Ericsson RBS6102 Power Parameter Configuration:

FOR RBS6120 with RUS (feeder)


1- Before define power parameters Use OMT 52 to change both charge mode and battery type
into User defined from configuration tap.
2- User upper version from OMT for Example OMT77 to complete other power parameters.

 BLVD and LLVD

Batteries Types Normal Site (Less than 2 High cascaded site (More than or
cascade) Equal 2 sites)

Huawei Lithium 100A BLVD:44V BLVD:44V

LLVD :45V LLVD :48V

ChinaShoto Lithium 100A BLVD:44V BLVD:44V

LLVD :45V LLVD :47V

Narada Lithium 100A BLVD:45V BLVD:45V

LLVD :46V LLVD :47.4

For Example, for Huawei Lithium Battery 100Ah: (normal site not cascaded)
3- Then define float and Boost voltage as per below:

Open battery type parameters and set float and elevated voltage

Parameters Standard Value


Huawei China Shoto Narada
Single battery Capacity 100 Ah
100 Ah 100 Ah
Equalized charge voltage 53.5 V
54 V 54.1 V
Float charge voltage 53.4 V
52 V 54 V
Standard charge current 0.2C
0.2C 0.2C

For Example, for Huawei Lithium Battery 100Ah: (normal site not cascaded)
4- Then let batteries charge and check PSU and PFU output voltage to match it with parameters.

For Example, for Huawei Lithium Battery 100Ah:

For Example, for Chinashoto Lithium Battery 100Ah:


FOR RBS6120 with RRUS (Fiber)

 For fiber RBS6102 (RRUs) please use OMT52 to create IDB with RUs and install it at Master DUG
then enter to DUG using OMT77 and modify RUs to RRUs.
 Enable Walk in parameter at rectifier setting.
 Adjust battery rated capacity according to actual number of batteries

For Example: if we have 4 batteries 100Ah rated capacity will be 400Ah