Energy Efficiency Certificate

Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series :GD20-0R4G-S2 Nominal current :2.5A
Nominal voltage :1X 220 VAC Nominal apparent power :0.95kVA
Nominal power :0.37kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 5W
Relative
Torque / %
24W 21W 21W
100 2.56% 2.21% 2.17%
91.70% 96.32% 97.74%

Losses
20W 17W 12W Relative losses
50 2.13% 1.73% 1.26% Drive Efficiency
90.11% 96.12% 98.31%

20W 19W 11W


25 2.11% 2.00% 1.12%
89.87% 95.67% 98.21%

0 10 50 90
Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
137W 148W 198W
100 37.18% 40.07% 53.6%

Losses
50 85W 98W 119W Relative losses
23.0% 26.69% 32.12%

25 75W 91W
20.40% 24.63%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series :GD20-0R7G-S2 Nominal current :4.2A
Nominal voltage :1X 220 VAC Nominal apparent power :1.6kVA
Nominal power :0.75kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 7W
Relative
Torque / %
39W 35W 38W
100 2.44% 2.24% 2.42%
92.05% 96.50% 97.35%

Losses
27W 19W 11W Relative losses
50 1.70% 1.19% 0.70% Drive Efficiency
89.12% 95.91% 96.6%

23 22W 21W
25 1.47% 1.43% 1.3%
92.34% 95.60% 96.94%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
210W 220W 283W
100 28.0% 29.9% 37.8%

Losses
50 115W 128W 155W Relative losses
15.3% 17.0% 20.6%

25 93W 112W
12.37% 15.0%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series :GD20-1R5G-S2 Nominal current :7.5A
Nominal voltage :1X 220 VAC Nominal apparent power :2.86kVA
Nominal power :1.5kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 8W
Relative
Torque / %
66W 58W 78W
100 2.32% 2.05% 2.74%
88.95% 96.33% 97.51%

Losses
44W 38W 28W Relative losses
50 1.56% 1.34% 0.99% Drive Efficiency
87.04% 96.10% 98.02%

35W 30W 32W


25 1.23% 0.97% 1.12%
85.39% 95.36% 97.17%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
334W 353W 475W
100 22.3% 23.57% 31.7%

Losses
50 167W 200W 238W Relative losses
11.13% 13.33% 23.57%

25 125W 154W
8.33% 10.3%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series :GD20-2R2G-S2 Nominal current :10A
Nominal voltage :1X 220 VAC Nominal apparent power :3.81kVA
Nominal power :2.2kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 8W
Relative
Torque / %
73W 69W 157W
100 1.94% 1.83% 4.13%
92.92% 96.98% 96.44%

Losses
51W 68W 84W Relative losses
50 1.35% 1.81% 2.22% Drive Efficiency
91.25% 96.05% 97.29%

42W 50W 50W


25 1.12% 1.35% 1.32%
89.89% 95.65% 97.61%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
414W 463W 679W
100 18.81% 21.03% 30.8%

Losses
50 209W 274W 363W Relative losses
9.51% 12.49% 16.51%

25 156W 212W
7.10% 9.67%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series :GD20-0R7G-4 Nominal current :2.5A
Nominal voltage :3X 380 VAC Nominal apparent power :1.6kVA
Nominal power :0.75kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 7W
Relative
Torque / %
44W 51W 41W
100 2.69% 3.09% 2.52%
88.09% 94.28% 96.82%

Losses
36W 37W 27W Relative losses
50 2.17% 2.25% 1.64% Drive Efficiency
80.78% 93.04% 96.6%

31W 35W 21W


25 1.88% 2.15% 1.3%
76.51% 92.47% 96.94%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
210W 229W 286W
100 27.93% 30.59% 38.2%

Losses
50 121W 143W 170W Relative losses
16.2% 19.12% 22.61%

25 97W 114W
12.91% 15.17%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series :GD20-1R5G-4 Nominal current :4.2A
Nominal voltage :3X 380 VAC Nominal apparent power :2.8 kVA
Nominal power :1.5kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 7W
Relative
Torque / %
58W 58W 61W
100 2.1% 2.09% 2.19%
90.8% 96.07% 97.52%

Losses
43W 38W 33W Relative losses
50 1.56% 1.37% 1.19% Drive Efficiency
86.67% 94.65% 97.23%

36W 28W 24W


25 1.31% 1.03% 0.88%
84.03% 94.27% 97.44%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
324W 349W 459W
100 32.4% 23.28% 30.59%

Losses
50 161W 197W 238W Relative losses
16.1% 13.13% 15.84%

25 122W 151W
12.2% 10.07%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-2R2G-4 Nominal current :5.5A
Nominal voltage :3X 380 VAC Nominal apparent power :3.6kVA
Nominal power :2.2kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 8W
Relative
Torque / %
79W 86W 95W
100 2.2% 2.37% 2.62%
92.29% 96.25% 97.18%

Losses
55W 64W 62W Relative losses
50 1.51% 1.78% 1.71% Drive Efficiency
89.98% 95.52% 96.97%

48W 49W 60W


25 1.32% 1.36% 1.67%
87.42% 94.6% 96.70%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
415W 473W 617W
100 18.85% 21.48% 28.07%

Losses
50 211W 262W 335W Relative losses
9.60% 11.91% 15.25%

25 157W 206W
7.14% 9.38%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-004G-4 Nominal current :9.5A
Nominal voltage :3X 380 VAC Nominal apparent power :6.3kVA
Nominal power :4.0kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 9W
Relative
Torque / %
108W 114W 140W
100 1.73% 1.83% 2.25%
92.98% 96.47% 97.92%

Losses
80W Relative losses
78W 89W
50 1.26% 1.43%
1.28% Drive Efficiency
97..95
90.74% 95.95%
%

64W 69W 77W


25 1.02% 1.10% 1.23%
89.07% 95.71% 97.68%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
588W 682W 930W
100 14.69% 17.05% 23.25%

Losses
50 287W 371W 474W Relative losses
7.18% 9.28% 11.84%

25 211W 285W
5.27% 7.13%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-5R5G-4 Nominal current :14A
Nominal voltage :3X 380 VAC Nominal apparent power :9.2kVA
Nominal power :5.5kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 9W
Relative
Torque / %
189W 222W 258W
100 2.05% 2.41% 2.8%
83.42% 95.03% 97.01%

Losses
107W 133W 124W Relative losses
50 1.16% 1.45% 1.34% Drive Efficiency
84.29% 93.77% 96.68%

93W 101W 143W


25 1.01% 1.09% 1.56%
87.36% 95.00% 96.78%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
756W 903W 1240W
100 13.74% 16.42% 22.56%

Losses
50 347W 457W 586W Relative losses
6.28% 8.31% 10.65%

25 247W 345W
4.50% 6.68%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-7R5G-4 Nominal current :18.5A
Nominal voltage :3X 380 VAC Nominal apparent power :12.2kVA
Nominal power :7.5kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 9W
Relative
Torque / %
189W 274W 227W
100 2.05% 2.25% 1.86%
83.42% 96.14% 98.13%

Losses
107W 126W 142W Relative losses
50 1.16% 1.04% 1.17% Drive Efficiency
84.29% 96.28% 97.71%

93W 103W 94W


25 1.01% 0.85% 0.77%
87.36% 94.92% 97.56%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
886W 1114W 1450W
100 11.8% 14.85% 19.34%

Losses
50 384W 523W 727W Relative losses
5.13% 6.98% 9.69%

25 280W 403W
3.7% 5.37%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-011G-4 Nominal current :25A
Nominal voltage :3X 380 VAC Nominal apparent power :16.45kVA
Nominal power :11kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 6W
Relative
Torque / %
254W 323W 355W
100 1.55% 1.97% 2.16%
84.69% 95.98% 97.46%

Losses
138W 171W 162W Relative losses
50 0.84% 1.04% 0.99% Drive Efficiency
86.45% 95.12% 97.44%

99W 100W 101W


25 0.61% 0.61% 0.62%
89.32% 96.62% 97.96%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
1211W 1467W 1954W
100 11.01% 13.33% 17.76%

Losses
50 512W 710W 954W Relative losses
4.65% 6.45% 8.67%

25 341W 496W
3.1% 4.50%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-015G-4 Nominal current :32A
Nominal voltage :3X 380 VAC Nominal apparent power :21.06kVA
Nominal power :15kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 7W
Relative
Torque / %
267W 306W 350W
100 1.27% 1.46% 1.66%
90.06% 96.82% 98.18%

Losses
109W 153W 164W Relative losses
50 0.52% 0.73% 0.78% Drive Efficiency
82.46% 93.42% 97.60%

88W 120W 122W


25 0.42% 0.55% 0.58%
89.90% 96.39% 97.76%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
1392W 1686W 2331W
100 9.28% 11.24% 15.54%

Losses
50 559W 798W 1124W Relative losses
3.72% 5.32% 7.49%

25 238W 585W
2.38% 3.9%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-018G-4 Nominal current :38A
Nominal voltage :3X 380 VAC Nominal apparent power :25kVA
Nominal power :18.5kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 11W
Relative
Torque / %
304W 424W 412W
100 1.22% 1.70% 1.65%
91.24% 96.7% 98.2%

Losses
186W 258W 240W Relative losses
50 0.74% 1.03% 0.96% Drive Efficiency
90.41% 96.14% 97.91%

135W 190W 171W


25 0.54% 0.77% 0.69%
88.73% 95.38% 97.65%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
1617W 2033W 2691W
100 8.74% 10.99% 14.54%

Losses
50 704W 998W 1331W Relative losses
3.8% 5.39% 7.19%

25 449W 726W
2.42% 3.92%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-022G-4 Nominal current :45A
Nominal voltage :3X 380 VAC Nominal apparent power :29.6kVA
Nominal power :22kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 11W
Relative
Torque / %
359W 455W 409W
100 1.21% 1.54% 1.38%
88.99% 96.95% 98.43%

Losses
198W 266W 257W Relative losses
50 0.67% 0.90% 0.87% Drive Efficiency
90.58% 96.52% 98.11%

138W 200W 177W


25 0.47% 0.67% 0.6%
88.76% 95.58% 97.73%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
1855W 2281W 2973W
100 8.43% 10.36% 13.51%

Losses
50 770W 1102W 1511W Relative losses
3.5% 5.01% 6.86%

25 490W 816W
2.2% 3.71%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-030G-4 Nominal current :60A
Nominal voltage :3X 380 VAC Nominal apparent power :39.5kVA
Nominal power :30kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 13W
Relative
Torque / %
280W 334W 590W
100 0.71% 0.85% 1.5%
97.92% 98.30% 98.26%

Losses
283W 356W 572W Relative losses
50 0.72% 0.9% 1.45% Drive Efficiency
96.27% 96.83% 96.92%

208W 280W 491W


25 0.53% 0.71% 1.24%
89.90% 91.08% 89.15%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
2140W 2584W 3786W
100 7.13% 8.61% 12.62%

Losses
50 973W 1376W 2132W Relative losses
3.24% 4.58% 7.1%

25 658W 1030W
2.19% 3.43%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-037G-4 Nominal current :75A
Nominal voltage :3X 380 VAC Nominal apparent power :49.4kVA
Nominal power :37kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 14W
Relative
Torque / %
686W 791W 850W
100 1.39% 1.60% 1.72%
88.80% 96.69% 98.04%

Losses
341W 432W 490W Relative losses
50 0.69% 0.88% 0.99% Drive Efficiency
89.33% 96.27% 97.85%

234W 310W 292W


25 0.47% 0.63% 0.59%
85.53% 94.27% 96.76%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
2758W 3344W 4587W
100 7.45% 9.03% 12.39%

Losses
50 1118W 1616W 2303W Relative losses
3.02% 4.36% 6.22%

25 715W 1198W
1.93% 3.23%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-045G-4 Nominal current :92A
Nominal voltage :3X 380 VAC Nominal apparent power :60.5kVA
Nominal power :45kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 21W
Relative
Torque / %
843W 991W 1003W
100 1.39% 1.64% 1.66%
89.45% 96.56% 98.03%

Losses
420W 605W 588W Relative losses
50 0.69% 1.00% 0.97% Drive Efficiency
88.80% 96.01% 97.85%

295W 470W 459W


25 0.49% 0.78% 0.76%
85.78% 94.90% 97.23%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
2936W 3626W 5248W
100 6.52% 8.05% 11.66%

Losses
50 1196W 1737W 2605W Relative losses
2.65% 3.86% 5.78%

25 774W 1300W
1.72% 2.89%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-055G-4 Nominal current :115A
Nominal voltage :3X 380 VAC Nominal apparent power :75.7kVA
Nominal power :55kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 22W
Relative
Torque / %
955W 1116W 1059W
100 1.26% 1.47% 1.40%
91.02% 96.99% 98.33%

Losses
519W 672W 669W Relative losses
50 0.69% 0.89% 0.88% Drive Efficiency
89.96% 96.64% 98.09%

386W 540W 504W


25 0.51% 0.71% 0.67%
87.91% 95.90% 97.79%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
3320W 4196W 5943W
100 6.03% 7.62% 10.80%

Losses
50 1454W 2157W 3199W Relative losses
2.64% 3.92% 5.81%

25 991W 1695W
1.80% 3.08%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-075G-4 Nominal current :150A
Nominal voltage :3X 380 VAC Nominal apparent power :98.7kVA
Nominal power :75kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 22W
Relative
Torque / %
1102W 1269W 1406W
100 1.12% 1.29% 1.42%
92.71% 97.47% 98.37%

Losses
602W 683W 748W Relative losses
50 0.61% 0.69% 0.76% Drive Efficiency
91.7% 97.51% 98.45%

435W 500W 539W


25 0.44% 0.51% 0.55%
90.70% 97.27% 98.35%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
3727W 4869W 7483W
100 4.97% 6.49% 9.98%

Losses
50 1577W 2483W 4048W Relative losses
2.10% 3.31% 5.39%

25 1185W 2000W
1.58% 2.67%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-090G-4 Nominal current :180A
Nominal voltage :3X 380 VAC Nominal apparent power :118.5kVA
Nominal power :90kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 25W
Relative
Torque / %
1365W 1531W 1751W
100 1.15% 1.29% 1.48%
94.74% 97.28% 98.25%

Losses
704W 766W 1061W Relative losses
50 0.59% 0.65% 0.90% Drive Efficiency
93.70% 96.92% 98.07%

495W 560W 598W


25 0.42% 0.47% 0.50%
95.27% 97.59% 98.51%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
4515W 5671W 8843W
100 5.01% 6.30% 9.82%

Losses
50 1874W 2746W 4751W Relative losses
2.08% 3.05% 5.28%

25 1395W 2270W
1.55% 2.52%

0 10 50 90
Relative
Speed / %
Energy Efficiency Certificate
Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD20-110G-4 Nominal current :215A
Nominal voltage :3X 380 VAC Nominal apparent power :141.5kVA
Nominal power :110kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 28W
Relative
Torque / %
1842W 2317W 2523W
100 1.30% 1.64% 1.78%
94.29% 96.76% 97.95%

Losses
888W 1055W 1129W Relative losses
50 0.63% 0.75% 0.80% Drive Efficiency
94.27% 96.96% 98.16%

611W 680W 794W


25 0.43% 0.48% 0.56%
92.80% 96.22% 97.49%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
5362W 7487W 11436W
100 4.87% 6.80% 10.39%

Losses
50 2428W 4025W 6299W Relative losses
2.20% 3.66% 5.72%

25 1711W 3100W
1.55% 2.81%

0 10 50 90
Relative
Speed / %