The GCU combines the SAACKE SSB 500 low emission rotating One thing is clear: LNG transport will increase considerably in the
flame burner with an air-cooled steel combustion chamber. next few years. This makes it even more important to ensure that
All of the components have been so compactly designed that the boil-off gases are burnt off at sea in a safe and environmentally
15 meter high, 36-ton plant can be accommodated in the area friendly manner. SAACKE introduced the Gas Combustion Unit to
of the funnel and saves valuable construction space in the ship. the market, as a completely new development, as early as 2002.
The fore- and after-combustors as well as the burner and the gas Since then, this core competence has constantly been expanded –
fittings were manufactured in Bremen, while the outer shell was most recent example: the 100% free-flow solution. This success
manufactured at SAACKE‘s factory in Qingdao. This is where shows that the company is on the right track: to date 80 SAACKE
the individual GCU components were also brought together and GCUs have been installed in ships worldwide.
assembled before ultimately being installed in the ship on-site at
the shipyard in Shanghai.
Burner performance map: Massflow over pressure
5500
153 250
5200
5000
GCU max. flow rate achieved
4000
3500
Available max. flow rate at
3000 fully open control valve
Rain-proof design to avoid corrosion and wearing of the 2500
GCU components, especially the burner and the combustion
Massflow rate [kg/h]
2000
1898
chamber bottom 1500
Available min. flow rate at fully closed control valve
1000
T he inner lining in the combustion chamber provides a cold
500
and therefore strong structure of the GCU 520 520
0
0 50 100 150 200 250 300
High air excess provides low flame temperature for Supply pressure[mbar g] at gas train inlet
low heat radiation and low NO X emissions
No flame touching of the combustion chamber wall if Technical data: GCU
the ship is rolling in heavy sea and therefore no wearing or Plant capacity 5.2 t/h gas
damaging of the combustion chamber
Flue gas outlet temperature <450 °C
No belt driven fans for low maintenance cost
Control range 1:10
Oil pilot burner for unlimited continuous operation
if required during special circumstances Fuel Boil-off gas, marine gas oil (support fuel)
Controlled fuel air ratio for safe combustion and
low emissions
The SAACKE GCU
For maintenance it is possible to remove or replace inner
in production.
parts like combustion chamber and burner via funnel
SAACKE GmbH
Südweststraße 13 Tel. +49 421 6495-0 marine@saacke.com
28237 Bremen, Germany Fax +49 421 6495-5363 www.saacke.com