Professional Documents
Culture Documents
C A
COLUMN LINE 1. All loading conditions are examined and only maximum/minimum H or V and the
corresponding H or V are reported.
2. Positive reactions are as shown in the sketch. Foundation loads are in
opposite directions.
3. Bracing reactions are in the plane of the brace with the H pointing away
from the braced bay. The vertical reaction is downward.
4. Building reactions are based on the following building data:
Width (mm) = 10800
Length (mm) = 35710
Eave Height (mm) = 7000 (F.F.L)
Roof Slope (rise/100) = 1:10
Collateral Load (kN/m2) = 0.05
Live Load (kN/m2) = 0.57
Wind Speed (m/s ) = 160
H H Wind Code = MBMA 96
Closed/Open C
V V Importance Wind = 1.00
Seismic Zone = C
RIGID FRAME: BASIC COLUMN REACTIONS (kN)
Frame Column -----Dead---- --Collateral- -----Live---- --Wind_Left1- -Wind_Right1- --Wind_Left2-
Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert
1* C 1.0 8.0 0.2 1.2 2.7 14.1 -28.7 -55.4 21.1 -6.6 -34.7 -44.2
1* A -1.0 8.0 -0.2 1.2 -2.7 14.1 -21.1 -6.6 28.7 -55.4 -15.0 4.7
2* C 1.6 11.3 0.4 2.3 4.9 26.1 -33.1 -72.9 28.6 -13.4 -44.4 -52.0
2* A -1.6 11.3 -0.4 2.3 -4.9 26.1 -28.6 -13.4 33.1 -72.9 -17.3 7.5
CUSTOMER : NLC
JOBSITE LOCATION : TORKHAM
DRAWING TITLE : DWG.NO.
C
X-Bracing X-Bracing
B C C C C B
10800 OUT-TO-OUT OF STEEL
5400
B
A A
5400
B C C C C B
X-Bracing X-Bracing
A
555
555