ARCHITECTURAL ABBREVIATIONS LIST MATERIAL DESIGNATIONS ARCHITECTURAL SYMBOLS LIST SPECIFIC SYMBOL LIST

DRAWING TITLE FLOOR ELEVATION TARGET THE SYMBOLS BELOW APPLY TO ALL ARCHITECTURAL DRAWINGS :
EARTH/ COMPACT FILL
A E L R
DRAWING NUMBER 200 LEVEL FIRE EXTINGUISHER (F.E.) & CABINETS: NOTE: CONTRACTOR TO COORD. &
AB ANCHOR BOLT E EAST L LENGTH R RISER
GRAVEL/ POROUS FILL 200'-0"
ABV ABOVE EA EACH LAB LABORATORY RAD RADIUS DRAWING TITLE PROVIDE WOOD BLOCKING FOR ALL
A/C AIR CONDITIONING EB EXPANSION BOLT LAM LAMINATE(D) RB RUBBER BASE BUILDING DATUM ELEVATION CP
FE-01 RECESSED CABINET W/ FIRE EXTINGUISHER ITEMS LISTED BELOW
ACC
ACT
ADA
ACCESSIBLE
ACOUSTICAL TILE
AMERICANS WITH DISABILITIES
EC
EL
ELEC
EXPOSED CEILING
ELEVATION
ELECTRIC(AL)
LAT
LAV
LB
LATERAL
LAVATORY
POUND(S)
RD
REV
RECP
ROOF DRAIN
REVISION, REVISE(D)
RECEPTACLE
ROCK
1 View Name
A6-2 1 1/2" = 1'-0" [REF: 1/ A4-1] REFERENCE WORK POINT TARGET
(SEE 3/A6-1 FOR MOUNTING HEIGHT)

ADD ADDENDUM ELEV ELEVATOR LBL LABEL REF REFERENCE CONCRETE: CAST IN PLACE/ PRECAST
ADD'L ADDITIONAL EMER EMERGENCY LH LEFT HAND REFL REFLECT(ED), (ING) BACK REFERENCE TARGET
LOCATION (I.E. REFER TO 1/A4-1 TACK BOARDS:
ADJ ADJUSTABLE ENCL ENCLOSE (URE) LIB LIBRARY REINF REINFORCE(D), (ING) SAND/ MORTAR/ PLASTER
AFF ABOVE FINISHED FLOOR ENG ENGINEER LIN LINEAR REQD REQUIRED FOR TARGET 1/A6-2 LOCATION) MAJOR REFERENCE WORK
POINT TO LOCATE
TB-3 3'-0" (W) X 4'-0" (FIXED) NOTE: MOUNT ALL CHALK, MARKER,
ALT ALTERNATE EQ EQUAL LL LIVE LOAD RFI REQUEST FOR INFORMATION DRAWING SCALE AND TACK BOARDS SO THAT TOP
ALUM ALUMINUM EQUIP EQUIPMENT L.P. LOW POINT RH RIGHT HAND CONCRETE MASONRY UNIT DIMENSIONS TB-4 4'-0" (W) X 4'-0" (FIXED) EDGES ALIGN WITH TOP EDGE OF Department of Capital Planning & Policy
AP ACCESS PANEL EWC ELECTRIC WATER COOLER LT LIGHT RM ROOM SHEET NUMBER
APPD APPROVED EXP EXPOSED LTG LIGHTING RO ROUGH OPENING
REVISION TARGET ADJACENT DOOR HEADS Bureau of Asset Management
COMMON/ FACE BRICK NORTH ARROWS
APPROX APPROXIMATE EXH EXHAUST LTL LINTEL MARKER BOARDS: Notice: This drawing has not been published and is the
EXIST EXISTING N REVISION DESIGNATION sole property of Cook County. It is loaned to the borrower
ARCH ARCHITECT(URAL) LVR LOUVER
AUD AUDITORIUM EXP EXPANSION CUT STONE 1 MB-3 3'-0" (W) X 4'-0" (FIXED) for their confidential use only. In consideration of the loan
EXT EXTERIOR TRUE NORTH ARROW REVISION CLOUD of this drawing, the borrower promises and agrees to
AUTH AUTHORIZED
AUTO AUTOMATIC M S MARBLE
MB-4 4'-0" (W) X 4'-0" (FIXED) return it upon request and agrees that it shall not be
A/V AUDIO/VISUAL reproduced, copied, loaned, or otherwise disposed of
M METER(S) S SOUTH directly or indirectly, nor used for any purpose other than
PROJECT NORTH ARROW
F MACH MACHINE SAFB SOUND ATTENUATION FIRE STEEL COATHOOKS: NOTE: COAT HOOKS LOCATED ON A for which it is furnished, in whole or part.
MAN MANUAL BLANKET ALIGN
FAST FASTENER SEE 4/A6-1 FOR MOUNTING DETAILS. WALL BEHIND A DOOR ARE TYP. 1'-3"
MAS MASONRY SAN SANITARY
FD FLOOR DRAIN ALUMINUM COLUMN LINE GRID & NUMBERS FROM THE CORNER U.N.O.
B FE FIRE EXTINGUISHER
MAT'L MATERIAL(S) SC SEALED CONCRETE
CH-4 (1) 2'-0"(L) PANEL W/ (4) COATHOOKS
MAX MAXIMUM SCHED SCHEDULE NEW COLUMN NUMBER
B/ BOTTOM OF FEC FIRE EXTINGUISHER CABINET
MB MARKER BOARD SEC SECOND ROUGH WOOD
BEL BELOW FFL FINISH FLOOR LINE L CH-12 (1) 8'-0"(L) PANEL W/ (12) COATHOOKS
MECH MECHANICAL SECT SECTION
BTWN BETWEEN FHC FIRE HOSE CABINET FIRE-RATED WALL SYMBOLS
MED MEDIUM SERV SERVICE EXISTING COLUMN NUMBER
BEV BEVELED FHMS FLATHEAD MACHINE SCREW FINISH WOOD
MEMB MEMBRANE SF SQUARE FOOT MISC DEVICE LOCATIONS:
BLKG BLOCK(ING) FHWS FLATHEAD WOOD SCREW
MTL METAL SGL SAFETY GLASS
X
BLDG BUILDING FIN FINISH(ED) 1 HR RATED WALL
MEZZ MEZZANINE SHT SHEET PLYWOOD
BM BEAM FLG FLASHING TV-1 TELEVISION (SEE A6-1 FOR MOUNTING HEIGHT)
MFR MANUFACTURE(R), (ED) SIM SIMILAR
BOT BOTTOM FLR FLOOR(ING) 2 HR RATED WALL
MI MILE(S) SK SKETCH SECTION TARGET
BRG BEARING FLUOR FLUORESCENT PARTICLE BOARD TV-2 CONFERENCE ROOM MONITOR (SEE A6-1 FOR MOUNTING HEIGHT)
MIN MINIMUM S.J. SEALANT JOINT
BRK BRICK FR FRAME(D), (ING) BUILDING SECTION TARGET
MISC MISCELLANEOUS SPEC(S) SPECIFICATION(S) PANIC BUTTON (MOUNTED IN MILLWORK)
BS BOTH SIDES FS FULL SIZE X
3 HR RATED WALL PB-1
MO MASONRY OPENING SQ SQUARE BATT INSULATION
BSMT BASEMENT FT FOOT (FEET) AX-X
MTD MOUNTED SSK SERVICE SINK SECTION NUMBER
BTU BRITISH THERMAL UNIT FTG FOOTING
MULL MULLION SST STAINLESS STEEL WALL SYMBOLS
BUR BUILT-UP ROOFING FUR FURRED, FURRING RIGID INSULATION SHEET NUMBER
FUT FUTURE STD STANDARD
FV FIELD VERIFY STIFF STIFFENER
STL STEEL SPRAYED-ON FIREPROOFING NEW DOOR
X DETAIL SECTION TARGETS
STOR STORAGE
C STRUCT STRUCTURE, STRUCTURAL
AX-X
SECTION NUMBER EQUIPMENT & FURNISHINGS SCHEDULE
C CENTER G N SUSP SUSPEND, SUSPENDED SEALANT WITH BACKER ROD
EXISTING DOOR
SHEET NUMBER Type Mark Description Count
CAB CABINET N NORTH SYM SYMMETRY, SYMMETRICAL X
G GRAM
CAP CAPACITY NAT NATURAL GYPSUM DRYWALL AX-X
GA GAGE, GAUGE ACCESS PANEL @ 6' AFF TYP. BINS-01 BIN, SHREDDING, SECURE 1
CEM CEMENT NC NO CEILING
GALV GALVANIZED
CER CERAMIC NIC NOT IN CONTRACT CASU-01 CART, SUPPLY 6
GC GENERAL CONTRACTOR METAL LATH WITH PLASTER DETAIL TARGET
CFT CUBIC FOOT (FEET) NO. NUMBER T NEW GLASS PARTITION CASU-02 CART, SUPPLY 2
GD GRADE, GRADING
CG CORNER GUARD NOM NOMINAL CASU-03 CART, PROCEDURE, RESUSCITATION 1
GFR GLASS FIBER REINFORCED T TREAD
CHAM CHAMFER NRC NOISE REDUCTION TERRAZZO DETAIL NUMBER
GFRC GFR CONCRETE T/ TOP OF NEW PARTITION CAV-01 AV CABINET 1
CIR CIRCLE COEFFICIENT
GKT GASKET(ED) T&B TOP & BOTTOM CH-4 COAT HANGER 3
CIRC CIRCUMFERENCE NTS NOT TO SCALE
CJ CONTROL JOINT
GL GLASS, GLAZING TEMP TEMPERATURE GLASS 1 SIM EXISTING PARTITION CH-12 COAT HANGER 1
GPDW GYPSUM DRYWALL TERR TERRAZZO A6-2
CK CAULKING
GT GROUT O T&G TONGUE & GROOVE
COPM-01 COPIER, PRINTER, MULTIFUNCTION 1
CLASSRM CLASSROOM ACOUSTICAL TIL E COSH-01 CONTAINER, SHARPS 6
GWB GYPSUM WALL BOARD OA OVERALL THK THICK(NESS) PARTITION TO BE
CLG CEILING SHEET NUMBER
GYP GYPSUM OC ON CENTER THRU THROUGH DEMOLISHED DEAE-01 DEFIBRILLATOR, AED 1
CLO CLOSET
CLR CLEARANCE/CLEAR OD OUTSIDE DIAMETER TV TELEVISION ELEVATION DI-01 DIALYSIS MACHINE 15
x x x x FENCE
CLS CLOSURE OFF OFFICE TYP TYPICAL TARGET DISE-01 DIAGNOSTIC SET 1
CM CENTIMETER(S) H OH OVERHEAD BUILDING ELEVATION TARGET
DRCL-01 DIALYSIS RECLINER - NIC 12
CMU CONCRETE MASONRY UNIT O.H. OPPOSITE HAND BUILDING MATCH LINE
H HIGH 1 SHEET NUMBER DRCL-02 DIALYSIS BARIATRIC RECLINER - NIC 1
CO CLEAN OUT OHMS OVALHEAD MACHINE SCREW
HB HOSE BIBB
COEF COEFFICIENT HC HOLLOW CORE
OHWS OVALHEAD WOOD SCREW U 4 A4-1 2
DRDU-06 DRUG DISPENSING UNIT 1
OPNG OPENING DETAIL NUMBER ACCESSIBILITY SYMBOLS ELEC-01 ELECTROCARDIOGRAPH 1
COL COLUMN HCAP HANDICAP UC UNDERCUT
COMB COMBINATION HD HEAD
OPP OPPOSITE 5' - 0" EW-01 EYE WASH 3
UL UNDERWRITER'S 3 INTERIOR ELEVATION TARGET
COMP COMPRESS(ED), (ION), (IBLE) HDW HARDWARE LABORATORY WHEELCHAIR TURNING EW-02 EYE WASH, DRENCH HOSE 2
CONC CONCRETE 1 SHEET NUMBER RADIUS Holabird & Root, LLC expressly disclaims any
CONF CONFERENCE
HEX HEXAGONAL P UNEX UNEXCAVATED FE-01 FIRE EXTINGUISHER CABINET 3 responsibility arising from any unauthorized use of these
HM HOLLOW METAL UNO UNLESS NOTED OTHERWISE
CONN CONNECTION
1 A2-1 1 DETAIL NUMBER GLBH-01 GLOVE BOX HOLDER 7 plans, drawings and notes. Any authorization must be in
HORIZ HORIZONTAL PAR PARALLEL UR URINAL
CONST CONSTRUCTION HP HORSEPOWER PBD PARTICLE BOARD HM-01 HEALTH MONITOR DISPLAY 1 writing.
1
CONT CONTINUOUS OR CONTINUE H.P. HIGH POINT PC PRECAST CONCRETE ACCESSIBLE ITEM MICRO-01 MICROWAVE 1
CONTR CONTRACT(OR) HR HOUR P.D. PLAN DETAIL V ROOM NAME & NUMBER TARGET MOVS-01 MONITOR, VITAL SIGNS 1
This drawing copy may have been reproduced at a size
CONV CONVECTOR HT HEIGHT PED PEDESTAL different than originally drawn. The Owner and Architect
VAPB VAPOR BARRIER NARC-01 CABINET, STORAGE, CLINICAL, NARCOTICS 1
COP COPING HTG HEATING PERF PERFORATE(D) assume no responsibility for use of incorrect scale.
VB VINYL BASE WHEELCHAIR AREA REFU-01 REFRIGERATOR FREEZER, UPRIGHT 1
CORR CORRIDOR HVAC HEATING/VENTILATION/AIR PERIM PERIMETER AOR Drawings are not to be scaled.
VCT VINYL COMPOSITE TILE ROOM NAME OF REFUGE
CPT CARPET(ED) CONDITIONING PERP PERPENDICULAR 101 REUN-01 REFRIGERATOR, UNDERCOUNTER 3
VERT VERTICAL
CRW CURTAIN WALL HW HOT WATER PKG PARKING ROOM SCHT-01 SCALE, HEIGHT 1 Not published - All rights reserved.
VEST VESTIBULE
CS COUNTERSINK HYD HYDRAULIC PL PLATE VIF VERIFY IN FIELD NUMBER SCI-01 SCALE, INTEGRATED 1
CSMT CASEMENT WHEELCHAIR CLEAR
P.L. PROPERTY LINE VT VINYL TILE DOOR TARGET FLOOR AREA STWB-01 STOOL WITH BACK 1
CT CERAMIC TILE I PLAM PLASTIC LAMINATE
CW COLD WATER PLAS PLASTER TAEP-01 EXAM TABLE POWE 1
ID INSIDE DIAMETER
CY CUBIC YARDS
IN INCH(ES) PLBG PLUMBING W 101A ELECTRICAL CONTROL ON DOOR TB-03 TACK BOARD 1
PNL PANEL DOOR NUMBER, (COORDINATE WITH ELECTRICAL DRAWINGS) TB-04 TACK BOARD 1
INCL INCLUDE(D), (ING) W WEST SEE DOOR SCHEDULE
INFO INFORMATION PNT PAINT(ED) TV-01 WALL MOUNTED TV 3
W/ WITH ACCESS BUTTON FOR AUTOMATIC
INSUL INSULATION POL POLISH(ED) PARTITION TYPE TARGET A
WC WATER CLOSET DOOR. ALL DOOR FRAMES WITH TV-02 WALL MOUNTED MONITOR 2
D INT INTERIOR PR PAIR
WD WOOD ACCESS BUTTON TO BE TVAR-01 TV ARM, ARTICULATING 12
INTERM INTERMEDIATE PREFAB PREFABRICATED PARTITION TYPE,
D DEPTH WIN WINDOW D1.1 ELECTRIFIED WHEE-01 WHEELCHAIR 1
PRES PRESSURE S SEE PARTITION TYPES
DB DECIBELS WL WIND LOAD
DBL DOUBLE
J PROJ PROJECTION
W/O WITHOUT A PEDESTAL ACCESS BUTTON FOR
PROT PROTECTION
DEG DEGREE(S) J JOIST WP WATERPROOFING WINDOW TARGET AUTOMATIC DOOR. ALL DOOR
PSI POUNDS PER SQUARE INCH
DEG C DEGREE(S) CELSIUS JAN JANITOR WPT WORKING POINT FRAMES WITH ACCESS BUTTON TO
PT POINT
DEG F DEGREE(S) FAHRENHEIT JC JANITOR'S CLOSET WRSTP WEATHER STRIPPING BE ELECTRIFIED
PTN PARTITION
DEPT DEPARTMENT JCT JUNCTION WT WEIGHT W11 WINDOW TYPE, 1 09/07/2018 ISSUED FOR BID
PVC POLYVINYL CHLORIDE CARD READER ON DOOR FRAME
DET DETAIL JT JOINT WWF WELDED WIRE FABRIC SEE WINDOW SCHEDULE C
PW PAINTED WOOD TO BE ELECTRIFIED OR ON WALL No. Date Issue
DF DRINKING FOUNTAIN
DH DOUBLE HUNG K B101 VIEW WINDOW NUMBER,
RELEASE BUTTON FOR
SEE INTERIOR WINDOW R
DIA DIAMETER KG KILOGRAM(S) Y SCHEDULE AUTOMATIC DOOR (MOUNTED ON
Project Number 15849
DIAG DIAGONAL KIT KITCHEN KEYNOTE TARGET FURNITURE; CONTRACTOR TO
DIM DIMENSION YD YARD
KM KILOMETER(S) COORDINATE WITH FURNITURE Drawn S. DENNY
DIV DIVISION KO KNOCKOUT Q ?
011000.01 KEYNOTE, SEE KEYNOTE LIST SUPPLIER TO CONCEAL ALL
DL DEAD LOAD KS KNEE SPACE WIRING. RUN CONDUIT IN SLAB Checked K. BOYER
QT QUARRY TILE
DN DOWN TO FURNTURE STATION).
QTY QUANTITY Proj. Arch./Eng. K. SCHUSTER
DP DAMP PROOFING TOILET ACCESSORIES TARGET
DR DOOR NEGATIVE PRESSURE MONITOR.
P
DS DOWNSPOUT T1 ALL DOOR FRAMES WITH
DU DWELLING UNIT PRESSURE MONITOR TO BE
DWG DRAWING ACCESSORY NUMBER
ELECTRIFIED.
Provident Hospital - Renal
KEYNOTES LEGEND MASTER LIST KEYNOTES LEGEND MASTER LIST KEYNOTES LEGEND MASTER LIST Dialysis Center

024119.01 REMOVE HM FRAMES & WOOD DOORS 102800.04 GRAB BAR (36")
024119.02 REMOVE METAL STUD AND GBDW WALLS 102800.06 MIRROR - ABOVE COUNTERTOP (SURFACE MOUNTED)
024119.03 REMOVE STEEL SHUTTERS & ASSOCIATED FRAMES & MOTORS 102800.08 PAPER TOWEL DISPENSER
024119.04 REMOVE CMU FOR NEW DOOR 102800.09 SOAP DISPENSER
024119.05 REMOVE ACT FLOORING 102800.10 BABY CHANGING TABLE
024119.06 REMOVE MILLWORK COUNTERTOPS 102800.13 SEMI-RECESSED PAPER TOWEL DISPENSER & WASTE RECEPTACLE; 12-GAL WASTE CONTAINER.
024119.07 REMOVE DOOR & FRAME 122413.01 MANUALLY OPERATED ROLLER SHADES
024119.08 REMOVE FIXED SEATING 224000.01 WATER CLOSET 430 East 51st Place
024119.09 REMOVE VESTIBULE STOREFRONT 224000.02 WATER CLOSET - ACCESSIBLE Chicago, Illinois 60615
024119.10 REMOVE CONC & WOOD PLANTER/SEAT WALL 224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ PIPE COVER
024119.11 REMOVE SUSPENDED ACT CEILING 224000.05 LAVATORY - DROP-IN SINK Project Name
024119.12 REMOVE GBDW SOFFIT 260000.01 DEVICE MOUNTED ON FURITURE. CONTRACTOR TO COORDINATE WITH FURNITURE SUPPLIER TO
024119.13 REMOVE PLASTER CEILING CONCEAL ALL WIRING.
024119.14 REMOVE AND REPLACE ENTRY DOORS
ARCHITECTURAL SYMBOLS &
024119.15 NEW DUCT WORK OPENINGS IN CMU BULKHEAD. SEE MECHANICAL DRAWINGS. USE EXISTING OPENINGS ABBREVIATIONS
WHERE POSSIBLE. PROVIDE NEW LINTELS WHERE NECESSARY.
024119.16 REMOVE DOOR WHILE LEAVING FRAME INTACT. Sheet Name
024119.18 REMOVE EXISTING BOLLARD IN CONFLICT WITH NEW GENERATOR ENCLOSURE.
064116.02
102800.03
PLASTIC LAMINATE LOCKER.
GRAB BAR (42") AND VERTICAL GRAB BAR (18") Drawing No. A1-1
GENERAL NOTES: FLOOR PLANS
1. SEE LS-SERIES DWGS FOR FIRE-RATED PARTITION LOCATIONS.

2. SEE SHEET A7-2 FOR DOOR SCHEDULE.

3. SEE SHEET A7-1 FOR PARTITION TYPES. ALL PARTITION TYPES


ARE D1.1 U.N.O.
S
2
A4-2
4. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS FOR
DIRECTOR JANITOR'S STAFF CHANGING COORD. OF ALL TRADES & SUBS, AND REPORT ANY CONFLICTS
WOMENS MENS OFFICE TELECOM STAFF OR DISCREPANCIES TO THE ARCHITECT.
OFFICE CLOSET TOILET ROOM
107 108 109 111 113
110 112 113B 113A
5. ALL DIMENSIONS ARE LOCATED AT FACE OF FINISH, U.N.O.
A 6. PROVIDE 18" MIN ON LATCH SIDE OF ALL DOORS. ALL DOOR
Department of Capital Planning & Policy
9
122413.01 F9.2 D1.2
S FRAMES TO BE 4" FROM THE CLOSEST PERPENDICULAR Bureau of Asset Management
S 113B 3
A8-3 7 PARTITION, U.N.O.
CONFERENCE D1.2 A6-2 Notice: This drawing has not been published and is the
S
102
064116.02 sole property of Cook County. It is loaned to the borrower
107 108
113A 8 D1.2 SOILED 7. WALLS TO BE FLUSH WITH COLUMN FURRING, U.N.O.
4 CH-4 S for their confidential use only. In consideration of the loan
STORAGE
109 6 110 111 112 113 of this drawing, the borrower promises and agrees to
118 8. PROVIDE BEVELED EDGE STEEL ANGLE PROTECTORS FOR ALL
3 A8-3 1
CORRIDOR return it upon request and agrees that it shall not be
5I 102 PAT. TOILET 1 100B TIME CORRIDOR 100C 5 ITEMS PROJECTING FROM WALL.
F9.2 A8-3 100D reproduced, copied, loaned, or otherwise disposed of
A4-1 114 A6-2 CLOCK 100C A8-1 CLEAN
2 A C D1.2 WATER directly or indirectly, nor used for any purpose other than
CORRIDOR S
SUPPLY 9. MAINTAIN WALL RATING AT RECESSED ITEMS SUCH AS AT
5 118 119 TREATMENT for which it is furnished, in whole or part.
100B 119 EMERGENCY SHOWERS, FIRE EXTINGUISER CABINETS, ETC.
125
114
D1.2
B S MED. PREP. COSH-01 10. PROVIDE MOP SINK WITH WALL GUARD, MOP HOLDER AND
TB-03 115 UTILITY SHELF AT ALL JANITOR CLOSETS.
FE-01 12 6
EXAM F9.2 FE-01 A8-1
COSH-01 D1.2 11. FOR ALL EQUIP. AND EQUIP. BASES IN MECH ROOMS AND OTHER
106 1 S
A4-1 2 106 AREAS SEE THE SPECIFIC ENGINEERING DWGS & SPEC (COORD.
EQUIP. SIZE OF BASES WITH SPECIFIC EQUIP. MFR).
11 TB-04 260000.01 R 11 REPAIR
FOR DOOR 100B D1.4 120 125A
1 S 12. PROVIDE FIBERGLASS GPDW AT WET WALL LOC.
A4-2
A8-3 10
1 5
NURSE 6 A8-2 3
2 A8-2
STATION D1.2 NEW CMU INFILL TO
WAITING S 120 13. MOVABLE FURNITURE IS SHOWN DASHED. FIXED OR BUILT-IN
MATCH EXISTING AT
ROOM MIRROR FURNITURE IS SHOWN SOLID.
D1.4 EXISTING OPENING
101 S 10
A D5.1 FE-01 14. PROVIDE GPDW TRIMLESS ACCESS PANELS (2'-0" X 2'-0") FOR
C 100A.B
1 3
S 4 125B
GPDW CEILING AREAS. MINIMIZE NEED FOR ACCESS PANELS -
A8-1 D1.2 A8-1
S
121 COORD. LOCATION OF ACCESS PANELS WITH OTHER TRADES
A 4 STORAGE 6 Sim FOR ITEMS ABOVE CEILING.
105 126
RECEPTION A C
3 122 LAB 100D A4-1
105 A8-2 9 121 15. FOR STEEL LINTELS AT INTERIOR MASONRY WALLS &
064116.02 2 A8-1 122
100A.A 103 104
4 A8-1 P PARTITIONS - SEE CMU LINTEL SCHEDULE. VERIFY MASONRY
VESTIBULE 2
117 123 124 WALL WIDTH & CLEAR SPAN (OPENING WIDTH). PROVIDE
100A APPROPRIATE LINTEL AND COORD. WITH OTHER TRADES.
6 7 117A 2
A 8 127
A6-2
D1.2 16. FILL ALL SLAB PENETRATIONS WITH FIRESTOPPING MATERIAL
F9.2 F9.2 5 S
(SEE SPEC.)
122413.01 F9.2 F9.2 D40.2
S
17. COORDINATE ALL FIRE EXTINGUISER CABINETS INTO GPDW
D PARTITIONS.
DIETITIAN SOCIAL TREATMENT PRIVATE W.C. ELECTRICAL MECHANICAL
103 WORKER AREA 117A 123 124 18. PROVIDE SHADES AT ALL INT. AND EXT. WINDOWS, U.N.O.
PAT./ISOLATION
104 1 116 117
19. ALL H.M. DOORS & H.M. FRAMES TO BE PAINTED.
1 A4-1 2 3
20. ALL UNFINISHED GPDW (NOT PTD. OR WITH WALLCOVERING) TO
BE TAPED AND SANDED.

1
A2-1
100 LEVEL PLAN
1/8" = 1'-0"
21. ALL PAINTED WALLS TO HAVE SATIN PAINT FINISH.
ALL PAINTED CEILINGS TO BE FLAT PAINT FINISH.

22. REFER TO CEILING PLANS FOR SPECIFIC CEILING LAYOUTS AND


HEIGHTS.

23. ALL EXT. STEEL TO BE GALVANIZED AND PTD. (U.N.O.).

24. UNLESS NOTED SPECIFICALLY ON DWGS ALL WOOD


BLOCKING, STEEL ANGLES, MISC. STEEL PLATES, ETC. ARE Holabird & Root, LLC expressly disclaims any
TO BE CONT. responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
25. GC TO COORD. WOOD BLOCKING FOR WALL-MOUNTED ITEMS writing.
SUCH AS MILLWORK, MARKERBOARDS, TOILET ACCESSORIES,
HANDRAILS, ETC. This drawing copy may have been reproduced at a size
JANITOR'S different than originally drawn. The Owner and Architect
CLOSET 26. GC TO COORD. WOOD BLOCKING FOR CEILING-MOUNTED ITEMS assume no responsibility for use of incorrect scale.
112 CHANGING
1'-8" SUCH AS PROJ. SCREENS, CURTAIN TRACK, ETC. Drawings are not to be scaled.
6'-5 1/2" 6'-6 1/4" 7'-1 3/4" 5'-4 1/2"
ROOM
113A
27. FOR LARGE OPENINGS IN FLOORS AND WALLS SEE STRUCT. Not published - All rights reserved.
DWGS. FOR CONCRETE & STRUCT INFILLS. FOR SMALL
A STAFF OPENINGS IN FLOOR SLABS, EITHER FILL WITH FIRESTOPPING

5'-1 1/2"
WOMENS MENS TOILET MATERIALS (SEE SPEC.) OR CONCRETE.
DIRECTOR STAFF

7'-7"
107 108 OFFICE TELECOM 113B
OFFICE 113
109 111 28. SEE ENLARGED PLANS AND SECTIONS FOR COORESPONDING
110
INFORMATION

29. SEE ID SHEETS FOR CORNER GUARDS.


3'-0" 2'-11" 3'-3"

5"
PAT. TOILET CORRIDOR CORRIDOR
6'-0"

100D 5'-9"
CONFERENCE 114 7" 5'-8" 100C
13'-0" 4'-11" SYMBOLS: FLOOR PLAN
102 CORRIDOR 10" 10"
100B SEE SHEET A1-1 FOR ADDITIONAL SYMBOLS AND ABBREVIATIONS
5'-0 1/2"

3'-0"
10"

7'-7" 2'-11 1/2" 1'-11 1/2"


B MED. PREP.
10'-4"

1'-0"
2'-9"

12'-0 1/2"
CLEAN
10"

115 SOILED NEW DOOR


4'-1"

1'-9" 2'-6" 2'-6" 2'-7" 12 STORAGE SUPPLY


10" 119
9'-5118
1/2"
1 09/07/2018 ISSUED FOR BID
1 2'-0" 10" EXISTING DOOR
3'-8" 4'-1 1/4" 3'-5"

2'-0" No. Date Issue


WATER
WAITING
11 TREATMENT NEW GLASS PARTITION
ROOM 2'-1" 8'-0" 2'-1" 10"
125
11'-0"

101 EXAM EQUIP.


NURSE

8'-7"
106 Project Number 15849
2 STATION REPAIR NEW PARTITION
1'-1 1/4"

120 Drawn S. DENNY


10" 10"
3'-7 1/2" 4'-6 1/4"

10 EXISTING PARTITION TO REMAIN Checked K. BOYER


LAB
7'-5 1/2"

C Proj. Arch./Eng. K. SCHUSTER

7'-7"
RECEPTION 3 121
10"

NOT IN SCOPE OF WORK (N.I.C.)


105 14'-11" 9'-5 1/2"
STORAGE
4'-5 1/2"

VESTIBULE 8'-0"
TREATMENT 2'-7" 122
9 CASEWORK / MILLWORK
5'-2"
100A AREA 5" 3'-9" 2'-9" 2'-9" 2'-10"
4 116 Provident Hospital - Renal
3'-2" 3'-1" 3'-0" 5"

D1.1 NON RATED PARTITION TYPE,


6 7 8
W.C. S
SEE PARTITION TYPES Dialysis Center
117A
11'-3"

SOCIAL PRIVATE D1.1 RATED PARTITION TYPE,


ELECTRICAL MECHANICAL
WORKER 5 PAT./ISOLATION S SEE PARTITION TYPES
123 124
104 117
10"

D KEYNOTES LEGEND
DIETITIAN 1'-3" 9'-6 1/2" 29'-10" 12'-1" 5'-8 1/2"
REF#
103 064116.02 PLASTIC LAMINATE LOCKER.
122413.01 MANUALLY OPERATED ROLLER SHADES
1 2 3 260000.01 DEVICE MOUNTED ON FURITURE. CONTRACTOR TO
COORDINATE WITH FURNITURE SUPPLIER TO CONCEAL 430 East 51st Place
ALL WIRING. Chicago, Illinois 60615

2
A2-1
100 LEVEL DIMENSION PLAN
1/8" = 1'-0"
Project Name

100 LEVEL FLOOR PLAN &


*SEE Q SERIES FOR OWNER
DIMENSION PLAN
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS Sheet Name

Drawing No. A2-1


GENERAL NOTES: ROOF PLAN
1. SHAFT WALLS TO BE 2-HR RATED.

2. COORDINATE ALL OPENINGS AND PENETRATIONS WITH


RELATED MECH. & STRUCT. DOCUMENTS. ROOFING AT
OPENINGS & PENETRATIONS TO BE INSTALLED PER
MANUFACTURER'S RECOMMENTATIONS.

3. INSULATION HEIGHT TO BE MIN. R-20.0 c.i. (PER ICC IECC 2009


ENERGY CODE) ON ROOF STRUCTURE (ROOF STRUCTURE TO
HAVE 1/4" PER 1'-0" SLOPE).

4. VERIFY TOP OF INSUL. & PARAPET IN FIELD.

5. ALL SPOT ELEVATIONS ARE TAKEN FROM THE ROOF LEVEL


(T.O. DECK AT LOW POINT).
Department of Capital Planning & Policy
Bureau of Asset Management
6. ALL TAPERED INSULATION FINAL SLOPE 1/4" MINIMUM.
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
7. EXISTING ROOFING TO REMAIN. PATCH AS REQUIRED FOR
for their confidential use only. In consideration of the loan
INSTALLATION OF NEW ROOF TOP EQUIPMENT. SEE MEP
of this drawing, the borrower promises and agrees to
DRAWINGS
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
SYMBOLS: ROOF PLAN directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

LOCATION OF EQUIPMENT CURB, COORDINATE


W/ MECH. DWGS

EXISTING ROOF TO REMAIN

ROOF CRICKETS, 1/2" / FT. TAPERED INS., TYP.

H.P. HIGH POINT


1 2 2 3
A4-2 L.P. LOW POINT

RIDGELINE (RL)

SLOPE 1/4" / FT, U.N.O.

A DS DOWNSPOUT

EXISTING
MECHANICAL
UNIT
EXISTING ROOF
HATCH TO REMAIN

A4-1 2
EXISTING SKYLIGHTS
TO REMAIN
1
A4-2

Holabird & Root, LLC expressly disclaims any


responsibility arising from any unauthorized use of these
C plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


EXISTING ROOFING, different than originally drawn. The Owner and Architect
DRAINS, EQUIPMENT assume no responsibility for use of incorrect scale.
TO REMAIN U.N.O. Drawings are not to be scaled.

Not published - All rights reserved.

A4-1

1
A2-3
ROOF PLAN
1/8" = 1'-0"
1 09/07/2018 ISSUED FOR BID
No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
26K7 Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center
L4x4x3/8

L4x4x3/8

430 East 51st Place


DECK OPENING DIMENSIONS Chicago, Illinois 60615
AND LOCATION ON ROOF TO
MATCH MEP DRAWINGS
Project Name

ROOF PLAN
26K7

2 TYP. FRAMING/JOIST FOR METAL DECK OPENING


Sheet Name

A2-3 N.T.S.
Drawing No. A2-3
GENERAL NOTES: REFLECTED CEILING PLANS
NOTES BELOW APPLY TO ALL CEILING PLANS:

1. CEILING GRID TO BE CENTERED IN ROOMS AS SHOWN, U.N.O.

2. DOWNLIGHTS TO BE CENTERED IN CEILING PANELS.

3. ALL GPDW CEILINGS & SOFFITS ARE 5/8" GPDW, U.N.O. - ALL
VERTICAL FACES OF SOFFITS ARE GPDW, U.N.O.

4. COORDINATE ALL MECH. DUCT WORK, PIPING, SPRINKLER


1 2 2 3 LINES & CABLE TRAY TO AVOID CONFLICTS WITH LIGHTS &
A4-2 STRUCTURE.

5. PROVIDE GPDW TRIMLESS ACCESS PANELS (2'-0" X 2'-0") FOR Department of Capital Planning & Policy
DIRECTOR JANITOR'S STAFF CHANGING GPDW CEILING AREAS. MINIMIZE NEED FOR ACCESS PANELS -
TELECOM STAFF
WOMENS MENS OFFICE OFFICE CLOSET TOILET ROOM COORD. LOCATION OF ACCESS PANELS WITH OTHER TRADES Bureau of Asset Management
FOR ITEMS ABOVE GPDW CEILING. Notice: This drawing has not been published and is the
A TYP
4 sole property of Cook County. It is loaned to the borrower
A9-1 6. SEE ELEC. DRAWINGS FOR SPECIFIC LIGHT FIXTURE TYPES, for their confidential use only. In consideration of the loan
N.C. 8' - 6" EXIT SIGNS, VISUAL ALARMS, ETC. of this drawing, the borrower promises and agrees to
8' - 6" return it upon request and agrees that it shall not be
8' - 0" 8' - 0" 7. SEE MECH. DRAWINGS FOR SPECIFIC MECH. DIFFUSERS. reproduced, copied, loaned, or otherwise disposed of
CORRIDOR
8' - 0" 8' - 0" 12' - 0" 12' - 0" 12' - 0" directly or indirectly, nor used for any purpose other than
SOILED
8. FOR CEILING HEIGHT CHANGES PROVIDE 5/8" GPDW FASCIA & for which it is furnished, in whole or part.
STORAGE
CONFERENCE SOFFIT (3 1/4" WIDE) U.N.O.
9' - 6" 9' - 6" 9' - 6" 12' - 0"
PAT. TOILET 7' - 6" 9. SEE MECH. DRAWINGS FOR SPECIFIC MECH. DIFFUSERS.
WINDOW POCKET
CLEAN WATER
MED. PREP. TREATMENT 10. SEE FIRE ALARM DRAWINGS FOR SPRINKLER DATA.
TYP SUPPLY
4
B A9-1 11. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER
8' - 0" 9' - 6" 9' - 6"
8' - 0" ENGINEERING DRAWINGS FOR LOCATION OF LIGHT FIXTURE
7' - 6" 8' - 6"
PLACEMENT.
6 Sim
A9-1 8' - 6" 1 N.C. 12. IN AREAS OF 2'x2' CEILING PANEL WHERE LESS THAN 4"
A9-1 WOULD BE REQUIRED TO FILL SPACE TO WALL, PROVIDE
8' - 6" 7' - 6" EQUIP. MATCHING 2'x4' PANEL & CUT DOWN TO TAKE UP 4" SPACE(DO
1 9' - 6" NURSE REPAIR NOT PROVIDE INTERVENING TEE GRID).
A4-2 STATION 7' - 6"
Sim
WAITING 1 9' - 6"
ROOM A9-1
10' - 0"
EXAM STORAGE LAB
C
9' - 6"
4 9' - 6" SYMBOLS: REFLECTED CEILING PLANS
A9-1 9' - 6"
8' - 0" 12' - 0"

9' - 6" 2'x2' ACOUSTICAL LAY-IN


PANELS
RECEPTION
8' - 6"
VESTIBULE TYP
4
A9-1 N.C. N.C. 2'x4' ACOUSTICAL LAY-IN
8' - 6" 12' - 0"
8' - 0" 12' - 0" PANELS
D
PRIVATE W.C. GYPSUM DRYWALL CEILING
SOCIAL TREATMENT ELECTRICAL MECHANICAL
DIETITIAN PAT./ISOLATION
WORKER AREA

N.C. OPEN TO STRUCTURE/ NO CEILING

LINEAR BOX LIGHT 2'X4'


1
A3-1
100 LEVEL REFLECTED CEILING PLAN
1/8" = 1'-0" LINEAR BOX LIGHT 2'X2'
Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
RECESSED COVE LIGHT W/ BAFFLE plans, drawings and notes. Any authorization must be in
LOUVER writing.
RECESSED DOWNLIGHT This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
48" LINEAR PENDANT (DIRECT/INDIRECT) assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
UNDER CABINET LIGHT FIXTURE
Not published - All rights reserved.

RECESSED VANITY COVE LIGHT

SUPPLY DIFFUSER

RETURN DIFFUSER

EXHAUST DIFFUSER

SPRINKLER HEAD

WALL MOUNTED SPRINKLER HEAD 1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

100 LEVEL REFLECTED CEILING


PLAN
Sheet Name

Drawing No. A3-1


GENERAL NOTES: BUILDING ELEVATIONS
2 THE NOTES BELOW APPLY TO A4 SERIES DRAWINGS ONLY:
A4-2
1. ?
MPX ?
BX ?
PCX NUMBER DESIGNATES MATERIALS OR FINISHES
1 2 3
2. ?
GX DESIGNATES GLASS TYPE. SEE PARTIAL ELEVATIONS FOR TARGETS.

3. GLASS TYPES NOT DESIGNATED ARE TO BE ?


G1

4. TEMPERED GLASS AT DOORS & OTHER AREAS PER BUILDING CODES.

T.O. STEEL 5. LOW "E" GLASS COLOR: CLEAR, SHADING COEFFICIENT IN SPEC. SECTION
+17' - 0" 08810.

6. REFER TO A7-2 FOR FRAME TYPES & DIMENSIONS.


Department of Capital Planning & Policy
7. REFER TO SPEC. SECTION 08810 TO MATCH GLASS APPEARANCE. Bureau of Asset Management
8. HEAT TREATED WHERE REQUIRED, BOTH LITES. Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
9. EXISTING BUILDING WALL: 4" CMU ON 8" CMU BACKUP WITH 2" RIGID for their confidential use only. In consideration of the loan
INSULATION BOARD of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
10. EXISTING STOREFRONT: 2 x 4.5" THERMALLY BROKEN ALUMINUM FRAMES reproduced, copied, loaned, or otherwise disposed of
WITH KYNAR FINISH V.I.F. directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

100 LEVEL KEYNOTES LEGEND


+0' - 0" REF#
NEW HM FIXED DOOR PANEL
EXISTING UTILITIES NEW DOOR OPENING. CUT
IN EXISTING FRAME
TO REMAIN INTO EXISTING MASONRY
WALL.

1
A4-1
SOUTH ELEVATION
3/16" = 1'-0" [REF: 1/ A2-1]

Level 5
A B 1 C D 4 +9' - 8"
A4-2 NEW STOREFRONT
A4-1
TO MATCH EXISTING

SEE DETAIL 8/A9-1 4


A4-1 NEW 2" STONE SILL TO
MATCH EXISTING
G1
NEW STOREFRONT
NEW STOREFRONT
INFILL

V.I.F.
6'-8"
6' - 8"
5 5
A4-1 A4-1 4" CMU, GROUTED SOLID AND
(E) GLASS & ALUM.
DOWELED INTO ADJACENT CMU
STOREFRONT TO
REMAIN NEW CAST STONE,
2" STONE SILL TO 2" RIGGED INSULATION
MATCH EXISTING
MATCH EXISTING. CAST STONE, MATCH EXISTING 3
2"
GBDW ON FURRING A4-1

2"
CHANNEL

V.I.F.
100 LEVEL CAST STONE

1'-4"
1' - 4"
+0' - 0" PLINTH TO REMAIN
EXISTING CARD 100 LEVEL 100 LEVEL
3 Sim READER POST. +0' - 0"
+0' - 0"
A4-1 PREP AND REPAINT.

NEW CAST STONE


NEW STOREFRONT TO MATCH EXISTING
ENTRANCE DOOR IN
Holabird & Root, LLC expressly disclaims any
EXISTING FRAME
responsibility arising from any unauthorized use of these
2
A4-1
WEST ELEVATION
3/16" = 1'-0" [REF: 1/ A2-1]
3
A4-1
EXTERIOR ENTRANCE INFILL
1/2" = 1'-0" [REF: 2/ A4-1]
4
A4-1
NEW STOREFRONT SECTION
1/2" = 1'-0" [REF: 3/ A4-1]
5
A4-1
NEW STOREFRONT PLAN DETAIL
1/2" = 1'-0"
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.

EXISTING
CONCRETE
PAVING

1 09/07/2018 ISSUED FOR BID


ALIGN

No. Date Issue

EXISTING
RETAINING Project Number 15849
WALL
Drawn S. DENNY
EXISTING
ALIGN

FENCE Over all Out to Out 2. Checked K. BOYER


Ameristar Standard 6"
2" (Hinge Clearance) 3" (Latch Clearance) 2" (Hinge Clearance) Proj. Arch./Eng. K. SCHUSTER
Leaf Widths 2
3'-0"

EXISTING TM
11/2" MONTAGE PLUS Rail
BOLLARD 4" (See Cross- Section on Panel Drawing)
NEW GENERATOR. SEE Post size varies with Height
(See MONTAGE PLUS TM Post-Sizing chart)
ELECTRICAL DRAWINGS 4
Varies 1
with Gate Upright
13/4" x 14 ga.
Provident Hospital - Renal
Height
Dialysis Center
14'-0"
8'-0"

4' - 0"
7' - 4"
NEW WROUGHT 3/ "
4 x 18ga. Picket
GATE IRON FENCING. SST BASE PLATE WITH
COVER
SEE DETAIL 7/A4-1
STEEL COLUMN
Weld on Box Hinge CIP FOOTER
3'-0"

± 8'-8" 3 STEEL PLATE CROSS


2"
Nom. SUPPORT
NEW CONCRETE S.O.G. 315/16" TYP.
1'-6"

ALIGN TOP OF SLAB 36" Min.


W/EXISTING CURB Footing depth
6'-0" 430 East 51st Place

2' - 0"
NEW BOLLARDS. Chicago, Illinois 60615

2' - 6"
SEE DETAIL 8/A4-1
Double gate Arrangement Values shown are nominal and not to be used
NOTES:
for installation purposes. See product Project Name
1.) Post size depends on fence height, weight and wind loads. specification for installation requirements.

EXISTING LANDSCAPE See MONTAGE PLUS TM post sizing chart.


2.) See Ameristar gate table for standard out to outs. Custom gate
openings available for special out to out/leaf widths.
BUILDING ELEVATIONS
3.) Additional styles of gate hardware are available on request.
This could change the Latch & Hinge Clearance. 1' - 6"

6 GENERATOR ENCLOSURE 7 WROUGHT IRON GATE 8 SECTION DETAIL - CONCRETE BOLLARD AT DOORS
Sheet Name

A4-1 1/4" = 1'-0" A4-1 1/2" = 1'-0" ? A4-1 3/4" = 1'-0" ?


Drawing No. A4-1
1 2 3
2
A4-2

Department of Capital Planning & Policy


Bureau of Asset Management
T.O. STEEL
+17' - 0" Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
024119.15 return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

100 LEVEL
+0' - 0"

1
A4-2
NORTH SOUTH SECTION
3/16" = 1'-0" [REF: 1/ A2-1]
1
A4-2

A B C D

T.O. STEEL
+17' - 0"

100 LEVEL
+0' - 0" Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
2
A4-2
EAST WEST SECTION
3/16" = 1'-0" [REF: 1/ A2-1]
Drawings are not to be scaled.

Not published - All rights reserved.

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


KEYNOTES LEGEND Dialysis Center
REF#
024119.15 NEW DUCT WORK OPENINGS IN CMU BULKHEAD. SEE
MECHANICAL DRAWINGS. USE EXISTING OPENINGS WHERE
POSSIBLE. PROVIDE NEW LINTELS WHERE NECESSARY.

430 East 51st Place


Chicago, Illinois 60615

Project Name

BUILDING SECTIONS

Sheet Name

Drawing No. A4-2


SEE PLAN

4' - 8" CLEAR MIN.

4' - 6" MIN. SENSOR ABV GRAB BAR


(PLUMBING CONTR TO
EXPOSED FLUSH VALVE W/ 3' - 0" (36")
1' - 0" 3' - 6" (42") COORDINATE)

1' - 6"
SENSOR (SEE PLUMBING 102800.03 1' - 0"
DWG.) IF NO SENSOR HANDLE 102800.03
102800.04

1' - 6" (18")

5' - 0" CLEAR MIN.


ON OPEN W.C. SIDE. min
3' - 4" EXPOSED FLUSH
224000.02
VALVE (SEE PLUMB. 1' - 8" 8"

3' - 6" MIN.


DWGS.)
224000.02
224000.02

2' - 11 1/2" T/

2' - 11 1/2" T/
224000.01 224000.02 102800.04

2' - 10 3/4"

2' - 10 3/4"
3' - 4"

3' - 2"

2' - 3 1/2"

2' - 7"

2' - 4"
1' - 5"

1' - 5"
1' - 3"

Department of Capital Planning & Policy


TOILET - TYPICAL & ACCESSIBLE TOILET - ACCESSIBLE TOILET - ACCESSIBLE TOILET - TYPICAL TOILET - ACCESSIBLE Bureau of Asset Management
A B C D E
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
2" 2" 2"
for their confidential use only. In consideration of the loan
102800.06 102800.06 of this drawing, the borrower promises and agrees to
1' - 0"
102800.08 102800.08 return it upon request and agrees that it shall not be
102800.08
102800.09
reproduced, copied, loaned, or otherwise disposed of
102800.09 102800.09 directly or indirectly, nor used for any purpose other than
102800.10 102800.10 for which it is furnished, in whole or part.
TO REFLECTIVE SURFACE

TO REFLECTIVE SURFACE

224000.03 224000.03 224000.03

TO HANDLE

TO HANDLE

TO WORK SURFACE
4' - 0" MAX

4' - 0" MAX


3' - 10"

3' - 10"

3' - 10"

2' - 10" MAX


3' - 4"

3' - 4"

2' - 7" MAX


2' - 10"

2' - 10"

1' - 3" MIN. IF ADJACENT

CLEAR
TO WALL, U.N.O.

LAVATORY, MIRROR, & ACCESSORIES LAVATORY, MIRROR, & ACCESSORIES LAVATORY, MIRROR, & ACCESSORIES BABY CHANGING STATION BABY CHANGING STATION
F G ADJACENT TO WALL - FRONT VIEW
H ADJACENT TO WALL - SIDE VIEW
I J

1
A6-1
TOILET ROOM ELEVATIONS, PLANS, ACCESSORIES AND MISC.
N.T.S.

AUDIO/VISUAL ALARM CENTERED


ABOVE FIRE ALARM PULL
RECESSED FIRE EXTINGUISHER CABINET W/
SIGNAGE, U.N.O 1/2" PROJECTING FRAME & WHITE FINISH.
(VERTICAL RED DIE-CUT LETTERING FOR "FIRE
FIRE ALARM PULL EXTINGUISHER")

COORDINATE DOOR SWING @ CABINET


COAT HOOK, DOOR FOR DOOR TO SWING AGAINST
MOUNTED
ADJACENT WALL
DOOR IS 4" AWAY FROM ADJACENT
WALL FOR 90-DEGREE PER ACC 6" TO AT 34" ACCESSIBLE TOP - 46"
TO CL OF ELEC. OUTLET
C
L 8" 8" TO TYP.
1' - 1"
AT 36" NON-ACCESSIBLE TOP - 46"
DOOR OPENING IS 18" (MIN) FOR TO CL OF ELEC. OUTLET
OF ALARM (ACC)

FRONT APPROACH PER ACC


4"

TO HIGHEST OPERABLE HEIGHT


1' - 6"

2' - 4"

1' - 0"
(ACC)

10"
8"
3' - 10" (ACC) MAX.

4' - 7 1/4"
5' - 0"
4' - 0" (ADA)

3' - 10" (46")


6' - 8" TO

4' - 10" TO

4' - 0"
3' - 10"

2' - 10" (34")

3' - 0"
2' - 3 1/4"

1' - 6"
1' - 0"
NOTE FOR SWITCHES: ELECTRIC LIGHT SWITCH CABINET W/ FIRE EXTINGUISHER
ALL SWITCHES MUST BE DESIGNED FOR THERMOSTAT ELECTRICAL OUTLET (MOUNT
WHEELCHAIR FRONT REACH (2010 ADA). WALL PHONE TO ALIGN VERTICAL U.N.O. ON ELEC. DWG.)
DOOR OPENING IS 12" (MIN) FOR FRONT W/ TOP OF LIGHT SWITCH
APPROACH IF CLOSER & LATCH PER ACC 34" ACCESSIBLE TOP W/ 4" BACKSPLASH Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
2
A6-1
CLEARANCE PLAN AT DOORWAYS, TYP.
N.T.S.
3
A6-1
ELEVATION - ACCESSIBLE MOUNTING HEIGHTS
N.T.S.
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
1' - 10" DOOR FRAME
NURSE TERMINAL Not published - All rights reserved.
LIGHT SWITCH 6" TYP.
DOOR FRAME LENGTH
THERMOSTAT CH-4
LIGHT SWITCH SEE ELEVATIONS
EQ EQ WALL PHONE CH-1
HAND SANITIZER HAND SANITIZER

48" ACCESSIBLE
84"

60"
48" MAX

50 1/2"
47 3/4"

47 3/4"

54"
48"
48"

CONFIRM W/
46"

46"

46"

46"

46"

ARCHITECT
15" MIN

8" 8" 9"

6" UNO 6 1/4" 6" UNO


GENERAL REACH RANGE FOR APRON RACK CLOCK DATA & ELEC IN ALCOVE ACCESSORIES ACCESSORIES NURSE CALL DEVICE THERMOSTAT COAT HOOKS (CH-X) COAT HOOK, ACCESSIBLE (CH-X) DIAGNOSTIC INSTRUMENT EQUIPMENT RAIL WALL MOUNTED
MIN AND MAX HEIGHTS, U.N.O. ADJACENT TO DOOR ADJACENT TO DOOR (TOILET ROOMS) PANEL (DISE-01) COMPUTER MONITOR, NIC 1 09/07/2018 ISSUED FOR BID
BRACKET
No. Date Issue

Project Number 15849


Drawn S. DENNY
TO HIGHEST OPERABLE HEIGHT

TO HIGHEST OPERABLE HEIGHT

Checked K. BOYER
22"

Proj. Arch./Eng. K. SCHUSTER


69 1/2"

57 3/4"

45 1/2"
48"

48"
44"

44"

44"

44"

44"
34"

34"

34"

34"
32"
30"

Provident Hospital - Renal


14"
Dialysis Center
AED DEVICE GLOVE BOX HOLDER GLOVE BOX HOLDER, ABOVE HAND SANITIZER, WALL MARKER/TACKABLE SURFACE, MOP RACK SPECIMEN SHARPS CONTAINER SHARPS CONTAINER, ABOVE TELEVISION PAPER TOWEL DISPENSER, ABOVE CHAIR RAIL
KEYNOTES LEGEND
COUNTER MOUNTED ABOVE COUNTER PASS THROUGH COUNTER COUNTER & IN TOILET ROOMS REF#
102800.03 GRAB BAR (42") AND VERTICAL GRAB BAR (18")
102800.04 GRAB BAR (36")

4
A6-1
TYPICAL EQUIPMENT MOUNTING HEIGHTS
N.T.S.
102800.06
102800.08
MIRROR - ABOVE COUNTERTOP (SURFACE MOUNTED)
PAPER TOWEL DISPENSER
102800.09 SOAP DISPENSER
102800.10 BABY CHANGING TABLE
224000.01 WATER CLOSET
430 East 51st Place
224000.02 WATER CLOSET - ACCESSIBLE Chicago, Illinois 60615
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ PIPE
COVER
Project Name

TYPICAL PLANS, ELEVATIONS, &


DETAILS
Sheet Name

Drawing No. A6-1


224000.03
102800.13

PAT. TOILET
114 102800.06
4
102800.09
102800.09 102800.03 102800.06
7 A6-2 5 102800.09

5' - 11"
102800.03
102800.04 102800.04
224000.02 6 102800.09
102800.13 224000.03
B NURSE CALL
102800.03
224000.03
102800.03
Department of Capital Planning & Policy
102800.04 224000.03
BUTTON
102800.03
Bureau of Asset Management

1' - 6"
224000.02 224000.02 224000.02
TILE COVE Notice: This drawing has not been published and is the
TILE COVE TILE COVE sole property of Cook County. It is loaned to the borrower
BASE, TYP. BASE, TYP.
BASE, TYP. for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
PBT1 PWT1 PBT1 PWT1 PBT1 reproduced, copied, loaned, or otherwise disposed of
7' - 2" directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

1
A6-2
114_PATIENT TOILET
1/2" = 1'-0"
4
A6-2
PATIENT TOILET - WEST
3/8" = 1'-0" [REF: 1/ A6-2]
5
A6-2
PATIENT TOILET - NORTH
3/8" = 1'-0" [REF: 1/ A6-2]
6
A6-2
PATIENT TOILET - EAST
3/8" = 1'-0" [REF: 1/ A6-2]
7
A6-2
PATIENT TOILET - SOUTH
3/8" = 1'-0" [REF: 1/ A6-2]
8
A6-2
WATER CLOSET - NORTH
3/8" = 1'-0" [REF: 2/ A6-2]

5' - 3 1/2"

NURSE CALL
102800.08
BUTTON
W.C. 102800.09
117A 102800.03
224000.03
11 102800.10
224000.03
10 A6-2 8 224000.02
TILE COVE
9 TILE COVE TILE COVE
9' - 2 1/2"

BASE, TYP.
BASE, TYP. BASE, TYP.
224000.03

102800.09
PBT1 PBT1
224000.02

9
A6-2
WATER CLOSET - EAST
3/8" = 1'-0" [REF: 2/ A6-2]
10 WATER CLOSET - SOUTH
A6-2 3/8" = 1'-0" [REF: 2/ A6-2]
11 WATER CLOSET - WEST
A6-2 3/8" = 1'-0" [REF: 2/ A6-2]
12 STAFF TOILET - NORTH
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
13 STAFF TOILET - EAST
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
1' - 6"

102800.04

102800.03

102800.03
102800.06
NURSE CALL 102800.10
102800.09
BUTTON
102800.08 102800.04
224000.03 102800.03 102800.09
102800.04

2
A6-2
117A_WATER CLOSET
1/2" = 1'-0" PWT1
224000.02

TILE COVE
224000.02 Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
BASE, TYP. writing.
PBT1
This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
102800.10 Drawings are not to be scaled.
224000.02
102800.03
REMOVE 6"X6" TILE
ON EXISTING WALL 14 STAFF TOILET - SOUTH
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
15 STAFF TOILET - WEST
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
Not published - All rights reserved.

A
1' - 6"

15
5' - 6"

14 A6-2 12
102800.04

102800.09 13 STAFF
TOILET
113B

224000.03
1 09/07/2018 ISSUED FOR BID
102800.08
No. Date Issue

8' - 9 3/4" Project Number 15849


Drawn S. DENNY

3
A6-2
113B_STAFF TOILET
1/2" = 1'-0"
Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

KEYNOTES LEGEND
REF#
102800.03 GRAB BAR (42") AND VERTICAL GRAB BAR (18")
102800.04 GRAB BAR (36")
102800.06 MIRROR - ABOVE COUNTERTOP (SURFACE MOUNTED)
102800.08 PAPER TOWEL DISPENSER
430 East 51st Place
102800.09 SOAP DISPENSER Chicago, Illinois 60615
102800.10 BABY CHANGING TABLE
102800.13 SEMI-RECESSED PAPER TOWEL DISPENSER & WASTE
RECEPTACLE; 12-GAL WASTE CONTAINER. Project Name
224000.02 WATER CLOSET - ACCESSIBLE
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ PIPE TOILET ROOMS
COVER

Sheet Name

Drawing No. A6-2


ALL 4-7/8" PARTITIONS ARE PARTITION LEGEND
DIMENSIONED 5" ON
PLANS FIRE-RATED PARTITION
4 7/8" 6 1/8" 7 1/4" 4 1/4" PARTITION TYPE PARTITION TYPE
5/8" 3 5/8" 5/8" 5/8" 3 5/8" 5/8" 5/8" 6" 5/8" 3 5/8" 5/8" 3 5/8" METAL STUD (U.N.O.) D1.1 D1.1
3 5/8" METAL STUD (U.N.O.) 3 5/8" METAL STUD (U.N.O.) 3 5/8" METAL STUD (U.N.O.) S S
EXTENT OF GPDW
EXTENT OF GPDW
5/8" 5/8" 5/8" GPDW (U.N.O.)
5/8" GPDW (U.N.O.) 5/8" GPDW (U.N.O.)
5/8" TYPE "X" GPDW (USG
5/8" TYPE "X" GPDW (USG 2 LAYERS 5/8" GPDW (U.N.O.) 5/8" TYPE "X" GPDW (USG TYP. FIRE RATED PARTITION TYP. NON-RATED PARTITION
FIRECODE 'C') @ RATED
FIRECODE 'C') @ RATED 5/8" TYPE "X" GPDW (USG FIRECODE 'C') @ RATED
WALLS
WALLS FIRECODE 'C') @ RATED WALLS WALLS
1 1/2" SOUND EXTENT OF GPDW
1 1/2" SOUND 1 1/2" SOUND 1 1/2" SOUND
ATTENUATION ATTENUATION ATTENUATION
ATTENUATION X = HEIGHT OF STUDS/CMU & GPDW
BLANKET AT BLANKET AT BLANKET AT
BLANKET AT s
s s s 1 STUDS/CMU TO UNDERSIDE OF SLAB, GPDW TO SLAB

2 STUDS/CMU TO SLAB, GPDW TO 4" ABOVE CEILING


Department of Capital Planning & Policy
Bureau of Asset Management
3 STUDS/CMU TO CEILING, GPDW TO CEILING Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
D1.X 3 5/8" METAL STUD D2.X 3 5/8" METAL STUD D5.X 6" METAL STUD D40.X 3 5/8" METAL STUDS 4 LOW WALL, SEE A2-1 THRU A2-2 FOR HEIGHT for their confidential use only. In consideration of the loan
(40 STC) AT s (55 STC) AT s (40 STC) AT s (40 STC) AT s of this drawing, the borrower promises and agrees to
(UL DES U419 @ 1-HR RATED WALLS) (UL DES U419 @ 2-HR RATED WALLS) (UL DES U419 @ 1-HR RATED WALLS) (UL DES U419 @ 1-HR RATED WALLS) CLASSIFICATION FOR GPDW PARTITIONS return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
D1 THRU D39 STANDARD PARTITION TYPES directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.
DRYWALL PARTITIONS D40 THRU D59 CHASE WALLS

D60 THRU D79 SPECIAL CONDITIONS


7 1/8" 8 5/8" SEE PLANS
F1 THRU F9 FURRING WALL
5 5/8" 5 5/8" 1 1/2" 1 1/2" 5 5/8" 1 1/2" 5 5/8" 2 1/2" METAL STUD W/ 2 7 5/8"
1/2" STUD CROSS S1 THRU S25 SHAFT WALLS
BRACING @ 24" O.C.
GENERAL NOTES: PARTITION TYPES
5/8" GPDW
CMU (16" LONG X 8" HIGH 7/8" METAL FURRING CHANNEL 7/8" METAL FURRING CHANNEL CMU (16" LONG X 8" HIGH 1. SEE PARTITION TYPES FOR STUD DEPTHS. SEE PARTITION SCHEDULE FOR STUD
MODULAR BLOCK) 2-HR RATED WITH SHIM AS REQUIRED WITH SHIM AS REQUIRED CMU (16" LONG X 8" MODULAR BLOCK) 2-HR RATED GAUGE & STUD SPACING.
HIGH MODULAR BLOCK)
5/8" GPDW 5/8" GPDW 2-HR RATED 2. SEE PLANS FOR PARTITION TYPES. ALL NEW PARTITIONS ON PLAN TO BE TYPE D1.1
S
UNLESS NOTED OTHERWISE.
CMU (16" LONG X 8" HIGH CMU (16" LONG X 8" HIGH
MODULAR BLOCK) 2-HR RATED MODULAR BLOCK) 2-HR RATED
3. ALL CERAMIC TILE ON THE WALL IS THIN SET (APPROXIMATE 3/8" THICK). THE
DIMENSION OF THE WALL PARTITION THICKNESS ON THE PLANS DO NOT INCLUDE
THE 3/8" THICKNESS.

4. PARTITIONS ENCLOSING SPACES WITHOUT CEILINGS ARE TO EXTEND TO UNDERSIDE


OF DECK ABOVE.
C11.X 6" CMU C12.X 6" CMU C13.X 6" CMU C14.X 6" CMU C21.X 8" CMU
(UL DES U906 @ 2-HR RATED WALLS) (UL DES U906 @ 2-HR RATED WALLS) (UL DES U906 @ 2-HR RATED WALLS) (UL DES U906 @ 2-HR RATED WALLS) (UL DES U @ 3-HR RATED WALLS) 5. ALL FIRE RATED PARTITION ASSEMBLIES ARE TO BE CARRIED TO THE SLABABOVE &
VOIDS FILLED AT TOP.

CMU OR CMU SUBSTRATE FOR PARTITIONS 6. ALL VOIDS THROUGH & AT THE PERIMETER OF FIRE RATED PARTITIONS ARE TO BE
FILLED WITH FIRE STOPPING PRODUCTS.

7. ALL GPDW PARTITIONS, SOFFITS, FASCIAS, ETC. ARE TO HAVE METAL DRYWALL TRIM &
1 1/2" METAL CORNER BEAD (NO PLASTIC TRIM).

8. INSTALL A CONTROL JOINT SYSTEM @ 30'-0" MAX. FOR GPDW PARTITIONS.


5/8" GPDW TO 4" ABOVE CEILING
9. ALL GPDW PARTITIONS:
A. ALL FIRE RATED PARTITIONS AND PARTITIONS WITH SOUND ATTENUATION TO BE
7/8" METAL FURRING CHANNEL
CAULKED @ PERIMETER.
WITH SHIM AS REQUIRED
B. NON-RATED METAL STUD PARTITIONS ARE TO HAVE STUDS EXTENDED TO
VAPOR RETARDER, ADHERE STRUCTURE ABOVE (U.N.O).
TO CMU @ TOP & BOTTOM C. ALL GPDW PARITIONS IN TOILETS, PANTRY AREAS, KITCHENS, & JANITOR'S
CLOSETS TO EXTEND TO THE STURCTURE ABOVE.
EXISTING WALL D. FOR TYPICAL SHAFTWALL PARTITIONS THE 1" LINER PANEL IS TO BE EXPOSED TO
THE SHAFT SIDE & OTHER GPDW TO BE EXPOSED TO THE ROOM SIDE.
E. USE WATER RESISTANT GPDW ON ALL PARTITIONS WHICH ARE PENETRATED BY
PLUMBING PIPING. Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
10. ALL CMU OR BLOCK PARTITIONS: plans, drawings and notes. Any authorization must be in
A. ALL FIRE RATED PARTITIONS AND PARTITIONS WITH SOUND ATTENUATION TO BE writing.
CAULKED @ PERIMETER.
F9.X EXISTING WALL B. FIRE RATED UNITS SHALL COMPLY W/ THE STANDARDS OF AMERICAN This drawing copy may have been reproduced at a size
INSURANCEASSOCIATION AND SHALL HAVE AN EQUILVALENT THICKNESS IN different than originally drawn. The Owner and Architect
EXCESS ON MIN. REQUIREMENTS. (COORDINATE PARTITION TYPE W/ RATING assume no responsibility for use of incorrect scale.
FURRING WALL PARTITIONS SYMBOLS ON PLANS).
C. 5" HIGH X 16" STARTER COURSE TO BE PROVIDED AT PARTITIONS W/ 7'-0" HIGH
Drawings are not to be scaled.

DOOR FRAMES Not published - All rights reserved.


FIRE RATED GPDW PARTITION, SEE FIRE -RATED GPDW PARTITION ,
PLANS FOR PARTITION TYPES SEE PLANS FOR PARTITION TYPES
D. CMU PARTITIONS NOT EXTENDED TO SLAB ABOVE TO BE LATERALLY BRACED W.
FIRE-RATED GPDW PARTITION, METAL STUD KICKERS AT TOP OF THE PARTITION, U.N.O. COORDINATE
SEE PLANS FOR PARTITION TYPES 1/4" FIRE BARRIER WRAP STRIP W/ HVAC & OTHER TRADES.
PIPE OR CONDUIT TO BE CENTERED FIRE-RATED GPDW PARTITION, SEE
WITHIN THE FIRESTOP SYSTEM AND RIGIDLY PIPE COVERING PLANS FOR PARTITION TYPES
CABLE OR CABLE BUNDLE 1"O.D. MAX.
SUPPORTED ON BOTH SIDES RIGIDLY SUPPORTED ON BOTH SIDES 1/2" 11. PROVIDE FIBERGLASS FACED GPDW AT ALL WET WALLS.
ONE METALLIC PIPE OR TUBING TO MINERAL WOOL BATT PACKING, 1" MIN.
BE CENTERED WITHIN THE FIRESTOP
SYSTEM AND RIGIDLY SUPPORTED ON BOTH STEEL SLEEVE
SIDES FIRE BARRIER CAULK, 1" MIN. STEEL STUD SCHEDULE - INTERIOR PARTITIONS & USES
6" MAX.

CABLE BUNDLE ALLOW. MAXIMUM STUD HEIGHT


CAULK FILL MATERIAL TO STUD TYPE & DATA GPDW LAYERS
COMPLETELY FILL ANNULAR APACE BETWEEN CAULK FILL MATERIAL TO COMPLETELY DEFLECT. 2 1/2" 3 5/8" 4" 6"
FILL ANNULAR SPACE BETWEEN PIPE 1/4" CONT. BEAD OF FIRE CAULK 1/4" CONT. BEAD OF FIRE CAULK
PIPE AND GPDW, 1/4" CONT. BEAD OF FIRE CAULK
AND GPDW, 1/4" CONT. BEAD OF FIRE CAULK RIBBED [DIETRCH DATA] (1) 5/8" EACH SIDE L/240 11'-10" 15'-4" 16'-9" 21'-10"
GAUGE: 25 (0.0155")
(1) 5/8" EACH SIDE L/360 10'-4" 13'-1" 14'-7" 19'-1"
SINGLE PIPE/CONDUIT THROUGH SINGLE INSULATED PIPE THROUGH SINGLE INSULATED PIPE THROUGH CABLE BUNDLE THROUGH STUD SPACING 16" O.C.
AIR PRESSURE: 5 PSF (2) 5/8" EACH SIDE L/240 15'-1" 17'-0" 15'-9" 23'-8"
GYPSUM WALLBOARD ASSEMBLY GYPSUM WALLBOARD ASSEMBLY GYPSUM WALLBOARD ASSEMBLY GYPSUM WALLBOARD ASSEMBLY
(UL SYSTEM #W-L-1001) (UL SYSTEM #W-L-3001) (UL SYSTEM #W-L-5001) (UL SYSTEM #W-L-3032) (2) 5/8" EACH SIDE L/360 13'-2" 14'-0" 16'-7" 20'-8"
1, 2, 3 & 4 HR RATING FIRE-RATED FLOOR OR WALL 1 & 2 HR RATING 1 & 2 HR RATING 1 & 2 HR RATING
1 09/07/2018 ISSUED FOR BID
ASSEMBLY, 3 1/4" MIN. CONCRETE NON-RIBBED [USG DATA] (1) 5/8" EACH SIDE L/240 12'-6" 16'-0" 17'-3" 20'-0" No. Date Issue
OR UL CLASSIFIED CMU FIRE-RATED FLOOR OR WALL GAUGE: (0.0188")
ASSEMBLY, 2 1/2" MIN. CONCRETE CABLE BUNDLE, RIGIDLY STEEL DUCT, RIGIDLY
STUD SPACING: 16" O.C. (1) 5/8" EACH SIDE L/360 10'-9" 14'-0" 15'-0" 20'-0"
OR UL CLASSIFIED CMU SUPPORTED ON BOTH SIDES SUPPORTED ON BOTH SIDES
PIPE OR CONDUIT TO BE CENTERED AIR PRESSURE: 5 PSF (2) 5/8" EACH SIDE L/240 13'-6" 16'-9" 17'-3" 20'-0"
WITHIN THE FIRESTOP SYSTEM AND PIPE COVERING FIRE-RATED FLOOR OR WALL FIRE-RATED FLOOR OR WALL Project Number 15849
6 1/4" MAX.
RIGIDLY SUPPORTED ON BOTH SIDES ASSEMBLY, 4 1/2" MIN. CONCRETE ASSEMBLY, 4 1/2" MIN. CONCRETE
ONE METALLIC PIPE OR TUBING OR UL CLASSIFIED CMU OR UL CLASSIFIED CMU
(2) 5/8" EACH SIDE L/360 11'-9" 14'-9" 15'-9" 20'-0"
TO BE CENTERED WITHIN THE Drawn S. DENNY
CHASE WALL [USG DATA] (1) 5/8" EACH SIDE L/240 13'-3" 17'-6" 22'-9"
1'-6" MAX.

FIRESTOP SYSTEM AND RIGIDLY


6" MAX.

SUPPORTED ON BOTH SIDES GAUGE: 25 (0.0188") Checked K. BOYER


(1) 5/8" EACH SIDE L/360 11'-6" 15'-6" 19'-9"
STUD SPACING: 16" O.C.
Proj. Arch./Eng. K. SCHUSTER
AIR PRESSURE: 5 PSF (2) 5/8" EACH SIDE L/240 14'-6" 19'-0" 23'-6"
FIRE BARRIER CAULK, 1" MIN. FIRE BARRIER CAULK, 1" MIN.
PUTTY, 3 1/4" MIN. THICKNESS OF MINERAL WOOL BATT PACKING, 1" MIN. MINERAL WOOL BATT PACKING, (2) 5/8" EACH SIDE L/360 12'-9" 16'-6" 21'-3"
FILL MATERIAL FLUSH WITH BOTH FIRE BARRIER CAULK, 1" MIN. 1" MIN.
FACES OF WALL/FLOOR MINERAL WOOL BATT PACKING, 1" MIN. 1/2" C-H 4" C-H 6" C-H DBL. 6"
STUD STUD STUD E STUD
SINGLE INSULATED PIPE THROUGH SINGLE INSULATED PIPE THROUGH CABLE BUNDLE THROUGH STEEL DUCT THROUGH SHAFT WALL [USG DATA] 1" SHAFT + (2) 5/8" L/240 10'-5" 13'-10" 23'-11" 26'-3"
Provident Hospital - Renal
CONCRETE OR CMU WALL/FLOOR CONCRETE OR CMU WALL/FLOOR CONCRETE WALL/FLOOR CONCRETE OR CMU WALL/FLOOR
GAUGE: 25 (0.0188") OTHER SIDE Dialysis Center
(UL SYSTEM #C-AJ-1041) (UL SYSTEM #C-AJ-5001) (UL SYSTEM #C-AJ-3021) (UL SYSTEM #C-AJ-7003)
STUD SPACING: 16" O.C.
1 & 2 HR RATING 1 1/2, 2 & 3 HR RATING 2 HR RATING 3 HR RATING
3-5/8" RUNNER METAL AIR PRESSURE: 5 PSF 1" SHAFT + (2) 5/8" L/240 9'-3" 12'-6" 19'-2" 23'-0"
ROOF CONSTRUCTION 3-5/8" METAL STUD, TRACK OTHER SIDE
ROOF CONSTRUCTION U.N.O.
ROOF CONSTRUCTION ROOF CONSTRUCTION EXISTING STRUCTURAL MEMBER EXISTING STRUCTURAL MEMBER CEILING SUSPENSION
UL RATED 4 PCF DENSITY MINERAL UL RATED 4 PCF DENSITY MINERAL SPRAY-APPLIED FIRE RESISTIVE MATERIAL 14 GA. MISC. STEEL PLATE; MIN 1 1/2" TIE-ROD TO UNDERSIDE THE NOTES BELOW APPLY TO PARTITION SCHEDULE ABOVE.
OVERLAP OF SUPPORT GRID, TYP.
WOOL BATT INSULATION PACKED INTO WOOL BATT INSULATION PACKED INTO AFTER INSTALLATION OF METAL STUD 1. ALL GPDW PARTITIONS ARE BASED ON "DIETRCH" OR "USG" DATA. OTHER
FLUTE VOID FLUTE VOID RUNNER TRACK. FILL THE ENTIRE FLUE VOID SPRAY-APPLIED FIRE RESISTIVE MATERIAL
AFTER INSTALLATION OF METAL STUD RUNNER
MANUFACTURERS TO MEET OR EXCEED PARTITION PERFORMANCE LISTED ABOVE.
UL RATED CAVITY MATERIAL; MIN 1/2". AT TOP OF STEEL BEAM,
METAL STUD RUNNER TRACK; SECURED TO TRACK. FILL THE ENTIRE FLUE VOID AT TOP OF 2. FOR HEIGHTS OVER MAX. HEIGHTS LISTED USE KICKERS TO STRUCTURE ABOVE.
THE BOTTOM OF STEEL FLANGE THRU STEEL BEAM, (COORDINATE W/ HVAC & OTHER TRADES).
25 GA. RESTRAINING ANGLES 25 GA. RESTRAINING ANGLES
MIN.

SPRAY FIRE RESISTIVE MATERIAL METAL STUD RUNNER TRACK; SECURED 3. USE L/360 ALLOWABLE DEFLECTION FOR "TILED" WALLS.
6"

MIN. 2 1/2" x 2 1/2" MIN. 2 1/2" x 2 1/2"


TO THE BOTTOM OF STEEL FLANGE
5/8" TYPE "X" GPDW 5/8" TYPE "X" GPDW UL RATED 4 PCF DENSITY MINERAL WOOL 430 East 51st Place
BATT INSULATION STRIPS TO FILL GAP AT UL RATED VOID SEALANT TO
BOTTOM OF BEAM & TOP OF GPDW COMPLETELY FILL GAP; 1/4" MAX JOINT
Chicago, Illinois 60615
ACOUSTICAL CEILING SOUND ATTENUATION
METAL STUD RUNNER TRACK METAL STUD RUNNER TRACK SPRAY FILL MATERIAL COMPLETELY OVER SPACE; OVERLAP 1/2" ON GPDW.
GRID, SEE ID SHEETS BLANKET
SEE D1.X & D2.X FOR RATED PARTITION NOTES SEE D1.X & D2.X FOR RATED MINERAL WOOL & OVERLAP GPDW BY 1/2"
SEE D1.X & D2.X FOR RATED PARTITION NOTES Project Name
PARTITION NOTES SEE D1.X & D2.X FOR RATED PARTITION NOTES END OF GRID BRACKET 5/8" GPDW (U.N.O.)
5/8" TYPE "X" GPDW (USG
RATED TOP OF GPDW RATED TOP OF GPDW RATED TOP OF GPDW WALL RATED TOP OF GPDW WALL PARTITION FIRECODE 'C') @ RATED PARTITION TYPES & DETAILS
WALLS
WALL PARTITION WALL PARTITION PARTITION OF STEEL BEAM OFFSET FROM STEEL BEAM
(UL SYSTEM #HW-D-001 & DW-D-002) (UL SYSTEM #HW-D-001 & DW-D-002) (UL SYSTEM #HW-D-0259) (UL SYSTEM #HW-S-0096)
1 & 2 HR RATING 1 & 2 HR RATING 1 & 2 HR RATING 1 & 2 HR RATING
Sheet Name
2 FIRE PENETRATIONS & NOTES 1 SECTION DETAIL AT TOP OF WALL - DX.2
A7-1 N.T.S. A7-1 N.T.S. Drawing No. A7-1
DOOR SCHEDULE GENERAL NOTES: DOORS SCHEDULE GENERAL NOTES: DOORS & FRAMES
OPENING SIZE DOOR FRAME 1. THE BELOW ITEMS ARE COMMENTS ABOUT DOOR SCHEDULE: 1. ALL DOOR CLOSERS & OPENING FORCE SETTINGS FOR
FIRE RATING ACCESSIBLE DOORS TO COMPLY W/ ACCESSIBILITY STANDARDS.
DOOR NO. WIDTH HGT. TYPE. MATL. (MINS) U.C. TYPE MATL. JAMB HEAD SILL HDW. NO. REMARKS 2. DOOR#: INDICATES THE DOOR NUMBER ON FLOOR PLANS. FIRE RATED DOORS SHALL HAVE THE MIN. OPENING FORCE
100 LEVEL ALLOWABLE BY LOCAL CODE AUTHORITIES.
3. OPENING SIZE (WXH): INDICATES THE OPENING WIDTH (W)
BETWEEN JAMBS & OPENING HEIGHT (H) BETWEEN SUBSTRATE 2. ALL DOORS & HARDWARE TO COMPLY WITH ACCESSIBILITY
100A.A 4' - 0" 8' - 0" E1 ALUM EX ALUM AC1.7 REPLACE CENTER PIVOT ENTRY DOOR. AUTOMATIC OPERATOR, PEDESTAL MOUNT PUSH BUTTON, CARD @ FLOOR & BOTTOM OF THE HEAD. STANDARDS. SEE PLANS FOR DOOR SYMBOL. ALL DOORS WITH 3
READER, EX. OPENING, VERIFY EXISTING OPENING SIZE. SIDED FRAME (U.N.O. ON DOOR SCHEDULE OR ELEVATIONS).
100A.B 4' - 0" 8' - 0" E1 ALUM EX ALUM AC1.6 REPLACE CENTER PIVOT ENTRY DOOR. AUTOMATIC OPERATOR, EX. OPENING, VERIFY EXISTING OPENING SIZE. 4. ALL DOORS ARE 1 3/4" THICK (U.N.O.)
100B 3' - 4" 7' - 0" A1 WD F3 HM HJ-D1 HJ-D1 1.3 3. ALL DOORS USED IN CONJUNCTION W/EXITS SHALL BE SO
5. DOOR TYPE: INDICATES DOOR TYPE, SEE DOOR TYPES ON A7-2. ARRANGED AS TO BE READILY OPENED WITHOUT THE USE OF A
100C 3' - 4" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 1.3
KEY (U.N.O) FROM THE SIDE FROM WHICH EGRESS IS MADE.
100D 6' - 0" 7' - 0" EX HM EX HM - EXISTING DOOR AND FRAME TO REMAIN. ADD CARD READER. 6. ALL DOORS ARE FLUSH CONSTRUCTION (U.N.O.).
102 3' - 0" 8' - 0" D1 ALUM F1 ALUM HJ-D1 HJ-D1 5.1 4. ALL FIRE-RATED DOORS SHALL HAVE FIRE-RATED CLOSERS; ALL
103 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 4.0 7. DOOR MATL: INDICATES MATERIAL (MATL) OF DOOR. SEE SPEC. DOOR FRAMES & HARDWARE TO BE FIRE LISTED TO MATCH FIRE
Department of Capital Planning & Policy
104 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 4.0
FOR SPECIFIC FINISH. DOOR RATINGS. Bureau of Asset Management
105 3' - 0" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 4.0 WD = WOOD PW = PAINTED WOOD 5. ALL EXIT DOORS SERVING MORE THAN 200 PERSONS SHALL HAVE
Notice: This drawing has not been published and is the
106 3' - 4" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 5.0 HM = HOLLOW METAL HC = HOLLOW CORE WOOD sole property of Cook County. It is loaned to the borrower
PANIC HARDWARE.
107 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN. REFINISH EXISTING DOOR ALUM = ALUMINUM GL = GLASS (W/OUT METAL STILES) for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
108 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN. REFINISH EXISTING DOOR 6. PROVIDE KNURLED LEVER HARDWARE HANDLES AT ELECTRICAL,
8. DOOR LABEL: INDICATES FIRE RATED LABEL (LBL) OF DOOR & return it upon request and agrees that it shall not be
109 3' - 0" 7' - 0" A1 WD F1 HM HJ-C11 HJ-C11 4.0 MECHANICAL & HAZARDOUS AREAS PER ACCESSIBILITY
FRAME. reproduced, copied, loaned, or otherwise disposed of
STANDARDS.
110 3' - 0" 7' - 0" A1 WD F1 HM HJ-C11 HJ-C11 4.0 directly or indirectly, nor used for any purpose other than
111 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 AC1.5 (-) = NO LABEL for which it is furnished, in whole or part.
7. COORDINATE ALL SECURITY ACCESS DEVICES W/OWNER.
112 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 3.0 A LABEL 120 = 120 MINUTES = 2 HR
113 3' - 0" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 2.2 B LABEL 90 = 90 MINUTES = 1 1/2 HR 8. ALL HM & WOOD DOORS HAVE 6 1/2" WIDE DOOR STILES (U.N.O.)
C LABEL 45 = 45 MINUTES = 3/4 HR W/ 7" MIN. HIGH TOP RAIL.
113A 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 6.0
113B 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 6.0 9. U.C.: COORDINATE DOOR SIZE W/ SPECIFIC UNDERCUT (UC) & 9. ALL ALUM DOORS HAVE 5" WIDE STILES (U.N.O.) & G.C. TO COORD.
114 3' - 6" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 6.0 FLOOR MATERIAL THICKNESS ABOVE FLOOR SUBSTRATE. W/ SPECIFIC HARDWARE.
117 3' - 6" 8' - 0" D1 ALUM F1 ALUM (-) = 5/8" TYPICAL (U.N.O.).
117A 3' - 6" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 6.0 10. BOTTOM STILE OF ALUM OR HM DOORS TO BE FLUSH WITH NO
10. FRAME TYPE: INDICATES FRAME TYPE, SEE FRAME TYPES ON EXPOSED SURFACE PLATES OR FASTENERS EXCEPT FOR
118 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 2.1 A7-2. SURFACE APPLIED KICKPLATES THAT ARE CALLED OUT IN
119 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 2.1 HARDWARE SCHEDULE.
120 3' - 6" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 2.1 11. FRAME MATL: INDICATES MATERIAL (MATL) OF FRAME. SEE NOTE
121 3' - 0" 7' - 0" B1 WD F1 HM HJ-D1 HJ-D1 2.1 ABOVE FOR ABBREVIATIONS. 11. NO "THRU BOLTING" ON DOORS OR FRAMES (PROVIDE ADEQUATE
122 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 2.1 OR 3.0 BLOCKING IN DOOR FOR CLOSER ATTACHMENT). NO EXPOSED
12. JAMB, HEAD & SILL: INDICATES HEAD, JAMB & SILL DETAILS FASTENERS OR SCREWS FOR HARDWARE AT DOORS, EXCEPT
123 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN SHOWN IN ARCHITECTURAL DRAWINGS. NUMBER IS USED FROM FOR F.H.W.S. FOR KICK PLATES.
124 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN TYP. DOOR DETAIL DRAWING SHEET A7-4 (U.N.O.); REFER TO ID
125A 3' - 6" 7' - 0" C1 HM F1 HM HJ-D40 HJ-D40 2.2 SERIES FOR INTERIOR SILLS. 12. RATED DOOR LOUVER TO HAVE FUSIBLE LINK; 24"X24" MAX.,
125B 6' - 0" 7' - 0" A2 HM F1 HM 1.0 COORD. SIZE W/ MECHANICAL DRAWINGS
13. HDW#: INDICATES HARDWARE (HDW) NUMBER THAT IS DEFINED
126 7' - 0" 7' - 0" EXISTING TO REMAIN. GARBAGE ENCLOSURE. IN FINISH HARDWARE SPEC. SECTION. 13. EXTERIOR DOOR FRAMES ARE GALVANIZED. EXTERIOR DOORS
127 7' - 0" 7' - 0" EXISTING TO REMAIN. GARBAGE ENCLOSURE. ARE INSULATED & GALVANIZED.
14. REMARKS: INDICATES ROOM LOCATION & SPECIFIC REMARKS
RELATING TO DOOR. 14. ALL DOOR FRAMES & HARDWARE TO BE RATED TO MATCH DOOR
LABEL.
GENERAL NOTES: INTERIOR GLAZING
15. SEE GLAZING NOTES THIS SHEET FOR GLASS LITE.
1. USE SAFETY GLAZING IN ALL DOORS.
16. ALL HM & ALUMINUM GLAZING STOPS TO BE FLUSH & SQUARE
A. C LABEL DOORS (45 MIN.) SHALL BE FIRE RATED. 1296 SQ. (NOT BEVELED) AND APPLIED W/F.H.M.S. (NO WRAP AROUND ON
IN. MAX. GLASS AREA "GLASS KITS" FOR HM GLAZING STOPS)
A1 A2 B1 B2 C1 C2 D1 E1 B. B LABEL (90 MIN.) GLASS SHALL BE FIRE RATED GLASS. 100
SQ. IN. MAX. GLASS AREA, WITH 12" MAX. DIMENSION 17. ALL FIRE-RATED DOORS SHALL HAVE FIRE-RATED CLOSERS;

DOOR TYPE - ELEVATIONS 2. ALL GLAZING IN FIRE-RATED HM OPENINGS TO BE FIRE-RATED 18. ALL DOOR CLOSER COVERS & COORDINATOR COVERS TO BE
1/8" = 1'-0" SAFETY GLAZING. FIELD PAINTED COLOR OF HM (U.N.O.). ALL DOOR CLOSERS ARE
ON ROOM SIDE OF DOOR (U.N.O.). NO DOOR CLOSERS ON
3. WIRE GLASS PATTERN TO BE SET 90°, NOT DIAGONAL. CORRIDOR SIDE UNLESS DOOR DIVIDES CORRIDOR.

4. USE SAFETY GLAZING IN FIXED OR OPERABLE LITES >18" IN 19. 3'-2" HIGH DOOR HANDLE TYP. OR MFR. STANDARD.
WIDTH ADJACENT TO A DOOR OR WITH SILLS BELOW 24" A.F.F.,
TO BE SAFETY GLAZING. (THIS IS IBC 2008 REVISE PER AHJ) 20. 3'-2" HIGH PUSH BAR @ PANIC HARDWARE OR MFR. STANDARD.

5. SEE A7-2 FOR TYPICAL FRAME PROFILES. 21. NO MANUFACTURER'S NAME PLATES ON ALUM. DOORS. G.C. TO
F1 F2 F3 REMOVE NAME PLATES ON DOORS AT NO ADDITIONAL COST.
6. SEE WALL TYPES FOR JAMB THROAT THICKNESS. Holabird & Root, LLC expressly disclaims any
22. 90 MINUTE LABELED DOORS UNLESS CALLED FOR SPECIFICALLY responsibility arising from any unauthorized use of these
FRAME TYPES - ELEVATIONS G1 = 1/4" CLEAR GLASS IN HARDWARE SPEC. FOR ASTRAGAL @ DOORS INTO ELEC. plans, drawings and notes. Any authorization must be in
SWITCH GEAR, MECH, & PUMP ROOMS AND EXTERIOR DOORS. writing.
1/8" = 1'-0"
GL-1 = 1" CLEAR INSULATED CLEAR GLASS
23. SEE TYPICAL HM DETAILS FOR NESTED STUDS This drawing copy may have been reproduced at a size
W1 = FIRE RATED GLASS different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.


5 5/8" 7 1/8"
TYP. NOTES @ 6" CMU PARTITION 1" x 5/8" REMOVABLE
SEE HJ-C11
FOR NOTES H.M. STOP WITH F.H.M.S.
6" CMU GLASS GLAZED AGAINST
FRAMED STOP

2" TYP.
8"X16" BOND BEAM W/ 2#5
BARS @ HEAD, 6" BEARING FOR FRAMES W/ 3 OR MORE HORIZONTAL
TYP. H.M. FRAME W/ 1/2" GPDW
ADJUSTABLE UL-RATED LEAFS USE 16 GAUGE BLINDS ROOM SIDE
WRAP-AROUND ENDS PARTITION
ANCHOR @ MASONRY JAMB NESTED STUDS FROM FLOOR AS REQUIRED

1 15/16", TYP.
GROUT SOLID @ RATED FRAME TO STRUCT. ABOVE (COORD. 5/8" GPDW
THROAT=PARTITION WIDTH
2"

1/2" (SEE SPEC. FOR NON RATED FRAME ANCHORS W.


FRAMES) 8 1/8" DETAILS)

1/2"
1/2" TYP. DIMENSION FOR H.M. FRAMES @ H.M. DOOR
6 5/8" 1" 2"
6" CMU
GPDW W/ DOUBLE

1/2"
STUDS
HJ-C11 HJ-C12 1 09/07/2018 ISSUED FOR BID

1 15/16", TYP.
1" = 1'-0" 1" = 1'-0" 2" , TYP. 2" , TYP. 5/8" 2" , TYP. No. Date Issue

5" MIN.
TYP. NOTES FOR H.M. FRAME
AT GPDW PARTITION Project Number 15849

4 7/8"
WALL @ 90º DEGREE IS OFFSET 6 1/8" TYP. H.M. FRAME PROFILES TYP. H.M. FRAME TYP. H.M. HEAD & SILL Drawn S. DENNY
2" FROM JAMB AS SHOWN (TYP.) SEE HJ-D1 1" = 1'-0" 1" = 1'-0" 1" = 1'-0" Checked K. BOYER
FOR NOTES
5/8" TYPE "X" GPDW (USG FIRE Proj. Arch./Eng. K. SCHUSTER
2" TYP.

CODE 'C')
GPDW W/ DOUBLE STUDS (3 5/8" 20 NEW GBDW FURRING
1/2" GAGE @ HEAD & JAMB) GPDW W/ DOUBLE STUDS EXISTING EXTERIOR CMU WALL
SPOT GROUT @ NON-RATED FRAMES
PER SPEC. Provident Hospital - Renal
2" TYP.

7 1/8"
5 7/8" GROUT SOLID @ RATED FRAMES
Dialysis Center
UL RATED ANCHORS @ RATED
WD DOOR 1" ACOUSTICAL GASKET/SEALANT
FRAMES SINGLE PANE GLASS
5/8" GPDW BET. MULLION & PARTITION WALL

HJ-D1 HJ-D2
1" = 1'-0" 1" = 1'-0" DRYWALL F-BEAD AT
1 3/4" ,TYP. EXISTING HM FRAME
EXPOSED ENDS OF ALL
GPDW NEW HM DOOR PANEL
4 1/2"

4 1/2"

SEE PLANS
SEE PLANS SEE HJ-D1
4 7/8" CLIP ANGLES ATTACHED TO HM
FOR NOTES SEE HJ-D1 FOR DOOR AND FRAME @ 24" O.C.
NOTES 1 3/4" 7/8"
430 East 51st Place
2 1/2" STUDS W/ 2/12" Chicago, Illinois 60615
STUDS CROSS DOUBLE 2 1/2" STUDS TYP. ALUM. FRAME PROFILES TYP. ALUM HEAD & SILL DETAIL OF EXTERIOR DOOR CLOSURE
BRACING @ 24" O.C. 1" = 1'-0" 1" = 1'-0" 1" = 1'-0"
Project Name
S.M. BRACE TO
SUPPORT STUDS OFF 4
SEALANT AND
6 3/8" BACKER ROD 5 7/8" 7/8" PARTITION DOOR SCHEDULE, BORROWED
SEALANT AND LIGHT SCHEDULE, ELEVATIONS,
BACKER ROD
& DETAILS
Sheet Name
HJ-D40 HJ-D43
1" = 1'-0" 1" = 1'-0" Drawing No. A7-2
A8-3

5
2
NARC-01

1 REUN-01 REUN-01 GLBH-01 EW-01

15 COSH-01 B
16 A8-2
FE-01 MED. PREP. FE-01
17 115 1' - 4"
DRDU-06
EXAM
106 6" 3' - 8" 2' - 9" 2' - 9" 2' - 10"
Department of Capital Planning & Policy
11
CH-4
224000.03 102800.09
P
Bureau of Asset Management
DISE-01

5"
14 12 102800.09 102800.08 Notice: This drawing has not been published and is the

3' - 0"
A8-2
TAEP-01 DI-01
102800.08 224000.05 sole property of Cook County. It is loaned to the borrower

3'-0"
13 PRIVATE 122413.01
6 for their confidential use only. In consideration of the loan
R
A8-6 PAT./ISOLATION 21 ACCESS DOOR of this drawing, the borrower promises and agrees to
STWB-01 4 117 return it upon request and agrees that it shall not be
A8-6 20 A8-2 18 reproduced, copied, loaned, or otherwise disposed of

5' - 0"
10

3'-1"
102800.08 DRCL-01
122413.01 directly or indirectly, nor used for any purpose other than
19 A8-2 3
TV-01 9 A8-2 7 6
102800.09 for which it is furnished, in whole or part.
A8-2 5 A8-2
TVAR-01
8 DI-01 DRCL-02 224000.03
NURSE

3'-2"
COSH-01 TYP

3' - 0"
GLBH-01 5 STATION GLBH-01 DI-01 3
BINS-01
A8-6 A8-6
TVAR-01
27 C D SOLID SURFACE
COUNTERTOP
24 A8-2 26 EW-01

5' - 0"
DRCL-01
25
COPM-01
SCHT-01
C C
RECEPTION TVAR-01
1 105 102800.08
A8-6 102800.08 102800.09
SCI-01 PROVIDE BLOCKING
224000.05 224000.03
WHERE NECESSARY FOR
2 TV MONITOR ARM
102800.09 4 COSH-01

DEPRESSED A8-2
SLAB AT SCALE

1
A8-1
EXAM & RECEPTION
1/4" = 1'-0" [REF: 1/ A2-1]
2
A8-1
NURSE STATION & MEDICAL PREP.
1/4" = 1'-0" [REF: 1/ A2-1] A8-1
3 PRIVATE PAT./ISOLATION
1/4" = 1'-0" [REF: 1/ A2-1]
4
A8-1
TYPICAL DIALYSIS STATION
1/4" = 1'-0" [REF: 1/ A2-1]

SOILED CLEAN
GLBH-01 STORAGE SUPPLY
118 119
CASU-01 B
CASU-02
B
12 A8-3

CASU-01
CASU-02

EW-01 Holabird & Root, LLC expressly disclaims any


TYP responsibility arising from any unauthorized use of these
3 DI-01 DI-01 DI-01
WATER plans, drawings and notes. Any authorization must be in
A8-6
TREATMENT writing.
GLBH-01
22
125
A8-2 This drawing copy may have been reproduced at a size
EW-02
different than originally drawn. The Owner and Architect
EQUIP. assume no responsibility for use of incorrect scale.
REPAIR COORDINATE WITH
PLUMBING DRAWINGS FOR Drawings are not to be scaled.
120
WATER TREATMENT LAYOUT
Not published - All rights reserved.

FE-01

EW-02 23 A8-2
C
LAB C
GLBH-01
REUN-01 121

5
A8-1
BIOHAZARD, CLEAN SUPPLY, EQUIP. REPAIR, & LAB
1/4" = 1'-0" [REF: 1/ A2-1]
6
A8-1
WATER TREATMENT
1/4" = 1'-0" [REF: 1/ A2-1]
1 09/07/2018 ISSUED FOR BID
No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

KEYNOTES LEGEND
REF#
102800.08 PAPER TOWEL DISPENSER
102800.09 SOAP DISPENSER
122413.01 MANUALLY OPERATED ROLLER SHADES
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/
PIPE COVER 430 East 51st Place
224000.05 LAVATORY - DROP-IN SINK Chicago, Illinois 60615

*SEE Q SERIES FOR OWNER


Project Name
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS
INTERIOR ENLARGED PLANS
*SEE A6-1 FOR MOUNTING HEIGHTS
AND GENERAL NOTES FOR WALL
MOUNTED ITEMS Sheet Name

Drawing No. A8-1


3
5
A8-6
A8-6

10 1/2"
3' - 0" 3' - 6" 3' - 0" 4' - 6" 3' - 0" 4' - 6" 3' - 0" 4' - 6" 3' - 0" ± 5' - 3" 3' - 6" 3' - 0" 4' - 6" 3' - 0" 4' - 6" 1' - 0" 3' - 0" 4' - 6" 3' - 0" 5' - 0" 3' - 0" 5' - 0" 3' - 0" ± 4' - 6"
BUTT GLAZED
TVAR-01 TVAR-01 TVAR-01 GLASS SPLASH
OPEN
GUARD 102800.09
1' - 10" SS1 102800.08

3 TYP 102800.08 224000.03


Department of Capital Planning & Policy
102800.09 COSH-01
A8-6
SCI-01
WP1
Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
102800.09 WP1
1/2" ALUM. WP2 DIALYSIS WALL T.V. ON ARTICULATING WP2 WP2 END PANEL WALL BASE, TYP. for their confidential use only. In consideration of the loan
224000.03 WALL BASE, TYP.
REVEAL TYP. BOX, TYP. ARM, TYP. of this drawing, the borrower promises and agrees to
102800.08 SCALE READOUT return it upon request and agrees that it shall not be
MOUNTED ON reproduced, copied, loaned, or otherwise disposed of
ADJACENT WALL directly or indirectly, nor used for any purpose other than

1
A8-2
TREATMENT AREA - SOUTH
1/4" = 1'-0" [REF: 1/ A2-1]
2
A8-2
TREATMENT AREA - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
3
A8-2
TREATMENT AREA - NORTH
1/4" = 1'-0" [REF: 1/ A2-1]
4
A8-2
NURSE STATION - EXT. EAST
1/4" = 1'-0" [REF: 1/ A2-1]
for which it is furnished, in whole or part.

Sim Sim Sim


4 12 4 4 5 4
A8-6 A8-4 A8-6 A8-6 A8-6 A8-6

SCHT-01 TV-02
OPEN OPEN OPEN OPEN
BUTT GLAZED
GLASS SPLASH BUTT GLAZED
OPEN BUTT GLAZED 5 Sim OPEN
GUARD OPEN GLASS SPLASH OPEN OPEN A8-6
GUARD SS1 SS1 GLASS SPLASH GLBH-01 SOLID SURFACE
SS1 GLBH-01
EW-01 GUARD COUNTERTOP
OPEN EW-01
102800.09
SOLID SURFACE AND CAP
102800.08
EW-01 COUNTERTOP
OPEN 224000.05 OPEN OPEN SCI-01 AND CAP SCALE SCI-01 OPEN
224000.03
READOUT
WP1 SOLID SURF. PL1 WP1 WP1 PL1 WP1 WALL BASE, WP1 PL1 WALL BASE,
224000.03 WALL BASE, END PANEL PL1 WP1
SILL, TYP. TYP. 6 Sim TYP. TYP.
A8-6 WALL BASE,
TYP.

5
A8-2
NURSE STATION - EXT. NORTH
1/4" = 1'-0" [REF: 1/ A2-1]
6
A8-2
NURSE STATION - EXT. SOUTH
1/4" = 1'-0" [REF: 1/ A2-1]
7
A8-2
NURSE STATION - INT. NORTH
1/4" = 1'-0" [REF: 2/ A8-1]
8
A8-2
NURSE STATION - INT. EAST
1/4" = 1'-0" [REF: 2/ A8-1]
9
A8-2
NURSE STATION - INT. SOUTH
1/4" = 1'-0" [REF: 2/ A8-1]
Sim Sim
6 5 2
A8-6 A8-4 A8-4 Sim Sim Sim
4 1 3
2' - 8" 2' - 6" 10" A8-4 A8-4 A8-4
AUDIO/VISUAL ALARM SOFFIT FLUSH
2' - 6" 2' - 6" 2' - 6" 2' - 6" 1' - 9" W/ FACE OF
CLOCK VIDEO SOFFIT OR SOFFIT OR F9.2 CABINETS
TV-02 PLAM PANEL PLAM PANEL POWER
GLAZING IN LIGHT SWITCH UNDER
ALUMINUM HEALTH MONITOR CABINET LIGHT

2' - 6"

2' - 6"

2' - 6"
THERMOSTAT NARC-01
CH-4
3' - 10"

STOREFRONT
9' - 11 1/2"

COSH-01 DISPLAY
DISE-01
CH-4 WALL PHONE DATA GLBH-01
BUTT GLAZED GLASS

2' - 2"

2' - 2"

2' - 2"
CHAIR RAIL

7' - 6"
SPLASH GUARD HAND SANITIZER POWER DATA GLBH-01 COSH-01
FE-01

4' - 6"
POWER Holabird & Root, LLC expressly disclaims any
3' - 8"

3' - 6"

2' - 10"

2' - 10"

2' - 10"
SOLID SURFACE WALL BASE, TYP. REUN-01 REUN-01 responsibility arising from any unauthorized use of these
1' - 6"

COUNTERTOP plans, drawings and notes. Any authorization must be in


AND CAP writing.
2' - 0" 6" 4' - 0" 6" 4' - 3" 1' - 3"1' - 3"1' - 3" 2' - 6" 1' - 3"
WALL BASE, 2' - 0"
TYP. This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

10 NURSE STATION - INT. WEST


A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
11 EXAM - WEST
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
12 EXAM - NORTH
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
13 EXAM - EAST
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
14 EXAM - SOUTH
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
15 MEDICAL PREP. - WEST
A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
Not published - All rights reserved.

TYP
3
6 A8-6
A8-6
9' - 2"
EQ 2" EQ 2" EQ 2" EQ
3' - 6"
GLAZING IN ALUM.
STOREFRONT SOFFIT OR GLAZING IN ALUM.
PLAM PANEL 102800.08
STOREFRONT
102800.09
TVAR-01 ALUMINUM STOREFRONT
3' - 6"

3' - 6"

224000.03
WITH SAFETY GLAZING

8' - 0"

8' - 0"
TVAR-01 COSH-01 TVAR-01
UNDER 224000.03 DIALYSIS WALL
CABINET BOX, TYP. 1 09/07/2018 ISSUED FOR BID
LIGHT
3' - 8"

3' - 8"

No. Date Issue


DRDU-06 REUN-01 DRDU-06 WP2

4'-6" 3'-0"
Project Number 15849
WALL BASE, TYP. WALL BASE, TYP. WP2 WALL BASE, TYP.
WALL BASE, TYP. Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER
16 MEDICAL PREP. - SOUTH
A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
17 MEDICAL PREP. - EAST
A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
18 PRIVATE PAT./ISOLATION - NORTH
A8-2 1/4" = 1'-0" [REF: 3/ A8-1]
19 PRIVATE PAT./ISOLATION - EAST
A8-2 1/4" = 1'-0" [REF: 2/ A6-2]
20 PRIVATE PAT./ISOLATION - SOUTH
A8-2 1/4" = 1'-0" [REF: 3/ A8-1]
21 PRIVATE PAT./ISOLATION - WEST
A8-2 1/4" = 1'-0" [REF: 2/ A6-2]

Sim TYP Sim Sim Sim Sim Provident Hospital - Renal


3
A8-2 INTERIOR ELEVATIONS

3 6 3 2 9 4
A8-4 A8-6 A8-4 A8-4 A8-6 A8-4 A8-4 Dialysis Center
3' - 0" 2' - 6" 2' - 6" 4' - 0" 3' - 0" 3' - 0" 2' - 6" 2' - 4 1/2" 3' - 0" 2' - 6" 2' - 9 1/2"

SOFFIT FLUSH SOFFIT FLUSH


SOFFIT FLUSH W/FACE OF KEYNOTES LEGEND
SOFFIT FLUSH W/ FACE OF W/FACE OF
CABINETS SOFFIT FLUSH
W/ FACE OF CABINETS CABINETS REF#
CABINETS 2 TYP W/FACE OF
2' - 6"

2' - 6"

CABINETS 102800.08 PAPER TOWEL DISPENSER


2' - 6"

2' - 6"

2' - 6"
A8-6
102800.09 SOAP DISPENSER
UNDER CABINET
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/
2' - 2"

2' - 2"

EW-02 LIGHT GLBH-01 EW-02 UNDER CABINET


2' - 0"

2' - 0"

2' - 0" UNDER PIPE COVER


LIGHT UNDER TACKBOARD 430 East 51st Place
DIALYSIS WALL BINS-01
BINS-01 CABINET
CABINET 224000.05 LAVATORY - DROP-IN SINK Chicago, Illinois 60615
BOX, TYP. EYE WASH LIGHT
2' - 10"

2' - 10"

COPM-01 COPM-01 LIGHT COPM-01


2' - 6"

2' - 6"

2' - 6"

2' - 6"

REUN-01 *SEE Q SERIES FOR OWNER


Project Name
WP2 EQUIPMENT SCHEDULE REFERENCED
1' - 6" 3' - 6" 2' - 6" 2' - 6" 2' - 9 1/2"
3' - 6" 1' - 6" 3' - 1 1/2" WALL BASE, TYP. WALL BASE, TYP. IN THESE PLANS
WALL BASE, TYP. INTERIOR ELEVATIONS
*SEE A6-1 FOR MOUNTING HEIGHTS
09/07/2018 ISSUED FOR BID

AND GENERAL NOTES FOR WALL


MOUNTED ITEMS Sheet Name
22 EQUIP. REPAIR - SOUTH 23 LAB - SOUTH 24 RECEPTION - SOUTH 25 RECEPTION - EAST 26 RECEPTION - NORTH 27 RECEPTION - WEST
A8-2 1/4" = 1'-0" [REF: 5/ A8-1] A8-2 1/4" = 1'-0" [REF: 5/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
Drawing No. A8-2
TV-01 TV-02

8' - 0"
CH-12

5' - 0"
CAV-01 CAV-01 CAV-01 OPEN OPEN

DEAE-01
CASU-03
Department of Capital Planning & Policy
WALL BASE, TYP. WALL BASE, TYP. WALL BASE, TYP. WALL BASE, TYP. Bureau of Asset Management
CLEAN EXISTING CMU AT WALL BASE, TYP. Notice: This drawing has not been published and is the
FORMER PLANTER AREA sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
1
A8-3
CONFERENCE - NORTH
1/4" = 1'-0" [REF: 1/ A2-1]
2
A8-3
CONFERENCE - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
3
A8-3
CONFERENCE - SOUTH
1/4" = 1'-0" [REF: 1/ A2-1]
4
A8-3
CONFERENCE - WEST
1/4" = 1'-0" [REF: 1/ A2-1]
5
A8-3
CORRIDOR 100C - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
Sim Sim Sim for which it is furnished, in whole or part.
3 7 8 Sim
A8-4 A8-4 A8-4 10
10'-6"
A8-4
CLOCK

3' - 0" 2' - 6" 1' - 6" 2' - 6"

1' - 5"
064116.02
UNDER
CABINET LIGHT

2' - 6"
CH-4 TV-01
MICRO-01 MICRO-01
P.LAM
COUNTERTOP

7' - 7"
W/BACKSPLASH

5' - 0"
REFU-01

WALL BASE, TYP. 3' - 0" 2' - 0" 2' - 0" 2' - 6" WALL BASE, TYP. WALL BASE, TYP.

6
A8-3
CORRIDOR 100C - WEST
1/4" = 1'-0" [REF: 1/ A2-1]
7
A8-3
STAFF - NORTH
1/4" = 1'-0" [REF: 1/ A2-1] A8-3
8 STAFF - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
9
A8-3
STAFF - WEST
1/4" = 1'-0" [REF: 1/ A2-1]

Sim
2 11
A8-6 A8-4
CLOCK

TV-01
TB-04 TB-03
224000.03
LOCKERS GLBH-01
OPEN
BEYOND CASU-02 CASU-02

PL1
WALL BASE, TYP. WALL BASE, TYP. WALL BASE, TYP. Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.
10 WAITING ROOM - NORTH 11 WAITING ROOM - WEST
A8-3 1/4" = 1'-0" [REF: 1/ A2-1] A8-3 1/4" = 1'-0" [REF: 1/ A2-1] 12 SOILED STORAGE - SOUTH
A8-3 1/4" = 1'-0" [REF: 5/ A8-1]
This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

KEYNOTES LEGEND
REF#
064116.02 PLASTIC LAMINATE LOCKER.
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ 430 East 51st Place
PIPE COVER Chicago, Illinois 60615

*SEE Q SERIES FOR OWNER


Project Name
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS
INTERIOR ELEVATIONS
*SEE A6-1 FOR MOUNTING HEIGHTS
AND GENERAL NOTES FOR WALL
MOUNTED ITEMS Sheet Name

Drawing No. A8-3


1'-0"
1'-0" 1'-0"

1'-0"

VARIES
SCHEDULED CEILING

VARIES
SCHEDULED CEILING SCHEDULED CEILING

VARIES
VARIES
PLAM CLOSURE PANEL SCHEDULED CEILING
PLAM CLOSURE PANEL

WOOD BLOCKING AS REQUIRED, TYP. PLAM CLOSURE PANEL


PLAM CLOSURE PANEL
WOOD BLOCKING AS REQUIRED, TYP.
WOOD BLOCKING AS REQUIRED, TYP. WOOD BLOCKING AS REQUIRED, TYP.

SEE ELEVATION

VARIES, SEE ELEVATION


2' - 6"

METAL SHELF SUPPORTS

2'-0" OR 2'-6"
METAL SHELF SUPPORTS
2' - 8"

METAL SHELF SUPPORTS (2) 3/4" BLACK MELAMINE


METAL SHELF SUPPORTS Department of Capital Planning & Policy
(2) 3/4" WHITE MELAMINE
ADJUSTABLE SHELVES (2) 3/4" BLACK MELAMINE Bureau of Asset Management

2' - 6"
ADJUSTABLE SHELVES

2' - 6"
(2) 3/4" BLACK MELAMINE ADJUSTABLE SHELVES

2' - 8"
ADJUSTABLE SHELVES WALL MOUNTED CABINET Notice: This drawing has not been published and is the
WALL MOUNTED CABINET CONSTRUCTED OF 3/4" WHITE WALL MOUNTED CABINET sole property of Cook County. It is loaned to the borrower
CONSTRUCTED OF 3/4" WHITE WALL MOUNTED CABINET MELAMINE INTERIOR AND PLASTIC CONSTRUCTED OF 3/4" WHITE
2"

MELAMINE INTERIOR AND PLASTIC CONSTRUCTED OF 3/4" WHITE LAMINATE VENEER EXTERIOR ON for their confidential use only. In consideration of the loan
MELAMINE INTERIOR AND PLASTIC
LAMINATE VENEER EXTERIOR ON
VARIES, SEE ELEVATION

MELAMINE INTERIOR AND PLASTIC ALL EXPOSED SIDES LAMINATE VENEER EXTERIOR ON of this drawing, the borrower promises and agrees to
ALL EXPOSED SIDES LAMINATE VENEER EXTERIOR ON ALL EXPOSED SIDES

2"
return it upon request and agrees that it shall not be

2"
ALL EXPOSED SIDES LOW PROFILE UNDER CABINET

SEE ELEVATION
LOW PROFILE UNDER CABINET reproduced, copied, loaned, or otherwise disposed of

VARIES, SEE ELEVATION


LIGHT WHERE INDICATED ON RCP GPDW SURFACE
LIGHT WHERE INDICATED; SEE RCP
2' - 1"
GPDW SURFACE directly or indirectly, nor used for any purpose other than
1 1/2"

1-1/2" SOLID SURFACE 2' - 1" GPDW SURFACE 2' - 1" 1-1/2" SOLID SURFACE COUNTERTOP for which it is furnished, in whole or part.
SCHEDULED COUNTERTOP -
COUNTERTOP W/ BACKSPLASH / PROVIDE BACKSPLASH/SIDESPLASH 2' - 1"
4"

SIDESPLASH WHERE INDICATED; WHERE THE COUNTER IS IN REFER TO ELEVATIONS FOR


SEE ELEVATIONS SCHEDULED COUNTERTOP - COUNTER FINISH. 1-1/2" SOLID

4"
CONTACT W/ ADJACENT WALL
PROVIDE BACKSPLASH/SIDESPLASH SURFACE TO BE USED WHERE
6"

5 1/2"
1 7/8" 4"
WHERE THE COUNTER IS IN

2" 5"
ADA COMPLIANT DROP-IN SINK NOTED.
(2) 3/4" WHITE MELAMINE W/ REAR DRAIN OUTLET CONTACT W/ ADJACENT WALL
ADJUSTABLE SHELVES
KNEE

VARIES; SEE ELEVATIONS


SPACE MAY BE UTILIZED FOR

2' - 6" OR 2' - 10"


SINK W/ REAR DRAIN OUTLET SPACE
2' - 10"

EQUIPMENT OR ROLLING
1' - 10 1/2"

CABINETS

1' - 6"
2' - 10"
BASE CABINET CONSTRUCTED REMOVABLE 3/4" MDF PANEL W/
OF 3/4" WHITE MELAMINE PLASTIC LAMINATE EXPOSED

2' - 10"
2' - 8 1/8"
INTERIOR AND PLASTIC SIDES & EDGES; PROVIDE Z- CONCEALED 1-1/2" x 1-1/2" x
LAMINATE VENEER EXTERIOR CLIPS FOR PANEL REMOVAL; NO BASE CABINET CONSTRUCTED 3/16" STEEL BRACKET @ 48" ON
ON ALL EXPOSED SIDES EXPOSED FASTENERS OF 3/4" WHITE MELAMINE CENTER
INTERIOR AND PLASTIC WALL TILE - REFER TO
4"

9"
REMOVABLE PANEL W/ BASE AS LAMINATE VENEER EXTERIOR ELEVATION
3" 1' - 9" SCHEDULED ON ALL EXPOSED SIDES
2' - 0" 11" 6" 2' - 0"

1
A8-4
SECTION DETAIL - BASE CABINET W/ TOP DRAWER
N.T.S.
2
A8-4
SECTION DETAIL - BASE CABINET W/ ADA SINK
N.T.S. A8-4
3 SECTION DETAIL - BASE CABINET W/ SINK
N.T.S.
4
A8-4
SECTION DETAIL - CONCEALER BRACKET
N.T.S.

1'-0" 1'-0" 1'-0"

VARIES
VARIES SCHEDULED CEILING SCHEDULED CEILING SCHEDULED CEILING

VARIES
PLAM CLOSURE PANEL

PLAM CLOSURE PANEL PLAM CLOSURE PANEL


WOOD BLOCKING AS REQUIRED, TYP.
WOOD BLOCKING AS REQUIRED, TYP. WOOD BLOCKING AS REQUIRED, TYP.
WALL MOUNTED CABINET
METAL SHELF SUPPORTS METAL SHELF SUPPORTS
CONSTRUCTED OF 3/4" WHITE

2' - 6"
2' - 8"
(2) 3/4" BLACK MELAMINE MELAMINE INTERIOR AND PLASTIC (2) 3/4" BLACK MELAMINE
ADJUSTABLE SHELVES LAMINATE VENEER EXTERIOR ON ADJUSTABLE SHELVES
2' - 6"

2' - 6"
2' - 8"

2' - 8"
ALL EXPOSED SIDES
WALL MOUNTED OPEN-SHELF WALL MOUNTED CABINET
CABINET CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4" WHITE
WHITE MELAMINE INTERIOR AND MICROWAVE SHELF MELAMINE INTERIOR AND PLASTIC

2"
PLASTIC LAMINATE VENEER LAMINATE VENEER EXTERIOR ON
EXTERIOR ON ALL EXPOSED SIDES ALL EXPOSED SIDES

VARIES, SEE ELEVATION


2"

2"
GPDW SURFACE GPDW SURFACE
LOW PROFILE UNDER CABINET
LOW PROFILE UNDER CABINET LIGHT WHERE INDICATED; SEE RCP LOW PROFILE UNDER CABINET Holabird & Root, LLC expressly disclaims any
LIGHT WHERE INDICATED; SEE RCP LIGHT WHERE INDICATED; SEE RCP
responsibility arising from any unauthorized use of these

1 1/2"
GPDW SURFACE GPDW SURFACE
2' - 1" 2' - 1" 2' - 1" 2' - 1" plans, drawings and notes. Any authorization must be in
1 1/2"

1 1/2"

1 1/2"
1-1/2" SOLID SURFACE 1-1/2" SOLID SURFACE 1-1/2" SOLID SURFACE 1-1/2" SOLID SURFACE writing.

4"
COUNTERTOP W/ BACKSPLASH / COUNTERTOP W/ BACKSPLASH / COUNTERTOP W/ BACKSPLASH / COUNTERTOP W/ BACKSPLASH /
4"

4"

4"
SIDESPLASH WHERE INDICATED; SIDESPLASH WHERE INDICATED; SIDESPLASH WHERE INDICATED; SIDESPLASH WHERE INDICATED;
SEE ELEVATIONS SEE ELEVATIONS SEE ELEVATIONS SEE ELEVATIONS This drawing copy may have been reproduced at a size
DRAWERS CONSTRUCTED DRAWERS CONSTRUCTED DRAWERS CONSTRUCTED DRAWERS CONSTRUCTED
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.

2' - 6" OR 2' - 10"


OF 3/4" WHITE MELAMINE OF 3/4" WHITE MELAMINE OF 3/4" WHITE MELAMINE OF 3/4" WHITE MELAMINE
2' - 6" OR 2' - 10"

2' - 6" OR 2' - 10"

2' - 4 1/2"
SIDES WITH 1/2" WHITE SIDES WITH 1/2" WHITE SIDES WITH 1/2" WHITE SIDES WITH 1/2" WHITE Drawings are not to be scaled.
2' - 0 1/2"

2' - 0 1/2"

2' - 0 1/2"
MELAMINE BOTTOM MELAMINE BOTTOM MELAMINE BOTTOM MELAMINE BOTTOM

2' - 6"
SEE ELEVATIONS FOR SEE ELEVATIONS FOR SEE ELEVATIONS FOR SEE ELEVATIONS FOR
NUMBER OF DRAWERS NUMBER OF DRAWERS NUMBER OF DRAWERS NUMBER OF DRAWERS Not published - All rights reserved.
BASE CABINET BASE CABINET BASE CABINET BASE CABINET
CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4"
WHITE MELAMINE INTERIOR WHITE MELAMINE INTERIOR WHITE MELAMINE INTERIOR WHITE MELAMINE INTERIOR
AND PLASTIC LAMINATE AND PLASTIC LAMINATE AND PLASTIC LAMINATE AND PLASTIC LAMINATE
4"

4"

4"

4"
VENEER EXTERIOR ON ALL VENEER EXTERIOR ON ALL VENEER EXTERIOR ON ALL VENEER EXTERIOR ON ALL
3" 1' - 9" EXPOSED SIDES 3" 1' - 9" EXPOSED SIDES 3" 1' - 9" EXPOSED SIDES 3" 1' - 9" EXPOSED SIDES
2' - 0" 2' - 0" 2' - 0" 2' - 0"

SECTION DETAIL - BASE CABINET W/ DRAWERS & UPPER SECTION DETAIL - BASE CABINET W/ DRAWERS & UPPER CABINET
5
A8-4
SECTION DETAIL - BASE CABINET W/ DRAWERS (BASE ONLY)
N.T.S.
6
A8-4
SHELVING
N.T.S. A8-4
7 W/ MICROWAVE SHELF
N.T.S.
8
A8-4
SECTION DETAIL - BASE CABINET W/ DRAWERS & UPPER CABINET
N.T.S.

1 09/07/2018 ISSUED FOR BID


1'-0" No. Date Issue

Project Number 15849


SCHEDULED CEILING
Drawn S. DENNY
VARIES

VARIES

VARIES

Checked K. BOYER
1' - 0" 1' - 0"
PLAM CLOSURE PANEL Proj. Arch./Eng. K. SCHUSTER
WOOD BLOCKING AS REQUIRED, TYP.

METAL SHELF SUPPORTS


(2) 3/4" BLACK MELAMINE
ADJUSTABLE SHELVES 3/4" REVEAL 3/4" REVEAL
2' - 6"

WALL MOUNTED CABINET


Provident Hospital - Renal
CONSTRUCTED OF 3/4" WHITE
MELAMINE INTERIOR AND PLASTIC HOOKS AT BACK AND Dialysis Center
LAMINATE VENEER EXTERIOR ON SIDES OF LOCKER
ALL EXPOSED SIDES

GPDW SURFACE LOCK LOCK, (TYP.)


2'-1"
SCHEDULED PARTITION SCHEDULED PARTITION SCHEDULED COUNTERTOP -
LOW PROFILE UNDER CABINET
5' - 6 1/8"

LIGHT WHERE INDICATED; SEE RCP PROVIDE BACKSPLASH/SIDESPLASH


LOCKERS CONSTRUCTED OF 3/4" LOCKERS CONSTRUCTED OF 3/4"
5' - 8"

5' - 8"

WHERE THE COUNTER IS IN


6' - 0"

6' - 0"

GPDW SURFACE WHITE MELAMINE INTERIOR AND WHITE MELAMINE INTERIOR AND

4"
CONTACT W/ ADJACENT WALL
PLASTIC LAMINATE VENEER PLASTIC LAMINATE VENEER
EXTERIOR ON ALL EXPOSED EXTERIOR ON ALL EXPOSED

5"
ADA COMPLIANT DROP-IN SINK
SIDES SIDES W/ REAR DRAIN OUTLET

8"
4' - 6"

HOOKS AT BACK AND SIDE PANEL WHERE COUNTER IS


SIDES OF LOCKER NOT IN CONTACT W/ ADJACENT WALL 430 East 51st Place
Chicago, Illinois 60615

2' - 10"
GPDW SURFACE
LOCK LOCK, (TYP.)

Project Name

TYPICAL CASEWORK DETAILS


4"

4"

4" 4"

9
A8-4
SECTION DETAIL - UPPER CABINET
N.T.S.
10 SECTION DETAIL - DOUBLE LOCKERS
A8-4 N.T.S.
11 SECTION DETAIL - SMALL LOCKERS
A8-4 N.T.S.
12 SECTION DETAIL - ADA SINK
A8-4 N.T.S.
Sheet Name

Drawing No. A8-4


1'' MIN.
PLAM FACED SCRIBE
CUT TO FIT

FACE OF WALL

TRACK BACKING AT TOP, SEE


PLAN AT CABINET SCRIBE BACKING TYPE DETAILS
A
COUNTERTOP. SEE SCREWS @ 12'' O.C., AND SCREWS @ 16'' O.C., 2 PER
ELEVATION FOR MORE

VERIFY
WITHIN 3'' FROM ENDS BLOCKING MIN. AND 4'' FROM
INFORMATION END TYP. (OMIT IF CABINET
HAS INTEGRAL BASE)
Department of Capital Planning & Policy

SEE ELEVATIONS
2''X4'' WOOD BLOCKING, USE

7'-2'' MAX
CEILING AS
Bureau of Asset Management

HEIGHT
PRESSURE TREATED @ SLABS

FASCIA
3" ± SCHEDULED ON GRADE. LOCATE BLOCKING
PLAM FACED FILLER AT FRONT AND OPEN ENDS, OR

1"
3" TO BLOCKING AT 4'-0'' O.C.
Notice: This drawing has not been published and is the
HEAVY DUTY EPOXY CUT TO FIT
sole property of Cook County. It is loaned to the borrower

4"
COATED METAL SUPPORT GYPSUM SCREWS @ 16'' O.C., 4''
BRACKET MOUNT TO WALL BOARD FACE OF WALL FROM ENDS for their confidential use only. In consideration of the loan
STUDS, PAINT TO MATCH WALL FILLER CUT TO FIT WALL BASE; SEE ID SHEETS
of this drawing, the borrower promises and agrees to
SEE BASE CABINET ANCHORAGE
1" DETAIL "D" SHIM BY CABINET INSTALLER
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
PLAN AT CABINET FILLER directly or indirectly, nor used for any purpose other than
2
A8-5
SECTION DETAIL - COUNTERTOP CONCEALED SUPPORT BRACKET
1" = 1'-0"
B
C
FLOOR CABINET TALLER THAN 3'-0''
D
BASE CABINET ANCHORAGE
for which it is furnished, in whole or part.

3/4''=1'-0'' 1 1/2''=1'-0''
SECTION AT GYP BD SOFFIT / FASCIA
A

SEE ELEVATIONS
SCREWS @ 16'' O.C. W/ MIN. 1/2'' TRACK BACKING AT TOP, SEE
PENETRATION FRONT & BACK BACKING TYPE DETAILS

HEIGHT
FASCIA
CEILING AS TYP TOP & BOTTOM SCREWS @ 12'' O.C., AND
SCHEDULED WITHIN 3'' FROM ENDS, TYP TOP
SCREWS @ 16'' O.C. & BOTTOM
SCRIBE AS REQD

2'' MIN.
BACKING PLATE, BACKING PLATE AT BOTTOM,
FASCIA MATERIAL SEE BACKING TYPE DETAILS SEE BACKING TYPE DETAILS
2' - 0" TYP U.N.O. 1" TO MATCH CABINET
SIDE & BACK SPLASH AT CONTRACTOR'S OPTION;
AS INDICATED ON 1" FACE
ON PLANS 1/2'' RADIUS U.N.O. BACKING PLATE W/ SCREWS
INTERIOR ELEVATIONS @ 16'' O.C. MAY BE SUBSTITUTED FOR
FLOOR CABINET CONNECTION
PLAM FACED FILLER
4"

CUT TO FIT SEE BASE CABINET ANCHORAGE


SEE INTERIOR
1 1/2"

SEALANT SECTION AT PLAM SOFFIT / FASCIA DETAIL "D"


ELEVATIONS

FACE OF WALL
SUPPORT FRAME AS 1"
B
REQUIRED 2' - 0" BASE CABINET DEPTH U.N.O.
2'' MIN. BASE CABINET UPPER CABINET
A 3/4''=1'-0''
B 3/4''=1'-0''
PLAN AT CABINET FILLER - INSIDE CORNER
C

1
A8-5
SECTION DETAIL - TYPICAL COUNTERTOP INFORMATION
1" = 1'-0"
3
A8-5
SOFFIT / FASCIA TYPES
3/4" = 1'-0"
4
A8-5
CABINET SCRIBE/ FILLER DETAILS
3/4" = 1'-0" A8-5
5 SECTION DETAIL - TYPICAL CABINET ANCHORAGE
3/4" = 1'-0"

POST SPACING TO BE CONFRIMED WITH


DENTAL SUPPLIER - 16" OC MAX
REQD BY ITEM
1'-4'' U.N.O. OR

3/4'' X 8'' X STUD SPACING


18 GA 1 1/4' X 1 1/4'' X 8'' SECTION FIRE RETARDANT TREATED PLYWOOD
METAL CLIP ANGLE 18 GA 1 1/4' X 1 1/4'' X 8''
METAL CLIP ANGLE

PLAN
VERIFY DIM

3/4'' X 8'' X STUD SPACING 4" X 4" 16" OC POST FOR DENTAL X-RAY ARM
TO FLOOR

FIRE RETARDANT TREATED MOUNTING - SUPPORT LOAD OF 1,500 LBS OFF


PLYWOOD CENTER. COORDINATE WITH MFG SPECS Holabird & Root, LLC expressly disclaims any
PLAN VIEW SECTION VIEW
responsibility arising from any unauthorized use of these
E WOOD PLATE / BLOCKING & BACKING plans, drawings and notes. Any authorization must be in
A PLATE / WOOD BACKING PLAN VIEW (SEE A FOR SIMILAR SECTION) writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
14 GA FABRICATED
FLUSH MOUNT
BACKING OPA-# Not published - All rights reserved.
0192

1/2'' MIN (4) #10 SMS TYP.


1'' MAX
METAL STUD:
3 5/8'' X 20 GA MIN
@ 16'' O.C., TYP.
6'' X 16 GA BACKING PLATE FASTEN TO STUDS W/ (3) # 6'' X 16 GA TRACK NOTCH AND FASTEN TO STUDS W/ (3) # 1. THIS BACKING IS FOR GRAB BARS AND EXTRA HEAVY SEE NOTES UNDER A FOR BACKING NOTES
10 X 3/4'' WAFER HEAD SELF DRILLING SCREWS PER 10 X 3/4'' WAFER HEAD SELF DRILLING SCREWS PER EQUIPMENT
STUD. ALL BACKING TO SPAN MIN OF (3) STUDS. STUD. ALL BACKING TO SPAN MIN OF (3) STUDS. 2. SEE BACKING PLATE TYPE B FOR ADDITIONAL NOTES
BACKING PLATE TO BE Fy=50 KSI STEEL BACKING TRACK TO BE Fy=50 KSI STEEL 1 09/07/2018 ISSUED FOR BID
ALTERNATE: PLYWOOD SIZED FOR LOAD
No. Date Issue
A PLATE BACKING: USE FOR FOLLOWING ITEMS B TRACK BACKING: USE FOR FOLLOWING ITEMS C ALTERNATE TO B E 4X4 POST: USE FOR FOLLOWING ITEMS
1. FLOOR MOUNTED BASE CABINETS 1. HANDRAILS AND GRAB BARS 1. LARGE MONITOR DISPLAYS
2. WALL MOUNTED DISPENSERS AND HARDWARE 2. FLOOR MOUNTED CABINETS GREATER THAN 1/2"
WEIGHING LESS THAN 40 LBS 3'-0'' IN HEIGHT 16 GA TRACK MAY BE SUBSTITUTED FOR
3. MIRRORS 3. WALL HUNG CABINETS GREATER THAN 15'' IN 1 1/4'' FLANGE W/O STIFFENER LIP AS Project Number 15849
4. BACKING AT THE BOTTOM OF WALL HUNG DEPTH AND AT THE TOP OF WALL HUNG SHOWN W/ THE FOLLOWING LIMITATIONS:
1/2"

CABINETS LESS THAN 15'' IN DEPTH CABINETS LESS THAN 15'' IN DEPTH 1. STUD SPACING IS 16'' O.C. OR LESS Drawn S. DENNY
6"

5. WALL PROTECTION: UPPER / LOWER CRASH 2. FOR 200 LBS LOADS MAX
RAILS, CHAIR RAILS 3. USE 14 GA TRACK AS SHOWN FOR
6. WHEN BACKING USED FOR ITEMS WEIGHING 20 GRAB BAR LOADS EQUAL TO 250 LBS Checked K. BOYER
LBS OR LESS, BACKING WILL NEED ONL ATTACH Fy=50KSI STEEL
TO TWO STUDS. THIS DOES NOT APPLY TO Proj. Arch./Eng. K. SCHUSTER
HANDRAILS AND GRAB BARS
D ALTERNATE TO B

6
A8-5
TYPICAL BACKING DETAILS
1 1/2" = 1'-0"
Provident Hospital - Renal
Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

TYPICAL CASEWORK DETAILS

Sheet Name

Drawing No. A8-5


1' - 8"
V.I.F.

EXISTING CMU HEADER

1/2" ALUM. REVEAL BOTH SIDES

1 1/2"
SOLID SURFACE FRAME 1' - 4"
5" 1"
GROMMET SOLID SURFACE
BUTT GLAZED GLASS 1' - 0"
ACCESS COUNTERTOP BEYOND
EXISTING CMU

/2"
DOOR

11
COLUMN ENCLOSURE FINISHED WALL BEYOND

1 1/4"
1/2" REVEAL BOTH SIDES CONTINUOUS SOLID SURFACE
STAINLESS COUNTERTOP WITH
Department of Capital Planning & Policy
GPDW WALL BELOW STEEL HINGE EASED EDGE Bureau of Asset Management
Notice: This drawing has not been published and is the

1' - 0 3/4"
VOICE HOLE GROMMET - COORDINATE

3" Ø
sole property of Cook County. It is loaned to the borrower

1' - 10 1/2"
SOLID SURFACE W/ OUTLET LOCATIONS
COUNTERTOP 1/2" REVEAL SS1 for their confidential use only. In consideration of the loan
CABLE/ELECTRICAL of this drawing, the borrower promises and agrees to
RACEWAY AS REQUIRED - SS1
return it upon request and agrees that it shall not be
COORDINATE W/ELECTRICAL reproduced, copied, loaned, or otherwise disposed of
TRANSACTION OPENING 4"x12" directly or indirectly, nor used for any purpose other than
2 POWER/DATA OUTLET
for which it is furnished, in whole or part.

4' - 4"

4"
A8-6 SOLID SURFACE COUNTERTOP SCHEDULED SUPPORT
BACKPOST SUPPORT

1 1/2"

3' - 4"
2" 1/2" ALUM. REVEAL BOTH SIDES AS REQUIRED
CABLE/ELECTRICAL RACEWAY REMOVEABLE
BUTT GLAZED GLASS DIALYSIS BOX
ACCESS PANEL
BACKPOST SUPPORT AS REQUIRED

2' - 6"
1 1/2"
SOLID SURFACE
COUNTERTOP POWER/DATA OUTLET WP2
GPDW ON

1' - 6 1/2"
LAMINATE PANEL

2' - 6"
3 5/8" STUDS
GPDW WALL
GPDW GPDW ON PL1
BELOW
2 1/2" STUDS
GPDW PARTITION WALL BASE
WALL BASE
1/2" REVEAL
BOTH SIDES
1' - 0" 1' - 7"
SOLID SURFACE
FRAME

1
A8-6
PLAN AT RECEPTION DESK
1" = 1'-0" [REF: 1/ A8-1]
2
A8-6
SECTION AT RECEPTION DESK
1 1/2" = 1'-0" [REF: 24/ A8-2]
3
A8-6
SECTION DETAIL - DIALYSIS BOX
1 1/2" = 1'-0" [REF: 4/ A8-1]
4
A8-6
NURSE WORK STATION @ PLAM PANEL
1 1/2" = 1'-0" [REF: 2/ A8-1]

BUTT GLAZED GLASS


BUTT GLAZED GLASS SPLASH GUARD
SPLASH GUARD
SS1 3/4" TYP. SOLID
SOLID
SURFACE CAP
SURFACE CAP
3/4"

1/2" REVEAL
1 1/4"

BOTH SIDES
1/2" REVEAL
BOTH SIDES
GROMMET -
GROMMET - COORDINATE WITH
1' - 2"

1' - 2"
COORDINATE WITH OUTLET LOCATIONS
OUTLET LOCATIONS
SS1

1 1/2"
1 1/2"

POWER/DATA OUTLET POWER/DATA OUTLET

CONCEAL 1 1/2" x CONCEAL 1 1/2" x


1 1/2" x 3/8" STEEL 1 1/2" x 3/8" STEEL
BRACKET BRACKET 1'-6" Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
PLAM PANEL BEYOND plans, drawings and notes. Any authorization must be in
1'-1 1/2"

writing.

This drawing copy may have been reproduced at a size


PL1 different than originally drawn. The Owner and Architect
2' - 6"

2' - 6"
assume no responsibility for use of incorrect scale.
GPDW ON 3 GPDW ON 3 Drawings are not to be scaled.
5/8" STUDS 5/8" STUDS
Not published - All rights reserved.
WALL BASE, TYP. WALL BASE, TYP.

5
A8-6
NURSE WORK STATION @ PARTIAL WALL
1 1/2" = 1'-0" [REF: 2/ A8-1]
6
A8-6
NURSE WORK STATION @ CURTAIN WALL
1 1/2" = 1'-0" [REF: 2/ A8-1]

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

CASEWORK DETAILS

Sheet Name

Drawing No. A8-6


GENERAL NOTES: ROOM & BUILDING IDENTIFICATION SIGNAGE SIGNAGE TYPE SCHEDULE
PLAN ROOM SIGN SIGN
TYPE 1: TYPE 2: 1. SEE CBC 2017 AND NFPA 2012 FOR ALL CODE COMPLIANT SIGNAGE REQUIREMENTS; EMERGENCY PLAN SIGNAGE, ETC. PLAN ROOM NAME NUMBER SIGN NAME NUMBER TYPE PLACMENT LOCATION
NUMBER ONLY SIGN W/ ROOM NAME & NUMBER TREATMENT AREA 1 1 9 WALL ABOVE COORESPONDING
2. ROOM SIGNAGE BASIS OF DESIGN IS POBLOCKI SIGN COMPANY. SIGNAGE TYPES SHOWN ON A8-7 ARE FOR REFERENCE ONLY. TREATMENT CHAIR
TREATMENT AREA 2 2 9 WALL ABOVE COORESPONDING
3. SIGNAGE TO BE MOUNTED AS SHOWN ON A6-1, UNO. TREATMENT CHAIR
TREATMENT AREA 3 3 9 WALL ABOVE COORESPONDING
4. ALL SIGNAGE TO COMPLY WITH ACCESSIBLE GUIDELINES ANSI 117.1 FOR VISUAL CHARACTERS, RAISED CHARACTERS, BRAILLE TREATMENT CHAIR
AND INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY.
TREATMENT AREA 4 4 9 WALL ABOVE COORESPONDING
5. ALL ROOMS TO RECEIVE SIGNAGE WILL BE CONFIRMED IN SHOP DRAWINGS. TREATMENT CHAIR
TREATMENT AREA 5 5 9 WALL ABOVE COORESPONDING
6. PROVIDE SIGN NAME "RECEIVING" AT EXTERIOR DOOR 100D. TREATMENT CHAIR
TREATMENT AREA 6 6 9 WALL ABOVE COORESPONDING
7. PROVIDE OCCUPANCY CAPACITY SIGNS AT ALL WAITING AREAS AND CONFERENCE ROOMS. TREATMENT CHAIR Department of Capital Planning & Policy
TREATMENT AREA 7 7 9 WALL ABOVE COORESPONDING Bureau of Asset Management
8. PROVIDE (3) EVACUATION PLANS: ARCHITECT TO PROVIDE FLOOR PLAN GRAPHIC FOR THE EVACUATION PLANS. LOCATIONS TREATMENT CHAIR
SHALL BE CONFIRMED IN SHOP DRAWINGS. Notice: This drawing has not been published and is the
PRIVATE PAT./ISOLATION 8 ISOLATION ROOM 8 2 & 2.1 ADHERED TO GLASS WALL
sole property of Cook County. It is loaned to the borrower
TREATMENT AREA 9 9 9 WALL ABOVE COORESPONDING
TYPE 2.1: 9. PROVIDE SIGNAGE FOR FIRE DEPARTMENT CONNECTION LOCATION IN VESTIBULE.
TREATMENT CHAIR
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
INSERT PANEL WINDOW 10. SIGN TYPES ARE FOR REFERENCE ONLY. ALL SIGNAGE SHALL BE APPROVED BY THE OWNER. THE FINAL TEXT (ENGLISH & TREATMENT AREA 10 10 9 WALL ABOVE COORESPONDING return it upon request and agrees that it shall not be
SPANISH) SHOULD BE REVIEWED WITH THE OWNER PRIOR TO RELEASE FOR FABRICATION. TREATMENT CHAIR reproduced, copied, loaned, or otherwise disposed of
TREATMENT AREA 11 11 9 WALL ABOVE COORESPONDING directly or indirectly, nor used for any purpose other than
14. PERMANENT ROOM SIGNS ARE TO BE LOCATED AT DOORWAYS, U.N.O. TREATMENT CHAIR for which it is furnished, in whole or part.
TREATMENT AREA 12 12 9 WALL ABOVE COORESPONDING
15. SIGNS CAN MOUNT TO THE DOOR ITSELF IF:
TREATMENT CHAIR
A. THE SIGN IS MOUNTED ON THE PUSH SIDE OF THE DOOR (IT SWINGS INWARD).
B. THE DOOR AUTOMATICALLY CLOSES. VESTIBULE 100A -
C. THE DOOR HAS NO HOLD OPEN DEVICES. CORRIDOR 100B -
CORRIDOR 100C -
CORRIDOR 100D -
WAITING ROOM 101 OCCUPANCY CAPACITY
CONFERENCE 102 CONFERENCE ROOM 2 ADHERED TO GLASS WALL
DIETITIAN 103 DIETITIAN 2 PUSH SIDE OF DOOR
SOCIAL WORKER 104 SOCIAL WORKER 2 PUSH SIDE OF DOOR
RECEPTION 105 -
EXAM 106 EXAM ROOM 2 PUSH SIDE OF DOOR
WOMENS 107 WOMEN 6 PUSH SIDE OF DOOR
MENS 108 MEN 6 PUSH SIDE OF DOOR
OFFICE 109 OFFICE 2 PUSH SIDE OF DOOR
TYPE 3: TYPE 4: TYPE 5: TYPE 6: DIRECTOR OFFICE 110 DIRECTOR OFFICE 2 PUSH SIDE OF DOOR
SIGN W/ ROOM NAME & NUMBER LARGE SIGN W/ ROOM NAME & NUMBER TOILET ROOM SIGN TOILET ROOM SIGN TELECOM 111 TELECOM ROOM 2 PUSH SIDE OF DOOR
JANITOR'S CLOSET 112 JANITORS CLOSET 2 PUSH SIDE OF DOOR
STAFF 113 STAFF ROOM 2 PUSH SIDE OF DOOR
CHANGING ROOM 113A CHANGING ROOM 2 PUSH SIDE OF DOOR
STAFF TOILET 113B STAFF TOILET 6 PUSH SIDE OF DOOR
PAT. TOILET 114 PATIENT TOILET 5 PUSH SIDE OF DOOR
MED. PREP. 115 MEDICAL PREP 2 NEAREST ADJACENT WALL
TREATMENT AREA 116 TREATMENT AREA 4 NEAREST ADJACENT WALL @
CORRIDOR
NURSE STATION 116A -
W.C. 117A PATIENT TOILET 5 PUSH SIDE OF DOOR
SOILED STORAGE 118 SOILED STORAGE 2 PUSH SIDE OF DOOR
CLEAN SUPPLY 119 CLEAN SUPPLY 2 PUSH SIDE OF DOOR
EQUIP. REPAIR 120 EQUIPMENT REPAIR ROOM 2 PUSH SIDE OF DOOR
LAB 121 LAB 2 PUSH SIDE OF DOOR
STORAGE 122 STORAGE 2 PUSH SIDE OF DOOR
ELECTRICAL 123 ELECTRICAL ROOM 2 PUSH SIDE OF DOOR
MECHANICAL 124 MECHANICAL ROOM 2 PUSH SIDE OF DOOR
WATER TREATMENT 125 WATER TREATMENT ROOM 2 PUSH SIDE OF DOOR

Holabird & Root, LLC expressly disclaims any


responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.

TYPE 7:
REGULATORY/ADVISORY VINYL ON ENTRY GLASS

TYPE 8: TYPE 9:
TACTILE EXIT SIGN OPEN EXAM SIGN

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

BUILDING SIGNAGE

Sheet Name

Drawing No. A8-7


SUSPENDED GRID W/ REVEAL,
TYP.

CEILING SUSPENSION TIE ROD


TO UNDERSIDE OF SUPPORT
FRAME, TYP.
ACOUSTICAL CEILING TILE

CEILING
SEE RCP
CEILING SUSPENSION TIE ROD
1/2" ALUM SHADOW MOLDING TRIM TO UNDERSIDE OF SUPPORT
SUSPENDED GRID W/ REVEAL, FRAME
CEILING SUSPENSION TIE ROD 2" 5/8" GPDW ON 3 5/8" MTL STUD
TYP.
SUSPENDED GRID W/ REVEAL TO UNDERSIDE OF SUPPORT
LATERAL BRACING FRAME, TYP. CEILING SUSPENSION Department of Capital Planning & Policy

6" MIN.
ACOUSTICAL CEILING TILE
SUSPENDED GRID W/ REVEAL, TYP. SUSPENDED GRID W/ REVEAL, TYP. TIE ROD TO UNDERSIDE
Bureau of Asset Management

6" MIN
OF SUPPORT FRAME

6" MIN
FOR ELEVATIONS
CEILING Notice: This drawing has not been published and is the
SEE PLAN

SEE RCP SUSPENDED GRID W/ REVEAL sole property of Cook County. It is loaned to the borrower
CEILING RECESSED COVE
SEE RCP CEILING SUSPENSION TIE ROD CEILING
LIGHT. PROVIDE for their confidential use only. In consideration of the loan
TO UNDERSIDE OF SUPPORT FRAME SEE RCP ACOUSTICAL CEILING TILE of this drawing, the borrower promises and agrees to
ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE BLOCKING AS NEEDED.
1/2” DRYWALL TO ACOUSTICAL return it upon request and agrees that it shall not be

6"
1/2" ALUM SHADOW
1/2" ALUM SHADOW MOLDING TRIM CEILING SHADOW REVEAL MOLDING TRIM 1/2" ALUM SHADOW MOLDING TRIM
CEILING reproduced, copied, loaned, or otherwise disposed of
CEILING SEE RCP
SUSPENDED GRID W/ REVEAL directly or indirectly, nor used for any purpose other than
SEE RCP ALIGN SOFFIT FACE WITH WALL
ACOUSTICAL CEILING TILE
5/8" GPDW ON 3 5/8" for which it is furnished, in whole or part.
5/8" GPDW ON 3 5/8" MTL STUD MTL STUD 2' - 0"
ACOUSTICAL CEILING TILE DRYWALL CEILING

6" MIN.
5/8" GPDW ON 3 5/8" MTL STUD
1/2" ALUM SHADOW MOLDING TRIM RECESSED DOWNLIGHT
CEILING
SEE RCP CEILING
ALIGN SOFFIT FACE WITH WALL
SEE RCP
DRYWALL CEILING 1' - 10" ALIGN SOFFIT FACE CORRIDOR 100E DENTAL EXAM
WITH WALL

TREATMENT AREA NURSE'S STATION

1
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
2
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
3
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
4
A9-1
CEILING DETAIL - RECESSED COVE LIGHT
1 1/2" = 1'-0" [REF: 1/ A3-1]

SUSPENDED GRID W/
REVEAL, TYP.

CEILING SUSPENSION TIE ROD


TO UNDERSIDE OF SUPPORT
FRAME
6" MIN

CEILING
SEE RCP

ACOUSTICAL CEILING TILE

1/2" ALUM SHADOW


MOLDING TRIM SOFFIT DIFFUSER, SEE
MECHANICAL DRAWINGS
CEILING SUSPENSION
5/8" GPDW ON 3 5/8"
MTL STUD
TIE ROD TO UNDERSIDE
EXISTING STRUCTURE OF SUPPORT FRAME
CEILING SUSPENSION TIE ROD
TO UNDERSIDE OF SUPPORT FRAME CEILING
SEE RCP
RECESSED DOWNLIGHT EXISTING FASCIA

6"
LAY IN CEILING
Holabird & Root, LLC expressly disclaims any
WINDOW ROLLER SHADE
CEILING responsibility arising from any unauthorized use of these
SEE RCP
plans, drawings and notes. Any authorization must be in
CEILING
SEE RCP NEW GBDW SOFFIT ON 2 1/2" FRAMING writing.
EXISTING STOREFRONT
ALIGN SOFFIT FACE 1' - 6"
WITH WALL
This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
DRYWALL CEILING assume no responsibility for use of incorrect scale.
1/2" ALUM SHADOW MOLDING TRIM Drawings are not to be scaled.

Not published - All rights reserved.

5
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
6
A9-1
Section 4
1 1/2" = 1'-0" [REF: 1/ A3-1]

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

INTERIOR DETAILS

Sheet Name

Drawing No. A9-1


GENERAL NOTES: DEMOLITION PLANS
1. FIELD VERIFY ALL EXISTING CONDITIONS. SCOPE OF THE
DEMOLITION WORK SHALL BE AS SHOWN ON THE DRAWINGS
INCLUDING BUT NOT LIMITED TO THE FOLLOWING : PORTIONS OF
EXISTING WALLS, FLOOR AND WALL FINISHES, DOORS,
CEILINGS, LIGHTING, PLUMBING, DUCT WORK, EQUIP., CONDUIT,
CABLE TRAYS, WIRING AND SELECT FLOORING TO SUBSTRATE.
1 2 3 REMOVE ALL CASEWORK AND EQUIPMENT AND ALL MOUNTED
10" ACCESSORIES.

9" WOMENS MEN'S MEN'S 2. TO THE BEST OF ARCHITECT'S KNOWLEDGE, ALL ELEMENTS
PUBLIC TOILET PUBLIC TOILET STAFF TOILET IDENTIFIED FOR DEMOLITION ARE NON-LOAD BEARING. ALL
BEARING ELEMENTS ARE TO REMAIN UNLESS NOTED
OTHERWISE. CONTACT ARCHITECT IF THERE IS A CONCERN
A A OVER WHETHER AN ELEMENT IS LOAD BEARING OR NOT. DO
024119.02
WOMEN'S SUPERVISORS DIRECTOR NOT PROCEED UNTIL ARCHITECT EVALUATES ELEMENT IN Department of Capital Planning & Policy
STAFF LOUNGE STAFF TOILET 024119.02
AND LOCKERS
QUESTION. ALL BEARING ELEMENTS NOT TO BE REMOVED ARE Bureau of Asset Management
024119.09 TO BE PROTECTED.
024119.01 024119.02 Notice: This drawing has not been published and is the
3. ALL COLUMNS, BEAMS, FLOOR/CEILING JOISTS TO REMAIN, sole property of Cook County. It is loaned to the borrower
U.N.O. for their confidential use only. In consideration of the loan
024119.03 of this drawing, the borrower promises and agrees to
024119.15 024119.01 024119.01
VESTIBULE 024119.09 024119.08 024119.02
024119.06
024119.02 4. ALL WORK TO BE DONE IN ACCORDANCE WITH APPLICABLE return it upon request and agrees that it shall not be
024119.01 JANITOR'S reproduced, copied, loaned, or otherwise disposed of
024119.09 024119.03
BUILDING CODES AND ALL OTHER CODES THAT HAVE
024119.10 024119.02 CLOSET AUTHORITY OVER THIS PROJECT. SECURE REQUIRED PERMITS. directly or indirectly, nor used for any purpose other than
024119.06
PROVIDE ALL NECESSARY SAFEGUARDS, BARRIERS, for which it is furnished, in whole or part.
B B TEMPORARY POWER, LIGHTING, FIRE PROTECTION, ETC. AS
024119.03
024119.07 REQUIRED DURING DEMOLITION.
024119.15 024119.05 024119.06
5. COORDINATE NEW OPENINGS WITH MECH. LOCATIONS & SIZES.
024119.03
WAITING AREA REFER TO MECH. DOCUMENTS FOR ADDITIONAL OPENINGS.
024119.06 024119.02
024119.08 024119.05 STORAGE 6. CONTRACTOR SHALL EXERCISE CARE TO AVOID DAMAGE TO
024119.10 ENTRY EXISTING WORK, ADJACENT SURFACES AND ADJOINING AREAS
024119.01 INCLUDING BUT NOT LIMITED TO THE PORTION OF THE WORK
024119.02 PHARMACY THAT IS TO REMAIN AS PART OF THE COMPLETED
024119.04 CONSTRUCTION, CONTRACTOR SHALL BE REQUIRED TO REPAIR
024119.02
OR OTHERWISE RESTORE ANY SUCH AREAS OR SURFACES THAT
BECOME DAMAGED OR REMOVED ON ACCOUNT OF THE
C 024119.14 024119.03
C DEMOLITION WORK.
024119.06
7. DEMOLITION SHALL BE PERFORMED IN AN ORDERLY SEQUENCE
024119.10
024119.03 024119.02
SCHEDULED BY THE CONTRACTOR AND COORDINATED WITH
VESTIBULE 024119.06 THE OWNER.
024119.02 024119.01
024119.09 WAITING AREA 024119.08
8. CONTRACTOR SHALL BE REQUIRED TO LEGALLY DISPOSE OF
024119.14 024119.01 ANY SALVAGED ITEMS THAT OWNER DOES NOT REQUIRE.

024119.15 024119.02 PATIENT 024119.02 TELEPHONE ELECTRICAL MECHANICAL 9. THE ARCHITECT HAS NO KNOWLEDGE OF AND SHALL NOT BE
ADVOCATE ROOM ROOM ROOM HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDDOUS
024119.16
MATERIALS ON JOB SITE. THE CONTRACTOR SHALL
IMMEDIATELY ISOLATE THE AFFECTED IF ASBESTOS OR OTHER
D D HAZARDOUS MATERIALS ARE DISCOVERED DURING
CONSTRUCTION. NOTIFY OWNER FOR FURTHER INSTRUCTION
BEFORE PROCEEDING.

024119.18
10. COORDINATE/VERIFY WITH THE OWNER ALL FURNITURE &
1 2 3 CASEWORK TO BE SALVAGED PRIOR TO DEMOLITON.

11. SCHEDULE ALL SERVICE SHUT DOWNS WITH OWNER.

1 100 LEVEL DEMOLITION PLAN


DA2-1 1/8" = 1'-0"
12. THE ARCHITECTURAL DEMOLITION DRAWING INDICATES THE
CONSTRUCTION TO BE REMOVED, BUT NOT NECESSARILY THE
EXACT QUANTITY,, TYPE OF MATERIAL, OR EXTENT OF
DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
VISITING THE SITE, VERIFYING EXISTING CONDITIONS, AND
REFERRING TO ALL CONSTRUCTION DOCUMENTS FOR
SPECIFICS RELATED TO THESE ITEMS.

13. SEE PLUMBING DRAWINGS FOR EXTENT OF FLOOR TRENCHING


FOR NEW PLUMBING LINES.
Holabird & Root, LLC expressly disclaims any
14. SEE MEP DRAWINGS FOR EXTENT OF MEP DEMOLITION. responsibility arising from any unauthorized use of these
1 2 3 plans, drawings and notes. Any authorization must be in
15. CONTRACTOR SHALL ANTICIPATE AND MAKE ANY AND ALL writing.
ARRANGEMENT WITH LOCAL GOVERNMENT AGENCIES SHOULD
ENTRY ONTO OR OBSTRUCTION OF A PUBLIC WAY BE This drawing copy may have been reproduced at a size
NECESSARY IN CONNECTION WITH THE WORK. different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
16. PROVIDE AND MAINTAIN SHORING, BRACING, AND STRUCTURAL Drawings are not to be scaled.
A A SUPPORTS AS REQUIRED TO PRESERVE STABILITY AND
PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OR Not published - All rights reserved.
024119.11
CONSTRUCTION OR FINISHES THAT ARE TO REMAIN, PREVENT
024119.11 024119.11
024119.11 024119.11 024119.11 024119.11 UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF
024119.13 CONSTRUCTION BEING DEMOLISHED.
024119.12 024119.12 024119.11

024119.12
SYMBOLS: DEMOLITION PLANS
024119.13

024119.12 EXISTING WALL TO REMAIN

B B DEMO DOOR

DEMO WALL
024119.12 DEMO/TRENCH/EXCAVATE SLAB/ASPHALT AS
1 09/07/2018 ISSUED FOR BID
REQUIRED FOR SCOPE; DRAWING MAY NOT
024119.13 024119.11 SHOW ALL REQUIRED TRENCHING / No. Date Issue
EXCAVATION; COORDINATE EXTENT WITH
024119.12
ALL TRADES
Project Number 15849
024119.11 KEYNOTES: DEMOLITION PLANS
TUNNELING BELOW EXISTING SLAB Drawn S. DENNY
C C Key Value Keynote Text
024119.12 Checked K. BOYER

024119.13 024119.01 REMOVE HM FRAMES & WOOD DOORS Proj. Arch./Eng. K. SCHUSTER
024119.12 024119.02 REMOVE METAL STUD AND GBDW WALLS
024119.03 REMOVE STEEL SHUTTERS & ASSOCIATED
FRAMES & MOTORS
024119.04 REMOVE CMU FOR NEW DOOR
024119.05 REMOVE ACT FLOORING Provident Hospital - Renal
024119.11
024119.13 024119.06 REMOVE MILLWORK COUNTERTOPS Dialysis Center
024119.07 REMOVE DOOR & FRAME
024119.08 REMOVE FIXED SEATING
D D
024119.09 REMOVE VESTIBULE STOREFRONT
024119.10 REMOVE CONC & WOOD PLANTER/SEAT WALL
024119.11 REMOVE SUSPENDED ACT CEILING
024119.12 REMOVE GBDW SOFFIT
1 2 3 024119.13 REMOVE PLASTER CEILING
024119.14 REMOVE AND REPLACE ENTRY DOORS
024119.15 NEW DUCT WORK OPENINGS IN CMU

2 100 LEVEL DEMO REFLECTED CEILING PLAN


DA2-1 1/8" = 1'-0"
BULKHEAD. SEE MECHANICAL DRAWINGS. USE
EXISTING OPENINGS WHERE POSSIBLE.
PROVIDE NEW LINTELS WHERE NECESSARY.
430 East 51st Place
Chicago, Illinois 60615

024119.16 REMOVE DOOR WHILE LEAVING FRAME INTACT.


024119.18 REMOVE EXISTING BOLLARD IN CONFLICT WITH Project Name
NEW GENERATOR ENCLOSURE.
100 LEVEL DEMOLITION PLAN
AND REFLECTED CEILING
DEMOLITION PLAN
Sheet Name

Drawing No. DA2-1


GENERAL NOTES: DEMOLITION PLANS
1. FIELD VERIFY ALL EXISTING CONDITIONS. SCOPE OF THE
DEMOLITION WORK SHALL BE AS SHOWN ON THE DRAWINGS
INCLUDING BUT NOT LIMITED TO THE FOLLOWING : PORTIONS OF
EXISTING WALLS, FLOOR AND WALL FINISHES, DOORS,
CEILINGS, LIGHTING, PLUMBING, DUCT WORK, EQUIP., CONDUIT,
CABLE TRAYS, WIRING AND SELECT FLOORING TO SUBSTRATE.
REMOVE ALL CASEWORK AND EQUIPMENT AND ALL MOUNTED
ACCESSORIES.

2. TO THE BEST OF ARCHITECT'S KNOWLEDGE, ALL ELEMENTS


IDENTIFIED FOR DEMOLITION ARE NON-LOAD BEARING. ALL
BEARING ELEMENTS ARE TO REMAIN UNLESS NOTED
OTHERWISE. CONTACT ARCHITECT IF THERE IS A CONCERN
OVER WHETHER AN ELEMENT IS LOAD BEARING OR NOT. DO
NOT PROCEED UNTIL ARCHITECT EVALUATES ELEMENT IN Department of Capital Planning & Policy
QUESTION. ALL BEARING ELEMENTS NOT TO BE REMOVED ARE Bureau of Asset Management
TO BE PROTECTED.
Notice: This drawing has not been published and is the
3. ALL COLUMNS, BEAMS, FLOOR/CEILING JOISTS TO REMAIN, sole property of Cook County. It is loaned to the borrower
U.N.O. for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
4. ALL WORK TO BE DONE IN ACCORDANCE WITH APPLICABLE return it upon request and agrees that it shall not be
BUILDING CODES AND ALL OTHER CODES THAT HAVE reproduced, copied, loaned, or otherwise disposed of
AUTHORITY OVER THIS PROJECT. SECURE REQUIRED PERMITS. directly or indirectly, nor used for any purpose other than
1 2 3 PROVIDE ALL NECESSARY SAFEGUARDS, BARRIERS, for which it is furnished, in whole or part.
TEMPORARY POWER, LIGHTING, FIRE PROTECTION, ETC. AS
REQUIRED DURING DEMOLITION.

5. COORDINATE NEW OPENINGS WITH MECH. LOCATIONS & SIZES.


REFER TO MECH. DOCUMENTS FOR ADDITIONAL OPENINGS.
A A 6. CONTRACTOR SHALL EXERCISE CARE TO AVOID DAMAGE TO
EXISTING WORK, ADJACENT SURFACES AND ADJOINING AREAS
INCLUDING BUT NOT LIMITED TO THE PORTION OF THE WORK
THAT IS TO REMAIN AS PART OF THE COMPLETED
CONSTRUCTION, CONTRACTOR SHALL BE REQUIRED TO REPAIR
OR OTHERWISE RESTORE ANY SUCH AREAS OR SURFACES THAT
BECOME DAMAGED OR REMOVED ON ACCOUNT OF THE
DEMOLITION WORK.

7. DEMOLITION SHALL BE PERFORMED IN AN ORDERLY SEQUENCE


SCHEDULED BY THE CONTRACTOR AND COORDINATED WITH
THE OWNER.
B B
8. CONTRACTOR SHALL BE REQUIRED TO LEGALLY DISPOSE OF
ANY SALVAGED ITEMS THAT OWNER DOES NOT REQUIRE.

9. THE ARCHITECT HAS NO KNOWLEDGE OF AND SHALL NOT BE


HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDDOUS
MATERIALS ON JOB SITE. THE CONTRACTOR SHALL
IMMEDIATELY ISOLATE THE AFFECTED IF ASBESTOS OR OTHER
HAZARDOUS MATERIALS ARE DISCOVERED DURING
CONSTRUCTION. NOTIFY OWNER FOR FURTHER INSTRUCTION
BEFORE PROCEEDING.

10. COORDINATE/VERIFY WITH THE OWNER ALL FURNITURE &


C C CASEWORK TO BE SALVAGED PRIOR TO DEMOLITON.

11. SCHEDULE ALL SERVICE SHUT DOWNS WITH OWNER.

12. THE ARCHITECTURAL DEMOLITION DRAWING INDICATES THE


CONSTRUCTION TO BE REMOVED, BUT NOT NECESSARILY THE
EXACT QUANTITY,, TYPE OF MATERIAL, OR EXTENT OF
DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
VISITING THE SITE, VERIFYING EXISTING CONDITIONS, AND
REFERRING TO ALL CONSTRUCTION DOCUMENTS FOR
SPECIFICS RELATED TO THESE ITEMS.

13. SEE PLUMBING DRAWINGS FOR EXTENT OF FLOOR TRENCHING


D D FOR NEW PLUMBING LINES.
Holabird & Root, LLC expressly disclaims any
COORDINATE LOCATION OF 14. SEE MEP DRAWINGS FOR EXTENT OF MEP DEMOLITION. responsibility arising from any unauthorized use of these
SUBSLAB CONDUITS WITH plans, drawings and notes. Any authorization must be in
EXISTING MEP COMPONENTS 15. CONTRACTOR SHALL ANTICIPATE AND MAKE ANY AND ALL writing.
1 2 3 ARRANGEMENT WITH LOCAL GOVERNMENT AGENCIES SHOULD
ENTRY ONTO OR OBSTRUCTION OF A PUBLIC WAY BE This drawing copy may have been reproduced at a size
NECESSARY IN CONNECTION WITH THE WORK. different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
16. PROVIDE AND MAINTAIN SHORING, BRACING, AND STRUCTURAL Drawings are not to be scaled.
SUPPORTS AS REQUIRED TO PRESERVE STABILITY AND
1 100 LEVEL TRENCHING AND SELECTIVE DEMOLITION PLAN
DA2-2 1/8" = 1'-0"
PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OR
CONSTRUCTION OR FINISHES THAT ARE TO REMAIN, PREVENT
Not published - All rights reserved.
UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF
CONSTRUCTION BEING DEMOLISHED.

SYMBOLS: DEMOLITION PLANS


EXISTING WALL TO REMAIN

DEMO DOOR

DEMO WALL

DEMO/TRENCH/EXCAVATE SLAB/ASPHALT AS
1 09/07/2018 ISSUED FOR BID
REQUIRED FOR SCOPE; DRAWING MAY NOT
SHOW ALL REQUIRED TRENCHING / No. Date Issue
EXCAVATION; COORDINATE EXTENT WITH
ALL TRADES
Project Number 15849

TUNNELING BELOW EXISTING SLAB Drawn S. DENNY


SAWCUT WIDTH 4" CONCRETE SLAB
COORDINATE WITH EXISTING
Checked K. BOYER
AS REQUIRED
EXTERIOR SLAB
12"
Proj. Arch./Eng. K. SCHUSTER
#3 @ 24" O.C. EACH WAY - ROUGHEN SURFACE AND APPLY
DOWEL INTO EXISTING
MIN. LAP BONDING AGENT PRIOR TO KEYNOTES LEGEND
PLACING CONCRETE
REF#

Provident Hospital - Renal


SELF-EXPANDING BUTYL
Dialysis Center
STRIP WATERSTOP -
CONTINUOUS AT EACH SIDE

VAPOR RETARDER
4' - 0"

MAX

COMPACTED STRUCTURAL FILL.


NOTE: DO NOT LEAVE VOIDS
UNDER EDGE OF EXISTING
SLAB AT CUT.
NEW PIPING
PIPE BEDDING MATERIAL
(SEE PLUMBING DRAWINGS
AND SPECIFICATIONS) 430 East 51st Place
Chicago, Illinois 60615

Project Name

NOTE:
SAWCUT CONTROL JOINTS IN NEW CONCRETE AS REQUIRED. 100 LEVEL TRENCHING PLAN
ALIGN NEW CONTROL JOINTS WITH EXISTING CONTROL JOINTS.

2 UTILITY TRENCH - SIM. AT EXTERIOR


DA2-2 1" = 1'-0"
Sheet Name

Drawing No. DA2-2


Department of Capital Planning & Policy
Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

1 2 3

DIRECTOR JANITOR'S STAFF CHANGING


TELECOM
WOMENS MENS OFFICE OFFICE CLOSET TOILET ROOM STAFF

A
TV-01
CONFERENCE CAV-01
MICRO-01

REFU-01

CASU-03 SOILED
ELEC-01
CORRIDOR MOVS-01 CORRIDOR STORAGE
PAT. TOILET NARC-01 MED. PREP.
DEAE-01
CLEAN WATER
TV-02 TV-01
REUN-01 REUN-01 EW-01 SUPPLY TREATMENT
CORRIDOR
B
WAITING WHEE-01 DRDU-06
ROOM
DRCL-01
DI-01 EW-01
TV-02
DI-01 x 11
TAEP-01 TVAR-01
EW-02 EQUIP.
NURSE
TV-01 STATION REPAIR
EW-01
LAB Holabird & Root, LLC expressly disclaims any
EXAM BINS-01 DRCL-01
responsibility arising from any unauthorized use of these
SCHT-01
EW-02 C plans, drawings and notes. Any authorization must be in
COPM-01 SCI-01
REUN-01
writing.

STORAGE This drawing copy may have been reproduced at a size


RECEPTION different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
DRCL-02 Drawings are not to be scaled.
DI-01 TVAR-01
Not published - All rights reserved.

VESTIBULE

D
SOCIAL TREATMENT PRIVATE ELECTRICAL MECHANICAL
DIETITIAN
WORKER AREA PAT./ISOLATION

EQUIPMENT SCHEDULE
Type Mark Description Count

1 100 LEVEL EQUIPMENT PLAN


FFE2-1 1/8" = 1'-0"
BINS-01 BIN, SHREDDING, SECURE 1
CASU-03 CART, PROCEDURE, RESUSCITATION 1
CAV-01 AV CABINET 1 1 09/07/2018 ISSUED FOR BID
COPM-01 COPIER, PRINTER, MULTIFUNCTION 1
No. Date Issue
DEAE-01 DEFIBRILLATOR, AED 1
DI-01 DIALYSIS MACHINE 15
DRCL-01 DIALYSIS RECLINER - NIC 12 15849
Project Number
DRCL-02 DIALYSIS BARIATRIC RECLINER - NIC 1
DRDU-06 DRUG DISPENSING UNIT 1 Drawn S. DENNY
ELEC-01 ELECTROCARDIOGRAPH 1 Checked K. BOYER
EW-01 EYE WASH 3
Proj. Arch./Eng. K. SCHUSTER
EW-02 EYE WASH, DRENCH HOSE 2
MICRO-01 MICROWAVE 1
MOVS-01 MONITOR, VITAL SIGNS 1
NARC-01 CABINET, STORAGE, CLINICAL, NARCOTICS 1
REFU-01 REFRIGERATOR FREEZER, UPRIGHT 1
Provident Hospital - Renal
REUN-01 REFRIGERATOR, UNDERCOUNTER 3
SCHT-01 SCALE, HEIGHT 1 Dialysis Center
SCI-01 SCALE, INTEGRATED 1
TAEP-01 EXAM TABLE POWE 1
TV-01 WALL MOUNTED TV 3
TV-02 WALL MOUNTED MONITOR 2
TVAR-01 TV ARM, ARTICULATING 12
WHEE-01 WHEELCHAIR 1

430 East 51st Place


Chicago, Illinois 60615

*SEE Q SERIES FOR OWNER


Project Name
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS
100 LEVEL EQUIPMENT PLAN

Sheet Name

Drawing No. FFE2-1


Department of Capital Planning & Policy
Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

1 2 3
DIRECTOR STAFF
JANITOR'S CHANGING
OFFICE OFFICE I.T. TOILET STAFF
WOMENS MENS CLOSET ROOM
107 108 109 110 111 113B 113
75SF 83SF 62SF
112 50SF 113A 210SF
33SF 20SF
LEP3028L LEP3028R T−38 T−38
A

C−11

C−11
X

X
15121−P

15121−P
29M

29M
C−11

C−11
15121−P

15121−P
HCT

HCT
42x24 42x24
FB FB

72x15x15 LD

72x15x15 LD
36x36 36x36

66
72x30

72x30
C−8

72

72
C−1G

66
15121−P 15121−P

C−1G

30/4
8
C−
C−11 C−11

C−8
8
LEP3028R LEP3028L

C−3

C−
B
CONFERENCE

C−2B C−2B
1
2'-10 _ "
SOILED

30/4

HIGS6
4 2−HIGH

C−3
C−2B
102 LOCKERS
STORAGE

HIGS6
HIGS6
2'-11"
207SF
118

C−3

C−3
B
100SF

P 96

B
HT LH
CORRIDOR

C−3
PAT. TOILET CORRIDOR

42x 96
B

C−3
114 100C 100D CLEAN WATER

B
SUPPLY TREATMENT

C−3
CORRIDOR 40SF

B
C−3
B
3'-5" 100B 119 125
100SF 329SF

U4
C−14A
C−14A
C−14EC−14A C−14B
MED. PREP. B
base
1392−C
add base
1392−M 1392−C
add
1392−OBA 115
12

U4
88SF

628S−28M
WHEELCHAIR 80SF
EXAM

628S−28M
106 1 EQUIP.

U4
76SF BBF
REPAIR
108SF
1392−C 1392−M 1392−C
base add add base
C−14EC−14A C−14A
C−14A
120
C−14A

SINGLE
C−9 C−8 C−1G C−1G 11

C−1G
C−1G
C−14A
C−14A
C−14EC−14A 80SF 147SF
WAITING C−14A

628S−28M
base add base add
1392−C 1392−M 1392−C
NURSE
ROOM

628S−28M
2 STATION
101 76SF
C−1G C−1G
1392−
OB
LAB
121
ba
1392−E C−14seB C add
−14A BBF
10
C−14G

U5
80SF 63SF

628S−28M
30/2 30/2
628S−09M−750

628S−28M
3

U5
C−1G
76SF
STORAGE
RECEPTION

U5
105 122 Holabird & Root, LLC expressly disclaims any
9 114SF

628S−28M
71SF responsibility arising from any unauthorized use of these

628S−28M
82SF

U4
4
76SF plans, drawings and notes. Any authorization must be in
C−2 C−2 writing.
VESTIBULE 1G 6 7 8
FF

C− HIGS6 HIGS6

100A
F

3S
xB2B4

HF2
80SF 80SF 130SF This drawing copy may have been reproduced at a size
54
8
542

MP6628
MP

42x15x15 LL

EP2428R
EP2428L
EP
24 2

628S−28M
60 x 628S−28M 628S−28M

different than originally drawn. The Owner and Architect


8L

42

5
0
8
112

66x30
EP

628S−28M
FB

2'-10"
8R

assume no responsibility for use of incorrect scale.


MP
242

602
8
76SF
EP

HIG
S6
54x2442

42x15x15 LL

C−
Drawings are not to be scaled.
HIG
S6 2B
30/4

C−

D
BBF

2B

DIETITIAN Not published - All rights reserved.


SOCIAL TREATMENT PRIVATE W.C. ELECTRICAL MECHANICAL
103 WORKER 117A 123 124
89SF AREA PAT./ISOLATION
104 116 117
47SF 118SF 102SF
101SF

1 100 LEVEL FURNITURE PLAN - FOR REFERENCE ONLY


FFE2-2 1/8" = 1'-0"

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn Author

Checked Checker
Proj. Arch./Eng. Approver

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

100 LEVEL FURNISHINGS PLAN -

FOR REFERENCE ONLY FOR REFERENCE ONLY


Sheet Name

Drawing No. FFE2-2


PROVIDENT HOSPITAL - RENAL
DIALYSIS CENTER
430 EAST 51ST PLACE CHICAGO, IL 60615

FOR THE:
COOK COUNTY HEALTH & HOSPITALS SYSTEM
DEPARTMENT OF FACILITIES

UNDER:
BOARD OF DIRECTORS
OF THE COOK COUNTY HEALTH & HOSPITALS SYSTEM
ARCHITECT / STRUCTURAL ENGINEER
HOLABIRD & ROOT LLC ISSUED BY:
140 SOUTH DEARBORN STREET
SUITE 500
CHICAGO, IL 60603
OFFICE OF THE CHIEF PROCUREMENT OFFICER
312.357.1771 TEL
312.357.1909 FAX
SUPPLY CHAIN MANAGEMENT
www.holabird.com BUILDING CODE CERTIFICATION STATEMENT
ISSUE FOR BID 09/07/2018 "I CERTIFY THAT THESE DRAWINGS WERE PREPARED BY ME
OR UNDER MY DIRECT SUPERVISION AND CONTROL AND TO
MECHANICAL, ELECTRICAL, & THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH THE
PLUMING DESIGN ENGINEERS REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE."
MEPIS INC
36 SOUTH WABASH AVE
SUITE 310
CHICAGO, IL 60603
312.279.1185 TEL
BID DEPOSIT TO BE 1% OF TOTAL BID
https://www.mepisinc.com BIDS SHALL BE EXECUTED IN TRIPLICATE
ALL SIGNATURES SHALL BE SWORN TO BEFORE A NOTARY PUBLIC
ARCHITECT'S SIGNATURE
PROJECT

RENAL DIALYSIS CENTER : ISSUED FOR: ADDENDUM #1 SEPTEMBER 13, 2018


COOK COUNTY/PROVIDENT HOSPITAL
430 E. 50th Pl. CHICAGO, IL 60615 Department of Capital Planning & Policy
DRAWING INDEX * INDICATES SHEET WAS ISSUED WITH THIS REVISION Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
GENERAL INTERIORS for their confidential use only. In consideration of the loan
G0-0 COVER SHEET ID1-1 INTERIOR FINISH SCHEDULE * P0600 DETAILS of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
* G1-1 GENERAL INFORMATION & DRAWING INDEX ID2-1 100 LEVEL INTERIOR FINISHES PLAN * PD101 LEVEL 01 - PLUMBING - DEMOLITION PLAN reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.
LIFE SAFETY FFE FIRE PROTECTION
LS1-1 CODE INFORMATION & LIFE SAFETY PLAN FFE2-1 100 LEVEL EQUIPMENT PLAN * F0001 SYMBOLS, ABBREVIATIONS, NOTES & DETAILS
FFE2-2 100 LEVEL FURNISHINGS PLAN - FOR REFERENCE ONLY
DEMOLITION * F0100 LEVEL 01 - FIRE PROTECTION PLAN
DA2-1 100 LEVEL DEMOLITION PLAN AND REFLECTED CEILING OWNER EQUIPMENT (FOR REFERENCE ONLY)
DEMOLITION PLAN Q1-1 OWNER EQUIPMENT SCHEDULE FD101 LEVEL 01 FIRE PROTECTION DEMOLITION
DA2-2 100 LEVEL TRENCHING PLAN
MECHANICAL ELECTRICAL
ARCHITECTURAL M0001 SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES E0001 NOTES, LEGENDS, SYMBOLS AND ABBREVIATIONS
A1-1 ARCHITECTURAL SYMBOLS & ABBREVIATIONS
M0101 LEVEL 01 - HVAC DUCTWORK PLAN * E0101 LEVEL 01 LIGHTING PLAN
A2-1 100 LEVEL FLOOR PLAN & DIMENSION PLAN M0102 ROOF - HVAC DUCTWORK PLAN
A2-3 ROOF PLAN * E0201 LEVEL 01 POWER PLAN
M0501 SCHEDULES
A3-1 100 LEVEL REFLECTED CEILING PLAN * E0301 LEVEL 01 SYSTEMS PLAN
M0601 CONTROL DIAGRAMS E0302 ROOF LEVEL
A4-1 BUILDING ELEVATIONS
A4-2 BUILDING SECTIONS M0701 DETAILS * E0401 ELECTRICAL ENLARGED PLANS

A6-1 TYPICAL PLANS, ELEVATIONS, & DETAILS MD101 LEVEL 01 - HVAC DEMOLITION PLAN * E0521 POWER RISER DIAGRAMS
A6-2 TOILET ROOMS MD102 ROOF - HVAC DEMO PLAN
* E0601 LIGHTING SCHEDULES
A7-1 PARTITION TYPES & DETAILS PLUMBING * E0621 POWER SCHEDULES
A7-2 DOOR SCHEDULE, BORROWED LIGHT SCHEDULE, * P0001 SYMBOLS, ABBREVIATIONS & GENERAL NOTES
ELEVATIONS, & DETAILS E0701 ELECTRICAL DETAILS
* P0100 LEVEL 01 - PLUMBING - STORM, SANITARY & VENT PLAN E0702 ELECTRICAL DETAILS
A8-1 INTERIOR ENLARGED PLANS * P0100U UNDERGROUND PLUMBING PLAN
A8-2 INTERIOR ELEVATIONS ED101 LEVEL 01 DEMOLITION PLAN
A8-3 INTERIOR ELEVATIONS * P0200 LEVEL 01 - PLUMBING - DOMESTIC WATER PLAN
A8-4 TYPICAL CASEWORK DETAILS
A8-5 TYPICAL CASEWORK DETAILS * P0400 SANITARY WASTE AND VENT RISER DIAGRAM
A8-6 CASEWORK DETAILS * P0401 DOMESTIC WATER AND TEMPERED WATER RISER
A8-7 BUILDING SIGNAGE DIAGRAM

A9-1 INTERIOR DETAILS * P0500 SCHEDULES


PROJECT LOCATION
AREA OF WORK
N
Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
ADD LANDSCAPING AT
REMOVED WALK TO Not published - All rights reserved.
MATCH EXISTING

RENAL DIALYSIS CENTER


430 E. 50TH PL.
W. 50th Place CHICAGO, IL 60615

2 09/13/2018 ADDENDUM #1
1 09/07/2018 ISSUED FOR BID
No. Date Issue
COORD. NEW
GENERATOR
LOCATION W/MEP Project Number 15849
EXISTING LANDSCAPE /
WALKS TO REMAIN - NEW FENCED Drawn S. DENNY
NO NEW WORK ENCLOSURE
Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER
PROJECT TEAM
EXISTING PARKING
LOT TO REMAIN -
NO NEW WORK
ARCHITECTURE & MECHANICAL, PLUMBING, Provident Hospital - Renal
STRUCTURAL ENGINEERING ELECTRICAL, & FIRE PROTECTION Dialysis Center
ENGINEERING

HOLABIRD & ROOT LLC MEPIS INC S. Vince


140 SOUTH DEARBORN 36 SOUTH WABASH AVE
nn es Ave. 430 East 51st Place
Chicago, Illinois 60615
SUITE 500 SUITE 310
CHICAGO, IL 60603 CHICAGO, IL 60603 Project Name

312.357.1771 TEL 312.279.1185 TEL


312.357.1909 FAX 312.279.1186 FAX GENERAL INFORMATION &
DRAWING INDEX
www.holabird.com https://www.mepisinc.com
1 Site Plan
Sheet Name

G1-1 1/16" = 1'-0"


Drawing No. G1-1
SYMBOLS: FINISHES INTERIOR FINISH SCHEDULE
THE NOTES BELOW APPLY TO ID SERIES SHEETS ACT - ACOUSTICAL CEILING TILE PFT - PORCELAIN FLOOR TILE RS - RESILIENT SHEET WS - WINDOW SHADES
ONLY. CODE: ACT1 CODE: PFT1 CODE: RS1 CODE: WS1
SPEC#: 09 51 23 SPEC#: SPEC#: 09 65 16 SPEC#: 12 24 13
1. INDICATES ROOM FINISH. REFER TO FINISH MFR: ARMSTRONG MFR: MIRAGE MFR: TBD MFR: SEE SPEC
SCHEDULE ON SHEET ID1-1 FOR FINISH PRODUCT: HEALTH ZONE ULTIMA 1902 PRODUCT: TRANSITION STYLE: TBD COLOR: TBD
INFORMATION. SIZE: 24"x24"x1" COLOR: MILANO TR05 COLOR: TBD NOTES: ALL ROOMS WHERE NOTED
GRID: SILHOUETTE 1/8" REVEAL, 24x24, WHITE SIZE: 12x24 NOTES: TBD
WALL P1 AC1
CEILING NOTES: GENERAL, TYP. NOTES: TOILET ROOMS & JANITOR CLOSETS
C1 WB1 CODE: RS2 WT - WALK-OFF MAT
FLOOR BASE SPEC#: 09 65 16 CODE: WT1
CG - CORNER GUARDS PL - PLASTIC LAMINATE MFR: TBD SPEC#: 12 48 13
2. INDICATES TRANSITION DETAIL OR FINISH
CODE: CG1 CODE: PL1 STYLE: TBD MFR: MILLIKEN Department of Capital Planning & Policy
SPEC#. 10 26 00 SPEC#: 06 41 16 COLOR: TBD PRODUCT: TERGO 11C
CHANGE. REFER TO SHEET ID1-1 FOR MFR: TBD MFR: ARPA NOTES: TBD SIZE: MODULAR GRID Bureau of Asset Management
FINISH DETAIL. COLOR: TBD COLOR: LARIX 4367 COLOR: GRAPHITE Notice: This drawing has not been published and is the
T1.1 FINISH: TBD FINISH: STANDARD NOTES: TBD sole property of Cook County. It is loaned to the borrower
NOTES: TBD NOTES: ALL VERTICAL CASEWORK & LOCKERS SS - SOLID SURFACE for their confidential use only. In consideration of the loan
CODE: SS1 of this drawing, the borrower promises and agrees to
3. INDICATES LOCATION OF ACCENT CODE: PL2 SPEC#: 12 36 61.16 return it upon request and agrees that it shall not be
MATERIAL. REFER TO SHEET ID1-1 FOR P - PAINT SPEC#: 06 41 16 MFR: CORIAN reproduced, copied, loaned, or otherwise disposed of
FINISH INFORMATION. FLOOR TO CEILING CODE: P1 MFR: WILSONART COLOR: GLACIER WHITE directly or indirectly, nor used for any purpose other than
U.N.O. SPEC#: 09 91 23 COLOR: LINEN MATTE D427-60 NOTES: ALL COUNTERTOPS for which it is furnished, in whole or part.
P5 MFR: BENJAMIN MOORE FINISH: MATTE
COLOR: OC-65 CHANTILLY LACE NOTES: TBD
FINISH: SATIN SV- SOLID VINYL
NOTES: GENERAL, TYP. CODE: SV1
GENERAL NOTES: FINISHES PWT - PORCELAIN WALL TILE SPEC#: 09 65 19
THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY. CODE: P2 CODE: PWT1 MFR: ARMSTRONG FLOORING
SPEC#: 09 91 23 SPEC#: 09 30 13 STYLE: STRIATIONS BBT
MFR: BENJAMIN MOORE MFR: MIRAGE COLOR: TWILIGHT
1. FINISHES INDICATED IN FINISH SCHEDULE ARE BASIS OF DESIGN. SEE COLOR: 2065-10 ADMIRAL BLUE PRODUCT: TRANSITION SIZE: 12x24
SPECIFICATIONS FOR PROJECT REQUIREMENTS. FINISH: SATIN COLOR: MILANO TR05 NOTES: TBD
NOTES: ACCENT COLOR SIZE: 12x24
2. ALL WALL FINISHES TO COMPLY OR SUPERCEDE CLASS I FIRE RATING. NOTES: TOILET ROOMS CODE: SV2
CODE: P4 SPEC#: 09 65 19
3. REFER TO A3 SERIES FOR CEILING PATTERNS. SPEC#: 09 91 23 CODE: PWT2 MFR: ARMSTRONG FLOORING
MFR: BENJAMIN MOORE SPEC#: 09 30 13 STYLE: STRIATIONS BBT
4. REFER TO A6 SERIES FOR RESTROOM ENLARGED PLANS AND COLOR: 2064-20 PATRIOT BLUE MFR: MIRAGE COLOR: ATMOSPHERE
ELEVATIONS. FINISH: SATIN PRODUCT: TRANSITION SIZE: 12X24
NOTES: ACCENT COLOR COLOR: FADE TR 04-05 NOTES: TBD
5. REFER TO A7 SERIES FOR ALL DOOR TYPES AND FINISHES. ALL PAINTED SIZE: 12x24
DOORS AND FRAMES TO HAVE SEMI-GLOSS FINISH. CODE: P5 NOTES: TBD
SPEC#: 09 91 23 WP-VINYL WALLCOVERING
6. REFER TO A8 SERIES FOR ALL ELEVATIONS AND INTERIOR DETAILS. MFR: BENJAMIN MOORE CODE: PWT3 CODE: WP1
COLOR: WHITE SPEC#: 09 30 13 SPEC#: 09 72 10
7. ALL UNFINISHED GPDW (NOT PTD. OR WITH WALLCOVERING) TO BE TAPED FINISH: FLAT MFR: MIRAGE MFR: INPRO
AND SANDED. NOTES: ALL CEILINGS PRODUCT: TRANSITION PRODUCT: RICCOCHET, PASSAGE
COLOR: TORINO TR04 COLOR: TBD
8. ALL PAINTED WALL TO HAVE SATIN PAINT FINISH. CODE: P6 SIZE: 12x24 NOTES: TREATMENT AREA
SPEC#: 09 91 23 NOTES: TBD
9. ALL PAINTED CEILINGS TO BE FLAT PAINT FINISH. MFR: BENJAMIN MOORE CODE: WP2
COLOR: TO MATCH ADJACENT WALL SPEC#: 09 72 10
10. ALL DOORS TO BE BIRCH RIFT CUT, UNO. FINISH: SEMI-GLOSS RB - RUBBER WALL BASE MFR: INPRO
NOTES: ALL DOORS & FRAMES CODE: RB1 PRODUCT: RICCOCHET, PASSAGE
SPEC#: 09 65 13 COLOR: TBD
MFR: ROOPE NOTES: TREATMENT AREA
PBT - PORCELAIN BASE TILE COLOR: 123 CHARCOAL
CODE: PBT1 STYLE: 4" COVE VINYL WALL BASE
SPEC#: NOTES: GENERAL, TYP.
KEYNOTES: FINISHES MFR: MIRAGE
THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY. PRODUCT: TRANSITION
COLOR: MILANO TR05
SIZE: 6x24
1 KEYNOTE #1 NOTES: TOILET ROOMS & JANITOR CLOSETS

2 KEYNOTE #2

GENERAL NOTES: THRESHOLDS Holabird & Root, LLC expressly disclaims any
1. ALL ALUMINUM THRESHOLDS TO BE FIRE RATED( FR ) & CONFORM TO RESILIENT FLOORING 2 responsibility arising from any unauthorized use of these
LOCAL BUILDING CODES. plans, drawings and notes. Any authorization must be in
THRESHOLD AT CENTER OF writing.
2. USE ALUMINUM THRESHOLD UNDER ALL RATED DOORS (UNLESS FLOOR IS TRANSITION AT CENTER
DOOR
EXPOSED CONCRETE.) OF DOOR
This drawing copy may have been reproduced at a size
ALUMINUM SADDLE VINYL TRANSITION different than originally drawn. The Owner and Architect
DOOR
5/8" UNDERCUT @ DOOR U.N.O.

5/8" UNDERCUT @ DOOR U.N.O.


3. ALL ALUMINUM THRESHOLDS TO BE ANCHORED TO CONCRETE WITH FLAT THRESHOLD (NGP #410) WITH (JOHNSONITE assume no responsibility for use of incorrect scale.
HEAD METAL (FINISH TO MATCH ALUMINUM) EXPANSION ANCHORS. EXPANSION ANCHOR, SHIM AS #CTA-XX-N) ADHERED TO Drawings are not to be scaled.
5/8" UNDERCUT @ DOOR U.N.O.

REQUIRED. CONCRETE
4. RESILIENT = LVT OR SHEET VINYL FLOORING RESILIENT FLOORING 1 Not published - All rights reserved.
RESILIENT FLOORING 1

1/8"
1/8"
1/8"

1/8"
5. CARPET = CARPET OR CARPET TILE

1/8"
6. TILE = PORCELAIN OR CERAMIC TILE
CONCRETE
7. EPOXY = POURED EPOXY OR URETHANE FLOORING CONCRETE CONCRETE

8. DOOR TYPE AND THRESHOLD DIMENSIONS WILL VARY. SEE DOOR RESILIENT FLOOR RESILIENT FLOORING 2
SCHEDULE.

9. PROVIDE LATEX UNDER CARPET TO MAKE CARPET FIT TIGHTLY UNDER


DIVIDER STRIP AS NECESSARY.

T1.0 NO THRESHOLD T1.1 SILL W/ METAL THRESHOLD T1.2 SILL W/ VINYL THRESHOLD
RESILIENT RESILIENT RESILIENT RESILIENT RESILIENT RESILIENT

1 09/07/2018 ISSUED FOR BID


TRANSITION COLORS No. Date Issue
TX.0 - NO THRESHOLD
TX.1 - ALUMINUM WITH CLEAR COAT
TX.2 - VINYL - JOHNSONITE, COLOR TBD RESILIENT FLOORING
Project Number 15849
TRANSITION AT CENTER RESILIENT FLOORING Drawn S. DENNY
OF DOOR
VINYL WHEELED TRAFFIC DOOR Checked K. BOYER
1" UNDERCUT @ DOOR U.N.O.

TRANSITION
5/8" UNDERCUT @ DOOR U.N.O.

Proj. Arch./Eng. K. SCHUSTER


(JOHNSONITE VINYL TRANSITION
#CTA-XX-K)
TILE
1/8"
1/8"

Provident Hospital - Renal


3/8"
3/8"

WALK-OFF MAT Dialysis Center


SEALANT TO MATCH ALUMINUM TRACK BASE
TILE GROUT COLOR (JOHNSONITE #MT-00-A)
CONCRETE

T2.2 SILL W/ VINYL THRESHOLD T3.2 SILL W/ VINYL THRESHOLD


RESILIENT TILE RESILIENT WALK-OFF MAT

430 East 51st Place


Chicago, Illinois 60615

Project Name

INTERIOR FINISH SCHEDULE

Sheet Name

Drawing No. ID1-1


SYMBOLS: FINISHES
THE NOTES BELOW APPLY TO ID SERIES SHEETS
ONLY.

1. INDICATES ROOM FINISH. REFER TO FINISH


SCHEDULE ON SHEET ID1-1 FOR FINISH
INFORMATION.
WALL P1 AC1
CEILING
C1 WB1
FLOOR BASE

2. INDICATES TRANSITION DETAIL OR FINISH


CHANGE. REFER TO SHEET ID1-1 FOR
FINISH DETAIL.
Department of Capital Planning & Policy
T1.1
Bureau of Asset Management
3. INDICATES LOCATION OF ACCENT Notice: This drawing has not been published and is the
MATERIAL. REFER TO SHEET ID1-1 FOR sole property of Cook County. It is loaned to the borrower
FINISH INFORMATION. FLOOR TO CEILING for their confidential use only. In consideration of the loan
U.N.O. of this drawing, the borrower promises and agrees to
P5 return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.
GENERAL NOTES: FINISHES
THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY.

1. FINISHES INDICATED IN FINISH SCHEDULE ARE BASIS OF DESIGN. SEE


SPECIFICATIONS FOR PROJECT REQUIREMENTS.

2. ALL WALL FINISHES TO COMPLY OR SUPERCEDE CLASS I FIRE RATING.

3. REFER TO A3 SERIES FOR CEILING PATTERNS.

4. REFER TO A6 SERIES FOR RESTROOM ENLARGED PLANS AND


ELEVATIONS.

5. REFER TO A7 SERIES FOR ALL DOOR TYPES AND FINISHES. ALL PAINTED
DOORS AND FRAMES TO HAVE SEMI-GLOSS FINISH.
EXIST ACT1 EXIST ACT1 P1 ACT1 P1 ACT1 P1 N.G. P1 ACT1 P1 ACT1
EXIST EXIST EXIST EXIST SV2 RB2 SV2 RB2 SV2 RB1 PFT1 PBT1 PFT1 PBT1 6. REFER TO A8 SERIES FOR ALL ELEVATIONS AND INTERIOR DETAILS.

7. ALL UNFINISHED GPDW (NOT PTD. OR WITH WALLCOVERING) TO BE TAPED


A AND SANDED.

T2.2
P1 ACT1 8. ALL PAINTED WALL TO HAVE SATIN PAINT FINISH.
SV1 RB2
9. ALL PAINTED CEILINGS TO BE FLAT PAINT FINISH.
T1.0
10. ALL DOORS TO BE BIRCH RIFT CUT, UNO.
T1.0 P1 ACT 1 T1.0 T1.2 P1 ACT1 T1.2 T1.2 T2.2 T1.2
T1.0 P1 ACT1 11. EXIST ROOM FINISH IS EXISTING TO REMAIN, CLEAN.
SV1 RB2 CG1
RS1 RB2 CG1 CG1 RS1 RB2
P1 ACT1 CG1 P1 ACT1
CG1
SV1 RB1 SV1 RB2
T1.2 T1.2
P1 ACT1
T2.2
B KEYNOTES: FINISHES
CG1 P1 ACT1 P1 ACT1 P1 ACT1
P2 PFT1 PBT1 THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY.
RS1 RB2 RS2 RB1 RS2 RB1
CG1 T1.2
P1 ACT1 1 KEYNOTE #1
P1 ACT1
RS2 RB1
P1 ACT1 SV2 RB2 T1.2 P1 - 2 KEYNOTE #2
SV1 RB2 SC RB2
P1 ACT1
P1 ACT1 RS2 RB2
P3 T1.2
RS2 RB1

C Holabird & Root, LLC expressly disclaims any


P1 ACT1 responsibility arising from any unauthorized use of these
P3 P1 ACT1 T1.2
SV1 RB2 plans, drawings and notes. Any authorization must be in
P1 P5 SV2 RB2 CG1 writing.
CG1 CG1
WT1 RB2 T1.2 T1.2 P1 ACT1 P1 ACT1
T1.0 T1.2 This drawing copy may have been reproduced at a size
RS1 RB1 RS2 RB2
different than originally drawn. The Owner and Architect
T1.2 assume no responsibility for use of incorrect scale.
P1 ACT1 Drawings are not to be scaled.
P1 ACT1 T2.2
RS2 RB1
RS2 RB1
Not published - All rights reserved.

D
P1 ACT1
SV2 RB2 P1 ACT1 P1 ACT1
SV2 RB2 PFT1 PBT1

1 2 3

1 09/07/2018 ISSUED FOR BID


1
ID2-1
100 LEVEL FINISH PLAN
1/8" = 1'-0"
No. Date Issue

Project Number 15849


Drawn A. BAHENA

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

100 LEVEL INTERIOR FINISHES


PLAN
Sheet Name

Drawing No. ID2-1


SYMBOLS: LIFE SAFETY PLUMBING FIXTURES - TABULATION PER IPC 2004 SECTION 890.810 & APPENDIX A.TABLE B
CODE INFORMATION SF PER PERSON OCCUPANT LOAD OCCUPANT LOAD OCCUPANT LOAD
OCCUPANCY TYPE (IPC) (IPC) BUILDING TYPE (IPC) AREA (TOTAL) (MALE) (FEMALE)
PROJECT- RENOVATED INTERIOR SPACE IN AN EXISTING BUILDING
XX SPACE OCCUPANCY COUNT
Storage/Shipping Area 400 SF Office Buildings / Public 548 SF 1.369428 0.684714 0.684714
XXXXXXX SPACE FUNCTION
APPLICABLE CODES Buildings
Office Buildings 200 SF Office Buildings / Public 3423 SF 17.114801 8.557401 8.557401
THESE PLANS & SPECIFICATIONS HAVE BEEN PREPARED IN ACCORDANCE WITH THE Buildings
### OCCUPANT LOAD AT
Assembly Places - Facilities for 50 SF Office Buildings / Public 395 SF 7.898762 3.949381 3.949381
FOLLOWING BUILDING CODES & REGULATIONS. EGRESS DOOR Spectator Events; Worship Places and Buildings
2017 THE CITY OF CHICAGO BUILDING CODE Funeral Homes
4366 SF 26.382992 13.191496 13.191496
2012 NFPA101 EGRESS PATH
MINIMUM PLUMBING FIXTURES (IPC SECTION 890.APPENDIX A.TABLE B)
2015 INTERNATIONAL ENERGY CONSERVATION CODE
OFFICE (18 P) ASSEMBLY (8 P)
DEAD END CORRIDOR
REFERENCE BASIC BUILDING INFORMATION REMARKS MALE FEMALE MALE FEMALE
OCCUPANT LOAD 9 9 4 4
DIVISION 3 USE & OCCUPANCY CLASSIFICATION
1 HR RATED WALL
OFFICE - REQUIRED ASSEMBLY - REQUIRED TOTAL - REQUIRED ACTUAL
Department of Capital Planning & Policy
PLUMBING FIXTURE MALE FEMALE MALE FEMALE MALE FEMALE MALE FEMALE UNISEX Bureau of Asset Management
2 HR RATED WALL
13-56-120 CLASS F - BUSINESS WATER CLOSET 1 1 1 1 2 2 2 3 3 Notice: This drawing has not been published and is the
13-56-300 TRANSACTION OF BUSINESS FOR THE RENDERING OF PROFESSIONAL SERVICES - RENAL DIALYSIS AND WAITING AREA sole property of Cook County. It is loaned to the borrower
URINAL 50% - 50% - 50% - 1 - -
RENAL DIALYSIS EXISTING 2 HR RATED WALL for their confidential use only. In consideration of the loan
13-56-320 OCCUPANCY CONTENT : 100 SF PER PERSON - DIALYSIS CENTER LAVATORIES 1 1 1 1 2 2 2 2 3
300 SF PER PERSON - STORAGE ROOMS of this drawing, the borrower promises and agrees to
DRINKING FOUNTAINS 1 1 1 2
return it upon request and agrees that it shall not be
SERVICE SINK 1 PER FLOOR 1 PER FLOOR 1 PER FLOOR 1 PER FLOOR reproduced, copied, loaned, or otherwise disposed of
13-56-250 AUXILIARY USE: SPACES INCIDENTAL TO PRINCIPAL USE - ASSEMBLY & STORAGE WAITING AREA ASSEMBLY <100 directly or indirectly, nor used for any purpose other than
EGRESS - OCCUPANCY - TABULATION PER CBC, 2017
- SHALL COMPLY WITH SPECIFIC REQUIREMENTS OF THE USE PEOPLE IS CLASSIFIED AS THE SAME for which it is furnished, in whole or part.
- LIMITED TO 5% OF BUILDING AREA BUILDING OCCUPANCY OCCUPANCY (CBC 2017) AREA SF / OCCUPANT OCCUPANCY
- SPECIAL SEPARATION UNDER 13-56-280 NOT REQUIRED
Accessory storage areas, mechanical equipment 987 SF 300 9
room
DIVISION 4 SPECIAL REQUIREMENTS ON USE & OCCUPANCY Assembly - Without fixed seating - Concentrated 395 SF
(chairs only)
7 57

CHAPTER NOT APPLICABLE TO BUILDING SINCE NOT A HIGH RISE OR ATRIUM. Business areas 3009 SF 100 38
4391 SF 104

DIVISION 5 GENERAL BUILDING HEIGHT & AREA LIMITATIONS OCCUPANCY COUNT (EGRESS)

PROVIDENT RENAL DIALYSIS - EXISTING TYPE II NON-COMBUSTIBLE CONSTRUCTION NO CHANGE TO EXISTING BUILDING LEVEL 100 ANCILLARY: 9P
HEIGHT OR AREA ASSEMBLY: 57 P
TABLE 13-48 BLDG FLOOR TO # OF BUILDING BUSINESS: 38 P
104 P
FLOOR PROJECT AREA AREA FLOOR HEIGHT STORIES HEIGHT
100 LEVEL 6600 SF 6600 SF - 1 STORY 20'

HEIGHT:
BUILDING = SEE TABLE ABOVE (HEIGHT COMPLIES -
EXISTING (NO CHANGE)
AREA:
BUILDING = SEE TABLE ABOVE (AREA NOT LIMITED - AREA COMPLIES -
EXISTING (NO CHANGE)

DIVISION 6 TYPES OF CONSTRUCTION: TYPE II NON-COMBUSTIBLE CONSTRUCTION 2


A4-2
MAX. CAPACITY @ MAX. CAPACITY @
TYPE II NON-COMBUSTIBLE CONSTRUCTION (EXISTING BUILDING) EXIT DOOR
EXIT DOOR
135P @ 40" DOOR 135P @ 40" DOOR
TYPE II, NON-COMBUSTIBLE CONSTRUCTION, SHALL BE THAT CONSTRUCTION
IN WHICH ALL STRUCTURAL ELEMENTS, INCLUDING WALLS, BEARING
PARTITIONS, FLOORS, CEILINGS, ROOFS AND THEIR SUPPORTS, ARE OF NON-
COMBUSTIBLE MATERIALS BUT WHICH ARE GENERALLY NOT FIRE PROTECTED 1 STAFF
WOMENS MENS TOILET 3
EXCEPT AS REQUIRED IN SECTION 13-60-100. FIRE RETARDENT TREATED WOOD 1 1 I.T.
MA BE USED IN ROOF FRAMING AND ROOF SHEATHING OF ONE STORY BUS.
BUS. BUS.
BUILDINGS ONLY. 1 1 52
J.C. BUS.

DIVISION 7 FIRE-RESISTANCE-RATED CONSTRUCTION 3


BUS.
52 WATER
SUPPORTING MEMBERS - FIRE RESISTANT VALUES TREATMENT
RATING OF ANY STRUCTURAL MEMBER SHALL NOT BE LESS THAN THE REQUIRED 125
RATING OF CONSTRUCTION SUPPORTED BY SUCH MEMBER. PAT. TOILET 44" REQ.
1 1 1 58" PROV.
FIRE WALLS BUS. Holabird & Root, LLC expressly disclaims any
STORAGE STORAGE
RATING U.L. ASSEMBLY NUMBER responsibility arising from any unauthorized use of these
1- HOUR U465 plans, drawings and notes. Any authorization must be in
1 - HOUR/SMOKE U465 57 2 writing.
2 - HOUR U411 ASSEMBLY 2 WATER
1 TREATMENT This drawing copy may have been reproduced at a size
BUS.
A4-2 2 2 different than originally drawn. The Owner and Architect
THROUGH PENETRATION AND FIRE STOP SYSTEM BUS. assume no responsibility for use of incorrect scale.
BUS.
TYPE RATING U.L. ASSEMBLY NUMBER Drawings are not to be scaled.
WALL PENETRATION 1,2 &4 HR SYSTEM 550, 282, 284 Not published - All rights reserved.
CURTAIN WALL/SLAB 2 HR J900 SERIES 1
52 1
FLOOR PENETRATION 1,2 & 4 HR SYSTEM 429, 284
MAX. CAPACITY @ BUS. BUS.
1
EXIT DOOR MAX. CAPACITY @
FIRE ALARM SYSTEM 135P @ 40" DOOR STORAGE EXIT DOOR
DIRECT FIRE DEPARTMENT CONNECTION 135P @ 40" DOOR
52
CODED 15
52
BUS. W.C.
EMERGENCY POWER 1 2 1 1
BUS. 2
GENERATING SET BUS. ELEC. MECH.
BUS.
FOUR SOURCE COMED FEED

CHAPTER 8 INTERIOR FINISHES


CLASS FRAME SPREAD INDEX SMOKE DEVELOPED INDEX SEE TABLE 1018.1 FOR CORRIDOR DEAD END CORRIDOR TD=127' TD=135' DEAD END CORRIDOR 1 09/07/2018 ISSUED FOR BID
CLASS A 0- 25 0 - 400 WALLS DISTANCE = 9' - 9" DISTANCE = 9' - 6"
No. Date Issue
CLASS B 26-75 0 - 450
CLASS C 76-200 0 - 450

INTERIOR FINISH REQUIREMENTS BASED ON GROUP GROUP B ASSEMBLY: A3 REQUIREMENTS FOR BUILDING Project Number 15849
VERTICAL EXITS & EXIT PASSAGEWAYS
EXIT SCCESS CORRIDORS & OTHER TAXIWAYS
ROOMS & ENCLOSED SPACES
B
B
C
B
THAT IS FULLY SPRINKLER
1 100 LEVEL LIFE SAFETY PLAN
LS1-1 1/8" = 1'-0"
Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER
CHAPTER 9 FIRE PROTECTION SYSTEMS
AUTOMATIC SPRINKLER SYSTEMS: TO COMPLY W/THIS SECTION BUILDING HAS AN AUTOMATIC
SPRINKLER SYSTEM - FULL
Provident Hospital - Renal
CHAPTER 10 MEANS OF EGRESS
Dialysis Center
TRAVEL DISTANCES: 127' DIALYSIS STATION 7 TO EXIT SEE 1/LS1-1
135' PRIVATE PATIENT TOILET TO EXIT

CODE ALLOWABLE TRAVEL DISTANCE: 225'


150' FOR BUSINESS USE PER 13-160-140,
PLUS 50%*150'=75' FOR AUTOMATIC SPRINKLER SYSTEM PER 13-160-150(a)

CHAPTER 13 EXIT REQUIREMENTS


430 East 51st Place
ACTUAL CAPACITY OF 40" DOOR = 1.5 UNITS SEE 1/LS1-1 Chicago, Illinois 60615
EXITS: 1.5 UNITS = 90 P/UW AT DOOR
PLUS 50%*90=135 FOR AUTOMATIC SPRINKLER SYSTEM
PER 13-160-150(a) Project Name

REQUIRED CAPACITY OCCUPANCY COUNT = 104 P / 2


OF EXITS: 52 P PER EACH EXIT PATH
CODE INFORMATION & LIFE
SAFETY PLAN
MINIMUM WIDTH OF 36" DOOR = 1.5 UNITS
EXITS: 1 UNIT = 60 P/UW AT DOORS Sheet Name

SWING OF EXIT DOORS: DIRECTION OF TRAVEL


Drawing No. LS1-1
Plan Room Name Room WHO WHO INSTALLS TYPE OF WHO INSTALLS
Item Manufacturer Model Catalog # Qty Ext Qty Accessories Per Each Location Arch Eq # Width (in.) Depth (in.) Height (in.) Weight (lb.) Volts Hertz Amps Description
Count PURCHASES INFRASTRUCTURE INFRASTRUCTURE EQUIPMENT

TREATMENT DIALYSIS MACHINES Fresnius Medical Care North America 2008T 12.0000 1.0000 12.0000 FLOOR DI-01 21.2500 24.8000 58.7000 198.4000 115.00 60.00 12.50 OWNER CONTRACTOR CONDUIT, CABLES, OWNER
DIALYSIS BOX, RO
WATER PIPNG
TREATMENT DIALYSIS RECLINER IOA SUSPEND 12.0000 1.0000 12.0000 FOLD DOWN ARM PANEL, FLOOR DRCL-01 OWNER HENRIKSEN
SOFT GRIP PUSH BAR
TREATMENT DIALYSIS BARIATRIC IOA SUSPEND 1.0000 1.0000 1.0000 FOLD DOWN ARM PANEL, FLOOR DRCL-02 OWNER HENRIKSEN
RECLINER SOFT GRIP PUSH BAR
TREATMENT SCALE, INTEGRATED Welch Allyn ScaleTronix 6102 1.0000 1.0000 1.0000 SCI-01 115.00 60.00 4.10 INTEGRATED SCALE RECESSED IN FLOOR, 825 LB CAPACITY, DIGITAL OWNER CONTRACTOR CONDUIT CONTRACTOR
LED DIPLAY
TREATMENT SCALE, HEIGHT SECCA 222.0000 1.0000 1.0000 1.0000 SCHT-01 12.1000 11.3000 91.3000 MEASURING ROD WITH LARGE MEASURING RANGE

TREATMENT WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 12.0000 1.0000 12.0000 FLOOR WACB-01 12.0000 12.0000 17.0000 18.0000 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
TREATMENT GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 4.0000 1.0000 4.0000 WALL GLBH-01 15.9500 3.9500 10.1000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
TREATMENT CONTAINER, SHARPS DANIELS SHARPSMART INC S22 1001207500 4.0000 1.0000 4.0000 1 ea. WALL BRACKET WALL COSH-01 15.5000 8.2500 17.3000 REUSABLE SHARPS CONTAINER WITH 16 QUART CAPACITY FOR USE OWNER CONTRACTOR BLOCKING CONTRACTOR
IN MODERATE VOLUME AREAS
TREATMENT MOBILE TECHNOLOGY TBD TBD 4.0000 1.0000 4.0000 CPTM-01
CART
TREATMENT TABLE, BEDSIDE STRYKER TRU-FIT 4.0000 1.0000 4.0000 FLOOR TBLB-01 17.5000 31.0000 43.0000 OVERBED TABLE, SINGLE TOP WITHOUT VANITY OWNER NA N/A HENRIKSEN
27-43.75
TREATMENT Waste Can, 08-19 Rubbermaid Commercial 2955 Small 12.0000 1.0000 12.0000 FLOOR WARE-02
Gallon Products Deskside (Beige)
TREATMENT

TREATMENT
TV Arm, Articulating

TV, PATIENT
TBD

TBD
TBD

TBD
12.0000

12.0000
1.0000

1.0000
12.0000

12.0000
CTRTOP TVAR-01

TV-03
Deck mounted articulating monitor arm

Patient TV
OWNER

OWNER
CONTRACTOR

CONTRACTOR
BLOCKING

N/A
CONTRACTOR

OWNER
Department of Capital Planning & Policy
NURSE STATION
ENGAGEMENT

Label Printer Brother International Corporation PT90 2.0000 1.0000 2.0000 PLBL-01
Bureau of Asset Management
NURSE STATION PC COMPUTER WITH TBD TBD TBD 4.0000 1.0000 4.0000 CTRTOP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE Notice: This drawing has not been published and is the
AND MOUSE
NURSE STATION WALL MTD MONITOR TBD TBD WALL TV-2 OWNER CONTRACTOR CONDUIT, CABLES, CONTRACTOR sole property of Cook County. It is loaned to the borrower
BRACKET FACE PLATE
for their confidential use only. In consideration of the loan
EXAM ROOM? Sphygmomanometer,
Aneroid, Mobile
Welch Allyn Inc 767 Mobile w/Weighted
Base & Adult cuff
1.0000 1.0000 1.0000
of this drawing, the borrower promises and agrees to
EXAM ROOM CONTAINER, SHARPS DANIELS SHARPSMART INC S22 1001207500 1.0000 1.0000 1.0000 1 ea. WALL BRACKET WALL COSH-01 15.5000 8.2500 17.3000 REUSABLE SHARPS CONTAINER WITH 16 QUART CAPACITY FOR USE
IN MODERATE VOLUME AREAS
OWNER CONTRACTOR BLOCKING CONTRACTOR
return it upon request and agrees that it shall not be
EXAM ROOM DIAGNOSTIC SET WELCH ALLYN 77791-MX 1.0000 1.0000 1.0000 WALL DISE-01 34.0000 6.0000 12.0000 115.0000 60.0000 1.0000 GREEN SERIES INTEGRATED WALL SYSTEM; INCLUDES WALL
BOARD, G777 WALL TRANSFORMER; 11720 COAXIAL
OWNER CONTRACTOR BLOCKING, CONDUIT CONTRACTOR
reproduced, copied, loaned, or otherwise disposed of
OPHTHALMOSCOPE, 23810 DIAGNOSTIC MACROVIEW OTOSCOPE,
52400-PF SPECULA DISPENSER, 7670-01 WALL ANEROID, 01690-300
SURETEMP PLUS THERMOMETER
directly or indirectly, nor used for any purpose other than
EXAM ROOM GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 1.0000 1.0000 1.0000 WALL GLBH-01 15.9500 3.9500 10.1000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR for which it is furnished, in whole or part.
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
EXAM ROOM STOOL, WITH BACK MIDMARK CORPORATION 277 1.0000 1.0000 1.0000 1 ea. BACKREST (9A366001) FLOOR STWB-01 21.5000 21.5000 35.0000 UPHOLSTERED, PNEUMATIC ADJUSTABLE STOOL WITH BACK; OWNER N/A N/A OWNER
ADJUSTS SEAT HEIGHT OF 18" TO 24.5"; ON 5-STAR CASTER BASE
WITH 3.25" CUSHIONED SEAT; 225 LB. CAPACITY.
EXAM ROOM LIGHT, EXAM/ WELCH ALLYN GS300 44400 1.0000 1.0000 1.0000 FLOOR LIET-01 20.8700 20.8700 58.6600 12.7500 120.0000 60.0000 0.3500 LED EXAM LIGHT ON MOBILE STAND; TOUCHLESS ON/OFF; 20,000 LUX OWNER CONTRACTOR CONDUIT OWNER
TREATMENT
EXAM ROOM TABLE, EXAM, POWER MIDMARK CORPORATION 223 1.0000 1.0000 1.0000 1 ea. LIGHT TABLE MOUNTED FLOOR TAEP-02 29.7000 76.7000 37.0000 325.0000 115.0000 60.0000 12.5000 POWER EXAM TABLE WITH POWER HEIGHT ADJUSTMENT, ADJUSTS OWNER CONTRACTOR CONDUIT, CABLES, CONTRACTOR
(253-002) FROM MINIMUM 18" HEIGHT TO 37" MAXIMUM HEIGHT, POWER FOOT FACE PLATE
CONTROL, 400 LB. PATIENT WEIGHT CAPACITY, POWER BACK,
ADJUSTABLE STIRRUPS WITH FOUR LATERAL POSITIONS, FOOT
EXTENSION SHELF TO EXPAND TABLE LENGTH, HOSPITAL GRADE
ELECTRICAL RECEPTACLE, PAPER ROLL HOLDER HIDDEN UNDER
HEADREST, BUILT-IN PILLOW STORAGE, TREATMENT PAN AND
LEVELING SCREWS; DRAWER SYSTEM; **SPECIFY UPHOLSTERY
COLOR WHEN ORDERING.**
EXAM ROOM WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 1.0000 1.0000 1.0000 FLOOR WACB-01 12.0000 12.0000 17.0000 18.0000 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
EXAM ROOM WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1.0000 1.0000 1.0000 FLOOR WARE-01 19.7000 12.2000 31.6000 14.3000 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
EXAM ROOM WALL MOUNTED TBD TBD 1.0000 1.0000 1.0000 WALL X OWNER CONTRACTOR BLOCKING HENRIKSEN
COMPUTER BRACKET
EXAM ROOM WALL MOUNTED TBD TBD 1.0000 1.0000 1.0000 WALL X OWNER CONTRACTOR CONDUIT, CABLES, OWNER
COMPUTER MOINTOR FACE PLATE
EXAM ROOM MONITOR, PULSE MASIMO CORP RADICAL 7 RDS-3 1 1 1 CTRTOP OWNER CONTRACTOR CONDUIT OWNER
OXIMETER
1.0000 1.0000 1.0000 15.5000 8.2500 17.3000
MEDICINE ROOM CONTAINER, SHARPS DANIELS SHARPSMART INC S22 1001207500 1.0000 1.0000 1.0000 1 ea. WALL BRACKET WALL COSH-01 8.0000 12.0000 15.0000 REUSABLE SHARPS CONTAINER WITH 16 QUART CAPACITY FOR USE OWNER CONTRACTOR BLOCKING CONTRACTOR
IN MODERATE VOLUME AREAS
MEDICINE ROOM CABINET, STORAGE, Lakeside Manufacturing, Inc LNC - 11D 1.0000 1.0000 1.0000 WALL NARC-01 22.8000 27.0000 55.0000 120.0000 60.0000 OWNER CONTRACTOR BLOCKING CONTRACTOR
CLINICAL, NARCOTICS (2-Door/2-Lock)
MEDICINE ROOM DRUG DISPENSING UNIT PYXIS / CAREFUSION PYXIS ES 6-DRAWER 1.0000 1.0000 1.0000 FLOOR DRDU-01 15.9500 3.9500 10.1000 120 60 ES PLATFORM: 6-DRAWER MAIN UNIT OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MAIN FACE PLATE
MEDICINE ROOM GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 1.0000 3.0000 3.0000 WALL GLBH-01 23.7500 27.0000 31.3800 115.0000 60.0000 4.1000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
MEDICINE ROOM REFRIGERATOR, FOLLETT CORPORATION REF4P-KP-00 1.0000 1.0000 1.0000 FLOOR REUN-01 23.75 27 31.38 115 60 4.1 3.9 CU FT CAPACITY; STAINLESS STEEL REFRIGERATOR WITH OWNER CONTRACTOR CONDUIT OWNER
UNDERCOUNTER KEYPAD LOCK; AUTOMATIC DEFROST. FITS BELOW 34" ADA
COUNTERTOPS WITHOUT CASTERS. DEPTH OF CABINET IS 25.6"D.
DEPTH WITH FAÇADE IS 27".
MEDICINE ROOM Monitor, Blood Glucose Johnson & Johnson / Lifescan Division One Touch Surestep 2.0000 1.0000 2.0000
Flexx
MEDICINE ROOM MONITOR, SMART TEMPS SMART LINK 1.0000 1.0000 1.0000 REFRIGERATOR
MOTE-01 2.3000 5.2000 6.9000 3.9000 WIRELESS TEMPERATURE MONITORING FOR OWNER N/A N/A OWNER
TEMPERATURE REFRIGERATORS/FREEZERS. USED ALONG WITH SMART LINK AND
SMART COMMAND CENTER.
MEDICINE ROOM REMOTE MANAGER PYXIS / CAREFUSION SMART REMOTE 1 1 1 REMA-01
REFRIGERATOR 2.3 5.2 6.9 3.9 TEMPERATURE-SENSITIVE MEDICATION DISPENSING AND OWNER N/A N/A OWNER
MANAGER MONITORING SYSTEM SUPPORTS EFFORTS TO MAINTAIN
REGULATORY COMPLIANCE. INTEGRATES W/PYXIS MEDSTATION TO
PROVIDE CONTROLLED POINT-OF-USE ACCESS AND MONITOR
INTERNAL TEMPERATURES OF STORAGE DEVICES.
ELECTRONICALLY ARCHIVES TRANSACTION AND TEMP DATA AND
GENERATES REPORTS NECESSSARY FOR REGULATORY
COMPLIANCE, INVENTORY MANAGEMENT AND BILLING. INCLUDES
SOFTWARE MODULE, ELECTRONIC LOCKING LATCH AND TEMP
SENSOR W/DISPLAY. CAN BE INSTALLED ON MANY, BUT NOT ALL,
COMMERCIALLY AVAILABLE REFRIGERATORS AND WARMERS. TEMP
ACCURACY +/- 1.9 dg FAHRENHEIT PER 1000 HOURS.
1.0000 1.0000 1.0000 120.00 60.00 13.40
EQUIPMENT REPAIR Dialysate Meter DialyGuard pHoenix 2.0000 1.0000 2.0000 MEDI-01 120.00 60.00 13.40
EQUIPMENT REPAIR Dialysis Machines Fresnius Medical Care North America 2008T 1.0000 1.0000 1.0000 FLOOR DI-01 12.0000 12.0000 17.0000 18.0000 OWNER CONTRACTOR CONDUIT, CABLES, OWNER
DIALYSIS BOX, RO
WATER PIPNG
EQUIPMENT REPAIR WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 1.0000 1.0000 1.0000 FLOOR WACB-01 15.9500 3.9500 10.1000 18 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
EQUIPMENT REPAIR GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 1.0000 1.0000 1.0000 WALL GLBH-01 19.7000 12.2000 31.6000 14.3000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
EQUIPMENT REPAIR WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1 1 1 FLOOR WARE-01 19.7 12.2 31.6 14.3 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
2.0000 1.0000 2.0000
CLEAN SUPPLY Pump, Infusion, Single B. Braun Medical Inc. Outlook 300 2.0000 1.0000 2.0000 PINF-01 OWNER OWNER
CLEAN SUPPLY Regulator, Suction, Allied Healthcare Products - Vacutron 22-15-1108 2.0000 1.0000 2.0000 REGI-01 48.0000 24.0000 72.0000 OWNER OWNER

CLEAN SUPPLY
Intermittent/Continous
Flowmeter, Oxygen
Chemetron
Precision Medical Incorporated Chrome (0-15 lpm, 2 1 2 MFLO-01
Holabird & Root, LLC expressly disclaims any
CLEAN SUPPLY CART, SUPPLY INTERMETRO INDUSTRIES CORP. /
DISS Female)
1.0000 1.0000 1.0000 FLOOR CASU-02 23.7500 27.0000 31.3800 115.0000 60.0000 4.1000 WIRE CART WITH (5) SHELVES; BOTTOM SHELF TO BE SOLID; SIDE OWNER N/A N/A OWNER
responsibility arising from any unauthorized use of these
METRO INTERNATIONAL AND BACK ENCLOSURE PANELS; DONUT BUMPERS; WITH TWO
SWIVEL CASTERS AND TWO CASTERS WITH BRAKES.
plans, drawings and notes. Any authorization must be in
1.0000 1.0000 1.0000 12.0000 12.0000 17.0000 18.0000 writing.
LAB REFRIGERATOR, FOLLETT CORPORATION REF4P-KP-00 1.0000 1.0000 1.0000 FLOOR REUN-01 19.7000 12.2000 31.6000 14.3000 115 60 4.1 3.9 CU FT CAPACITY; STAINLESS STEEL REFRIGERATOR WITH OWNER CONTRACTOR CONDUIT OWNER
UNDERCOUNTER KEYPAD LOCK; AUTOMATIC DEFROST. FITS BELOW 34" ADA
COUNTERTOPS WITHOUT CASTERS. DEPTH OF CABINET IS 25.6"D.
DEPTH WITH FAÇADE IS 27". This drawing copy may have been reproduced at a size
LAB WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 1.0000 1.0000 1.0000 FLOOR WACB-01 15.9500 3.9500 10.1000 18 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
different than originally drawn. The Owner and Architect
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
assume no responsibility for use of incorrect scale.
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO Drawings are not to be scaled.
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
LAB WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1.0000 1.0000 1.0000 FLOOR WARE-01 19.7 12.2 31.6 14.3 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL Not published - All rights reserved.
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
LAB GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 2.0000 1.0000 2.0000 WALL GLBH-01 15.95 3.95 10.1 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
LAB MONITOR, SMART TEMPS SMART LINK 6.0000 1.0000 6.0000 REFRIGERATOR
MOTE-01 9.5000 11.5000 5.2500 WIRELESS TEMPERATURE MONITORING FOR OWNER N/A N/A OWNER
TEMPERATURE REFRIGERATORS/FREEZERS. USED ALONG WITH SMART LINK AND
SMART COMMAND CENTER.
1.0000 2.0000 2.0000 24.0000 24.0000 40.0000 120.0000 60.0000 2.0000
ALCOVE Pump, Suction/Aspirator, SSCOR, Inc 6401.0000 1.0000 1.0000 1.0000 CART PSAS-01 35.0000 22.0000 45.7500 OWNER N/A OWNER
General, Potable
ALCOVE DEFIBRILLATOR, AED ZOLL MEDICAL CORPORATION AED PLUS 1.0000 1.0000 1.0000 1 ea. SEMI-RECESSED WALL DEAE-01 19.0000 27.0000 40.7000 81.0000 115.0000 60.0000 0.5000 AED PLUS WITH AED COVER; INCLUDES: LCD SCREEN SHOWING OWNER CONTRACTOR BLOCKING, CONDUIT OWNER
CABINET (9320-0723) VOICE PROMPT MESSAGES, DEVICE ADVISORY MESSAGES,
ELAPSED TIME, SHOCK COUNT AND CHEST COMPRESSION GRAPH;
SUPPLIED WITH PUBLIC SAFETY PASS COVER, SOFTCASE,
OPERATOR'S GUIDE; (5) FIVE YEAR LIMITED WARRANTY.
ALCOVE MONITOR, VITAL SIGNS WELCH ALLYN CONNEX SPOT 73MT-B 2.0000 1.0000 2.0000 1 ea. POWER MANAGEMENT STAND MOVS-01 22.0000 36.0000 40.0000 120 60 2 CONNEX SPOT MONITOR WITH BLUETOOTH CAPABILITY, BLOOD OWNER CONTRACTOR CONDUIT OWNER
STAND (7000-APM); 2 ea. PRESSURE, MASIMO SPO2 AND SURETEMP THERMOMETER.
BLOOD PRESSURE CUFF,
SMALL ADULT, 1 TUBE
(REUSE101HP); 2 ea. BLOOD
PRESSURE CUFF, ADULT, 1
TUBE (REUSE111HP); 2 ea.
BLOOD PRESSURE CUFF, LG
ADULT, 1 TUBE (REUSE121HP)
ALCOVE Cart, Procedure, Harloff Company, Inc 6401 1 1 1 FLOOR CASU-03 35 22 45.75 6 DRAWER, CARDIAC BOARD AND BRACKETS, DROP SHELF, UTILITY
Resuscitation HOOKS IV POLE, OXYGEN TANK HOLDER -D/E SIZE
ALCOVE ELECTROCARDIOGRAPH GE HEALTHCARE MAC 5500 HD 1.0000 1.0000 1.0000 1 ea. MAC 5500 HD W/ CAMHD CART ELEC-01 20.1300 16.5600 12.0000 34.0000 120.0000 60.0000 13.4000 MAC 5500 HD ELECTROCARDIOGRAPH SYSTEM. DIMENSIONS OF OWNER CONTRACTOR CONDUIT OWNER
AND COLOR (2053900-013); 1 TROLLY 19WX27DX37H
ea. STANDARD PAPER
PACKAGE (2053900-021); 1 ea.
ENGLISH LANGUAGE
(2053900-023); 1 ea. NORTH
AMERICAN POWER CORD
1 09/07/2018 ISSUED FOR BID
(2053900-069); 1 ea. CAM HD
AHA (2053900-114); 1 ea.
MOBILE LINK WIRELESS WITH
No. Date Issue
NEW TROLLEY BRACKET
(2053900-128); 1 ea. MODULAR
MAC TROLLEY FOR 5500
(2055478-001)
WHEEL CHAIR WHEELCHAIR MEDLINE INDUSTRIES, INC. EXCEL 22" WIDE 1.0000 1.0000 1.0000 FLOOR WHEE-01 32.9000 34.0000 66.8000 120.0000 60.0000 15.0000 EXCEL WHEELCHAIR, SEAT IS 22" W X 18"D, NAVY. WT CAPACITY 500 OWNER N/A N/A OWNER
ALCOVE LBS. TO INCLUDE TELESCOPING IV POLE, OXYGEN TANK HOLDER,
TINNERMAN NUTS FOR LEG RIGGING. DIMENSIONS APPROXIMATE
WHEN FOLDED. Project Number 15849
1.0000 1.0000 1.0000 19.7000 12.2000 31.6000 14.3000
BREAK ROOM MICROWAVE PANASONIC - CONSUMER NE-1054F 1.0000 1 1 COUNTERTOP
MICR-01 20.13 16.56 12 34 120 60 13.4 1000 WATT COMMERCIAL MICROWAVE OVEN; 0.8 CU. FT.; 10 OWNER CONTRACTOR CONDUIT OWNER
ELECTRONICS PROGRAMMABLE MEMORY PADS, "GRAB & GO", DOOR HANDLE AND Drawn S. DENNY
BOTTOM ENERGY FEED, STAINLESS STEEL FINISH, 10
PROGRAMMABLE MEMORY, PADS AND 20 MEMORY CAPABILITY.
BREAK ROOM REFRIGERATOR
FREEZER, UPRIGHT
GE APPLIANCES GTE21GSHSS 1 1 1 FLOOR REFU-01 32.9 34 66.8 120 60 15 21.2 CU. FT. FROST FREE REFRIGERATOR WITH TOP FREEZER AND
UPFRONT TEMPERATURE CONTROLS; 2 GLASS SHELVES; 3 BINS;
OWNER CONTRACTOR CONDUIT OWNER
Checked K. BOYER
DOOR BIN HOLDS GALLON SIZE CONTAINERS. CLEAR
VEGETABLE/FRUIT CRISPERS. ICE MAKER OPTIONAL.
REFRIGERATOR CAPACITY: 15.1 CF; FREEZER CAPACITY: 6.1 CF. Proj. Arch./Eng. K. SCHUSTER
BREAK ROOM WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1.0000 1.0000 1.0000 FLOOR WARE-01 15.9500 3.9500 10.1000 14.3 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
BREAK ROOM Coffee Maker, Single Cup Keurig, Inc. B200 2.0000 1.0000 2.0000

SOILED STORAGE GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 6.0000 1.0000 6.0000 WALL GLBH-01 15.95 3.95 10.1 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/

SOILED STORAGE TRUCK/ BIN, WASTE RUBBERMAID COMMERCIAL 4608 1.0000 1.0000 1.0000 1 ea. DOMED HINGED LID (4615) FLOOR TRBW-01 26 38 28
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
TRUCK/BIN TO HOLD 8 CF.; 5300 LB CAPACITY, SMOOTH ALL PLASTIC OWNER N/A N/A OWNER
Provident Hospital - Renal
SOILED STORAGE Cart/Truck, Soiled Utility
PRODUCTS

Rubbermaid Commercial Products 4608 Cube Truck (8 cu. 1.0000 1.0000 1.0000 FLOOR CATS-01 60.0000 24.0000 79.0000
BODY; METAL FRAME DESIGN, 5" CASTERS--2 FIXED, 2 SWIVEL.
SPECIFY COLOR WHEN ORDERING- AVAILABLE IN DB,G,R,W,Y Dialysis Center
Ft., Black)
2.0000 1.0000 2.0000 48.0000 24.0000 72.0000
STORAGE Headphones TBD TBD 1105.0000 6 1 6 38.0000 85.0000 34.0000
STORAGE Stand, IV, Chrome Brewer Company 11360 (5leg,4-hook) 1.0000 1.0000 1.0000 FLOOR IVST-01
STORAGE CART, SUPPLY INTERMETRO INDUSTRIES CORP. / 1.0000 1.0000 1.0000 FLOOR CASU-01 60 24 79 WIRE CART SUPPLY CART; QTY 4 OWNER N/A N/A OWNER
METRO INTERNATIONAL

STORAGE CART, SUPPLY INTERMETRO INDUSTRIES CORP. / 1.0000 1.0000 1.0000 FLOOR CASU-02 48 24 72 WIRE CART WITH (5) SHELVES; BOTTOM SHELF TO BE SOLID; SIDE OWNER N/A N/A OWNER
METRO INTERNATIONAL AND BACK ENCLOSURE PANELS; DONUT BUMPERS; WITH TWO
SWIVEL CASTERS AND TWO CASTERS WITH BRAKES.
STORAGE STRETCHER STRYKER 5 WHEEL 30" 1105 1.0000 1.0000 1.0000 FLOOR STRT-02 38 85 34

STORAGE WHEELCHAIR, BARIATRIC MEDLINE INDUSTRIES, INC. MDS809750 1.0000 1.0000 1.0000 FLOOR WHBA-01 SHUTTLE BARIATRIC WHEELCHAIR, SEAT WIDTH 26". ELEVATING OWNER N/A N/A OWNER
LEGS. REMOVEABLE DESK LENGTH ARMS. 850 LB WEIGHT CAPACITY.
2.0000 1.0000 2.0000 8.0000
RECEPTION PC COMPUTER WITH TBD TBD TBD 1.0000 1.0000 1.0000 CTRTP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE
AND MOUSE
RECEPTION Copier, Printer, Multifunction Canon USA, Inc Image Runner 1630 1.0000 1.0000 1.0000 FLOOR COPM-01
RECEPTION Bin, Shredding, Secure Shred-it, Inc. Standard Console 1.0000 1.0000 1.0000 CTRTP BINS-01
MEETING ROOM PC COMPUTER WITH
MONITOR, KEYBOARD,
TBD TBD TBD 1.0000 1.0000 1.0000 8 CTRTP OWNER CONTRACTOR CONDUIT, CABLES,
FACE PLATE
OWNER 430 East 51st Place
CONFERENCE
AND MOUSE
AV CABINET TBD TBD TBD 1.0000 1.0000 1.0000 FLOOR CAV-01
Chicago, Illinois 60615
SOCIAL WORKER PC COMPUTER WITH TBD 2955.0000 TBD 1.0000 4.0000 4.0000 CTRTP 11.4000 8.2500 12.0000 OWNER CONTRACTOR CONDUIT, CABLES, OWNER
OFFICE MONITOR, KEYBOARD, FACE PLATE
AND MOUSE
STAFF OFFICE PC COMPUTER WITH TBD TBD TBD 1.0000 4.0000 4.0000 CTRTP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE Project Name
AND MOUSE
CLINIC MANAGER PC COMPUTER WITH TBD TBD TBD 1 1 1 CTRTP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE
AND MOUSE
DIETICIAN OFFICE PC COMPUTER WITH
MONITOR, KEYBOARD,
AND MOUSE
TBD TBD TBD 1.0000 1 1 CTRTP DELL, VOSTRO MINI TOWER & E1911-19" MONITOR OWNER CONTRACTOR CONDUIT, CABLES,
FACE PLATE
OWNER
OWNER EQUIPMENT SCHEDULE
OFFICES WASTE RECEPTACLE RUBBERMAID COMMERCIAL 2955 1.0000 4 4 FLOOR WARE-02 11.4 8.25 12 SMALL DESKSIDE, 8 GAL, BIEGE OWNER N/A N/A OWNER
PRODUCTS
VARIOUS Clock, Analog, Wall Primex Wireless Traditional 12.5"/Black 1 4 4 WALL OWNER CONTRACTOR BLOCKING CONTRACTOR
[14155]

JANITORS CLOSET BUCKET, MOPPING RUBERMAID COMMERCIAL Q950 - HYGEN 1 FLOOR


PRODUCTS Microber Charging Sheet Name
Bucket
JANITORS CLOSET CART, HOUSEKEEPING, GEERPRES INC ESCORT RX 3661 1 FLOOR

Q1-1
STAINLESS

WATER
TREATMENT ROOM
Water Treatment System MarCor CONTRACTOR CONTRACTOR CONDUIT, CABLES,
PIPING, EQUIP PADS,
CONTRACTOR Drawing No.
BLOCKING
ARCHITECTURAL ABBREVIATIONS LIST MATERIAL DESIGNATIONS ARCHITECTURAL SYMBOLS LIST SPECIFIC SYMBOL LIST
DRAWING TITLE FLOOR ELEVATION TARGET THE SYMBOLS BELOW APPLY TO ALL ARCHITECTURAL DRAWINGS :
EARTH/ COMPACT FILL
A E L R
DRAWING NUMBER 200 LEVEL FIRE EXTINGUISHER (F.E.) & CABINETS: NOTE: CONTRACTOR TO COORD. &
AB ANCHOR BOLT E EAST L LENGTH R RISER
GRAVEL/ POROUS FILL 200'-0"
ABV ABOVE EA EACH LAB LABORATORY RAD RADIUS DRAWING TITLE PROVIDE WOOD BLOCKING FOR ALL
A/C AIR CONDITIONING EB EXPANSION BOLT LAM LAMINATE(D) RB RUBBER BASE BUILDING DATUM ELEVATION CP
FE-01 RECESSED CABINET W/ FIRE EXTINGUISHER ITEMS LISTED BELOW
ACC
ACT
ADA
ACCESSIBLE
ACOUSTICAL TILE
AMERICANS WITH DISABILITIES
EC
EL
ELEC
EXPOSED CEILING
ELEVATION
ELECTRIC(AL)
LAT
LAV
LB
LATERAL
LAVATORY
POUND(S)
RD
REV
RECP
ROOF DRAIN
REVISION, REVISE(D)
RECEPTACLE
ROCK
1 View Name
A6-2 1 1/2" = 1'-0" [REF: 1/ A4-1] REFERENCE WORK POINT TARGET
(SEE 3/A6-1 FOR MOUNTING HEIGHT)

ADD ADDENDUM ELEV ELEVATOR LBL LABEL REF REFERENCE CONCRETE: CAST IN PLACE/ PRECAST
ADD'L ADDITIONAL EMER EMERGENCY LH LEFT HAND REFL REFLECT(ED), (ING) BACK REFERENCE TARGET
LOCATION (I.E. REFER TO 1/A4-1 TACK BOARDS:
ADJ ADJUSTABLE ENCL ENCLOSE (URE) LIB LIBRARY REINF REINFORCE(D), (ING) SAND/ MORTAR/ PLASTER
AFF ABOVE FINISHED FLOOR ENG ENGINEER LIN LINEAR REQD REQUIRED FOR TARGET 1/A6-2 LOCATION) MAJOR REFERENCE WORK
POINT TO LOCATE
TB-3 3'-0" (W) X 4'-0" (FIXED) NOTE: MOUNT ALL CHALK, MARKER,
ALT ALTERNATE EQ EQUAL LL LIVE LOAD RFI REQUEST FOR INFORMATION DRAWING SCALE AND TACK BOARDS SO THAT TOP
ALUM ALUMINUM EQUIP EQUIPMENT L.P. LOW POINT RH RIGHT HAND CONCRETE MASONRY UNIT DIMENSIONS TB-4 4'-0" (W) X 4'-0" (FIXED) EDGES ALIGN WITH TOP EDGE OF Department of Capital Planning & Policy
AP ACCESS PANEL EWC ELECTRIC WATER COOLER LT LIGHT RM ROOM SHEET NUMBER
APPD APPROVED EXP EXPOSED LTG LIGHTING RO ROUGH OPENING
REVISION TARGET ADJACENT DOOR HEADS Bureau of Asset Management
COMMON/ FACE BRICK NORTH ARROWS
APPROX APPROXIMATE EXH EXHAUST LTL LINTEL MARKER BOARDS: Notice: This drawing has not been published and is the
EXIST EXISTING N REVISION DESIGNATION sole property of Cook County. It is loaned to the borrower
ARCH ARCHITECT(URAL) LVR LOUVER
AUD AUDITORIUM EXP EXPANSION CUT STONE 1 MB-3 3'-0" (W) X 4'-0" (FIXED) for their confidential use only. In consideration of the loan
EXT EXTERIOR TRUE NORTH ARROW REVISION CLOUD of this drawing, the borrower promises and agrees to
AUTH AUTHORIZED
AUTO AUTOMATIC M S MARBLE
MB-4 4'-0" (W) X 4'-0" (FIXED) return it upon request and agrees that it shall not be
A/V AUDIO/VISUAL reproduced, copied, loaned, or otherwise disposed of
M METER(S) S SOUTH directly or indirectly, nor used for any purpose other than
PROJECT NORTH ARROW
F MACH MACHINE SAFB SOUND ATTENUATION FIRE STEEL COATHOOKS: NOTE: COAT HOOKS LOCATED ON A for which it is furnished, in whole or part.
MAN MANUAL BLANKET ALIGN
FAST FASTENER SEE 4/A6-1 FOR MOUNTING DETAILS. WALL BEHIND A DOOR ARE TYP. 1'-3"
MAS MASONRY SAN SANITARY
FD FLOOR DRAIN ALUMINUM COLUMN LINE GRID & NUMBERS FROM THE CORNER U.N.O.
B FE FIRE EXTINGUISHER
MAT'L MATERIAL(S) SC SEALED CONCRETE
CH-4 (1) 2'-0"(L) PANEL W/ (4) COATHOOKS
MAX MAXIMUM SCHED SCHEDULE NEW COLUMN NUMBER
B/ BOTTOM OF FEC FIRE EXTINGUISHER CABINET
MB MARKER BOARD SEC SECOND ROUGH WOOD
BEL BELOW FFL FINISH FLOOR LINE L CH-12 (1) 8'-0"(L) PANEL W/ (12) COATHOOKS
MECH MECHANICAL SECT SECTION
BTWN BETWEEN FHC FIRE HOSE CABINET FIRE-RATED WALL SYMBOLS
MED MEDIUM SERV SERVICE EXISTING COLUMN NUMBER
BEV BEVELED FHMS FLATHEAD MACHINE SCREW FINISH WOOD
MEMB MEMBRANE SF SQUARE FOOT MISC DEVICE LOCATIONS:
BLKG BLOCK(ING) FHWS FLATHEAD WOOD SCREW
MTL METAL SGL SAFETY GLASS
X
BLDG BUILDING FIN FINISH(ED) 1 HR RATED WALL
MEZZ MEZZANINE SHT SHEET PLYWOOD
BM BEAM FLG FLASHING TV-1 TELEVISION (SEE A6-1 FOR MOUNTING HEIGHT)
MFR MANUFACTURE(R), (ED) SIM SIMILAR
BOT BOTTOM FLR FLOOR(ING) 2 HR RATED WALL
MI MILE(S) SK SKETCH SECTION TARGET
BRG BEARING FLUOR FLUORESCENT PARTICLE BOARD TV-2 CONFERENCE ROOM MONITOR (SEE A6-1 FOR MOUNTING HEIGHT)
MIN MINIMUM S.J. SEALANT JOINT
BRK BRICK FR FRAME(D), (ING) BUILDING SECTION TARGET
MISC MISCELLANEOUS SPEC(S) SPECIFICATION(S) PANIC BUTTON (MOUNTED IN MILLWORK)
BS BOTH SIDES FS FULL SIZE X
3 HR RATED WALL PB-1
MO MASONRY OPENING SQ SQUARE BATT INSULATION
BSMT BASEMENT FT FOOT (FEET) AX-X
MTD MOUNTED SSK SERVICE SINK SECTION NUMBER
BTU BRITISH THERMAL UNIT FTG FOOTING
MULL MULLION SST STAINLESS STEEL WALL SYMBOLS
BUR BUILT-UP ROOFING FUR FURRED, FURRING RIGID INSULATION SHEET NUMBER
FUT FUTURE STD STANDARD
FV FIELD VERIFY STIFF STIFFENER
STL STEEL SPRAYED-ON FIREPROOFING NEW DOOR
X DETAIL SECTION TARGETS
STOR STORAGE
C STRUCT STRUCTURE, STRUCTURAL
AX-X
SECTION NUMBER EQUIPMENT & FURNISHINGS SCHEDULE
C CENTER G N SUSP SUSPEND, SUSPENDED SEALANT WITH BACKER ROD
EXISTING DOOR
SHEET NUMBER Type Mark Description Count
CAB CABINET N NORTH SYM SYMMETRY, SYMMETRICAL X
G GRAM
CAP CAPACITY NAT NATURAL GYPSUM DRYWALL AX-X
GA GAGE, GAUGE ACCESS PANEL @ 6' AFF TYP. BINS-01 BIN, SHREDDING, SECURE 1
CEM CEMENT NC NO CEILING
GALV GALVANIZED
CER CERAMIC NIC NOT IN CONTRACT CASU-01 CART, SUPPLY 6
GC GENERAL CONTRACTOR METAL LATH WITH PLASTER DETAIL TARGET
CFT CUBIC FOOT (FEET) NO. NUMBER T NEW GLASS PARTITION CASU-02 CART, SUPPLY 2
GD GRADE, GRADING
CG CORNER GUARD NOM NOMINAL CASU-03 CART, PROCEDURE, RESUSCITATION 1
GFR GLASS FIBER REINFORCED T TREAD
CHAM CHAMFER NRC NOISE REDUCTION TERRAZZO DETAIL NUMBER
GFRC GFR CONCRETE T/ TOP OF NEW PARTITION CAV-01 AV CABINET 1
CIR CIRCLE COEFFICIENT
GKT GASKET(ED) T&B TOP & BOTTOM CH-4 COAT HANGER 3
CIRC CIRCUMFERENCE NTS NOT TO SCALE
CJ CONTROL JOINT
GL GLASS, GLAZING TEMP TEMPERATURE GLASS 1 SIM EXISTING PARTITION CH-12 COAT HANGER 1
GPDW GYPSUM DRYWALL TERR TERRAZZO A6-2
CK CAULKING
GT GROUT O T&G TONGUE & GROOVE
COPM-01 COPIER, PRINTER, MULTIFUNCTION 1
CLASSRM CLASSROOM ACOUSTICAL TIL E COSH-01 CONTAINER, SHARPS 6
GWB GYPSUM WALL BOARD OA OVERALL THK THICK(NESS) PARTITION TO BE
CLG CEILING SHEET NUMBER
GYP GYPSUM OC ON CENTER THRU THROUGH DEMOLISHED DEAE-01 DEFIBRILLATOR, AED 1
CLO CLOSET
CLR CLEARANCE/CLEAR OD OUTSIDE DIAMETER TV TELEVISION ELEVATION DI-01 DIALYSIS MACHINE 15
x x x x FENCE
CLS CLOSURE OFF OFFICE TYP TYPICAL TARGET DISE-01 DIAGNOSTIC SET 1
CM CENTIMETER(S) H OH OVERHEAD BUILDING ELEVATION TARGET
DRCL-01 DIALYSIS RECLINER - NIC 12
CMU CONCRETE MASONRY UNIT O.H. OPPOSITE HAND BUILDING MATCH LINE
H HIGH 1 SHEET NUMBER DRCL-02 DIALYSIS BARIATRIC RECLINER - NIC 1
CO CLEAN OUT OHMS OVALHEAD MACHINE SCREW
HB HOSE BIBB
COEF COEFFICIENT HC HOLLOW CORE
OHWS OVALHEAD WOOD SCREW U 4 A4-1 2
DRDU-06 DRUG DISPENSING UNIT 1
OPNG OPENING DETAIL NUMBER ACCESSIBILITY SYMBOLS ELEC-01 ELECTROCARDIOGRAPH 1
COL COLUMN HCAP HANDICAP UC UNDERCUT
COMB COMBINATION HD HEAD
OPP OPPOSITE 5' - 0" EW-01 EYE WASH 3
UL UNDERWRITER'S 3 INTERIOR ELEVATION TARGET
COMP COMPRESS(ED), (ION), (IBLE) HDW HARDWARE LABORATORY WHEELCHAIR TURNING EW-02 EYE WASH, DRENCH HOSE 2
CONC CONCRETE 1 SHEET NUMBER RADIUS Holabird & Root, LLC expressly disclaims any
CONF CONFERENCE
HEX HEXAGONAL P UNEX UNEXCAVATED FE-01 FIRE EXTINGUISHER CABINET 3 responsibility arising from any unauthorized use of these
HM HOLLOW METAL UNO UNLESS NOTED OTHERWISE
CONN CONNECTION
1 A2-1 1 DETAIL NUMBER GLBH-01 GLOVE BOX HOLDER 7 plans, drawings and notes. Any authorization must be in
HORIZ HORIZONTAL PAR PARALLEL UR URINAL
CONST CONSTRUCTION HP HORSEPOWER PBD PARTICLE BOARD HM-01 HEALTH MONITOR DISPLAY 1 writing.
1
CONT CONTINUOUS OR CONTINUE H.P. HIGH POINT PC PRECAST CONCRETE ACCESSIBLE ITEM MICRO-01 MICROWAVE 1
CONTR CONTRACT(OR) HR HOUR P.D. PLAN DETAIL V ROOM NAME & NUMBER TARGET MOVS-01 MONITOR, VITAL SIGNS 1
This drawing copy may have been reproduced at a size
CONV CONVECTOR HT HEIGHT PED PEDESTAL different than originally drawn. The Owner and Architect
VAPB VAPOR BARRIER NARC-01 CABINET, STORAGE, CLINICAL, NARCOTICS 1
COP COPING HTG HEATING PERF PERFORATE(D) assume no responsibility for use of incorrect scale.
VB VINYL BASE WHEELCHAIR AREA REFU-01 REFRIGERATOR FREEZER, UPRIGHT 1
CORR CORRIDOR HVAC HEATING/VENTILATION/AIR PERIM PERIMETER AOR Drawings are not to be scaled.
VCT VINYL COMPOSITE TILE ROOM NAME OF REFUGE
CPT CARPET(ED) CONDITIONING PERP PERPENDICULAR 101 REUN-01 REFRIGERATOR, UNDERCOUNTER 3
VERT VERTICAL
CRW CURTAIN WALL HW HOT WATER PKG PARKING ROOM SCHT-01 SCALE, HEIGHT 1 Not published - All rights reserved.
VEST VESTIBULE
CS COUNTERSINK HYD HYDRAULIC PL PLATE VIF VERIFY IN FIELD NUMBER SCI-01 SCALE, INTEGRATED 1
CSMT CASEMENT WHEELCHAIR CLEAR
P.L. PROPERTY LINE VT VINYL TILE DOOR TARGET FLOOR AREA STWB-01 STOOL WITH BACK 1
CT CERAMIC TILE I PLAM PLASTIC LAMINATE
CW COLD WATER PLAS PLASTER TAEP-01 EXAM TABLE POWE 1
ID INSIDE DIAMETER
CY CUBIC YARDS
IN INCH(ES) PLBG PLUMBING W 101A ELECTRICAL CONTROL ON DOOR TB-03 TACK BOARD 1
PNL PANEL DOOR NUMBER, (COORDINATE WITH ELECTRICAL DRAWINGS) TB-04 TACK BOARD 1
INCL INCLUDE(D), (ING) W WEST SEE DOOR SCHEDULE
INFO INFORMATION PNT PAINT(ED) TV-01 WALL MOUNTED TV 3
W/ WITH ACCESS BUTTON FOR AUTOMATIC
INSUL INSULATION POL POLISH(ED) PARTITION TYPE TARGET A
WC WATER CLOSET DOOR. ALL DOOR FRAMES WITH TV-02 WALL MOUNTED MONITOR 2
D INT INTERIOR PR PAIR
WD WOOD ACCESS BUTTON TO BE TVAR-01 TV ARM, ARTICULATING 12
INTERM INTERMEDIATE PREFAB PREFABRICATED PARTITION TYPE,
D DEPTH WIN WINDOW D1.1 ELECTRIFIED WHEE-01 WHEELCHAIR 1
PRES PRESSURE S SEE PARTITION TYPES
DB DECIBELS WL WIND LOAD
DBL DOUBLE
J PROJ PROJECTION
W/O WITHOUT A PEDESTAL ACCESS BUTTON FOR
PROT PROTECTION
DEG DEGREE(S) J JOIST WP WATERPROOFING WINDOW TARGET AUTOMATIC DOOR. ALL DOOR
PSI POUNDS PER SQUARE INCH
DEG C DEGREE(S) CELSIUS JAN JANITOR WPT WORKING POINT FRAMES WITH ACCESS BUTTON TO
PT POINT
DEG F DEGREE(S) FAHRENHEIT JC JANITOR'S CLOSET WRSTP WEATHER STRIPPING BE ELECTRIFIED
PTN PARTITION
DEPT DEPARTMENT JCT JUNCTION WT WEIGHT W11 WINDOW TYPE, 1 09/07/2018 ISSUED FOR BID
PVC POLYVINYL CHLORIDE CARD READER ON DOOR FRAME
DET DETAIL JT JOINT WWF WELDED WIRE FABRIC SEE WINDOW SCHEDULE C
PW PAINTED WOOD TO BE ELECTRIFIED OR ON WALL No. Date Issue
DF DRINKING FOUNTAIN
DH DOUBLE HUNG K B101 VIEW WINDOW NUMBER,
RELEASE BUTTON FOR
SEE INTERIOR WINDOW R
DIA DIAMETER KG KILOGRAM(S) Y SCHEDULE AUTOMATIC DOOR (MOUNTED ON
Project Number 15849
DIAG DIAGONAL KIT KITCHEN KEYNOTE TARGET FURNITURE; CONTRACTOR TO
DIM DIMENSION YD YARD
KM KILOMETER(S) COORDINATE WITH FURNITURE Drawn S. DENNY
DIV DIVISION KO KNOCKOUT Q ?
011000.01 KEYNOTE, SEE KEYNOTE LIST SUPPLIER TO CONCEAL ALL
DL DEAD LOAD KS KNEE SPACE WIRING. RUN CONDUIT IN SLAB Checked K. BOYER
QT QUARRY TILE
DN DOWN TO FURNTURE STATION).
QTY QUANTITY Proj. Arch./Eng. K. SCHUSTER
DP DAMP PROOFING TOILET ACCESSORIES TARGET
DR DOOR NEGATIVE PRESSURE MONITOR.
P
DS DOWNSPOUT T1 ALL DOOR FRAMES WITH
DU DWELLING UNIT PRESSURE MONITOR TO BE
DWG DRAWING ACCESSORY NUMBER
ELECTRIFIED.
Provident Hospital - Renal
KEYNOTES LEGEND MASTER LIST KEYNOTES LEGEND MASTER LIST KEYNOTES LEGEND MASTER LIST Dialysis Center

024119.01 REMOVE HM FRAMES & WOOD DOORS 102800.04 GRAB BAR (36")
024119.02 REMOVE METAL STUD AND GBDW WALLS 102800.06 MIRROR - ABOVE COUNTERTOP (SURFACE MOUNTED)
024119.03 REMOVE STEEL SHUTTERS & ASSOCIATED FRAMES & MOTORS 102800.08 PAPER TOWEL DISPENSER
024119.04 REMOVE CMU FOR NEW DOOR 102800.09 SOAP DISPENSER
024119.05 REMOVE ACT FLOORING 102800.10 BABY CHANGING TABLE
024119.06 REMOVE MILLWORK COUNTERTOPS 102800.13 SEMI-RECESSED PAPER TOWEL DISPENSER & WASTE RECEPTACLE; 12-GAL WASTE CONTAINER.
024119.07 REMOVE DOOR & FRAME 122413.01 MANUALLY OPERATED ROLLER SHADES
024119.08 REMOVE FIXED SEATING 224000.01 WATER CLOSET 430 East 51st Place
024119.09 REMOVE VESTIBULE STOREFRONT 224000.02 WATER CLOSET - ACCESSIBLE Chicago, Illinois 60615
024119.10 REMOVE CONC & WOOD PLANTER/SEAT WALL 224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ PIPE COVER
024119.11 REMOVE SUSPENDED ACT CEILING 224000.05 LAVATORY - DROP-IN SINK Project Name
024119.12 REMOVE GBDW SOFFIT 260000.01 DEVICE MOUNTED ON FURITURE. CONTRACTOR TO COORDINATE WITH FURNITURE SUPPLIER TO
024119.13 REMOVE PLASTER CEILING CONCEAL ALL WIRING.
024119.14 REMOVE AND REPLACE ENTRY DOORS
ARCHITECTURAL SYMBOLS &
024119.15 NEW DUCT WORK OPENINGS IN CMU BULKHEAD. SEE MECHANICAL DRAWINGS. USE EXISTING OPENINGS ABBREVIATIONS
WHERE POSSIBLE. PROVIDE NEW LINTELS WHERE NECESSARY.
024119.16 REMOVE DOOR WHILE LEAVING FRAME INTACT. Sheet Name
024119.18 REMOVE EXISTING BOLLARD IN CONFLICT WITH NEW GENERATOR ENCLOSURE.
064116.02
102800.03
PLASTIC LAMINATE LOCKER.
GRAB BAR (42") AND VERTICAL GRAB BAR (18") Drawing No. A1-1
GENERAL NOTES: FLOOR PLANS
1. SEE LS-SERIES DWGS FOR FIRE-RATED PARTITION LOCATIONS.

2. SEE SHEET A7-2 FOR DOOR SCHEDULE.

3. SEE SHEET A7-1 FOR PARTITION TYPES. ALL PARTITION TYPES


ARE D1.1 U.N.O.
S
2
A4-2
4. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS FOR
DIRECTOR JANITOR'S STAFF CHANGING COORD. OF ALL TRADES & SUBS, AND REPORT ANY CONFLICTS
WOMENS MENS OFFICE TELECOM STAFF OR DISCREPANCIES TO THE ARCHITECT.
OFFICE CLOSET TOILET ROOM
107 108 109 111 113
110 112 113B 113A
5. ALL DIMENSIONS ARE LOCATED AT FACE OF FINISH, U.N.O.
A 6. PROVIDE 18" MIN ON LATCH SIDE OF ALL DOORS. ALL DOOR
Department of Capital Planning & Policy
9
122413.01 F9.2 D1.2
S FRAMES TO BE 4" FROM THE CLOSEST PERPENDICULAR Bureau of Asset Management
S 113B 3
A8-3 7 PARTITION, U.N.O.
CONFERENCE D1.2 A6-2 Notice: This drawing has not been published and is the
S
102
064116.02 sole property of Cook County. It is loaned to the borrower
107 108
113A 8 D1.2 SOILED 7. WALLS TO BE FLUSH WITH COLUMN FURRING, U.N.O.
4 CH-4 S for their confidential use only. In consideration of the loan
STORAGE
109 6 110 111 112 113 of this drawing, the borrower promises and agrees to
118 8. PROVIDE BEVELED EDGE STEEL ANGLE PROTECTORS FOR ALL
3 A8-3 1
CORRIDOR return it upon request and agrees that it shall not be
5I 102 PAT. TOILET 1 100B TIME CORRIDOR 100C 5 ITEMS PROJECTING FROM WALL.
F9.2 A8-3 100D reproduced, copied, loaned, or otherwise disposed of
A4-1 114 A6-2 CLOCK 100C A8-1 CLEAN
2 A C D1.2 WATER directly or indirectly, nor used for any purpose other than
CORRIDOR S
SUPPLY 9. MAINTAIN WALL RATING AT RECESSED ITEMS SUCH AS AT
5 118 119 TREATMENT for which it is furnished, in whole or part.
100B 119 EMERGENCY SHOWERS, FIRE EXTINGUISER CABINETS, ETC.
125
114
D1.2
B S MED. PREP. COSH-01 10. PROVIDE MOP SINK WITH WALL GUARD, MOP HOLDER AND
TB-03 115 UTILITY SHELF AT ALL JANITOR CLOSETS.
FE-01 12 6
EXAM F9.2 FE-01 A8-1
COSH-01 D1.2 11. FOR ALL EQUIP. AND EQUIP. BASES IN MECH ROOMS AND OTHER
106 1 S
A4-1 2 106 AREAS SEE THE SPECIFIC ENGINEERING DWGS & SPEC (COORD.
EQUIP. SIZE OF BASES WITH SPECIFIC EQUIP. MFR).
11 TB-04 260000.01 R 11 REPAIR
FOR DOOR 100B D1.4 120 125A
1 S 12. PROVIDE FIBERGLASS GPDW AT WET WALL LOC.
A4-2
A8-3 10
1 5
NURSE 6 A8-2 3
2 A8-2
STATION D1.2 NEW CMU INFILL TO
WAITING S 120 13. MOVABLE FURNITURE IS SHOWN DASHED. FIXED OR BUILT-IN
MATCH EXISTING AT
ROOM MIRROR FURNITURE IS SHOWN SOLID.
D1.4 EXISTING OPENING
101 S 10
A D5.1 FE-01 14. PROVIDE GPDW TRIMLESS ACCESS PANELS (2'-0" X 2'-0") FOR
C 100A.B
1 3
S 4 125B
GPDW CEILING AREAS. MINIMIZE NEED FOR ACCESS PANELS -
A8-1 D1.2 A8-1
S
121 COORD. LOCATION OF ACCESS PANELS WITH OTHER TRADES
A 4 STORAGE 6 Sim FOR ITEMS ABOVE CEILING.
105 126
RECEPTION A C
3 122 LAB 100D A4-1
105 A8-2 9 121 15. FOR STEEL LINTELS AT INTERIOR MASONRY WALLS &
064116.02 2 A8-1 122
100A.A 103 104
4 A8-1 P PARTITIONS - SEE CMU LINTEL SCHEDULE. VERIFY MASONRY
VESTIBULE 2
117 123 124 WALL WIDTH & CLEAR SPAN (OPENING WIDTH). PROVIDE
100A APPROPRIATE LINTEL AND COORD. WITH OTHER TRADES.
6 7 117A 2
A 8 127
A6-2
D1.2 16. FILL ALL SLAB PENETRATIONS WITH FIRESTOPPING MATERIAL
F9.2 F9.2 5 S
(SEE SPEC.)
122413.01 F9.2 F9.2 D40.2
S
17. COORDINATE ALL FIRE EXTINGUISER CABINETS INTO GPDW
D PARTITIONS.
DIETITIAN SOCIAL TREATMENT PRIVATE W.C. ELECTRICAL MECHANICAL
103 WORKER AREA 117A 123 124 18. PROVIDE SHADES AT ALL INT. AND EXT. WINDOWS, U.N.O.
PAT./ISOLATION
104 1 116 117
19. ALL H.M. DOORS & H.M. FRAMES TO BE PAINTED.
1 A4-1 2 3
20. ALL UNFINISHED GPDW (NOT PTD. OR WITH WALLCOVERING) TO
BE TAPED AND SANDED.

1
A2-1
100 LEVEL PLAN
1/8" = 1'-0"
21. ALL PAINTED WALLS TO HAVE SATIN PAINT FINISH.
ALL PAINTED CEILINGS TO BE FLAT PAINT FINISH.

22. REFER TO CEILING PLANS FOR SPECIFIC CEILING LAYOUTS AND


HEIGHTS.

23. ALL EXT. STEEL TO BE GALVANIZED AND PTD. (U.N.O.).

24. UNLESS NOTED SPECIFICALLY ON DWGS ALL WOOD


BLOCKING, STEEL ANGLES, MISC. STEEL PLATES, ETC. ARE Holabird & Root, LLC expressly disclaims any
TO BE CONT. responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
25. GC TO COORD. WOOD BLOCKING FOR WALL-MOUNTED ITEMS writing.
SUCH AS MILLWORK, MARKERBOARDS, TOILET ACCESSORIES,
HANDRAILS, ETC. This drawing copy may have been reproduced at a size
JANITOR'S different than originally drawn. The Owner and Architect
CLOSET 26. GC TO COORD. WOOD BLOCKING FOR CEILING-MOUNTED ITEMS assume no responsibility for use of incorrect scale.
112 CHANGING
1'-8" SUCH AS PROJ. SCREENS, CURTAIN TRACK, ETC. Drawings are not to be scaled.
6'-5 1/2" 6'-6 1/4" 7'-1 3/4" 5'-4 1/2"
ROOM
113A
27. FOR LARGE OPENINGS IN FLOORS AND WALLS SEE STRUCT. Not published - All rights reserved.
DWGS. FOR CONCRETE & STRUCT INFILLS. FOR SMALL
A STAFF OPENINGS IN FLOOR SLABS, EITHER FILL WITH FIRESTOPPING

5'-1 1/2"
WOMENS MENS TOILET MATERIALS (SEE SPEC.) OR CONCRETE.
DIRECTOR STAFF

7'-7"
107 108 OFFICE TELECOM 113B
OFFICE 113
109 111 28. SEE ENLARGED PLANS AND SECTIONS FOR COORESPONDING
110
INFORMATION

29. SEE ID SHEETS FOR CORNER GUARDS.


3'-0" 2'-11" 3'-3"

5"
PAT. TOILET CORRIDOR CORRIDOR
6'-0"

100D 5'-9"
CONFERENCE 114 7" 5'-8" 100C
13'-0" 4'-11" SYMBOLS: FLOOR PLAN
102 CORRIDOR 10" 10"
100B SEE SHEET A1-1 FOR ADDITIONAL SYMBOLS AND ABBREVIATIONS
5'-0 1/2"

3'-0"
10"

7'-7" 2'-11 1/2" 1'-11 1/2"


B MED. PREP.
10'-4"

1'-0"
2'-9"

12'-0 1/2"
CLEAN
10"

115 SOILED NEW DOOR


4'-1"

1'-9" 2'-6" 2'-6" 2'-7" 12 STORAGE SUPPLY


10" 119
9'-5118
1/2"
1 09/07/2018 ISSUED FOR BID
1 2'-0" 10" EXISTING DOOR
3'-8" 4'-1 1/4" 3'-5"

2'-0" No. Date Issue


WATER
WAITING
11 TREATMENT NEW GLASS PARTITION
ROOM 2'-1" 8'-0" 2'-1" 10"
125
11'-0"

101 EXAM EQUIP.


NURSE

8'-7"
106 Project Number 15849
2 STATION REPAIR NEW PARTITION
1'-1 1/4"

120 Drawn S. DENNY


10" 10"
3'-7 1/2" 4'-6 1/4"

10 EXISTING PARTITION TO REMAIN Checked K. BOYER


LAB
7'-5 1/2"

C Proj. Arch./Eng. K. SCHUSTER

7'-7"
RECEPTION 3 121
10"

NOT IN SCOPE OF WORK (N.I.C.)


105 14'-11" 9'-5 1/2"
STORAGE
4'-5 1/2"

VESTIBULE 8'-0"
TREATMENT 2'-7" 122
9 CASEWORK / MILLWORK
5'-2"
100A AREA 5" 3'-9" 2'-9" 2'-9" 2'-10"
4 116 Provident Hospital - Renal
3'-2" 3'-1" 3'-0" 5"

D1.1 NON RATED PARTITION TYPE,


6 7 8
W.C. S
SEE PARTITION TYPES Dialysis Center
117A
11'-3"

SOCIAL PRIVATE D1.1 RATED PARTITION TYPE,


ELECTRICAL MECHANICAL
WORKER 5 PAT./ISOLATION S SEE PARTITION TYPES
123 124
104 117
10"

D KEYNOTES LEGEND
DIETITIAN 1'-3" 9'-6 1/2" 29'-10" 12'-1" 5'-8 1/2"
REF#
103 064116.02 PLASTIC LAMINATE LOCKER.
122413.01 MANUALLY OPERATED ROLLER SHADES
1 2 3 260000.01 DEVICE MOUNTED ON FURITURE. CONTRACTOR TO
COORDINATE WITH FURNITURE SUPPLIER TO CONCEAL 430 East 51st Place
ALL WIRING. Chicago, Illinois 60615

2
A2-1
100 LEVEL DIMENSION PLAN
1/8" = 1'-0"
Project Name

100 LEVEL FLOOR PLAN &


*SEE Q SERIES FOR OWNER
DIMENSION PLAN
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS Sheet Name

Drawing No. A2-1


GENERAL NOTES: ROOF PLAN
1. SHAFT WALLS TO BE 2-HR RATED.

2. COORDINATE ALL OPENINGS AND PENETRATIONS WITH


RELATED MECH. & STRUCT. DOCUMENTS. ROOFING AT
OPENINGS & PENETRATIONS TO BE INSTALLED PER
MANUFACTURER'S RECOMMENTATIONS.

3. INSULATION HEIGHT TO BE MIN. R-20.0 c.i. (PER ICC IECC 2009


ENERGY CODE) ON ROOF STRUCTURE (ROOF STRUCTURE TO
HAVE 1/4" PER 1'-0" SLOPE).

4. VERIFY TOP OF INSUL. & PARAPET IN FIELD.

5. ALL SPOT ELEVATIONS ARE TAKEN FROM THE ROOF LEVEL


(T.O. DECK AT LOW POINT).
Department of Capital Planning & Policy
Bureau of Asset Management
6. ALL TAPERED INSULATION FINAL SLOPE 1/4" MINIMUM.
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
7. EXISTING ROOFING TO REMAIN. PATCH AS REQUIRED FOR
for their confidential use only. In consideration of the loan
INSTALLATION OF NEW ROOF TOP EQUIPMENT. SEE MEP
of this drawing, the borrower promises and agrees to
DRAWINGS
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
SYMBOLS: ROOF PLAN directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

LOCATION OF EQUIPMENT CURB, COORDINATE


W/ MECH. DWGS

EXISTING ROOF TO REMAIN

ROOF CRICKETS, 1/2" / FT. TAPERED INS., TYP.

H.P. HIGH POINT


1 2 2 3
A4-2 L.P. LOW POINT

RIDGELINE (RL)

SLOPE 1/4" / FT, U.N.O.

A DS DOWNSPOUT

EXISTING
MECHANICAL
UNIT
EXISTING ROOF
HATCH TO REMAIN

A4-1 2
EXISTING SKYLIGHTS
TO REMAIN
1
A4-2

Holabird & Root, LLC expressly disclaims any


responsibility arising from any unauthorized use of these
C plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


EXISTING ROOFING, different than originally drawn. The Owner and Architect
DRAINS, EQUIPMENT assume no responsibility for use of incorrect scale.
TO REMAIN U.N.O. Drawings are not to be scaled.

Not published - All rights reserved.

A4-1

1
A2-3
ROOF PLAN
1/8" = 1'-0"
1 09/07/2018 ISSUED FOR BID
No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
26K7 Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center
L4x4x3/8

L4x4x3/8

430 East 51st Place


DECK OPENING DIMENSIONS Chicago, Illinois 60615
AND LOCATION ON ROOF TO
MATCH MEP DRAWINGS
Project Name

ROOF PLAN
26K7

2 TYP. FRAMING/JOIST FOR METAL DECK OPENING


Sheet Name

A2-3 N.T.S.
Drawing No. A2-3
GENERAL NOTES: REFLECTED CEILING PLANS
NOTES BELOW APPLY TO ALL CEILING PLANS:

1. CEILING GRID TO BE CENTERED IN ROOMS AS SHOWN, U.N.O.

2. DOWNLIGHTS TO BE CENTERED IN CEILING PANELS.

3. ALL GPDW CEILINGS & SOFFITS ARE 5/8" GPDW, U.N.O. - ALL
VERTICAL FACES OF SOFFITS ARE GPDW, U.N.O.

4. COORDINATE ALL MECH. DUCT WORK, PIPING, SPRINKLER


1 2 2 3 LINES & CABLE TRAY TO AVOID CONFLICTS WITH LIGHTS &
A4-2 STRUCTURE.

5. PROVIDE GPDW TRIMLESS ACCESS PANELS (2'-0" X 2'-0") FOR Department of Capital Planning & Policy
DIRECTOR JANITOR'S STAFF CHANGING GPDW CEILING AREAS. MINIMIZE NEED FOR ACCESS PANELS -
TELECOM STAFF
WOMENS MENS OFFICE OFFICE CLOSET TOILET ROOM COORD. LOCATION OF ACCESS PANELS WITH OTHER TRADES Bureau of Asset Management
FOR ITEMS ABOVE GPDW CEILING. Notice: This drawing has not been published and is the
A TYP
4 sole property of Cook County. It is loaned to the borrower
A9-1 6. SEE ELEC. DRAWINGS FOR SPECIFIC LIGHT FIXTURE TYPES, for their confidential use only. In consideration of the loan
N.C. 8' - 6" EXIT SIGNS, VISUAL ALARMS, ETC. of this drawing, the borrower promises and agrees to
8' - 6" return it upon request and agrees that it shall not be
8' - 0" 8' - 0" 7. SEE MECH. DRAWINGS FOR SPECIFIC MECH. DIFFUSERS. reproduced, copied, loaned, or otherwise disposed of
CORRIDOR
8' - 0" 8' - 0" 12' - 0" 12' - 0" 12' - 0" directly or indirectly, nor used for any purpose other than
SOILED
8. FOR CEILING HEIGHT CHANGES PROVIDE 5/8" GPDW FASCIA & for which it is furnished, in whole or part.
STORAGE
CONFERENCE SOFFIT (3 1/4" WIDE) U.N.O.
9' - 6" 9' - 6" 9' - 6" 12' - 0"
PAT. TOILET 7' - 6" 9. SEE MECH. DRAWINGS FOR SPECIFIC MECH. DIFFUSERS.
WINDOW POCKET
CLEAN WATER
MED. PREP. TREATMENT 10. SEE FIRE ALARM DRAWINGS FOR SPRINKLER DATA.
TYP SUPPLY
4
B A9-1 11. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER
8' - 0" 9' - 6" 9' - 6"
8' - 0" ENGINEERING DRAWINGS FOR LOCATION OF LIGHT FIXTURE
7' - 6" 8' - 6"
PLACEMENT.
6 Sim
A9-1 8' - 6" 1 N.C. 12. IN AREAS OF 2'x2' CEILING PANEL WHERE LESS THAN 4"
A9-1 WOULD BE REQUIRED TO FILL SPACE TO WALL, PROVIDE
8' - 6" 7' - 6" EQUIP. MATCHING 2'x4' PANEL & CUT DOWN TO TAKE UP 4" SPACE(DO
1 9' - 6" NURSE REPAIR NOT PROVIDE INTERVENING TEE GRID).
A4-2 STATION 7' - 6"
Sim
WAITING 1 9' - 6"
ROOM A9-1
10' - 0"
EXAM STORAGE LAB
C
9' - 6"
4 9' - 6" SYMBOLS: REFLECTED CEILING PLANS
A9-1 9' - 6"
8' - 0" 12' - 0"

9' - 6" 2'x2' ACOUSTICAL LAY-IN


PANELS
RECEPTION
8' - 6"
VESTIBULE TYP
4
A9-1 N.C. N.C. 2'x4' ACOUSTICAL LAY-IN
8' - 6" 12' - 0"
8' - 0" 12' - 0" PANELS
D
PRIVATE W.C. GYPSUM DRYWALL CEILING
SOCIAL TREATMENT ELECTRICAL MECHANICAL
DIETITIAN PAT./ISOLATION
WORKER AREA

N.C. OPEN TO STRUCTURE/ NO CEILING

LINEAR BOX LIGHT 2'X4'


1
A3-1
100 LEVEL REFLECTED CEILING PLAN
1/8" = 1'-0" LINEAR BOX LIGHT 2'X2'
Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
RECESSED COVE LIGHT W/ BAFFLE plans, drawings and notes. Any authorization must be in
LOUVER writing.
RECESSED DOWNLIGHT This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
48" LINEAR PENDANT (DIRECT/INDIRECT) assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
UNDER CABINET LIGHT FIXTURE
Not published - All rights reserved.

RECESSED VANITY COVE LIGHT

SUPPLY DIFFUSER

RETURN DIFFUSER

EXHAUST DIFFUSER

SPRINKLER HEAD

WALL MOUNTED SPRINKLER HEAD 1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

100 LEVEL REFLECTED CEILING


PLAN
Sheet Name

Drawing No. A3-1


GENERAL NOTES: BUILDING ELEVATIONS
2 THE NOTES BELOW APPLY TO A4 SERIES DRAWINGS ONLY:
A4-2
1. ?
MPX ?
BX ?
PCX NUMBER DESIGNATES MATERIALS OR FINISHES
1 2 3
2. ?
GX DESIGNATES GLASS TYPE. SEE PARTIAL ELEVATIONS FOR TARGETS.

3. GLASS TYPES NOT DESIGNATED ARE TO BE ?


G1

4. TEMPERED GLASS AT DOORS & OTHER AREAS PER BUILDING CODES.

T.O. STEEL 5. LOW "E" GLASS COLOR: CLEAR, SHADING COEFFICIENT IN SPEC. SECTION
+17' - 0" 08810.

6. REFER TO A7-2 FOR FRAME TYPES & DIMENSIONS.


Department of Capital Planning & Policy
7. REFER TO SPEC. SECTION 08810 TO MATCH GLASS APPEARANCE. Bureau of Asset Management
8. HEAT TREATED WHERE REQUIRED, BOTH LITES. Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
9. EXISTING BUILDING WALL: 4" CMU ON 8" CMU BACKUP WITH 2" RIGID for their confidential use only. In consideration of the loan
INSULATION BOARD of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
10. EXISTING STOREFRONT: 2 x 4.5" THERMALLY BROKEN ALUMINUM FRAMES reproduced, copied, loaned, or otherwise disposed of
WITH KYNAR FINISH V.I.F. directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

100 LEVEL KEYNOTES LEGEND


+0' - 0" REF#
NEW HM FIXED DOOR PANEL
EXISTING UTILITIES NEW DOOR OPENING. CUT
IN EXISTING FRAME
TO REMAIN INTO EXISTING MASONRY
WALL.

1
A4-1
SOUTH ELEVATION
3/16" = 1'-0" [REF: 1/ A2-1]

Level 5
A B 1 C D 4 +9' - 8"
A4-2 NEW STOREFRONT
A4-1
TO MATCH EXISTING

SEE DETAIL 8/A9-1 4


A4-1 NEW 2" STONE SILL TO
MATCH EXISTING
G1
NEW STOREFRONT
NEW STOREFRONT
INFILL

V.I.F.
6'-8"
6' - 8"
5 5
A4-1 A4-1 4" CMU, GROUTED SOLID AND
(E) GLASS & ALUM.
DOWELED INTO ADJACENT CMU
STOREFRONT TO
REMAIN NEW CAST STONE,
2" STONE SILL TO 2" RIGGED INSULATION
MATCH EXISTING
MATCH EXISTING. CAST STONE, MATCH EXISTING 3
2"
GBDW ON FURRING A4-1

2"
CHANNEL

V.I.F.
100 LEVEL CAST STONE

1'-4"
1' - 4"
+0' - 0" PLINTH TO REMAIN
EXISTING CARD 100 LEVEL 100 LEVEL
3 Sim READER POST. +0' - 0"
+0' - 0"
A4-1 PREP AND REPAINT.

NEW CAST STONE


NEW STOREFRONT TO MATCH EXISTING
ENTRANCE DOOR IN
Holabird & Root, LLC expressly disclaims any
EXISTING FRAME
responsibility arising from any unauthorized use of these
2
A4-1
WEST ELEVATION
3/16" = 1'-0" [REF: 1/ A2-1]
3
A4-1
EXTERIOR ENTRANCE INFILL
1/2" = 1'-0" [REF: 2/ A4-1]
4
A4-1
NEW STOREFRONT SECTION
1/2" = 1'-0" [REF: 3/ A4-1]
5
A4-1
NEW STOREFRONT PLAN DETAIL
1/2" = 1'-0"
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.

EXISTING
CONCRETE
PAVING

1 09/07/2018 ISSUED FOR BID


ALIGN

No. Date Issue

EXISTING
RETAINING Project Number 15849
WALL
Drawn S. DENNY
EXISTING
ALIGN

FENCE Over all Out to Out 2. Checked K. BOYER


Ameristar Standard 6"
2" (Hinge Clearance) 3" (Latch Clearance) 2" (Hinge Clearance) Proj. Arch./Eng. K. SCHUSTER
Leaf Widths 2
3'-0"

EXISTING TM
11/2" MONTAGE PLUS Rail
BOLLARD 4" (See Cross- Section on Panel Drawing)
NEW GENERATOR. SEE Post size varies with Height
(See MONTAGE PLUS TM Post-Sizing chart)
ELECTRICAL DRAWINGS 4
Varies 1
with Gate Upright
13/4" x 14 ga.
Provident Hospital - Renal
Height
Dialysis Center
14'-0"
8'-0"

4' - 0"
7' - 4"
NEW WROUGHT 3/ "
4 x 18ga. Picket
GATE IRON FENCING. SST BASE PLATE WITH
COVER
SEE DETAIL 7/A4-1
STEEL COLUMN
Weld on Box Hinge CIP FOOTER
3'-0"

± 8'-8" 3 STEEL PLATE CROSS


2"
Nom. SUPPORT
NEW CONCRETE S.O.G. 315/16" TYP.
1'-6"

ALIGN TOP OF SLAB 36" Min.


W/EXISTING CURB Footing depth
6'-0" 430 East 51st Place

2' - 0"
NEW BOLLARDS. Chicago, Illinois 60615

2' - 6"
SEE DETAIL 8/A4-1
Double gate Arrangement Values shown are nominal and not to be used
NOTES:
for installation purposes. See product Project Name
1.) Post size depends on fence height, weight and wind loads. specification for installation requirements.

EXISTING LANDSCAPE See MONTAGE PLUS TM post sizing chart.


2.) See Ameristar gate table for standard out to outs. Custom gate
openings available for special out to out/leaf widths.
BUILDING ELEVATIONS
3.) Additional styles of gate hardware are available on request.
This could change the Latch & Hinge Clearance. 1' - 6"

6 GENERATOR ENCLOSURE 7 WROUGHT IRON GATE 8 SECTION DETAIL - CONCRETE BOLLARD AT DOORS
Sheet Name

A4-1 1/4" = 1'-0" A4-1 1/2" = 1'-0" ? A4-1 3/4" = 1'-0" ?


Drawing No. A4-1
1 2 3
2
A4-2

Department of Capital Planning & Policy


Bureau of Asset Management
T.O. STEEL
+17' - 0" Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
024119.15 return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

100 LEVEL
+0' - 0"

1
A4-2
NORTH SOUTH SECTION
3/16" = 1'-0" [REF: 1/ A2-1]
1
A4-2

A B C D

T.O. STEEL
+17' - 0"

100 LEVEL
+0' - 0" Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
2
A4-2
EAST WEST SECTION
3/16" = 1'-0" [REF: 1/ A2-1]
Drawings are not to be scaled.

Not published - All rights reserved.

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


KEYNOTES LEGEND Dialysis Center
REF#
024119.15 NEW DUCT WORK OPENINGS IN CMU BULKHEAD. SEE
MECHANICAL DRAWINGS. USE EXISTING OPENINGS WHERE
POSSIBLE. PROVIDE NEW LINTELS WHERE NECESSARY.

430 East 51st Place


Chicago, Illinois 60615

Project Name

BUILDING SECTIONS

Sheet Name

Drawing No. A4-2


SEE PLAN

4' - 8" CLEAR MIN.

4' - 6" MIN. SENSOR ABV GRAB BAR


(PLUMBING CONTR TO
EXPOSED FLUSH VALVE W/ 3' - 0" (36")
1' - 0" 3' - 6" (42") COORDINATE)

1' - 6"
SENSOR (SEE PLUMBING 102800.03 1' - 0"
DWG.) IF NO SENSOR HANDLE 102800.03
102800.04

1' - 6" (18")

5' - 0" CLEAR MIN.


ON OPEN W.C. SIDE. min
3' - 4" EXPOSED FLUSH
224000.02
VALVE (SEE PLUMB. 1' - 8" 8"

3' - 6" MIN.


DWGS.)
224000.02
224000.02

2' - 11 1/2" T/

2' - 11 1/2" T/
224000.01 224000.02 102800.04

2' - 10 3/4"

2' - 10 3/4"
3' - 4"

3' - 2"

2' - 3 1/2"

2' - 7"

2' - 4"
1' - 5"

1' - 5"
1' - 3"

Department of Capital Planning & Policy


TOILET - TYPICAL & ACCESSIBLE TOILET - ACCESSIBLE TOILET - ACCESSIBLE TOILET - TYPICAL TOILET - ACCESSIBLE Bureau of Asset Management
A B C D E
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
2" 2" 2"
for their confidential use only. In consideration of the loan
102800.06 102800.06 of this drawing, the borrower promises and agrees to
1' - 0"
102800.08 102800.08 return it upon request and agrees that it shall not be
102800.08
102800.09
reproduced, copied, loaned, or otherwise disposed of
102800.09 102800.09 directly or indirectly, nor used for any purpose other than
102800.10 102800.10 for which it is furnished, in whole or part.
TO REFLECTIVE SURFACE

TO REFLECTIVE SURFACE

224000.03 224000.03 224000.03

TO HANDLE

TO HANDLE

TO WORK SURFACE
4' - 0" MAX

4' - 0" MAX


3' - 10"

3' - 10"

3' - 10"

2' - 10" MAX


3' - 4"

3' - 4"

2' - 7" MAX


2' - 10"

2' - 10"

1' - 3" MIN. IF ADJACENT

CLEAR
TO WALL, U.N.O.

LAVATORY, MIRROR, & ACCESSORIES LAVATORY, MIRROR, & ACCESSORIES LAVATORY, MIRROR, & ACCESSORIES BABY CHANGING STATION BABY CHANGING STATION
F G ADJACENT TO WALL - FRONT VIEW
H ADJACENT TO WALL - SIDE VIEW
I J

1
A6-1
TOILET ROOM ELEVATIONS, PLANS, ACCESSORIES AND MISC.
N.T.S.

AUDIO/VISUAL ALARM CENTERED


ABOVE FIRE ALARM PULL
RECESSED FIRE EXTINGUISHER CABINET W/
SIGNAGE, U.N.O 1/2" PROJECTING FRAME & WHITE FINISH.
(VERTICAL RED DIE-CUT LETTERING FOR "FIRE
FIRE ALARM PULL EXTINGUISHER")

COORDINATE DOOR SWING @ CABINET


COAT HOOK, DOOR FOR DOOR TO SWING AGAINST
MOUNTED
ADJACENT WALL
DOOR IS 4" AWAY FROM ADJACENT
WALL FOR 90-DEGREE PER ACC 6" TO AT 34" ACCESSIBLE TOP - 46"
TO CL OF ELEC. OUTLET
C
L 8" 8" TO TYP.
1' - 1"
AT 36" NON-ACCESSIBLE TOP - 46"
DOOR OPENING IS 18" (MIN) FOR TO CL OF ELEC. OUTLET
OF ALARM (ACC)

FRONT APPROACH PER ACC


4"

TO HIGHEST OPERABLE HEIGHT


1' - 6"

2' - 4"

1' - 0"
(ACC)

10"
8"
3' - 10" (ACC) MAX.

4' - 7 1/4"
5' - 0"
4' - 0" (ADA)

3' - 10" (46")


6' - 8" TO

4' - 10" TO

4' - 0"
3' - 10"

2' - 10" (34")

3' - 0"
2' - 3 1/4"

1' - 6"
1' - 0"
NOTE FOR SWITCHES: ELECTRIC LIGHT SWITCH CABINET W/ FIRE EXTINGUISHER
ALL SWITCHES MUST BE DESIGNED FOR THERMOSTAT ELECTRICAL OUTLET (MOUNT
WHEELCHAIR FRONT REACH (2010 ADA). WALL PHONE TO ALIGN VERTICAL U.N.O. ON ELEC. DWG.)
DOOR OPENING IS 12" (MIN) FOR FRONT W/ TOP OF LIGHT SWITCH
APPROACH IF CLOSER & LATCH PER ACC 34" ACCESSIBLE TOP W/ 4" BACKSPLASH Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
2
A6-1
CLEARANCE PLAN AT DOORWAYS, TYP.
N.T.S.
3
A6-1
ELEVATION - ACCESSIBLE MOUNTING HEIGHTS
N.T.S.
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
1' - 10" DOOR FRAME
NURSE TERMINAL Not published - All rights reserved.
LIGHT SWITCH 6" TYP.
DOOR FRAME LENGTH
THERMOSTAT CH-4
LIGHT SWITCH SEE ELEVATIONS
EQ EQ WALL PHONE CH-1
HAND SANITIZER HAND SANITIZER

48" ACCESSIBLE
84"

60"
48" MAX

50 1/2"
47 3/4"

47 3/4"

54"
48"
48"

CONFIRM W/
46"

46"

46"

46"

46"

ARCHITECT
15" MIN

8" 8" 9"

6" UNO 6 1/4" 6" UNO


GENERAL REACH RANGE FOR APRON RACK CLOCK DATA & ELEC IN ALCOVE ACCESSORIES ACCESSORIES NURSE CALL DEVICE THERMOSTAT COAT HOOKS (CH-X) COAT HOOK, ACCESSIBLE (CH-X) DIAGNOSTIC INSTRUMENT EQUIPMENT RAIL WALL MOUNTED
MIN AND MAX HEIGHTS, U.N.O. ADJACENT TO DOOR ADJACENT TO DOOR (TOILET ROOMS) PANEL (DISE-01) COMPUTER MONITOR, NIC 1 09/07/2018 ISSUED FOR BID
BRACKET
No. Date Issue

Project Number 15849


Drawn S. DENNY
TO HIGHEST OPERABLE HEIGHT

TO HIGHEST OPERABLE HEIGHT

Checked K. BOYER
22"

Proj. Arch./Eng. K. SCHUSTER


69 1/2"

57 3/4"

45 1/2"
48"

48"
44"

44"

44"

44"

44"
34"

34"

34"

34"
32"
30"

Provident Hospital - Renal


14"
Dialysis Center
AED DEVICE GLOVE BOX HOLDER GLOVE BOX HOLDER, ABOVE HAND SANITIZER, WALL MARKER/TACKABLE SURFACE, MOP RACK SPECIMEN SHARPS CONTAINER SHARPS CONTAINER, ABOVE TELEVISION PAPER TOWEL DISPENSER, ABOVE CHAIR RAIL
KEYNOTES LEGEND
COUNTER MOUNTED ABOVE COUNTER PASS THROUGH COUNTER COUNTER & IN TOILET ROOMS REF#
102800.03 GRAB BAR (42") AND VERTICAL GRAB BAR (18")
102800.04 GRAB BAR (36")

4
A6-1
TYPICAL EQUIPMENT MOUNTING HEIGHTS
N.T.S.
102800.06
102800.08
MIRROR - ABOVE COUNTERTOP (SURFACE MOUNTED)
PAPER TOWEL DISPENSER
102800.09 SOAP DISPENSER
102800.10 BABY CHANGING TABLE
224000.01 WATER CLOSET
430 East 51st Place
224000.02 WATER CLOSET - ACCESSIBLE Chicago, Illinois 60615
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ PIPE
COVER
Project Name

TYPICAL PLANS, ELEVATIONS, &


DETAILS
Sheet Name

Drawing No. A6-1


224000.03
102800.13

PAT. TOILET
114 102800.06
4
102800.09
102800.09 102800.03 102800.06
7 A6-2 5 102800.09

5' - 11"
102800.03
102800.04 102800.04
224000.02 6 102800.09
102800.13 224000.03
B NURSE CALL
102800.03
224000.03
102800.03
Department of Capital Planning & Policy
102800.04 224000.03
BUTTON
102800.03
Bureau of Asset Management

1' - 6"
224000.02 224000.02 224000.02
TILE COVE Notice: This drawing has not been published and is the
TILE COVE TILE COVE sole property of Cook County. It is loaned to the borrower
BASE, TYP. BASE, TYP.
BASE, TYP. for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
PBT1 PWT1 PBT1 PWT1 PBT1 reproduced, copied, loaned, or otherwise disposed of
7' - 2" directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

1
A6-2
114_PATIENT TOILET
1/2" = 1'-0"
4
A6-2
PATIENT TOILET - WEST
3/8" = 1'-0" [REF: 1/ A6-2]
5
A6-2
PATIENT TOILET - NORTH
3/8" = 1'-0" [REF: 1/ A6-2]
6
A6-2
PATIENT TOILET - EAST
3/8" = 1'-0" [REF: 1/ A6-2]
7
A6-2
PATIENT TOILET - SOUTH
3/8" = 1'-0" [REF: 1/ A6-2]
8
A6-2
WATER CLOSET - NORTH
3/8" = 1'-0" [REF: 2/ A6-2]

5' - 3 1/2"

NURSE CALL
102800.08
BUTTON
W.C. 102800.09
117A 102800.03
224000.03
11 102800.10
224000.03
10 A6-2 8 224000.02
TILE COVE
9 TILE COVE TILE COVE
9' - 2 1/2"

BASE, TYP.
BASE, TYP. BASE, TYP.
224000.03

102800.09
PBT1 PBT1
224000.02

9
A6-2
WATER CLOSET - EAST
3/8" = 1'-0" [REF: 2/ A6-2]
10 WATER CLOSET - SOUTH
A6-2 3/8" = 1'-0" [REF: 2/ A6-2]
11 WATER CLOSET - WEST
A6-2 3/8" = 1'-0" [REF: 2/ A6-2]
12 STAFF TOILET - NORTH
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
13 STAFF TOILET - EAST
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
1' - 6"

102800.04

102800.03

102800.03
102800.06
NURSE CALL 102800.10
102800.09
BUTTON
102800.08 102800.04
224000.03 102800.03 102800.09
102800.04

2
A6-2
117A_WATER CLOSET
1/2" = 1'-0" PWT1
224000.02

TILE COVE
224000.02 Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
BASE, TYP. writing.
PBT1
This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
102800.10 Drawings are not to be scaled.
224000.02
102800.03
REMOVE 6"X6" TILE
ON EXISTING WALL 14 STAFF TOILET - SOUTH
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
15 STAFF TOILET - WEST
A6-2 3/8" = 1'-0" [REF: 3/ A6-2]
Not published - All rights reserved.

A
1' - 6"

15
5' - 6"

14 A6-2 12
102800.04

102800.09 13 STAFF
TOILET
113B

224000.03
1 09/07/2018 ISSUED FOR BID
102800.08
No. Date Issue

8' - 9 3/4" Project Number 15849


Drawn S. DENNY

3
A6-2
113B_STAFF TOILET
1/2" = 1'-0"
Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

KEYNOTES LEGEND
REF#
102800.03 GRAB BAR (42") AND VERTICAL GRAB BAR (18")
102800.04 GRAB BAR (36")
102800.06 MIRROR - ABOVE COUNTERTOP (SURFACE MOUNTED)
102800.08 PAPER TOWEL DISPENSER
430 East 51st Place
102800.09 SOAP DISPENSER Chicago, Illinois 60615
102800.10 BABY CHANGING TABLE
102800.13 SEMI-RECESSED PAPER TOWEL DISPENSER & WASTE
RECEPTACLE; 12-GAL WASTE CONTAINER. Project Name
224000.02 WATER CLOSET - ACCESSIBLE
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ PIPE TOILET ROOMS
COVER

Sheet Name

Drawing No. A6-2


ALL 4-7/8" PARTITIONS ARE PARTITION LEGEND
DIMENSIONED 5" ON
PLANS FIRE-RATED PARTITION
4 7/8" 6 1/8" 7 1/4" 4 1/4" PARTITION TYPE PARTITION TYPE
5/8" 3 5/8" 5/8" 5/8" 3 5/8" 5/8" 5/8" 6" 5/8" 3 5/8" 5/8" 3 5/8" METAL STUD (U.N.O.) D1.1 D1.1
3 5/8" METAL STUD (U.N.O.) 3 5/8" METAL STUD (U.N.O.) 3 5/8" METAL STUD (U.N.O.) S S
EXTENT OF GPDW
EXTENT OF GPDW
5/8" 5/8" 5/8" GPDW (U.N.O.)
5/8" GPDW (U.N.O.) 5/8" GPDW (U.N.O.)
5/8" TYPE "X" GPDW (USG
5/8" TYPE "X" GPDW (USG 2 LAYERS 5/8" GPDW (U.N.O.) 5/8" TYPE "X" GPDW (USG TYP. FIRE RATED PARTITION TYP. NON-RATED PARTITION
FIRECODE 'C') @ RATED
FIRECODE 'C') @ RATED 5/8" TYPE "X" GPDW (USG FIRECODE 'C') @ RATED
WALLS
WALLS FIRECODE 'C') @ RATED WALLS WALLS
1 1/2" SOUND EXTENT OF GPDW
1 1/2" SOUND 1 1/2" SOUND 1 1/2" SOUND
ATTENUATION ATTENUATION ATTENUATION
ATTENUATION X = HEIGHT OF STUDS/CMU & GPDW
BLANKET AT BLANKET AT BLANKET AT
BLANKET AT s
s s s 1 STUDS/CMU TO UNDERSIDE OF SLAB, GPDW TO SLAB

2 STUDS/CMU TO SLAB, GPDW TO 4" ABOVE CEILING


Department of Capital Planning & Policy
Bureau of Asset Management
3 STUDS/CMU TO CEILING, GPDW TO CEILING Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
D1.X 3 5/8" METAL STUD D2.X 3 5/8" METAL STUD D5.X 6" METAL STUD D40.X 3 5/8" METAL STUDS 4 LOW WALL, SEE A2-1 THRU A2-2 FOR HEIGHT for their confidential use only. In consideration of the loan
(40 STC) AT s (55 STC) AT s (40 STC) AT s (40 STC) AT s of this drawing, the borrower promises and agrees to
(UL DES U419 @ 1-HR RATED WALLS) (UL DES U419 @ 2-HR RATED WALLS) (UL DES U419 @ 1-HR RATED WALLS) (UL DES U419 @ 1-HR RATED WALLS) CLASSIFICATION FOR GPDW PARTITIONS return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
D1 THRU D39 STANDARD PARTITION TYPES directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.
DRYWALL PARTITIONS D40 THRU D59 CHASE WALLS

D60 THRU D79 SPECIAL CONDITIONS


7 1/8" 8 5/8" SEE PLANS
F1 THRU F9 FURRING WALL
5 5/8" 5 5/8" 1 1/2" 1 1/2" 5 5/8" 1 1/2" 5 5/8" 2 1/2" METAL STUD W/ 2 7 5/8"
1/2" STUD CROSS S1 THRU S25 SHAFT WALLS
BRACING @ 24" O.C.
GENERAL NOTES: PARTITION TYPES
5/8" GPDW
CMU (16" LONG X 8" HIGH 7/8" METAL FURRING CHANNEL 7/8" METAL FURRING CHANNEL CMU (16" LONG X 8" HIGH 1. SEE PARTITION TYPES FOR STUD DEPTHS. SEE PARTITION SCHEDULE FOR STUD
MODULAR BLOCK) 2-HR RATED WITH SHIM AS REQUIRED WITH SHIM AS REQUIRED CMU (16" LONG X 8" MODULAR BLOCK) 2-HR RATED GAUGE & STUD SPACING.
HIGH MODULAR BLOCK)
5/8" GPDW 5/8" GPDW 2-HR RATED 2. SEE PLANS FOR PARTITION TYPES. ALL NEW PARTITIONS ON PLAN TO BE TYPE D1.1
S
UNLESS NOTED OTHERWISE.
CMU (16" LONG X 8" HIGH CMU (16" LONG X 8" HIGH
MODULAR BLOCK) 2-HR RATED MODULAR BLOCK) 2-HR RATED
3. ALL CERAMIC TILE ON THE WALL IS THIN SET (APPROXIMATE 3/8" THICK). THE
DIMENSION OF THE WALL PARTITION THICKNESS ON THE PLANS DO NOT INCLUDE
THE 3/8" THICKNESS.

4. PARTITIONS ENCLOSING SPACES WITHOUT CEILINGS ARE TO EXTEND TO UNDERSIDE


OF DECK ABOVE.
C11.X 6" CMU C12.X 6" CMU C13.X 6" CMU C14.X 6" CMU C21.X 8" CMU
(UL DES U906 @ 2-HR RATED WALLS) (UL DES U906 @ 2-HR RATED WALLS) (UL DES U906 @ 2-HR RATED WALLS) (UL DES U906 @ 2-HR RATED WALLS) (UL DES U @ 3-HR RATED WALLS) 5. ALL FIRE RATED PARTITION ASSEMBLIES ARE TO BE CARRIED TO THE SLABABOVE &
VOIDS FILLED AT TOP.

CMU OR CMU SUBSTRATE FOR PARTITIONS 6. ALL VOIDS THROUGH & AT THE PERIMETER OF FIRE RATED PARTITIONS ARE TO BE
FILLED WITH FIRE STOPPING PRODUCTS.

7. ALL GPDW PARTITIONS, SOFFITS, FASCIAS, ETC. ARE TO HAVE METAL DRYWALL TRIM &
1 1/2" METAL CORNER BEAD (NO PLASTIC TRIM).

8. INSTALL A CONTROL JOINT SYSTEM @ 30'-0" MAX. FOR GPDW PARTITIONS.


5/8" GPDW TO 4" ABOVE CEILING
9. ALL GPDW PARTITIONS:
A. ALL FIRE RATED PARTITIONS AND PARTITIONS WITH SOUND ATTENUATION TO BE
7/8" METAL FURRING CHANNEL
CAULKED @ PERIMETER.
WITH SHIM AS REQUIRED
B. NON-RATED METAL STUD PARTITIONS ARE TO HAVE STUDS EXTENDED TO
VAPOR RETARDER, ADHERE STRUCTURE ABOVE (U.N.O).
TO CMU @ TOP & BOTTOM C. ALL GPDW PARITIONS IN TOILETS, PANTRY AREAS, KITCHENS, & JANITOR'S
CLOSETS TO EXTEND TO THE STURCTURE ABOVE.
EXISTING WALL D. FOR TYPICAL SHAFTWALL PARTITIONS THE 1" LINER PANEL IS TO BE EXPOSED TO
THE SHAFT SIDE & OTHER GPDW TO BE EXPOSED TO THE ROOM SIDE.
E. USE WATER RESISTANT GPDW ON ALL PARTITIONS WHICH ARE PENETRATED BY
PLUMBING PIPING. Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
10. ALL CMU OR BLOCK PARTITIONS: plans, drawings and notes. Any authorization must be in
A. ALL FIRE RATED PARTITIONS AND PARTITIONS WITH SOUND ATTENUATION TO BE writing.
CAULKED @ PERIMETER.
F9.X EXISTING WALL B. FIRE RATED UNITS SHALL COMPLY W/ THE STANDARDS OF AMERICAN This drawing copy may have been reproduced at a size
INSURANCEASSOCIATION AND SHALL HAVE AN EQUILVALENT THICKNESS IN different than originally drawn. The Owner and Architect
EXCESS ON MIN. REQUIREMENTS. (COORDINATE PARTITION TYPE W/ RATING assume no responsibility for use of incorrect scale.
FURRING WALL PARTITIONS SYMBOLS ON PLANS).
C. 5" HIGH X 16" STARTER COURSE TO BE PROVIDED AT PARTITIONS W/ 7'-0" HIGH
Drawings are not to be scaled.

DOOR FRAMES Not published - All rights reserved.


FIRE RATED GPDW PARTITION, SEE FIRE -RATED GPDW PARTITION ,
PLANS FOR PARTITION TYPES SEE PLANS FOR PARTITION TYPES
D. CMU PARTITIONS NOT EXTENDED TO SLAB ABOVE TO BE LATERALLY BRACED W.
FIRE-RATED GPDW PARTITION, METAL STUD KICKERS AT TOP OF THE PARTITION, U.N.O. COORDINATE
SEE PLANS FOR PARTITION TYPES 1/4" FIRE BARRIER WRAP STRIP W/ HVAC & OTHER TRADES.
PIPE OR CONDUIT TO BE CENTERED FIRE-RATED GPDW PARTITION, SEE
WITHIN THE FIRESTOP SYSTEM AND RIGIDLY PIPE COVERING PLANS FOR PARTITION TYPES
CABLE OR CABLE BUNDLE 1"O.D. MAX.
SUPPORTED ON BOTH SIDES RIGIDLY SUPPORTED ON BOTH SIDES 1/2" 11. PROVIDE FIBERGLASS FACED GPDW AT ALL WET WALLS.
ONE METALLIC PIPE OR TUBING TO MINERAL WOOL BATT PACKING, 1" MIN.
BE CENTERED WITHIN THE FIRESTOP
SYSTEM AND RIGIDLY SUPPORTED ON BOTH STEEL SLEEVE
SIDES FIRE BARRIER CAULK, 1" MIN. STEEL STUD SCHEDULE - INTERIOR PARTITIONS & USES
6" MAX.

CABLE BUNDLE ALLOW. MAXIMUM STUD HEIGHT


CAULK FILL MATERIAL TO STUD TYPE & DATA GPDW LAYERS
COMPLETELY FILL ANNULAR APACE BETWEEN CAULK FILL MATERIAL TO COMPLETELY DEFLECT. 2 1/2" 3 5/8" 4" 6"
FILL ANNULAR SPACE BETWEEN PIPE 1/4" CONT. BEAD OF FIRE CAULK 1/4" CONT. BEAD OF FIRE CAULK
PIPE AND GPDW, 1/4" CONT. BEAD OF FIRE CAULK
AND GPDW, 1/4" CONT. BEAD OF FIRE CAULK RIBBED [DIETRCH DATA] (1) 5/8" EACH SIDE L/240 11'-10" 15'-4" 16'-9" 21'-10"
GAUGE: 25 (0.0155")
(1) 5/8" EACH SIDE L/360 10'-4" 13'-1" 14'-7" 19'-1"
SINGLE PIPE/CONDUIT THROUGH SINGLE INSULATED PIPE THROUGH SINGLE INSULATED PIPE THROUGH CABLE BUNDLE THROUGH STUD SPACING 16" O.C.
AIR PRESSURE: 5 PSF (2) 5/8" EACH SIDE L/240 15'-1" 17'-0" 15'-9" 23'-8"
GYPSUM WALLBOARD ASSEMBLY GYPSUM WALLBOARD ASSEMBLY GYPSUM WALLBOARD ASSEMBLY GYPSUM WALLBOARD ASSEMBLY
(UL SYSTEM #W-L-1001) (UL SYSTEM #W-L-3001) (UL SYSTEM #W-L-5001) (UL SYSTEM #W-L-3032) (2) 5/8" EACH SIDE L/360 13'-2" 14'-0" 16'-7" 20'-8"
1, 2, 3 & 4 HR RATING FIRE-RATED FLOOR OR WALL 1 & 2 HR RATING 1 & 2 HR RATING 1 & 2 HR RATING
1 09/07/2018 ISSUED FOR BID
ASSEMBLY, 3 1/4" MIN. CONCRETE NON-RIBBED [USG DATA] (1) 5/8" EACH SIDE L/240 12'-6" 16'-0" 17'-3" 20'-0" No. Date Issue
OR UL CLASSIFIED CMU FIRE-RATED FLOOR OR WALL GAUGE: (0.0188")
ASSEMBLY, 2 1/2" MIN. CONCRETE CABLE BUNDLE, RIGIDLY STEEL DUCT, RIGIDLY
STUD SPACING: 16" O.C. (1) 5/8" EACH SIDE L/360 10'-9" 14'-0" 15'-0" 20'-0"
OR UL CLASSIFIED CMU SUPPORTED ON BOTH SIDES SUPPORTED ON BOTH SIDES
PIPE OR CONDUIT TO BE CENTERED AIR PRESSURE: 5 PSF (2) 5/8" EACH SIDE L/240 13'-6" 16'-9" 17'-3" 20'-0"
WITHIN THE FIRESTOP SYSTEM AND PIPE COVERING FIRE-RATED FLOOR OR WALL FIRE-RATED FLOOR OR WALL Project Number 15849
6 1/4" MAX.
RIGIDLY SUPPORTED ON BOTH SIDES ASSEMBLY, 4 1/2" MIN. CONCRETE ASSEMBLY, 4 1/2" MIN. CONCRETE
ONE METALLIC PIPE OR TUBING OR UL CLASSIFIED CMU OR UL CLASSIFIED CMU
(2) 5/8" EACH SIDE L/360 11'-9" 14'-9" 15'-9" 20'-0"
TO BE CENTERED WITHIN THE Drawn S. DENNY
CHASE WALL [USG DATA] (1) 5/8" EACH SIDE L/240 13'-3" 17'-6" 22'-9"
1'-6" MAX.

FIRESTOP SYSTEM AND RIGIDLY


6" MAX.

SUPPORTED ON BOTH SIDES GAUGE: 25 (0.0188") Checked K. BOYER


(1) 5/8" EACH SIDE L/360 11'-6" 15'-6" 19'-9"
STUD SPACING: 16" O.C.
Proj. Arch./Eng. K. SCHUSTER
AIR PRESSURE: 5 PSF (2) 5/8" EACH SIDE L/240 14'-6" 19'-0" 23'-6"
FIRE BARRIER CAULK, 1" MIN. FIRE BARRIER CAULK, 1" MIN.
PUTTY, 3 1/4" MIN. THICKNESS OF MINERAL WOOL BATT PACKING, 1" MIN. MINERAL WOOL BATT PACKING, (2) 5/8" EACH SIDE L/360 12'-9" 16'-6" 21'-3"
FILL MATERIAL FLUSH WITH BOTH FIRE BARRIER CAULK, 1" MIN. 1" MIN.
FACES OF WALL/FLOOR MINERAL WOOL BATT PACKING, 1" MIN. 1/2" C-H 4" C-H 6" C-H DBL. 6"
STUD STUD STUD E STUD
SINGLE INSULATED PIPE THROUGH SINGLE INSULATED PIPE THROUGH CABLE BUNDLE THROUGH STEEL DUCT THROUGH SHAFT WALL [USG DATA] 1" SHAFT + (2) 5/8" L/240 10'-5" 13'-10" 23'-11" 26'-3"
Provident Hospital - Renal
CONCRETE OR CMU WALL/FLOOR CONCRETE OR CMU WALL/FLOOR CONCRETE WALL/FLOOR CONCRETE OR CMU WALL/FLOOR
GAUGE: 25 (0.0188") OTHER SIDE Dialysis Center
(UL SYSTEM #C-AJ-1041) (UL SYSTEM #C-AJ-5001) (UL SYSTEM #C-AJ-3021) (UL SYSTEM #C-AJ-7003)
STUD SPACING: 16" O.C.
1 & 2 HR RATING 1 1/2, 2 & 3 HR RATING 2 HR RATING 3 HR RATING
3-5/8" RUNNER METAL AIR PRESSURE: 5 PSF 1" SHAFT + (2) 5/8" L/240 9'-3" 12'-6" 19'-2" 23'-0"
ROOF CONSTRUCTION 3-5/8" METAL STUD, TRACK OTHER SIDE
ROOF CONSTRUCTION U.N.O.
ROOF CONSTRUCTION ROOF CONSTRUCTION EXISTING STRUCTURAL MEMBER EXISTING STRUCTURAL MEMBER CEILING SUSPENSION
UL RATED 4 PCF DENSITY MINERAL UL RATED 4 PCF DENSITY MINERAL SPRAY-APPLIED FIRE RESISTIVE MATERIAL 14 GA. MISC. STEEL PLATE; MIN 1 1/2" TIE-ROD TO UNDERSIDE THE NOTES BELOW APPLY TO PARTITION SCHEDULE ABOVE.
OVERLAP OF SUPPORT GRID, TYP.
WOOL BATT INSULATION PACKED INTO WOOL BATT INSULATION PACKED INTO AFTER INSTALLATION OF METAL STUD 1. ALL GPDW PARTITIONS ARE BASED ON "DIETRCH" OR "USG" DATA. OTHER
FLUTE VOID FLUTE VOID RUNNER TRACK. FILL THE ENTIRE FLUE VOID SPRAY-APPLIED FIRE RESISTIVE MATERIAL
AFTER INSTALLATION OF METAL STUD RUNNER
MANUFACTURERS TO MEET OR EXCEED PARTITION PERFORMANCE LISTED ABOVE.
UL RATED CAVITY MATERIAL; MIN 1/2". AT TOP OF STEEL BEAM,
METAL STUD RUNNER TRACK; SECURED TO TRACK. FILL THE ENTIRE FLUE VOID AT TOP OF 2. FOR HEIGHTS OVER MAX. HEIGHTS LISTED USE KICKERS TO STRUCTURE ABOVE.
THE BOTTOM OF STEEL FLANGE THRU STEEL BEAM, (COORDINATE W/ HVAC & OTHER TRADES).
25 GA. RESTRAINING ANGLES 25 GA. RESTRAINING ANGLES
MIN.

SPRAY FIRE RESISTIVE MATERIAL METAL STUD RUNNER TRACK; SECURED 3. USE L/360 ALLOWABLE DEFLECTION FOR "TILED" WALLS.
6"

MIN. 2 1/2" x 2 1/2" MIN. 2 1/2" x 2 1/2"


TO THE BOTTOM OF STEEL FLANGE
5/8" TYPE "X" GPDW 5/8" TYPE "X" GPDW UL RATED 4 PCF DENSITY MINERAL WOOL 430 East 51st Place
BATT INSULATION STRIPS TO FILL GAP AT UL RATED VOID SEALANT TO
BOTTOM OF BEAM & TOP OF GPDW COMPLETELY FILL GAP; 1/4" MAX JOINT
Chicago, Illinois 60615
ACOUSTICAL CEILING SOUND ATTENUATION
METAL STUD RUNNER TRACK METAL STUD RUNNER TRACK SPRAY FILL MATERIAL COMPLETELY OVER SPACE; OVERLAP 1/2" ON GPDW.
GRID, SEE ID SHEETS BLANKET
SEE D1.X & D2.X FOR RATED PARTITION NOTES SEE D1.X & D2.X FOR RATED MINERAL WOOL & OVERLAP GPDW BY 1/2"
SEE D1.X & D2.X FOR RATED PARTITION NOTES Project Name
PARTITION NOTES SEE D1.X & D2.X FOR RATED PARTITION NOTES END OF GRID BRACKET 5/8" GPDW (U.N.O.)
5/8" TYPE "X" GPDW (USG
RATED TOP OF GPDW RATED TOP OF GPDW RATED TOP OF GPDW WALL RATED TOP OF GPDW WALL PARTITION FIRECODE 'C') @ RATED PARTITION TYPES & DETAILS
WALLS
WALL PARTITION WALL PARTITION PARTITION OF STEEL BEAM OFFSET FROM STEEL BEAM
(UL SYSTEM #HW-D-001 & DW-D-002) (UL SYSTEM #HW-D-001 & DW-D-002) (UL SYSTEM #HW-D-0259) (UL SYSTEM #HW-S-0096)
1 & 2 HR RATING 1 & 2 HR RATING 1 & 2 HR RATING 1 & 2 HR RATING
Sheet Name
2 FIRE PENETRATIONS & NOTES 1 SECTION DETAIL AT TOP OF WALL - DX.2
A7-1 N.T.S. A7-1 N.T.S. Drawing No. A7-1
DOOR SCHEDULE GENERAL NOTES: DOORS SCHEDULE GENERAL NOTES: DOORS & FRAMES
OPENING SIZE DOOR FRAME 1. THE BELOW ITEMS ARE COMMENTS ABOUT DOOR SCHEDULE: 1. ALL DOOR CLOSERS & OPENING FORCE SETTINGS FOR
FIRE RATING ACCESSIBLE DOORS TO COMPLY W/ ACCESSIBILITY STANDARDS.
DOOR NO. WIDTH HGT. TYPE. MATL. (MINS) U.C. TYPE MATL. JAMB HEAD SILL HDW. NO. REMARKS 2. DOOR#: INDICATES THE DOOR NUMBER ON FLOOR PLANS. FIRE RATED DOORS SHALL HAVE THE MIN. OPENING FORCE
100 LEVEL ALLOWABLE BY LOCAL CODE AUTHORITIES.
3. OPENING SIZE (WXH): INDICATES THE OPENING WIDTH (W)
BETWEEN JAMBS & OPENING HEIGHT (H) BETWEEN SUBSTRATE 2. ALL DOORS & HARDWARE TO COMPLY WITH ACCESSIBILITY
100A.A 4' - 0" 8' - 0" E1 ALUM EX ALUM AC1.7 REPLACE CENTER PIVOT ENTRY DOOR. AUTOMATIC OPERATOR, PEDESTAL MOUNT PUSH BUTTON, CARD @ FLOOR & BOTTOM OF THE HEAD. STANDARDS. SEE PLANS FOR DOOR SYMBOL. ALL DOORS WITH 3
READER, EX. OPENING, VERIFY EXISTING OPENING SIZE. SIDED FRAME (U.N.O. ON DOOR SCHEDULE OR ELEVATIONS).
100A.B 4' - 0" 8' - 0" E1 ALUM EX ALUM AC1.6 REPLACE CENTER PIVOT ENTRY DOOR. AUTOMATIC OPERATOR, EX. OPENING, VERIFY EXISTING OPENING SIZE. 4. ALL DOORS ARE 1 3/4" THICK (U.N.O.)
100B 3' - 4" 7' - 0" A1 WD F3 HM HJ-D1 HJ-D1 1.3 3. ALL DOORS USED IN CONJUNCTION W/EXITS SHALL BE SO
5. DOOR TYPE: INDICATES DOOR TYPE, SEE DOOR TYPES ON A7-2. ARRANGED AS TO BE READILY OPENED WITHOUT THE USE OF A
100C 3' - 4" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 1.3
KEY (U.N.O) FROM THE SIDE FROM WHICH EGRESS IS MADE.
100D 6' - 0" 7' - 0" EX HM EX HM - EXISTING DOOR AND FRAME TO REMAIN. ADD CARD READER. 6. ALL DOORS ARE FLUSH CONSTRUCTION (U.N.O.).
102 3' - 0" 8' - 0" D1 ALUM F1 ALUM HJ-D1 HJ-D1 5.1 4. ALL FIRE-RATED DOORS SHALL HAVE FIRE-RATED CLOSERS; ALL
103 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 4.0 7. DOOR MATL: INDICATES MATERIAL (MATL) OF DOOR. SEE SPEC. DOOR FRAMES & HARDWARE TO BE FIRE LISTED TO MATCH FIRE
Department of Capital Planning & Policy
104 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 4.0
FOR SPECIFIC FINISH. DOOR RATINGS. Bureau of Asset Management
105 3' - 0" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 4.0 WD = WOOD PW = PAINTED WOOD 5. ALL EXIT DOORS SERVING MORE THAN 200 PERSONS SHALL HAVE
Notice: This drawing has not been published and is the
106 3' - 4" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 5.0 HM = HOLLOW METAL HC = HOLLOW CORE WOOD sole property of Cook County. It is loaned to the borrower
PANIC HARDWARE.
107 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN. REFINISH EXISTING DOOR ALUM = ALUMINUM GL = GLASS (W/OUT METAL STILES) for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
108 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN. REFINISH EXISTING DOOR 6. PROVIDE KNURLED LEVER HARDWARE HANDLES AT ELECTRICAL,
8. DOOR LABEL: INDICATES FIRE RATED LABEL (LBL) OF DOOR & return it upon request and agrees that it shall not be
109 3' - 0" 7' - 0" A1 WD F1 HM HJ-C11 HJ-C11 4.0 MECHANICAL & HAZARDOUS AREAS PER ACCESSIBILITY
FRAME. reproduced, copied, loaned, or otherwise disposed of
STANDARDS.
110 3' - 0" 7' - 0" A1 WD F1 HM HJ-C11 HJ-C11 4.0 directly or indirectly, nor used for any purpose other than
111 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 AC1.5 (-) = NO LABEL for which it is furnished, in whole or part.
7. COORDINATE ALL SECURITY ACCESS DEVICES W/OWNER.
112 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 3.0 A LABEL 120 = 120 MINUTES = 2 HR
113 3' - 0" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 2.2 B LABEL 90 = 90 MINUTES = 1 1/2 HR 8. ALL HM & WOOD DOORS HAVE 6 1/2" WIDE DOOR STILES (U.N.O.)
C LABEL 45 = 45 MINUTES = 3/4 HR W/ 7" MIN. HIGH TOP RAIL.
113A 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 6.0
113B 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 6.0 9. U.C.: COORDINATE DOOR SIZE W/ SPECIFIC UNDERCUT (UC) & 9. ALL ALUM DOORS HAVE 5" WIDE STILES (U.N.O.) & G.C. TO COORD.
114 3' - 6" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 6.0 FLOOR MATERIAL THICKNESS ABOVE FLOOR SUBSTRATE. W/ SPECIFIC HARDWARE.
117 3' - 6" 8' - 0" D1 ALUM F1 ALUM (-) = 5/8" TYPICAL (U.N.O.).
117A 3' - 6" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 6.0 10. BOTTOM STILE OF ALUM OR HM DOORS TO BE FLUSH WITH NO
10. FRAME TYPE: INDICATES FRAME TYPE, SEE FRAME TYPES ON EXPOSED SURFACE PLATES OR FASTENERS EXCEPT FOR
118 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 2.1 A7-2. SURFACE APPLIED KICKPLATES THAT ARE CALLED OUT IN
119 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 2.1 HARDWARE SCHEDULE.
120 3' - 6" 7' - 0" C1 WD F1 HM HJ-D1 HJ-D1 2.1 11. FRAME MATL: INDICATES MATERIAL (MATL) OF FRAME. SEE NOTE
121 3' - 0" 7' - 0" B1 WD F1 HM HJ-D1 HJ-D1 2.1 ABOVE FOR ABBREVIATIONS. 11. NO "THRU BOLTING" ON DOORS OR FRAMES (PROVIDE ADEQUATE
122 3' - 0" 7' - 0" A1 WD F1 HM HJ-D1 HJ-D1 2.1 OR 3.0 BLOCKING IN DOOR FOR CLOSER ATTACHMENT). NO EXPOSED
12. JAMB, HEAD & SILL: INDICATES HEAD, JAMB & SILL DETAILS FASTENERS OR SCREWS FOR HARDWARE AT DOORS, EXCEPT
123 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN SHOWN IN ARCHITECTURAL DRAWINGS. NUMBER IS USED FROM FOR F.H.W.S. FOR KICK PLATES.
124 3' - 0" 7' - 0" EX WD EX HM EXISTING TO REMAIN TYP. DOOR DETAIL DRAWING SHEET A7-4 (U.N.O.); REFER TO ID
125A 3' - 6" 7' - 0" C1 HM F1 HM HJ-D40 HJ-D40 2.2 SERIES FOR INTERIOR SILLS. 12. RATED DOOR LOUVER TO HAVE FUSIBLE LINK; 24"X24" MAX.,
125B 6' - 0" 7' - 0" A2 HM F1 HM 1.0 COORD. SIZE W/ MECHANICAL DRAWINGS
13. HDW#: INDICATES HARDWARE (HDW) NUMBER THAT IS DEFINED
126 7' - 0" 7' - 0" EXISTING TO REMAIN. GARBAGE ENCLOSURE. IN FINISH HARDWARE SPEC. SECTION. 13. EXTERIOR DOOR FRAMES ARE GALVANIZED. EXTERIOR DOORS
127 7' - 0" 7' - 0" EXISTING TO REMAIN. GARBAGE ENCLOSURE. ARE INSULATED & GALVANIZED.
14. REMARKS: INDICATES ROOM LOCATION & SPECIFIC REMARKS
RELATING TO DOOR. 14. ALL DOOR FRAMES & HARDWARE TO BE RATED TO MATCH DOOR
LABEL.
GENERAL NOTES: INTERIOR GLAZING
15. SEE GLAZING NOTES THIS SHEET FOR GLASS LITE.
1. USE SAFETY GLAZING IN ALL DOORS.
16. ALL HM & ALUMINUM GLAZING STOPS TO BE FLUSH & SQUARE
A. C LABEL DOORS (45 MIN.) SHALL BE FIRE RATED. 1296 SQ. (NOT BEVELED) AND APPLIED W/F.H.M.S. (NO WRAP AROUND ON
IN. MAX. GLASS AREA "GLASS KITS" FOR HM GLAZING STOPS)
A1 A2 B1 B2 C1 C2 D1 E1 B. B LABEL (90 MIN.) GLASS SHALL BE FIRE RATED GLASS. 100
SQ. IN. MAX. GLASS AREA, WITH 12" MAX. DIMENSION 17. ALL FIRE-RATED DOORS SHALL HAVE FIRE-RATED CLOSERS;

DOOR TYPE - ELEVATIONS 2. ALL GLAZING IN FIRE-RATED HM OPENINGS TO BE FIRE-RATED 18. ALL DOOR CLOSER COVERS & COORDINATOR COVERS TO BE
1/8" = 1'-0" SAFETY GLAZING. FIELD PAINTED COLOR OF HM (U.N.O.). ALL DOOR CLOSERS ARE
ON ROOM SIDE OF DOOR (U.N.O.). NO DOOR CLOSERS ON
3. WIRE GLASS PATTERN TO BE SET 90°, NOT DIAGONAL. CORRIDOR SIDE UNLESS DOOR DIVIDES CORRIDOR.

4. USE SAFETY GLAZING IN FIXED OR OPERABLE LITES >18" IN 19. 3'-2" HIGH DOOR HANDLE TYP. OR MFR. STANDARD.
WIDTH ADJACENT TO A DOOR OR WITH SILLS BELOW 24" A.F.F.,
TO BE SAFETY GLAZING. (THIS IS IBC 2008 REVISE PER AHJ) 20. 3'-2" HIGH PUSH BAR @ PANIC HARDWARE OR MFR. STANDARD.

5. SEE A7-2 FOR TYPICAL FRAME PROFILES. 21. NO MANUFACTURER'S NAME PLATES ON ALUM. DOORS. G.C. TO
F1 F2 F3 REMOVE NAME PLATES ON DOORS AT NO ADDITIONAL COST.
6. SEE WALL TYPES FOR JAMB THROAT THICKNESS. Holabird & Root, LLC expressly disclaims any
22. 90 MINUTE LABELED DOORS UNLESS CALLED FOR SPECIFICALLY responsibility arising from any unauthorized use of these
FRAME TYPES - ELEVATIONS G1 = 1/4" CLEAR GLASS IN HARDWARE SPEC. FOR ASTRAGAL @ DOORS INTO ELEC. plans, drawings and notes. Any authorization must be in
SWITCH GEAR, MECH, & PUMP ROOMS AND EXTERIOR DOORS. writing.
1/8" = 1'-0"
GL-1 = 1" CLEAR INSULATED CLEAR GLASS
23. SEE TYPICAL HM DETAILS FOR NESTED STUDS This drawing copy may have been reproduced at a size
W1 = FIRE RATED GLASS different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.


5 5/8" 7 1/8"
TYP. NOTES @ 6" CMU PARTITION 1" x 5/8" REMOVABLE
SEE HJ-C11
FOR NOTES H.M. STOP WITH F.H.M.S.
6" CMU GLASS GLAZED AGAINST
FRAMED STOP

2" TYP.
8"X16" BOND BEAM W/ 2#5
BARS @ HEAD, 6" BEARING FOR FRAMES W/ 3 OR MORE HORIZONTAL
TYP. H.M. FRAME W/ 1/2" GPDW
ADJUSTABLE UL-RATED LEAFS USE 16 GAUGE BLINDS ROOM SIDE
WRAP-AROUND ENDS PARTITION
ANCHOR @ MASONRY JAMB NESTED STUDS FROM FLOOR AS REQUIRED

1 15/16", TYP.
GROUT SOLID @ RATED FRAME TO STRUCT. ABOVE (COORD. 5/8" GPDW
THROAT=PARTITION WIDTH
2"

1/2" (SEE SPEC. FOR NON RATED FRAME ANCHORS W.


FRAMES) 8 1/8" DETAILS)

1/2"
1/2" TYP. DIMENSION FOR H.M. FRAMES @ H.M. DOOR
6 5/8" 1" 2"
6" CMU
GPDW W/ DOUBLE

1/2"
STUDS
HJ-C11 HJ-C12 1 09/07/2018 ISSUED FOR BID

1 15/16", TYP.
1" = 1'-0" 1" = 1'-0" 2" , TYP. 2" , TYP. 5/8" 2" , TYP. No. Date Issue

5" MIN.
TYP. NOTES FOR H.M. FRAME
AT GPDW PARTITION Project Number 15849

4 7/8"
WALL @ 90º DEGREE IS OFFSET 6 1/8" TYP. H.M. FRAME PROFILES TYP. H.M. FRAME TYP. H.M. HEAD & SILL Drawn S. DENNY
2" FROM JAMB AS SHOWN (TYP.) SEE HJ-D1 1" = 1'-0" 1" = 1'-0" 1" = 1'-0" Checked K. BOYER
FOR NOTES
5/8" TYPE "X" GPDW (USG FIRE Proj. Arch./Eng. K. SCHUSTER
2" TYP.

CODE 'C')
GPDW W/ DOUBLE STUDS (3 5/8" 20 NEW GBDW FURRING
1/2" GAGE @ HEAD & JAMB) GPDW W/ DOUBLE STUDS EXISTING EXTERIOR CMU WALL
SPOT GROUT @ NON-RATED FRAMES
PER SPEC. Provident Hospital - Renal
2" TYP.

7 1/8"
5 7/8" GROUT SOLID @ RATED FRAMES
Dialysis Center
UL RATED ANCHORS @ RATED
WD DOOR 1" ACOUSTICAL GASKET/SEALANT
FRAMES SINGLE PANE GLASS
5/8" GPDW BET. MULLION & PARTITION WALL

HJ-D1 HJ-D2
1" = 1'-0" 1" = 1'-0" DRYWALL F-BEAD AT
1 3/4" ,TYP. EXISTING HM FRAME
EXPOSED ENDS OF ALL
GPDW NEW HM DOOR PANEL
4 1/2"

4 1/2"

SEE PLANS
SEE PLANS SEE HJ-D1
4 7/8" CLIP ANGLES ATTACHED TO HM
FOR NOTES SEE HJ-D1 FOR DOOR AND FRAME @ 24" O.C.
NOTES 1 3/4" 7/8"
430 East 51st Place
2 1/2" STUDS W/ 2/12" Chicago, Illinois 60615
STUDS CROSS DOUBLE 2 1/2" STUDS TYP. ALUM. FRAME PROFILES TYP. ALUM HEAD & SILL DETAIL OF EXTERIOR DOOR CLOSURE
BRACING @ 24" O.C. 1" = 1'-0" 1" = 1'-0" 1" = 1'-0"
Project Name
S.M. BRACE TO
SUPPORT STUDS OFF 4
SEALANT AND
6 3/8" BACKER ROD 5 7/8" 7/8" PARTITION DOOR SCHEDULE, BORROWED
SEALANT AND LIGHT SCHEDULE, ELEVATIONS,
BACKER ROD
& DETAILS
Sheet Name
HJ-D40 HJ-D43
1" = 1'-0" 1" = 1'-0" Drawing No. A7-2
A8-3

5
2
NARC-01

1 REUN-01 REUN-01 GLBH-01 EW-01

15 COSH-01 B
16 A8-2
FE-01 MED. PREP. FE-01
17 115 1' - 4"
DRDU-06
EXAM
106 6" 3' - 8" 2' - 9" 2' - 9" 2' - 10"
Department of Capital Planning & Policy
11
CH-4
224000.03 102800.09
P
Bureau of Asset Management
DISE-01

5"
14 12 102800.09 102800.08 Notice: This drawing has not been published and is the

3' - 0"
A8-2
TAEP-01 DI-01
102800.08 224000.05 sole property of Cook County. It is loaned to the borrower

3'-0"
13 PRIVATE 122413.01
6 for their confidential use only. In consideration of the loan
R
A8-6 PAT./ISOLATION 21 ACCESS DOOR of this drawing, the borrower promises and agrees to
STWB-01 4 117 return it upon request and agrees that it shall not be
A8-6 20 A8-2 18 reproduced, copied, loaned, or otherwise disposed of

5' - 0"
10

3'-1"
102800.08 DRCL-01
122413.01 directly or indirectly, nor used for any purpose other than
19 A8-2 3
TV-01 9 A8-2 7 6
102800.09 for which it is furnished, in whole or part.
A8-2 5 A8-2
TVAR-01
8 DI-01 DRCL-02 224000.03
NURSE

3'-2"
COSH-01 TYP

3' - 0"
GLBH-01 5 STATION GLBH-01 DI-01 3
BINS-01
A8-6 A8-6
TVAR-01
27 C D SOLID SURFACE
COUNTERTOP
24 A8-2 26 EW-01

5' - 0"
DRCL-01
25
COPM-01
SCHT-01
C C
RECEPTION TVAR-01
1 105 102800.08
A8-6 102800.08 102800.09
SCI-01 PROVIDE BLOCKING
224000.05 224000.03
WHERE NECESSARY FOR
2 TV MONITOR ARM
102800.09 4 COSH-01

DEPRESSED A8-2
SLAB AT SCALE

1
A8-1
EXAM & RECEPTION
1/4" = 1'-0" [REF: 1/ A2-1]
2
A8-1
NURSE STATION & MEDICAL PREP.
1/4" = 1'-0" [REF: 1/ A2-1] A8-1
3 PRIVATE PAT./ISOLATION
1/4" = 1'-0" [REF: 1/ A2-1]
4
A8-1
TYPICAL DIALYSIS STATION
1/4" = 1'-0" [REF: 1/ A2-1]

SOILED CLEAN
GLBH-01 STORAGE SUPPLY
118 119
CASU-01 B
CASU-02
B
12 A8-3

CASU-01
CASU-02

EW-01 Holabird & Root, LLC expressly disclaims any


TYP responsibility arising from any unauthorized use of these
3 DI-01 DI-01 DI-01
WATER plans, drawings and notes. Any authorization must be in
A8-6
TREATMENT writing.
GLBH-01
22
125
A8-2 This drawing copy may have been reproduced at a size
EW-02
different than originally drawn. The Owner and Architect
EQUIP. assume no responsibility for use of incorrect scale.
REPAIR COORDINATE WITH
PLUMBING DRAWINGS FOR Drawings are not to be scaled.
120
WATER TREATMENT LAYOUT
Not published - All rights reserved.

FE-01

EW-02 23 A8-2
C
LAB C
GLBH-01
REUN-01 121

5
A8-1
BIOHAZARD, CLEAN SUPPLY, EQUIP. REPAIR, & LAB
1/4" = 1'-0" [REF: 1/ A2-1]
6
A8-1
WATER TREATMENT
1/4" = 1'-0" [REF: 1/ A2-1]
1 09/07/2018 ISSUED FOR BID
No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

KEYNOTES LEGEND
REF#
102800.08 PAPER TOWEL DISPENSER
102800.09 SOAP DISPENSER
122413.01 MANUALLY OPERATED ROLLER SHADES
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/
PIPE COVER 430 East 51st Place
224000.05 LAVATORY - DROP-IN SINK Chicago, Illinois 60615

*SEE Q SERIES FOR OWNER


Project Name
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS
INTERIOR ENLARGED PLANS
*SEE A6-1 FOR MOUNTING HEIGHTS
AND GENERAL NOTES FOR WALL
MOUNTED ITEMS Sheet Name

Drawing No. A8-1


3
5
A8-6
A8-6

10 1/2"
3' - 0" 3' - 6" 3' - 0" 4' - 6" 3' - 0" 4' - 6" 3' - 0" 4' - 6" 3' - 0" ± 5' - 3" 3' - 6" 3' - 0" 4' - 6" 3' - 0" 4' - 6" 1' - 0" 3' - 0" 4' - 6" 3' - 0" 5' - 0" 3' - 0" 5' - 0" 3' - 0" ± 4' - 6"
BUTT GLAZED
TVAR-01 TVAR-01 TVAR-01 GLASS SPLASH
OPEN
GUARD 102800.09
1' - 10" SS1 102800.08

3 TYP 102800.08 224000.03


Department of Capital Planning & Policy
102800.09 COSH-01
A8-6
SCI-01
WP1
Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
102800.09 WP1
1/2" ALUM. WP2 DIALYSIS WALL T.V. ON ARTICULATING WP2 WP2 END PANEL WALL BASE, TYP. for their confidential use only. In consideration of the loan
224000.03 WALL BASE, TYP.
REVEAL TYP. BOX, TYP. ARM, TYP. of this drawing, the borrower promises and agrees to
102800.08 SCALE READOUT return it upon request and agrees that it shall not be
MOUNTED ON reproduced, copied, loaned, or otherwise disposed of
ADJACENT WALL directly or indirectly, nor used for any purpose other than

1
A8-2
TREATMENT AREA - SOUTH
1/4" = 1'-0" [REF: 1/ A2-1]
2
A8-2
TREATMENT AREA - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
3
A8-2
TREATMENT AREA - NORTH
1/4" = 1'-0" [REF: 1/ A2-1]
4
A8-2
NURSE STATION - EXT. EAST
1/4" = 1'-0" [REF: 1/ A2-1]
for which it is furnished, in whole or part.

Sim Sim Sim


4 12 4 4 5 4
A8-6 A8-4 A8-6 A8-6 A8-6 A8-6

SCHT-01 TV-02
OPEN OPEN OPEN OPEN
BUTT GLAZED
GLASS SPLASH BUTT GLAZED
OPEN BUTT GLAZED 5 Sim OPEN
GUARD OPEN GLASS SPLASH OPEN OPEN A8-6
GUARD SS1 SS1 GLASS SPLASH GLBH-01 SOLID SURFACE
SS1 GLBH-01
EW-01 GUARD COUNTERTOP
OPEN EW-01
102800.09
SOLID SURFACE AND CAP
102800.08
EW-01 COUNTERTOP
OPEN 224000.05 OPEN OPEN SCI-01 AND CAP SCALE SCI-01 OPEN
224000.03
READOUT
WP1 SOLID SURF. PL1 WP1 WP1 PL1 WP1 WALL BASE, WP1 PL1 WALL BASE,
224000.03 WALL BASE, END PANEL PL1 WP1
SILL, TYP. TYP. 6 Sim TYP. TYP.
A8-6 WALL BASE,
TYP.

5
A8-2
NURSE STATION - EXT. NORTH
1/4" = 1'-0" [REF: 1/ A2-1]
6
A8-2
NURSE STATION - EXT. SOUTH
1/4" = 1'-0" [REF: 1/ A2-1]
7
A8-2
NURSE STATION - INT. NORTH
1/4" = 1'-0" [REF: 2/ A8-1]
8
A8-2
NURSE STATION - INT. EAST
1/4" = 1'-0" [REF: 2/ A8-1]
9
A8-2
NURSE STATION - INT. SOUTH
1/4" = 1'-0" [REF: 2/ A8-1]
Sim Sim
6 5 2
A8-6 A8-4 A8-4 Sim Sim Sim
4 1 3
2' - 8" 2' - 6" 10" A8-4 A8-4 A8-4
AUDIO/VISUAL ALARM SOFFIT FLUSH
2' - 6" 2' - 6" 2' - 6" 2' - 6" 1' - 9" W/ FACE OF
CLOCK VIDEO SOFFIT OR SOFFIT OR F9.2 CABINETS
TV-02 PLAM PANEL PLAM PANEL POWER
GLAZING IN LIGHT SWITCH UNDER
ALUMINUM HEALTH MONITOR CABINET LIGHT

2' - 6"

2' - 6"

2' - 6"
THERMOSTAT NARC-01
CH-4
3' - 10"

STOREFRONT
9' - 11 1/2"

COSH-01 DISPLAY
DISE-01
CH-4 WALL PHONE DATA GLBH-01
BUTT GLAZED GLASS

2' - 2"

2' - 2"

2' - 2"
CHAIR RAIL

7' - 6"
SPLASH GUARD HAND SANITIZER POWER DATA GLBH-01 COSH-01
FE-01

4' - 6"
POWER Holabird & Root, LLC expressly disclaims any
3' - 8"

3' - 6"

2' - 10"

2' - 10"

2' - 10"
SOLID SURFACE WALL BASE, TYP. REUN-01 REUN-01 responsibility arising from any unauthorized use of these
1' - 6"

COUNTERTOP plans, drawings and notes. Any authorization must be in


AND CAP writing.
2' - 0" 6" 4' - 0" 6" 4' - 3" 1' - 3"1' - 3"1' - 3" 2' - 6" 1' - 3"
WALL BASE, 2' - 0"
TYP. This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

10 NURSE STATION - INT. WEST


A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
11 EXAM - WEST
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
12 EXAM - NORTH
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
13 EXAM - EAST
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
14 EXAM - SOUTH
A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
15 MEDICAL PREP. - WEST
A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
Not published - All rights reserved.

TYP
3
6 A8-6
A8-6
9' - 2"
EQ 2" EQ 2" EQ 2" EQ
3' - 6"
GLAZING IN ALUM.
STOREFRONT SOFFIT OR GLAZING IN ALUM.
PLAM PANEL 102800.08
STOREFRONT
102800.09
TVAR-01 ALUMINUM STOREFRONT
3' - 6"

3' - 6"

224000.03
WITH SAFETY GLAZING

8' - 0"

8' - 0"
TVAR-01 COSH-01 TVAR-01
UNDER 224000.03 DIALYSIS WALL
CABINET BOX, TYP. 1 09/07/2018 ISSUED FOR BID
LIGHT
3' - 8"

3' - 8"

No. Date Issue


DRDU-06 REUN-01 DRDU-06 WP2

4'-6" 3'-0"
Project Number 15849
WALL BASE, TYP. WALL BASE, TYP. WP2 WALL BASE, TYP.
WALL BASE, TYP. Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER
16 MEDICAL PREP. - SOUTH
A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
17 MEDICAL PREP. - EAST
A8-2 1/4" = 1'-0" [REF: 2/ A8-1]
18 PRIVATE PAT./ISOLATION - NORTH
A8-2 1/4" = 1'-0" [REF: 3/ A8-1]
19 PRIVATE PAT./ISOLATION - EAST
A8-2 1/4" = 1'-0" [REF: 2/ A6-2]
20 PRIVATE PAT./ISOLATION - SOUTH
A8-2 1/4" = 1'-0" [REF: 3/ A8-1]
21 PRIVATE PAT./ISOLATION - WEST
A8-2 1/4" = 1'-0" [REF: 2/ A6-2]

Sim TYP Sim Sim Sim Sim Provident Hospital - Renal


3
A8-2 INTERIOR ELEVATIONS

3 6 3 2 9 4
A8-4 A8-6 A8-4 A8-4 A8-6 A8-4 A8-4 Dialysis Center
3' - 0" 2' - 6" 2' - 6" 4' - 0" 3' - 0" 3' - 0" 2' - 6" 2' - 4 1/2" 3' - 0" 2' - 6" 2' - 9 1/2"

SOFFIT FLUSH SOFFIT FLUSH


SOFFIT FLUSH W/FACE OF KEYNOTES LEGEND
SOFFIT FLUSH W/ FACE OF W/FACE OF
CABINETS SOFFIT FLUSH
W/ FACE OF CABINETS CABINETS REF#
CABINETS 2 TYP W/FACE OF
2' - 6"

2' - 6"

CABINETS 102800.08 PAPER TOWEL DISPENSER


2' - 6"

2' - 6"

2' - 6"
A8-6
102800.09 SOAP DISPENSER
UNDER CABINET
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/
2' - 2"

2' - 2"

EW-02 LIGHT GLBH-01 EW-02 UNDER CABINET


2' - 0"

2' - 0"

2' - 0" UNDER PIPE COVER


LIGHT UNDER TACKBOARD 430 East 51st Place
DIALYSIS WALL BINS-01
BINS-01 CABINET
CABINET 224000.05 LAVATORY - DROP-IN SINK Chicago, Illinois 60615
BOX, TYP. EYE WASH LIGHT
2' - 10"

2' - 10"

COPM-01 COPM-01 LIGHT COPM-01


2' - 6"

2' - 6"

2' - 6"

2' - 6"

REUN-01 *SEE Q SERIES FOR OWNER


Project Name
WP2 EQUIPMENT SCHEDULE REFERENCED
1' - 6" 3' - 6" 2' - 6" 2' - 6" 2' - 9 1/2"
3' - 6" 1' - 6" 3' - 1 1/2" WALL BASE, TYP. WALL BASE, TYP. IN THESE PLANS
WALL BASE, TYP. INTERIOR ELEVATIONS
*SEE A6-1 FOR MOUNTING HEIGHTS
09/07/2018 ISSUED FOR BID

AND GENERAL NOTES FOR WALL


MOUNTED ITEMS Sheet Name
22 EQUIP. REPAIR - SOUTH 23 LAB - SOUTH 24 RECEPTION - SOUTH 25 RECEPTION - EAST 26 RECEPTION - NORTH 27 RECEPTION - WEST
A8-2 1/4" = 1'-0" [REF: 5/ A8-1] A8-2 1/4" = 1'-0" [REF: 5/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1] A8-2 1/4" = 1'-0" [REF: 1/ A8-1]
Drawing No. A8-2
TV-01 TV-02

8' - 0"
CH-12

5' - 0"
CAV-01 CAV-01 CAV-01 OPEN OPEN

DEAE-01
CASU-03
Department of Capital Planning & Policy
WALL BASE, TYP. WALL BASE, TYP. WALL BASE, TYP. WALL BASE, TYP. Bureau of Asset Management
CLEAN EXISTING CMU AT WALL BASE, TYP. Notice: This drawing has not been published and is the
FORMER PLANTER AREA sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
1
A8-3
CONFERENCE - NORTH
1/4" = 1'-0" [REF: 1/ A2-1]
2
A8-3
CONFERENCE - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
3
A8-3
CONFERENCE - SOUTH
1/4" = 1'-0" [REF: 1/ A2-1]
4
A8-3
CONFERENCE - WEST
1/4" = 1'-0" [REF: 1/ A2-1]
5
A8-3
CORRIDOR 100C - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
Sim Sim Sim for which it is furnished, in whole or part.
3 7 8 Sim
A8-4 A8-4 A8-4 10
10'-6"
A8-4
CLOCK

3' - 0" 2' - 6" 1' - 6" 2' - 6"

1' - 5"
064116.02
UNDER
CABINET LIGHT

2' - 6"
CH-4 TV-01
MICRO-01 MICRO-01
P.LAM
COUNTERTOP

7' - 7"
W/BACKSPLASH

5' - 0"
REFU-01

WALL BASE, TYP. 3' - 0" 2' - 0" 2' - 0" 2' - 6" WALL BASE, TYP. WALL BASE, TYP.

6
A8-3
CORRIDOR 100C - WEST
1/4" = 1'-0" [REF: 1/ A2-1]
7
A8-3
STAFF - NORTH
1/4" = 1'-0" [REF: 1/ A2-1] A8-3
8 STAFF - EAST
1/4" = 1'-0" [REF: 1/ A2-1]
9
A8-3
STAFF - WEST
1/4" = 1'-0" [REF: 1/ A2-1]

Sim
2 11
A8-6 A8-4
CLOCK

TV-01
TB-04 TB-03
224000.03
LOCKERS GLBH-01
OPEN
BEYOND CASU-02 CASU-02

PL1
WALL BASE, TYP. WALL BASE, TYP. WALL BASE, TYP. Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.
10 WAITING ROOM - NORTH 11 WAITING ROOM - WEST
A8-3 1/4" = 1'-0" [REF: 1/ A2-1] A8-3 1/4" = 1'-0" [REF: 1/ A2-1] 12 SOILED STORAGE - SOUTH
A8-3 1/4" = 1'-0" [REF: 5/ A8-1]
This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

KEYNOTES LEGEND
REF#
064116.02 PLASTIC LAMINATE LOCKER.
224000.03 LAVATORY - SINGLE ACCESSIBLE - WALL MOUNTED W/ 430 East 51st Place
PIPE COVER Chicago, Illinois 60615

*SEE Q SERIES FOR OWNER


Project Name
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS
INTERIOR ELEVATIONS
*SEE A6-1 FOR MOUNTING HEIGHTS
AND GENERAL NOTES FOR WALL
MOUNTED ITEMS Sheet Name

Drawing No. A8-3


1'-0"
1'-0" 1'-0"

1'-0"

VARIES
SCHEDULED CEILING

VARIES
SCHEDULED CEILING SCHEDULED CEILING

VARIES
VARIES
PLAM CLOSURE PANEL SCHEDULED CEILING
PLAM CLOSURE PANEL

WOOD BLOCKING AS REQUIRED, TYP. PLAM CLOSURE PANEL


PLAM CLOSURE PANEL
WOOD BLOCKING AS REQUIRED, TYP.
WOOD BLOCKING AS REQUIRED, TYP. WOOD BLOCKING AS REQUIRED, TYP.

SEE ELEVATION

VARIES, SEE ELEVATION


2' - 6"

METAL SHELF SUPPORTS

2'-0" OR 2'-6"
METAL SHELF SUPPORTS
2' - 8"

METAL SHELF SUPPORTS (2) 3/4" BLACK MELAMINE


METAL SHELF SUPPORTS Department of Capital Planning & Policy
(2) 3/4" WHITE MELAMINE
ADJUSTABLE SHELVES (2) 3/4" BLACK MELAMINE Bureau of Asset Management

2' - 6"
ADJUSTABLE SHELVES

2' - 6"
(2) 3/4" BLACK MELAMINE ADJUSTABLE SHELVES

2' - 8"
ADJUSTABLE SHELVES WALL MOUNTED CABINET Notice: This drawing has not been published and is the
WALL MOUNTED CABINET CONSTRUCTED OF 3/4" WHITE WALL MOUNTED CABINET sole property of Cook County. It is loaned to the borrower
CONSTRUCTED OF 3/4" WHITE WALL MOUNTED CABINET MELAMINE INTERIOR AND PLASTIC CONSTRUCTED OF 3/4" WHITE
2"

MELAMINE INTERIOR AND PLASTIC CONSTRUCTED OF 3/4" WHITE LAMINATE VENEER EXTERIOR ON for their confidential use only. In consideration of the loan
MELAMINE INTERIOR AND PLASTIC
LAMINATE VENEER EXTERIOR ON
VARIES, SEE ELEVATION

MELAMINE INTERIOR AND PLASTIC ALL EXPOSED SIDES LAMINATE VENEER EXTERIOR ON of this drawing, the borrower promises and agrees to
ALL EXPOSED SIDES LAMINATE VENEER EXTERIOR ON ALL EXPOSED SIDES

2"
return it upon request and agrees that it shall not be

2"
ALL EXPOSED SIDES LOW PROFILE UNDER CABINET

SEE ELEVATION
LOW PROFILE UNDER CABINET reproduced, copied, loaned, or otherwise disposed of

VARIES, SEE ELEVATION


LIGHT WHERE INDICATED ON RCP GPDW SURFACE
LIGHT WHERE INDICATED; SEE RCP
2' - 1"
GPDW SURFACE directly or indirectly, nor used for any purpose other than
1 1/2"

1-1/2" SOLID SURFACE 2' - 1" GPDW SURFACE 2' - 1" 1-1/2" SOLID SURFACE COUNTERTOP for which it is furnished, in whole or part.
SCHEDULED COUNTERTOP -
COUNTERTOP W/ BACKSPLASH / PROVIDE BACKSPLASH/SIDESPLASH 2' - 1"
4"

SIDESPLASH WHERE INDICATED; WHERE THE COUNTER IS IN REFER TO ELEVATIONS FOR


SEE ELEVATIONS SCHEDULED COUNTERTOP - COUNTER FINISH. 1-1/2" SOLID

4"
CONTACT W/ ADJACENT WALL
PROVIDE BACKSPLASH/SIDESPLASH SURFACE TO BE USED WHERE
6"

5 1/2"
1 7/8" 4"
WHERE THE COUNTER IS IN

2" 5"
ADA COMPLIANT DROP-IN SINK NOTED.
(2) 3/4" WHITE MELAMINE W/ REAR DRAIN OUTLET CONTACT W/ ADJACENT WALL
ADJUSTABLE SHELVES
KNEE

VARIES; SEE ELEVATIONS


SPACE MAY BE UTILIZED FOR

2' - 6" OR 2' - 10"


SINK W/ REAR DRAIN OUTLET SPACE
2' - 10"

EQUIPMENT OR ROLLING
1' - 10 1/2"

CABINETS

1' - 6"
2' - 10"
BASE CABINET CONSTRUCTED REMOVABLE 3/4" MDF PANEL W/
OF 3/4" WHITE MELAMINE PLASTIC LAMINATE EXPOSED

2' - 10"
2' - 8 1/8"
INTERIOR AND PLASTIC SIDES & EDGES; PROVIDE Z- CONCEALED 1-1/2" x 1-1/2" x
LAMINATE VENEER EXTERIOR CLIPS FOR PANEL REMOVAL; NO BASE CABINET CONSTRUCTED 3/16" STEEL BRACKET @ 48" ON
ON ALL EXPOSED SIDES EXPOSED FASTENERS OF 3/4" WHITE MELAMINE CENTER
INTERIOR AND PLASTIC WALL TILE - REFER TO
4"

9"
REMOVABLE PANEL W/ BASE AS LAMINATE VENEER EXTERIOR ELEVATION
3" 1' - 9" SCHEDULED ON ALL EXPOSED SIDES
2' - 0" 11" 6" 2' - 0"

1
A8-4
SECTION DETAIL - BASE CABINET W/ TOP DRAWER
N.T.S.
2
A8-4
SECTION DETAIL - BASE CABINET W/ ADA SINK
N.T.S. A8-4
3 SECTION DETAIL - BASE CABINET W/ SINK
N.T.S.
4
A8-4
SECTION DETAIL - CONCEALER BRACKET
N.T.S.

1'-0" 1'-0" 1'-0"

VARIES
VARIES SCHEDULED CEILING SCHEDULED CEILING SCHEDULED CEILING

VARIES
PLAM CLOSURE PANEL

PLAM CLOSURE PANEL PLAM CLOSURE PANEL


WOOD BLOCKING AS REQUIRED, TYP.
WOOD BLOCKING AS REQUIRED, TYP. WOOD BLOCKING AS REQUIRED, TYP.
WALL MOUNTED CABINET
METAL SHELF SUPPORTS METAL SHELF SUPPORTS
CONSTRUCTED OF 3/4" WHITE

2' - 6"
2' - 8"
(2) 3/4" BLACK MELAMINE MELAMINE INTERIOR AND PLASTIC (2) 3/4" BLACK MELAMINE
ADJUSTABLE SHELVES LAMINATE VENEER EXTERIOR ON ADJUSTABLE SHELVES
2' - 6"

2' - 6"
2' - 8"

2' - 8"
ALL EXPOSED SIDES
WALL MOUNTED OPEN-SHELF WALL MOUNTED CABINET
CABINET CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4" WHITE
WHITE MELAMINE INTERIOR AND MICROWAVE SHELF MELAMINE INTERIOR AND PLASTIC

2"
PLASTIC LAMINATE VENEER LAMINATE VENEER EXTERIOR ON
EXTERIOR ON ALL EXPOSED SIDES ALL EXPOSED SIDES

VARIES, SEE ELEVATION


2"

2"
GPDW SURFACE GPDW SURFACE
LOW PROFILE UNDER CABINET
LOW PROFILE UNDER CABINET LIGHT WHERE INDICATED; SEE RCP LOW PROFILE UNDER CABINET Holabird & Root, LLC expressly disclaims any
LIGHT WHERE INDICATED; SEE RCP LIGHT WHERE INDICATED; SEE RCP
responsibility arising from any unauthorized use of these

1 1/2"
GPDW SURFACE GPDW SURFACE
2' - 1" 2' - 1" 2' - 1" 2' - 1" plans, drawings and notes. Any authorization must be in
1 1/2"

1 1/2"

1 1/2"
1-1/2" SOLID SURFACE 1-1/2" SOLID SURFACE 1-1/2" SOLID SURFACE 1-1/2" SOLID SURFACE writing.

4"
COUNTERTOP W/ BACKSPLASH / COUNTERTOP W/ BACKSPLASH / COUNTERTOP W/ BACKSPLASH / COUNTERTOP W/ BACKSPLASH /
4"

4"

4"
SIDESPLASH WHERE INDICATED; SIDESPLASH WHERE INDICATED; SIDESPLASH WHERE INDICATED; SIDESPLASH WHERE INDICATED;
SEE ELEVATIONS SEE ELEVATIONS SEE ELEVATIONS SEE ELEVATIONS This drawing copy may have been reproduced at a size
DRAWERS CONSTRUCTED DRAWERS CONSTRUCTED DRAWERS CONSTRUCTED DRAWERS CONSTRUCTED
different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.

2' - 6" OR 2' - 10"


OF 3/4" WHITE MELAMINE OF 3/4" WHITE MELAMINE OF 3/4" WHITE MELAMINE OF 3/4" WHITE MELAMINE
2' - 6" OR 2' - 10"

2' - 6" OR 2' - 10"

2' - 4 1/2"
SIDES WITH 1/2" WHITE SIDES WITH 1/2" WHITE SIDES WITH 1/2" WHITE SIDES WITH 1/2" WHITE Drawings are not to be scaled.
2' - 0 1/2"

2' - 0 1/2"

2' - 0 1/2"
MELAMINE BOTTOM MELAMINE BOTTOM MELAMINE BOTTOM MELAMINE BOTTOM

2' - 6"
SEE ELEVATIONS FOR SEE ELEVATIONS FOR SEE ELEVATIONS FOR SEE ELEVATIONS FOR
NUMBER OF DRAWERS NUMBER OF DRAWERS NUMBER OF DRAWERS NUMBER OF DRAWERS Not published - All rights reserved.
BASE CABINET BASE CABINET BASE CABINET BASE CABINET
CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4" CONSTRUCTED OF 3/4"
WHITE MELAMINE INTERIOR WHITE MELAMINE INTERIOR WHITE MELAMINE INTERIOR WHITE MELAMINE INTERIOR
AND PLASTIC LAMINATE AND PLASTIC LAMINATE AND PLASTIC LAMINATE AND PLASTIC LAMINATE
4"

4"

4"

4"
VENEER EXTERIOR ON ALL VENEER EXTERIOR ON ALL VENEER EXTERIOR ON ALL VENEER EXTERIOR ON ALL
3" 1' - 9" EXPOSED SIDES 3" 1' - 9" EXPOSED SIDES 3" 1' - 9" EXPOSED SIDES 3" 1' - 9" EXPOSED SIDES
2' - 0" 2' - 0" 2' - 0" 2' - 0"

SECTION DETAIL - BASE CABINET W/ DRAWERS & UPPER SECTION DETAIL - BASE CABINET W/ DRAWERS & UPPER CABINET
5
A8-4
SECTION DETAIL - BASE CABINET W/ DRAWERS (BASE ONLY)
N.T.S.
6
A8-4
SHELVING
N.T.S. A8-4
7 W/ MICROWAVE SHELF
N.T.S.
8
A8-4
SECTION DETAIL - BASE CABINET W/ DRAWERS & UPPER CABINET
N.T.S.

1 09/07/2018 ISSUED FOR BID


1'-0" No. Date Issue

Project Number 15849


SCHEDULED CEILING
Drawn S. DENNY
VARIES

VARIES

VARIES

Checked K. BOYER
1' - 0" 1' - 0"
PLAM CLOSURE PANEL Proj. Arch./Eng. K. SCHUSTER
WOOD BLOCKING AS REQUIRED, TYP.

METAL SHELF SUPPORTS


(2) 3/4" BLACK MELAMINE
ADJUSTABLE SHELVES 3/4" REVEAL 3/4" REVEAL
2' - 6"

WALL MOUNTED CABINET


Provident Hospital - Renal
CONSTRUCTED OF 3/4" WHITE
MELAMINE INTERIOR AND PLASTIC HOOKS AT BACK AND Dialysis Center
LAMINATE VENEER EXTERIOR ON SIDES OF LOCKER
ALL EXPOSED SIDES

GPDW SURFACE LOCK LOCK, (TYP.)


2'-1"
SCHEDULED PARTITION SCHEDULED PARTITION SCHEDULED COUNTERTOP -
LOW PROFILE UNDER CABINET
5' - 6 1/8"

LIGHT WHERE INDICATED; SEE RCP PROVIDE BACKSPLASH/SIDESPLASH


LOCKERS CONSTRUCTED OF 3/4" LOCKERS CONSTRUCTED OF 3/4"
5' - 8"

5' - 8"

WHERE THE COUNTER IS IN


6' - 0"

6' - 0"

GPDW SURFACE WHITE MELAMINE INTERIOR AND WHITE MELAMINE INTERIOR AND

4"
CONTACT W/ ADJACENT WALL
PLASTIC LAMINATE VENEER PLASTIC LAMINATE VENEER
EXTERIOR ON ALL EXPOSED EXTERIOR ON ALL EXPOSED

5"
ADA COMPLIANT DROP-IN SINK
SIDES SIDES W/ REAR DRAIN OUTLET

8"
4' - 6"

HOOKS AT BACK AND SIDE PANEL WHERE COUNTER IS


SIDES OF LOCKER NOT IN CONTACT W/ ADJACENT WALL 430 East 51st Place
Chicago, Illinois 60615

2' - 10"
GPDW SURFACE
LOCK LOCK, (TYP.)

Project Name

TYPICAL CASEWORK DETAILS


4"

4"

4" 4"

9
A8-4
SECTION DETAIL - UPPER CABINET
N.T.S.
10 SECTION DETAIL - DOUBLE LOCKERS
A8-4 N.T.S.
11 SECTION DETAIL - SMALL LOCKERS
A8-4 N.T.S.
12 SECTION DETAIL - ADA SINK
A8-4 N.T.S.
Sheet Name

Drawing No. A8-4


1'' MIN.
PLAM FACED SCRIBE
CUT TO FIT

FACE OF WALL

TRACK BACKING AT TOP, SEE


PLAN AT CABINET SCRIBE BACKING TYPE DETAILS
A
COUNTERTOP. SEE SCREWS @ 12'' O.C., AND SCREWS @ 16'' O.C., 2 PER
ELEVATION FOR MORE

VERIFY
WITHIN 3'' FROM ENDS BLOCKING MIN. AND 4'' FROM
INFORMATION END TYP. (OMIT IF CABINET
HAS INTEGRAL BASE)
Department of Capital Planning & Policy

SEE ELEVATIONS
2''X4'' WOOD BLOCKING, USE

7'-2'' MAX
CEILING AS
Bureau of Asset Management

HEIGHT
PRESSURE TREATED @ SLABS

FASCIA
3" ± SCHEDULED ON GRADE. LOCATE BLOCKING
PLAM FACED FILLER AT FRONT AND OPEN ENDS, OR

1"
3" TO BLOCKING AT 4'-0'' O.C.
Notice: This drawing has not been published and is the
HEAVY DUTY EPOXY CUT TO FIT
sole property of Cook County. It is loaned to the borrower

4"
COATED METAL SUPPORT GYPSUM SCREWS @ 16'' O.C., 4''
BRACKET MOUNT TO WALL BOARD FACE OF WALL FROM ENDS for their confidential use only. In consideration of the loan
STUDS, PAINT TO MATCH WALL FILLER CUT TO FIT WALL BASE; SEE ID SHEETS
of this drawing, the borrower promises and agrees to
SEE BASE CABINET ANCHORAGE
1" DETAIL "D" SHIM BY CABINET INSTALLER
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
PLAN AT CABINET FILLER directly or indirectly, nor used for any purpose other than
2
A8-5
SECTION DETAIL - COUNTERTOP CONCEALED SUPPORT BRACKET
1" = 1'-0"
B
C
FLOOR CABINET TALLER THAN 3'-0''
D
BASE CABINET ANCHORAGE
for which it is furnished, in whole or part.

3/4''=1'-0'' 1 1/2''=1'-0''
SECTION AT GYP BD SOFFIT / FASCIA
A

SEE ELEVATIONS
SCREWS @ 16'' O.C. W/ MIN. 1/2'' TRACK BACKING AT TOP, SEE
PENETRATION FRONT & BACK BACKING TYPE DETAILS

HEIGHT
FASCIA
CEILING AS TYP TOP & BOTTOM SCREWS @ 12'' O.C., AND
SCHEDULED WITHIN 3'' FROM ENDS, TYP TOP
SCREWS @ 16'' O.C. & BOTTOM
SCRIBE AS REQD

2'' MIN.
BACKING PLATE, BACKING PLATE AT BOTTOM,
FASCIA MATERIAL SEE BACKING TYPE DETAILS SEE BACKING TYPE DETAILS
2' - 0" TYP U.N.O. 1" TO MATCH CABINET
SIDE & BACK SPLASH AT CONTRACTOR'S OPTION;
AS INDICATED ON 1" FACE
ON PLANS 1/2'' RADIUS U.N.O. BACKING PLATE W/ SCREWS
INTERIOR ELEVATIONS @ 16'' O.C. MAY BE SUBSTITUTED FOR
FLOOR CABINET CONNECTION
PLAM FACED FILLER
4"

CUT TO FIT SEE BASE CABINET ANCHORAGE


SEE INTERIOR
1 1/2"

SEALANT SECTION AT PLAM SOFFIT / FASCIA DETAIL "D"


ELEVATIONS

FACE OF WALL
SUPPORT FRAME AS 1"
B
REQUIRED 2' - 0" BASE CABINET DEPTH U.N.O.
2'' MIN. BASE CABINET UPPER CABINET
A 3/4''=1'-0''
B 3/4''=1'-0''
PLAN AT CABINET FILLER - INSIDE CORNER
C

1
A8-5
SECTION DETAIL - TYPICAL COUNTERTOP INFORMATION
1" = 1'-0"
3
A8-5
SOFFIT / FASCIA TYPES
3/4" = 1'-0"
4
A8-5
CABINET SCRIBE/ FILLER DETAILS
3/4" = 1'-0" A8-5
5 SECTION DETAIL - TYPICAL CABINET ANCHORAGE
3/4" = 1'-0"

POST SPACING TO BE CONFRIMED WITH


DENTAL SUPPLIER - 16" OC MAX
REQD BY ITEM
1'-4'' U.N.O. OR

3/4'' X 8'' X STUD SPACING


18 GA 1 1/4' X 1 1/4'' X 8'' SECTION FIRE RETARDANT TREATED PLYWOOD
METAL CLIP ANGLE 18 GA 1 1/4' X 1 1/4'' X 8''
METAL CLIP ANGLE

PLAN
VERIFY DIM

3/4'' X 8'' X STUD SPACING 4" X 4" 16" OC POST FOR DENTAL X-RAY ARM
TO FLOOR

FIRE RETARDANT TREATED MOUNTING - SUPPORT LOAD OF 1,500 LBS OFF


PLYWOOD CENTER. COORDINATE WITH MFG SPECS Holabird & Root, LLC expressly disclaims any
PLAN VIEW SECTION VIEW
responsibility arising from any unauthorized use of these
E WOOD PLATE / BLOCKING & BACKING plans, drawings and notes. Any authorization must be in
A PLATE / WOOD BACKING PLAN VIEW (SEE A FOR SIMILAR SECTION) writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
14 GA FABRICATED
FLUSH MOUNT
BACKING OPA-# Not published - All rights reserved.
0192

1/2'' MIN (4) #10 SMS TYP.


1'' MAX
METAL STUD:
3 5/8'' X 20 GA MIN
@ 16'' O.C., TYP.
6'' X 16 GA BACKING PLATE FASTEN TO STUDS W/ (3) # 6'' X 16 GA TRACK NOTCH AND FASTEN TO STUDS W/ (3) # 1. THIS BACKING IS FOR GRAB BARS AND EXTRA HEAVY SEE NOTES UNDER A FOR BACKING NOTES
10 X 3/4'' WAFER HEAD SELF DRILLING SCREWS PER 10 X 3/4'' WAFER HEAD SELF DRILLING SCREWS PER EQUIPMENT
STUD. ALL BACKING TO SPAN MIN OF (3) STUDS. STUD. ALL BACKING TO SPAN MIN OF (3) STUDS. 2. SEE BACKING PLATE TYPE B FOR ADDITIONAL NOTES
BACKING PLATE TO BE Fy=50 KSI STEEL BACKING TRACK TO BE Fy=50 KSI STEEL 1 09/07/2018 ISSUED FOR BID
ALTERNATE: PLYWOOD SIZED FOR LOAD
No. Date Issue
A PLATE BACKING: USE FOR FOLLOWING ITEMS B TRACK BACKING: USE FOR FOLLOWING ITEMS C ALTERNATE TO B E 4X4 POST: USE FOR FOLLOWING ITEMS
1. FLOOR MOUNTED BASE CABINETS 1. HANDRAILS AND GRAB BARS 1. LARGE MONITOR DISPLAYS
2. WALL MOUNTED DISPENSERS AND HARDWARE 2. FLOOR MOUNTED CABINETS GREATER THAN 1/2"
WEIGHING LESS THAN 40 LBS 3'-0'' IN HEIGHT 16 GA TRACK MAY BE SUBSTITUTED FOR
3. MIRRORS 3. WALL HUNG CABINETS GREATER THAN 15'' IN 1 1/4'' FLANGE W/O STIFFENER LIP AS Project Number 15849
4. BACKING AT THE BOTTOM OF WALL HUNG DEPTH AND AT THE TOP OF WALL HUNG SHOWN W/ THE FOLLOWING LIMITATIONS:
1/2"

CABINETS LESS THAN 15'' IN DEPTH CABINETS LESS THAN 15'' IN DEPTH 1. STUD SPACING IS 16'' O.C. OR LESS Drawn S. DENNY
6"

5. WALL PROTECTION: UPPER / LOWER CRASH 2. FOR 200 LBS LOADS MAX
RAILS, CHAIR RAILS 3. USE 14 GA TRACK AS SHOWN FOR
6. WHEN BACKING USED FOR ITEMS WEIGHING 20 GRAB BAR LOADS EQUAL TO 250 LBS Checked K. BOYER
LBS OR LESS, BACKING WILL NEED ONL ATTACH Fy=50KSI STEEL
TO TWO STUDS. THIS DOES NOT APPLY TO Proj. Arch./Eng. K. SCHUSTER
HANDRAILS AND GRAB BARS
D ALTERNATE TO B

6
A8-5
TYPICAL BACKING DETAILS
1 1/2" = 1'-0"
Provident Hospital - Renal
Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

TYPICAL CASEWORK DETAILS

Sheet Name

Drawing No. A8-5


1' - 8"
V.I.F.

EXISTING CMU HEADER

1/2" ALUM. REVEAL BOTH SIDES

1 1/2"
SOLID SURFACE FRAME 1' - 4"
5" 1"
GROMMET SOLID SURFACE
BUTT GLAZED GLASS 1' - 0"
ACCESS COUNTERTOP BEYOND
EXISTING CMU

/2"
DOOR

11
COLUMN ENCLOSURE FINISHED WALL BEYOND

1 1/4"
1/2" REVEAL BOTH SIDES CONTINUOUS SOLID SURFACE
STAINLESS COUNTERTOP WITH
Department of Capital Planning & Policy
GPDW WALL BELOW STEEL HINGE EASED EDGE Bureau of Asset Management
Notice: This drawing has not been published and is the

1' - 0 3/4"
VOICE HOLE GROMMET - COORDINATE

3" Ø
sole property of Cook County. It is loaned to the borrower

1' - 10 1/2"
SOLID SURFACE W/ OUTLET LOCATIONS
COUNTERTOP 1/2" REVEAL SS1 for their confidential use only. In consideration of the loan
CABLE/ELECTRICAL of this drawing, the borrower promises and agrees to
RACEWAY AS REQUIRED - SS1
return it upon request and agrees that it shall not be
COORDINATE W/ELECTRICAL reproduced, copied, loaned, or otherwise disposed of
TRANSACTION OPENING 4"x12" directly or indirectly, nor used for any purpose other than
2 POWER/DATA OUTLET
for which it is furnished, in whole or part.

4' - 4"

4"
A8-6 SOLID SURFACE COUNTERTOP SCHEDULED SUPPORT
BACKPOST SUPPORT

1 1/2"

3' - 4"
2" 1/2" ALUM. REVEAL BOTH SIDES AS REQUIRED
CABLE/ELECTRICAL RACEWAY REMOVEABLE
BUTT GLAZED GLASS DIALYSIS BOX
ACCESS PANEL
BACKPOST SUPPORT AS REQUIRED

2' - 6"
1 1/2"
SOLID SURFACE
COUNTERTOP POWER/DATA OUTLET WP2
GPDW ON

1' - 6 1/2"
LAMINATE PANEL

2' - 6"
3 5/8" STUDS
GPDW WALL
GPDW GPDW ON PL1
BELOW
2 1/2" STUDS
GPDW PARTITION WALL BASE
WALL BASE
1/2" REVEAL
BOTH SIDES
1' - 0" 1' - 7"
SOLID SURFACE
FRAME

1
A8-6
PLAN AT RECEPTION DESK
1" = 1'-0" [REF: 1/ A8-1]
2
A8-6
SECTION AT RECEPTION DESK
1 1/2" = 1'-0" [REF: 24/ A8-2]
3
A8-6
SECTION DETAIL - DIALYSIS BOX
1 1/2" = 1'-0" [REF: 4/ A8-1]
4
A8-6
NURSE WORK STATION @ PLAM PANEL
1 1/2" = 1'-0" [REF: 2/ A8-1]

BUTT GLAZED GLASS


BUTT GLAZED GLASS SPLASH GUARD
SPLASH GUARD
SS1 3/4" TYP. SOLID
SOLID
SURFACE CAP
SURFACE CAP
3/4"

1/2" REVEAL
1 1/4"

BOTH SIDES
1/2" REVEAL
BOTH SIDES
GROMMET -
GROMMET - COORDINATE WITH
1' - 2"

1' - 2"
COORDINATE WITH OUTLET LOCATIONS
OUTLET LOCATIONS
SS1

1 1/2"
1 1/2"

POWER/DATA OUTLET POWER/DATA OUTLET

CONCEAL 1 1/2" x CONCEAL 1 1/2" x


1 1/2" x 3/8" STEEL 1 1/2" x 3/8" STEEL
BRACKET BRACKET 1'-6" Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
PLAM PANEL BEYOND plans, drawings and notes. Any authorization must be in
1'-1 1/2"

writing.

This drawing copy may have been reproduced at a size


PL1 different than originally drawn. The Owner and Architect
2' - 6"

2' - 6"
assume no responsibility for use of incorrect scale.
GPDW ON 3 GPDW ON 3 Drawings are not to be scaled.
5/8" STUDS 5/8" STUDS
Not published - All rights reserved.
WALL BASE, TYP. WALL BASE, TYP.

5
A8-6
NURSE WORK STATION @ PARTIAL WALL
1 1/2" = 1'-0" [REF: 2/ A8-1]
6
A8-6
NURSE WORK STATION @ CURTAIN WALL
1 1/2" = 1'-0" [REF: 2/ A8-1]

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

CASEWORK DETAILS

Sheet Name

Drawing No. A8-6


GENERAL NOTES: ROOM & BUILDING IDENTIFICATION SIGNAGE SIGNAGE TYPE SCHEDULE
PLAN ROOM SIGN SIGN
TYPE 1: TYPE 2: 1. SEE CBC 2017 AND NFPA 2012 FOR ALL CODE COMPLIANT SIGNAGE REQUIREMENTS; EMERGENCY PLAN SIGNAGE, ETC. PLAN ROOM NAME NUMBER SIGN NAME NUMBER TYPE PLACMENT LOCATION
NUMBER ONLY SIGN W/ ROOM NAME & NUMBER TREATMENT AREA 1 1 9 WALL ABOVE COORESPONDING
2. ROOM SIGNAGE BASIS OF DESIGN IS POBLOCKI SIGN COMPANY. SIGNAGE TYPES SHOWN ON A8-7 ARE FOR REFERENCE ONLY. TREATMENT CHAIR
TREATMENT AREA 2 2 9 WALL ABOVE COORESPONDING
3. SIGNAGE TO BE MOUNTED AS SHOWN ON A6-1, UNO. TREATMENT CHAIR
TREATMENT AREA 3 3 9 WALL ABOVE COORESPONDING
4. ALL SIGNAGE TO COMPLY WITH ACCESSIBLE GUIDELINES ANSI 117.1 FOR VISUAL CHARACTERS, RAISED CHARACTERS, BRAILLE TREATMENT CHAIR
AND INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY.
TREATMENT AREA 4 4 9 WALL ABOVE COORESPONDING
5. ALL ROOMS TO RECEIVE SIGNAGE WILL BE CONFIRMED IN SHOP DRAWINGS. TREATMENT CHAIR
TREATMENT AREA 5 5 9 WALL ABOVE COORESPONDING
6. PROVIDE SIGN NAME "RECEIVING" AT EXTERIOR DOOR 100D. TREATMENT CHAIR
TREATMENT AREA 6 6 9 WALL ABOVE COORESPONDING
7. PROVIDE OCCUPANCY CAPACITY SIGNS AT ALL WAITING AREAS AND CONFERENCE ROOMS. TREATMENT CHAIR Department of Capital Planning & Policy
TREATMENT AREA 7 7 9 WALL ABOVE COORESPONDING Bureau of Asset Management
8. PROVIDE (3) EVACUATION PLANS: ARCHITECT TO PROVIDE FLOOR PLAN GRAPHIC FOR THE EVACUATION PLANS. LOCATIONS TREATMENT CHAIR
SHALL BE CONFIRMED IN SHOP DRAWINGS. Notice: This drawing has not been published and is the
PRIVATE PAT./ISOLATION 8 ISOLATION ROOM 8 2 & 2.1 ADHERED TO GLASS WALL
sole property of Cook County. It is loaned to the borrower
TREATMENT AREA 9 9 9 WALL ABOVE COORESPONDING
TYPE 2.1: 9. PROVIDE SIGNAGE FOR FIRE DEPARTMENT CONNECTION LOCATION IN VESTIBULE.
TREATMENT CHAIR
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
INSERT PANEL WINDOW 10. SIGN TYPES ARE FOR REFERENCE ONLY. ALL SIGNAGE SHALL BE APPROVED BY THE OWNER. THE FINAL TEXT (ENGLISH & TREATMENT AREA 10 10 9 WALL ABOVE COORESPONDING return it upon request and agrees that it shall not be
SPANISH) SHOULD BE REVIEWED WITH THE OWNER PRIOR TO RELEASE FOR FABRICATION. TREATMENT CHAIR reproduced, copied, loaned, or otherwise disposed of
TREATMENT AREA 11 11 9 WALL ABOVE COORESPONDING directly or indirectly, nor used for any purpose other than
14. PERMANENT ROOM SIGNS ARE TO BE LOCATED AT DOORWAYS, U.N.O. TREATMENT CHAIR for which it is furnished, in whole or part.
TREATMENT AREA 12 12 9 WALL ABOVE COORESPONDING
15. SIGNS CAN MOUNT TO THE DOOR ITSELF IF:
TREATMENT CHAIR
A. THE SIGN IS MOUNTED ON THE PUSH SIDE OF THE DOOR (IT SWINGS INWARD).
B. THE DOOR AUTOMATICALLY CLOSES. VESTIBULE 100A -
C. THE DOOR HAS NO HOLD OPEN DEVICES. CORRIDOR 100B -
CORRIDOR 100C -
CORRIDOR 100D -
WAITING ROOM 101 OCCUPANCY CAPACITY
CONFERENCE 102 CONFERENCE ROOM 2 ADHERED TO GLASS WALL
DIETITIAN 103 DIETITIAN 2 PUSH SIDE OF DOOR
SOCIAL WORKER 104 SOCIAL WORKER 2 PUSH SIDE OF DOOR
RECEPTION 105 -
EXAM 106 EXAM ROOM 2 PUSH SIDE OF DOOR
WOMENS 107 WOMEN 6 PUSH SIDE OF DOOR
MENS 108 MEN 6 PUSH SIDE OF DOOR
OFFICE 109 OFFICE 2 PUSH SIDE OF DOOR
TYPE 3: TYPE 4: TYPE 5: TYPE 6: DIRECTOR OFFICE 110 DIRECTOR OFFICE 2 PUSH SIDE OF DOOR
SIGN W/ ROOM NAME & NUMBER LARGE SIGN W/ ROOM NAME & NUMBER TOILET ROOM SIGN TOILET ROOM SIGN TELECOM 111 TELECOM ROOM 2 PUSH SIDE OF DOOR
JANITOR'S CLOSET 112 JANITORS CLOSET 2 PUSH SIDE OF DOOR
STAFF 113 STAFF ROOM 2 PUSH SIDE OF DOOR
CHANGING ROOM 113A CHANGING ROOM 2 PUSH SIDE OF DOOR
STAFF TOILET 113B STAFF TOILET 6 PUSH SIDE OF DOOR
PAT. TOILET 114 PATIENT TOILET 5 PUSH SIDE OF DOOR
MED. PREP. 115 MEDICAL PREP 2 NEAREST ADJACENT WALL
TREATMENT AREA 116 TREATMENT AREA 4 NEAREST ADJACENT WALL @
CORRIDOR
NURSE STATION 116A -
W.C. 117A PATIENT TOILET 5 PUSH SIDE OF DOOR
SOILED STORAGE 118 SOILED STORAGE 2 PUSH SIDE OF DOOR
CLEAN SUPPLY 119 CLEAN SUPPLY 2 PUSH SIDE OF DOOR
EQUIP. REPAIR 120 EQUIPMENT REPAIR ROOM 2 PUSH SIDE OF DOOR
LAB 121 LAB 2 PUSH SIDE OF DOOR
STORAGE 122 STORAGE 2 PUSH SIDE OF DOOR
ELECTRICAL 123 ELECTRICAL ROOM 2 PUSH SIDE OF DOOR
MECHANICAL 124 MECHANICAL ROOM 2 PUSH SIDE OF DOOR
WATER TREATMENT 125 WATER TREATMENT ROOM 2 PUSH SIDE OF DOOR

Holabird & Root, LLC expressly disclaims any


responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.

Not published - All rights reserved.

TYPE 7:
REGULATORY/ADVISORY VINYL ON ENTRY GLASS

TYPE 8: TYPE 9:
TACTILE EXIT SIGN OPEN EXAM SIGN

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

BUILDING SIGNAGE

Sheet Name

Drawing No. A8-7


SUSPENDED GRID W/ REVEAL,
TYP.

CEILING SUSPENSION TIE ROD


TO UNDERSIDE OF SUPPORT
FRAME, TYP.
ACOUSTICAL CEILING TILE

CEILING
SEE RCP
CEILING SUSPENSION TIE ROD
1/2" ALUM SHADOW MOLDING TRIM TO UNDERSIDE OF SUPPORT
SUSPENDED GRID W/ REVEAL, FRAME
CEILING SUSPENSION TIE ROD 2" 5/8" GPDW ON 3 5/8" MTL STUD
TYP.
SUSPENDED GRID W/ REVEAL TO UNDERSIDE OF SUPPORT
LATERAL BRACING FRAME, TYP. CEILING SUSPENSION Department of Capital Planning & Policy

6" MIN.
ACOUSTICAL CEILING TILE
SUSPENDED GRID W/ REVEAL, TYP. SUSPENDED GRID W/ REVEAL, TYP. TIE ROD TO UNDERSIDE
Bureau of Asset Management

6" MIN
OF SUPPORT FRAME

6" MIN
FOR ELEVATIONS
CEILING Notice: This drawing has not been published and is the
SEE PLAN

SEE RCP SUSPENDED GRID W/ REVEAL sole property of Cook County. It is loaned to the borrower
CEILING RECESSED COVE
SEE RCP CEILING SUSPENSION TIE ROD CEILING
LIGHT. PROVIDE for their confidential use only. In consideration of the loan
TO UNDERSIDE OF SUPPORT FRAME SEE RCP ACOUSTICAL CEILING TILE of this drawing, the borrower promises and agrees to
ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE BLOCKING AS NEEDED.
1/2” DRYWALL TO ACOUSTICAL return it upon request and agrees that it shall not be

6"
1/2" ALUM SHADOW
1/2" ALUM SHADOW MOLDING TRIM CEILING SHADOW REVEAL MOLDING TRIM 1/2" ALUM SHADOW MOLDING TRIM
CEILING reproduced, copied, loaned, or otherwise disposed of
CEILING SEE RCP
SUSPENDED GRID W/ REVEAL directly or indirectly, nor used for any purpose other than
SEE RCP ALIGN SOFFIT FACE WITH WALL
ACOUSTICAL CEILING TILE
5/8" GPDW ON 3 5/8" for which it is furnished, in whole or part.
5/8" GPDW ON 3 5/8" MTL STUD MTL STUD 2' - 0"
ACOUSTICAL CEILING TILE DRYWALL CEILING

6" MIN.
5/8" GPDW ON 3 5/8" MTL STUD
1/2" ALUM SHADOW MOLDING TRIM RECESSED DOWNLIGHT
CEILING
SEE RCP CEILING
ALIGN SOFFIT FACE WITH WALL
SEE RCP
DRYWALL CEILING 1' - 10" ALIGN SOFFIT FACE CORRIDOR 100E DENTAL EXAM
WITH WALL

TREATMENT AREA NURSE'S STATION

1
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
2
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
3
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
4
A9-1
CEILING DETAIL - RECESSED COVE LIGHT
1 1/2" = 1'-0" [REF: 1/ A3-1]

SUSPENDED GRID W/
REVEAL, TYP.

CEILING SUSPENSION TIE ROD


TO UNDERSIDE OF SUPPORT
FRAME
6" MIN

CEILING
SEE RCP

ACOUSTICAL CEILING TILE

1/2" ALUM SHADOW


MOLDING TRIM SOFFIT DIFFUSER, SEE
MECHANICAL DRAWINGS
CEILING SUSPENSION
5/8" GPDW ON 3 5/8"
MTL STUD
TIE ROD TO UNDERSIDE
EXISTING STRUCTURE OF SUPPORT FRAME
CEILING SUSPENSION TIE ROD
TO UNDERSIDE OF SUPPORT FRAME CEILING
SEE RCP
RECESSED DOWNLIGHT EXISTING FASCIA

6"
LAY IN CEILING
Holabird & Root, LLC expressly disclaims any
WINDOW ROLLER SHADE
CEILING responsibility arising from any unauthorized use of these
SEE RCP
plans, drawings and notes. Any authorization must be in
CEILING
SEE RCP NEW GBDW SOFFIT ON 2 1/2" FRAMING writing.
EXISTING STOREFRONT
ALIGN SOFFIT FACE 1' - 6"
WITH WALL
This drawing copy may have been reproduced at a size
different than originally drawn. The Owner and Architect
DRYWALL CEILING assume no responsibility for use of incorrect scale.
1/2" ALUM SHADOW MOLDING TRIM Drawings are not to be scaled.

Not published - All rights reserved.

5
A9-1
CEILING DETAIL
1 1/2" = 1'-0"
6
A9-1
Section 4
1 1/2" = 1'-0" [REF: 1/ A3-1]

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

INTERIOR DETAILS

Sheet Name

Drawing No. A9-1


GENERAL NOTES: DEMOLITION PLANS
1. FIELD VERIFY ALL EXISTING CONDITIONS. SCOPE OF THE
DEMOLITION WORK SHALL BE AS SHOWN ON THE DRAWINGS
INCLUDING BUT NOT LIMITED TO THE FOLLOWING : PORTIONS OF
EXISTING WALLS, FLOOR AND WALL FINISHES, DOORS,
CEILINGS, LIGHTING, PLUMBING, DUCT WORK, EQUIP., CONDUIT,
CABLE TRAYS, WIRING AND SELECT FLOORING TO SUBSTRATE.
1 2 3 REMOVE ALL CASEWORK AND EQUIPMENT AND ALL MOUNTED
10" ACCESSORIES.

9" WOMENS MEN'S MEN'S 2. TO THE BEST OF ARCHITECT'S KNOWLEDGE, ALL ELEMENTS
PUBLIC TOILET PUBLIC TOILET STAFF TOILET IDENTIFIED FOR DEMOLITION ARE NON-LOAD BEARING. ALL
BEARING ELEMENTS ARE TO REMAIN UNLESS NOTED
OTHERWISE. CONTACT ARCHITECT IF THERE IS A CONCERN
A A OVER WHETHER AN ELEMENT IS LOAD BEARING OR NOT. DO
024119.02
WOMEN'S SUPERVISORS DIRECTOR NOT PROCEED UNTIL ARCHITECT EVALUATES ELEMENT IN Department of Capital Planning & Policy
STAFF LOUNGE STAFF TOILET 024119.02
AND LOCKERS
QUESTION. ALL BEARING ELEMENTS NOT TO BE REMOVED ARE Bureau of Asset Management
024119.09 TO BE PROTECTED.
024119.01 024119.02 Notice: This drawing has not been published and is the
3. ALL COLUMNS, BEAMS, FLOOR/CEILING JOISTS TO REMAIN, sole property of Cook County. It is loaned to the borrower
U.N.O. for their confidential use only. In consideration of the loan
024119.03 of this drawing, the borrower promises and agrees to
024119.15 024119.01 024119.01
VESTIBULE 024119.09 024119.08 024119.02
024119.06
024119.02 4. ALL WORK TO BE DONE IN ACCORDANCE WITH APPLICABLE return it upon request and agrees that it shall not be
024119.01 JANITOR'S reproduced, copied, loaned, or otherwise disposed of
024119.09 024119.03
BUILDING CODES AND ALL OTHER CODES THAT HAVE
024119.10 024119.02 CLOSET AUTHORITY OVER THIS PROJECT. SECURE REQUIRED PERMITS. directly or indirectly, nor used for any purpose other than
024119.06
PROVIDE ALL NECESSARY SAFEGUARDS, BARRIERS, for which it is furnished, in whole or part.
B B TEMPORARY POWER, LIGHTING, FIRE PROTECTION, ETC. AS
024119.03
024119.07 REQUIRED DURING DEMOLITION.
024119.15 024119.05 024119.06
5. COORDINATE NEW OPENINGS WITH MECH. LOCATIONS & SIZES.
024119.03
WAITING AREA REFER TO MECH. DOCUMENTS FOR ADDITIONAL OPENINGS.
024119.06 024119.02
024119.08 024119.05 STORAGE 6. CONTRACTOR SHALL EXERCISE CARE TO AVOID DAMAGE TO
024119.10 ENTRY EXISTING WORK, ADJACENT SURFACES AND ADJOINING AREAS
024119.01 INCLUDING BUT NOT LIMITED TO THE PORTION OF THE WORK
024119.02 PHARMACY THAT IS TO REMAIN AS PART OF THE COMPLETED
024119.04 CONSTRUCTION, CONTRACTOR SHALL BE REQUIRED TO REPAIR
024119.02
OR OTHERWISE RESTORE ANY SUCH AREAS OR SURFACES THAT
BECOME DAMAGED OR REMOVED ON ACCOUNT OF THE
C 024119.14 024119.03
C DEMOLITION WORK.
024119.06
7. DEMOLITION SHALL BE PERFORMED IN AN ORDERLY SEQUENCE
024119.10
024119.03 024119.02
SCHEDULED BY THE CONTRACTOR AND COORDINATED WITH
VESTIBULE 024119.06 THE OWNER.
024119.02 024119.01
024119.09 WAITING AREA 024119.08
8. CONTRACTOR SHALL BE REQUIRED TO LEGALLY DISPOSE OF
024119.14 024119.01 ANY SALVAGED ITEMS THAT OWNER DOES NOT REQUIRE.

024119.15 024119.02 PATIENT 024119.02 TELEPHONE ELECTRICAL MECHANICAL 9. THE ARCHITECT HAS NO KNOWLEDGE OF AND SHALL NOT BE
ADVOCATE ROOM ROOM ROOM HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDDOUS
024119.16
MATERIALS ON JOB SITE. THE CONTRACTOR SHALL
IMMEDIATELY ISOLATE THE AFFECTED IF ASBESTOS OR OTHER
D D HAZARDOUS MATERIALS ARE DISCOVERED DURING
CONSTRUCTION. NOTIFY OWNER FOR FURTHER INSTRUCTION
BEFORE PROCEEDING.

024119.18
10. COORDINATE/VERIFY WITH THE OWNER ALL FURNITURE &
1 2 3 CASEWORK TO BE SALVAGED PRIOR TO DEMOLITON.

11. SCHEDULE ALL SERVICE SHUT DOWNS WITH OWNER.

1 100 LEVEL DEMOLITION PLAN


DA2-1 1/8" = 1'-0"
12. THE ARCHITECTURAL DEMOLITION DRAWING INDICATES THE
CONSTRUCTION TO BE REMOVED, BUT NOT NECESSARILY THE
EXACT QUANTITY,, TYPE OF MATERIAL, OR EXTENT OF
DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
VISITING THE SITE, VERIFYING EXISTING CONDITIONS, AND
REFERRING TO ALL CONSTRUCTION DOCUMENTS FOR
SPECIFICS RELATED TO THESE ITEMS.

13. SEE PLUMBING DRAWINGS FOR EXTENT OF FLOOR TRENCHING


FOR NEW PLUMBING LINES.
Holabird & Root, LLC expressly disclaims any
14. SEE MEP DRAWINGS FOR EXTENT OF MEP DEMOLITION. responsibility arising from any unauthorized use of these
1 2 3 plans, drawings and notes. Any authorization must be in
15. CONTRACTOR SHALL ANTICIPATE AND MAKE ANY AND ALL writing.
ARRANGEMENT WITH LOCAL GOVERNMENT AGENCIES SHOULD
ENTRY ONTO OR OBSTRUCTION OF A PUBLIC WAY BE This drawing copy may have been reproduced at a size
NECESSARY IN CONNECTION WITH THE WORK. different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
16. PROVIDE AND MAINTAIN SHORING, BRACING, AND STRUCTURAL Drawings are not to be scaled.
A A SUPPORTS AS REQUIRED TO PRESERVE STABILITY AND
PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OR Not published - All rights reserved.
024119.11
CONSTRUCTION OR FINISHES THAT ARE TO REMAIN, PREVENT
024119.11 024119.11
024119.11 024119.11 024119.11 024119.11 UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF
024119.13 CONSTRUCTION BEING DEMOLISHED.
024119.12 024119.12 024119.11

024119.12
SYMBOLS: DEMOLITION PLANS
024119.13

024119.12 EXISTING WALL TO REMAIN

B B DEMO DOOR

DEMO WALL
024119.12 DEMO/TRENCH/EXCAVATE SLAB/ASPHALT AS
1 09/07/2018 ISSUED FOR BID
REQUIRED FOR SCOPE; DRAWING MAY NOT
024119.13 024119.11 SHOW ALL REQUIRED TRENCHING / No. Date Issue
EXCAVATION; COORDINATE EXTENT WITH
024119.12
ALL TRADES
Project Number 15849
024119.11 KEYNOTES: DEMOLITION PLANS
TUNNELING BELOW EXISTING SLAB Drawn S. DENNY
C C Key Value Keynote Text
024119.12 Checked K. BOYER

024119.13 024119.01 REMOVE HM FRAMES & WOOD DOORS Proj. Arch./Eng. K. SCHUSTER
024119.12 024119.02 REMOVE METAL STUD AND GBDW WALLS
024119.03 REMOVE STEEL SHUTTERS & ASSOCIATED
FRAMES & MOTORS
024119.04 REMOVE CMU FOR NEW DOOR
024119.05 REMOVE ACT FLOORING Provident Hospital - Renal
024119.11
024119.13 024119.06 REMOVE MILLWORK COUNTERTOPS Dialysis Center
024119.07 REMOVE DOOR & FRAME
024119.08 REMOVE FIXED SEATING
D D
024119.09 REMOVE VESTIBULE STOREFRONT
024119.10 REMOVE CONC & WOOD PLANTER/SEAT WALL
024119.11 REMOVE SUSPENDED ACT CEILING
024119.12 REMOVE GBDW SOFFIT
1 2 3 024119.13 REMOVE PLASTER CEILING
024119.14 REMOVE AND REPLACE ENTRY DOORS
024119.15 NEW DUCT WORK OPENINGS IN CMU

2 100 LEVEL DEMO REFLECTED CEILING PLAN


DA2-1 1/8" = 1'-0"
BULKHEAD. SEE MECHANICAL DRAWINGS. USE
EXISTING OPENINGS WHERE POSSIBLE.
PROVIDE NEW LINTELS WHERE NECESSARY.
430 East 51st Place
Chicago, Illinois 60615

024119.16 REMOVE DOOR WHILE LEAVING FRAME INTACT.


024119.18 REMOVE EXISTING BOLLARD IN CONFLICT WITH Project Name
NEW GENERATOR ENCLOSURE.
100 LEVEL DEMOLITION PLAN
AND REFLECTED CEILING
DEMOLITION PLAN
Sheet Name

Drawing No. DA2-1


GENERAL NOTES: DEMOLITION PLANS
1. FIELD VERIFY ALL EXISTING CONDITIONS. SCOPE OF THE
DEMOLITION WORK SHALL BE AS SHOWN ON THE DRAWINGS
INCLUDING BUT NOT LIMITED TO THE FOLLOWING : PORTIONS OF
EXISTING WALLS, FLOOR AND WALL FINISHES, DOORS,
CEILINGS, LIGHTING, PLUMBING, DUCT WORK, EQUIP., CONDUIT,
CABLE TRAYS, WIRING AND SELECT FLOORING TO SUBSTRATE.
REMOVE ALL CASEWORK AND EQUIPMENT AND ALL MOUNTED
ACCESSORIES.

2. TO THE BEST OF ARCHITECT'S KNOWLEDGE, ALL ELEMENTS


IDENTIFIED FOR DEMOLITION ARE NON-LOAD BEARING. ALL
BEARING ELEMENTS ARE TO REMAIN UNLESS NOTED
OTHERWISE. CONTACT ARCHITECT IF THERE IS A CONCERN
OVER WHETHER AN ELEMENT IS LOAD BEARING OR NOT. DO
NOT PROCEED UNTIL ARCHITECT EVALUATES ELEMENT IN Department of Capital Planning & Policy
QUESTION. ALL BEARING ELEMENTS NOT TO BE REMOVED ARE Bureau of Asset Management
TO BE PROTECTED.
Notice: This drawing has not been published and is the
3. ALL COLUMNS, BEAMS, FLOOR/CEILING JOISTS TO REMAIN, sole property of Cook County. It is loaned to the borrower
U.N.O. for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
4. ALL WORK TO BE DONE IN ACCORDANCE WITH APPLICABLE return it upon request and agrees that it shall not be
BUILDING CODES AND ALL OTHER CODES THAT HAVE reproduced, copied, loaned, or otherwise disposed of
AUTHORITY OVER THIS PROJECT. SECURE REQUIRED PERMITS. directly or indirectly, nor used for any purpose other than
1 2 3 PROVIDE ALL NECESSARY SAFEGUARDS, BARRIERS, for which it is furnished, in whole or part.
TEMPORARY POWER, LIGHTING, FIRE PROTECTION, ETC. AS
REQUIRED DURING DEMOLITION.

5. COORDINATE NEW OPENINGS WITH MECH. LOCATIONS & SIZES.


REFER TO MECH. DOCUMENTS FOR ADDITIONAL OPENINGS.
A A 6. CONTRACTOR SHALL EXERCISE CARE TO AVOID DAMAGE TO
EXISTING WORK, ADJACENT SURFACES AND ADJOINING AREAS
INCLUDING BUT NOT LIMITED TO THE PORTION OF THE WORK
THAT IS TO REMAIN AS PART OF THE COMPLETED
CONSTRUCTION, CONTRACTOR SHALL BE REQUIRED TO REPAIR
OR OTHERWISE RESTORE ANY SUCH AREAS OR SURFACES THAT
BECOME DAMAGED OR REMOVED ON ACCOUNT OF THE
DEMOLITION WORK.

7. DEMOLITION SHALL BE PERFORMED IN AN ORDERLY SEQUENCE


SCHEDULED BY THE CONTRACTOR AND COORDINATED WITH
THE OWNER.
B B
8. CONTRACTOR SHALL BE REQUIRED TO LEGALLY DISPOSE OF
ANY SALVAGED ITEMS THAT OWNER DOES NOT REQUIRE.

9. THE ARCHITECT HAS NO KNOWLEDGE OF AND SHALL NOT BE


HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDDOUS
MATERIALS ON JOB SITE. THE CONTRACTOR SHALL
IMMEDIATELY ISOLATE THE AFFECTED IF ASBESTOS OR OTHER
HAZARDOUS MATERIALS ARE DISCOVERED DURING
CONSTRUCTION. NOTIFY OWNER FOR FURTHER INSTRUCTION
BEFORE PROCEEDING.

10. COORDINATE/VERIFY WITH THE OWNER ALL FURNITURE &


C C CASEWORK TO BE SALVAGED PRIOR TO DEMOLITON.

11. SCHEDULE ALL SERVICE SHUT DOWNS WITH OWNER.

12. THE ARCHITECTURAL DEMOLITION DRAWING INDICATES THE


CONSTRUCTION TO BE REMOVED, BUT NOT NECESSARILY THE
EXACT QUANTITY,, TYPE OF MATERIAL, OR EXTENT OF
DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
VISITING THE SITE, VERIFYING EXISTING CONDITIONS, AND
REFERRING TO ALL CONSTRUCTION DOCUMENTS FOR
SPECIFICS RELATED TO THESE ITEMS.

13. SEE PLUMBING DRAWINGS FOR EXTENT OF FLOOR TRENCHING


D D FOR NEW PLUMBING LINES.
Holabird & Root, LLC expressly disclaims any
COORDINATE LOCATION OF 14. SEE MEP DRAWINGS FOR EXTENT OF MEP DEMOLITION. responsibility arising from any unauthorized use of these
SUBSLAB CONDUITS WITH plans, drawings and notes. Any authorization must be in
EXISTING MEP COMPONENTS 15. CONTRACTOR SHALL ANTICIPATE AND MAKE ANY AND ALL writing.
1 2 3 ARRANGEMENT WITH LOCAL GOVERNMENT AGENCIES SHOULD
ENTRY ONTO OR OBSTRUCTION OF A PUBLIC WAY BE This drawing copy may have been reproduced at a size
NECESSARY IN CONNECTION WITH THE WORK. different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
16. PROVIDE AND MAINTAIN SHORING, BRACING, AND STRUCTURAL Drawings are not to be scaled.
SUPPORTS AS REQUIRED TO PRESERVE STABILITY AND
1 100 LEVEL TRENCHING AND SELECTIVE DEMOLITION PLAN
DA2-2 1/8" = 1'-0"
PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OR
CONSTRUCTION OR FINISHES THAT ARE TO REMAIN, PREVENT
Not published - All rights reserved.
UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF
CONSTRUCTION BEING DEMOLISHED.

SYMBOLS: DEMOLITION PLANS


EXISTING WALL TO REMAIN

DEMO DOOR

DEMO WALL

DEMO/TRENCH/EXCAVATE SLAB/ASPHALT AS
1 09/07/2018 ISSUED FOR BID
REQUIRED FOR SCOPE; DRAWING MAY NOT
SHOW ALL REQUIRED TRENCHING / No. Date Issue
EXCAVATION; COORDINATE EXTENT WITH
ALL TRADES
Project Number 15849

TUNNELING BELOW EXISTING SLAB Drawn S. DENNY


SAWCUT WIDTH 4" CONCRETE SLAB
COORDINATE WITH EXISTING
Checked K. BOYER
AS REQUIRED
EXTERIOR SLAB
12"
Proj. Arch./Eng. K. SCHUSTER
#3 @ 24" O.C. EACH WAY - ROUGHEN SURFACE AND APPLY
DOWEL INTO EXISTING
MIN. LAP BONDING AGENT PRIOR TO KEYNOTES LEGEND
PLACING CONCRETE
REF#

Provident Hospital - Renal


SELF-EXPANDING BUTYL
Dialysis Center
STRIP WATERSTOP -
CONTINUOUS AT EACH SIDE

VAPOR RETARDER
4' - 0"

MAX

COMPACTED STRUCTURAL FILL.


NOTE: DO NOT LEAVE VOIDS
UNDER EDGE OF EXISTING
SLAB AT CUT.
NEW PIPING
PIPE BEDDING MATERIAL
(SEE PLUMBING DRAWINGS
AND SPECIFICATIONS) 430 East 51st Place
Chicago, Illinois 60615

Project Name

NOTE:
SAWCUT CONTROL JOINTS IN NEW CONCRETE AS REQUIRED. 100 LEVEL TRENCHING PLAN
ALIGN NEW CONTROL JOINTS WITH EXISTING CONTROL JOINTS.

2 UTILITY TRENCH - SIM. AT EXTERIOR


DA2-2 1" = 1'-0"
Sheet Name

Drawing No. DA2-2


Department of Capital Planning & Policy
Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

1 2 3

DIRECTOR JANITOR'S STAFF CHANGING


TELECOM
WOMENS MENS OFFICE OFFICE CLOSET TOILET ROOM STAFF

A
TV-01
CONFERENCE CAV-01
MICRO-01

REFU-01

CASU-03 SOILED
ELEC-01
CORRIDOR MOVS-01 CORRIDOR STORAGE
PAT. TOILET NARC-01 MED. PREP.
DEAE-01
CLEAN WATER
TV-02 TV-01
REUN-01 REUN-01 EW-01 SUPPLY TREATMENT
CORRIDOR
B
WAITING WHEE-01 DRDU-06
ROOM
DRCL-01
DI-01 EW-01
TV-02
DI-01 x 11
TAEP-01 TVAR-01
EW-02 EQUIP.
NURSE
TV-01 STATION REPAIR
EW-01
LAB Holabird & Root, LLC expressly disclaims any
EXAM BINS-01 DRCL-01
responsibility arising from any unauthorized use of these
SCHT-01
EW-02 C plans, drawings and notes. Any authorization must be in
COPM-01 SCI-01
REUN-01
writing.

STORAGE This drawing copy may have been reproduced at a size


RECEPTION different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
DRCL-02 Drawings are not to be scaled.
DI-01 TVAR-01
Not published - All rights reserved.

VESTIBULE

D
SOCIAL TREATMENT PRIVATE ELECTRICAL MECHANICAL
DIETITIAN
WORKER AREA PAT./ISOLATION

EQUIPMENT SCHEDULE
Type Mark Description Count

1 100 LEVEL EQUIPMENT PLAN


FFE2-1 1/8" = 1'-0"
BINS-01 BIN, SHREDDING, SECURE 1
CASU-03 CART, PROCEDURE, RESUSCITATION 1
CAV-01 AV CABINET 1 1 09/07/2018 ISSUED FOR BID
COPM-01 COPIER, PRINTER, MULTIFUNCTION 1
No. Date Issue
DEAE-01 DEFIBRILLATOR, AED 1
DI-01 DIALYSIS MACHINE 15
DRCL-01 DIALYSIS RECLINER - NIC 12 15849
Project Number
DRCL-02 DIALYSIS BARIATRIC RECLINER - NIC 1
DRDU-06 DRUG DISPENSING UNIT 1 Drawn S. DENNY
ELEC-01 ELECTROCARDIOGRAPH 1 Checked K. BOYER
EW-01 EYE WASH 3
Proj. Arch./Eng. K. SCHUSTER
EW-02 EYE WASH, DRENCH HOSE 2
MICRO-01 MICROWAVE 1
MOVS-01 MONITOR, VITAL SIGNS 1
NARC-01 CABINET, STORAGE, CLINICAL, NARCOTICS 1
REFU-01 REFRIGERATOR FREEZER, UPRIGHT 1
Provident Hospital - Renal
REUN-01 REFRIGERATOR, UNDERCOUNTER 3
SCHT-01 SCALE, HEIGHT 1 Dialysis Center
SCI-01 SCALE, INTEGRATED 1
TAEP-01 EXAM TABLE POWE 1
TV-01 WALL MOUNTED TV 3
TV-02 WALL MOUNTED MONITOR 2
TVAR-01 TV ARM, ARTICULATING 12
WHEE-01 WHEELCHAIR 1

430 East 51st Place


Chicago, Illinois 60615

*SEE Q SERIES FOR OWNER


Project Name
EQUIPMENT SCHEDULE REFERENCED
IN THESE PLANS
100 LEVEL EQUIPMENT PLAN

Sheet Name

Drawing No. FFE2-1


Department of Capital Planning & Policy
Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
for their confidential use only. In consideration of the loan
of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.

1 2 3
DIRECTOR STAFF
JANITOR'S CHANGING
OFFICE OFFICE I.T. TOILET STAFF
WOMENS MENS CLOSET ROOM
107 108 109 110 111 113B 113
75SF 83SF 62SF
112 50SF 113A 210SF
33SF 20SF
LEP3028L LEP3028R T−38 T−38
A

C−11

C−11
X

X
15121−P

15121−P
29M

29M
C−11

C−11
15121−P

15121−P
HCT

HCT
42x24 42x24
FB FB

72x15x15 LD

72x15x15 LD
36x36 36x36

66
72x30

72x30
C−8

72

72
C−1G

66
15121−P 15121−P

C−1G

30/4
8
C−
C−11 C−11

C−8
8
LEP3028R LEP3028L

C−3

C−
B
CONFERENCE

C−2B C−2B
1
2'-10 _ "
SOILED

30/4

HIGS6
4 2−HIGH

C−3
C−2B
102 LOCKERS
STORAGE

HIGS6
HIGS6
2'-11"
207SF
118

C−3

C−3
B
100SF

P 96

B
HT LH
CORRIDOR

C−3
PAT. TOILET CORRIDOR

42x 96
B

C−3
114 100C 100D CLEAN WATER

B
SUPPLY TREATMENT

C−3
CORRIDOR 40SF

B
C−3
B
3'-5" 100B 119 125
100SF 329SF

U4
C−14A
C−14A
C−14EC−14A C−14B
MED. PREP. B
base
1392−C
add base
1392−M 1392−C
add
1392−OBA 115
12

U4
88SF

628S−28M
WHEELCHAIR 80SF
EXAM

628S−28M
106 1 EQUIP.

U4
76SF BBF
REPAIR
108SF
1392−C 1392−M 1392−C
base add add base
C−14EC−14A C−14A
C−14A
120
C−14A

SINGLE
C−9 C−8 C−1G C−1G 11

C−1G
C−1G
C−14A
C−14A
C−14EC−14A 80SF 147SF
WAITING C−14A

628S−28M
base add base add
1392−C 1392−M 1392−C
NURSE
ROOM

628S−28M
2 STATION
101 76SF
C−1G C−1G
1392−
OB
LAB
121
ba
1392−E C−14seB C add
−14A BBF
10
C−14G

U5
80SF 63SF

628S−28M
30/2 30/2
628S−09M−750

628S−28M
3

U5
C−1G
76SF
STORAGE
RECEPTION

U5
105 122 Holabird & Root, LLC expressly disclaims any
9 114SF

628S−28M
71SF responsibility arising from any unauthorized use of these

628S−28M
82SF

U4
4
76SF plans, drawings and notes. Any authorization must be in
C−2 C−2 writing.
VESTIBULE 1G 6 7 8
FF

C− HIGS6 HIGS6

100A
F

3S
xB2B4

HF2
80SF 80SF 130SF This drawing copy may have been reproduced at a size
54
8
542

MP6628
MP

42x15x15 LL

EP2428R
EP2428L
EP
24 2

628S−28M
60 x 628S−28M 628S−28M

different than originally drawn. The Owner and Architect


8L

42

5
0
8
112

66x30
EP

628S−28M
FB

2'-10"
8R

assume no responsibility for use of incorrect scale.


MP
242

602
8
76SF
EP

HIG
S6
54x2442

42x15x15 LL

C−
Drawings are not to be scaled.
HIG
S6 2B
30/4

C−

D
BBF

2B

DIETITIAN Not published - All rights reserved.


SOCIAL TREATMENT PRIVATE W.C. ELECTRICAL MECHANICAL
103 WORKER 117A 123 124
89SF AREA PAT./ISOLATION
104 116 117
47SF 118SF 102SF
101SF

1 100 LEVEL FURNITURE PLAN - FOR REFERENCE ONLY


FFE2-2 1/8" = 1'-0"

1 09/07/2018 ISSUED FOR BID


No. Date Issue

Project Number 15849


Drawn Author

Checked Checker
Proj. Arch./Eng. Approver

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

100 LEVEL FURNISHINGS PLAN -

FOR REFERENCE ONLY FOR REFERENCE ONLY


Sheet Name

Drawing No. FFE2-2


PROVIDENT HOSPITAL - RENAL
DIALYSIS CENTER
430 EAST 51ST PLACE CHICAGO, IL 60615

FOR THE:
COOK COUNTY HEALTH & HOSPITALS SYSTEM
DEPARTMENT OF FACILITIES

UNDER:
BOARD OF DIRECTORS
OF THE COOK COUNTY HEALTH & HOSPITALS SYSTEM
ARCHITECT / STRUCTURAL ENGINEER
HOLABIRD & ROOT LLC ISSUED BY:
140 SOUTH DEARBORN STREET
SUITE 500
CHICAGO, IL 60603
OFFICE OF THE CHIEF PROCUREMENT OFFICER
312.357.1771 TEL
312.357.1909 FAX
SUPPLY CHAIN MANAGEMENT
www.holabird.com BUILDING CODE CERTIFICATION STATEMENT
ISSUE FOR BID 09/07/2018 "I CERTIFY THAT THESE DRAWINGS WERE PREPARED BY ME
OR UNDER MY DIRECT SUPERVISION AND CONTROL AND TO
MECHANICAL, ELECTRICAL, & THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH THE
PLUMING DESIGN ENGINEERS REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE."
MEPIS INC
36 SOUTH WABASH AVE
SUITE 310
CHICAGO, IL 60603
312.279.1185 TEL
BID DEPOSIT TO BE 1% OF TOTAL BID
https://www.mepisinc.com BIDS SHALL BE EXECUTED IN TRIPLICATE
ALL SIGNATURES SHALL BE SWORN TO BEFORE A NOTARY PUBLIC
ARCHITECT'S SIGNATURE
PROJECT

RENAL DIALYSIS CENTER : ISSUED FOR: ADDENDUM #1 SEPTEMBER 13, 2018


COOK COUNTY/PROVIDENT HOSPITAL
430 E. 50th Pl. CHICAGO, IL 60615 Department of Capital Planning & Policy
DRAWING INDEX * INDICATES SHEET WAS ISSUED WITH THIS REVISION Bureau of Asset Management
Notice: This drawing has not been published and is the
sole property of Cook County. It is loaned to the borrower
GENERAL INTERIORS for their confidential use only. In consideration of the loan
G0-0 COVER SHEET ID1-1 INTERIOR FINISH SCHEDULE * P0600 DETAILS of this drawing, the borrower promises and agrees to
return it upon request and agrees that it shall not be
* G1-1 GENERAL INFORMATION & DRAWING INDEX ID2-1 100 LEVEL INTERIOR FINISHES PLAN * PD101 LEVEL 01 - PLUMBING - DEMOLITION PLAN reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.
LIFE SAFETY FFE FIRE PROTECTION
LS1-1 CODE INFORMATION & LIFE SAFETY PLAN FFE2-1 100 LEVEL EQUIPMENT PLAN * F0001 SYMBOLS, ABBREVIATIONS, NOTES & DETAILS
FFE2-2 100 LEVEL FURNISHINGS PLAN - FOR REFERENCE ONLY
DEMOLITION * F0100 LEVEL 01 - FIRE PROTECTION PLAN
DA2-1 100 LEVEL DEMOLITION PLAN AND REFLECTED CEILING OWNER EQUIPMENT (FOR REFERENCE ONLY)
DEMOLITION PLAN Q1-1 OWNER EQUIPMENT SCHEDULE FD101 LEVEL 01 FIRE PROTECTION DEMOLITION
DA2-2 100 LEVEL TRENCHING PLAN
MECHANICAL ELECTRICAL
ARCHITECTURAL M0001 SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES E0001 NOTES, LEGENDS, SYMBOLS AND ABBREVIATIONS
A1-1 ARCHITECTURAL SYMBOLS & ABBREVIATIONS
M0101 LEVEL 01 - HVAC DUCTWORK PLAN * E0101 LEVEL 01 LIGHTING PLAN
A2-1 100 LEVEL FLOOR PLAN & DIMENSION PLAN M0102 ROOF - HVAC DUCTWORK PLAN
A2-3 ROOF PLAN * E0201 LEVEL 01 POWER PLAN
M0501 SCHEDULES
A3-1 100 LEVEL REFLECTED CEILING PLAN * E0301 LEVEL 01 SYSTEMS PLAN
M0601 CONTROL DIAGRAMS E0302 ROOF LEVEL
A4-1 BUILDING ELEVATIONS
A4-2 BUILDING SECTIONS M0701 DETAILS * E0401 ELECTRICAL ENLARGED PLANS

A6-1 TYPICAL PLANS, ELEVATIONS, & DETAILS MD101 LEVEL 01 - HVAC DEMOLITION PLAN * E0521 POWER RISER DIAGRAMS
A6-2 TOILET ROOMS MD102 ROOF - HVAC DEMO PLAN
* E0601 LIGHTING SCHEDULES
A7-1 PARTITION TYPES & DETAILS PLUMBING * E0621 POWER SCHEDULES
A7-2 DOOR SCHEDULE, BORROWED LIGHT SCHEDULE, * P0001 SYMBOLS, ABBREVIATIONS & GENERAL NOTES
ELEVATIONS, & DETAILS E0701 ELECTRICAL DETAILS
* P0100 LEVEL 01 - PLUMBING - STORM, SANITARY & VENT PLAN E0702 ELECTRICAL DETAILS
A8-1 INTERIOR ENLARGED PLANS * P0100U UNDERGROUND PLUMBING PLAN
A8-2 INTERIOR ELEVATIONS ED101 LEVEL 01 DEMOLITION PLAN
A8-3 INTERIOR ELEVATIONS * P0200 LEVEL 01 - PLUMBING - DOMESTIC WATER PLAN
A8-4 TYPICAL CASEWORK DETAILS
A8-5 TYPICAL CASEWORK DETAILS * P0400 SANITARY WASTE AND VENT RISER DIAGRAM
A8-6 CASEWORK DETAILS * P0401 DOMESTIC WATER AND TEMPERED WATER RISER
A8-7 BUILDING SIGNAGE DIAGRAM

A9-1 INTERIOR DETAILS * P0500 SCHEDULES


PROJECT LOCATION
AREA OF WORK
N
Holabird & Root, LLC expressly disclaims any
responsibility arising from any unauthorized use of these
plans, drawings and notes. Any authorization must be in
writing.

This drawing copy may have been reproduced at a size


different than originally drawn. The Owner and Architect
assume no responsibility for use of incorrect scale.
Drawings are not to be scaled.
ADD LANDSCAPING AT
REMOVED WALK TO Not published - All rights reserved.
MATCH EXISTING

RENAL DIALYSIS CENTER


430 E. 50TH PL.
W. 50th Place CHICAGO, IL 60615

2 09/13/2018 ADDENDUM #1
1 09/07/2018 ISSUED FOR BID
No. Date Issue
COORD. NEW
GENERATOR
LOCATION W/MEP Project Number 15849
EXISTING LANDSCAPE /
WALKS TO REMAIN - NEW FENCED Drawn S. DENNY
NO NEW WORK ENCLOSURE
Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER
PROJECT TEAM
EXISTING PARKING
LOT TO REMAIN -
NO NEW WORK
ARCHITECTURE & MECHANICAL, PLUMBING, Provident Hospital - Renal
STRUCTURAL ENGINEERING ELECTRICAL, & FIRE PROTECTION Dialysis Center
ENGINEERING

HOLABIRD & ROOT LLC MEPIS INC S. Vince


140 SOUTH DEARBORN 36 SOUTH WABASH AVE
nn es Ave. 430 East 51st Place
Chicago, Illinois 60615
SUITE 500 SUITE 310
CHICAGO, IL 60603 CHICAGO, IL 60603 Project Name

312.357.1771 TEL 312.279.1185 TEL


312.357.1909 FAX 312.279.1186 FAX GENERAL INFORMATION &
DRAWING INDEX
www.holabird.com https://www.mepisinc.com
1 Site Plan
Sheet Name

G1-1 1/16" = 1'-0"


Drawing No. G1-1
SYMBOLS: FINISHES INTERIOR FINISH SCHEDULE
THE NOTES BELOW APPLY TO ID SERIES SHEETS ACT - ACOUSTICAL CEILING TILE PFT - PORCELAIN FLOOR TILE RS - RESILIENT SHEET WS - WINDOW SHADES
ONLY. CODE: ACT1 CODE: PFT1 CODE: RS1 CODE: WS1
SPEC#: 09 51 23 SPEC#: SPEC#: 09 65 16 SPEC#: 12 24 13
1. INDICATES ROOM FINISH. REFER TO FINISH MFR: ARMSTRONG MFR: MIRAGE MFR: TBD MFR: SEE SPEC
SCHEDULE ON SHEET ID1-1 FOR FINISH PRODUCT: HEALTH ZONE ULTIMA 1902 PRODUCT: TRANSITION STYLE: TBD COLOR: TBD
INFORMATION. SIZE: 24"x24"x1" COLOR: MILANO TR05 COLOR: TBD NOTES: ALL ROOMS WHERE NOTED
GRID: SILHOUETTE 1/8" REVEAL, 24x24, WHITE SIZE: 12x24 NOTES: TBD
WALL P1 AC1
CEILING NOTES: GENERAL, TYP. NOTES: TOILET ROOMS & JANITOR CLOSETS
C1 WB1 CODE: RS2 WT - WALK-OFF MAT
FLOOR BASE SPEC#: 09 65 16 CODE: WT1
CG - CORNER GUARDS PL - PLASTIC LAMINATE MFR: TBD SPEC#: 12 48 13
2. INDICATES TRANSITION DETAIL OR FINISH
CODE: CG1 CODE: PL1 STYLE: TBD MFR: MILLIKEN Department of Capital Planning & Policy
SPEC#. 10 26 00 SPEC#: 06 41 16 COLOR: TBD PRODUCT: TERGO 11C
CHANGE. REFER TO SHEET ID1-1 FOR MFR: TBD MFR: ARPA NOTES: TBD SIZE: MODULAR GRID Bureau of Asset Management
FINISH DETAIL. COLOR: TBD COLOR: LARIX 4367 COLOR: GRAPHITE Notice: This drawing has not been published and is the
T1.1 FINISH: TBD FINISH: STANDARD NOTES: TBD sole property of Cook County. It is loaned to the borrower
NOTES: TBD NOTES: ALL VERTICAL CASEWORK & LOCKERS SS - SOLID SURFACE for their confidential use only. In consideration of the loan
CODE: SS1 of this drawing, the borrower promises and agrees to
3. INDICATES LOCATION OF ACCENT CODE: PL2 SPEC#: 12 36 61.16 return it upon request and agrees that it shall not be
MATERIAL. REFER TO SHEET ID1-1 FOR P - PAINT SPEC#: 06 41 16 MFR: CORIAN reproduced, copied, loaned, or otherwise disposed of
FINISH INFORMATION. FLOOR TO CEILING CODE: P1 MFR: WILSONART COLOR: GLACIER WHITE directly or indirectly, nor used for any purpose other than
U.N.O. SPEC#: 09 91 23 COLOR: LINEN MATTE D427-60 NOTES: ALL COUNTERTOPS for which it is furnished, in whole or part.
P5 MFR: BENJAMIN MOORE FINISH: MATTE
COLOR: OC-65 CHANTILLY LACE NOTES: TBD
FINISH: SATIN SV- SOLID VINYL
NOTES: GENERAL, TYP. CODE: SV1
GENERAL NOTES: FINISHES PWT - PORCELAIN WALL TILE SPEC#: 09 65 19
THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY. CODE: P2 CODE: PWT1 MFR: ARMSTRONG FLOORING
SPEC#: 09 91 23 SPEC#: 09 30 13 STYLE: STRIATIONS BBT
MFR: BENJAMIN MOORE MFR: MIRAGE COLOR: TWILIGHT
1. FINISHES INDICATED IN FINISH SCHEDULE ARE BASIS OF DESIGN. SEE COLOR: 2065-10 ADMIRAL BLUE PRODUCT: TRANSITION SIZE: 12x24
SPECIFICATIONS FOR PROJECT REQUIREMENTS. FINISH: SATIN COLOR: MILANO TR05 NOTES: TBD
NOTES: ACCENT COLOR SIZE: 12x24
2. ALL WALL FINISHES TO COMPLY OR SUPERCEDE CLASS I FIRE RATING. NOTES: TOILET ROOMS CODE: SV2
CODE: P4 SPEC#: 09 65 19
3. REFER TO A3 SERIES FOR CEILING PATTERNS. SPEC#: 09 91 23 CODE: PWT2 MFR: ARMSTRONG FLOORING
MFR: BENJAMIN MOORE SPEC#: 09 30 13 STYLE: STRIATIONS BBT
4. REFER TO A6 SERIES FOR RESTROOM ENLARGED PLANS AND COLOR: 2064-20 PATRIOT BLUE MFR: MIRAGE COLOR: ATMOSPHERE
ELEVATIONS. FINISH: SATIN PRODUCT: TRANSITION SIZE: 12X24
NOTES: ACCENT COLOR COLOR: FADE TR 04-05 NOTES: TBD
5. REFER TO A7 SERIES FOR ALL DOOR TYPES AND FINISHES. ALL PAINTED SIZE: 12x24
DOORS AND FRAMES TO HAVE SEMI-GLOSS FINISH. CODE: P5 NOTES: TBD
SPEC#: 09 91 23 WP-VINYL WALLCOVERING
6. REFER TO A8 SERIES FOR ALL ELEVATIONS AND INTERIOR DETAILS. MFR: BENJAMIN MOORE CODE: PWT3 CODE: WP1
COLOR: WHITE SPEC#: 09 30 13 SPEC#: 09 72 10
7. ALL UNFINISHED GPDW (NOT PTD. OR WITH WALLCOVERING) TO BE TAPED FINISH: FLAT MFR: MIRAGE MFR: INPRO
AND SANDED. NOTES: ALL CEILINGS PRODUCT: TRANSITION PRODUCT: RICCOCHET, PASSAGE
COLOR: TORINO TR04 COLOR: TBD
8. ALL PAINTED WALL TO HAVE SATIN PAINT FINISH. CODE: P6 SIZE: 12x24 NOTES: TREATMENT AREA
SPEC#: 09 91 23 NOTES: TBD
9. ALL PAINTED CEILINGS TO BE FLAT PAINT FINISH. MFR: BENJAMIN MOORE CODE: WP2
COLOR: TO MATCH ADJACENT WALL SPEC#: 09 72 10
10. ALL DOORS TO BE BIRCH RIFT CUT, UNO. FINISH: SEMI-GLOSS RB - RUBBER WALL BASE MFR: INPRO
NOTES: ALL DOORS & FRAMES CODE: RB1 PRODUCT: RICCOCHET, PASSAGE
SPEC#: 09 65 13 COLOR: TBD
MFR: ROOPE NOTES: TREATMENT AREA
PBT - PORCELAIN BASE TILE COLOR: 123 CHARCOAL
CODE: PBT1 STYLE: 4" COVE VINYL WALL BASE
SPEC#: NOTES: GENERAL, TYP.
KEYNOTES: FINISHES MFR: MIRAGE
THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY. PRODUCT: TRANSITION
COLOR: MILANO TR05
SIZE: 6x24
1 KEYNOTE #1 NOTES: TOILET ROOMS & JANITOR CLOSETS

2 KEYNOTE #2

GENERAL NOTES: THRESHOLDS Holabird & Root, LLC expressly disclaims any
1. ALL ALUMINUM THRESHOLDS TO BE FIRE RATED( FR ) & CONFORM TO RESILIENT FLOORING 2 responsibility arising from any unauthorized use of these
LOCAL BUILDING CODES. plans, drawings and notes. Any authorization must be in
THRESHOLD AT CENTER OF writing.
2. USE ALUMINUM THRESHOLD UNDER ALL RATED DOORS (UNLESS FLOOR IS TRANSITION AT CENTER
DOOR
EXPOSED CONCRETE.) OF DOOR
This drawing copy may have been reproduced at a size
ALUMINUM SADDLE VINYL TRANSITION different than originally drawn. The Owner and Architect
DOOR
5/8" UNDERCUT @ DOOR U.N.O.

5/8" UNDERCUT @ DOOR U.N.O.


3. ALL ALUMINUM THRESHOLDS TO BE ANCHORED TO CONCRETE WITH FLAT THRESHOLD (NGP #410) WITH (JOHNSONITE assume no responsibility for use of incorrect scale.
HEAD METAL (FINISH TO MATCH ALUMINUM) EXPANSION ANCHORS. EXPANSION ANCHOR, SHIM AS #CTA-XX-N) ADHERED TO Drawings are not to be scaled.
5/8" UNDERCUT @ DOOR U.N.O.

REQUIRED. CONCRETE
4. RESILIENT = LVT OR SHEET VINYL FLOORING RESILIENT FLOORING 1 Not published - All rights reserved.
RESILIENT FLOORING 1

1/8"
1/8"
1/8"

1/8"
5. CARPET = CARPET OR CARPET TILE

1/8"
6. TILE = PORCELAIN OR CERAMIC TILE
CONCRETE
7. EPOXY = POURED EPOXY OR URETHANE FLOORING CONCRETE CONCRETE

8. DOOR TYPE AND THRESHOLD DIMENSIONS WILL VARY. SEE DOOR RESILIENT FLOOR RESILIENT FLOORING 2
SCHEDULE.

9. PROVIDE LATEX UNDER CARPET TO MAKE CARPET FIT TIGHTLY UNDER


DIVIDER STRIP AS NECESSARY.

T1.0 NO THRESHOLD T1.1 SILL W/ METAL THRESHOLD T1.2 SILL W/ VINYL THRESHOLD
RESILIENT RESILIENT RESILIENT RESILIENT RESILIENT RESILIENT

1 09/07/2018 ISSUED FOR BID


TRANSITION COLORS No. Date Issue
TX.0 - NO THRESHOLD
TX.1 - ALUMINUM WITH CLEAR COAT
TX.2 - VINYL - JOHNSONITE, COLOR TBD RESILIENT FLOORING
Project Number 15849
TRANSITION AT CENTER RESILIENT FLOORING Drawn S. DENNY
OF DOOR
VINYL WHEELED TRAFFIC DOOR Checked K. BOYER
1" UNDERCUT @ DOOR U.N.O.

TRANSITION
5/8" UNDERCUT @ DOOR U.N.O.

Proj. Arch./Eng. K. SCHUSTER


(JOHNSONITE VINYL TRANSITION
#CTA-XX-K)
TILE
1/8"
1/8"

Provident Hospital - Renal


3/8"
3/8"

WALK-OFF MAT Dialysis Center


SEALANT TO MATCH ALUMINUM TRACK BASE
TILE GROUT COLOR (JOHNSONITE #MT-00-A)
CONCRETE

T2.2 SILL W/ VINYL THRESHOLD T3.2 SILL W/ VINYL THRESHOLD


RESILIENT TILE RESILIENT WALK-OFF MAT

430 East 51st Place


Chicago, Illinois 60615

Project Name

INTERIOR FINISH SCHEDULE

Sheet Name

Drawing No. ID1-1


SYMBOLS: FINISHES
THE NOTES BELOW APPLY TO ID SERIES SHEETS
ONLY.

1. INDICATES ROOM FINISH. REFER TO FINISH


SCHEDULE ON SHEET ID1-1 FOR FINISH
INFORMATION.
WALL P1 AC1
CEILING
C1 WB1
FLOOR BASE

2. INDICATES TRANSITION DETAIL OR FINISH


CHANGE. REFER TO SHEET ID1-1 FOR
FINISH DETAIL.
Department of Capital Planning & Policy
T1.1
Bureau of Asset Management
3. INDICATES LOCATION OF ACCENT Notice: This drawing has not been published and is the
MATERIAL. REFER TO SHEET ID1-1 FOR sole property of Cook County. It is loaned to the borrower
FINISH INFORMATION. FLOOR TO CEILING for their confidential use only. In consideration of the loan
U.N.O. of this drawing, the borrower promises and agrees to
P5 return it upon request and agrees that it shall not be
reproduced, copied, loaned, or otherwise disposed of
directly or indirectly, nor used for any purpose other than
for which it is furnished, in whole or part.
GENERAL NOTES: FINISHES
THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY.

1. FINISHES INDICATED IN FINISH SCHEDULE ARE BASIS OF DESIGN. SEE


SPECIFICATIONS FOR PROJECT REQUIREMENTS.

2. ALL WALL FINISHES TO COMPLY OR SUPERCEDE CLASS I FIRE RATING.

3. REFER TO A3 SERIES FOR CEILING PATTERNS.

4. REFER TO A6 SERIES FOR RESTROOM ENLARGED PLANS AND


ELEVATIONS.

5. REFER TO A7 SERIES FOR ALL DOOR TYPES AND FINISHES. ALL PAINTED
DOORS AND FRAMES TO HAVE SEMI-GLOSS FINISH.
EXIST ACT1 EXIST ACT1 P1 ACT1 P1 ACT1 P1 N.G. P1 ACT1 P1 ACT1
EXIST EXIST EXIST EXIST SV2 RB2 SV2 RB2 SV2 RB1 PFT1 PBT1 PFT1 PBT1 6. REFER TO A8 SERIES FOR ALL ELEVATIONS AND INTERIOR DETAILS.

7. ALL UNFINISHED GPDW (NOT PTD. OR WITH WALLCOVERING) TO BE TAPED


A AND SANDED.

T2.2
P1 ACT1 8. ALL PAINTED WALL TO HAVE SATIN PAINT FINISH.
SV1 RB2
9. ALL PAINTED CEILINGS TO BE FLAT PAINT FINISH.
T1.0
10. ALL DOORS TO BE BIRCH RIFT CUT, UNO.
T1.0 P1 ACT 1 T1.0 T1.2 P1 ACT1 T1.2 T1.2 T2.2 T1.2
T1.0 P1 ACT1 11. EXIST ROOM FINISH IS EXISTING TO REMAIN, CLEAN.
SV1 RB2 CG1
RS1 RB2 CG1 CG1 RS1 RB2
P1 ACT1 CG1 P1 ACT1
CG1
SV1 RB1 SV1 RB2
T1.2 T1.2
P1 ACT1
T2.2
B KEYNOTES: FINISHES
CG1 P1 ACT1 P1 ACT1 P1 ACT1
P2 PFT1 PBT1 THE NOTES BELOW APPLY TO ID SERIES SHEETS ONLY.
RS1 RB2 RS2 RB1 RS2 RB1
CG1 T1.2
P1 ACT1 1 KEYNOTE #1
P1 ACT1
RS2 RB1
P1 ACT1 SV2 RB2 T1.2 P1 - 2 KEYNOTE #2
SV1 RB2 SC RB2
P1 ACT1
P1 ACT1 RS2 RB2
P3 T1.2
RS2 RB1

C Holabird & Root, LLC expressly disclaims any


P1 ACT1 responsibility arising from any unauthorized use of these
P3 P1 ACT1 T1.2
SV1 RB2 plans, drawings and notes. Any authorization must be in
P1 P5 SV2 RB2 CG1 writing.
CG1 CG1
WT1 RB2 T1.2 T1.2 P1 ACT1 P1 ACT1
T1.0 T1.2 This drawing copy may have been reproduced at a size
RS1 RB1 RS2 RB2
different than originally drawn. The Owner and Architect
T1.2 assume no responsibility for use of incorrect scale.
P1 ACT1 Drawings are not to be scaled.
P1 ACT1 T2.2
RS2 RB1
RS2 RB1
Not published - All rights reserved.

D
P1 ACT1
SV2 RB2 P1 ACT1 P1 ACT1
SV2 RB2 PFT1 PBT1

1 2 3

1 09/07/2018 ISSUED FOR BID


1
ID2-1
100 LEVEL FINISH PLAN
1/8" = 1'-0"
No. Date Issue

Project Number 15849


Drawn A. BAHENA

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER

Provident Hospital - Renal


Dialysis Center

430 East 51st Place


Chicago, Illinois 60615

Project Name

100 LEVEL INTERIOR FINISHES


PLAN
Sheet Name

Drawing No. ID2-1


SYMBOLS: LIFE SAFETY PLUMBING FIXTURES - TABULATION PER IPC 2004 SECTION 890.810 & APPENDIX A.TABLE B
CODE INFORMATION SF PER PERSON OCCUPANT LOAD OCCUPANT LOAD OCCUPANT LOAD
OCCUPANCY TYPE (IPC) (IPC) BUILDING TYPE (IPC) AREA (TOTAL) (MALE) (FEMALE)
PROJECT- RENOVATED INTERIOR SPACE IN AN EXISTING BUILDING
XX SPACE OCCUPANCY COUNT
Storage/Shipping Area 400 SF Office Buildings / Public 548 SF 1.369428 0.684714 0.684714
XXXXXXX SPACE FUNCTION
APPLICABLE CODES Buildings
Office Buildings 200 SF Office Buildings / Public 3423 SF 17.114801 8.557401 8.557401
THESE PLANS & SPECIFICATIONS HAVE BEEN PREPARED IN ACCORDANCE WITH THE Buildings
### OCCUPANT LOAD AT
Assembly Places - Facilities for 50 SF Office Buildings / Public 395 SF 7.898762 3.949381 3.949381
FOLLOWING BUILDING CODES & REGULATIONS. EGRESS DOOR Spectator Events; Worship Places and Buildings
2017 THE CITY OF CHICAGO BUILDING CODE Funeral Homes
4366 SF 26.382992 13.191496 13.191496
2012 NFPA101 EGRESS PATH
MINIMUM PLUMBING FIXTURES (IPC SECTION 890.APPENDIX A.TABLE B)
2015 INTERNATIONAL ENERGY CONSERVATION CODE
OFFICE (18 P) ASSEMBLY (8 P)
DEAD END CORRIDOR
REFERENCE BASIC BUILDING INFORMATION REMARKS MALE FEMALE MALE FEMALE
OCCUPANT LOAD 9 9 4 4
DIVISION 3 USE & OCCUPANCY CLASSIFICATION
1 HR RATED WALL
OFFICE - REQUIRED ASSEMBLY - REQUIRED TOTAL - REQUIRED ACTUAL
Department of Capital Planning & Policy
PLUMBING FIXTURE MALE FEMALE MALE FEMALE MALE FEMALE MALE FEMALE UNISEX Bureau of Asset Management
2 HR RATED WALL
13-56-120 CLASS F - BUSINESS WATER CLOSET 1 1 1 1 2 2 2 3 3 Notice: This drawing has not been published and is the
13-56-300 TRANSACTION OF BUSINESS FOR THE RENDERING OF PROFESSIONAL SERVICES - RENAL DIALYSIS AND WAITING AREA sole property of Cook County. It is loaned to the borrower
URINAL 50% - 50% - 50% - 1 - -
RENAL DIALYSIS EXISTING 2 HR RATED WALL for their confidential use only. In consideration of the loan
13-56-320 OCCUPANCY CONTENT : 100 SF PER PERSON - DIALYSIS CENTER LAVATORIES 1 1 1 1 2 2 2 2 3
300 SF PER PERSON - STORAGE ROOMS of this drawing, the borrower promises and agrees to
DRINKING FOUNTAINS 1 1 1 2
return it upon request and agrees that it shall not be
SERVICE SINK 1 PER FLOOR 1 PER FLOOR 1 PER FLOOR 1 PER FLOOR reproduced, copied, loaned, or otherwise disposed of
13-56-250 AUXILIARY USE: SPACES INCIDENTAL TO PRINCIPAL USE - ASSEMBLY & STORAGE WAITING AREA ASSEMBLY <100 directly or indirectly, nor used for any purpose other than
EGRESS - OCCUPANCY - TABULATION PER CBC, 2017
- SHALL COMPLY WITH SPECIFIC REQUIREMENTS OF THE USE PEOPLE IS CLASSIFIED AS THE SAME for which it is furnished, in whole or part.
- LIMITED TO 5% OF BUILDING AREA BUILDING OCCUPANCY OCCUPANCY (CBC 2017) AREA SF / OCCUPANT OCCUPANCY
- SPECIAL SEPARATION UNDER 13-56-280 NOT REQUIRED
Accessory storage areas, mechanical equipment 987 SF 300 9
room
DIVISION 4 SPECIAL REQUIREMENTS ON USE & OCCUPANCY Assembly - Without fixed seating - Concentrated 395 SF
(chairs only)
7 57

CHAPTER NOT APPLICABLE TO BUILDING SINCE NOT A HIGH RISE OR ATRIUM. Business areas 3009 SF 100 38
4391 SF 104

DIVISION 5 GENERAL BUILDING HEIGHT & AREA LIMITATIONS OCCUPANCY COUNT (EGRESS)

PROVIDENT RENAL DIALYSIS - EXISTING TYPE II NON-COMBUSTIBLE CONSTRUCTION NO CHANGE TO EXISTING BUILDING LEVEL 100 ANCILLARY: 9P
HEIGHT OR AREA ASSEMBLY: 57 P
TABLE 13-48 BLDG FLOOR TO # OF BUILDING BUSINESS: 38 P
104 P
FLOOR PROJECT AREA AREA FLOOR HEIGHT STORIES HEIGHT
100 LEVEL 6600 SF 6600 SF - 1 STORY 20'

HEIGHT:
BUILDING = SEE TABLE ABOVE (HEIGHT COMPLIES -
EXISTING (NO CHANGE)
AREA:
BUILDING = SEE TABLE ABOVE (AREA NOT LIMITED - AREA COMPLIES -
EXISTING (NO CHANGE)

DIVISION 6 TYPES OF CONSTRUCTION: TYPE II NON-COMBUSTIBLE CONSTRUCTION 2


A4-2
MAX. CAPACITY @ MAX. CAPACITY @
TYPE II NON-COMBUSTIBLE CONSTRUCTION (EXISTING BUILDING) EXIT DOOR
EXIT DOOR
135P @ 40" DOOR 135P @ 40" DOOR
TYPE II, NON-COMBUSTIBLE CONSTRUCTION, SHALL BE THAT CONSTRUCTION
IN WHICH ALL STRUCTURAL ELEMENTS, INCLUDING WALLS, BEARING
PARTITIONS, FLOORS, CEILINGS, ROOFS AND THEIR SUPPORTS, ARE OF NON-
COMBUSTIBLE MATERIALS BUT WHICH ARE GENERALLY NOT FIRE PROTECTED 1 STAFF
WOMENS MENS TOILET 3
EXCEPT AS REQUIRED IN SECTION 13-60-100. FIRE RETARDENT TREATED WOOD 1 1 I.T.
MA BE USED IN ROOF FRAMING AND ROOF SHEATHING OF ONE STORY BUS.
BUS. BUS.
BUILDINGS ONLY. 1 1 52
J.C. BUS.

DIVISION 7 FIRE-RESISTANCE-RATED CONSTRUCTION 3


BUS.
52 WATER
SUPPORTING MEMBERS - FIRE RESISTANT VALUES TREATMENT
RATING OF ANY STRUCTURAL MEMBER SHALL NOT BE LESS THAN THE REQUIRED 125
RATING OF CONSTRUCTION SUPPORTED BY SUCH MEMBER. PAT. TOILET 44" REQ.
1 1 1 58" PROV.
FIRE WALLS BUS. Holabird & Root, LLC expressly disclaims any
STORAGE STORAGE
RATING U.L. ASSEMBLY NUMBER responsibility arising from any unauthorized use of these
1- HOUR U465 plans, drawings and notes. Any authorization must be in
1 - HOUR/SMOKE U465 57 2 writing.
2 - HOUR U411 ASSEMBLY 2 WATER
1 TREATMENT This drawing copy may have been reproduced at a size
BUS.
A4-2 2 2 different than originally drawn. The Owner and Architect
THROUGH PENETRATION AND FIRE STOP SYSTEM BUS. assume no responsibility for use of incorrect scale.
BUS.
TYPE RATING U.L. ASSEMBLY NUMBER Drawings are not to be scaled.
WALL PENETRATION 1,2 &4 HR SYSTEM 550, 282, 284 Not published - All rights reserved.
CURTAIN WALL/SLAB 2 HR J900 SERIES 1
52 1
FLOOR PENETRATION 1,2 & 4 HR SYSTEM 429, 284
MAX. CAPACITY @ BUS. BUS.
1
EXIT DOOR MAX. CAPACITY @
FIRE ALARM SYSTEM 135P @ 40" DOOR STORAGE EXIT DOOR
DIRECT FIRE DEPARTMENT CONNECTION 135P @ 40" DOOR
52
CODED 15
52
BUS. W.C.
EMERGENCY POWER 1 2 1 1
BUS. 2
GENERATING SET BUS. ELEC. MECH.
BUS.
FOUR SOURCE COMED FEED

CHAPTER 8 INTERIOR FINISHES


CLASS FRAME SPREAD INDEX SMOKE DEVELOPED INDEX SEE TABLE 1018.1 FOR CORRIDOR DEAD END CORRIDOR TD=127' TD=135' DEAD END CORRIDOR 1 09/07/2018 ISSUED FOR BID
CLASS A 0- 25 0 - 400 WALLS DISTANCE = 9' - 9" DISTANCE = 9' - 6"
No. Date Issue
CLASS B 26-75 0 - 450
CLASS C 76-200 0 - 450

INTERIOR FINISH REQUIREMENTS BASED ON GROUP GROUP B ASSEMBLY: A3 REQUIREMENTS FOR BUILDING Project Number 15849
VERTICAL EXITS & EXIT PASSAGEWAYS
EXIT SCCESS CORRIDORS & OTHER TAXIWAYS
ROOMS & ENCLOSED SPACES
B
B
C
B
THAT IS FULLY SPRINKLER
1 100 LEVEL LIFE SAFETY PLAN
LS1-1 1/8" = 1'-0"
Drawn S. DENNY

Checked K. BOYER
Proj. Arch./Eng. K. SCHUSTER
CHAPTER 9 FIRE PROTECTION SYSTEMS
AUTOMATIC SPRINKLER SYSTEMS: TO COMPLY W/THIS SECTION BUILDING HAS AN AUTOMATIC
SPRINKLER SYSTEM - FULL
Provident Hospital - Renal
CHAPTER 10 MEANS OF EGRESS
Dialysis Center
TRAVEL DISTANCES: 127' DIALYSIS STATION 7 TO EXIT SEE 1/LS1-1
135' PRIVATE PATIENT TOILET TO EXIT

CODE ALLOWABLE TRAVEL DISTANCE: 225'


150' FOR BUSINESS USE PER 13-160-140,
PLUS 50%*150'=75' FOR AUTOMATIC SPRINKLER SYSTEM PER 13-160-150(a)

CHAPTER 13 EXIT REQUIREMENTS


430 East 51st Place
ACTUAL CAPACITY OF 40" DOOR = 1.5 UNITS SEE 1/LS1-1 Chicago, Illinois 60615
EXITS: 1.5 UNITS = 90 P/UW AT DOOR
PLUS 50%*90=135 FOR AUTOMATIC SPRINKLER SYSTEM
PER 13-160-150(a) Project Name

REQUIRED CAPACITY OCCUPANCY COUNT = 104 P / 2


OF EXITS: 52 P PER EACH EXIT PATH
CODE INFORMATION & LIFE
SAFETY PLAN
MINIMUM WIDTH OF 36" DOOR = 1.5 UNITS
EXITS: 1 UNIT = 60 P/UW AT DOORS Sheet Name

SWING OF EXIT DOORS: DIRECTION OF TRAVEL


Drawing No. LS1-1
Plan Room Name Room WHO WHO INSTALLS TYPE OF WHO INSTALLS
Item Manufacturer Model Catalog # Qty Ext Qty Accessories Per Each Location Arch Eq # Width (in.) Depth (in.) Height (in.) Weight (lb.) Volts Hertz Amps Description
Count PURCHASES INFRASTRUCTURE INFRASTRUCTURE EQUIPMENT

TREATMENT DIALYSIS MACHINES Fresnius Medical Care North America 2008T 12.0000 1.0000 12.0000 FLOOR DI-01 21.2500 24.8000 58.7000 198.4000 115.00 60.00 12.50 OWNER CONTRACTOR CONDUIT, CABLES, OWNER
DIALYSIS BOX, RO
WATER PIPNG
TREATMENT DIALYSIS RECLINER IOA SUSPEND 12.0000 1.0000 12.0000 FOLD DOWN ARM PANEL, FLOOR DRCL-01 OWNER HENRIKSEN
SOFT GRIP PUSH BAR
TREATMENT DIALYSIS BARIATRIC IOA SUSPEND 1.0000 1.0000 1.0000 FOLD DOWN ARM PANEL, FLOOR DRCL-02 OWNER HENRIKSEN
RECLINER SOFT GRIP PUSH BAR
TREATMENT SCALE, INTEGRATED Welch Allyn ScaleTronix 6102 1.0000 1.0000 1.0000 SCI-01 115.00 60.00 4.10 INTEGRATED SCALE RECESSED IN FLOOR, 825 LB CAPACITY, DIGITAL OWNER CONTRACTOR CONDUIT CONTRACTOR
LED DIPLAY
TREATMENT SCALE, HEIGHT SECCA 222.0000 1.0000 1.0000 1.0000 SCHT-01 12.1000 11.3000 91.3000 MEASURING ROD WITH LARGE MEASURING RANGE

TREATMENT WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 12.0000 1.0000 12.0000 FLOOR WACB-01 12.0000 12.0000 17.0000 18.0000 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
TREATMENT GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 4.0000 1.0000 4.0000 WALL GLBH-01 15.9500 3.9500 10.1000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
TREATMENT CONTAINER, SHARPS DANIELS SHARPSMART INC S22 1001207500 4.0000 1.0000 4.0000 1 ea. WALL BRACKET WALL COSH-01 15.5000 8.2500 17.3000 REUSABLE SHARPS CONTAINER WITH 16 QUART CAPACITY FOR USE OWNER CONTRACTOR BLOCKING CONTRACTOR
IN MODERATE VOLUME AREAS
TREATMENT MOBILE TECHNOLOGY TBD TBD 4.0000 1.0000 4.0000 CPTM-01
CART
TREATMENT TABLE, BEDSIDE STRYKER TRU-FIT 4.0000 1.0000 4.0000 FLOOR TBLB-01 17.5000 31.0000 43.0000 OVERBED TABLE, SINGLE TOP WITHOUT VANITY OWNER NA N/A HENRIKSEN
27-43.75
TREATMENT Waste Can, 08-19 Rubbermaid Commercial 2955 Small 12.0000 1.0000 12.0000 FLOOR WARE-02
Gallon Products Deskside (Beige)
TREATMENT

TREATMENT
TV Arm, Articulating

TV, PATIENT
TBD

TBD
TBD

TBD
12.0000

12.0000
1.0000

1.0000
12.0000

12.0000
CTRTOP TVAR-01

TV-03
Deck mounted articulating monitor arm

Patient TV
OWNER

OWNER
CONTRACTOR

CONTRACTOR
BLOCKING

N/A
CONTRACTOR

OWNER
Department of Capital Planning & Policy
NURSE STATION
ENGAGEMENT

Label Printer Brother International Corporation PT90 2.0000 1.0000 2.0000 PLBL-01
Bureau of Asset Management
NURSE STATION PC COMPUTER WITH TBD TBD TBD 4.0000 1.0000 4.0000 CTRTOP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE Notice: This drawing has not been published and is the
AND MOUSE
NURSE STATION WALL MTD MONITOR TBD TBD WALL TV-2 OWNER CONTRACTOR CONDUIT, CABLES, CONTRACTOR sole property of Cook County. It is loaned to the borrower
BRACKET FACE PLATE
for their confidential use only. In consideration of the loan
EXAM ROOM? Sphygmomanometer,
Aneroid, Mobile
Welch Allyn Inc 767 Mobile w/Weighted
Base & Adult cuff
1.0000 1.0000 1.0000
of this drawing, the borrower promises and agrees to
EXAM ROOM CONTAINER, SHARPS DANIELS SHARPSMART INC S22 1001207500 1.0000 1.0000 1.0000 1 ea. WALL BRACKET WALL COSH-01 15.5000 8.2500 17.3000 REUSABLE SHARPS CONTAINER WITH 16 QUART CAPACITY FOR USE
IN MODERATE VOLUME AREAS
OWNER CONTRACTOR BLOCKING CONTRACTOR
return it upon request and agrees that it shall not be
EXAM ROOM DIAGNOSTIC SET WELCH ALLYN 77791-MX 1.0000 1.0000 1.0000 WALL DISE-01 34.0000 6.0000 12.0000 115.0000 60.0000 1.0000 GREEN SERIES INTEGRATED WALL SYSTEM; INCLUDES WALL
BOARD, G777 WALL TRANSFORMER; 11720 COAXIAL
OWNER CONTRACTOR BLOCKING, CONDUIT CONTRACTOR
reproduced, copied, loaned, or otherwise disposed of
OPHTHALMOSCOPE, 23810 DIAGNOSTIC MACROVIEW OTOSCOPE,
52400-PF SPECULA DISPENSER, 7670-01 WALL ANEROID, 01690-300
SURETEMP PLUS THERMOMETER
directly or indirectly, nor used for any purpose other than
EXAM ROOM GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 1.0000 1.0000 1.0000 WALL GLBH-01 15.9500 3.9500 10.1000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR for which it is furnished, in whole or part.
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
EXAM ROOM STOOL, WITH BACK MIDMARK CORPORATION 277 1.0000 1.0000 1.0000 1 ea. BACKREST (9A366001) FLOOR STWB-01 21.5000 21.5000 35.0000 UPHOLSTERED, PNEUMATIC ADJUSTABLE STOOL WITH BACK; OWNER N/A N/A OWNER
ADJUSTS SEAT HEIGHT OF 18" TO 24.5"; ON 5-STAR CASTER BASE
WITH 3.25" CUSHIONED SEAT; 225 LB. CAPACITY.
EXAM ROOM LIGHT, EXAM/ WELCH ALLYN GS300 44400 1.0000 1.0000 1.0000 FLOOR LIET-01 20.8700 20.8700 58.6600 12.7500 120.0000 60.0000 0.3500 LED EXAM LIGHT ON MOBILE STAND; TOUCHLESS ON/OFF; 20,000 LUX OWNER CONTRACTOR CONDUIT OWNER
TREATMENT
EXAM ROOM TABLE, EXAM, POWER MIDMARK CORPORATION 223 1.0000 1.0000 1.0000 1 ea. LIGHT TABLE MOUNTED FLOOR TAEP-02 29.7000 76.7000 37.0000 325.0000 115.0000 60.0000 12.5000 POWER EXAM TABLE WITH POWER HEIGHT ADJUSTMENT, ADJUSTS OWNER CONTRACTOR CONDUIT, CABLES, CONTRACTOR
(253-002) FROM MINIMUM 18" HEIGHT TO 37" MAXIMUM HEIGHT, POWER FOOT FACE PLATE
CONTROL, 400 LB. PATIENT WEIGHT CAPACITY, POWER BACK,
ADJUSTABLE STIRRUPS WITH FOUR LATERAL POSITIONS, FOOT
EXTENSION SHELF TO EXPAND TABLE LENGTH, HOSPITAL GRADE
ELECTRICAL RECEPTACLE, PAPER ROLL HOLDER HIDDEN UNDER
HEADREST, BUILT-IN PILLOW STORAGE, TREATMENT PAN AND
LEVELING SCREWS; DRAWER SYSTEM; **SPECIFY UPHOLSTERY
COLOR WHEN ORDERING.**
EXAM ROOM WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 1.0000 1.0000 1.0000 FLOOR WACB-01 12.0000 12.0000 17.0000 18.0000 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
EXAM ROOM WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1.0000 1.0000 1.0000 FLOOR WARE-01 19.7000 12.2000 31.6000 14.3000 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
EXAM ROOM WALL MOUNTED TBD TBD 1.0000 1.0000 1.0000 WALL X OWNER CONTRACTOR BLOCKING HENRIKSEN
COMPUTER BRACKET
EXAM ROOM WALL MOUNTED TBD TBD 1.0000 1.0000 1.0000 WALL X OWNER CONTRACTOR CONDUIT, CABLES, OWNER
COMPUTER MOINTOR FACE PLATE
EXAM ROOM MONITOR, PULSE MASIMO CORP RADICAL 7 RDS-3 1 1 1 CTRTOP OWNER CONTRACTOR CONDUIT OWNER
OXIMETER
1.0000 1.0000 1.0000 15.5000 8.2500 17.3000
MEDICINE ROOM CONTAINER, SHARPS DANIELS SHARPSMART INC S22 1001207500 1.0000 1.0000 1.0000 1 ea. WALL BRACKET WALL COSH-01 8.0000 12.0000 15.0000 REUSABLE SHARPS CONTAINER WITH 16 QUART CAPACITY FOR USE OWNER CONTRACTOR BLOCKING CONTRACTOR
IN MODERATE VOLUME AREAS
MEDICINE ROOM CABINET, STORAGE, Lakeside Manufacturing, Inc LNC - 11D 1.0000 1.0000 1.0000 WALL NARC-01 22.8000 27.0000 55.0000 120.0000 60.0000 OWNER CONTRACTOR BLOCKING CONTRACTOR
CLINICAL, NARCOTICS (2-Door/2-Lock)
MEDICINE ROOM DRUG DISPENSING UNIT PYXIS / CAREFUSION PYXIS ES 6-DRAWER 1.0000 1.0000 1.0000 FLOOR DRDU-01 15.9500 3.9500 10.1000 120 60 ES PLATFORM: 6-DRAWER MAIN UNIT OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MAIN FACE PLATE
MEDICINE ROOM GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 1.0000 3.0000 3.0000 WALL GLBH-01 23.7500 27.0000 31.3800 115.0000 60.0000 4.1000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
MEDICINE ROOM REFRIGERATOR, FOLLETT CORPORATION REF4P-KP-00 1.0000 1.0000 1.0000 FLOOR REUN-01 23.75 27 31.38 115 60 4.1 3.9 CU FT CAPACITY; STAINLESS STEEL REFRIGERATOR WITH OWNER CONTRACTOR CONDUIT OWNER
UNDERCOUNTER KEYPAD LOCK; AUTOMATIC DEFROST. FITS BELOW 34" ADA
COUNTERTOPS WITHOUT CASTERS. DEPTH OF CABINET IS 25.6"D.
DEPTH WITH FAÇADE IS 27".
MEDICINE ROOM Monitor, Blood Glucose Johnson & Johnson / Lifescan Division One Touch Surestep 2.0000 1.0000 2.0000
Flexx
MEDICINE ROOM MONITOR, SMART TEMPS SMART LINK 1.0000 1.0000 1.0000 REFRIGERATOR
MOTE-01 2.3000 5.2000 6.9000 3.9000 WIRELESS TEMPERATURE MONITORING FOR OWNER N/A N/A OWNER
TEMPERATURE REFRIGERATORS/FREEZERS. USED ALONG WITH SMART LINK AND
SMART COMMAND CENTER.
MEDICINE ROOM REMOTE MANAGER PYXIS / CAREFUSION SMART REMOTE 1 1 1 REMA-01
REFRIGERATOR 2.3 5.2 6.9 3.9 TEMPERATURE-SENSITIVE MEDICATION DISPENSING AND OWNER N/A N/A OWNER
MANAGER MONITORING SYSTEM SUPPORTS EFFORTS TO MAINTAIN
REGULATORY COMPLIANCE. INTEGRATES W/PYXIS MEDSTATION TO
PROVIDE CONTROLLED POINT-OF-USE ACCESS AND MONITOR
INTERNAL TEMPERATURES OF STORAGE DEVICES.
ELECTRONICALLY ARCHIVES TRANSACTION AND TEMP DATA AND
GENERATES REPORTS NECESSSARY FOR REGULATORY
COMPLIANCE, INVENTORY MANAGEMENT AND BILLING. INCLUDES
SOFTWARE MODULE, ELECTRONIC LOCKING LATCH AND TEMP
SENSOR W/DISPLAY. CAN BE INSTALLED ON MANY, BUT NOT ALL,
COMMERCIALLY AVAILABLE REFRIGERATORS AND WARMERS. TEMP
ACCURACY +/- 1.9 dg FAHRENHEIT PER 1000 HOURS.
1.0000 1.0000 1.0000 120.00 60.00 13.40
EQUIPMENT REPAIR Dialysate Meter DialyGuard pHoenix 2.0000 1.0000 2.0000 MEDI-01 120.00 60.00 13.40
EQUIPMENT REPAIR Dialysis Machines Fresnius Medical Care North America 2008T 1.0000 1.0000 1.0000 FLOOR DI-01 12.0000 12.0000 17.0000 18.0000 OWNER CONTRACTOR CONDUIT, CABLES, OWNER
DIALYSIS BOX, RO
WATER PIPNG
EQUIPMENT REPAIR WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 1.0000 1.0000 1.0000 FLOOR WACB-01 15.9500 3.9500 10.1000 18 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
EQUIPMENT REPAIR GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 1.0000 1.0000 1.0000 WALL GLBH-01 19.7000 12.2000 31.6000 14.3000 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
EQUIPMENT REPAIR WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1 1 1 FLOOR WARE-01 19.7 12.2 31.6 14.3 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
2.0000 1.0000 2.0000
CLEAN SUPPLY Pump, Infusion, Single B. Braun Medical Inc. Outlook 300 2.0000 1.0000 2.0000 PINF-01 OWNER OWNER
CLEAN SUPPLY Regulator, Suction, Allied Healthcare Products - Vacutron 22-15-1108 2.0000 1.0000 2.0000 REGI-01 48.0000 24.0000 72.0000 OWNER OWNER

CLEAN SUPPLY
Intermittent/Continous
Flowmeter, Oxygen
Chemetron
Precision Medical Incorporated Chrome (0-15 lpm, 2 1 2 MFLO-01
Holabird & Root, LLC expressly disclaims any
CLEAN SUPPLY CART, SUPPLY INTERMETRO INDUSTRIES CORP. /
DISS Female)
1.0000 1.0000 1.0000 FLOOR CASU-02 23.7500 27.0000 31.3800 115.0000 60.0000 4.1000 WIRE CART WITH (5) SHELVES; BOTTOM SHELF TO BE SOLID; SIDE OWNER N/A N/A OWNER
responsibility arising from any unauthorized use of these
METRO INTERNATIONAL AND BACK ENCLOSURE PANELS; DONUT BUMPERS; WITH TWO
SWIVEL CASTERS AND TWO CASTERS WITH BRAKES.
plans, drawings and notes. Any authorization must be in
1.0000 1.0000 1.0000 12.0000 12.0000 17.0000 18.0000 writing.
LAB REFRIGERATOR, FOLLETT CORPORATION REF4P-KP-00 1.0000 1.0000 1.0000 FLOOR REUN-01 19.7000 12.2000 31.6000 14.3000 115 60 4.1 3.9 CU FT CAPACITY; STAINLESS STEEL REFRIGERATOR WITH OWNER CONTRACTOR CONDUIT OWNER
UNDERCOUNTER KEYPAD LOCK; AUTOMATIC DEFROST. FITS BELOW 34" ADA
COUNTERTOPS WITHOUT CASTERS. DEPTH OF CABINET IS 25.6"D.
DEPTH WITH FAÇADE IS 27". This drawing copy may have been reproduced at a size
LAB WASTE CONTAINER, UNITED RECEPTACLE INC. ST7E 1.0000 1.0000 1.0000 FLOOR WACB-01 15.9500 3.9500 10.1000 18 WASTE RECEPTACLE, 7 GALLON CAPACITY; SQUARE STEEL STEP-ON OWNER N/A N/A OWNER
BIOHAZARD CAN; MEETS OSHA REQUIREMENTS FOR BLOOD BORNE
PATHOGENIC MATERIALS; CALIFORNIA STATE FIRE MARSHALL
different than originally drawn. The Owner and Architect
APPROVED FOR FIRE SAFETY; HEAVY DUTY PEDAL FOR HANDS
FREE; OPTIONAL ANTIMICROBIALLY TREATED RIGID LINER OR
assume no responsibility for use of incorrect scale.
GALVANIZED STEEL LINER; PIANO HINGED LID WITH RESTRAINT
MECHANISM; CUSHIONED STEEL LEGS OR VINYL BASE RING TO Drawings are not to be scaled.
PROTECT FLOORS, REDUCE NOISE. COLOR SELECTIONS: RED,
WHITE, OR ALMOND.
LAB WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1.0000 1.0000 1.0000 FLOOR WARE-01 19.7 12.2 31.6 14.3 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL Not published - All rights reserved.
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
LAB GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 2.0000 1.0000 2.0000 WALL GLBH-01 15.95 3.95 10.1 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
LAB MONITOR, SMART TEMPS SMART LINK 6.0000 1.0000 6.0000 REFRIGERATOR
MOTE-01 9.5000 11.5000 5.2500 WIRELESS TEMPERATURE MONITORING FOR OWNER N/A N/A OWNER
TEMPERATURE REFRIGERATORS/FREEZERS. USED ALONG WITH SMART LINK AND
SMART COMMAND CENTER.
1.0000 2.0000 2.0000 24.0000 24.0000 40.0000 120.0000 60.0000 2.0000
ALCOVE Pump, Suction/Aspirator, SSCOR, Inc 6401.0000 1.0000 1.0000 1.0000 CART PSAS-01 35.0000 22.0000 45.7500 OWNER N/A OWNER
General, Potable
ALCOVE DEFIBRILLATOR, AED ZOLL MEDICAL CORPORATION AED PLUS 1.0000 1.0000 1.0000 1 ea. SEMI-RECESSED WALL DEAE-01 19.0000 27.0000 40.7000 81.0000 115.0000 60.0000 0.5000 AED PLUS WITH AED COVER; INCLUDES: LCD SCREEN SHOWING OWNER CONTRACTOR BLOCKING, CONDUIT OWNER
CABINET (9320-0723) VOICE PROMPT MESSAGES, DEVICE ADVISORY MESSAGES,
ELAPSED TIME, SHOCK COUNT AND CHEST COMPRESSION GRAPH;
SUPPLIED WITH PUBLIC SAFETY PASS COVER, SOFTCASE,
OPERATOR'S GUIDE; (5) FIVE YEAR LIMITED WARRANTY.
ALCOVE MONITOR, VITAL SIGNS WELCH ALLYN CONNEX SPOT 73MT-B 2.0000 1.0000 2.0000 1 ea. POWER MANAGEMENT STAND MOVS-01 22.0000 36.0000 40.0000 120 60 2 CONNEX SPOT MONITOR WITH BLUETOOTH CAPABILITY, BLOOD OWNER CONTRACTOR CONDUIT OWNER
STAND (7000-APM); 2 ea. PRESSURE, MASIMO SPO2 AND SURETEMP THERMOMETER.
BLOOD PRESSURE CUFF,
SMALL ADULT, 1 TUBE
(REUSE101HP); 2 ea. BLOOD
PRESSURE CUFF, ADULT, 1
TUBE (REUSE111HP); 2 ea.
BLOOD PRESSURE CUFF, LG
ADULT, 1 TUBE (REUSE121HP)
ALCOVE Cart, Procedure, Harloff Company, Inc 6401 1 1 1 FLOOR CASU-03 35 22 45.75 6 DRAWER, CARDIAC BOARD AND BRACKETS, DROP SHELF, UTILITY
Resuscitation HOOKS IV POLE, OXYGEN TANK HOLDER -D/E SIZE
ALCOVE ELECTROCARDIOGRAPH GE HEALTHCARE MAC 5500 HD 1.0000 1.0000 1.0000 1 ea. MAC 5500 HD W/ CAMHD CART ELEC-01 20.1300 16.5600 12.0000 34.0000 120.0000 60.0000 13.4000 MAC 5500 HD ELECTROCARDIOGRAPH SYSTEM. DIMENSIONS OF OWNER CONTRACTOR CONDUIT OWNER
AND COLOR (2053900-013); 1 TROLLY 19WX27DX37H
ea. STANDARD PAPER
PACKAGE (2053900-021); 1 ea.
ENGLISH LANGUAGE
(2053900-023); 1 ea. NORTH
AMERICAN POWER CORD
1 09/07/2018 ISSUED FOR BID
(2053900-069); 1 ea. CAM HD
AHA (2053900-114); 1 ea.
MOBILE LINK WIRELESS WITH
No. Date Issue
NEW TROLLEY BRACKET
(2053900-128); 1 ea. MODULAR
MAC TROLLEY FOR 5500
(2055478-001)
WHEEL CHAIR WHEELCHAIR MEDLINE INDUSTRIES, INC. EXCEL 22" WIDE 1.0000 1.0000 1.0000 FLOOR WHEE-01 32.9000 34.0000 66.8000 120.0000 60.0000 15.0000 EXCEL WHEELCHAIR, SEAT IS 22" W X 18"D, NAVY. WT CAPACITY 500 OWNER N/A N/A OWNER
ALCOVE LBS. TO INCLUDE TELESCOPING IV POLE, OXYGEN TANK HOLDER,
TINNERMAN NUTS FOR LEG RIGGING. DIMENSIONS APPROXIMATE
WHEN FOLDED. Project Number 15849
1.0000 1.0000 1.0000 19.7000 12.2000 31.6000 14.3000
BREAK ROOM MICROWAVE PANASONIC - CONSUMER NE-1054F 1.0000 1 1 COUNTERTOP
MICR-01 20.13 16.56 12 34 120 60 13.4 1000 WATT COMMERCIAL MICROWAVE OVEN; 0.8 CU. FT.; 10 OWNER CONTRACTOR CONDUIT OWNER
ELECTRONICS PROGRAMMABLE MEMORY PADS, "GRAB & GO", DOOR HANDLE AND Drawn S. DENNY
BOTTOM ENERGY FEED, STAINLESS STEEL FINISH, 10
PROGRAMMABLE MEMORY, PADS AND 20 MEMORY CAPABILITY.
BREAK ROOM REFRIGERATOR
FREEZER, UPRIGHT
GE APPLIANCES GTE21GSHSS 1 1 1 FLOOR REFU-01 32.9 34 66.8 120 60 15 21.2 CU. FT. FROST FREE REFRIGERATOR WITH TOP FREEZER AND
UPFRONT TEMPERATURE CONTROLS; 2 GLASS SHELVES; 3 BINS;
OWNER CONTRACTOR CONDUIT OWNER
Checked K. BOYER
DOOR BIN HOLDS GALLON SIZE CONTAINERS. CLEAR
VEGETABLE/FRUIT CRISPERS. ICE MAKER OPTIONAL.
REFRIGERATOR CAPACITY: 15.1 CF; FREEZER CAPACITY: 6.1 CF. Proj. Arch./Eng. K. SCHUSTER
BREAK ROOM WASTE RECEPTACLE RUBBERMAID COMMERCIAL 1883460 1.0000 1.0000 1.0000 FLOOR WARE-01 15.9500 3.9500 10.1000 14.3 "SLIM JIM STEP-ON 68L/18 GAL RESIN FRONT WASTE CONTAINER.
PRODUCTS QUIET, CONTROLLED LID CLOSURE MINIMIZES NOISE. INTERNAL
HINGE DESIGN TO PREVENT WALL DAMAGE. FACTORY MUTUAL
CERTIFIED ENSURES FIRE SAFETY. MEETS OSHA AND OBRA
STANDARDS FOR WORKER AND ENVIRONMENTAL SAFETY. COLOR:
BEIGE.
BREAK ROOM Coffee Maker, Single Cup Keurig, Inc. B200 2.0000 1.0000 2.0000

SOILED STORAGE GLOVE BOX HOLDER BOWMAN MANUFACTURING GP-015-DS 6.0000 1.0000 6.0000 WALL GLBH-01 15.95 3.95 10.1 "TRIPLE BOX" - CLEAR PLASTIC (PETG) PLEXIGLASS DISPENSER OWNER CONTRACTOR BLOCKING CONTRACTOR
HOLDS (3) GLOVE BOXES VERTICALLY; FEATURES OPEN TOP W/

SOILED STORAGE TRUCK/ BIN, WASTE RUBBERMAID COMMERCIAL 4608 1.0000 1.0000 1.0000 1 ea. DOMED HINGED LID (4615) FLOOR TRBW-01 26 38 28
FRONT CUT-OUT FOR DISPENSING FROM BOXES; KEYHOLES FOR
WALL MOUNTING; INSIDE DIMENSION: 5-1/2"W x 3-3/4"D x 10"H
TRUCK/BIN TO HOLD 8 CF.; 5300 LB CAPACITY, SMOOTH ALL PLASTIC OWNER N/A N/A OWNER
Provident Hospital - Renal
SOILED STORAGE Cart/Truck, Soiled Utility
PRODUCTS

Rubbermaid Commercial Products 4608 Cube Truck (8 cu. 1.0000 1.0000 1.0000 FLOOR CATS-01 60.0000 24.0000 79.0000
BODY; METAL FRAME DESIGN, 5" CASTERS--2 FIXED, 2 SWIVEL.
SPECIFY COLOR WHEN ORDERING- AVAILABLE IN DB,G,R,W,Y Dialysis Center
Ft., Black)
2.0000 1.0000 2.0000 48.0000 24.0000 72.0000
STORAGE Headphones TBD TBD 1105.0000 6 1 6 38.0000 85.0000 34.0000
STORAGE Stand, IV, Chrome Brewer Company 11360 (5leg,4-hook) 1.0000 1.0000 1.0000 FLOOR IVST-01
STORAGE CART, SUPPLY INTERMETRO INDUSTRIES CORP. / 1.0000 1.0000 1.0000 FLOOR CASU-01 60 24 79 WIRE CART SUPPLY CART; QTY 4 OWNER N/A N/A OWNER
METRO INTERNATIONAL

STORAGE CART, SUPPLY INTERMETRO INDUSTRIES CORP. / 1.0000 1.0000 1.0000 FLOOR CASU-02 48 24 72 WIRE CART WITH (5) SHELVES; BOTTOM SHELF TO BE SOLID; SIDE OWNER N/A N/A OWNER
METRO INTERNATIONAL AND BACK ENCLOSURE PANELS; DONUT BUMPERS; WITH TWO
SWIVEL CASTERS AND TWO CASTERS WITH BRAKES.
STORAGE STRETCHER STRYKER 5 WHEEL 30" 1105 1.0000 1.0000 1.0000 FLOOR STRT-02 38 85 34

STORAGE WHEELCHAIR, BARIATRIC MEDLINE INDUSTRIES, INC. MDS809750 1.0000 1.0000 1.0000 FLOOR WHBA-01 SHUTTLE BARIATRIC WHEELCHAIR, SEAT WIDTH 26". ELEVATING OWNER N/A N/A OWNER
LEGS. REMOVEABLE DESK LENGTH ARMS. 850 LB WEIGHT CAPACITY.
2.0000 1.0000 2.0000 8.0000
RECEPTION PC COMPUTER WITH TBD TBD TBD 1.0000 1.0000 1.0000 CTRTP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE
AND MOUSE
RECEPTION Copier, Printer, Multifunction Canon USA, Inc Image Runner 1630 1.0000 1.0000 1.0000 FLOOR COPM-01
RECEPTION Bin, Shredding, Secure Shred-it, Inc. Standard Console 1.0000 1.0000 1.0000 CTRTP BINS-01
MEETING ROOM PC COMPUTER WITH
MONITOR, KEYBOARD,
TBD TBD TBD 1.0000 1.0000 1.0000 8 CTRTP OWNER CONTRACTOR CONDUIT, CABLES,
FACE PLATE
OWNER 430 East 51st Place
CONFERENCE
AND MOUSE
AV CABINET TBD TBD TBD 1.0000 1.0000 1.0000 FLOOR CAV-01
Chicago, Illinois 60615
SOCIAL WORKER PC COMPUTER WITH TBD 2955.0000 TBD 1.0000 4.0000 4.0000 CTRTP 11.4000 8.2500 12.0000 OWNER CONTRACTOR CONDUIT, CABLES, OWNER
OFFICE MONITOR, KEYBOARD, FACE PLATE
AND MOUSE
STAFF OFFICE PC COMPUTER WITH TBD TBD TBD 1.0000 4.0000 4.0000 CTRTP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE Project Name
AND MOUSE
CLINIC MANAGER PC COMPUTER WITH TBD TBD TBD 1 1 1 CTRTP OWNER CONTRACTOR CONDUIT, CABLES, OWNER
MONITOR, KEYBOARD, FACE PLATE
AND MOUSE
DIETICIAN OFFICE PC COMPUTER WITH
MONITOR, KEYBOARD,
AND MOUSE
TBD TBD TBD 1.0000 1 1 CTRTP DELL, VOSTRO MINI TOWER & E1911-19" MONITOR OWNER CONTRACTOR CONDUIT, CABLES,
FACE PLATE
OWNER
OWNER EQUIPMENT SCHEDULE
OFFICES WASTE RECEPTACLE RUBBERMAID COMMERCIAL 2955 1.0000 4 4 FLOOR WARE-02 11.4 8.25 12 SMALL DESKSIDE, 8 GAL, BIEGE OWNER N/A N/A OWNER
PRODUCTS
VARIOUS Clock, Analog, Wall Primex Wireless Traditional 12.5"/Black 1 4 4 WALL OWNER CONTRACTOR BLOCKING CONTRACTOR
[14155]

JANITORS CLOSET BUCKET, MOPPING RUBERMAID COMMERCIAL Q950 - HYGEN 1 FLOOR


PRODUCTS Microber Charging Sheet Name
Bucket
JANITORS CLOSET CART, HOUSEKEEPING, GEERPRES INC ESCORT RX 3661 1 FLOOR

Q1-1
STAINLESS

WATER
TREATMENT ROOM
Water Treatment System MarCor CONTRACTOR CONTRACTOR CONDUIT, CABLES,
PIPING, EQUIP PADS,
CONTRACTOR Drawing No.
BLOCKING