You are on page 1of 4

Power Coil

DATASHEET
250W Subsea Power Puck (SPP)

General description Main features


The 250W SPP is a contactless connector • DC to DC wireless power transfer
designed to: • High efficiency
1) Power transfer • Up to 250W load
2) 100Mbit Ethernet • Inrush limitation
3) Galvanic sealed step up/down, fixed • Over temperature protection
voltage or CC/CV charging algorithm • Overload protection
for battery configuration 4S to 12S. • 100Mbps Ethernet connection with
80Mbps minimum data transfer
The system consists of a Primary side (1) and • 48VDC input voltage
a Secondary side (2). • 36VDC nominal output voltage
• 100- 600m depth rating
• Gigabit optional add-on puck

Doc no: 500431-TD-0020


Rev no: 0.95 www.subseausb.no Page 1
Date: 25.01.2023
R
Power Coil

GENERAL ELECTRICAL CHARACTERISTICS FOR 250W FAMILY


All parameter not mentioned are measured with axial distance= 0mm (air), Ta=25ºC and Vin= 48VDC unless otherwise noted. Primary side is
tested together with secondary side configured as 36V DC.

Parameter Min Typ Max Unit Comment


Vin DC -5% 48 +5% VDC Includes input voltage protection*
Inrush current at start-up (input current) 2.5 A

Pout 0 250 W With 36VDC output.


Output voltage will affect the max output power
Max load step from 0W load 250 W Rise time > 50ms
Max load drop from 250W load 250 W Fall time > 50ms

Power draw no load, axial distance=0mm 2.5 W No Ethernet Interface


Efficiency 48VDC 50W 85 % Product under development. Must be tested
Efficiency 48VDC 150W 88 % Product under development. Must be tested

Start-up time power 5 sec


Connector Type 6 Pin Hybrid Bluetrail 20A https://www.bluetrailengineering.com/product-
page/cobalt-series-bulkhead-connector
Refer to the pinout drawing under for the Cobalt 6 pins
hybrid bulkhead connector (at the mating face of the
connector)
* Input voltage has ESD and polarity protection, and a regulated input of 48 (+- 5%) VDC is necessary.

ELECTRICAL CHARACTERISTICS SECONDARY SIDE


A 250W Subsea Power Puck is either preconfigured as a
1. Fixed voltage supply or
2. Battery charger
In Fixed Voltage Configuration the 250W SPP supplies a preconfigured Fixed Voltage. The table below shows typical
values for a secondary side in fixed voltage supply mode.
All parameter not mentioned are measured with axial distance= 0mm (air), Ta=25ºC and with standard primary side. Input voltage to the primary
side is 48VDC.

Parameter Min Typ Max Unit Comment


Vout DC* -5% 48V +5% VDC Fixed voltage
Pout 0 250 W Product under development. Must be tested
Iout 0 5.2 A Product under development. Must be tested
Iout limit at overload** 6 A Product under development. Must be tested
Max load step from 0W load TBD W Rise time > 50ms
Max load drop from 250W load TBD W Fall time > 50ms

Efficiency 48VDC 50W 85 %


Efficiency 48VDC 150W 88 %

* Output voltage can go outside limit with rise/fall time < 50ms
** Current above this limit will result in voltage drop and shut down
Extreme load above limit or short circuit in normal operation can
destroy the unit
Power Output Configuration Alternatives
In Battery Charger Mode the secondary side will
deliver an output voltage that matches the
battery capacity and battery configuration. The
250W SPP supports battery charging using CC/CV
algorithm for battery configuration 4S to 12S.
The table below shows default minimum and
maximum charging voltages for the different
battery configurations, but these limits can be
customized.

Doc no: 500431-TD-0020


Rev no: 0.95 www.subseausb.no Page 2
Date: 25.01.2023
R
Power Coil

Battery Configuration and power alternatives:


Battery Configuration Min Nominal Max Unit Comment
Li-ion 4S 11.2 14.0 16.8 VDC
Li-ion 5S 14.0 17.5 21.0 VDC
Li-ion 6S 16.8 21.0 25.2 VDC
Li-ion 7S 19.6 24.5 29.4 VDC
Li-ion 8S 22.4 28.0 33.6 VDC
Li-ion 9S 25.2 31.5 37.8 VDC
Li-ion 10S 28.0 35.0 42.0 VDC
Li-ion 11S 30.8 38.5 46.2 VDC
Li-ion 12S 33.6 42.0 50.4 VDC

The table below shows typical values for 4S configuration.

Parameter Min Typ Max Unit Comment


Vout DC* 11.2 14.0 16.8 VDC Battery charging. CC/CV.
Pout TBD W Product under development. Must be tested.
Iout 0 7 A Product under development. Must be tested.
Iout limit at overload** TBD A
Max load step from 0W load TBD W Rise time > 50ms
Max load drop from 250W load TBD W Fall time > 50ms

Efficiency 3.5A charging TBD %


Efficiency 7 A Charging TBD %

* Output voltage can go outside limit with rise/fall time < 50ms.
** Current above this limit will result in voltage drop and shut down
Extreme load above limit or short circuit in normal operation can destroy the unit
Please contact sales@subseausb.no for other voltage or charging configuration.

COMMUNICATION INTERFACE
The 250W SPP comes in two versions, with or without transparent Ethernet interface.
Parameter Min Typ Max Unit Comment
Start-up time Ethernet 90 sec
Data rate Ethernet*** 80 Mbps See note***
Default IP Primary Side 192.168.1.253 / 24
Default IP Secondary Side 192.168.1.254 / 24
*** Typical values for ordinary TCP/IP traffic test setup. Real-life data rate is dependent on system setup, protocols used and external devices. Link is semi-transparent
with layer-2 processing. Testing should be performed to verify support for Ethernet types/protocols other than standard ARP and IP.
Extreme load above limit or short circuit during normal operation can destroy the unit

DISPLACEMENT
Parameter Min Typ Max Unit Comment
Lateral displacement TBD
Angular displacement TBD
Axial distance tolerance 0 4 mm 5 mm at reduced capacity
Rotation during operation 0 360 °

ENVIRONMENTAL
Parameter Min Typ Max Unit Comment
Operating temperature -10 +45 °C Need cooling with high ambient temperature
Storage temperature TBD °C
Design water depth 400 m
Rated work press in Bar 40 BAR

Doc no: 500431-TD-0020


Rev no: 0.95 www.subseausb.no Page 3
Date: 25.01.2023
R
Power Coil

MECHANICAL DIMENSIONS
Parameter Unit Comment
Weight in Air 0.7 kg
Submerges Weight 0.4 kg
Volume 0.3 dm3

Dimensions in figure below is in [mm].

ORDERING INFORMATION
Article Nr. PRODUCT CODE Product Name Comment
Primary Connector for Charge Station 48VDC input power
EA0456(BB8290) USB-F30-100-481-Pri F30-Pri. PowerPuck 250W 48VDC, 100Mbps Primary Connector, 80Mbit sec, 48VDC supply

Secondary Connector for Drone Side – Fixed Out put


EA0458 (BB8813) USB-F30-100-481-Sec F30-Sec. PowerPuck 200W 24VDC, 100Mbps Secondary Connector, 80Mbit sec, 24VDC fixed output
EA0459 (BB8814) USB-F30-100-481-Sec F30-Sec. PowerPuck 250W 36VDC, 100Mbps Secondary Connector, 80Mbits sec, 36VDC fixed output
EA0460 (BB8815) USB-F30-100-481-Sec F30-Sec. PowerPuck 250W 48VDC, 100bps Secondary Connector, 80Mbit sec, 48VDC fixed output

Secondary Connector for Drone Side – With DC/DC and Charge Algoritm CC/CV for Lithium ion
EA0457 (BB8405) USB-F30-100-481-Sec F30-Sec. ChargePuck 7A-4S, 100Mbps Secondary Connector, 80Mbit sec, 4S CC/CV Charge algorithm
EA0461 (BB8816) USB-F30-100-481-Sec F30-Sec. ChargePuck 7A-7S, 100Mbps Secondary Connector, 80Mbit sec, 7S CC/CV Charge algorithm
EA0462 (BB8817) USB-F30-100-481-Sec F30-Sec. ChargePuck 7A-8S, 100Mbps Secondary Connector, 80Mbit sec, 8S CC/CV Charge algorithm
EA0463 (BB8818) USB-F30-100-481-Sec F30-Sec. ChargePuck 7A-10S, 100Mbps Secondary Connector, 80Mbit sec, 10S CC/CV Charge algorithm
EA0464 (BB8819) USB-F30-100-481-Sec F30-Sec. ChargePuck 7A-12S, 100Mbps Secondary Connector, 80Mbit sec, 12S CC/CV Charge algorithm

IP address Configuration
All Subsea-USB systems are delivered with a fixed IP address. The used addresses are listed in table below. It is
recommended to avoid having other equipment in the same network using the same IP address. Other IP
configurations of the Subsea-USB system are however available upon request as special deliveries. The IP
addresses of the Subsea-USB system do not affect the transmission of data and it is not required that the IP
address of the Subsea-USB system lies within the IP range of the network.
Table 1: IP Address
Unit IP Address

Primary side 192.168.1.253 / 24

Secondary side 192.168.1.254 / 24

Doc no: 500431-TD-0020


Rev no: 0.95 www.subseausb.no Page 4
Date: 25.01.2023