1.0 Supply and install access controller for the IT Room 1 no.
as specified, on the secure side and above the false
ceiling where possible,suitable to control 1 access
control reader including power supply unit(s), back-
up battery, 230 V power, control and communications
connections. Supply and installation of the cable
connection to the adjacent CAT6 RJ45 outlet shall be
included.
Access controllers controlling more than 1 door will
be considered subject that the price is all inclusive to
meet the specified requirements.
3.0 Supply and install exit button for protected side of the 1 no.
IT room including cable and pvc conduit to the
access controller.
4.0 Supply and install cable and conduit from the access 1 no.
control reader to the electric door lock of the IT
Room.
5.0 Supply and install conduit only from the future 3 no.
access control reader to the electric door lock.
7.0 Supply and install cable and conduit from the access 1 no.
control reader of the IT Room to the door magnetic
contacts.
8.0 Supply and install conduit only from the future access 3 no.
control reader to the door magnetic contacts.
Page 1
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro
9.0 Supply and install cable from the access controller of 1 no.
the IT Room to the adjacent CAT6 RJ45 outlet of the
IT network of the building in order to connect it to the
host computer.
10.0 Supply and install conduit, wiring and fire alarm 1 Lump sum
interface to open all doors with fire alarm.
11.0 Set, programme, test, commission and certify the 1 Lump sum
Access Control System to MSA EN 50133 (all the
equipment and the whole installation) including the
supply of all software and software licenses. Test the
system also from the host computer.Train the system
users.
14.0 Supply 3 sets of as fitted drawings as prints and one 1 Lump sum
set on compact disk.
Page 2
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro
Page 3
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro
2 loops are designated for the basement floor, 1 for
the MHAS offices and one reserved for the future
extension to the rest of the offices in the basement.
12.0 Supply and install fire resistant cable for the following
interconnections from the main fire alarm panel to:
Page 4
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro
5.0 Supply and install external alarm sounder with strobe 1 no.
and battery back-up.
Page 5
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro
GENERAL ITEMS
12.0 Set, programme, test, commission and certify the 1 Lump sum
Intrusion Detection System and the Panic Alarm
System to MSA EN 50131. Train the system users.
Page 6
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro
Page 7
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro
8.0 Supply for approval 3 sets of working drawings in 1 Lump sum
accordance with the latest architectural layouts and
requirements before the order of materials and
before the start of installation works.
Page 8
Rate (incl. Amount (incl.
Item Description Qty Unit
of VAT) of VAT)
Euro Euro