Professional Documents
Culture Documents
1. Frame types
2. Cable types
3. Strength 275 N/mm2
4. Modulus Elasticity 205 N/mm2
DIMENSION
1. Tower Height Ht = 25 m
2. Cable height h1 = 15 m
h2 = 10 m
3. Cable leg distance Ll = 5 m
4. Cable Length Lc1 = 25.495098 m
Fx3 Fx2 Lc2 = 15.811388 m
LOADING
120
1. Lateral Load Fx = 30.85 KN
120 120 2. Overturning moment Mo = 771.25 KNm
3. Horizontal force to joint b Fjb = 13.610294 KN
4. Horizontal force to joint c Fjc = 22.683824 KN
5. Shear at Tower Base Fja = -5.444118 KN
Checking moment Mo = 771.25 KNm ok
1. Displacement at joint c
Ac1 = 490.874 mm2
Δh1 = 149.425 m
2. Displacement at joint b
Ac2 = 490.874 mm2
Δh2 = 21.385 m
MATERIAL
1. Frame types
2. Cable types
3. Strength 275 N/mm2
4. Modulus Elasticity 205 N/mm2
DIMENSION
1. Tower Height Ht = 25 m
2. Cable height h1 = 15 m
h2 = 10 m
3. Cable leg distance Ll = 5 m
4. Cable Length Lc1 = 25.495098 m
Fx1 Fx2 Lc2 = 15.811388 m
LOADING
###
1. Lateral Load Fx = 30.85 KN
90 90 2. Overturning moment Mo = 771.25 KNm
### 3. Horizontal force to joint b Fjb = 13.610294 KN
4. Horizontal force to joint c Fjc = 22.683824 KN
5. Shear at Tower Base Fja = -5.444118 KN
Checking moment Mo = 771.25 KNm ok
Fx3 Fx4
Fx1 TENSILE FORCE TO CABLE
Case 1 Case 2
1. Horizontal force to cable 1 Fhc = 16.039885 22.68382
2. Horizontal force to cable 2 Fhb = 9.6239313 13.61029
1. Displacement at joint c
Ac1 = 490.874 mm2
Δh1 = 149.425 m
2. Displacement at joint b
Ac2 = 490.874 mm2
Δh2 = 21.385 m