Pull/Push DC Solenoids for RPS-00092B

Revised 11-03

Diesel Engines Catalog Section 40


(00-02-0107)

RP Series
■ One Solenoid For Pull/Push Operation
■ No Internal Switches
■ Reduce Coil Burnout
■ Boost Reliability
■ Reduce Adjustments
RP2309B & RP2310B
■ High Force–Small Size
■ Can Be Used With Most Engines
Start Systems
■ SD85 Solenoid Drive Time Delay
Available To Greatly Reduce Possibility
Of Coil Burnout And Facilitate Low
RP2307B & RP2308B Current Piloted Operation.

Description They will operate at any stroke less than with each operation. If the plunger does
Murphy push/pull DC Solenoids maximum; refer to the chart shown on not seat in that time, it is highly
provide single unit versatility for engine page 2. unlikely it will seat. The hold coil is
applications, such as shutdown. Models RP2309B and RP2310B can energized as long as the signal to the
pull 14 pounds (62 N) with a one-and-a- SD85 is active. This insures long life of
A choice of two models and two the RP solenoid.
voltages is available. All models come half inch (38 mm) stroke. They hold up
complete with return spring and rubber to 34 pounds (151 N) at full voltage,
continuous duty. See the chart on page 2 Warranty
seal boot. See the next page for A limited warranty on materials and workmanship
specifications and options. for holding force at any stroke less than
is given with this FW Murphy product. A copy of
maximum. the warranty may be viewed or printed by going
Basic Models to www.fwmurphy.com/support/warranty.htm
Models RP2307B and RP2308B give a SD85 Solenoid Drive
full one inch (25 mm) stroke at 11 Time Delay
pounds (49 N) and hold up to 23 pounds Using the SD85 ensures the energize
(102 N) at full voltage, continuous duty. coil is only powered for 1-2 seconds

MODEL & PART NUMBERS: DC SOLENOIDS & ACCESSORIES SHIPPING WEIGHT


Model No. Description ozs (kg)
RP2307B 12 VDC, 1 in. (25 mm) stroke, 11 lbf (49 N) pull, 23 lbf (102 N) hold 24 ozs (0.7 kg)
RP2308B 24 VDC, 1 in. (25 mm) stroke, 11 lbf (49 N) pull, 23 lbf (102 N) hold 24 ozs (0.7 kg)
RP2309B 12 VDC, 1-1/2 in. (38 mm) stroke, 14 lbf (62 N) pull, 34 lbf (151 N) hold 48 ozs (1.4 kg)
RP2310B 24VDC, 1-1/2 in. (38 mm) stroke, 14 lbf (62 N) pull, 34 lbf (151 N) hold 48 ozs (1.4 kg)
65-01-0108 Clevis yoke assembly 1 ozs (.03 kg)
65-01-0110 Clevis yoke chain assembly 2 ozs (.04 kg)
40-05-0315 Threaded rod (1-1/2 in.) .05 ozs (.001 kg)
00-00-2457 RPS in-line ball joint .05 ozs (.001 kg)
00-00-2458 RPS 90° ball joint 1 ozs (.03 kg)

RPS-00092B page 1 of 4
Watts Power/Cold Force in Pounds at 100% Voltage/Inches Stroke

Solenoid Maximum Power in Watts Force* in Pounds [Kilograms] at 100% Voltage**


Model Stroke Stroke in Inches (Millimeters)
Continuous
Number In. (mm) Seated Inrush Hold 1/8 (3) 1/4 (6) 1/2 (13) 3/4 (19) 1 (25) 1-1/4 (32) 1-1/2 (38)
25 [11.34] 22 [9.98] 21 [9.53] 17 [7.71] 14 [6.35] 10 [4.54] — —
RP2307B 1 (25) 18 624
<13> [5.90] <12> [5.44] <11> [4.99] <10> [4.54] <8> [3.63] <6> [2.72] — —
27 [12.25] 25 [11.34] 23 [10.43] 19 [8.62] 15 [6.80] 11 [4.99] — —
RP2308B 1 (25) 12 696
<15> [6.80] <14> [6.35] <13> [5.90] <12> [5.44] <9> [4.08] <7> [3.18] — —
32 [14.52] 30 [13.61] 27 [12.25] 22 [9.98] 18 [8.16] 13 [5.90] 8 [3.63] 6 [2.72]
RP2309B 1-1/2 (38) 18 1029
<19> [8.62] <18> [8.16] <16> [7.26] <14> [6.35] <11> [4.99] <9> [4.08] <6> [2.72] <4> [1.81]
35 [15.88] 34 [15.42] 31 [14.06] 26 [11.79] 22 [9.98] 17 [7.71] 12 [5.44] 7 [3.18]
RP2310B 1-1/2 (38) 12 960
<20> [9.07] <19> [8.62] <17> [7.71] <15> [6.80] <12> [5.44] <9> [4.08] <7> [3.18] <4> [1.81]

*Forces shown are without return spring. Forces shown < > are with return spring. Forces shown in [ ] are in kilograms.
**To determine the operating current, divide the power (watts) indicated in the above table by the applied voltage.
Solenoids will operate at any stroke less than maximum.

Solenoid Dimensions
RP2307B and RP2308B
1/4-28 Shaft w/nut Boot NOTE: Remove
shown installed Internal † or pierce decal 1-5/8 in.
(is supplied loose) 1/4-28 to install shaft. Diameter
2-7/16 in.
(62 mm)
9/32 in.
1/2 in. 1 in. (7 mm)
(13 mm) (25 mm)
1-19/32 in.
(40 mm) 2 in.
2-13/16 in. 3/32 in. (51 mm)
(72 mm) (2 mm) 2-1/2 in. † A stud with nut is supplied, loose.
5 in. (64 mm) 1-1/2 in. (38 mm)—1/4-28
(127 mm) part number: 40-01-0055
Solenoid Shown with Plunger Seated (Coil Energized)

RP2309B and RP2310B


Boot Internal † Remove or
1/4-28 Shaft w/nut 1/4-28 pierce decal
Shown with to install shaft. 2 in.
shown installed stud and nut (51 mm)
(is supplied loose) installed. Diameter

9/32 in. 2-7/8 in.


21/32 in. 1-1/8 in. (7 mm) (73 mm)
(17 mm) (28 mm)
2-1/16 in.
(52 mm)
1-1/2 in. 2-1/2 in.
3-9/32 in. 3/32 in. (64 mm)
(83 mm) (38 mm) (2 mm)
3-1/8 in.
7-7/32 in. (79 mm)
(184 mm)
† A stud with nut is supplied, loose.
1-1/2 in. (38 mm)—1/4-28
part number: 40-01-0055
Solenoid Shown with Plunger Seated (Coil Energized)
Note 1. Typical operating temperature for single 15 second operation of the energize coil is less than:
140°F(60°C) ± 10°F (6°C) for 1 in. (25 mm) Stroke Solenoids (70°F/21°C Rise above ambient)
120°F(49°C) ± 10°F (6°C) 1-1/2 in. (38 mm) Stroke Solenoids (50°F/10°C Rise above ambient)
See CAUTION statement on next page and note maximum housing temperature is 185°F (85°C).
Note 2. The energize-coil should not be activated for more than 15 seconds.
Longer energize-coil activation times will damage the solenoid.
Note 3. Allow minimum 15 minutes for cooling between activations of energize-coil to avoid damaging the
solenoid. (Depends on length of time energize coil is energized.)
Note 4. The energize-coil must fully seat the plunger to allow the hold-coil to function properly.
RPS-00092B page 2 of 4
Typical Wiring Diagrams
Typical time-delayed shutdown using a 518PH magnetic switch
(SD85 is optional)

NOTE: In either application if the starter CAUTION: On certain starter solenoids/contactor relays,
hangs, on starters with integral solenoids, the current can feed back through the energize terminal
energize coil remains energized. from the hold coil and provide a parallel path to ground
through the device connected to the energize terminal.

10 AWG*

B
Battery 1 2 3 4 5
ST N.O.
20P-F 20T-F 518PH IG SD85
TATTLETALE®

Start Key
G NC SW SW
1 2 B Switch
Starter
SWICHGAGE® In-Line Motor 10 AWG*
Instruments 10 AWG*
Fuse Starter Contactor
Typical Closed Loop™ Circuit Relay
10 AWG* RP2300 Series
Solenoid ON OFF

Emergency Energize
Stop
Hold

*Wires must be minimum 10 AWG (65/0.3 mm [4.5 mm]) to develop full force. Fuel Lever

Typical time-delayed shutdown using a 760A magnetic switch


(SD85 is optional)
10 AWG*

Existing OFF Turn OFF for


Start Emergency Stop 1 2 3 4 5
System Battery
ON N.O. SD85

Key Switch START


OFF: No power.
ON: Power to hold coil of Starter
fuel solenoid. Motor
START: Power to energize Starter Contactor
coil of fuel solenoid. 760A 10 AWG* 10 AWG*
Time-Delay Relay
20P 20T Before Shutdown
10 AWG* RP2300 Series
G NO NC S B Solenoid ON OFF

Energize
SWICHGAGE® Hold
Instruments

*Wires must be minimum 10 AWG (65/0.3 mm [4.5 mm]) to develop full force. Fuel Lever

Mechanical Installation Operation


1. Bolt the solenoid securely to the mounting bracket. The solenoid coil is connected to the existing engine starter
2. Connect linkage and check for binding. Plunger should move system or an equivalent circuit. A SD85 is recommended. At
freely throughout the complete stroke and be allowed to starting, both the Energize and Hold-in coils are energized. In
“bottom” at the internal stop of the solenoid. the run mode, the Hold-in coil is continuously energized while
DO NOT MOUNT WITH BOOT DOWN. the Energize coil has to be disconnected, reducing the heating
DO NOT APPLY ANY GREASE OR LUBRICATION TO PARTS. effect and power consumption and avoiding damage to the
IMPORTANT: If the plunger does not seat, it will release device.
prematurely when shifted to the “holding” mode of operation. NOTE: Coils that burn out due to improper electrical hookup,
Readjust linkage to lengthen the plunger stroke. Adjust the yoke misadjustment or improper operation are not covered by Murphy
in increments of 1/2 turn until plunger will remain in hold factory warranty.
position.
CAUTION: The solenoid housing is hot to the
Electrical Installation touch. A temperature rise to 185°F (85°C) is
1. Refer to the diagrams above for typical electric wiring. permissible.
2. Use minimum 10 AWG [65/0.3 mm (4.5 mm)] wire size, as
noted in the wiring diagrams. A smaller wire will reduce the NOTE: A cool down period of 15 minutes minimum should be
current available and thus the pulling force. Wire length must allowed between energized pull in cycles.
be kept to a minimum.
RPS-00092B page 3 of 4
Accessories
RPS Linkage Parts and Assemblies

1-1/2 in.
Threaded Rod (38 mm)
(40-05-0315)
1/4-28 Threads

SD85: Solenoid Drive Time Delay


The SD85 is used when the solenoid is duty cycled for short time
RPS 90° Ball Joint periods such as 2-position throttle operation. It also provides
(00-00-2458) 1/4-28
Threads enhanced operational control for normal on-off applications. The
1-1/4 in. SD85 activates both coils of the solenoid for a short time then de-
(32 mm) energizes the Energize-coil. The Hold-in coil remains energized.
3/8 in.
(9 mm)
SD85: Specifications
1-1/4 in.
Input Voltage 8 to 30 VDC
(32 mm) Current Ratings:
40 ma standby (quiescent) 8 to 30 VDC
RPS In-Line Ball Joint (00-00-2457) 75 Amps Pull-in @12 VDC
1 Amps Hold @ 12 VDC
2 in. 37.5 Amps Pull-in @ 24 VDC
(51 mm)
0.5 Amps Hold @ 24 VDC
Terminal #3 2 Amps Maximum
3/8 in.
(9 mm) Terminal #5 112.5 Amps Maximum during Pull-in
2-1/4 in.
(57 mm)
1/4-28 Threads

Clevis Yoke Bead Chain Assemblies


2-3/16 in.
65-01-0110 (56 mm)
Mounting Holes
3/16 in. (5 mm)
diameter 2-places

12 inch
(300 mm) 2-1/2 in. (64 mm)
Chain Mounting Holes
3 in. (76 mm)

SD85 Terminal Block


1 2 3 4 5
Clevis Yoke Assembly 1/16 in.
(2 mm) 10 ga.
65-01-0108 diameter 10 ga.
Energize

1/16 x 3/8 10 ga.


Ground

7/8 in. Cotter Pin NC


Hold

TATTLETALE®
(22 mm) B Option
1/4-28
Thread Control
10 ga.

Switch
5/8 in.
(16 mm) (continuous HOLD
power to #2 and
2 in. temporary PULL
(51 mm) 12-24 VDC power to #4)

1/4 in. (6 mm) diameter NOTE: Wires designated 10 ga. must be


Clevis Yoke Solenoid at least 10 AWG [65/0.3 mm (4.5 mm)] to
develop full force.

CONTROL SYSTEMS & SERVICES DIVISION FRANK W. MURPHY, LTD. MACQUARRIE CORPORATION
P.O. Box 1819; Rosenberg, Texas 77471; USA Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. 1620 Hume Highway
+1 281 633 4500 fax +1 281 633 4588 +44 1722 410055 fax +44 1722 410088 Campbellfield, Vic 3061; Australia
e-mail sales@fwmurphy.com e-mail sales@fwmurphy.co.uk +61 3 9358 5555 fax +61 3 9358 5558
FW Murphy
MURPHY DE MEXICO, S.A. DE C.V. www.fwmurphy.co.uk e-mail murphy@macquarrie.com.au
P.O. Box 470248
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje MURPHY SWITCH OF CALIFORNIA
Tulsa, Oklahoma 74147 USA
San Luis Potosí, S.L.P.; México 78384 41343 12th Street West
+1 918 317 4100 +52 444 8206264 fax +52 444 8206336 Palmdale, California 93551-1442; USA
D
RE

fax +1 918 317 4266 GI


E

Villahermosa Office +52 993 3162117 +1 661 272 4700 fax +1 661 947 7570
STER

USA–ISO 9001:2000 FM 28221


e-mail sales@fwmurphy.com e-mail ventas@murphymex.com.mx e-mail sales@murphyswitch.com UK–ISO 9001:2000 FM 29422

www.fwmurphy.com www.murphymex.com.mx www.murphyswitch.com


In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
Printed in U.S.A.
RPS-00092B page 4 of 4

You might also like