Professional Documents
Culture Documents
Name of the
Title Authors YoP Main conclusion
No. journal
Base iso-lation was found
to be more effective for
Seismic Ayman A. slender tanks in
Ain Shams response of Seleemah, comparison with broad
1 Engineering base isolated Mohamed 2011 tanks.
Journal liquid storage El- Note: Nevertheless, the clear
ground tanks Sharkawy height over the liquid surface
should be increased especially in
slender tanks
In the present study, it is
shown that the seismic
Seismic fragility of tank structure
Performance largely depends on soil
Hitesh
of Base- stiffness along with staging
Kumar,
Isolated stiffness.
American S.M. ASCE
Elevated Moreover, regardless of
2 Society of Civil , and 2020
Liquid Storage the configuration, the
Engineers Sandip
Tanks isolation system is
Kumar
Considering observed to be effective in
Saha
Soil–Structure enhancing the seismic
Interaction performance of the
elevated liquid storage
tanks.
3 Journal of Earthquake M.K. 2003 Comparative performance of
Constructional response of Shrimali, elevated liquid storage tanks by
Steel Research isolated R.S. Jangid putting the base isolation system
elevated at top and bottom of the
liquid supporting tower is investigated
storage steel using real earthquake motions. The
tank earthquake response of isolated
tanks is compared with non-
isolated tanks to measure the
effectiveness of the isolation. In
addition, a simplified decoupled
analysis is proposed to investigate
the response of isolated elevated
liquid storage tanks. The following
conclusions are drawn from the
trends of the results of isolated
elevated liquid storage tank
Volume 2, Issue 1,
2011,
Pages 33-42,
ISSN 2090-4479,
https://doi.org/10.1016/j.asej.2011.05.001.
(https://www.sciencedirect.com/science/article/pii/S2090447911000104)
Abstract: In this paper, the seismic responses of base-isolated broad and slender cylindrical liquid
storage ground tanks are investigated. Three types of isolation systems are considered. The seismic
responses are compared with the corresponding responses of non-isolated tanks. Moreover, a
parametric study was conducted to evaluate the effect of tank aspect ratio, isolation period, and
friction coefficient of the FPS system on key responses of the tank. It was found that, base isolation is
quite effective in reducing the earthquake response of ground liquid storage tanks. Generally
speaking, 50–90% reductions in both base shear and impulsive displacement responses were
observed. The convective displacement was observed to be 20–70% higher than that associated with
fixed base tanks leading to an essential need of increasing the clear height above the liquid surface.
Base isolation was found to be more effective for slender tanks in comparison with broad tanks.
Keywords: Ground liquid storage tanks; Seismic isolation systems; Aspect ratio; Isolation period;
Broad; Slender
2. Kumar, Hitesh & Saha, Sandip. (2021). Seismic Performance of Base Isolated Elevated Liquid
Storage Tanks Considering Soil-Structure Interaction. Practice Periodical on Structural Design
and Construction. 26. 10.1061/(ASCE)SC.1943-5576.0000545.
3. M.K. Shrimali, R.S. Jangid,
2003,
Pages 1267-1288,
ISSN 0143-974X,
https://doi.org/10.1016/S0143-974X(03)00066-X.
(https://www.sciencedirect.com/science/article/pii/S0143974X0300066X)
Abstract: Earthquake response of elevated liquid storage steel tanks isolated by the linear
elastomeric bearings is investigated under real earthquake ground motion. Two types of isolated
tank models are considered in which the bearings are placed at the base and top of the steel tower
structure. The continuous liquid mass of the tank is modelled as lumped masses known as sloshing
mass, impulsive mass and rigid mass. The corresponding stiffness constants associated with these
lumped masses have been worked out depending upon the properties of the tank wall and liquid
mass. The mass of steel tower structure is lumped equally at top and bottom. Since the damping
matrix of the isolated tank system is non-classical in nature, the seismic response is obtained by the
Newmark’s step-by-step method. The response of two types of tanks, namely slender and broad
tanks, is obtained and a parametric study is carried out to study the effects of important system
parameters on the effectiveness of seismic isolation. The various important parameters considered
are the tank aspect ratio, the time period of tower structure, damping and the time period of
isolation system. It has been shown that the earthquake response of the isolated tank is significantly
reduced. Further, it is also observed that the isolation is more effective for the tank with stiff steel
tower structure in comparison to flexible towers. In addition, a simplified analysis is also presented
to evaluate the response of the elevated steel tanks using two-degrees-of-freedom model and two
single-degree-of-freedom models. It is observed that the proposed analysis predicts the seismic
response of elevated steel tanks accurately with significantly less computational efforts.
Keywords: Elevated steel tanks; Elastomeric bearings; Isolation; Earthquake; Liquid container;
Effectiveness; System parameters
4.