You are on page 1of 6

QUESTION NUMBER SUB.CODE SUB.

NAME Dept-Year DATE TYPE

1 EE8501 PSA 3-EEE 1/22/2021 MC


2 EE8501 PSA 3-EEE 1/22/2021 MC
3 EE8501 PSA 3-EEE 1/22/2021 MC
4 EE8501 PSA 3-EEE 1/22/2021 MC
5 EE8501 PSA 3-EEE 1/22/2021 MC
6 EE8501 PSA 3-EEE 1/22/2021 MC
7 EE8501 PSA 3-EEE 1/22/2021 MC
8 EE8501 PSA 3-EEE 1/22/2021 MC
9 EE8501 PSA 3-EEE 1/22/2021 MC
10 EE8501 PSA 3-EEE 1/22/2021 MC
11 EE8501 PSA 3-EEE 1/22/2021 MC
12 EE8501 PSA 3-EEE 1/22/2021 MC
13 EE8501 PSA 3-EEE 1/22/2021 MC
14 EE8501 PSA 3-EEE 1/22/2021 MC
15 EE8501 PSA 3-EEE 1/22/2021 MC
16 EE8501 PSA 3-EEE 1/22/2021 MC
17 EE8501 PSA 3-EEE 1/22/2021 MC
18 EE8501 PSA 3-EEE 1/22/2021 MC
19 EE8501 PSA 3-EEE 1/22/2021 MC
20 EE8501 PSA 3-EEE 1/22/2021 MC
21 EE8501 PSA 3-EEE 1/22/2021 MC
22 EE8501 PSA 3-EEE 1/22/2021 MC
23 EE8501 PSA 3-EEE 1/22/2021 MC
24 EE8501 PSA 3-EEE 1/22/2021 MC
25 EE8501 PSA 3-EEE 1/22/2021 MC
26 EE8501 PSA 3-EEE 1/22/2021 MC
27 EE8501 PSA 3-EEE 1/22/2021 MC
28 EE8501 PSA 3-EEE 1/22/2021 MC
29 EE8501 PSA 3-EEE 1/22/2021 MC
30 EE8501 PSA 3-EEE 1/22/2021 MC
31 EE8501 PSA 3-EEE 1/22/2021 MC
32 EE8501 PSA 3-EEE 1/22/2021 MC
33 EE8501 PSA 3-EEE 1/22/2021 MC
34 EE8501 PSA 3-EEE 1/22/2021 MC
35 EE8501 PSA 3-EEE 1/22/2021 MC
36 EE8501 PSA 3-EEE 1/22/2021 MC
37 EE8501 PSA 3-EEE 1/22/2021 MC
38 EE8501 PSA 3-EEE 1/22/2021 MC
39 EE8501 PSA 3-EEE 1/22/2021 MC
40 EE8501 PSA 3-EEE 1/22/2021 MC
41 EE8501 PSA 3-EEE 1/22/2021 MC
42 EE8501 PSA 3-EEE 1/22/2021 MC
43 EE8501 PSA 3-EEE 1/22/2021 MC
44 EE8501 PSA 3-EEE 1/22/2021 MC
45 EE8501 PSA 3-EEE 1/22/2021 MC
QUESTION option1 option2 option3 option4 answer

  The domains of power system where directional overcurrent


In case ofrelay
par  In
is indispensable
case of ring
 Both
main
are
A and
feeder
 Both
B protection
A andoption3
B
 Which portion of the our system is least prone to faults?
Alternator Transforme Overhead lines
Undergrounoption1
Our system stability is least affected by Reactance of  Input torque
Losses Reactants ooption3
The critical clearing time of a fault is power system is Reactive poweShort circuiSteady-state
Transient stoption4
The over voltage surges in power systems me be causLightning Resonance Switching All of the option4
Swing curve provides information about Stability of t PerformancThe rotor All of theseoption1
Which among the following quantities are to be deterP and Q  Q and |V| |V| and δ Q and δ option4
The voltage of a particular bus can be controlled by coActive power  Reactive power
Phaseofangl
theAll
busof the option2
In power system, if a voltage controlled bus is treate Voltage Active powreactive p Phase angl option4
In power system, the maximum number of buses are Generator buLoad busesSlack busesP-V buses option2
On which among the following factors does the magniTotal impedanVoltage at tBoth (a) anNone of th option3
The positive sequence current of a transmission line i Always zero One third o Equal to negative
 three times
sequence
option3
the negative
current sequence c
Which among the following reactance have a greater Sub transient Transient r SynchronouAll of theseoption3
In which portion of the transmission system is the o Alternators TransformeTransmissioUndergrounoption3
What is the value of zero sequence impedance in line Zt0 = 1 Z0 = ∞ Z0 = 3 Zn Z0 = 0 option4
What percentage of fault occurring in the power system
5% 30% 25% 15% option4
What will be the sum of (I B + IY) in case of line to line fault,
∞ if the fault
0 is occurring
1 in the B Iand
R
Y lines?option1
What happens to the value of the fault current in caseThe fault currThe fault c The fault c The fault c option4
What happens if the neutral is not grounded in case ofOnly the zero The zero seFault currenBoth (b) andoption4
What are cross country faults? A fault occurr  Two or more
Line
faults
to lineAll
occurring
of theseoption2
simultaneously on the powe
What percentage of faults occurring is single line to g 50% 60% 80% 70% option4
What are the types of unsymmetrical faults? Single line to Double lineLine to lineAll of theseoption4
A shunt fault is characterized by Increase in c Increase in Increase in None of th option2
What is the value of transient stability limit? Higher than stLower thanDepending
s Aull of theseoption2
In which type of fault, positive sequence and negativ  Line to line fault
Double lineLine to gro Symmetrical
option2
For the fault analysis in power system, symmetrical Results are r Sequence n Number ofAll
equations
of abov option2
becomes smaller
When a fault occurs in a power system the zero seque3-phase to gr Line to lineDouble lineLine to gro option2
Zero sequence current flows in a transmission line whDouble line to An over voltage
Line toinline
a line
 Fault
caused
across
by
option1
all
charged
the lines
load
Per unit system means A ratio of act A ratio of t Ratio of th All of theseoption1
On what factors does the transient stability depend oInitial operati Severity of Voltage instBoth (a) anoption4
In a load flow analysis of a power system, the load co  Constant current
Constant
drawni Voltage
from theand
bus
Constant reoption4
The Gauss-Seidel load flow method has following disa Unreliable convergence
Slow conveChoice of aA good initioption1
Compared to Gauss-Seidel method, Newton-RaphsonLess number oLess number
More number
More number
option1
Zero sequence impedance of the transmission line is equal to the About 2.5 tLess than pnone of th option2
A 50MVA ,10KV, 50Hz, star connected, unloaded three-ph
5 4 8 3 option1
A 50 Hz alternator is rated 500 MVA, 20 KV, with Xd = 7.22 6.4 3.22 2.2 option2
A single line to ground fault occurs on an unloaded generator
3.75 pu in phase
1.54a.pu
If Xd =
1.43
X2 =
pu0.25 1.25
pu, X0=
pu 0.15
option1
pu, reactance connecte
When a line-to-ground fault occurs, the current in a f zero 33.3 A 66.6 A 100 A option2
A power system is subjected to a fault which makes thDouble line toDouble lineLine of gro Three-phase
option2
A single line to ground fault occurs on a three-phase i√2V kV √3V kV 3V kV (1 ∕√3)V kVoption2
The zero sequence current of a generator for line to grj2.4 pu j0.8 pu j7.2 pu j0.24 pu option3
In which type of fault, all the three components Ia0, Ia1,
lineand
to groundline
Ia2 are equal
to line
Ia0 double lineNone of th option1
For a single line to ground fault the zero sequence currj1 pu  j3 pu j9 pu j6 pu option3
When a 50 MVA, 11 kV, 3-phase generator is subjected
j0.2
t pu and j0j0.2 pu andj0.25 pu an j0.05 pu and
option1
j0.05 pu
The positive sequence current for a line to line fault of62.75
the 2ΩkV system
4.52isΩ14005.27
A andΩ corresponding
0.52 Ω current
option4for a double line t
mark

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2