You are on page 1of 23

Project: VVVF MEGA 220V DOOR OPER.

SIMPLEX DOWN
150 mm 230 mm

Order: SV14648/14
+ - + - + - + -
Customer: PROFESSIONAL ELEVATOR & ESC.
85
0

60
55

0
65

-B2 -B3 -B4

220
-BL13

Designer: NASTRO M.
0

0
13

400
0

0
280 mm

12

18
24

12v 12v 12v


0
ELCA

12v

-RF
Date: 28/07/2014
+ - + - + - + -

-B1 -B5 -B6 -B7


F4 F6
Application Volts: 400V
-nUPSM -RM -RS

Auxiliary Volts: 48V


12v 12v 12v 12v
-

-BMEO2

12v

RSC -F1-F2-F3 -VA Application Frequency: 50HZ


-F10
-F11
-F12
-F13
-F5
-F7
-F8
-F9
+

A1 A2
115 mm

A3
-

-BMEO1

Nominal Current: 12A


12v

RSC
+

13 14

12

Power: 5,5KW
FUJI
-AL96 MEGA
IP Protection: IP44
120 mm

MoviLift s.r.l.
AL96
- - + +
Castellammare di Stabia (NA)
MoviLift
DISP900 rev1.0

via Napoli, 348 - 80053


265 mm

commerciale: 08119818392 - 0818707923


CABDR12 assistenza tecnica: 3931484017 - 3929809739
120 mm

AS

AD

RMN
230 mm fax: 08119308204
CABDR-12 RCI

RPT

RMN2
MADE IN ITALY direzione@movilift.com
RU

102 mm
1.2

-R220
-RCB

-K380 -K96
-RA

-RFR -TL -TL1


-RT
115 mm

102 mm
110 mm

1.A AS PROJECT 05/07/2013 NASTRO M. MONTELLA S. PIETRODANGELO F.

2.A AS BUILD 28/07/2014 NASTRO M. DE MARTINO A. PIETRODANGELO F.

160 mm
Rev. Changes Date Prepared Verified Approved

It isn't allowed give this document to third parties and it is not allowed use contents or show it to third parties without our explicit authorization. Each violation imply compensation.
PANEL 1000X600 All rights are reserved
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

INVERTER CONTROL INTERFACE nUPSM

CABDR12 EMERGENCY DEVICE FOR RAPID PROGRAMMING


HYSRAULIC AND ELECTRIC ELEVATOR

Button test
Battery output
AS
UP DIRECTION
4P 4P W V B- U B- B+ B+ Phase failure relay
During Emergency *
4th pole battery output inverter output battery 12/24V

AD NA
DOWN DIRECTION RS RD IF ICV
Phase failure relay NC
C
RMN
CABIN INSPECTION
CABDR-12
nUPSM
NA
RCI Phase failure relay NC MAN
HIGH SPEED (ON)
C
MoviLift N
RPT Automazione per ascensori
MANOEUVRE VOLTAGE
T1
Grid to controller output SPEEDY DATA UP DOWN
S1 PROG
RMN2
R1
INSPECTION FROM CONTROLLER

RU T
STOP Gris input 220/380V
S
R

NOTE
DISPLAY MENU Battery state Grid state During Emergency Description
0 = LIFT STOPPED ON ON OFF Discharged Battery TO CAN ENTER IN PROGRAMMING MODE, MOVE ON 'PROG' THE SWITCH
1 = UP DIRECTION OFF OFF OFF 4th pole deactivated ON DISPLAY AND WAIT BUSY LIGHT TURN ON. MOVE WITH 'UP' O 'DOWN'
2 = DOWN DIRECTION OFF ON OFF Normal Working
4 = LOW SPEED IN UP DIRECTION INTO INDEX AND PRESS 'DATA' TO CAN SEE PARAMETER VALUE; TO CAN
OFF OFF ON During Emergency
5 = LOW SPEED IN DOWN DIRECTION WARNING: COntrolles has Emergency device that allows to the elevator tocome on floor automatically
CHANGE IT KEEP DOWN 'DATA' AND USE 'UP' OR 'DOWN' TO CHENGE VALUE.
6 = INSPECTION By the supplying of power to the controller. Emergency cycle duration is 180sec; during it cabin move into TO CAN MOVE CABIN WITH DIRECT MANOUEVRE, MOVE ON 'MAN' THE SWITCH
lower floor (for hydraulic elevator) or into nearer floor (electric elevator) and it open doors. ON DISPLAY, THEN WITH 'SPEEDY' 'UP' OR 'DOWN' MOVE CABIN.
DURING INSPECTION FROM CABIN - LED RMN AND RMN2 ARE ON
Then elevator state stay in "BUSY". nUPSM start to work in absence of power closing '3PL' and '4PL'
DURING INSPECTION FROM CONTROLLER - LED RMN2 IS ON Emergency cycle work also when cabin is stopped to floor with opened or closed doors.

ISOLATION TEST INSTRUCTIONS: PROGRAMMABLE PARAMETER TABLE


- MOVE THE CABIN BETWEEN TWO FLOOR WITH CLOSED DOORS;
- MOVE TO OFF THE FEM AND CABIN LIGHT SWITCH;
PARAM. VALORI DESCRIZIONE
- REMOVE CONNECTIONS FROM ELECTRONIC BOARDS INTO
CONTROLLERS;
3 0 INDIPENDENT SERVICE ACTIVATION
- REMOVE POWER SUPPLY WIRES FROM BATTERIES; 13 4 SIMPLEX MANOEUVRE ACTIVATION OPTIMAL CONDITION LED ON SV
- REMOVE GROUND FLOOR WIRE (BLACK COLOR) FROM TERMINAL BOX (PE) 16 2-45 sec WAITING OPENED DOORS BEFORE PARKING
AT GROUND FLOOR WITH BUSY TURN OFF
POWER ON PAR. VAL. DESCRIPTION
WARNING: 17 2-45 sec MAX TIME FOR OPENING
CS ON 16 12 RECLOSING TIME
DON'T EXECUTE THE MEGGER TEST ON POWER CLAMPS OF INVERTER. *
ALT ON 24 30 BUSY TIME
DON'T EXECUTE THE MEGGER TEST ON COMMAND CIRCUITS OF INVERTER. 18 2-45 sec MAX TIME FOR CLOSING
EXC ON

CM1 ON
19 2-99 dec DELAY OPENED DOOR AFTER STOP ON FLOOR ON
tsd
EXECUTE THIS TEST ONLY INACCORDING TO THE NEXT TABLE: ON
cpp
21 10-99 sec DELAY MANOEUVRE * SERIAL
apg ON
DISPLAY DESCRIPTION
F.E.M. OUT FEM
CAR DOOR
LIGHT ALARM SIGNALS
SAFETY
VALVE BRAKE
22 10-99 sec MAX TRAVEL TIME (SET TIME FOR 1 LANDING)
OPERATOR SERIES 1100 CABIN OUT OF FLOOR
1111 CABIN AT INTERMEDIATE FLOOR
RST U V W MP MP MP L1 L2 L3 A1 A2 A3 10 11 CL FC ---6 EVL-EVD FR0-FR 24 10-90 dec BUSY TIME
0111 CABIN AT UPPER FLOOR
26 0-99 dec DELAY STOP
1011 CABIN AT LOWER FLOOR
GROUND
27 1-99 x 10 sec STATION FLOOR TIME * IF STANDING BEHIND 0000 ERROR SENSOR NOT DETECT
RST 30 0-99 sec MAX LEVELING TIME CLOSED DOORS

6
32 n° fermate NUMBERS OF STOPS
62 +32 OVERLOAD NC CONTACT
L1 L2 L3
63 0 MOVEBLE FLOOR ACTIVATION

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 2
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: LAYOUT
2.A 28/07/2014 NASTRO M. AS BUILD 1 3
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

INSPECTION ON CAR
EMERGENCY BATTERY ASSEMBLY

GND 2 3

INSPECTION

CONSENT
NORMAL
PSM UP

+90 +60

2B
STOP
PDM DOWN

+ - + - + - + -
2A

B1 B2 B3 B4

PHASE FAILURE
DETECTION RELAY
0V

L1 L2 L3

LED

OK WHEN IT IS FIXED TURN ON


RIGHT SEQUENCT R- S- T
+ - + - + - RSC

B5 B6 B7
11 12 14

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 3
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: BATTERY
2.A 28/07/2014 NASTRO M. AS BUILD 2 4
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

MOTOR GEAR
3PL 4PL
11.1 11.1
-K380
POWER SUPPLY

7 8 TMS
6.18 8.1
R. 1 2 1 2 BRAKE TMS
R 6.18 8.1
RESISTANCE
S. 4 3 4
THERMISTORS
3 S 6.18 -TL
T. 5 6
7.7 -TL1 U
5 6 T
1 2 L FR
MAIN FEM 380V 7.9 U 6.1
7.7 V

5
FR0
-F1-F2-F3 5 6 1 2
V
N
6.1
7.9 W
6A 5 6

6
W

SHIELDED
CABLE
PE
-RSC

DB

P+
L3

L2

L1
L1

W
U

V
10.3
5.20
L2 PE

7.3
-INVERTER

C2QM20

YELLOW
L3 SV
5.2

AP B-I1 BOX-I1

12
OPEN

OPERATOR DOOR 220V


GREY
R

T -nUPSM CP B-I2 BOX-I2

13
-nUPSM CLOSE
4.7 4.7 4.7
8.12

11.9
5.2
4.6
4.6
4.7
R1

GREEN
S1

T1

CRP B-COM BOX-COM

11
COM

WHITE
A-MP. BOX-MP
U

14
L

BROWN
A-MP BOX-MP.

15
N
-F7

OPERATOR DOOR
CABLE
C1QM20
3,15A
FOR DETAILS SEE
-TR SHEET 'OPERATOR'
0 400 0 18 0 220

BUS INV
10.1
0 65 0 12 0 56 0 72 BUS INV
10.1
-F10
3,15A
R 72
10.5
R 0
10.5
RM 56
5.1
RM 0
5.1
RS 12
5.1
RS 0
5.1
RF 65
6.1
RF 0
6.1
PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN
CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 4
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: POWER - OPERATOR
2.A 28/07/2014 NASTRO M. AS BUILD 3 5
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
6.24
-RM
VA
7.1
6.1
SV EXC
8.1
RM_0
-F4 30C 30A SV ALT
4.24 -VA 8.1
4A -CAB-DR12 RMN -INVERTER

9.1

4.9
-RSC
4.4 +
1A
SV CS
8.1

ONLY SEMIAUTOMATIC
RM_56
11 14 ~ ~
4.24 -
-nUPSM RPT

O-3C

O-3D

G-5A
4.7 -RM

B-4

B-5
3A

3B
I-FC1

M-1C
M-1B

C-1D

C-2A

C-2B
L-1A
I-FC

C-2

C-3
L-1
C NA -CAB-DR12
NC 9.1
BLUE

BROWN
BLUE BROWN

BROWN

BROWN
CABLE

BLUE
CABLE 6

BLUE

BLUE
PE 7.1
LANDING LOCKING
RS 12
CABLE CONTACT

LOWER GOVERNOR
CABLE
4.24 CABLE DOOR

0M
CL

G-6
LIMIT STOP IN PIT

LANDING DOOR
+
-F6

HIGH GOVERNOR SWITCH

LOCKING CONTACT
RS 0 ~ ~ SWITCH
4.24

STOP IN PIT
- -SV
3,15A

A1
GND
-RS
-RCB

LOWER GOVERNOR SWITCH


LIMIT SWITCH
BROWN

A2
48VCC CABLE
LOCKING
-RS
8.1 CONTACT
C-GND

D-GND

S-GND
C-CL
S-CL

PE

9 10 11 12 13 14 15
C1QM20 C2QM20

BOX-1D

BOX-2A

BOX-2B
BOX-2

BOX-3
6 5
C1QM20

BOX-4

BOX-5
BOX-GND.
BOX-CL

CONSENT
PINK BLUE
CABLE
N0M
OPERATOR DOOR
CIELING BOX

CONTACT OPERATOR DOOR


BLUE BROWN
BOX-84

CABLE
SAFETY GEAR

STOP
INSPECTION
SAFETY GEAR

N0M

OPERATOR DOOR

OPERATOR DOOR
NC

CABLE

CABLE
BOX-83

MAINTENANCE

BLACK
CAR

RED
BOX-93 BOX-92 85
SERADP03
RE-OPEN CONTACT
LIGHT RAYS
GND
15.1
GND
16.1

CL
15.1
PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN
CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 5
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: SIGNALS - MANOEUVRE
2.A 28/07/2014 NASTRO M. AS BUILD 4 6
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

BRAKE CIRCUIT/EMERGENCY
+60 BATT
10.1
FR0
-K96 10.1

6
6.16

5
-CAB-DR12

9.1
3
-TL
7.7

4
RF 0
-F5
4.24
4A

NA2

NA1
C2

C1
3
-K380 -RFR -TL1
6.18 7.5 +
7.9
RF 65 53 54 1 2 ~ ~

4
4.24 -

-RF

21

21
-K380 -K96
FILTER 6.18 6.16

22

22
PE

FR0 FR

FR0
4.24

A1

A1
FR -K96 -K380
4.24

A2

A2
48VCC
48VCC

VA -RM
5.23 5.24

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 6
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: BRAKE
2.A 28/07/2014 NASTRO M. AS BUILD 5 7
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

OUTPUT SV DEX
15.1
CKEX
15.1
-CAB-DR12 BAT SV
11.0

9.1

12V

A1
-RA

S-CKEX
S-DEX
X4-AD
X4-AS
RMN2

RCI

A2
T
12VCC

CKEX
OCC

DEX
CPF

BAT
VIM
TG
TD
TS
MAINBOARD
SV

-RT
6
9.11
5.24
11 14
12
-INVERTER
4.9

Y5A Y5C
A1

A1

A1

-RFR -TL -TL1


A2

A2

A2

48VCC 48VCC 48VCC


-RM
5.24

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 7
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: OUTPUT SV
2.A 28/07/2014 NASTRO M. AS BUILD 6 8
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

-RS
INPUT SV
5.8

C1
21

61
-nUPSM

TMS.
-TL 4.7 -K380

NC1
NA1
7.7 6.18

22

62
TMS
4.24

TMS

X1-GND
4.24 -CAB-DR12

RU

9.1
21
TMS
-TL1

APG

MN1
CPP
7.9

22
GND.

MAN
APG
CPP

PAP
TSD

EM
TM

TO
SV EXC EXC
5.24

CS
SV
SV CS
MAINBOARD
5.24

CT

VIM.
DIN

INT
ALT

KI
5.24 SV ALT

D-VIM
D-CK

D-DA

D-SI
3 4 2 1
C1QM20

SI
16.1
VIM
16.1
DA
16.1
CK
16.1

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 8
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: INPUT SV
2.A 28/07/2014 NASTRO M. AS BUILD 7 9
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

ENCODER OPTION
INVERTER FUJI MEGA (SIDE PANEL)

P0 RED +

CM BLACK -

YA WHITE A+

*YA RED 0,22 A-


PE L1 L2 L3 DT+ DT- CK+ CK- PA+ PA - PB+ PB - CM PO R0 T0 FPA FPB P0 FM2 V2 U V W
ENCODER YB GREY B+

INVERTER FUJI NC
*YB YELLOW B-

ENCODER
CABLE
PLC X6 FWD REV X2 X1 X3 EN1 EN2 X5 CM CMY- Y1+ Y5A Y5C 30B 30A 30C

SEE PAG.7 SEE PAG.5

53
-TL
7.7

54
'LIKA' ENCODER CONNECTIONS
53
-TL1
7.9
54

INVERTER COLOURS KEY

RED BLACK YELLOW BLUE GREEN ORANGE


PLC - COMMON INVERTER SIGNALS - GREEN CABLE
11

ENCODER
FWD - INVERTER UP DIRECTION START - PINK OR ORANGE
'LIKA'
-RCB REV - INVERTER DOWN DIRECTION START YELLOW
12
14

73

5.23
X2 - LOW SPEED RAMP - GRAY
-K96
X2-AD
X2-AS

MN

6.16
B

X1 - HIGH SPEED RAMP - WHITE


74

X3 - INSPECTION SPEED - BROWN


+ = POSITIV
A2

A+

B+
X5 - BRAKE CONTROL - BLUE

A-

B-
+

-
CIN

- = NEGATIV
5.13

8.10

6.15

-RT
7.9

5.6

-CAB-DR12 Y5C - COMMON BRAKE RELEAY - PINK 0,75 (2°)


A+ = CHANNEL 'A+'
A1

Y5A -BRAKE RELEAY - RED 0,50 (1°)


24VCC
A- = CHANNEL 'A-'
Y1 - TL ADMINISTRATION RELAY - BLACK 0,50 (1°)

B+ = CHANNEL 'B+'
30A - FAULT INVERTER RELAY - WHITE0,75 (2°)

B- = CHANNEL 'B-'
30C - FAULT INVERTER RELAY - GREEN 0,75 (2°)

EN - ENABLE - RED 0,22 CLAMPS PANEL

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 9
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: INVERTER I/O
2.A 28/07/2014 NASTRO M. AS BUILD 8 10
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

EMERGENCY SCHEME

4.9 -INVERTER

.L1

.L2

R0

T0
54

84
-K96 -K96
2

4
-K96 -K96 6.16 6.16
6.16 6.16

53

83
1

-F8

20A

-AL96

+95 -
~.
~

R 0 -F12
4.24
2A
R 72
4.24

96V -B1 -B2 -B3 -B4 -B5 -B6 -B7 0V


+60 BATT
6.23
-F11 4A
FR0
6.23
BUS INV
4.24
BUS INV
4.24

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 10
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: EMERGENCY
2.A 28/07/2014 NASTRO M. AS BUILD 9 11
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

BAT SV
-F9
7.24
2A
3P
4.1
4P
4.5 SONAR

12 14 INTERCOM 4PL 3PL


BROWN BLUE
PANEL
-BL13 CABLE
-RA ABB
12V/7AH
7.16 SONAR

N-SR+

N-SR-
11
A1

-R220

4P.
4P
RESET
ALARM
A2

BUTTON
220VCA -nUPSM

4.7
400W
PE
-F13 11

B-.
B+
1A 3 4 24 2 25 -R220
11.1
14 12

L1 L2 L3 L4

17 18 19 16
C1QM20 -BMEO2 -BMEO1
TELEPHONE
LINE

12V/7AH
H-PRA
H-CT1

H-CT2

12V/7AH

H-A1
LT LT.

H-LEM
H-A2

H-A3

H-A5
L1 L2 L3 L4

-FAN
6 7 8
C2QM20
1 2 3 5 4 9 10
C2QM20

LT
SOCKET 16.1
LT

A5
16.1
LO LF 16.1
CIELING BOX

LIGHT BUSY/FIXED
LEM
PRA
16.1
CT1
16.1
3
CT2
16.1
4 16.1
INTERCOM
BOX
25
A1
ABB 16.1
24 A2
16.1
ALARM ACTIVATION
A3
2 16.1

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 11
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: EMERGENCY
2.A 28/07/2014 NASTRO M. AS BUILD 10 12
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

CLAMPS PANEL

C2QM20

C1QM20

C1QM20
CIQM20

COM

GND

GND
VIM
MP.
MP

CK

DA
1D
CL

2A

2B

SI
I1

I2

3
A B C D
STOP/INTERCOM IN PIT

ONLY
SEMIAUTOMATIC
LOWER GOVERNOR
LOCKING CONTACT

INTERCOM IN PIT

LANDING DOOR
CABLE SONAR
LIMIT SWITCH

MAIN CABLE
FOR LOPS

C1QM20
C2QM20
CABLE

CABLE

CABLE

CABLE

CABLE

CKEX
GND

GND

TMS

TMS
LEM

PRA

DEX
SR+
CT1

CT2

FC1

FR0
3PL

4PL
SR-

LT.
FC

FR
1C

3C

3D

CL
5A

1A

1B

3A

3B
A1

A2

A3

A5

LT

L1

L2

L3

L4

W
R

U
S

V
T
6

G H I L M N O S
PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN
CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 12
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: CONTROLLER TERMINAL BOARD
2.A 28/07/2014 NASTRO M. AS BUILD 11 13
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

CABIN TERMINAL BOARD CONNECTIONS 1 2 3

LIGHT RAYS CONTACT

OVERLOAD CONTACT
RE-OPEN CONTACT
10->L15 10->L19 SMD 10->L23

ALIM. LIGHT RAYS


FM 9->I15 PDM 9->I19 IF 9->I23
8->L14 8->L18 SMS 8->L22
7->I14 PSM 7->I18 ICV 7->I22
6->L13 6->L17 SVC 6->L21
74 5->I13 PAP 5->I17 IRD 5->I21
4->L12 4->L16 14 4->L20
85B 3->I12 85A 3->I16 IRS 3->I20
2->GND 2->GND 2->GND

1->+12V 1->+12V 1->+12V

36 37 38 39 40 41 42 43
45 46 47 48 49 50 55 56 57 58 59 60 61 62 63 64 65 66 67 68

GND
I2

COM
92
93

I1
5
4

83

84

CL

GND

75

CL
GND
DA
CK
VIM
SI
3
2B
2A
2
1D
85A(SERADP03)

45 37 63 62 63 63 47 46

74(SERADP03)
48 SERCAR (CABIN CONNECTIONS)
50

BROWN GND
VIM
CK
GREEN DA
WHITE

YELLOW
(SNV200)
CABLE
R+ R- EXCON

VOICE SYNTHESIS
SNV 200
MP
MP

A1
A2
A3

LEM
CT1
CT2
PRA
LT
LT

SP
SP
A5
L1
L2
L3
L4

R+

R-
1 2 7 8 9 10 11 12 13 14 15 16 17 18
SP
16.1
SP
16.1

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 13
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: BOX TERMINAL BOARD
2.A 28/07/2014 NASTRO M. AS BUILD 12 14
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
2.A
1.A
0

REV.
1

DATE
28/07/2014
05/07/2013
2

NASTRO M.
NASTRO M.

SIGNATURE
3

68
1-SI 1-SI
2-VIM 2-VIM
D

3-CK 3-CK
4

4-DA 4-DA
5-GND 5-GND
6-CL 1° -20 CONDUCTOR CABLE 6-CL
BLACK CABLE
5

7- 7-

AS BUILD
8-

CHANGES
8-
C

AS PROJECT
9- 1D 9- 1D
6

10- 2 10- 2
11- 2A C1QM20 11- 2A

55
12- 2B 12- 2B
13- 3 13- 3
7

14- MP 14- MP

1--2
15- MP
A

15- MP
16-L4 16-L4
8

17- L1 17- L1
18- L2 18- L2
19- L3 19- L3
9

GROUND GROUND
10

7
1-A1 1-A1
2-A2 2-A2
3-A3 3-A3
11

4-A5 4-A5
H

5- LEM 5- LEM
6- CT1 6- CT1
12

BLACK CABLE

7- CT2
2° -20 CONDUCTOR CABLE 7- CT2
8- PRA 8- PRA
9- LT 9- LT
13

10-LT 10-LT
11- COM C2QM20 11- COM

16 43
12-I1 12-I1
13-I2 13-I2
B
14

14-4 14-4

36
15-5 15-5
16- 16-
15

17 17
18- 18-

TITLE:
19- 19-
CLIENT:
ORDER:
16

GROUND GROUND
PROJECT:

DIS.: NASTRO M.
17

CABLES
SV14648/14
18
19
20

PROFESSIONAL ELEVATOR & ESC.


21

DATE: 28/07/2014
VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN
22

OF
23

13
SHEET

37
14

15
24
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

MAIN CABLE FOR LOP


BROWN
CKEX
7.24
BLACK
DEX
7.24
YELLOW/GREEN
GND
5.24
GRAY
CL
5.24
MAIN CABLE
FOR LOP

CEX

CEX

CEX

CEX

CEX
KE

KE

KE

KE

KE
CL

CL

CL

CL

CL
20

20

20

20

20
LCD 601 LCD 601 LCD 601 LCD 601 LCD 601

SW2 SW1 SW2 SW1 SW2 SW1 SW2 SW1

CB0061
CALL DOWN

CALL DOWN

CALL DOWN

CALL DOWN

CALL DOWN
CALL UP

CALL UP

CALL UP
RESERVED

RESERVED

RESERVED

RESERVED

RESERVED

RESERVED

RESERVED

RESERVED
FLOOR 0 FLOOR 1 FLOOR 2...3 FLOOR 4 FLOOR 5
PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN
CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 15
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: LOPS CONNECTIONS
2.A 28/07/2014 NASTRO M. AS BUILD 14 16
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

COP
CIELING BOX

LT BOX-LT. BLACK
11.24
LT BOX-LT PURPLE
11.24

LEM BOX-LEM GREY


11.24
PRA BOX-PRA RED LT LT SAR LE- C_AR
11.24 PRA C_AA
A3 BOX-A3 GREEN
11.24 COM AA LEM
CT1 BOX-CT1. PINK
COMBIVOX
11.24 1 AR
LE+
CT2 BOX-CT2. BLUE
11.24 2
SAA +12
A5
BOX-A5 YELLOW
11.24
A1 BOX-.A1 WHITE
11.24

A2 BOX-A2 BROWN
11.24
SERADP03-PDM ALARM BUTTON

1° FROR
SERADP03-PSM
SERADP03
AMP
MAINTENANCE

GONG
DOWN BUTTON

UP BUTTON

BISTABLE SERADP03-IRS IN SERCAR AMP


BISTABLE SERADP03-IRD RED

N,O AMP JS7


SERADP03-ICV

N,O SERADP03-IF
JS7 JS7
KEY

OVERLOAD F4...F5
74 SERCAR
AMP
F2 F3
LCD
EXCON

OPTIONAL .GND
CABLE

SI BOX-SI
8.24
INDIPENDENT AMP
YELLOW GREEN BROWN

GND
SERVICE KEY BROWN/YELLOW
5.24
JST
CK BOX-CK WHITE/GREEN
JS7 JS7
EXCON

8.24
DA BOX-DA BROWN/GREEN
8.24 OPEN DOOR
WHITE

VIM BOX-VIM BLUE/RED


8.24
JST F0 F1
AMP
BROWN
SP BOX-SP
13.23 CLOSE DOOR
BLUE
SP BOX-SP. 2X1
13.23

SPEAKER FOR
VOICE SYNTHESIS
PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN
CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 16
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: COP
2.A 28/07/2014 NASTRO M. AS BUILD 15 17
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

FERMATOR VVVF FLY 2SG HYDRAPLUS SELCOM PRISMA MICRO


DOOR OPERATOR DOOR OPERATOR DOOR OPERATOR DOOR OPERATOR
CLAMPS PANEL CLAMPS PANEL CLAMPS PANEL CLAMPS PANEL
BOARD BOARD BOARD BOARD
85 39 85 9 85 14 85 J2-9

GND 40 1 GND 15 GND J2-8


8

I1 I1 1 I1 I1 J1-4
12 J3 I1 J3-4
7 2 J1-3

I2 8 I2 I2 I2 J3-3
I2
6

COM 9 DOOR COM DOOR COM COM DOOR COM J3-5 DOOR
8
OPERATOR OPERATOR OPERATOR OPERATOR
11 MOTOR MOTOR MOTOR MOTOR
MP MP MP MP.
7 L 1 L

.MP 10 MP. .MP MP


5 N 2 N

DAPA/VEGA CMM SEMATIC


DOOR OPERATOR DOOR OPERATOR DOOR OPERATOR
CLAMPS PANEL CLAMPS PANEL CLAMPS PANEL
BOARD BOARD BOARD
85 15 85 K3A 85 1

GND 13 GND K3B 86 4

I1 I1 I1 43
AP40 IN2 5
44

I2 CH40 I2 IN1 I2 3

COM VF DOOR GND DOOR COM 15 DOOR


OPERATOR OPERATOR OPERATOR
MOTOR MOTOR MOTOR
MP MP MP
24/48 L F
TERMINAL BOX LEGEND:
MP. MP. .MP
24/48 N N 85 = LIGHT RAYS CONTACT/RE-OPEN CONTACT
COM0 I1 = OPENING DOOR SIGNAL
I2 = CLOSING DOOR SIGNAL
12/24
COM = COMMON SIGNALS
COM0
MP = ALIMENTATION DOOR OPERATOR BOARD

THE CLAMPS '85', 'COM', 'I1', I2' IN LIFTS WITH DOUBLE


GND
ENTRIES ARE INDICATED WITH SUFFIX 'A' AND 'B'

PROGETTO: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENTE: PROFESSIONAL ELEVATOR & ESC.
FOGLIO 17
COMMESSA: SV14648/14 DI 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITOLO: DOOR OPERATOR
2.A 28/07/2014 NASTRO M. AS BUILD 16 18
REV. DATA FIRMA MODIFICA DIS.: NASTRO M. DATA: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

MAGNETS DISPOSITION
TOP FLOOR

START DOWN STOP

DOOR ZONE
FLOOR 1

START UP STOP
FLOOR 3
110 ~ CM

** SEE MANUAL INVERTER

FLOOR 2

X X

ICV IF
GND-ICV GND-IF

FLOOR 1

WARNING:
ICV - IF sensors have been turn on when elevator is on floor

LOWER FLOOR

BISTABLE

N.A. N.A. B B

IRD IRS
ICV IF
GND-ICV GND-IF GND-IRD GND-IRS

(IS) (ID) (IRD) (IRS)


ICV = SELECTOR/STOP SENSOR IRD= DOWN LIMIT SENSOR B= BISTABLE
IRS= UP LIMIT SENSOR N.A.= MONOSTABLE N.A
IF = SELECTOR/STOP SENSOR
PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN
CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 18
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: MAGNETS AND SENSOR DISPOSITION
2.A 28/07/2014 NASTRO M. AS BUILD 17 19
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

SENSOR DISPOSITION INTO GUIDE RAILS SYMBOLS LEGEND

Simbolo Radice Funzione Simbolo Radice Funzione


GUIDE
SEZIONATORE AUTOMATICO DI POTENZA SENSORE INDUTTIVO QUADRATO
AUTOMATIC POWER DISCONNECTING SWITCH SQUARE INDUCTIVE SENSOR
QF SECTIONNEUR AUTOMATIQUE DE PUISSANCE
SECCIONADOR AUTOMATICO DE POTENCIA
SQ SENSEUR INDUCTIF CADRAT
SENSOR INDUCTIVO CUADRATO
AUTOMATISCHEN LEISTUNG TRENNSCHALTER QUADRATISCHER INDUKTIVSENSOR
INTERRUTTORE GENERALE AUT MAGNETICO INDUTTANZA
AUT MAIN GENERAL SWITCH INDUCTOR
MAGNETS QM INTERRUPTEUR GENERAL AUT MAGNETIQUE
INTERUPTOR GENERAL AUT MAGNETICO
L INDUCTANCE
INDUCTANCIA
STOP GENERALSCHALTER AUT MAGNETISCH INDUKTIVITAT
INTERRUTTORE AUTOMATICO DI POTENZA PULSANTE MANUALE NORMALMENTE APERTO
POWER SUPPLY SWITCH MANUAL PUSH BUTTON NORMALLY OPENED
QF INTERRUPTEURAUTOMATIQUE DE PUSSANCE
INTERUPTOR AUT. DE POTENCIA
S POUSSOIR MANUEL NORMALMENT OUVERT
BOTON MANUAL NORMALMIENTE ABIERTO
LEISTUGSSCHALTER AUTO HANDKNOPF NO
INTERRUTTORE AUT MAGNETICO DIFFERENZIALE PULSANTE MANUALE NORMALMENTE CHIUSO
AUT DIFFERENTIAL MAGNETIG SWITCH MANUAL PUSH BUTTON NORMALLY CLOSED
QM INTERRUPTEUR AUT MAGNETIQUE DIFFERENTIEL
S POUSSOIRE MANUEL NORMALMENT FERME
PLACE MAGNETS AS IN FIGURE INTERRUPTOR AUT MAGNETICO DIFFERENCIAL BOTON MANUAL NORMALMIENTE CIERRE
AUT DIFFERENTIALEN MAGNETISCHEN SCHALTER HANDKNOPF NC
IN PROXIMITY OF STOPS BOBINA CONTATTORE POTENZA PULSANTE EMERGENZA
POWER CONTACTOR REEL EMERGENCY PUSH BUTTON
KM BOBINE CONTACTEUR PUISSANCE
BOBINA CONTACTOR POTENCIA
SB POUSSOIR URGENCE
BOTON EMERGENCIA
LEISTUNGSKONTAKTOR ROLLE FESTER NOTKNOPF
RELE' AUSILIARIO SELETTORE A CHIAVE DUE POSIZIONI
AUX RELAY TWO POSITION SWITCH KEY
B

KA RELE AUX
SA SELECTEUR CLE DEUX POSITION
RELE AUXILIAR SELECTOR LLAVE DOS POSICION
NEBENRELAIS
S

SCHLÜSSELSCHALTUNG ZWEI STELLUNGEN


V

IR
IC
IF

ELETTROVALVOLA LAMPADA
SOLENOID VALVE LAMP
YV ELECTROVANNE
ELECTROVALVULA
HL LAMPE
LAMPARA
ELEKTROVENTIL LÄMPCHEN
CONTATTO AUSILIARIO NORMALMENTE CHIUSO SEGNALAZIONE QUADRO IN TENSIONE
AUX CONTACT NORMALLY CLOSED ELECTRIC PANEL VOLTAGE SIGNALING
BISTABLE MAGNETS K CONTACT AUX NORMALMENT FERME
HL SIGNALISATION TABLEAU ELECTRIQUE
CONTACTOS AUX NORMALMIENTE CIERRE SENALACION CUADRO EN TENSION
NEBENKONTAKT NC SPANNUNGSANZEIGE SCHALTFELD
CONTATTO AUSILIARIO NORMALMENTE APERTO MOTORE TRIFASE
MAGNETS SUPPORT AUX CONTACT NORMALLY OPENED THREE PHASE MOTOR
K CONTACT AUX NORMALMENT OUVERT
M MOTEUR TRIPHASE
CONTACTOS AUX NORMALMIENTE ABIERTO MOTOR TRIFASE
NEBENKONTAKT NO DREIPHASIGER MOTOR
CONTATTI CONTATTORE DI POTENZA MOTORE CORRENTE CONTINUA
POWER CONTACT DC MOTOR

GUIDE
LAST FLOOR KM CONTACT CONTACTEUR PUISSANCE
CONTACTOR POTENCIA
M MOTEUR COURANT CONTINU
GLEICHSTROM MOTOR
ICV LEISTUNGSKONTAKT MOTOR CORRIENTE CONTINUA
CONTATTI AUSILIARI IN SCAMBIO RELE' PRESA SERVIZIO
RELAY EXCHANGE AUX CONTACTS SOCKET SERVICE
K CONTACT AUX EN ECHANGE
XP PRISE SERVICE
CONTACS AUX EN CAMBIO TOMA DE SERVICIO
NEBENKONTAKTE RELAIS BETRIEBSDOSE
PRESSOSTATO MORSETTO
PRESSURE GAUGE TERMINAL BLOCK

PLACE MAGNETS AS IN FIGURE


SP PRESSOSTAT
X ETAU
PRESOSTATO ABRAZADERA
DRUCKWÜCHTER KLEMME
FINECORSA NC MORSETTO CONNETTORE
NO LIMIT SWITCH NC CONNECTOR CONTACT
SQ FIN DE COUSE NF
XC ETAU
TOPA DE RECORRIDA NC ABRAZADERA CONECTOR
LOWER FLOOR ENDAUSSCHALTER NC ANSCHLUSSKLEMME
B

B
S

D
V

IR
IC

IR
IF

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 19
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: SENSOR DISPOSITION
2.A 28/07/2014 NASTRO M. AS BUILD 18 20
REV. DATE SIGNATURE CHANGES DIS.: NASTRO M. DATE: 28/07/2014
MATERIAL LIST
Sigle Description Code Builder Location Position
PANEL 100X60X30 MOVILIFT QP 1.
AL96 POWER SUPPLY 96V AL96 MOVILIFT QP 10.7
B1 BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 10.4
B2 BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 10.5
B3 BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 10.6
B4 BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 10.8
B5 BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 10.9
B6 BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 10.10
B7 BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 10.11
BMEO BATTERY 12V BATTERIA 12V 7AH MOVILIFT QP 11.10
CAB-DR12 INVERTER CONTROL INTERFACE CABDR12 MOVILIFT QP 9.1
F10 FUSE BUS INVERTER 3,15A 011565725 ABB QP 4.14
F11 FUSE BATTERY EMERGENCY4A 011565725 ABB QP 10.4
F1-F2-F3 MAIN FUSE 380V 6A 263879 MOELLER QP 4.6
F4 MANOEUVRE FUSE 4A 011565725 ABB QP 5.2
F5 BRAKE FUSE 4A 011565725 ABB QP 6.6
F6 SIGNAL FUSE 3,15A 011565725 ABB QP 5.2
F7 OPERATOR FUSE 3,15A 011565725 ABB QP 4.14
F8 FUSE BATTERY EMERGENCY20A 011565725 ABB QP 10.4
F9 FUSE EMERGENCY2A 011565725 ABB QP 11.13
INVERTER INVERTER MEGA FRN5.5G1E-4E FUJI QP 4.9
K380 380V CONTACTOR WB2DB SIEI QP 6.19
K380 380V CONTACTOR WH1FF SIEI QP 6.19
K96 CONTACTOR CONTROL BATTERY WB2DB SIEI QP 6.16
K96 CONTACTOR CONTROL BATTERY WH1FC SIEI QP 6.16
K96 CONTACTOR CONTROL BATTERY WH1LA SIEI QP 6.16
nUPSM ROPE EMERGENCY DEVICE nUPSM MOVILIFT QP 4.7
R220 EMERGENCY LIGHT RELAY G2R2SN220 OMRON QP 11.1
RA BUSY RELAY 485270240050 FINDER QP 7.16
RCB LOCKING CONTACT RELAY G2R2SN OMRON QP 5.23
RF BRAKE RECTIFIER RADDRIZZATORE MOVILIFT QP 6.7
RFR BRAKE CONTACTOR WB2DB SIEI QP 7.5
RM MANOEUVRE RECTIFIER PON MOVILIFT QP 5.4
RS SIGNAL RECTIFIER PON MOVILIFT QP 5.4
RSC PHASE FAILURE DETECTION RELAY NA10 MOVILIFT QP 4.4
RT RELAY FOR LINE CONTACTOR 485270240050 FINDER QP 9.11
SV PRINCIPAL MOTHERBOARD MV900 MOVILIFT QP 5.5
T380 TIMER FOR K380V H3DS-AL0 OMRON QP 6.22
TL LINE CONTACTOR WB2DB SIEI QP 7.7
TL LINE CONTACTOR WH1FM SIEI QP 7.7

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 20
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: MATERIAL LIST
2.A 28/07/2014 NASTRO M. AS BUILD 19 21
REV. DATE SIGNATURE CHANGE DIS.: NASTRO M. DATA: 28/07/2014
MATERIAL LIST
Sigle Description Code Builder Location Position
TL1 LINE CONTACTOR WB2DB SIEI QP 7.9
TL1 LINE CONTACTOR WH1FM SIEI QP 7.9
TR MAIN TRANSFORMER TM162-20965 ELCA QP 4.5
TR2 TRANSFORMER SECONDARY TM110-08714 ELCA QP 10.7
VA AUTOMATIC VALVE 1A 243141 MOELLER QP 5.5
F12 FUSE BUS INVERTER 2A 011565725 ABB QP 10.6
F13 FUSE FAN ON CABIN 1A 011565725 ABB QP 11.3

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 21
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: MATERIAL LIST
2.A 28/07/2014 NASTRO M. AS BUILD 20 22
REV. DATE SIGNATURE CHANGE DIS.: NASTRO M. DATA: 28/07/2014
CLAMPS LIST
Sigle Description Code Builder Location Position
A-MP OPERATOR BOARD SUPPLY 011596411 ABB 4.16
B-4 CONTACT DOOR 011596411 ABB 5.19
B-5 CONTACT DOOR 011596411 ABB 5.20
B-COM COMMON CONTROL OPERATOR 011596411 ABB 4.16
B-I1 OPEN CONTROL OPERATOR 011596411 ABB 4.16
B-I2 CLOSE CONTROL OPERATOR 011596411 ABB 4.16
C-1D SAFETY GEAR 011596411 ABB 5.12
C-2 INSPECTION 011596411 ABB 5.13
C-2A INSPECTION 011596411 ABB 5.15
C-2B INSPECTION 011596411 ABB 5.15
C-3 STOP ISPECTION 011596411 ABB 5.16
C-CKEX SERIAL COMMUNICATION DISPLAY 011596411 ABB 7.18
C-CL COMMON LIGHT 011596411 ABB 5.3
C-DEX SERIAL COMMUNICATION DISPLAY 011596411 ABB 7.17
C-GND COMMON SENSORS 011596411 ABB 5.4
D-CK SERIAL COMMUNICATION CABIN 011596411 ABB 8.12
D-DA SERIAL COMMUNICATION CABIN 011596411 ABB 8.13
D-GND COMMON SENSORS 011596411 ABB 5.6
D-SI INDIPENDENT SERVICE KEY 011596411 ABB 8.15
D-VIM SERIAL COMMUNICATION CABIN 011596411 ABB 8.14
G-5A LOCKING CONTACT 011596411 ABB 5.21
G-6 LOCKING CONTACT 011596411 ABB 5.23
H-A1 POSITIV BATTERY 12V 011596411 ABB 11.16
H-A2 ALARM BUTTON IN CABIN 011596411 ABB 11.19
H-A3 NEGATIV BATTERY 12V 011596411 ABB 11.19
H-CT1 INTERCOM 011596411 ABB 11.6
H-CT2 INTERCOM 011596411 ABB 11.7
H-LEM EMEGENCY LIGHT 011596411 ABB 11.20
H-PRA RESET ALARM BUTTON 011596411 ABB 11.7
I-FC LIMIT SWITCH 011596411 ABB 5.8
I-FC1 LIMIT SWITCH 011596411 ABB 5.9
L-1 STOP IN PIT 011596411 ABB 5.10
L-1A STOP IN PIT 011596411 ABB 5.10
M-1B LOWER GOVERNOR 011596411 ABB 5.11
M-1C LOWER GOVERNOR 011596411 ABB 5.12
N-SR+ POSITIV SONAR 011596411 ABB 11.19
O-3C LANDING DOOR 011596411 ABB 5.18
O-3D LANDING DOOR 011596411 ABB 5.18
Q1-3A HIGH GOVERNOR 0115206.22 ABB 5.16
Q1-3B HIGH GOVERNOR 0115206.22 ABB 5.17

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 22
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: CLAMPS LIST
2.A 28/07/2014 NASTRO M. AS BUILD 21 23
REV. DATE SIGNATURE CHANGE DIS.: NASTRO M. DATA: 28/07/2014
CLAMPS LIST
Sigle Description Code Builder Location Position
Q1-3PL 3°MAGNETOTERMIC POLE 0115206.22 ABB 11.11
Q1-4PL 4°MAGNETOTERMIC POLE 0115206.22 ABB 11.10
Q1-FR BRAKE 0115206.22 ABB 6.10
Q1-FR0 BRAKE 0115206.22 ABB 6.7
Q1-L1 LIGHT 220V 0115206.22 ABB 11.1
Q1-L2 LIGHT 220V 0115206.22 ABB 11.2
Q1-L3 LIGHT BUSY 220V 0115206.22 ABB 11.2
Q1-R MAIN FEM 400V 0115206.22 ABB 4.5
Q1-S MAIN FEM 400V 0115206.22 ABB 4.5
Q1-T MAIN FEM 400V 0115206.22 ABB 4.5
Q1-U 400V - ALIMENTATION PUMP 0115206.22 ABB 4.18
Q1-V 400V - ALIMENTATION PUMP 0115206.22 ABB 4.18
Q1-W 400V - ALIMENTATION PUMP 0115206.22 ABB 4.18
-SR- NEGATIV SONAR 011596411 ABB 11.19

PROJECT: VVVF MEGA 220V DOOR OPER. SIMPLEX DOWN


CLIENT: PROFESSIONAL ELEVATOR & ESC.
SHEET 23
ORDER: SV14648/14 OF 37
1.A 05/07/2013 NASTRO M. AS PROJECT TITLE: CLAMPS LIST
2.A 28/07/2014 NASTRO M. AS BUILD 22
REV. DATE SIGNATURE CHANGE DIS.: NASTRO M. DATA: 28/07/2014