You are on page 1of 3

DISTR.

ELP1 230VAC –BRIDGE DECK


Drawing no: 080-872-131 Circ. Breaker: Merlin Gerin
Rev: - Type: C60H
Date/Drawn: 11.01.10 KV Supply from: ESB GD02-Q01
2
Customer: MANDAL BÅTSERVICE IRAN Supply cable: MPRXCX 3x16mm
Yard no: 80 Pprinted 29.03.2010 09:33 Cabinet: 600x400x200

Circuit list Ph Load Breaker Cable

<kW> <A> <A> mm2 Type


1 EM.LIGHT INSIDE AND OUTSIDE BRIDGE 1 10C 2X1,5 MPRXCX
2 FLOODLIGHT LIFERAFT SB 1 1500 10C 2X1,5 MPRXCX
3 EM.FLOODLIGHT PILOT HOUSE TOP AFT 1 800 10C 2X1,5 MPRXCX
EM.LIGHT OUTSIDE ACC. FORECASTLE
4 1 10C 2X1,5 MPRXCX
DECK AND MAIN DECK
EM.LIGHT AFT FORECASTLE DECK AND
5 1 10C 2X1,5 MPRXCX
MAIN DECK
6 EM.LIGHT IN ACC. FORECASTLE DECK 1 10C 2X1,5 MPRXCX
7 FLOODLIGHT LIFERAFT PS 1 1500 10C 2X1,5 MPRXCX
8 SUPPLY CHARGER DC 10 1 16C
9 SPARE 1 16C
10 SPARE 1 16C
11 SPARE 1 16C
12 SPARE 1 16C
13 SPARE 1 16C
14 SPARE 1 16C

PENETRATIONS IN BOTTOM
DISTR. ELP2 230VAC – MAIN DECK
Drawing no: 705-872-132 Circ. Breaker: Merlin Gerin
Rev: - Type: C60H
Date/Drawn: 11.01.10 KV Supply from: ESB GD02-Q02
2
Customer: MANDAL BÅTSERVICE IRAN Supply cable: MPRX 3x16mm
Yard no: 80 Printed 29.03.2010 09:33 Cabinet: 600x400x200

Circuit list EF Ph Load Breaker Cable

<kW> <A> <A> mm2 Type


1 EM.LIGHT IN ACC.MAIN DECK 1 16C 2X1,5 MPRX
2 EM.LIGHT EMERGENCY GEN.ROOM 1 16C 2X1,5 MPRX
3 SPARE 1 16C
4 SPARE 1 16C
EM.LIGHT IN VENT.ROOM, LAUNDRY,
5 1 16C 2X1,5 MPRX
STAIRS FWD AND SPARE AREA TW.DECK
EM.LIGHT IN LABORATORY/STORES PS/SB 2X1,
6 1 16C MPRX
MAIN DECK 5
7 SPARE 1 16C
8 SPARE 1 16C
9 SPARE 1 16C
10 SPARE 1 16C
11 SPARE 1 16C
12 SPARE 1 16C
13 SPARE 1 16C
14 SPARE 1 16C

PENETRATIONS IN TOP
DISTR. ELP3 230VAC – ENGINE CONTROL ROOM
LOWER TWEEN DECK
Drawing no: 705-872-133 Circ. Breaker: Merlin Gerin
Rev: - Type: C60H
Date/Drawn: 11.01.10 KV Supply from: ESB GD02-Q03
Customer: MANDAL BÅTSERVICE IRAN Supply cable: MPRX 3x16 mm2
Yard no: 705 Printed 29.03.2010 09:33 Cabinet: 600x400x200

Circuit list Ph Load Breaker Cable


<kW> <A> <A> mm2 Type
EM.LIGHT IN BOW.THR. ROOM AND STORE
1 1 10C 2X1,5 MPRX
MAIN AND TWEEN DECK FWD
EM.LIGHT IN ENGINE CONTROL ROOM
2 1 10C 2X1,5 MPRX
/ENG.WORKSHOP/MACHINERY STORE
EM.LIGHT IN UPPER ENGINE ROOM
3 /SWITCHBOARD ROOM/HARBOUR 1 10C 2X1,5 MPRX
GEN.ROOM
4 EM.LIGHT IN LOWER ENGINE ROOM 1 10C 2X1,5 MPRX
5 SUPPLY CHARGER BATTERY DC 20 1 16C 2X1,5 MPRX
SUPPLY CHARGER BATTERY HARBOUR
6 1 16C 2X1,5 MPRX
GEN
7 SUPPLY CHARGER BATTERY AUX.GEN.1 1 16C 2X1,5 MPRX
8 SPARE 1 16C
9 SPARE 1 16C
10 SPARE 1 16C
11 SPARE 1 16C
12 SPARE 1 16C
13 SPARE 1 16C
14 SPARE 1 16C

PENETRATIONS IN BOTTOM