1 Tag No.

Quantity PT-4024E 1 (One)


2 Service Steam Atomizing to Flare Tips
GENERAL 3 P&ID No. SNO-R-PI-711
4 Line No. 2"-LS-0502-3A
5 NACE Requirement No
6 Harzardous Area Classification Protection Method Zone-2, Gr. IIB, T3 Exi
7 Ingress Protection Tropicalization IP65 Yes
8
9 Fluid State Steam Vapor
10 Design Pressure (psig) Design Temperature (°F) 520 + F.V. 475
CONDITION
SERVICE

11 UNIT MAXIMUM NORMAL MINIMUM


12 Pressure psig 429.6
13 Temperature °F 364
14 Alarm Set Point LL L H HH psig
15
16 Type Smart Type , Foundation Fieldbus
17 Mounting 2" Pipe Mounting with Bracket
18 Element Type Diaphragm
19 Element Material 316SS
20 Process Connection 1/2" NPT
21 Body Material Rating 316SS
TRANSMITTER

22 Wetted O-Rings Material 316SS


23 Bolt and Nuts Material SS316
24 Housing Material Paint Cast Aluminum Alloy High anti-corrosion coating
25 Output Signal Foundation Fieldbus
26 Power Suppy 24VDC Loop Power
27 Accuracy Repeatability +/- 0.1% of span +/- 0.1% of span
28 Temperature effect +/- 0.1% of span/ 50DegF variation
29 Adjustable Range (Instrument Range) 0 ~ 720 psig
30 Set Range (Calibration Range) 0 ~ 450 psig
31 Electrical Connection 1/2" NPT
32
33 Process Connection Size Rating N/A N/A
34 Diaphragm Material Fill Fluid N/A N/A
DIAPHRAGM

35 Capillary Material Capillary Length N/A N/A


SEAL

36 Armor Material N/A


37 Allowable Over Temperature Yes
38 Flushing connection ring N/A
39
40 Intergral Meter Scale LCD Same as set range
41 Mounting Bracket Type Yes Flat Type
42 Valve Manifold Type Material Integral 2-way Manifold 316SS
43 Cable Gland Supplied by Purchaser
44 Calibration Certificate Yes
ACCESSORIES

45 Calibration Report Yes


46 Material Certificate Yes
47 Hydrostatic Testing Yes
48 Material Tagging Plate 316SS
49 Surge protector Yes
50 Tee Equal 316 SS 1/2" T Yes
51 Needle Valve MAT'L SS 316 ,1/2" NPTF Yes
52 Plug 316 SS 1/2" NPT Yes
53 Tubing 316SS
54 Other Tubing Connection Accessories Yes, as per hookup
51 Manufacturer VTA
PURCHASE

52 Model VTA
53 Requisition Number
54 Purchase Order Number
55
Notes :
1. Vendor shall refer to SNO-I-ES-001 "Standard specification for Engineering & Design of instrumentation system".
2. Electronic transmitter shall be capacitance type.
3. FISCO certification is required for FF transmitters.

INSTRUMENT DATASHEET FOR


PRESSURE TRANSMITTER

0 21/10/2020 GFP / DRS Approved for Construction Sheet 219 of 220


REV. DATE BY DESCRIPTION Doc. No. : SNO-I-DS-017 REV. : 0
1 Tag No. Quantity PT-4024F 1 (One)
2 Service Steam Atomizing to Flare Tips
GENERAL 3 P&ID No. SNO-R-PI-126
4 Line No. 2"-LS-0503-3A
5 NACE Requirement No
6 Harzardous Area Classification Protection Method Zone-2, Gr. IIB, T3 Exi
7 Ingress Protection Tropicalization IP65 Yes
8
9 Fluid State Steam Vapor
10 Design Pressure (psig) Design Temperature (°F) 520 + F.V. 475
CONDITION
SERVICE

11 UNIT MAXIMUM NORMAL MINIMUM


12 Pressure psig 220
13 Temperature °F 402
14 Alarm Set Point LL L H HH psig
15
16 Type Smart Type , Foundation Fieldbus
17 Mounting 2" Pipe Mounting with Bracket
18 Element Type Diaphragm
19 Element Material 316SS
20 Process Connection 1/2" NPT
21 Body Material Rating 316SS
TRANSMITTER

22 Wetted O-Rings Material 316SS


23 Bolt and Nuts Material SS316
24 Housing Material Paint Cast Aluminum Alloy High anti-corrosion coating
25 Output Signal Foundation Fieldbus
26 Power Suppy 24VDC Loop Power
27 Accuracy Repeatability +/- 0.1% of span +/- 0.1% of span
28 Temperature effect +/- 0.1% of span/ 50DegF variation
29 Adjustable Range (Instrument Range) 0 ~ 720 psig
30 Set Range (Calibration Range) 0 ~ 450 psig
31 Electrical Connection 1/2" NPT
32
33 Process Connection Size Rating N/A N/A
34 Diaphragm Material Fill Fluid N/A N/A
DIAPHRAGM

35 Capillary Material Capillary Length N/A N/A


SEAL

36 Armor Material N/A


37 Allowable Over Temperature Yes
38 Flushing connection ring N/A
39
40 Intergral Meter Scale LCD Same as set range
41 Mounting Bracket Type Yes Flat Type
42 Valve Manifold Type Material Integral 2-way Manifold 316SS
43 Cable Gland Supplied by Purchaser
44 Calibration Certificate Yes
ACCESSORIES

45 Calibration Report Yes


46 Material Certificate Yes
47 Hydrostatic Testing Yes
48 Material Tagging Plate 316SS
49 Surge protector Yes
50 Tee Equal 316 SS 1/2" T Yes
51 Needle Valve MAT'L SS 316 ,1/2" NPTF Yes
52 Plug 316 SS 1/2" NPT Yes
53 Tubing 316SS
54 Other Tubing Connection Accessories Yes, as per hookup
51 Manufacturer VTA
PURCHASE

52 Model VTA
53 Requisition Number
54 Purchase Order Number
55
Notes :
1. Vendor shall refer to SNO-I-ES-001 "Standard specification for Engineering & Design of instrumentation system".
2. Electronic transmitter shall be capacitance type.
3. FISCO certification is required for FF transmitters.

INSTRUMENT DATASHEET FOR


PRESSURE TRANSMITTER

0 21/10/2020 GFP / DRS Approved for Construction Sheet 220 of 220