Professional Documents
Culture Documents
Description
The P01803 fiber termination box is a compact indoor wall mount enclosure for interconnectivity and termination
of optical fibers. Its' small size is ideal for use in tight closets, inside cabinets and enclosures.
This termination box can be flexibly houses with Interchangeable adapter plates for different applications. It is
made of high-quality steel which delivers superior durability to satisfy your wall mount cabling management need.
Features
. Small splice tray accommodates up to 12 fibers. . Compact size, Ideal for small locations.
. Box accommodate one fiber adapter plate. . Options of 6, 8, 12 fiber capacity.
. Adapter plates feature multiple style adapters. . Offers flexibility in adding or changing connector style.
Specifications
Adapter plate are pre-loaded with 6 (single density), 8 (single density) or 12 (double density) adapters. Blank
adapter plates shall be available to fill unused areas. Simple captive push/pull design make adapter plate easy
to install and remove.
Description Drawing
FC (D type) Adapters
with Plate, Fully Loaded-
6 Ports
FC (D type) Adapters
with Plate, Fully Loaded-
8 Ports
P01803 termination box is the ideal equipment between optical node and terminal. With the function of fusion splice,
fiber storage and wiring distributions. Select the adapter plate and pigtail as required. Here, uses the 12 ports SC
adapter Plate and SC connector pigtail as an example.
2 Pigtails Routing
Connect the pigtail connectors to the adapter plate in sequence, leave a certain surplus length for winding at the bottom
of the box body, and then lead it into the removable splicing tray for fixing (ensure that the radius of curvature at the
bend is greater than 40mm). Figure 1~2 shows the pigtail routing from the rear of the adapter plate to the removable
splicing tray area.
Figure 1 Figure 2
3 Incoming Cable Routing
3.1 Install Cable Gland
Install fiber cable gland fittings in openings on box body as needed to accommodate cables entering box. fiber cable
into box through cable gland, and tighten cable gland fitting around cables to secure them. See figure 3 and figure 4.
Figure 3 Figure 4
Figure 5 Figure 6
4 Fiber Splicing
Incoming Cable spliced with pigtails in the splicing fixed module as shown in figure 7 and figure 8.
Figure 7 Figure 8
Box Installation
The fiber termination box can be installed on the wall mounted or DIN rail mounted according to actual needs.