DIFFERENCE BETWEEN ADJACENT ZONES) SHALL BE INSTALLED IN 2.6W LED RECESS MOUNTED EXIT LIGHT
2Cx4sq.mm FP200 DC CABLE MAINTAINED TYPE-IP40(F.O.H AREAS)
THIS BUILDING IN ACCORDANCE WITH UAE FLS CODE AND OTHER MAKE/ MODEL: EATON/ GUIDE LED 11024
INTERNATIONAL CODES AND STANDARDS. 1.2 W LED ABOVE DOOR/ WALL MOUNTED EXIT LIGHT
UN-SWITCHED REFERENCE SUPPLY
14. ALL INTERIORS FINISHING MATERIAL SHALL BE PROVIDED AS MAINTAINED TYPE-IP65(B.O.H AREAS)
FROM LOCAL DB's FOR SENSING POWER (UAE FIRE AND LIFE SAFETY CODE AND NFPA 101). MAKE/ MODEL: EATON/ SAFELITE
FAILURE(TYP.) 2x1Cx1.5sq.mm PVC WIRES
15. FIRE PUMP AND FIRE WATER TANK SHALL BE LISTED AND CENTRAL BATTERY MAIN PANEL
TESTED AND INSTALLED ACCORDING TO CIVIL DEFENSE
REQUIREMENT AND INTERNATIONAL STANDARDS. AND ALL PUMP CENTRAL BATTERY SUB PANEL
CAPACITY THAT LESS THAN 350 GPM SHALL BE ONLY REGISTER
2Cx2.5mm.sq. FP200 CABLE
1 LIGHTING DB WITH ABUDHABI QUALITY AND CONFORMITY COUNCIL WITHOUT
FDB-BLD2A-L1-L1 ANY REGISTRATION AND APPROVAL FROM ANY REGISTER ABBREVIATIONS
1
LABORATORY.
DLS-SUB-CIRCUIT T/A TO ABOVE T/B TO BELOW
MONITORING MODULE DLS 16. EMERGENCY POWER SYSTEM SHALL BE INSTALLED IN THIS
BUILDING IN ACCORDANCE TO THE RELEVANT NFPA CODE. F/A FROM ABOVE F/B FROM BELOW
17. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED
WALLS SHALL BE PROTECTED BY APPROVED FIRE STOP SYSTEM
AND MATERIALS, INSTALLED AND TESTED IN ACCORDANCE WITH REFERENCE NO:
1
LOCATION:ELEC.ROOM ASTM E 814 OR UL 1479. IFC 256282-BLD2A-SCH-ELE-0060-2
1ST FLOOR (2A-FF-03)
230VAC 18. ALL MEANS OF AGGRESS COMPONENTS DETAILS AND
R8/ESMDB-BLD2A-L0-1A AE 1156-4TCD-PROSW-ELE-SPE-0001
DIMENSIONS SHALL BE PROVIDED AND CONSTRUCTED ACCORDING SPECIFICATION
31.SECTION 26 52 00
1 TO (UAE FIRE AND LIFE SAFETY CODE AND NFPA 101 AND 5000).
2Cx4sq.mm FP200 DC CABLE 19.CONSULTANT AND CONTRACTOR SHALL COMPLY WITH
FIRST FLOOR UAE FIRE AND LIFE SAFETY CODE CHAPTER 12 IN TERMS OF
REQUIREMENTS OF BUILDING UNDER CONSTRUCTION.
UN-SWITCHED REFERENCE SUPPLY 20. EMERGENCY ACTION PLAN SHALL BE IMPLEMENTING IN
FROM LOCAL DB's FOR SENSING POWER
FAILURE(TYP.) THESE BUILDINGS ACCORDING TO UAE FIRE AND LIFE SAFETY CODE.
21.ALL DECORATION DESIGN AND MATERIALS AND ALL SERVICE
SYSTEMS IN THIS BUILDING SHALL NOT OBSTRUCT ALL
FIRE SAFETY SYSTEM ESPECIALLY SPRINKLER SYSTEM
NETWORK CABLE BELDEN 5341FE
1
LIGHTING DB
FDB-B2-L0-L3
1
LIGHTING DB
FDB-B2-L0-L1
2x1Cx1.5sq.mm PVC WIRES
1
DLS-SUB-CIRCUIT
DLS
MONITORING MODULE
ZB-S/10C
1 CBMP-BLD02
PANEL
PC WITH GRAPHIC
1
LOCATION: BUILDING.01
SEC. CONTROL ROOM (01.GF.09)
LOCATION:- ELEC.ROOM
GROUND FLOOR 2A.GF.39
BUILDING-02
FZ - LLC
P.O.Box: 46625
Tel: 02-4067888, Fax: 02-5512955
Abu Dhabi, U.A.E
E-mail : gisco@giscoauh.ae,
BUILDING 02A
SCHEMATIC DIAGRAM
CENTRAL BATTERY SYSTEM
AJ-420-0-EN-SEE-02-GIS-0001