You are on page 1of 1

Energy Efficiency Certificate

Drive efficiency according to IEC/EN 61800-9-2 (supersedes EN 50598-2)

Efficiency data for the Drive


Series : GD350A-315G/355P-4 Nominal current :600A
Nominal voltage : AC 3PH 380V Nominal apparent power :394.8kVA
Nominal power :315kW Nominal frequency :50Hz
Overload :Heavy Duty

Efficiency data for the Drive


Standby losses: 80W
Relative
Torque / %
3104W 6436W 8779W
100 0.79% 1.63% 2.22%
96.05% 96.46% 97.48%

Losses
1364W 3683W 5362W Relative losses
50 0.35% 0.94% 1.36% Drive Efficiency
96.31% 96.57% 96.90%

2222W 3694W 3889W


25 0.56% 0.94% 0.98%
92.47% 94.65% 97.06%

0 10 50 90 Relative
Speed / %

Efficiency data for the Drive + motor (standard IE2 reference motor)

Relative
Torque / %
12554W 19981W 31566W
100 3.9% 6.3% 9.8%

Losses
50 5459W 10928W 17332W Relative losses
1.7% 3.4% 5.5%

25 5057W 9364W
1.6% 2.9%

0 10 50 90
Relative
Speed / %

You might also like