Type A6E450-AN08-01
Motor M6E074-EI

Phase 1~
Nominal voltage VAC 230
Frequency Hz 50

Type of data definition fa


Valid for approval / standard CE
Speed min-1 900
Power input W 145
Current draw A 0.64
Motor capacitor µF 4
Capacitor voltage VDB 400
Max. back pressure Pa 45
Min. ambient temperature °C -25
Max. ambient temperature °C 55
Starting current A 0.88
ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit
Subject to alterations

Data according to ErP directive


Actual Request 2013 Request 2015

Installation category A Overall efficiency ηes % 24.6 24.6 28.6


Efficiency category Static Efficiency grade N 36 36 40
Variable speed drive No Power input Pe kW 0.16
Specific ratio* 1.00 Air flow qv m³/h 2910
* Specific ratio = 1 + pfs / 100 000 Pa Pressure increase pfs Pa 48
Speed n min-1 830
Data definition with optimum efficiency. LU-121014
The ErP data is determined using a motor-impeller combination in a standardised measurement configuration.

www.servorecambios.com
Item no. 12760-5-9980 · Revision 82795 · Release 2014-05-08 · Page 1 / 4 www.sr-electricmotors.com
Barcelona • Telf. (+34) 93 462 08 19 • Fax. (+34) 93 462 07 88
A6E450-AN08-01 AC axial fan
blades with special design (K series)

Technical features

Mass 4 kg
Size 450 mm
Surface of rotor Coated in black
Material of blades PP plastic
Number of blades 5
Direction of air flow "V"
Direction of rotation Counter-clockwise, seen on rotor
Type of protection IP 44; Depending on installation and position as per EN 60034-5
Insulation class "F"
Humidity class F4-1
Max. permissible ambient motor + 80 °C
temp. (transp./ storage)
Min. permissible ambient motor - 40 °C
temp. (transp./storage)
Mounting position Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharge holes Rotor-side
Operation mode S1
Motor bearing Ball bearing
Touch current acc. IEC 60990 < 0.75 mA
(measuring network Fig. 4, TN
system)
Motor protection Thermal overload protector (TOP) wired internally
Cable exit Lateral
Protection class I (if protective earth is connected by customer)
Product conforming to standard EN 60335-1; CE
Approval EAC

www.servorecambios.com
Item no. 12760-5-9980 · Revision 82795 · Release 2014-05-08 · Page 2 / 4 www.sr-electricmotors.com
Barcelona • Telf. (+34) 93 462 08 19 • Fax. (+34) 93 462 07 88
A6E450-AN08-01 AC axial fan
blades with special design (K series)

Product drawing

1 Direction of air flow "V"


2 Depth of screw max. 10 mm
3 Connection line ETFE AWG20, 4 x brass lead tips crimped

Connection screen

U1 blue Z brown U2 black


PE green/yellow

www.servorecambios.com
Item no. 12760-5-9980 · Revision 82795 · Release 2014-05-08 · Page 3 / 4 www.sr-electricmotors.com
Barcelona • Telf. (+34) 93 462 08 19 • Fax. (+34) 93 462 07 88
A6E450-AN08-01 AC axial fan
blades with special design (K series)

Charts: Air flow 50 Hz


Druck p f s[Pa]für Rho=1,2kg/m^3

qv[cfm]
0 500 1.000 1.500 2.000 2.500
68
0,27
66
0,26
64
62 0,25
60 0,24
58
0,23 Air performance measured as per ISO 5801
56 Installation category A. For detailed
0,22 information on the measuring set-up, please
54
contact ebm-papst. Suction-side noise
52 0,21 levels: LwA measured as per ISO 13347 /
50 0,2 LpA measured with 1m distance to fan axis.
48 The values given are valid under the
0,19 measuring conditions mentioned above and
46 4 may vary according to the actual installation
0,18
44 situation. With any deviation from the
42 0,17 standard set-up, the specific values have to
be checked and reviewed with the unit
40 0,16 installed.
38

p fs_E[IN H2O]
0,15
36
pf s[Pa]

0,14
34
32 0,13
3
30 0,12
28 0,11
26
0,1
24
22 0,09
20 0,08
18 0,07
16 2
0,06
14
12 0,05
10 0,04
8 0,03
6
0,02
4
pf s[P

2 0,01
1
a]

0 0
0 500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.500
qv[m^3/h]

Measured values
U f n Pe I qv pfs
V Hz min-1 W A m3/h Pa
1 230 50 900 145 0.64 4415 0
2 230 50 885 149 0.65 4075 15
3 230 50 870 155 0.68 3650 30
4 230 50 850 160 0.70 3040 45
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase

www.servorecambios.com
Item no. 12760-5-9980 · Revision 82795 · Release 2014-05-08 · Page 4 / 4 www.sr-electricmotors.com
Barcelona • Telf. (+34) 93 462 08 19 • Fax. (+34) 93 462 07 88