You are on page 1of 6

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Pump

FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability

Click here to view the


Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner
Spring
(Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
KENR5632-01
February 2014

D10T2 Track-Type Tractor


Cooling System
RAB1-UP
JJW1-UP

© 2014 Caterpillar, All Rights Reserved Printed in U.S.A.


COMPONENT AND TAP TABLE

Component Locations
Part Machine Schematic
Description
Number Location Location
COOLER GP - ENGINE OIL 358-2305 1 C-2
COOLER GP - XMSN OIL 375-0765 2 B-3
HEATER GP - HEAT AND AIR CONDITIONING (CAB) 418-6840 3 E-1
PUMP GP - JACKET WATER 348-4037 4 D-2
RADIATOR GP - COOLING 393-5047 5 E-7
SENSOR GP - THERMOSTAT 234-5012 6 C-6
TANK GP - COOLING 359-6447 7 F-6
TURBO GP - LEFT HAND 375-5493 8 B-7
TURBO GP - RIGHT HAND 375-5493 9 C-4

TAP LOCATIONS
Pressure, Sampling, Sensor
Schematic
Tap Number Description
Location
SOS ENGINE COOLANT SAMPLING PORT C-2
(7) TANK GP - COOLING
359-6447

VENT VENT
TANK

SHUNT

(5) RADIATOR GP - COOLING


393-5047

RADIATOR CORE RADIATOR CORE

(3) HEATER GP - CAB


HEAT AND AIR CONDITIONING
418-6840

BYPASS PUMP
JACKET WATER

(4) PUMP GP - JACKET WATER


348-4037
(6) SENSOR GP -
THERMOSTAT
234-5012

SOS
DRAIN
(9) TURBO GP - RIGHT HAND
375-5493

(1) COOLER GP - ENGINE OIL


(Dimensions: 25 inches x 24 inches)

358-2305

CYLINDER HEAD
KENR5632-01

TURBO TURBO

ENGINE (2) COOLER GP - XMSN OIL


(8) TURBO GP - RIGHT HAND BLOCK 375-0765
375-5493

DRAIN
12 Page,

COOLANT CIRCUIT COLOR DESCRIPTIONS


LINE PATTERNS
VENT TO TANK
Pressure Line RETURN TO WATER JACKET PUMP
CAB HEATER CIRCUIT
Pilot / Load Sensing Pressure RETURN CIRCUIT
DRAIN / RETURN LINE
Drain / Return Lines
WATER JACKET PUMP AND CIRCUIT
Component Group
THIS SCHEMATIC IS FOR THE D10T2 TRACK-TYPE TRACTOR COOLING SYSTEM
CALLOUTS
MEDIA NUMBER: KENR5632-01
YY Taps (Pressure, Sampling, Sensor - by letter) SCHEMATIC PART NUMBER: 359-6509, CHANGE: 03, VERSION: -
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
Callout Number Component
in neutral and with parking brake set.
(Machine Location from (52) VALVE GP - CONTROL Name
Component Locations Table)
138-1234 Part Number
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
MACHINE VIEW
VIEW ALL CALLOUTS

5 7

8
9
1 2 6
SOS
4

You might also like