIA: HUMIDITY:

TEST LEVEL (%) NUMBER OF TEST REPETITIONS TIME BETWEEN TESTS (seconds)
>95%, 30 % 3 10.0

DURATION LEVEL RESULT COMMENTS


(%)

0.5 period >95 Passed (short circuit) Meets applicable performance criteria

30 periods 30 Passed Meets applicable performance criteria

300 periods >95 Passed (open circuit) EUT resumed normal operation after

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E10
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/15/2016 5:08:56 PM


File: Radiated Final 30-1000Mhz2 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive: 800055.
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 71f
Hum: 46%
120V 60Hz

Compatible Electronics, Inc. FAC- 3 (LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E11
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/15/2016 5:08:56 PM


File: Radiated Final 30-1000Mhz2 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive: 800055.
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 71f
Hum: 46%
120V 60Hz

Compatible Electronics, Inc. 10m OATS (LAB P)

Frequency Q.P. Antenna Azimuth Antenna Cable Delta Spec

Height Factor Loss ** Limit


(MHz) (dBuV) (meters) (degrees) (dB) (dB) (dB) (dBuV)
30.70 -8.15 32.30 42.41 40.45 V 304.50 149.05
32.10 -12.39 28.06 38.10 40.45 V 252.00 99.35
48.20 -5.58 34.87 36.78 40.45 V 360.25 106.64
84.30 -5.84 34.61 36.33 40.45 V 117.75 180.52
96.30 -6.23 34.22 36.66 40.45 H 275.00 371.00
144.50 -12.84 27.61 31.57 40.45 H 209.75 232.00
879.40 -14.16 33.29 36.91 47.45 V 272.00 210.11

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E12
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 10:18:31 AM


File: Radiated Final 1-18GHz2 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive: 800055.
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 71f
Hum: 46%
120V 60Hz
No Emissions were found above 6GHz

Compatible Electronics, Inc. FAC- 3 (LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E13
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 10:18:31 AM


File: Radiated Final 1-18GHz2 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive: 800055.
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 71f
Hum: 46%
120V 60Hz
No Emissions were found above 6GHz

Compatible Electronics, Inc. FAC- 3 (LAB P)

(AVG) (AVG)EM
Limit (dB Ttbl Agl Transduce
Freq(MHz) Margi I Pol Twr Ht (cm)
V/m) (deg) r (dB)
n (dB) (dBµV/m)
1323.00 -3.29 46.71 50.00 H 313.00 181.41 29.69
2105.00 -14.58 35.42 50.00 H 10.25 128.64 32.76
2223.00 -13.65 36.35 50.00 H 280.25 103.82 33.78
2421.00 -8.37 41.63 50.00 H 298.25 128.05 35.35
2490.00 -7.98 42.02 50.00 H 17.25 106.41 35.87
2490.00 -9.22 40.78 50.00 V 61.00 104.11 35.88
2530.00 -9.69 40.31 50.00 H 313.25 106.94 35.80
2742.00 -10.85 39.15 50.00 H 360.00 160.35 34.76
3067.00 -14.60 39.40 54.00 V 290.50 99.70 34.01
3107.00 -17.56 36.44 54.00 H 26.25 130.88 34.24
3403.00 -14.70 39.30 54.00 H 19.25 128.52 35.91
3506.00 -14.49 39.51 54.00 V 267.00 212.11 36.42
3716.00 -14.84 39.16 54.00 H 319.00 146.88 36.17
4992.00 -9.83 44.17 54.00 H 325.75 163.00 40.05
5199.00 -10.68 43.32 54.00 V 197.75 200.58 39.54
5620.00 -10.74 43.26 54.00 V 234.50 182.70 38.86
5749.00 -10.42 43.58 54.00 H 272.75 350.00 39.02
5987.00 -8.79 45.21 54.00 H 343.50 219.88 39.32

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E14
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 7:15:44 PM


File: Conducted Final-Line_100 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
100V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E15
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 7:15:44 PM


File: Conducted Final-Line_100 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
100V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.43 -25.76 -17.22 21.49 40.03 47.25 57.25 0.07
0.45 -24.14 -15.86 22.81 41.09 46.95 56.95 0.07
0.47 -16.34 -13.53 30.18 42.98 46.51 56.51 0.07
0.48 -18.51 -14.07 27.87 42.31 46.37 56.37 0.07
0.49 -18.33 -13.35 27.91 42.89 46.24 56.24 0.07
0.49 -17.90 -12.42 28.20 43.68 46.10 56.10 0.07
0.94 -21.77 -20.80 24.23 35.20 46.00 56.00 0.07
1.15 -27.79 -20.50 18.21 35.50 46.00 56.00 0.07
1.16 -23.18 -19.74 22.82 36.26 46.00 56.00 0.07
1.17 -23.39 -18.51 22.61 37.49 46.00 56.00 0.07
1.18 -24.58 -18.63 21.42 37.37 46.00 56.00 0.07
1.24 -23.35 -15.84 22.65 40.16 46.00 56.00 0.07
1.53 -22.52 -17.27 23.48 38.73 46.00 56.00 0.07
1.60 -23.22 -19.48 22.78 36.52 46.00 56.00 0.07
1.68 -22.82 -17.73 23.18 38.27 46.00 56.00 0.07
1.70 -24.05 -18.43 21.95 37.57 46.00 56.00 0.07
1.71 -23.89 -19.48 22.11 36.52 46.00 56.00 0.07
1.97 -23.08 -21.20 22.92 34.80 46.00 56.00 0.07
2.48 -24.79 -19.68 21.21 36.32 46.00 56.00 0.07

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E16
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 7:31:07 PM


File: Conducted Final-Neutral_100 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
100V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E17
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 7:31:07 PM


File: Conducted Final-Neutral_100 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
100V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.47 -14.79 -11.75 31.66 44.70 46.44 56.44 0.03
0.49 -14.79 -10.58 31.44 45.66 46.24 56.24 0.03
0.49 -11.36 -10.55 34.74 45.55 46.10 56.10 0.03
0.51 -13.98 -12.18 32.02 43.82 46.00 56.00 0.03
0.65 -22.72 -16.69 23.28 39.31 46.00 56.00 0.01
0.96 -19.90 -14.08 26.10 41.92 46.00 56.00 0.00
1.01 -20.38 -14.22 25.62 41.78 46.00 56.00 0.00
1.15 -24.36 -16.76 21.64 39.24 46.00 56.00 0.00
1.18 -19.73 -13.41 26.27 42.59 46.00 56.00 0.00
1.19 -19.64 -12.48 26.36 43.52 46.00 56.00 0.00
1.20 -19.19 -12.11 26.81 43.89 46.00 56.00 0.00
1.21 -17.72 -11.25 28.28 44.75 46.00 56.00 0.00
1.23 -18.02 -11.38 27.98 44.62 46.00 56.00 0.00
1.23 -19.13 -11.25 26.87 44.75 46.00 56.00 0.00
1.25 -18.09 -12.66 27.91 43.34 46.00 56.00 0.00
1.27 -18.39 -13.03 27.61 42.97 46.00 56.00 0.00
1.51 -22.16 -16.92 23.84 39.08 46.00 56.00 0.01
1.63 -22.75 -19.84 23.25 36.16 46.00 56.00 0.01
1.64 -20.31 -16.39 25.69 39.61 46.00 56.00 0.01
1.65 -20.39 -14.69 25.61 41.31 46.00 56.00 0.01
1.68 -22.41 -15.74 23.59 40.26 46.00 56.00 0.01
1.71 -19.90 -13.18 26.10 42.82 46.00 56.00 0.01
1.74 -17.56 -11.35 28.44 44.65 46.00 56.00 0.01
1.77 -21.49 -14.79 24.51 41.21 46.00 56.00 0.01
1.77 -22.13 -15.53 23.87 40.47 46.00 56.00 0.01
1.82 -20.62 -15.81 25.38 40.19 46.00 56.00 0.01
1.91 -21.83 -16.07 24.17 39.93 46.00 56.00 0.01
1.93 -22.55 -15.45 23.45 40.55 46.00 56.00 0.01
1.95 -21.11 -14.12 24.89 41.88 46.00 56.00 0.01

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E18
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

1.96 -22.30 -13.78 23.70 42.22 46.00 56.00 0.01


1.98 -20.20 -14.26 25.80 41.74 46.00 56.00 0.01
2.03 -22.31 -16.86 23.69 39.14 46.00 56.00 0.01
2.43 -22.69 -16.10 23.31 39.90 46.00 56.00 0.01
2.45 -20.08 -14.47 25.92 41.53 46.00 56.00 0.01
2.47 -22.08 -13.54 23.92 42.46 46.00 56.00 0.01
2.60 -22.92 -16.45 23.08 39.55 46.00 56.00 0.01

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E19
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:43:49 PM


File: Conducted Final-Line_110 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
110V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E20
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:43:49 PM


File: Conducted Final-Line_110 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
110V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.46 -20.54 -16.20 26.12 40.45 46.66 56.66 0.07
0.49 -15.97 -16.05 30.27 40.19 46.24 56.24 0.07
0.49 -17.82 -16.99 28.28 39.11 46.10 56.10 0.07
0.50 -16.80 -16.93 29.20 39.07 46.00 56.00 0.07
0.51 -14.88 -13.87 31.12 42.13 46.00 56.00 0.07
0.52 -14.62 -11.77 31.38 44.23 46.00 56.00 0.07
0.53 -14.57 -13.14 31.43 42.86 46.00 56.00 0.07
0.67 -21.79 -17.65 24.21 38.35 46.00 56.00 0.07
0.79 -19.31 -19.90 26.69 36.10 46.00 56.00 0.07
1.00 -21.08 -17.69 24.92 38.31 46.00 56.00 0.07
1.01 -19.94 -17.40 26.06 38.60 46.00 56.00 0.07
1.03 -19.16 -17.41 26.84 38.59 46.00 56.00 0.07
1.05 -18.44 -16.36 27.56 39.64 46.00 56.00 0.07
1.06 -18.20 -16.11 27.80 39.89 46.00 56.00 0.07
1.07 -18.21 -16.55 27.79 39.45 46.00 56.00 0.07
1.09 -19.47 -17.67 26.53 38.33 46.00 56.00 0.07
1.20 -22.05 -23.05 23.95 32.95 46.00 56.00 0.07
1.25 -22.22 -19.21 23.78 36.79 46.00 56.00 0.07
1.27 -20.85 -19.01 25.15 36.99 46.00 56.00 0.07
1.29 -21.47 -17.83 24.53 38.17 46.00 56.00 0.07
1.30 -21.39 -18.73 24.61 37.27 46.00 56.00 0.07
1.32 -21.42 -18.51 24.58 37.49 46.00 56.00 0.07
1.76 -16.34 -14.20 29.66 41.80 46.00 56.00 0.07
1.77 -19.04 -18.91 26.96 37.09 46.00 56.00 0.07
1.85 -20.09 -19.35 25.91 36.65 46.00 56.00 0.07
1.88 -20.95 -18.95 25.05 37.05 46.00 56.00 0.07
2.03 -20.62 -21.66 25.38 34.34 46.00 56.00 0.07
2.19 -22.04 -23.23 23.96 32.77 46.00 56.00 0.07
2.63 -21.34 -21.37 24.66 34.63 46.00 56.00 0.07

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E21
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:54:07 PM


File: Conducted Final-Neutral_110 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
110V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E22
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:54:07 PM


File: Conducted Final-Neutral_110 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
110V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.34 -20.05 -14.21 29.10 44.95 49.15 59.15 0.04
0.47 -18.29 -16.12 28.22 40.39 46.51 56.51 0.03
0.49 -17.81 -16.76 28.29 39.34 46.10 56.10 0.03
0.52 -14.19 -11.83 31.81 44.17 46.00 56.00 0.03
0.83 -16.77 -14.80 29.23 41.20 46.00 56.00 0.00
1.04 -18.55 -16.53 27.45 39.47 46.00 56.00 0.00
1.05 -18.00 -15.84 28.00 40.16 46.00 56.00 0.00
1.07 -17.98 -15.37 28.02 40.63 46.00 56.00 0.00
1.13 -17.64 -17.12 28.36 38.88 46.00 56.00 0.00
1.14 -17.40 -17.05 28.60 38.95 46.00 56.00 0.00
1.16 -15.78 -13.82 30.22 42.18 46.00 56.00 0.00
1.17 -12.73 -8.88 33.27 47.12 46.00 56.00 0.00
1.62 -20.81 -19.62 25.19 36.38 46.00 56.00 0.01
1.77 -17.56 -16.51 28.44 39.49 46.00 56.00 0.01
2.62 -21.23 -21.13 24.77 34.87 46.00 56.00 0.01

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E23
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:27:54 PM


File: Conducted Final-Line_220 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
220V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E24
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:27:54 PM


File: Conducted Final-Line_220 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
220V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.39 -27.38 -15.53 20.60 42.45 47.98 57.98 0.07
0.41 -21.67 -15.80 25.97 41.85 47.65 57.65 0.07
0.43 -22.73 -14.69 24.60 42.64 47.33 57.33 0.07
0.44 -21.78 -12.31 25.32 44.79 47.10 57.10 0.07
0.45 -20.94 -10.33 25.86 46.48 46.80 56.80 0.07
0.47 -18.81 -9.31 27.70 47.20 46.51 56.51 0.07
0.48 -18.86 -9.42 27.44 46.88 46.30 56.30 0.07
0.49 -18.15 -9.43 27.95 46.67 46.10 56.10 0.07
0.51 -15.42 -8.27 30.58 47.73 46.00 56.00 0.07
0.53 -14.75 -7.64 31.25 48.36 46.00 56.00 0.07
0.55 -11.09 -5.79 34.91 50.21 46.00 56.00 0.07
0.56 -9.87 -5.71 36.13 50.29 46.00 56.00 0.07
0.57 -8.37 -4.60 37.63 51.40 46.00 56.00 0.07
0.60 -15.24 -9.11 30.76 46.89 46.00 56.00 0.07
0.61 -13.83 -7.51 32.17 48.49 46.00 56.00 0.07
0.61 -16.67 -6.14 29.33 49.86 46.00 56.00 0.07
0.61 -17.61 -7.52 28.39 48.48 46.00 56.00 0.07
0.63 -18.46 -12.02 27.54 43.98 46.00 56.00 0.07
0.64 -21.83 -12.75 24.17 43.25 46.00 56.00 0.07
0.65 -21.26 -11.37 24.74 44.63 46.00 56.00 0.07
0.67 -21.33 -11.71 24.67 44.29 46.00 56.00 0.07
0.68 -21.31 -11.82 24.69 44.18 46.00 56.00 0.07
0.69 -21.22 -11.72 24.78 44.28 46.00 56.00 0.07
0.71 -21.36 -11.58 24.64 44.42 46.00 56.00 0.07
0.73 -20.52 -11.54 25.48 44.46 46.00 56.00 0.07
0.73 -21.28 -11.41 24.72 44.59 46.00 56.00 0.07
0.76 -21.07 -12.17 24.93 43.83 46.00 56.00 0.07
0.78 -20.33 -11.81 25.67 44.19 46.00 56.00 0.07
0.79 -19.80 -12.54 26.20 43.46 46.00 56.00 0.07

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E25
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

0.80 -18.85 -12.97 27.15 43.03 46.00 56.00 0.07


0.82 -18.68 -13.47 27.32 42.53 46.00 56.00 0.07
0.84 -16.28 -13.70 29.72 42.30 46.00 56.00 0.07
0.86 -14.77 -10.61 31.23 45.39 46.00 56.00 0.07
0.87 -17.79 -12.03 28.21 43.97 46.00 56.00 0.07
0.88 -21.31 -13.21 24.69 42.79 46.00 56.00 0.07
0.90 -23.04 -12.99 22.96 43.01 46.00 56.00 0.07
0.91 -23.01 -12.90 22.99 43.10 46.00 56.00 0.07
0.93 -23.16 -12.97 22.84 43.03 46.00 56.00 0.07
0.94 -23.54 -13.51 22.46 42.49 46.00 56.00 0.07
0.96 -23.84 -14.03 22.16 41.97 46.00 56.00 0.07
0.97 -22.36 -14.83 23.64 41.17 46.00 56.00 0.07
0.99 -24.00 -15.22 22.00 40.78 46.00 56.00 0.07
1.00 -22.70 -14.57 23.30 41.43 46.00 56.00 0.07
1.02 -22.37 -15.74 23.63 40.26 46.00 56.00 0.07
1.05 -20.70 -16.63 25.30 39.37 46.00 56.00 0.07
1.14 -17.82 -15.80 28.18 40.20 46.00 56.00 0.07
1.43 -19.41 -15.33 26.59 40.67 46.00 56.00 0.07
2.31 -19.17 -15.50 26.83 40.50 46.00 56.00 0.07
2.54 -20.37 -18.84 25.63 37.16 46.00 56.00 0.07
2.59 -19.84 -15.62 26.16 40.38 46.00 56.00 0.07
2.59 -19.67 -15.06 26.33 40.94 46.00 56.00 0.07
2.82 -22.68 -20.87 23.32 35.13 46.00 56.00 0.07
2.89 -19.98 -15.11 26.02 40.89 46.00 56.00 0.07
4.20 -24.17 -25.44 21.83 30.56 46.00 56.00 0.07

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E26
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:10:21 PM


File: Conducted Final-Neutral_220 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
220V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E27
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 6:10:21 PM


File: Conducted Final-Neutral_220 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
220V 60Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.39 -26.31 -14.57 21.76 43.49 48.06 58.06 0.03
0.42 -22.12 -15.14 25.29 42.27 47.41 57.41 0.03
0.43 -21.88 -12.69 25.30 44.48 47.18 57.18 0.03
0.45 -20.46 -10.46 26.42 46.42 46.88 56.88 0.03
0.47 -18.48 -9.58 28.10 47.00 46.58 56.58 0.03
0.48 -18.75 -9.40 27.56 46.91 46.30 56.30 0.03
0.49 -18.05 -9.37 28.05 46.73 46.10 56.10 0.03
0.51 -15.68 -8.29 30.32 47.71 46.00 56.00 0.03
0.52 -15.29 -7.92 30.71 48.08 46.00 56.00 0.03
0.54 -13.29 -7.14 32.71 48.86 46.00 56.00 0.02
0.55 -11.62 -6.08 34.38 49.92 46.00 56.00 0.02
0.56 -9.39 -6.42 36.61 49.58 46.00 56.00 0.02
0.57 -8.97 -5.24 37.03 50.76 46.00 56.00 0.02
0.57 -8.83 -4.83 37.17 51.17 46.00 56.00 0.02
0.58 -10.41 -7.28 35.59 48.72 46.00 56.00 0.02
0.59 -14.35 -9.80 31.65 46.20 46.00 56.00 0.02
0.60 -16.13 -8.69 29.87 47.31 46.00 56.00 0.02
0.61 -12.57 -6.22 33.43 49.78 46.00 56.00 0.02
0.62 -19.27 -13.45 26.73 42.55 46.00 56.00 0.01
0.64 -21.96 -12.99 24.04 43.01 46.00 56.00 0.01
0.65 -22.12 -11.40 23.88 44.60 46.00 56.00 0.01
0.67 -20.96 -11.77 25.04 44.23 46.00 56.00 0.01
0.68 -21.26 -11.86 24.74 44.14 46.00 56.00 0.01
0.69 -21.24 -11.75 24.76 44.25 46.00 56.00 0.01
0.71 -21.39 -11.66 24.61 44.34 46.00 56.00 0.00
0.72 -20.93 -11.59 25.07 44.41 46.00 56.00 0.00
0.73 -21.00 -11.33 25.00 44.67 46.00 56.00 0.00
0.75 -21.23 -11.96 24.77 44.04 46.00 56.00 0.00

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E28
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

0.76 -21.06 -12.17 24.94 43.83 46.00 56.00 0.00


0.77 -20.17 -12.07 25.83 43.93 46.00 56.00 0.00
0.78 -20.09 -11.89 25.91 44.11 46.00 56.00 0.00
0.79 -20.73 -12.48 25.27 43.52 46.00 56.00 0.00
0.79 -20.06 -12.81 25.94 43.19 46.00 56.00 0.00
0.80 -19.26 -13.05 26.74 42.95 46.00 56.00 0.00
0.82 -18.80 -13.41 27.20 42.59 46.00 56.00 0.00
0.83 -16.75 -12.52 29.25 43.48 46.00 56.00 0.00
0.84 -17.46 -13.80 28.54 42.20 46.00 56.00 0.00
0.86 -15.13 -10.86 30.87 45.14 46.00 56.00 0.00
0.87 -16.75 -11.47 29.25 44.53 46.00 56.00 0.00
0.88 -20.92 -13.40 25.08 42.60 46.00 56.00 0.00
0.89 -22.52 -13.14 23.48 42.86 46.00 56.00 0.00
0.91 -22.61 -12.71 23.39 43.29 46.00 56.00 0.00
0.93 -22.82 -12.96 23.18 43.04 46.00 56.00 0.00
0.94 -23.40 -13.96 22.60 42.04 46.00 56.00 0.00
0.95 -23.83 -13.90 22.17 42.10 46.00 56.00 0.00
0.97 -22.18 -15.30 23.82 40.70 46.00 56.00 0.00
0.98 -23.89 -15.59 22.11 40.41 46.00 56.00 0.00
1.00 -22.45 -14.25 23.55 41.75 46.00 56.00 0.00
1.01 -22.14 -15.64 23.86 40.36 46.00 56.00 0.00
1.03 -20.46 -15.55 25.54 40.45 46.00 56.00 0.00
1.06 -19.78 -16.57 26.22 39.43 46.00 56.00 0.00
1.15 -17.82 -13.49 28.18 42.51 46.00 56.00 0.00
1.43 -19.12 -15.44 26.88 40.56 46.00 56.00 0.01
2.58 -19.95 -17.29 26.05 38.71 46.00 56.00 0.01
2.61 -20.54 -17.12 25.46 38.88 46.00 56.00 0.01
2.89 -20.87 -15.93 25.13 40.07 46.00 56.00 0.01
4.32 -24.78 -20.98 21.22 35.02 46.00 56.00 0.01

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E29
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 5:22:41 PM


File: Conducted Final-Line_230 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
230V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E30
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 5:22:41 PM


File: Conducted Final-Line_230 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
230V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.39 -26.72 -14.86 21.26 43.12 47.98 57.98 0.07
0.41 -19.54 -14.94 28.03 42.63 47.57 57.57 0.07
0.46 -20.93 -10.31 25.80 46.42 46.73 56.73 0.07
0.48 -20.96 -10.58 25.41 45.80 46.37 56.37 0.07
0.49 -19.10 -9.78 27.07 46.38 46.17 56.17 0.07
0.50 -18.56 -9.21 27.47 46.82 46.03 56.03 0.07
0.51 -16.97 -8.59 29.03 47.41 46.00 56.00 0.07
0.52 -16.23 -8.06 29.77 47.94 46.00 56.00 0.07
0.53 -14.50 -7.38 31.50 48.62 46.00 56.00 0.07
0.55 -13.17 -6.53 32.83 49.47 46.00 56.00 0.07
0.56 -12.17 -5.88 33.83 50.12 46.00 56.00 0.07
0.57 -11.58 -5.90 34.42 50.10 46.00 56.00 0.07
0.57 -13.80 -6.14 32.20 49.86 46.00 56.00 0.07
0.59 -15.94 -9.67 30.06 46.33 46.00 56.00 0.07
0.61 -12.39 -4.42 33.61 51.58 46.00 56.00 0.07
0.62 -9.95 -3.51 36.05 52.49 46.00 56.00 0.07
0.64 -15.44 -8.29 30.56 47.71 46.00 56.00 0.07
0.66 -19.97 -12.28 26.03 43.72 46.00 56.00 0.07
0.67 -21.24 -12.46 24.76 43.54 46.00 56.00 0.07
0.68 -22.68 -12.62 23.32 43.38 46.00 56.00 0.07
0.69 -23.05 -12.68 22.95 43.32 46.00 56.00 0.07
0.70 -23.74 -12.58 22.26 43.42 46.00 56.00 0.07
0.71 -23.24 -12.36 22.76 43.64 46.00 56.00 0.07
0.73 -22.82 -12.05 23.18 43.95 46.00 56.00 0.07
0.74 -22.22 -11.96 23.78 44.04 46.00 56.00 0.07
0.75 -20.77 -11.62 25.23 44.38 46.00 56.00 0.07
0.77 -21.68 -12.05 24.32 43.95 46.00 56.00 0.07
0.77 -20.40 -11.85 25.60 44.15 46.00 56.00 0.07

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E31
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

0.78 -19.49 -11.42 26.51 44.58 46.00 56.00 0.07


0.80 -18.56 -11.84 27.44 44.16 46.00 56.00 0.07
0.81 -18.12 -12.12 27.88 43.88 46.00 56.00 0.07
0.82 -16.31 -12.14 29.69 43.86 46.00 56.00 0.07
0.84 -15.47 -12.22 30.53 43.78 46.00 56.00 0.07
0.85 -17.35 -13.07 28.65 42.93 46.00 56.00 0.07
0.87 -20.23 -14.39 25.77 41.61 46.00 56.00 0.07
0.87 -21.70 -14.01 24.30 41.99 46.00 56.00 0.07
0.89 -23.91 -13.27 22.09 42.73 46.00 56.00 0.07
0.90 -23.26 -12.56 22.74 43.44 46.00 56.00 0.07
0.92 -24.70 -12.53 21.30 43.47 46.00 56.00 0.07
0.93 -24.61 -13.61 21.39 42.39 46.00 56.00 0.07
0.94 -25.20 -13.95 20.80 42.05 46.00 56.00 0.07
0.95 -25.79 -14.61 20.21 41.39 46.00 56.00 0.07
0.97 -25.14 -14.59 20.86 41.41 46.00 56.00 0.07
0.97 -23.55 -14.02 22.45 41.98 46.00 56.00 0.07
0.98 -24.74 -13.67 21.26 42.33 46.00 56.00 0.07
0.99 -23.08 -13.96 22.92 42.04 46.00 56.00 0.07
1.01 -22.08 -13.72 23.92 42.28 46.00 56.00 0.07
1.01 -22.38 -13.48 23.62 42.52 46.00 56.00 0.07
1.02 -22.08 -14.24 23.92 41.76 46.00 56.00 0.07
1.03 -20.12 -13.96 25.88 42.04 46.00 56.00 0.07
1.04 -19.68 -13.25 26.32 42.75 46.00 56.00 0.07
1.05 -19.24 -13.31 26.76 42.69 46.00 56.00 0.07
1.07 -18.93 -13.58 27.07 42.42 46.00 56.00 0.07
1.09 -19.24 -14.81 26.76 41.19 46.00 56.00 0.07
2.50 -21.99 -20.87 24.01 35.13 46.00 56.00 0.07
2.85 -22.73 -19.41 23.27 36.59 46.00 56.00 0.07
4.97 -26.54 -23.11 19.46 32.89 46.00 56.00 0.08

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E32
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 5:52:23 PM


File: Conducted Final-Neutral_230 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
230V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E33
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

Title: CISPR 22 Class B 4/22/2016 5:52:23 PM


File: Conducted Final-Neutral_230 Sequence: Final Measurements
Operator: Eugene Adams
EUT Type: Hard Disk Drive
EUT Condition: Running Read/Write Program.
Comments: Connected to PC. PC connected to KB/Mouse, Heaphones/Mic, and Router.
Temp: 73f
Hum: 49%
230V 50Hz

Compatible Electronics, Inc. FAC- 3 ( LAB P)

(AVG) (QP)
(AVG) (AVG) (QP)
Freq Margin Margin (QP) EMI Transduce
EMI Limit Limit
(MHz) AVL QPL (dBuV) r (dB)
(dBuV) (dBuV) (dBuV)
(dB) (dB)
0.37 -28.72 -15.86 19.69 42.55 48.41 58.41 0.03
0.39 -27.57 -14.99 20.49 43.07 48.06 58.06 0.03
0.41 -22.91 -15.47 24.82 42.26 47.73 57.73 0.03
0.42 -19.64 -14.78 27.85 42.71 47.49 57.49 0.03
0.43 -21.79 -14.45 25.46 42.80 47.25 57.25 0.03
0.44 -21.89 -11.69 25.14 45.33 47.02 57.02 0.03
0.45 -21.13 -10.27 25.67 46.53 46.80 56.80 0.03
0.46 -20.31 -10.19 26.34 46.47 46.66 56.66 0.03
0.47 -19.70 -10.33 26.82 46.19 46.51 56.51 0.03
0.48 -21.22 -10.56 25.16 45.82 46.37 56.37 0.03
0.49 -18.39 -9.45 27.71 46.65 46.10 56.10 0.03
0.51 -16.91 -8.57 29.09 47.43 46.00 56.00 0.03
0.52 -15.84 -8.09 30.16 47.91 46.00 56.00 0.03
0.53 -14.53 -7.32 31.47 48.68 46.00 56.00 0.03
0.54 -14.20 -7.35 31.80 48.65 46.00 56.00 0.02
0.55 -12.58 -6.39 33.42 49.61 46.00 56.00 0.02
0.57 -11.44 -5.97 34.56 50.03 46.00 56.00 0.02
0.57 -13.67 -7.04 32.33 48.96 46.00 56.00 0.02
0.59 -16.46 -10.29 29.54 45.71 46.00 56.00 0.02
0.61 -13.01 -4.62 32.99 51.38 46.00 56.00 0.02
0.62 -10.17 -3.62 35.83 52.38 46.00 56.00 0.01
0.63 -19.56 -6.98 26.44 49.02 46.00 56.00 0.01
0.64 -16.44 -9.47 29.56 46.53 46.00 56.00 0.01
0.65 -17.93 -12.33 28.07 43.67 46.00 56.00 0.01
0.67 -22.31 -12.63 23.69 43.37 46.00 56.00 0.01
0.69 -23.27 -12.61 22.73 43.39 46.00 56.00 0.01
0.71 -23.47 -12.55 22.53 43.45 46.00 56.00 0.00
0.73 -22.26 -11.97 23.74 44.03 46.00 56.00 0.00

20621 PASCAL WAY, LAKE FOREST, CALIFORNIA, 92630  PH: (949) 587-0400 FX: (949) 587-0476
Page E34
FCC, ICES-003, VCCI, CNS13438, AS/NZS CISPR 22, EN55032 & EN55024 Report Number: D60422Q3

0.74 -21.90 -11.93 24.10 44.07 46.00 56.00 0.00


0.77 -21.28 -12.13 24.72 43.87 46.00 56.00 0.00
0.78 -19.71 -11.49 26.29 44.51 46.00 56.00 0.00
0.80 -18.57 -11.99 27.43 44.01 46.00 56.00 0.00
0.81 -18.38 -12.45 27.62 43.55 46.00 56.00 0.00
0.82 -16.39 -12.08 29.61 43.92 46.00 56.00 0.00
0.83 -15.46 -12.41 30.54 43.59 46.00 56.00 0.00
0.83 -15.51 -12.21 30.49 43.79 46.00 56.00 0.00
0.84 -15.51 -12.30 30.49 43.70 46.00 56.00 0.00
0.84 -15.74 -12.95 30.26 43.05 46.00 56.00 0.00
0.87 -19.21 -14.41 26.79 41.59 46.00 56.00 0.00
0.88 -23.08 -13.51 22.92 42.49 46.00 56.00 0.00
0.89 -22.49 -13.62 23.51 42.38 46.00 56.00 0.00
0.91 -24.09 -12.73 21.91 43.27 46.00 56.00 0.00
0.92 -24.91 -13.66 21.09 42.34 46.00 56.00 0.00
0.93 -24.70 -13.59 21.30 42.41 46.00 56.00 0.00
0.94 -24.68 -13.59 21.32 42.41 46.00 56.00 0.00
0.95 -25.53 -14.56 20.47 41.44 46.00 56.00 0.00
0.98 -24.05 -13.90 21.95 42.10 46.00 56.00 0.00
0.99 -23.76 -13.96 22.24 42.04 46.00 56.00 0.00
1.00 -24.14 -13.61 21.86 42.39 46.00 56.00 0.00
1.01 -23.37 -14.02 22.63 41.98 46.00 56.00 0.00
1.03 -21.12 -13.74 24.88 42.26 46.00 56.00 0.00
1.04 -19.06 -13.63 26.94 42.37 46.00 56.00 0.00
1.07 -18.72 -13.47 27.28 42.53 46.00 56.00 0.00
1.15 -19.93 -15.06 26.07 40.94 46.00 56.00 0.00
1.36 -23.73 -18.84 22.27 37.16 46.00 56.00 0.00
1.58 -24.84 -19.14 21.16 36.86 46.00 56.00 0.01
2.99 -24.57 -21.36 21.43 34.64 46.00 56.00 0.01