You are on page 1of 2

CONFIDENTIAL EE/JUN 2021/EPE491

UNIVERSITI TEKNOLOGI MARA


TEST 1

COURSE : ELECRTICAL POWER AND MACHINES


COURSE CODE : EPE491
EXAMINATION : JUN 2021
TIME : 1 HOUR

INSTRUCTIONS TO CANDIDATES

1. This question paper consists of TWO (2) questions.

2. Answer ALL questions.

3. Do not bring any material into the examination room unless permission is given by the
invigilator.

NAME : ________________________________________________________
GROUP : ________________________________________________________
MATRIC’S NO : ________________________________________________________
LECTURER NAME : ________________________________________________________

COURSE EPE491 TEST 1


Question CO PO Allocated Graded Question CO PO Allocated Graded
Marks Marks Marks Marks

OBE IMPLEMENTATION
Level I Level II Level III
BLOOM’S LEVEL FOR SEM 3
(15%) (30%-50%) (15%-40%)
QUESTION
BLOOM’S LEVEL DOMAIN COGNITIF
FOR TEST 1 COURSE OUTCOME
PROGRAM OUTCOME
LEARNING OUTCOME
ALLOCATED MARKS
QUESTION 1

a) Describe the power delivery process from power plant to the consumer using single line
diagram.
(3 marks)

b) A three-phase, Y-connected, 415 V, 50 Hz generator supplies a fixed three-phase


balanced load connected in parallel as follows:

Load 1: A Y-connected 40 kVAR motor at 0.7 lagging power factor.


Load 2: A -connected 20 hp induction motor at 0.75 lagging power factor.
Load 3: A -connected 20 kW purely resistive load

i) Sketch the single-line diagram of this system.


ii) Calculate the total real, reactive and apparent power taken from the supply source by
all the loads.
iii) Calculate the line current for load 1, load 2, load 3 and the total line current of the
supply source.
iv) Determine the overall power factor of the system.

(12 marks)

QUESTION 2
a) Draw and label the equivalent circuit of a practical transformer.
(3 marks)

b) A transformer has the following details: 20kVA, 8000/240V, 50Hz. The open circuit test
performed on the primary side of the transformer and short circuit test were performed
on the secondary side of the transformer, and the following data were taken.

Table Q2b

Open circuit test Short circuit test


VOC = 8000V VSC = 415 V
IOC = 0.2A ISC = 2.2 A
POC = 400 W PSC = 210 W

i) Based on the results, determine the impedance of the transformer referred to


secondary side and sketch the approximated equivalent circuit.
ii) The full load copper losses.
iii) Find 75% full load efficiency with 0.95 pf lagging.
(12 marks)

END OF QUESTION