46NPS Negative Phase Sequence Overcurrent 81HBL2 Harmonic Block / Inrush Restraint
Two elements, one DTL and one IDMT, with user settings for Where second harmonic current is detected (i.e. during
pickup level and delays, will operate if NPS Current exceeds transformer energisation) user selectable elements can be
setting and delay. NPS Current elements can be used to de- blocked.
tect unbalances on the system or remote earth faults when a
delta-star transformer is in circuit. 51c Cold Load
If a circuit breaker is closed onto a ‘cold’ load, i.e. one that
49 Thermal Overload has not been powered for a prolonged period, this can im-
The thermal algorithm calculates the thermal states from the pose a higher than normal load-current demand on the sys-
measured currents and can be applied to lines, cables and tem which could exceed normal settings. These conditions
transformers. Outputs are available for thermal overload and can exist for an extended period and must not be interpreted
thermal capacity. as a fault. To allow optimum setting levels to be applied for
normal operation, the cold load pickup feature will apply
Function LED’s
Eight or sixteen user programmable tri-colour LED’s are
provided eliminating the need for expensive panel mounted
pilot lights and associated wiring. Each LED can be user set
to red, green or yellow allowing for clear indication of the
associated function’s state. A slip-in label pocket along-side
enables the user to insert customised notation. A printer
compatible template is available.
Function Keys
Six user programmable function keys are available for
implementing User logic and scheme control functionality,
eliminating the need for expensive panel mounted control
switches and associated wiring. Each function key has an
associated user programmable tri-color LED (red, green,
Siemens Protection Devices Limited 4
Additional Functionality Optional Functionality
27/59 Under/Over Voltage 79 Auto-Reclose
Each element has settings for pickup level, drop-off level and This function provides independent Phase fault and Earth
Definite Time Lag (DTL) delays. Operates if voltage ‘exceeds’ Fault/Sensitive Earth fault sequences of up to 5 Trips i.e. 4
setting for duration of delay. Can be applied in load shed- Reclose attempts before Lockout. Auto-Reclose sequence can
ding schemes. be user set to be initiated from internal protection operation
or via Binary Input from an external Protection. The user can
47 Negative Phase Sequence Overvoltage set each trip in the sequence to be either instantaneous
Each element has settings for pickup level and Definite Time (Fast) or delayed. Independent times can be set by the user
Lag (DTL) delays. Operates if NPS Voltage exceeds setting for for Reclose (Dead) time and Reclaim time.
duration of delay.
25 Check Sync
51V Voltage Controlled OverCurrent The check synchronizing function is used to check that the
Element has settings for UnderVoltage pickup level and voltage conditions, measured by the voltage transformers on
operates if voltage falls below setting. On Pick-up this either side of the open circuit breaker, indicate that it is safe
element applies the set 51v Multiplier to the pickup setting to close without risk of damage to the circuit breaker or
of the 67/51 phase fault elements. disturbance to the system.
Voltage Inputs
Quantity 4
Nominal Voltage 40…160 V a.c. Range
Instrumentation ≥ 0.8 xVn ±1% Vn
Thermal Withstand:
Continuous 300 V
1 Second
Burden @ 110 V £ 0.1 VA
DC Auxiliary supply
Type Limits
Insulation Quasi-peak Average
IEC 60255-5 0.15 to 0.5 MHz 79 dB(mV) 66 dB(mV)
0.5 to 30 MHz 73 dB(mV) 60 dB(mV)
Type Level
Between any terminal 2.0 kV AC RMS for 1 min Radiated Immunity
and earth IEC 60255-22-3 Class III
Between independent 2.0 kV AC RMS for 1 min
circuits Type Level Variation
80 MHz to 1000 MHz 10 V/m £ 5%
Across normally open 1.0 kV AC RMS for 1 min
contacts
Magnetic Field with Power Frequency
IEC 61000-4-8, Class V
High Frequency Disturbance
IEC 60255-22-1 Class III Type Level
100 A/m (0.126 mT) continuous 50 Hz
Type Level Variation 1000 A/m (1.26 mT) for 3s
Common 2.5 kV £ 5%
(longitudinal)
Series (transverse) 1.0 kV £ 5%
mode
Electrostatic Discharge
IEC 60255-22-2 Class IV
151.5
168
159
177
FOR ETHERNET
COMMS WIRING
CLEARANCE
75 mm MIN
Fig 3. E6 Case overall dimensions and panel drilling details (All dimensions in are mm)
Case Earth
201.5 11 31 216.5 connection 207.5
151.5
Typical
168
159
177
PANEL CUT-OUT when SIDE VIEW FRONT VIEW
fitted
FOR ETHERNET
COMMS WIRING
9.75 182
CLEARANCE
MINIMUM CLEARANCES:
75 mm MIN
NOTE:
THE 3.6 HOLES ARE FOR M4 THREAD FORMING (TRILOBULAR) SCREWS. THESE ARE SUPPLIED AS STANDARD AND ARE SUITABLE FOR USE IN FERROUS / ALUMINIUM PANELS
1.6mm THICK AND ABOVE. FOR OTHER PANELS, HOLES TO BE M4 CLEARANCE (TYPICALLY 4.5 DIAMETER) AND RELAYS MOUNTED USING M4 MACHINE SCREWS, NUTS AND
LOCKWASHERS (SUPPLIED IN PANEL FIXING KIT).
Fig 4. E8 Case overall dimensions and panel drilling details (All dimensions are in mm)
7SR21
+ve
2 3 1 2 1 2 1 2
-ve
BI 10 BO 9
4 1
+ve
6 7
-ve BI 11 BO 10 C B A Data
8 5
Comms
+ve Optional PSU Analogue
10 11 (Optional)
BI 12 BO 11 I/O
9
+ve
12 15
BI 13 BO 12 27 28 27 28 27 28
13
+ve
14 BO 13 17
BI 14 Rear View
BO 14 21 Arrangement of terminals and modules
+ve
16 19
-ve BI 15
18 BO 15 23
+ve
20 BO 16 27
BI 16
25
NOTES
+ve
22
BI 17 BI = Binary Input
BO = Binary Output
+ve
24
BI 18
+ve
26
Shows contacts internal to relay case
BI 19
28
-ve
C assembly.
Contacts close when the relay chassis is
1 withdrawn from case
+ve
22
-ve BO 1
24
3
28 GND.
5
BO 2 7
+ve
2 9
-ve BI 1
4 11
+ve
6 BO 3 13
-ve BI 2
8 15
+ve
10 17
-ve BI 3 BO 4
12 19
21
14 A BO 5
23
16 Screen
25
18 B
BO 6 26
20 Term.
B 27
1A +ve
1 18
BI 4
2 IL1
5A (IA) +ve
3 20
BI 5
4
1A +ve
5 22
BI 6 -ve
6 IL2 25
5A (IB)
7 +ve
24
8 BI 7
1A
9 +ve
26
10 IL3 BI 8
5A (IC)
11 +ve
28
12 BI 9 -ve
27
1A
13
19
14 BO 7
I4 (IG/ISEF) 17
5A
15
23
BO 8
16
A 21
Relay Type
0
1)
Case, I/O and Fascia
E6 case, 4 CT, 9 Binary Inputs, 8 Binary Outputs, 8 LEDs 2
E8 case, 4 CT, 19 Binary Inputs, 16 Binary Outputs, 16 LEDs 3
E8 case, 4 CT, 19 Binary Inputs, 16 Binary Outputs, 8 LEDs + 6 keys 4
Measuring input
1 A or 5 A, 50/60Hz 1
Auxiliary voltage
30 V to 220 V DC, binary input threshold 19 V DC A
30 V to 220 V DC, binary input threshold 88 V DC B
Spare
A
Communication Interface
Standard version - included in all models, USB front port, RS485 rear port 1
Standard version - plus additional rear F/O ST connectors (x2) and IRIG-B 2
Standard version - plus additional rear RS485 and IRIG-B 3
Standard version - plus additional rear RS232 and IRIG-B 4
Standard version - plus additional rear Electrical Ethernet RJ45 (x2) 7 7
Standard version - plus additional rear Optical Ethernet Duplex (x2) 8 7
Protocol
IEC 60870-5-103 and Modbus RTU (user selectable) 1
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable) 2
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable) and IEC61850 7-8 7
Spare
0
Additional Functionality
No additional functionality A
Spare
0
1)
4CT is configured as 3PF + EF/SEF (user selectable setting).
Export Data
HS: 8536900
ECCN: N
AL: N
Relay Type
0
1)
Case, I/O and Fascia
E6 case, 5 CT, 4 VT, 3 Binary Inputs, 6 Binary Outputs, 8 LEDs 2 C
E8 case, 5 CT, 4 VT, 13 Binary Inputs, 14 Binary Outputs, 16 LEDs 3
E8 case, 5 CT, 4 VT, 13 Binary Inputs, 14 Binary Outputs, 8 LEDs + 6 keys 4
Measuring input
1 A or 5 A, 40 V to 160 V, 50/60Hz 2
Auxiliary voltage
30 V to 220 V DC, binary input threshold 19 V DC A
30 V to 220 V DC, binary input threshold 88 V DC B
Spare
A
Communication Interface
Standard version - included in all models, USB front port, RS485 rear port 1
Standard version - plus additional rear F/O ST connectors (x2) and IRIG-B 2
Standard version - plus additional rear RS485 and IRIG-B 3
Standard version - plus additional rear RS232 and IRIG-B 4
Standard version - plus additional rear Electrical Ethernet RJ45 (x2) 7 7
Standard version - plus additional rear Optical Ethernet Duplex (x2) 8 7
Protocol
IEC 60870-5-103 and Modbus RTU (user selectable) 1
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable) 2
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable) and IEC61850 7-8 7
Spare
0
Additional Functionality
No additional functionality A
Spare
0
1)
5CT is configured as 3PF + EF/SEF + EF/SEF (user selectable setting).
Export Data
HS: 8536900
ECCN: N
AL: N