You are on page 1of 1

CIRCULAR COLUMN AXIAL LOAD ENHANCEMENT

Code: NCHRP/ AASHTO LRFD 2012 Designed by: Heherson B. Juan,msce


Project: Retrofitting of Ka-Tialo Bridge Columns Date: March 25, 2021
Location: San Jose Del Monte, Bulacan Location/Ref. : Column 1-mid-bot

CODE: NCHRP/ AASHTO LRFD 2012


Choose Tyfo Product: SCH-41
Column Data:
lu (Column height) lu= 4 m
Ø (Column diameter) Ø= 2 m
f'c (Compression Concrete Strength f'c= 23 MPa
Vertical Reinforcement n= 40 Ø= 32 mm
Ag (Area Gross) Ag= 3141593 mm2
Ast (Area Vertical Reinforcement) Ast= 32169.9 mm2
fy (Yield Strength of Rebar) fy= 414 MPa
f (Reduction factor) f= 0.75 Article 5.3.2.2
Pu (Required Axial Force) Pu= 51759.2 kN Ø
lu/Ø (Aspect Ratio) lu/Ø 2.000 < 8 FRP Retrofit Possible!
FRP reinforcement:
Tyfo® Properties Confinement type tied Section Wrap
Fiber Type Carbon ke 0.8 Around
Tensile Strength 986 MPa
Tensile Modulus 230 GPa Nfrp Strength per width of FRP reinforcement 3
Thickness 1 mm corresponding to a strain of 0.004 plies
efrp 0.004286957 mm ffrp 0.85
Tensile strength of a single layer FRP reinforcement @ 0.00429 mm strain Nfrp = 986 kN/m lu (Column height)
Maximum n layers 6 (For Ductility Requirement)
n layer/s 3 Total FRP QTY
2
Existing Pr 44464.53 kN 75.40 m
Updated Pr after
51905.134 kN % increase in axial load carrying capacity 16.73 %
fiber strengthening