Professional Documents
Culture Documents
Notes :
ITEM
ITEM / DESCRIPTION DP DE LE/SE REMARKS
NO.
I GENERAL
1 Doc.format, doc.no.,titles, sub titles, as per Std. format or Proj. requirements
2 Design basis write-up (or ref. to separate design criteria where applicable)
incl.modelling, design methodology, basic loads & load combination
3 Input data for foundation design : Check whether foundation layout & loading
data from vendor are the latest revisions & good for engg. / construction
4 Tabulation of basic loads & combinations of service loads / along with
co-ordinate system (X,Y & Z) for loads
5 If STAAD output gives support reactions in factored loads, the same
to be converted to service loads by dividing with appropriate load factor
6 Check signs of moments, if std. spread sheet is used
7 Check if all critical load combinations are considered for bearing capacity
check & footing / pile cap design
8 Check if dimensions chosen will foul with adjacent foundation especially of
other structures / buildings nearby
9 Founding depth based on Soil Report /Contour map(depth of filling)/technical
reqmts. (clearance for trenches / pipes or based on adjacent fdns.)
10 For combined footings, check if signs of moments, shears & vertical loads
from different columns are considered correctly
11 Partial Contact - Check formula used for bearing press. calculations when
ecc.>L/6 or B/6 (L & B-Fdn. dimensions) (Use Teng's chart for biaxial bendings)
12 Clear cover, grade of concrete specific to the project for effective depth &
stress calculations
13 Pedestal height above footing / pile cap top > anchor bolt embedment for
steel columns
14 Pedestal reinforcement check for maximum axial load with moment &
minimum axial load (or tension) with moment
15 Pedestal dimensions & footing / pile cap depth, minimum reinforcement,
dia./ spacing of bars etc. as per stipulations
16 Sketch / tabulation of final dimensions & reinforcement provided