You are on page 1of 26

TL1 Command Reference Manual 22.

Retrieve Commands

RTRV-PM-{X}

Command Changes Since Previous Feature Package


• Added OSM-4F OTUC3 (300G) Support.

• Added support for OSM-4S, OSM-5C.

• Added support of far-end PM on OSM-4C, OSM-4F.

Description
The RTRV-PM-{X} command instructs the network element (NE) to retrieve its current set of Performance
Monitoring data associated with the selected facility entity.

The following operation rules apply to the RTRV-PM command:


• The MONTM and MONDAT always appears in the output response.

• Output lines are not generated for MONTYPES that are not valid for the given termination and format.

Refer to Operation Rules table below for additional operation rules.

Table 22.96 Operation Rules


IF AND THEN
TMPER=15-MIN The Network Element (NE) is in 15 minute The current 15-minute register is
PM data collection mode and MONTM is retrieved.
null or represents the current time period.

TMPER=15-MIN The NE is in 15 minute PM data collection The command is accepted if


mode and MONDAT and MONTM specify a otherwise syntactically correct.
register that is maintained in the NE (past This acceptance does not depend
32 fifteen minute registers). upon the availability of the data
from the specified register.

TMPER=1-DAY MONDAT is null. The current daily register is


retrieved.

TMPER=1-DAY MONDAT and MONTM specify a register The acceptance does not depend
that is maintained in the NE (past 7 daily upon the availability of the data
registers). from the specified register.

Register specified with MONDAT, VLDTY and MONVAL fields


MONTM and TMPER has no shows NA.
associated data available.

Register specified with MONDAT, The command is denied.


MONTM and TMPER is not supported
or maintained within the NE.

{X} specifies the facility type among the following AIDs:


• Facilities (fac_type): GBEP, TGLAN, FGE, HGE, OC3, OC12, OC48, OC192, STM1, STM4, STM16,
STM64, OCH (for OCH, OCH-L, OCH-P, OCH-OS), ODUF, ODU0, ODU1, ODU2, ODU2E, ODU3,
ODU4, OTU1, OTU2, OTU4, OTUC2, OTUC3, OMS, OSC, STS1, STS3C, STS12C, STS48C,
STS192C.

Restrictions and Exceptions


• The Facility AID must always correspond to the Facility type.

76.MTFP50/30, Rev B January 2018 Page 30-1195


22. Retrieve Commands TL1 Command Reference Manual

• When OCH is used, it represents OCH, OCH-L, OCH-P, OCH-OS.

• When ALL is used as a second modifier, possible value for AID can only be "ALL" or blank. In this case,
it will address all entities except for ODUk montypes.

• When ALL is used as a second modifier, possible value for AID can only be "ALL" or blank. In this case,
it will address all entities except for STSn and ODUk montypes.

• AID is mandatory (can not be blank) unless second modifier is ALL.

• When no MONTYPE is specified, command response will include values for all MONTYPES supported
by the facility or equipment (except for STSn montypes).

• When the threshold level <thlev> parameter is set to 0 for a counter montype, then no automatic
message (TCA) is generated for this montype. Also, any TCAs announced during the time period, prior
to setting the parameter to 0 will still be visible via RTRV-TCA.

• NA is returned for PM parameters when the PM data is valid but not available due to provisioning such
as in the case where an ODUk is not mapped to an OTUk.

• When a supporting layer (for example, OCH-P) is taken OOS, the supported layers (for example, ODUx/
OTUx) will continue count UAS but will inhibit EB/CV, ES, SES counting.

• On OADMRS/OADMRS9, partial is returned for the PM parameters when the PM data is valid but
experienced the event of OPGAINRANGE value change on the module.

• The units for the retrieved delay value on an ODUk entity for DELAY-ODU(current value), DELAY-ODU-
F(floor value) and DELAY-ODU-C(ceiling value) are microseconds.

• PM is not supported for the ODUC2 and ODUC3 facilities on the OSM-4F module.

• Far-end PM is only applicable for OSM-4C and OSM-4F, and are applicable for the OTUC3, OTUC2,
OTU4, ODU4, ODU3, ODU2E, ODU2, ODU1, ODU0 and ODUF layers.

• The following PM are supported for each Module and facilities in this release: (Note: these figures
illustrate performance monitoring points for the various modules in the system. It is not intended to be
an exhaustive list of every performance parameter that is monitored. Please refer to the next 'Montypes
Supported' table for the details.)

• Far-end PM can be enabled and disabled via the SET-PMMODE command.

• Register initialization (via INIT-REG command) is not supported for far-end PM.

• When far-end PM is enabled, 0 is always returned for the far end Errored Blocks montype.

Page 30-1196 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Figure 22.6 PM with OADMRS/OADMRS9

Performance Monitoring
with OADMRS/OADMRS9
TDTN
LOSS,
SONET PM: TDTC
Section PM (CVS, ESS, SESS, SEFSS, UASS)
Line PM (CVL, ESL, SESL, FC-L, UASL)
Path PM (CVP, ESP, SESP, FCP, UASP,
PJCDIFFP, PJCSPDET, PJCSPGEN)

SONET PM:
Section PM (CVS, ESS, SESS, SEFS, UASS)
SSM-2S SONET/OTU
Line PM (CVL, ESL, SESL, FC-L, UASL)
Path PM (CVP, ESP, SESP, FCP, UASP, Section/RS
MFABs PM (OSC)
PJCDIFFP, PJCSPDET, PJCSPGEN)

OADMRS/OADMRS9
OCH-L/OMS/
OPT

ODU PM (TRMT:EB-ODU, ES-ODU, SES-ODU, MFABs


UAS-ODU) OCH/OMS/
OSC/OPR

LOSS,
BE-FEC, UBE-FEC,
CV-OTU, ES-OTU, OSM
SES-OTU, UAS-OTU
EB-ODU, ES-ODU, OPR,
SES-ODU, UAS-ODU, BE-FEC, UBE-FEC,
CVS, ESS, SESS, SEFSS, UASS, CV-OTU, ES-OTU,
SE, DROP, PKT, BCPKT, MCPKT, CRCAE SES-OTU, UAS-OTU,
EB-ODU, ES-ODU, SES-ODU, UAS-ODU,
USPKT, OSPKT, FRAG, JABR, UTIL PSC, PSD
PSC, PSD

For OSM-4C/OSM-4F, only external connections are supported. The following provides an overview of PM
supported on these modules. For details, refer to 'Montypes Supported' tables.

76.MTFP50/30, Rev B January 2018 Page 30-1197


22. Retrieve Commands TL1 Command Reference Manual

Figure 22.7 PM with OSM-4C/OSM-4F

Performance Monitoring
with OSM-4C/OSM-4F TDTN

TDTC

OSM-4C/
OSM-4F

Backplane
Near-end (NEND)
LOSS, OPR, DGD, CD, OSNR
BE-FEC, UBE-FEC, BER-FEC
CV-OTU, ES-OTU, SES-OTU, UAS-OTU
DELAY-ODU
EB-ODU, ES-ODU, SES-ODU, UAS-ODU,
PSC, PSD

Far-end (FEND)
CV-OTU-FE, ES-OTU-FE, SES-OTU-FE, UAS-OTU-FE
EB-ODU-FE, ES-ODU-FE, SES-ODU-FE, UAS-ODU-FE

Montypes Supported

Table 22.97 Montypes Supported


Module/Facilities PM SUPPORTED (MONTYPE) LOCN DIRN

OADMRS/OADMRS9
OCH-L Optical Power Transmitted: OPT (gauge) NEND TDTN

OCH-L Optical Power Received: OPR (gauge) NEND TDTC

OMS Optical Power Transmitted: OPT (gauge) NEND TDTN

OMS Optical Power Received: OPR (gauge) NEND TDTC

OSC Optical Power Received: OPR (gauge) NEND TDTC

OSC Bit Errors: CVS NEND TDTC


Errored Seconds: ESS
Severely Errored Seconds: SES
Severely Errored Frame Seconds: SEFSS
Loss of Signal Seconds: LOSS

OSM-1S
OTU1 Loss of Signal Seconds: LOSS NEND TDTN
OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction: UBE-
FEC
Errored Blocks on OTU: CV-OTU or EB-OTU
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

Page 30-1198 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.97 Montypes Supported (Continued)


Module/Facilities PM SUPPORTED (MONTYPE) LOCN DIRN
ODU1 Errored Block on ODU: EB-ODU NEND RCV
ODU0 Errored Seconds on ODU: ES-ODU
(Related to OTUk) Severely Errored Seconds on ODU: SES-ODU
Unavailable Seconds on ODU: UAS-ODU
Delay Measurement on ODU: DELAY-ODU (gauge)
Protection Switch Count/Duration: PSC, PSD

ODU1 Errored Block on ODU: EB-ODU NEND TRMT


ODU0 Errored Seconds on ODU: ES-ODU
(Related to Non-OTUk Severely Errored Seconds on ODU: SES-ODU
Interfaces) Unavailable Seconds on ODU: UAS-ODU
Delay Measurement on ODU: DELAY-ODU (gauge)
Protection Switch Count/Duration: PSC*, PSD*(*only retrieve)

OC48/STM16 SONET Section PM (CVS, ESS, SESS, SEFSS, UASS) NEND TDTN
OC12/STM4 Loss of Signal Seconds: LOSS
OC3/STM1

GBEP Loss of Signal Seconds: LOSS, NEND TDTN


Symbol Errors: SE
Ethernet PM: DROP, PKT, BCPKT, MCPKT, CRCAE, USPKT,
OSPKT, FRAG, JABR, UTIL (gauge)

OSM-2S
OCH-P Optical Power Received: OPR (gauge) NEND TDTC
OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction: UBE-
FEC
Coding Violations on OTU: CV-OTU
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

OTU2 Loss of Signal Seconds: LOSS NEND TDTN


OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction: UBE-
FEC
Errored Blocks on OTU: CV-OTU or EB-OTU
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

ODU2E Errored Block on ODU: EB-ODU NEND RCV


ODU2 Errored Seconds on ODU: ES-ODU
ODU1 Severely Errored Seconds on ODU: SES-ODU
ODU0 Unavailable Seconds on ODU: UAS-ODU
ODUF Delay Measurement on ODU: DELAY-ODU (gauge)
(Related to OTUk/OCH-P) Protection Switch Count/Duration: PSC, PSD

ODU2E Errored Block on ODU: EB-ODU NEND TRMT


ODU2 Errored Seconds on ODU: ES-ODU
ODU1 Severely Errored Seconds on ODU: SES-ODU
ODU0 Unavailable Seconds on ODU: UAS-ODU
ODUF Delay Measurement on ODU: DELAY-ODU (gauge)
(Related to Client Protection Switch Count/Duration: PSC, PSD
Interfaces)

76.MTFP50/30, Rev B January 2018 Page 30-1199


22. Retrieve Commands TL1 Command Reference Manual

Table 22.97 Montypes Supported (Continued)


Module/Facilities PM SUPPORTED (MONTYPE) LOCN DIRN
OC192 SONET Section PM (CVS, ESS, SESS, SEFSS, UASS) NEND TDTN
Loss of Signal Seconds: LOSS
Protection Switch Count/Duration: PSC, PSD

TGLAN Loss of Signal Seconds: LOSS NEND TDTN


Symbol Errors: SE
Ethernet: DROP, PKT, BCPKT, MCPKT, CRCAE, USPKT,
OSPKT, FRAG, JABR, UTIL (gauge)
Protection Switch Count/Duration: PSC, PSD

OSM-2C
OCH-P Optical Power Received: OPR (gauge) NEND TDTC
OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction:
UBE-FEC
OTU Bit Error Rate before Forward Error Correction: BER-
FEC (gauge)
Errored Block on OTU: CV-OTU (SONET mode)/EB-
OTU (SDH mode)
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU
Differential Group Delay: DGD (gauge)
Chromatic Dispersion: CD (gauge)
Optical Signal to Noise Ratio: OSNR (gauge)

OTU4 Loss of Signal Seconds: LOSS NEND TDTN


OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction: UBE-
FEC
Errored Blocks on OTU: CV-OTU or EB-OTU
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

ODU4 Errored Block on ODU: EB-ODU NEND RCV


ODU3 Errored Seconds on ODU: ES-ODU
ODU2E Severely Errored Seconds on ODU: SES-ODU
ODU2 Unavailable Seconds on ODU: UAS-ODU
ODU1 Delay Measurement on ODU: DELAY-ODU (gauge)
ODU0 Protection Switch Count/Duration: PSC, PSD
ODUF
(Related to OTUk/OCH-P)

ODU4 Errored Block on ODU: EB-ODU NEND TRMT


ODU3 Errored Seconds on ODU: ES-ODU
ODU2E Severely Errored Seconds on ODU: SES-ODU
ODU2 Unavailable Seconds on ODU: UAS-ODU
ODU1 Delay Measurement on ODU: DELAY-ODU (gauge)
ODU0 Protection Switch Count/Duration: PSC, PSD
ODUF
(Related to Client
Interfaces)

FGE Loss of Signal Seconds: LOSS NEND TDTN


Symbol Errors: SE
Ethernet: DROP, PKT, BCPKT, MCPKT, CRCAE, USPKT,
OSPKT, UTIL (gauge)

Page 30-1200 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.97 Montypes Supported (Continued)


Module/Facilities PM SUPPORTED (MONTYPE) LOCN DIRN
HGE Loss of Signal Seconds: LOSS NEND TDTN
Symbol Errors: SE
Ethernet: DROP, PKT, BCPKT, MCPKT, CRCAE, USPKT,
OSPKT, UTIL (gauge)
Protection Switch Count/Duration: PSC, PSD

SSM-2S
OCn SONET Section PM (CVS, ESS, SESS, SEFSS, UASS) NEND TDTN
Port side SONET Line PM (CVL, ESL, SESL, FC-L, UASL)
Loss of Signal Seconds: LOSS
Protection Switch Count/Duration: PSC, PSD (for 1+1 APS
only)

OCn SONET Section PM (CVS, ESS, SESS, SEFSS, UASS) NEND TDTC
Backplane side with virtual SONET Line PM (CVL, ESL, SESL, FC-L, UASL)
port

ODU2 Errored Block on ODU: EB-ODU NEND TRMT


ODU1 Errored Seconds on ODU: ES-ODU
(Related to backplane OCn Severely Errored Seconds on ODU: SES-ODU
facility with virtual port) Unavailable Seconds on ODU: UAS-ODU
Delay Measurement on ODU: DELAY-ODU (gauge)

STSn SONET Path PM (CVP, ESP, SESP, FCP, UASP, PJCDIFFP, NEND TDTN
Port side PJCSPDET, PJCSPGEN)

STSn SONET Path PM (CVP, ESP, SESP, FCP, UASP, PJCDIFFP, NEND TDTC
Backplane side with virtual PJCSPDET, PJCSPGEN)
port

OSM-4C

OCH-OS Loss of Signal Seconds: LOSS NEND TDTC


Optical Power Received: OPR (gauge)
Bit Error Forward Error Correction: BE-FEC
Uncorrected Block Error Forward Error Correction:
UBE-FEC
Bit Error Rate before Forward Error Correction: BER-FEC
(gauge)
Differential Group Delay: DGD (gauge)
Chromatic Dispersion: CD (gauge)
Optical Signal to Noise Ratio: OSNR (gauge)

OTU4 Errored Blocks on OTU: CV-OTU NEND TDTC


Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

Errored Blocks on OTU: CV-OTU-FE FEND TDTC


Errored Seconds on OTU: ES-OTU-FE
Severely Errored Seconds on OTU: SES-OTU-FE
Unavailable Seconds on OTU: UAS-OTU-FE

76.MTFP50/30, Rev B January 2018 Page 30-1201


22. Retrieve Commands TL1 Command Reference Manual

Table 22.97 Montypes Supported (Continued)


Module/Facilities PM SUPPORTED (MONTYPE) LOCN DIRN
ODU4 Errored Block on ODU: EB-ODU NEND RCV
ODU3 Errored Seconds on ODU: ES-ODU
ODU2E Severely Errored Seconds on ODU: SES-ODU
ODU2 Unavailable Seconds on ODU: UAS-ODU
ODU1 Delay Measurement on ODU: DELAY-ODU (gauge)
ODU0 Protection Switch Count/Duration: PSC, PSD
ODUF
(Related to OTUk/OCH- Errored Block on ODU: EB-ODU-FE FEND RCV
OS) Errored Seconds on ODU: ES-ODU-FE
Severely Errored Seconds on ODU: SES-ODU-FE
Unavailable Seconds on ODU: UAS-ODU-FE

OSM-4F

OCH-OS Loss of Signal Seconds: LOSS NEND TDTC


Optical Power Received: OPR (gauge)
Bit Error Forward Error Correction: BE-FEC
Uncorrected Block Error Forward Error Correction:
UBE-FEC
Bit Error Rate before Forward Error Correction: BER-FEC
(gauge)
Differential Group Delay: DGD (gauge)
Chromatic Dispersion: CD (gauge)
Optical Signal to Noise Ratio: OSNR (gauge)

OTUC2 Errored Blocks on OTU: CV-OTU NEND TDTC


OTUC3 Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

Errored Blocks on OTU: CV-OTU-FE FEND TDTC


Errored Seconds on OTU: ES-OTU-FE
Severely Errored Seconds on OTU: SES-OTU-FE
Unavailable Seconds on OTU: UAS-OTU-FE

OTU4 Errored Blocks on OTU: CV-OTU NEND TDTC


Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

Errored Blocks on OTU: CV-OTU-FE FEND TDTC


Errored Seconds on OTU: ES-OTU-FE
Severely Errored Seconds on OTU: SES-OTU-FE
Unavailable Seconds on OTU: UAS-OTU-FE

ODU4 Errored Block on ODU: EB-ODU NEND RCV


ODU3 Errored Seconds on ODU: ES-ODU
ODU2E Severely Errored Seconds on ODU: SES-ODU
ODU2 Unavailable Seconds on ODU: UAS-ODU
ODU1 Delay Measurement on ODU: DELAY-ODU (gauge)
ODU0 Protection Switch Count/Duration: PSC, PSD
ODUF
(Related to OTUk/OCH- Errored Block on ODU: EB-ODU-FE FEND RCV
OS) Errored Seconds on ODU: ES-ODU-FE
Severely Errored Seconds on ODU: SES-ODU-FE
Unavailable Seconds on ODU: UAS-ODU-FE

OSM-4S

Page 30-1202 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.97 Montypes Supported (Continued)


Module/Facilities PM SUPPORTED (MONTYPE) LOCN DIRN
OCH-P Optical Power Received: OPR (gauge) NEND TDTC
OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction: UBE-
FEC
Errored Block on OTU: CV-OTU or EB-OTU
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

OTU2 Loss of Signal Seconds: LOSS NEND TDTN


OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction: UBE-
FEC
Errored Blocks on OTU: CV-OTU or EB-OTU
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

ODU2E Errored Block on ODU: EB-ODU NEND RCV


ODU2 Errored Seconds on ODU: ES-ODU
ODU1 Severely Errored Seconds on ODU: SES-ODU
ODU0 Unavailable Seconds on ODU: UAS-ODU
ODUF Delay Measurement on ODU: DELAY-ODU (gauge)
(Related to OTU2/OCH-P) Protection Switch Count/Duration: PSC, PSD

ODU2E Errored Block on ODU: EB-ODU NEND TRMT


ODU2 Errored Seconds on ODU: ES-ODU
ODU1 Severely Errored Seconds on ODU: SES-ODU
ODU0 Unavailable Seconds on ODU: UAS-ODU
ODUF Delay Measurement on ODU: DELAY-ODU (gauge)
(Related to Client Protection Switch Count/Duration: PSC, PSD
Interfaces)

TGLAN Loss of Signal Seconds: LOSS NEND TDTN


Symbol Errors: SE
Ethernet: DROP, PKT, BCPKT, MCPKT, CRCAE, USPKT,
OSPKT, FRAG, JABR, UTIL (gauge)

OSM-5C
OTU4 Loss of Signal Seconds: LOSS NEND TDTN
OTU Bit Error Forward Error Correction: BE-FEC
OTU Uncorrected Block Error Forward Error Correction: UBE-
FEC
Errored Blocks on OTU: CV-OTU or EB-OTU
Errored Seconds on OTU: ES-OTU
Severely Errored Seconds on OTU: SES-OTU
Unavailable Seconds on OTU: UAS-OTU

ODU4 Errored Block on ODU: EB-ODU NEND RCV


ODU3 Errored Seconds on ODU: ES-ODU
ODU2E Severely Errored Seconds on ODU: SES-ODU
ODU2 Unavailable Seconds on ODU: UAS-ODU
ODU1 Delay Measurement on ODU: DELAY-ODU (gauge)
ODU0 Protection Switch Count/Duration: PSC, PSD
ODUF
(Related to OTU4)

76.MTFP50/30, Rev B January 2018 Page 30-1203


22. Retrieve Commands TL1 Command Reference Manual

Table 22.97 Montypes Supported (Continued)


Module/Facilities PM SUPPORTED (MONTYPE) LOCN DIRN
ODU4 Errored Block on ODU: EB-ODU NEND TRMT
ODU3 Errored Seconds on ODU: ES-ODU
ODU2E Severely Errored Seconds on ODU: SES-ODU
ODU2 Unavailable Seconds on ODU: UAS-ODU
ODU1 Delay Measurement on ODU: DELAY-ODU (gauge)
ODU0 Protection Switch Count/Duration: PSC, PSD
ODUF
(Related to Client
Interfaces)

HGE Loss of Signal Seconds: LOSS NEND TDTN


Symbol Errors: SE
Ethernet: DROP, PKT, BCPKT, MCPKT, CRCAE, USPKT,
OSPKT, UTIL (gauge)

PM Register Sizes and Default Thresholds

Note: The following tables include Counter and Gauge values. For single value
montypes, they are considered counters (there are no ceiling/floor
thresholds). For multi-value montypes they are considered gauges and
include a base value, a max value and a min value.

Some gauges do not include a min value. Reference the Restrication and
Exceptions section for notes on Gauge limits for specific montypes.

Note: Register sizes for the supported far-end montypes are the same as the
corresponding near-end montypes.

Table 22.98 Performance Monitoring Register Sizes


Counter Size or Gauge Value Threshold Range

Parameter 15-minute 1-day 15-minute 1-day


OPT, OPR at OMS layer -60 dBm to +60 -60 dBm to not supported not supported
dBm +60 dBm
OPT, OPR at OCH layer -60 dBm to +60 -60 dBm to -45 dBm to +20 -45 dBm to +20
dBm +60 dBm dBm dBm
OSC OPR -60 dBm to +60 -60 dBm to -45 dBm to +4 -45 dBm to +4
dBm +60 dBm dBm dBm
BE-FEC (100G) 922337203685 922337203685 1 to 1 to
4775807 4775807 92233720368547 9223372036854
75807 775807
BE-FEC (Applicable to 9.22337E+18 9.22337E+18 1 to 1 to
100G/200G/2X150G on 92233720368547 9223372036854
OCH-OS) 75807 775807

Page 30-1204 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.98 Performance Monitoring Register Sizes (Continued)


Counter Size or Gauge Value Threshold Range

Parameter 15-minute 1-day 15-minute 1-day


BE-FEC (10G) 2147483647 2147483647 1 to 2147483647 1 to 2147483647
(each unit (each unit (each unit (each unit
represents represents represents 8000 represents 8000
8000 errors) 8000 errors) errors) errors)
UBE-FEC, SE 2147483647 2147483647 1 to 2147483647 1 to 2147483647
UBE-FEC (Applicable to 2147483647 2147483647 1 to 2147483647 1 to 2147483647
100G/200G/2X150G on
OCH-OS)

SE (HGE and FGE) 184467440737 184467440737 1 to 1 to


09551615 09551615 18446744073709 1844674407370
551615 9551615
BER-FEC (OCH-P on 1.9E-2 to 2.3E- 1.9E-2 to 2.3E- 1.9E-2 to 2.3E-11 1.9E-2 to 2.3E-
OSM-2C) 11 and 0 11 and 0 and 0 11 and 0
BER-FEC (OCH-OS on 1.9E-2 to 2.3E- 1.9E-2 to 2.3E- 1.9E-2 to 2.3E-11 1.9E-2 to 2.3E-
OSM-4C/OSM-4F with 11 and 0 11 and 0 and 0 11 and 0
15% SDFEC)

BER-FEC (OCH-OS on 0.5 to 1E-11 0.5 to 1E-11 0.5 to 1E-11 and 0 0.5 to 1E-11 and
OSM-4F with 25% and 0 and 0 0
SDFEC)

Ethernet PM: DROP, PKT, 2147483647 2147483647 0 to 2147483647 0 to 2147483647


BCPKT, MCPKT, CRCAE,
USPKT, OSPKT, FRAG,
JABR

Ethernet PM on FGE/ 184467440737 184467440737 0 to 0 to


HGE: DROP, PKT, 09551615 09551615 18446744073709 1844674407370
BCPKT, MCPKT, CRCAE, 551615 9551615
USPKT, OSPKT,UTIL

Ethernet PM: UTIL 100 % 100 % 0 to 100 % 0 to 100 %


CVP 57600000 2147483647 0 to 57600000 0 to 2147483647
CVS, CVL, CV-OTU 57600000 2147483647 1 to 57600000 1 to 2147483647
CV-OTU (OTU4/OTUC2/ 922337203685 922337203685 1 to 1 to
OTUC3), EB-ODU 4775807 4775807 92233720368547 9223372036854
(ODU4), EB-ODUT 75807 775807
(ODU4T)

ESS, SESS, SEFSS, 900 86400 1 to 900 1 to 86400


UASS, ESL, SESL, UASL,
FC-L,
ES-OTU, SES-OTU, UAS-
OTU,
ES-ODU, SES-ODU,
UAS-ODU,
ES-ODUT, SES-ODUT,
UAS-ODUT,
LOSS

76.MTFP50/30, Rev B January 2018 Page 30-1205


22. Retrieve Commands TL1 Command Reference Manual

Table 22.98 Performance Monitoring Register Sizes (Continued)


Counter Size or Gauge Value Threshold Range

Parameter 15-minute 1-day 15-minute 1-day


ESP, SESP, UASP 900 86400 0 to 900 0 to 86400
PJCSPDET, PJCSPGEN 900 86400 0 to 900 0 to 86400
FCP, FCHP 900 86400 0 to 900 0 to 86400
PJCDIFFP 1048575 16777215 0 to 1048575 0 to 16777215
PSC, PSC 18000 17280000 not supported not supported
PSD, PSD 900 s 86400 s not supported not supported
DELAY-ODU, DELAY- 0 to 0 to 0 to 2147483647 0 to 2147483647
ODUT 2147483647 2147483647 us us
us us
DGD (Applicable to 100G 0 to 70 ps 0 to 70 ps 0 to 71 ps 0 to 71 ps
OCH-P)

DGD (Applicable to 100G/ 0 to 100 ps 0 to 100 ps 0 to 101 ps 0 to 101 ps


200G/2X150G OCH-OS)

CD (Applicable to 100G -40000 to -40000 to -40000 to +40000 -40000 to


OCH-P) +40000 ps/nm +40000 ps/nm ps/nm +40000 ps/nm
CD (Applicable to 100G/ -280,000 to -280,000 to -280,000 to -280,000 to
200G/2X150G OCH-OS) +280,000 ps/ +280,000 ps/ +280,000 ps/nm +280,000 ps/nm
nm nm
OSNR (Applicable to LT+12.0, +12.0 LT+12.0, +12.0 0, +12.0 to +20.0 0, +12.0 to +20.0
100G OCH-P) to +20.0, to +20.0, dB dB
GT+20.0 dB GT+20.0 dB
OSNR (Applicable to 0, LT+12.0, 0, LT+12.0, 0, +12.0 to +20.0 0, +12.0 to +20.0
100G/200G/2X150G +12.0 to +20.0, +12.0 to +20.0, dB dB
OCH-OS) GT+20.0 dB GT+20.0 dB

Table 22.99 Default Thresholds OC3 Signal


Default Threshold Value
Monitored Parameter Montype
15-Minute 1-Day
Coding Violation - Section CVS, 140 13440
Background Block Error - RS BBERS

Errored Second - Section/RS ESS, 25 250


ESSRS

Severely Errored Seconds - Section/RS SESS, 4 40


SESSRS

Severely Errored Frame Second - Section SEFSS, 2 8


Out of Frame Seconds - RS OFSRS

Loss of Signal Seconds LOSS 2 8

Page 30-1206 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.99 Default Thresholds OC3 Signal (Continued)


Default Threshold Value
Monitored Parameter Montype
15-Minute 1-Day
Coding Violation - Line CVL, 138 13290
Background Block Error - MS BBEMS

Errored Second - Line/MS ESL, 25 250


ESMS

Severely Errored Seconds - Line/MS SESL, 4 40


SESMS

Unavailable Second - Line/MS UASL, 10 10


Unavailable Second - Section/RS UASMS,
UASS,
UASRS

Failure Count - Line/MS FC-L, 1 1


FCMS

Table 22.100 Default Thresholds for OC12 Signal


Threshold Threshold
Monitored Parameter Montype
15-Minute 1-Day
Coding Violation - Section CVS, 560 53760
Background Block Error - RS BBERS

Errored Second - Section/RS ESS, 25 250


ESSRS

Severely Errored Seconds - Section/RS SESS, 4 40


SESSRS

Severely Errored Frame Second - Section SEFSS, 2 8


Out of Frame Seconds - RS OFSRS

Loss of Signal Seconds LOSS 2 8


Coding Violation - Line CVL, 554 53150
Background Block Error - MS BBEMS

Errored Second - Line/MS ESL, 25 250


ESMS

Severely Errored Seconds - Line/MS SESL, 4 40


SESMS

Unavailable Second - Line/MS UASL, 10 10


Unavailable Second - Section/RS UASMS
UASS,
UASRS

Failure Count - Line/MS FC-L, 1 1


FCMS

76.MTFP50/30, Rev B January 2018 Page 30-1207


22. Retrieve Commands TL1 Command Reference Manual

Table 22.101 Default Threshold for OC48 Signal


Threshold Threshold
Monitored Parameter Montype
15-Minute 1-Day
Coding Violation - Section CVS, 2240 215040
Background Block Error - RS BBERS

Errored Second - Section/RS ESS, 25 250


ESSRS

Severely Errored Seconds - Section/RS SESS, 4 40


SESSRS

Severely Errored Frame Second - Section SEFSS, 2 8


Out of Frame Seconds - RS OFSRS

Loss of Signal Seconds LOSS 2 8


Coding Violation - Line CVL, 2208 212640
Background Block Error - MS BBEMS

Errored Second - Line/MS ESL, 25 250


ESMS

Severely Errored Seconds - Line/MS SESL, 4 40


SESMS

Unavailable Second - Line/MS UASL, 10 10


Unavailable Second - Section/RS UASMS,
UASS,
UASRS

Failure Count - Line/MS FC-L, 1 1


FCMS

Table 22.102 Default Threshold for OC192/STM64 Signal


Threshold Threshold
Monitored Parameter Montype
15-Minute 1-Day
Coding Violation - Section CVS, 8960 860160
Background Block Error - RS BBERS

Errored Second - Section/RS ESS, 25 250


ESSRS

Severely Errored Seconds - Section/RS SESS, 4 40


SESSRS

Severely Errored Frame Second - Section SEFSS, 2 8


Out of Frame Seconds - RS OFSRS

Loss of Signal Seconds LOSS 2 8


Coding Violation - Line CVL, 8832 850560
Background Block Error - MS BBEMS

Errored Second - Line/MS ESL, 25 250


ESMS

Page 30-1208 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.102 Default Threshold for OC192/STM64 Signal (Continued)


Threshold Threshold
Monitored Parameter Montype
15-Minute 1-Day
Severely Errored Seconds - Line/MS SESL, 4 40
SESMS

Unavailable Second - Line/ UASL, 10 10


Unavailable Second - Section/RS UASMS,
UASS,
UASRS

Failure Count - Line/MS FC-L, 1 1


FCMS

Table 22.103 Default Thresholds for STS1/STS3C/STS12C/STS48C/192C


Threshold Threshold
Monitored Parameter Montype
15-Minute 1-Day

Coding Violation - Path, STS1 CVP 15 125


Coding Violation - Path, STS3C CVP 25 250
Coding Violation - Path, STS12C CVP 75 750
Coding Violation - Path, STS48C CVP 320 3200
Coding Violation - Path, STS192C a CVP 20 200
Errored Second - Path, STS1 ESP 12 100
Errored Second - Path, STS3C ESP 20 200
Errored Second - Path, STS12C ESP 60 600
Errored Second - Path, STS48C ESP 250 2500
Errored Second - Path, STS192C a ESP 16 160
Severely Errored Seconds - Path (All STS) SESP 3 7
Unavailable Second - Path (All STS) UASP 10 10
Pointer Justification Count Seconds - Generate PJCSPGEN 0 0
(All STS)

Pointer Justification Count Seconds - Detect PJCSPDET, 0 0


(All STS)

Pointer Justification Count Seconds - Difference PJCDIFFP 0 0


(All STS)

Failure Count - Path FCP 1 1


-12
a - The STS192C values assume the path is carried over a facility with a BER of 1x10 (that is, over
OC192).

76.MTFP50/30, Rev B January 2018 Page 30-1209


22. Retrieve Commands TL1 Command Reference Manual

Table 22.104 BIP Errors required to Trigger SESS or SESL


Rate Section BIP Errors for SESS Line BIP Errors for SESL
OC3 155 154

OC12 616 615

OC48 2392 2459

OC192 8554 9835

Table 22.105 Default Thresholds for Data Signals (GBEP, TGLAN, FGE, HGE)
Threshold Threshold

Monitored Parameter Montype 15-Minute 1-Day


Symbol Error During SE 113 10800
Carrier

Symbol Error During SE 452 43200


Carrier (for FGE)

Symbol Error During SE 1130 108000


Carrier (for HGE)

Loss of Signal Seconds LOSS 2 8

Table 22.106 Default Thresholds for G.709 ODU/OTU Signals


Threshold Threshold

Monitored Parameter Montype 15-Minute 1-Day


Block Error - Forward Error BE-FEC 29993 2879342
Correction (applies to (each unit represents (each unit represents
OTU1) 8000 errors) 8000 errors)
Block Error - Forward Error BE-FEC 120479 11565963
Correction (applies to (each unit represents (each unit represents
OTU2, applies to OCH-P 8000 errors) 8000 errors)
on 10G Transponders)

Block Error - Forward Error BE-FEC 124827 11983386


Correction (applies to (each unit represents (each unit represents
OTU2(OTU2e), applies to 8000 errors) 8000 errors)
OCH-P(OTU2e) on 10G
Transponders)

Block Error - Forward Error BE-FEC 1085211000000 104180256000000


Correction (applies to (each unit represents 1 (each unit represents 1
OCH-P on 100G error) error)
Transponder)

Block Error - Forward Error BE-FEC 10062897621 966038171630


Correction (applies to (each unit represents 1 (each unit represents 1
OTU4) error) error)

Page 30-1210 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.106 Default Thresholds for G.709 ODU/OTU Signals (Continued)


Threshold Threshold

Monitored Parameter Montype 15-Minute 1-Day


Block Error - Forward Error BE-FEC 1085211000000 104180256000000
Correction (applies to (each unit represents 1 (each unit represents 1
OCH-OS on 100G with error) error)
15% SFEC, 120.579 Gb/s)

Block Error - Forward Error BE-FEC 1236194046360 118674628450560


Correction (applies to (each unit represents 1 (each unit represents 1
OCH-OS on 100G with error) error)
25% SFEC, 137.355 Gb/s)

Block Error - Forward Error BE-FEC 2472388092720 237349256901120


Correction (applies to (each unit represents 1 (each unit represents 1
OCH-OS on 2X150G with error) error)
25% SFEC, 206.035 Gb/s)

Block Error - Forward Error BE-FEC 2472388092720 237349256901120


Correction (applies to (each unit represents 1 (each unit represents 1
OCH-OS on 200G with error) error)
25% SFEC, 273.328 Gb/s)

Uncorrectable Block UBE-FEC 875 84000


Errors, Forward Error
Correction (applies to
OCH-P, OTU1, OTU2)

Uncorrectable Block UBE-FEC 875 84000


Errors, Forward Error
Correction (applies to
OCH-OS on 100G with
15% SFEC, 120.579 Gb/s)

Uncorrectable Block UBE-FEC 875 84000


Errors, Forward Error
Correction (applies to
OCH-OS on 100G with
25% SFEC, 137.355 Gb/s)

Uncorrectable Block UBE-FEC 875 84000


Errors, Forward Error
Correction (applies to
OCH-OS on 2X150G with
25% SFEC, 206.035 Gb/s)

Uncorrectable Block UBE-FEC 875 84000


Errors, Forward Error
Correction (applies to
OCH-OS on 200G with
25% SFEC, 273.328 Gb/s)

Bit Error Rate, before BER-FEC-HT 1.0E-2 1.0E-2


Forward Error Correction (High Threshold) (High Threshold)
(applies to OCH-P on
OSM2C)

76.MTFP50/30, Rev B January 2018 Page 30-1211


22. Retrieve Commands TL1 Command Reference Manual

Table 22.106 Default Thresholds for G.709 ODU/OTU Signals (Continued)


Threshold Threshold

Monitored Parameter Montype 15-Minute 1-Day


Bit Error Rate, before BER-FEC-HT 1.0E-2 1.0E-2
Forward Error Correction (High Threshold) (High Threshold)
(applies to OCH-OS on
100G with 15% SFEC,
120.579 Gb/s)

Bit Error Rate, before BER-FEC-HT 1.0E-3 1.0E-3


Forward Error Correction (High Threshold) (High Threshold)
(applies to OCH-OS on
100G with 25% SFEC,
137.355 Gb/s)

Bit Error Rate, before BER-FEC-HT 2.0E-3 2.0E-3


Forward Error Correction (High Threshold) (High Threshold)
(applies to OCH-OS on
2X150G with 25% SFEC,
206.035 Gb/s)

Bit Error Rate, before BER-FEC-HT 8.0E-3 8.0E-3


Forward Error Correction (High Threshold) (High Threshold)
(applies to OCH-OS on
200G with 25% SFEC,
273.328 Gb/s)

Code Violations/Error CV-OTU (SONET) 735 70575


blocks - OTU (applies to EB-OTU (SDH)
OTU1 on OSM-1S)

Code Violations/Error CV-OTU (SONET) 738 70870


blocks - OTU (applies to EB-OTU (SDH)
OTU2 on OSM-2S/OSM-
4S)

Code Violations/Error CV-OTU (SONET) 765 73428


blocks - OTU (applies to EB-OTU (SDH)
OTU2e on OSM-2S/OSM-
4S)

Code Violations/Error CV-OTU (SONET) 771 73992


blocks - OTU (applies to EB-OTU (SDH)
OTU4)

Code Violations/Error CV-OTU (SONET) 1943 186541


blocks - OTU (applies to EB-OTU (SDH)
OTU4 - 25% FEC, 137.355
Gb/s)

Code Violations/Error CV-OTU (SONET) 3886 373081


blocks - OTU (applies to EB-OTU (SDH)
OTUC2)

Code Violations/Error CV-OTU (SONET) 5829 559622


blocks - OTU (applies to EB-OTU (SDH)
OTUC3)

Errored Seconds - OTUk/ ES-OTU 25 250


OTUC2/OTUC3

Page 30-1212 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.106 Default Thresholds for G.709 ODU/OTU Signals (Continued)


Threshold Threshold

Monitored Parameter Montype 15-Minute 1-Day


Severely Errored Seconds SES-OTU 4 40
- OTUk/OTUC2/OTUC3

Unavailable Seconds - UAS-OTU 10 10


OTUk/OTUC2/OTUC3

Errored Blocks - ODUF EB-ODU 0.00025 (%) 0.00025 (%)


Errored Blocks - ODU0 EB-ODU 92 8786
Errored Blocks - ODU1 EB-ODU 735 70575
Errored Blocks - ODU2 EB-ODU 738 70870
Errored Blocks - ODU2e EB-ODU 765 73428
Errored Blocks - ODU4 EB-ODU 771 73992
Errored Seconds - ODUk ES-ODU 25 250
Severely Errored Seconds SES-ODU 4 40
- ODUk

Unavailable Seconds - UAS-ODU 10 10


ODUk

Loss of Signal Seconds LOSS 2 8


(applies to OTUk only)

Loss of Signal Seconds LOSS 2 8


(applies to OCH-OS only)

Delay measurement - DELAY-ODU-LT 0 0


ODU - Low Threshold
Delay measurement - DELAY-ODU-HT 2147483647 2147483647
ODU - High Threshold
Differential Group Delay DGD-HT +71 +71
- High Threshold
Differential Group Delay - DGD-HT 101 101
High Threshold (applies to
OCH-OS)

Chromatic Dispersion - CD-LT -40000 -40000


Low Threshold
Chromatic Dispersion - CD-LT -40000 -40000
Low Threshold (applies to
OCH-OS)

Chromatic Dispersion - CD-HT +40000 +40000


High Threshold
Chromatic Dispersion - CD-HT +40000 +40000
High Threshold (applies to
OCH-OS)

76.MTFP50/30, Rev B January 2018 Page 30-1213


22. Retrieve Commands TL1 Command Reference Manual

Table 22.106 Default Thresholds for G.709 ODU/OTU Signals (Continued)


Threshold Threshold

Monitored Parameter Montype 15-Minute 1-Day

Optical Signal to Noise OSNR-LT 0 0


Ratio - Low Threshold
Optical Signal to Noise OSNR-LT 0 0
Ratio - Low Threshold
(applies to OCH-OS)

Table 22.107 Default Thresholds for Optical Power Levels


Monitored Point Low Threshold High Threshold

Monitored Parameter Montype 15-Minute/1-Day 15-Minute/1-Day


OSC OPR OSC on OADMRS/ -18.0 dBm +1.0 dBm
Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=LOW,
and OTSMODE= 7100

OSC OPR OSC on OADMRS/ -32.0 dBm -12.0 dBm


Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=HIGH,
and OTSMODE= 7100

OSC OPR OSC on OADMRS/ -20.0 dBm +1.0 dBm


Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=LOW,
and OTSMODE= MTERA
or HIT7300

OSC OPR OSC on OADMRS/ -35.0 dBm -12.0 dBm


Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=HIGH,
and OTSMODE= MTERA
or HIT7300

OCH-L (wavelength) OPR OCH-L on OADMRS/ -18.0 dBm +1.0 dBm


Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=LOW,
and OTSMODE= 7100

OCH-L (wavelength) OPR OCH-Lon OADMRS/ -34.0 dBm -12.0 dBm


Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=HIGH,
and OTSMODE= 7100

OCH-L (wavelength) OPR OCH-L on OADMRS/ -18.0 dBm -11.0 dBm


Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=LOW,
and OTSMODE= MTERA
or HIT7300

OCH-L (wavelength) OPR OCH-L on OADMRS/ -37.0 dBm -12.0 dBm


Optical Power Receive OADMRS9 for
DWDM Input OPGAINRANGE=HIGH,
and OTSMODE= MTERA
or HIT7300

Page 30-1214 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.107 Default Thresholds for Optical Power Levels (Continued)


Monitored Point Low Threshold High Threshold

Monitored Parameter Montype 15-Minute/1-Day 15-Minute/1-Day


OCH-L (wavelength) OPT OCH-L on OADMRS/ -6.0dB +6.0dB
Optical Power Transmit OADMRS9 (offset to target (offset to target
DWDM Output level) level)
OCH-P OPR OCH-P on 100G line side -18 dBm 0 dBm
Optical Power Receive interface, OSM-2C
100G Line side Interface,
OSM-2C

OCH-P OPR OCH-P on 10G line side -18 dBm -5.0 dBm
Optical Power Receive interface
10G Line side Interface

OCH-OS OPR OCH-OS on 100G line side -18 dBm +15 dBm
Optical Power Receive interface, OSM-4C
100G Line side Interface,
OSM-4C

OCH-OS OPR OCH-OS on 100G/200G/ -18 dBm +15 dBm


Optical Power Receive 2X150G line side interface,
100G/200G/2X150G Line OSM-4F
side Interface, OSM-4F

Table 22.108 Default Thresholds and Range for Ethernet PM


Threshold Threshold

Monitored Parameter Montype 15-Minute 1-Day


DropEvents * DROP 0 0

Pkts PKT 0 0

BroadcastPkts BCPKT 0 0

MulticastPkts MCPKT 0 0

CRCAlignErrors CRCAE 0 0

UndersizePkts USPKT 0 0

OversizePkts OSPKT 0 0

Fragments FRAG 0 0

Jabbers JABR 0 0

Utilization UTIL 0 0

Note:
* Per RFC 2819, the DropEvents statistic is a count of frames that are dropped due to a lack of resources and does not
include frames dropped due to errors.

Note: When the default threshold level value is set to 0 for a counter montype,
then no automatic message (TCA) is generated for this montype.

76.MTFP50/30, Rev B January 2018 Page 30-1215


22. Retrieve Commands TL1 Command Reference Manual

Command Format
RTRV-PM-{<fac_type>|ALL}:[tid]:[{<fac_aid>|ALL}]:ctag::
[<montype>],[<monlev>],[<locn>],[<dirn>],[<tmper>],[<mondat>] [,<montim>];

Proper System Response when the PM Mode is set to ON, but there are currently no register values:
<header>

M <ctag> COMPLD

Proper System Response when PM mode is set to ON, and there are values:
<header>

M <ctag> COMPLD

"<fac_aid>,<aidtype>:<montype>,<monval>,<vldty>,<locn>,<dirn>,<tmper>,
<mondat>,<montim>"
.
.
"<fac_aid>,<aidtype>:<montype>,<monval>,<vldty>,<locn>,<dirn>,<tmper>,
<mondat>,<montim>"
;

Proper System Response when the PM mode is currently OFF and has remained OFF for the entire collection period
(specified with the SET-PMMODE-{X} command):
<header>

M <ctag> COMPLD

"<fac_aid>,<aidtype>:<montype>,NA,NA,NEND,,< tmper>, <mondat>,<montim>"


.
.
"<fac_aid>,<aidtype>:<montype>,NA,NA,NEND,, <tmper>, <mondat>,<montim>"
;

Parameters
Refer to AID restrictions table in Section 2 for specific information on AID range restrictions.

Page 30-1216 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.109 RTRV-PM-{X} Parameters


Parameter Value(s) Definition
fac_aid FGE-20-[1-16]-[1-2] EntityID-ShelfID-SlotID-PortID[-ODU4TribPort]
GBEP-20-[1-16]-[1-32]
HGE-20-[1-16]-[1-5]
OC12-20-[1-16]-[1-32]
OC192-20-[1-16]-[1-40], OC192-20-[1-
16]-99-[1-6]
OC3-20-[1-16]-[1-32]
OC48-20-[1-16]-[1-32], OC48-20-[1-
16]-99-[7-30]
OCH-20-[10-16,1-7]-[1-3]-[1-88],
OCH-20-[1-16]-[1-2]-[19135-19610],
OCH-20-[10-16,1-7]-[1-20], OCH-20-
[10-16,1-7]-[1-3]-[2-13], OCH-[50-58]-
[2-4,6-8]-[3-6,9-12]
OCH-L-20-[10-16,1-7]-21-[1-96],OCH-
L-20-[1-16]-1-[1-96]
OCH-OS-20-[1-16]-[1-4]
OCH-P-20-[1-16]-[1-40]
ODU0-20-[1-16]-[1-32], ODU0-20-[1-
16]-[1-40]-[1-80], ODU0-20-[1-16]-[1-
5]-[B,C][1-80]-[1-32], ODU0-20-[1-16]-
[1-2]-[D][1-3]-[B,C][1-80]-[1-32],
ODU0-20-[1-16]-[1-2]-[D][1-3]-[1-80]
ODU1-20-[1-16]-[1-32], ODU1-20-[1-
16]-[1-40]-[1-80], ODU1-20-[1-16]-[1-
5]-[B,C][1-80]-[1-16], ODU1-[20]-[1-
16]-99-[7-30], ODU1-20-[1-16]-[1-2]-
[D][1-3]-[B,C][1-80]-[1-16]
ODU2-20-[1-16]-[1-40], ODU2-20-[1-
16]-[1-20]-[1-80], ODU2-20-[1-16]-[1-
5]-C[1-80]-[1-4], ODU2-[20]-[1-16]-99-
[1-6], ODU2-20-[1-16]-[1-2]-[D][1-3]-
C[1-80]-[1-4], ODU2-20-[1-16]-[1-2]-
[D][1-3]-[1-80]
ODU2E-20-[1-16]-[1-4], ODU2E-20-[1-
16]-[1-5]-[1-80], ODU2E-20-[1-16]-[1-
5]-C[1-80]-[1-32], ODU2E-20-[1-16]-
[1-2]-[D][1-3]-C[1-80]-[1-32], ODU2E-
20-[1-16]-[1-2]-[D][1-3]-[1-80]
ODU3-20-[1-16]-[1-5]-[1-80], ODU3-
20-[1-16]-[1-2], ODU3-20-[1-16]-[1-2]-
[D][1-3]-[1-80]
ODU4-20-[1-16]-[1-5], ODU4-20-[1-
16]-[1-2]-[1-3]
ODUF-20-[1-16]-[1-40]-[1-80], ODUF-
20-[1-16]-[1-20]-[B,C][1-80]-[1-32],
ODUF-20-[1-16]-[1-2]-[D][1-3]-[B,C][1-
80]-[1-32]
OMS-20-[10-16,1-7]-21,OMS-20-[1-
16]-1
OSC-20-[10-16,1-7]-21,OSC-20-[1-
16]-1
OTU1-20-[1-16]-[1-32]
OTU2-20-[1-16]-[1-40]
OTU4-20-[1-16]-[1-5]
OTUC2-20-[1-16]-[1-2]

76.MTFP50/30, Rev B January 2018 Page 30-1217


22. Retrieve Commands TL1 Command Reference Manual

Table 22.109 RTRV-PM-{X} Parameters (Continued)


Parameter Value(s) Definition
fac_aid (cont.) STS1-20-[1-16]-[1-30]-[1-192], STS1- EntityID-ShelfID-SlotID-PortID[-ODU4TribPort]
20-[1-16]-99-[1-30]-[1-192]
STS12C-20-[1-16]-[1-30]-[181,-
,37,25,13,1], STS12C-20-[1-16]-[1-
30]-99-[181,-,37,25,13,1]
STS192C-20-[1-16]-[1-6]-1, STS192C-
20-[1-16]-99-[1-6]-1
STS3C-20-[1-16]-[1-30]-[190,-
,13,10,7,4,1], STS3C-20-[1-16]-99-[1-
30]-[190,-,13,10,7,4,1]
STS48C-20-[1-16]-[1-30]-
[145,97,49,1], STS48C-20-[1-16]-99-
[1-30]-[145,97,49,1]
TGLAN-20-[1-16]-[1-40]

montype x,x-C,x-F Specifies the type of performance monitoring for the specified
entity.
- x: To be used to specify current value for <montype> x.
- x-C: To be used to specify highest value for gauge <montype>
x. C=Ceiling.
- x-F: To be used to specify lowest value for gauge <montype>
x. F=Floor.

monlev LEV-DIRN. Where: LEV is a value Specifies the level at which the performance monitoring type is
within the range supported for each reported:
montype. DIRN is either UP or DN. - UP means that values equal to or greater than LEV are
reported.
- DN means that values less than LEV are reported.
The system defaults to -60-UP for OPR and OPT montypes.
The system defaults to 1-UP for all counters montypes. This
means that all counter with value=0 (with no accumulation) does
not be shown when default <monlev> value is selected.

locn NEND specifies the location of an event/occurrence in the system:


FEND - Enter NEND to specify a near-end location.
- Enter FEND to specify a far-end location

dirn BTH Specifies the direction of an event/occurrence in the system:


TDTC - BTH specifies both applicable directions: one type of TDTC
TDTN and one type of TDTN.
RCV - TDTC specifies Transmit direction toward Customer.
TRMT - TDTN specifies Transmit direction toward DWDM network.
NA - RCV specifies Receive direction.
- TRMT specifies Transmit direction.
- NA indicates Not Applicable (valid in the response only).

tmper 15-MIN Specifies the time-period increments during which PM data are
1-DAY collected.
- Enter 15-MIN to specify 15-minute increments.
- Enter 1-DAY to specify daily increments.
The system defaults to 15-minute increments.

mondat MOY-DOM format:(1)MOY = 1 - Specifies the one day index during which PM data is collected.
12.(2)DOM = 1 - 31. The system defaults to the current date.

montim x-y format:(1). x is any number in the Specifies the beginning of the 15-minute performance
range 0-23. (2). y is one of the monitoring collection time period.
following 15-minute increments: 00, The system defaults to the current 15-minute collection time
15, 30, or 45. period.

Page 30-1218 January 2018 76.MTFP50/30, Rev B


TL1 Command Reference Manual 22. Retrieve Commands

Table 22.109 RTRV-PM-{X} Parameters (Continued)


Parameter Value(s) Definition
aidtype GBEP The access identifier contains one or more simple or compound
FGE parameters that uniquely identifies the selected entity within the
HGE NE.
OC3
OC12
OC48
OC192
OCH
ODUF
ODU0
ODU1
ODU2
ODU2E
ODU3
ODU4
OMS
OTU1
OTU2
OTU4
OTUC2
OTUC3
OSC
STM1
STM4
STM16
STM64
TGLAN

monval (1)-60.0 to +60.0, LT+12.0, GT+20.0, This value specifies the value of a performance monitoring
1.9E-2 to 2.3E-11, -40000 to +40000 counter or gauge.
for gauges. (2)0 to - NA specifies that the parameter value is not available at the
18446744073709551615 for counters. time of retrieval.
(3)NA

vldty COMPL Indicates whether or not a performance monitoring value is valid


NA - COMPL indicates that performance monitoring data are
PRTL accumulated.
- NA indicates that performance monitoring data are not
available.
- PRTL indicates that performance monitoring data are
accumulated during a partial time period.

Example 1
RTRV-PM-OTU2::OTU2-20-1-2:ctag::,,,,,,;

Possible System Response


CORIANT 14-11-04 14:49:47
M ctag COMPLD
"OTU2-20-1-2,OTU2:LOSS,NA,NA,NEND,TDTN,15-MIN,11-04,14-45"
"OTU2-20-1-2,OTU2:BE-FEC,NA,NA,NEND,TDTN,15-MIN,11-04,14-45"
"OTU2-20-1-2,OTU2:UBE-FEC,NA,NA,NEND,TDTN,15-MIN,11-04,14-45"
"OTU2-20-1-2,OTU2:CV-OTU,NA,NA,NEND,TDTN,15-MIN,11-04,14-45"
"OTU2-20-1-2,OTU2:ES-OTU,NA,NA,NEND,TDTN,15-MIN,11-04,14-45"

76.MTFP50/30, Rev B January 2018 Page 30-1219


22. Retrieve Commands TL1 Command Reference Manual

"OTU2-20-1-2,OTU2:SES-OTU,NA,NA,NEND,TDTN,15-MIN,11-04,14-45"
"OTU2-20-1-2,OTU2:UAS-OTU,NA,NA,NEND,TDTN,15-MIN,11-04,14-45"
;

Example 2
RTRV-PM-OTUC2::OTUC2-20-1-1:ctag::,-100-UP;

Possible System Response


CORIANT 17-05-12 11:47:18
M ctag COMPLD
"OTUC2-20-1-1,OTUC2:CV-OTU,0,PRTL,NEND,TDTC,15-MIN,05-12,11-45"
"OTUC2-20-1-1,OTUC2:ES-OTU,0,PRTL,NEND,TDTC,15-MIN,05-12,11-45"
"OTUC2-20-1-1,OTUC2:SES-OTU,0,PRTL,NEND,TDTC,15-MIN,05-12,11-45"
"OTUC2-20-1-1,OTUC2:UAS-OTU,1,PRTL,NEND,TDTC,15-MIN,05-12,11-45"
"OTUC2-20-1-1,OTUC2:CV-OTU-FE,0,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
"OTUC2-20-1-1,OTUC2:ES-OTU-FE,0,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
"OTUC2-20-1-1,OTUC2:SES-OTU-FE,0,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
"OTUC2-20-1-1,OTUC2:UAS-OTU-FE,1,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
;

Example 3
RTRV-PM-ODU4::ODU4-20-1-1:ctag::,-100-UP,FEND;

Possible System Response


CORIANT 17-05-12 11:47:18
M ctag COMPLD
"ODU4-20-1-1,ODU4:EB-ODU-FE,0,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
"ODU4-20-1-1,ODU4:ES-ODU-FE,0,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
"ODU4-20-1-1,ODU4:SES-ODU-FE,0,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
"ODU4-20-1-1,ODU4:UAS-ODU-FE,1,PRTL,FEND,TDTC,15-MIN,05-12,11-45"
;

Error Messages
Error codes are defined and explained in Section 3, Error Codes for TL1 Output Responses.

Related Commands
INH-PMREPT-{X}
RTRV-PMMODE-{X}
SET-PMMODE-{X}

Page 30-1220 January 2018 76.MTFP50/30, Rev B

You might also like