Professional Documents
Culture Documents
Installation and Commissioning Instructions: LZ 1 - 2,5 A - (KNX) - N
Installation and Commissioning Instructions: LZ 1 - 2,5 A - (KNX) - N
Instructions
Abbreviations
Warning and Safety Symbols
Target Groups, Intended Use
Safety Instructions
01 3-8
02 9
03 10
Certificates
05 13 - 15
06
07
08
Installation instruction
2 LZ 1 - Natural ventilation control unit
PRELIMINARY REMARK
ABBREVIATIONS
Index of abbreviations Scale units
These abbreviations are used consistently throughout these °C Degree Celsius
assembly & operating instructions. Unless stated differently, all dimen- A Amps
sions indicated in this document are in mm.
General tolerances in accordance with DIN ISO 2768-m. Ah Amp-hours
Kg Kilogram
01
aP Surface mounting
m Metres
WxHxD Width x Height x Depth
min Minutes
CAN CAN-BUS mm Millimeters
CM Control Module N Newtons
IN Input W Watts
Ω/kΩ Ohm / kilo-Ohm
OUT Output
Useful note
for an optimum installation.
Installation instruction
LZ 1 - Natural ventilation control unit 3
PRELIMINARY REMARK
TARGET GROUP
These instructions are intended for personnel trained in This device is not intended for use by per-
electrical engineering and skilled operators of systems
! WARNING sons (including children) with physical,
for natural smoke ventilation (NRA / SHEV) (natural smo- sensory or mental limitations or lacking experience and / or
ke exhaust system / smoke and heat exhaust system) and knowledge, unless they are supervised by a person who is
01 natural ventilation via windows, who are knowledgeable responsible for the safety or were instructed by him on the
of operating modes and remaining risks of the system. usage of this equipment. Children should be supervised to
ensure that they are not playing with this device.
Cleaning and operator’s maintenance may not be per-
formed by children without supervision.
INTENDED USE
Area of application / Scope of application
This control device is intended for power-feeding and con- Attention must be paid to possible
trolling electromotive operated windows in facade and roof hazards when used with tilting or
areas. The prime task of this product, in combination rotating windows, whose secondary
with the electromotive window, is to evacuate hot smoke ! WARNING closing edges are located at less than
and combustion gases in case of fire to save human 2,5 m installation height above the floor,
lives and protect material assets. Furthermore, the electro- under consideration of the Control Unit
motive operated window ensures fresh air supply for the and usage!
natural ventilation of the building. We as manufacturers are well aware of our duties and
By installing the drive to a movable ele- responsibilities regarding the development, manufactu-
ment of the window a so-called “pow- ring and placing of safe window drives on the market and
er-operated window” is created which, consistently implement them. Ultimately, however, we have
according to the Machinery Directive no direct influence on the usage of our drives. Therefore,
2006/42/EG, represents a machine. The as a precaution, we point out the following:
NOTE control device is designated for driving
such a window. Where it seems reason- • The constructor or his agent (architect, specialist
able, these installation instructions point planner) are obligated by law to evaluate the
out sensibly predictable hazards and risks hazards to persons, originating from the usage,
resulting from a power operated window. installation position, opening parameters as well as
the planned type of installation of the power
Intended use according to the Declaration of Con- operated window and the external Control Unit,
formity already in the planning phase and to establish
The control device is intended for stationary installation and necessary protective measures.
electrical connection as part of a building. • The constructor / manufacturer of the machine
In accordance with the attached Declaration of Con- “power-operated window” must implement the
formity the control device, in combination with elec- planned protective measures at the installation site
tromotive drives from AUMÜLLER, is released for or, if not yet established, determine them by theire
its intended use in a power-operated window own responsibility and detect or minimize possible
without an additional on-site risk assessment for the remaining risks.
following use: By connecting the window drives with
• Natural ventilation a control device and their operation the
with an installation height of the drive of at least constructor of the complete system beco-
2,5 m above the floor, or mes the manufacturer of the power-ope-
with an opening width at the HSK of the operated rated window! If necessary, he is obliga-
element of < 200 mm by a simultaneous speed of NOTE ted to perform a risk assessment of the
< 15 mm/s at the HSK in closing direction. complete system in accordance with the
• Application as NSHEV (natural smoke and heat Machinery Directive 2006/42/EG when
exhaust ventilators) for ventilation without dual the utilization or operation of the control
purpose for ventilation in accordance with device or the connected window drives
EN12101-2. deviate from their intended use!
Installation instruction
4 LZ 1 - Natural ventilation control unit
PRELIMINARY REMARK
The need for a risk assessment at the installation site • the installation height of the drive is < 2,5 m above the
due to the reasonably foreseeable misuse. floor and
A risk assessment in accordance with the Machinery • the opening width at the HSK > 200 mm, or
Directive 2006 / 42 / EG by activation of the power- • the closing speed at the HSK is > 15 mm/s, or
operated window for natural ventilation is absolutely • the opening speed at the HSK is > 50 mm/s, or 01
necessary under the following conditions: • the closing force at the HSK is > 150 N
The following flow chart can be applied, which also includes
the protective measures in accordance with EN 60335-2-
103/2016-05.
NSHEV in accordance
NSHEV in accordance
with EN12101-2
with EN12101-2 Using drives
with dual purpose for ventilation
without dual purpose for ventilation
(1.Z.109)
! CAUTION
Protection devices
Hold-to-run switch:
stops movement at HSK < 20 mm Contact-free anti-trap protection Contact-based anti-trap protection
at a closing force of > 150 N at HSK (20.ZAA.8.1) (20.ZAA.8.2)
(20.ZAA.5)
Installation instruction
LZ 1 - Natural ventilation control unit 5
SAFETY INSTRUCTIONS
We recommend using exclusively sys- Basic functions of SHEV (smoke and heat exhaust sys-
tem components by AUMÜLLER, because tem) control devices:
their compatibility is carefully checked • Control of electromotive window drives for smoke
in the factory. AUMÜLLER shall not assume and heat exhaust in case of fire and for “natural
01 liability for the system-compatible func- ventilation”.
tioning of third party components. • Evaluation of trigger signals of manual and automatic
Applications and connections other than smoke detectors as well as of fire alarm systems.
NOTE explicitly described in these instructions • Emergency power supply provided by batteries for main-
require the express written consent of taining safety functions if power supply is interrupted in
AUMÜLLER. Utilization of applications and case of fire.
components not expressly authorized by • Monitoring the power supply of all important con-
AUMÜLLER are considered as unintended nections for malfunctions.
use even if their perfect functioning is • Diverse automatic and manual control options for con-
proven at commissioning (e.g. approval trolling natural ventilation (e.g. via wind and rain
under building law). sensors).
• Transmission of signals of all essential operating states
for external evaluation (may require additional com-
ponents).
• Comfortable configuration and parameterization of
control via PC software.
• Optional integration into external data bus systems via
dd-on modules.
SAFETY INSTRUCTIONS
It is important to follow these instruc- Crush and shear points
tions for the safety of persons. These To avoid injuries, crushing and shear points between
! WARNING
instructions shall be kept in a safe place casement and frame must be secured against entrapment
for the entire service life of the products. up to an installation height of 2,5 meters above the
floor with appropriate measures. This can be achieved e.g.
Risk of crushing and entrapment!
by using contact-based or contactless protective devices
Electromotive operated windows can
against entrapment, which stop the motion through contact
close automatically!
or through interruption by a person. A warning symbol at
The compressive force is absolutely
the opening element must indicate this clearly.
sufficient to crush fingers in case of
carelessness.
Routing cables and electrical connection
Area of application Routing or installing electrical lines and connections may
The control device shall only be used according to its inten- be performed only by approved specialist companies. Never
ded use. For additional applications consult the manufactu- operate drives, Control Units, operating elements and sen-
rer or his authorized dealer. sors at operating voltages and connections contrary to the
specifications of the manufacturer.
Installation
These instructions address expert and safety-conscious The planning and calculation of the
electricians and / or qualified personnel knowledgeable of wiring system is the responsibility of
the electrical and mechanical installation of drives and con- NOTE the builder or his agent or the authori-
trol systems. zed constructor and must be performed
according to the statutory provisions.
Mounting material All relevant instructions shall be observed for the in-
The required mounting material must be modified to fit the stallation, specifically:
occurring load. • VDE 0100 Setting up high-voltage systems up to 1000 V
• VDE 0815 Wiring cables
• Specimen Guideline on Conduits German designation
(MLAR).
Installation instruction
6 LZ 1 - Natural ventilation control unit
SAFETY INSTRUCTIONS
The power line on-site must be secured se- Other persons must be kept away from
parately and provided all poles separators. the casement when a hold-to-run switch
After opening of the system housing voltage (pushbutton) is operated or when a
carrying parts are exposed. The system must ! CAUTION window, which has been opened by a
be separated from the power supply and bat- smoke and heat exhaust system, is clo- 01
tery voltage before each intervention in the sing!
Control Unit of the system. The operating element of hold-to-run
switches must be installed within di-
The types of cable, cable lengths and cross-sections shall rect view from the window, but apart
be selected in accordance with the manufacturer’s technical from moving elements. If the switch is
data. If necessary, the cable types shall be coordinated with
! CAUTION
not a key-operated switch it must be
the competent local authorities and energy supply com- installed at a minimum height of 1,5 m
panies. Low-voltage lines (24 V DC) shall be routed and inaccessible to the public!
separate from the high-voltage lines. Flexible cables may
not be flush-mounted. Freely suspended cables shall be Do not allow children to play with
equipped with strain reliefs. ! CAUTION permanently mounted control devices
and keep remote controls out of reach
Cables must be laid such way that they cannot for children!
be sheared off, twisted or bent during operati- Before working on the system it must be com-
on. It is recommended to perform an insulati- pletely disconnected from the power supply
on measurement of the system’s line network and emergency power supply (e.g. batteries)
and to document this. and secured against unintentional reactiva-
tion. While working in the Control Unit the
Clamping points shall be checked for tightness of threa-
workplace must be secured to prevent un-
ded connections and cable ends. Access to junction boxes,
authorized access. It must be ensured that
clamping points and external drive control systems shall be
unauthorized personnel are unable to open
ensured for maintenance work.
the Control Unit.
Commissioning, operation and maintenance
After the installation and after each modification in The installation instructions of system components (smo-
the set up all functions shall be checked with a trial run. ke detector, natural smoke and heat exhaust ventilators,
After the installation of the system is completed the drives, etc.) are part of the documentation for the complete
end-user shall be introduced to all important operating system and must be kept accessible for authorized quali-
steps. If necessary, he must be advised of all remaining risks / fied personnel, together with the installation and operating
dangers. instructions, for the entire service life of the system.
The end-user shall be instructed in intended use of the
drives and, if necessary, the safety instructions. The end-user Check all functions of the system before
shall be specifically instructed that no additional forces,
! WARNING releasing it for operation.
except for the pressure and tension in the opening and
closing direction of the casement, may be applied to the Software terms and conditions
spindle, chain or lever of the drive. The Control Unit is configured by the factory for the inten-
ded use (standard configuration). The software, especially
NOTE Post warning signs! developed for this Control Unit, allows a quick and easy
adjustment of the factory setting to the respective re-
During the proper assembly of drives with mounting quirements. Furthermore, the system status can be saved,
elements at a window, and the connection to an external retrieved and printed.
Control Unit, the interfaces resulting from mechanical and
Modifiable standard configurations are parti-
electrical performance characteristics of single elements
cularly emphasized in these instructions. The
shall be observed.
software is part of the shipment of the Control
USB
It is imperative that the information Unit. The functional range of this unlicensed
provided in the installation instructions version can be expanded by activation against
! WARNING
of the controlled window drives are ob- payment (license).
served and adhered to!
Installation instruction
LZ 1 - Natural ventilation control unit 7
SAFETY INSTRUCTIONS
The prerequisites of the system (see chapter “SYSTEMS CON- Declaration of Conformity
FIGURATION OF SOFTWARE”) must be checked prior to the instal- The control device is manufactured and inspected for its
lation. The “Software clause for handing over the standard intended use in accordance with the European guidelines.
software as part of shipments” of the ZVEI (German Electri- The respective Declaration of Conformity is on hand. In
01 cal and Electronic Manufacturer’s Association) is accepted case the use or operation of the control device or the con-
as legally binding upon installation. See our homepage: nected window drives deviate from this a risk assessment
Firm AUMÜLLER Aumatic GmbH. must be performed for the complete system of power-
(www.aumueller-gmbh.de) operated windows and a Declaration of Conformity ac-
cording to Machinery Directive 2006/42/EG issued as well
as a CE labeling obtained.
The configuration software of the control
USB device largely excludes damages caused by GUIDELINES AND STANDARDS
incorrect settings. As a matter of precaution The most recent state of country-specific laws, regulations,
we point out that AUMÜLLER, as manufacturer, provisions and standards must absolutely be observed du-
cannot assume liability for damages caused ring the installation and for electrical connections.
by using AUMÜLLER software, because AUMÜLLER
These are for instance:
has no influence on a perfect systems environ-
ment or object-specific systems configuration State building code with special construction regulations
such as:
We, therefore, recommend to protect the operating system - Industrial construction guideline
and software of the systems sufficiently against unauthori- - Venue regulations, etc.
zed interference (e.g. by using a password) and to attend MLAR - Sample Guideline on Conduits German desig-
the training provided by the manufacturer. nation
Provisions of the fire protection authorities
Replacement parts TAB (technical connection conditions) of Utility com-
System components shall only be replaced with spare parts panies
of the same manufacturer. There is no liability, warranty or German Regulations for Occupational Insurance
customer service if third-party parts are used. Exclusively Schemes, such as:
original spare parts of the manufacturer shall be used for - ASR A1.6 and 1.7 (substitute for BGR 232)
expansions. Additional standards and guidelines, such as:
EN 60335-2-103 Safety of household and similar elec-
Ambient conditions trical appliances
The product may not be subjected to impacts or falls, or EN 60730-1 Automatic electrical controls
to vibrations, moisture, aggressive vapors or other harmful EN 12101-10 / prEN 12101-9 (ISO 21927-9/10)
environments, unless the manufacturer released it for one Smoke and heat control systems
or more of these environmental conditions. DIN 4102-12 Functional integrity of electric cable
• Operation: systems
Ambient temperature: -5 °C … +40°C VDE 0100 Installation of high-voltage systems up
Relative humidity: < 90% less 20°C; to 1000 V
< 50% less 40°C; VDE 0298 Use of cables
no formation of condensation VDE 0815 Wiring cables (for telecommunication
• Transport / Storage: and data processing systems)
Storage temperature: 0°C … +30°C VDE 0833 Alarm systems
Relative humidity: < 60% VdS-Guidelines: 2593, 2581, 2580, 2592
Accident prevention regulations, in particular:
Accident prevention regulations and workmen’s - VBG 1 „General rules“ and
compensation insurance guidelines - VBG 4 „Electrical systems and equipment“.
For work on or in a building or building part the provisi- For placing on the market, the installation and the operati-
ons and instructions of the respective accident prevention on outside Germany the relevant national laws, regulations,
regulations (UVV and workmen’s compensation insurance standards and safety provisions apply.
guidelines (BGR /ASR) shall be observed and adhered to.
The constructor is responsible for the proper installation or
operation and the issuing of a Declaration of Conformity
according to European guidelines.
Installation instruction
8 LZ 1 - Natural ventilation control unit
DATA SHEET
Feature / Equipment
• DIP switch for the confi guration of the inputs with low priority in jog-switch or dead-man mode.
• Inputs of various LZ1 and/or LZ6 are switchable in parallel.
• With the bus module it is possible to control drives with internal intelligent cut-off switch S12 for controlled natural ventilation via
the BUS protocol.
LZ 1 - 2,5 A - KNX - Natural ventilation control unit 24 V DC - including BI-K - KNX-Interface-Module (Part.-No.: 683999)
Part.-No: 660028
Application: Natural ventilation control panel with power supply for the controlling
of 24 V DC drives in one ventilation group
Feature / Equipment
• DIP switch for the configuration of the inputs with low priority in jog-switch or dead-man mode.
• Inputs of various LZ1 and/or LZ6 are switchable in parallel.
• With the bus module it is possible to control drives with internal intelligent cut-off switch S12 for controlled natural ventilation via
the BUS protocol.
• Including BI-K - KNX-Interface-Module (Part.-No.: 683999)
Installation instruction
LZ 1 - Natural ventilation control unit 9
CIRCUIT DIAGRAM
Operation
CLOSE
OPEN
PE N
Running direction 12
DIP switch 1 2 ON
1 1 2 2 3 3 4 5 Z A C1 Z A C2 Z A C3
LK3
LK3
+ -
Output: 24 V DC, 500 mA
LZ 1 and LZ 6 is possible.
Parallel connection with
ventilation control unit
Secure power
S12
bei S12
supply separately!
optional for
optional
WH
PE N L
230 V AC
BU
BN
BU
BN
50 Hz
CLOSE
CLOSE
CLOSE
OPEN
OPEN
OPEN
M M
24 V DC 24 V DC
e.g. ventilation
alltogether: 2,5 A
push button
1. Priority
2. Priority
3. Priority
e.g. BMS
P1
P2
P3
BK = black
Plug in of ventilation button, as well as BN = brown
weather, time and tempreature controls BU = blue
or singnals of building management system. GN = green
RD = red
WH = white
Installation instruction
10 LZ 1 - Natural ventilation control unit
MAINTENANCE
04
Installation instruction
LZ 1 - Natural ventilation control unit 11
DISPOSAL / WARRANTY
Before dismantling the Control Unit separate same com- • Ignoring instructions and installation requirements in these in-
pletely from the mains! structions.
• Unauthorized constructional modifications at the product or
accessories.
• Disaster situations due to effects of foreign bodies and Acts of God.
04
LIABILITY • Wear and tear.
Point of contact for possible warranty claims or for repair parts or acces-
We reserve the right to change or discontinue products at any time
sories is the responsible branch office or the responsible person at
without prior notice. Illustrations are subject to change. Although we take
Firm AUMÜLLER Aumatic GmbH.
every care to ensure accuracy, we cannot accept liability for the content
Contact data are available at our homepage
of this document.
(www.aumueller-gmbh.de)
Installation instruction
12 LZ 1 - Natural ventilation control unit
CERTIFICATES
05
Installation instruction
LZ 1 - Natural ventilation control unit 13
CERTIFICATES
05
Installation instruction
14 LZ 1 - Natural ventilation control unit
05
Important note:
We are aware of our responsibility, which is why we present life-supporting and value-preserving products with greatest possible conscientiousness.
Although we make every effort to ensure that the data and information are as correct and up-to-date as possible, we still cannot guarantee that
they are free from mistakes and errors.
All information and data contained in this document are subject to alterations without prior notice. Distribution and reproduction of this document
as well as the use and disclosure of its content is not authorized unless expressly approved. Offenders will be held liable for the payment of dama-
ges. All rights reserved in the case of a patent award or utility model registration.
Basically the General Terms and Conditions of Aumüller Automatic GmbH apply to all offers, supplies and services.
The publication of these assembly and commissioning instructions supersedes all previous editions.
Installation instruction
LZ 1 - Natural ventilation control unit 15
AUMÜLLER AUMATIC GMBH Tel. +49 8271 8185-0
Gemeindewald 11 Fax +49 8271 8185-250
86672 Thierhaupten info@aumueller-gmbh.de
www.aumueller-gmbh.de
9000015201_V2.3_KW28/18
9000017000_V0.1_KW05/14