entry panel
FB00337-EN
PROGRAMMING MANUAL
MTMA/IP - MTMV/IP
General warnings
• Important personal safety instructions: READ CAREFULLY!
• Installation, programming, commissioning and maintenance must only be performed by qualified and experienced
personnel in compliance with applicable regulations.
• Wear antistatic shoes and clothing if working on the control board.
• Keep hold of these warnings.
• Always disconnect the electrical power supply during cleaning or maintenance.
• This product should only be used for the purpose for which it was explicitly designed. Any other use is consi-
dered dangerous.
• The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
MTMA/IP MTMV/IP
4 A D A
C ❷ C ❷
Page 2 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Description of LEDs
A Yellow LED - Conversation in progress.
B Green LED - Door open.
C Blue LED - System busy.
4 Red LED - Call in progress.
Error alerts
LED on, LED flashing, LED off
Problem Red Green Yellow Blue Possible causes
Incorrect installation, near heat sources,
High temperature
hardware failure
CAT5 cable interrupted or not connected,
Ethernet connection incorrect DATA connection, switch not
connected, faulty Ethernet port
Incorrect configuration, partial or incom-
Error in configuration data
plete programming
Audio or video service unavai- Server cannot be reached or is switched
lable, SIP registration failed off, incorrect SIP account
Configuration and commissioning via WEB interface and PCS/XIP
Assign your PC an address belonging to the same subnet as the device. The default IP address is 192.168.1.5
with netmask 255.255.255.0.
A
Switch PoE
192.168.1.1
.5 00
.1
168
192.
VAS/101
192.168.1.1
1.5 00
8.
M1 M2
.16
192
PASSWORD
On the configuration web pages, there is no scroll
bar on the right. To scroll through web pages, press
••••••
and hold the left-hand mouse button and drag. On
your smartphone or tablet, use your finger to drag
Language Enter
on the screen.
Page 4 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
System Help Exit
System
System Technical information identifying the characteristics of
MODEL the device, the hardware and software versions and the
Date and Time
MTMV/IP SIP account status.
Network N.B. The MTMV/IP, MTMA/IP can be configured as
SN
MASTER from PCS/XIP for ‘Serverless’ systems. Only
SIP
0X00801234 one MTMV/IP, MTMAIP can be configured as MASTER.
Credentials HW VERSION
1.0
Access Control
SW VERSION
Device
2.0.0
Maintenance
ACCOUNT STATUS
Diagnostics Registered
Network Help Exit Network
System CONNECTIONS CAMECONNECT
MAC ADDRESS
[CONNECTIONS]
Date and Time
00:50:56:91:2E:28 [MAC ADDRESS]
Network
MODE MAC ADDRESS of the device - cannot be changed
SIP
Static [MODE]
Credentials IP ADDRESS This allows you to choose the type of addressing from:
Access Control 192.168.71.102 DHCP the device’s IP address is assigned by the DHCP
Device NETMASK server (for future use);
255.255.255.0 STATIC (default), the device’s IP address is assigned
Maintenance
GATEWAY
manually.
Diagnostics
192.168.71.1 [IP ADDRESS]
DNS
If you have chosen to use a static IP, enter the IP address
of the device, which must belong to the same subnet
as the router and the other devices connected (default
address: 192.168.1.5).
[NETMASK]
If different from the default, specify the subnet mask.
[GATEWAY]
Specify the default gateway for the home network.
Page 5 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
[DNS]
Enter a valid DNS address if you want to enable the
CAMEConnect connection (only on MTMV/IP, MTMA/IP
configured as MASTER).
Diagnostics
SIP Help Exit SIP
System ACCOUNT TRUNKS FEATURES NODE STATE
[ACCOUNT]
Date and Time
USERNAME For a NON MASTER device, only this section appears
Network 00800000001
SIP
[USERNAME]: SIP username assigned by PCS/XIP to
PASSWORD
the device.
Credentials [PASSWORD]: (for future use).
Access Control
NAME DISPLAYED [NAME DISPLAYED]: username assigned by PCS/XIP
MTMV IP to the device.
Device
SERVER
[SERVER]: server IP address assigned by PCS/XIP
Maintenance 192.168.61.19
[SERVER TYPE]: (for future use)
If the configuration is correct and the SIP server is active,
Diagnostics SERVER TYPE
on the [SYSTEM] page, the [ACCOUNT STATUS] heading
XIP server will show [REGISTERED].
Page 6 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
SIP Help Exit
[TRUNKS] only for devices configured as MASTER
List of servers present in the system.
System ACCOUNT TRUNKS FEATURES NODE STATE
The icon on the right indicates whether the device and
Date and Time relative subsystem can be reached (green) or cannot
Network ETI/miniSER/Domo XIP local be reached (red).
192.168.61.123
SIP
Credentials
Access Control
Device
Maintenance
Diagnostics
Reload
SIP Help Exit
[FEATURES] only for devices configured as MASTER
System ACCOUNT TRUNKS FEATURES NODE STATE [RING TIME]: ring time after which the user called will
Date and Time RING TIME
be considered absent.
30 [RING TIME WITH CALL FORWARDING]: ring time, with
Network
RING TIME WITH CALL FORWARDING
call forwarding on CameConnect active, after which the
SIP
20
user called will be considered absent and forwarding
Credentials will be activated.
Activation codes
50
In the [ACTIVATION CODES] section, you can see and
Device edit the numerical DTMF codes assigned to the Door
Maintenance
AUX1
Opener, Aux1 and Aux2 commands.
53
Diagnostics AUX2
54
Page 7 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
SIP Help Exit [NODE STATE] only for devices configured as MASTER
List of system SIP VoIP devices and their registration
System ACCOUNT TRUNKS FEATURES NODE STATE
status in relation to the MTMV/IP, MTMA/IP MASTER
Date and Time entry panel.
Network Green: registered device
NOTE TYPE
Red: non-registered device.
SIP All
Under the heading [NOTE TYPE], you can filter the list
Credentials of devices by type.
Futura IP 1.1
Access Control Unit IP 1
Device
Futura IP 2.1
Unit IP 2
Maintenance
Diagnostics Reload
CREDENTIALS Help Exit Credentials
System LICENSES XIP RECEIVERS XIP MOBILE GENERIC SIP
[LICENSES]
Date and Time
List of licenses entered and available (for MTMV/IP,
Network UNIT DESCRIPTION CREATION INSERTION QTY
MTMA/IP MASTER only). By default, each MTMV/IP,
SIP
XIPMakeLic
2016-05-13 2016-05-18
MTMA/IP MASTER entry panel has 4 licenses included,
APP mobile app 5
UA license
12:45:20 7:45:20
which can be used as both APP and GST licenses.
Credentials
Select [REQUEST] to obtain the device identification data
Access Control Reload needed to apply for additional licenses.
Any string included under the [DESCRIPTION] heading
Device License request
DESCRIPTION is added to the device identification file.
Maintenance Request
In the [UPLOAD LICENSE] section, it is possible to add
Diagnostics License Upload
the additional licenses required: press [UPLOAD] and
FILE NAME
Page 8 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
CREDENTIALS Help Exit
[XP RECEIVERS] only for devices configured as MASTER
List of XIP type devices (SIP receivers), which do not re-
System LICENSES XIP RECEIVERS XIP MOBILE GENERIC SIP
quire a license and use the MTMV/IP, MTMA/IP MASTER
Date and Time entry panel as the registration server.
Network UNIT DESCRIPTION SIP USERNAME
Credentials 20050 [IP PORT]: (default 20050) this is the MASTER device
port.
Access Control DESCRIPTION IP ADDRESS L3 ADDRESS STATE
For MTMV/IP, MTMA/IP MASTER entry panels only, there
Device
MTMV/IP 1 192.168.61.55 14680320 is a list of SLAVE devices. The green icon indicates that
Maintenance the SLAVE device is connected to the MASTER device.
MTMV/IP 2 192.168.61.98 327680 The red icon indicates that the SLAVE device is not
Diagnostics
Reload
connected to the MASTER device.
Page 10 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
ACCESS CONTROL Help Exit
[USERS]
The access control users are listed under this heading.
System MASTER/SLAVE USERS
Network
users to view.
SURNAME
SIP
[SURNAME]: to search by surname, select [RELOAD].
BADGE CODE [BADGE CODE]: to search by badge code, select [RE-
Credentials
LOAD].
Access Control The search results appear at the bottom of the page.
SURNAME NAME GROUP
Device
User 1 IP unit
From a MASTER device, select by a user to change
Maintenance status (active or non active), the badge code or numeric
Diagnostics User 2 Unit IP2
access code.
The authorisations for routes and openings are defined
Reload by PCS/XIP.
DEVICE Help Exit Device
System AUDIO/LED MULTIMEDIA PARAMETERS
[AUDIO/LED]
Date and Time
You can change the volume of the speaker, the mi-
Network crophone (only if really needed, for example in special
SIP
environmental conditions) and the backlighting of the
entry panel keys.
Credentials
Access Control
Device
Maintenance
Diagnostics
Page 11 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
SIP 1.2.0
MTMKB SW VERSION
Credentials 1.0.0
MTMDY SW VERSION
Access Control 2.0.0
MTMRFID SW VERSION
Device
1.2.0
Maintenance
Diagnostics
Page 12 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Maintenance Help Exit
[UPDATE] for the firmware of the connected devices.
System INFO SYSTEM
Press [SELECT MODULE] to choose which module to
UPDATE
CONFIGURATION
update, and select the firmware update file from your
Date and Time
PC. Start the process.
Network
SELECT MODULE
SIP
Main Module MTMKB module
Device
Maintenance
Diagnostics
Maintenance Help Exit
[SYSTEM CONFIGURATION] restore the default settings
System
for the main module and connected accessories by
choosing [GLOBAL].
INFO UPDATE SYSTEM
CONFIGURATION
Date and Time
Network
RESET TO FACTORY DEFAULTS
SIP
Credentials
Global
Access Control
Device
Maintenance
Diagnostics
Page 13 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Error
[LOG FILES]
SIP
You can generate data files to identify the causes of
MODE
Credentials
Remote
faults.
Access Control
IP ADDRESS [LOG LEVEL]: you can choose the accuracy and type
of LOG file.
Device [MODE]:you can choose the location for saving the LOG
Maintenance
Save Reload file including:
[Local-RAM]: the file is saved in the device’s non-per-
Diagnostics
manent memory
[Local-FLASH]: the file is saved in the device’s internal
memory (capacity is limited)
[Remote]: the file is saved in a remote server
[IP ADDRESS]: specify the IP address of the remote
server.
Operations on PCS/XIP
The device is part of a system based on the Xip system. The system structure must be built using PCS/XIP software.
Page 14 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Talk time (s) 60
Create the system structure as required: to insert the IP entry panels, drag the MTMV IP modules for video or MTMA
IP for audio only from the list on the right . Select the devices inserted and complete the properties ; the
following fields are mandatory: ID and IP Address . Add the accessory modules, for example the MTM8C
button module , define its layout and set the calls corresponding to each key.
Complete the configuration of the other devices and proceed with system programming.
Regulatory references The product complies with the applicable reference directives.
Dismantling and disposal. Dispose of the packaging and the device properly at the end of its life cycle, according to the regulations in force in the country
where the product is used. The recyclable components bear the symbol and code for the material.
THE DATA AND INFORMATION PROVIDED IN THIS MANUAL ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT PRIOR NOTICE. MEASUREMENTS, UNLESS OTHERWISE
INDICATED, ARE IN MILLIMETRES.
Page 16 - Manual code: FB00337-EN ver. 1 10/2016 © CAME s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Came S.p.A.
Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c
31030 Dosson di Casier 33079 Sesto al Reghena
Treviso - Italy Pordenone - Italy
(+39) 0422 4940 (+39) 0434 698111