Energy Efficiency Certificate

Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD350A-004G/5R5P-4 Nominal current :9.5A
Nominal voltage : AC 3PH 380V Nominal apparent power :6.2kVA
Nominal power :4kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 6W
Relative
Torque / %
128W 133W 142W
100 2.05% 2.14% 2.28%
92.85% 95.99% 97.38%

Losses
87W 89W 88W Relative losses
50 1.40% 1.43% 1.41% Drive Efficiency
91.91% 95.65% 97.40%

70W 71W 64W


25 1.13% 1.14% 1.03%
90.93% 95.20% 97.31%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
616W 709W 932W
100 15.4% 17.7% 23.3%

Losses
50 303W 381W 496W Relative losses
7.5% 9.5% 12.4%

25 222W 295W
5.5% 7.3%

0 10 50 90
Relative
Speed / %