GENERAL NOTES

NOTES: 1. This drawing is for design intent purposes only and is not to be scaled.
2. All dimensions shown are in millimeters and are taken from the applied
finishes.
1. DRAWING TO BE READ IN CONJUNCTION WITH :
3. All dimensions are to be verified on site by the contractor prior to
 A32 SERIES DRAWINGS manufacture and installation.
 ID DOOR SCHEDULE 4. Any omissions or discrepancies found shall be reported to the ID
 ID FINISHES SCHEDULE consultant / Engineer immediately for clarification.
5. This drawing is to be read in conjunction with the relevant section of the
2. FOR ALL WINDOWS REFER TO ARCHITECTS specifications, schedules and drawings referenced.
WINDOW SCHEDULE. 6. All necessary structural supports to all items including ceiling hung, wall
3. FOR INTERCONNECTING DOORS VARIANTS REFER hung, built-in units or cantilevered items shall be of adequate strength to
TO GENERAL ARRANGEMENT KEYPLAN DRAWINGS ensure stability and shall be considered by the contractor.
7. The contractor shall submit full shop / setting out drawings for approval
(based on site dimensions) prior to commencement of any site works, or
placing any orders and on manufacture of any fittings, fixtures and
components shown.
8. All work must conform to municipality regulations, national and
international building code and all regulations by governing authorities.
9. The contractor must ensure all coordination between his work, his
subcontractors and the ID consultant's design.
10. All interior finishes must have a flame-spread rating and smoke density
rating to meet or exceed local code requirements.

REVISIONS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
NO DATE DESCRIPTION REV BY
C0 26.SEP.2019 ISSUED FOR CONSTRUCTION ES

NOTE: REFER TO KITCHEN CONSULTANTS


DESIGN ARCHITECTS
FINAL LAYOUT FOR KITCHEN EQUIPMENT
ID-52 AND OPERATION
ADD-06

ID-54
ADD-05

ARCHITECT OF RECORD
1
B (PT)L22-301

ID-72C MALE TOILET FEMALE TOILET


ADD-07
SER.PASSAGE

C
1 OTS OTS
(TD)A73-331

D LIFT-1 LIFT-2 LIFT-3 LIFT-4

1 CU ADD-201 1
1325

E (TD)A78-754
NURSING
ROOM
(TD)A78-753
ID-50 ID-51 565 1000 1200 1000 1200 1000 1550 1000 615 ID-51 ID-50 G A J Middle East
ADD-04 ADD-03 10270 LIFT DOOR LIFT DOOR LIFT DOOR LIFT DOOR 10270 ADD-02 ADD-01
Architectural Consultants
1595

1 ID-53
2

400
600 EQ. 510 1600 510 EQ. 600 600 ADD-08
1445 1220 7060 1000 500 (TD)A78-755 500100 970 3105 1500 3540 1275 (TD)A78-754
1 1
1100

1080
JU ADD-209 (TD)A78-755 (TD)A78-755
JU ADD-209 JU ADD-203A JU ADD-203B
1 1
1

3510
(TD)A78-758
1300

3220

3220

1865
(TD)A78-752A JU ADD-205 (TD)A78-755

JU ADD-208
JU ADD-206 ADD
JU ADD-201A
2080 3000 ALL DAY DINING
1 1 1
F
460

2030 1945 600


JU ADD-203 (TD)A78-757 JU ADD-207 600 1945 2030 (TD)A78-751

CU ADD-202
(TD)A78-757
1
(TD)A78-756
2920

JU ADD-201

2740
2750

KEY PLAN
1 ADD 1
1975

CLIENT
1975

1975

1975

1975
1975

1975

(TD)A78-750 TERRACE (TD)A78-750

MR. MARWAN YASEEN AL ZAEEM


2175

1500

1500

1500

1500

1500

1500

1500
1500

G 700
700 700 700 700
700
ISSUED FOR
TENDER
JU ADD-202A
PROJECT

3423 Hilton Double Tree


Sharjah, UAE
1 LEGEND
(TD)A78-759
BLOCK WORK
(REFER TO ACOUSTIC CONSULTANT DRAWINGS)
DRAWING TITLE
DRY WALL
(REFER TO ACOUSTIC CONSULTANT DRAWINGS) First Floor Level
All Day Dining
NOTE: DRY WALL COMPOSITION SHOULD BE CONSIDERED BASED ON
LOCATION. General Arrangement Plan
A. FOR WET AREAS, WATER AND MOISTURE RESISTANT (SHEET
ROCK TYPE) SHOULD BE CONSIDERED. CONTRACTOR TO
1 PLAN FINALIZE TYPE AND WATER PROOFING MEMBRANE
ACCORDINGLY. Drawn BE Checked HS Approved EC
SCALE-1:100 B. FOR DRY AREAS, CONTRACTOR TO USE NORMAL DRY WALL
- Date Scale
GYPSUM BOARD. CONTRACTOR TO ADVISE ON TYPE AND 07.05.2017 1:100@A1
PROCEED ACCORDINGLY.
Project No. Zone Drawing No. Rev.

INTERIOR DOOR TAG LEGEND 3423(ADD) L22-300 C0


ID-02 DOOR TYPE Authority Dwg. No. Consecutive No.

MU1B-01
DOOR NUMBER
This drawing, the designs and details shown are the copyright of
ZONE CODE G A J MIDDLE EAST Architectural Consultants and shall not
be copied or reproduced in any form without their written consent.
NOT IN ID SCOPE REFER TO ARCH. DRAWING
T:+971 4 323 7555 E: mail@gaj-uae.ae
F:+971 4 323 7717 W: www.godwinaustenjohnson.com
A1 Original Sheet FILE PATH : \\Plutus\data\- PROJECTS CURRENT\3423 - Hilton Double Tree SHJ\LIVE\ACAD\Sheets\1.0 Public Areas\C. All Day Dining\3423-(ADD)L22-300.dwg 26 Sep, 2019 -