You are on page 1of 19

COPYRIGHT NOTICE & TERMS OF USE

This document is for use by Saipem Spa employees only. If you are not a Saipem Spa
employee, you are NOT authorised to view this document and you are liable to copyright
violation. The document is the copyright of the Publisher. All rights reserved.

The contract allowing you to use this document contains the following terms of use which must be
followed:-

(a) You may view and print a single copy of a document contained in the Subscription for reference
purposes only and only for internal purposes within the site on which such copies are made,
providing such copies are dated and destroyed after the reference usage, typically no more than 60
working days after use, subject to the exception described in clause (b) below. Such copies may not
be filed to form part of any hard copy reference collection.

(b) Where you have a specification or tender requirement to reproduce a document or portions of a
document as part of its documentation for external submission in response to a tender, the necessary
pages of the document, including the whole document if required, may be reproduced and submitted
provided a copyright notice is included. You shall notify SAI Global of any such use. For internal and
archival purposes only, a paper copy may be attached to your documentation and shall be
considered a permanent part of that documentation.

(c) Under no circumstances are you permitted to reproduce all or part of any document for external
use or for use in any other site or group of sites, except as set forth in (b) above.

(d) You may not remove any proprietary markings or electronic watermarks, including any
copyrights and trademarks.

(e) You may copy a maximum of 25% of the content of a document within the Subscription and
paste it to another document for internal use. The copied content in the new document must contain
a copyright notice “Copyright [name of publisher] Date where date is the date of copyrighted material.
Such content is licensed for use only for the duration of the relevant Subscription.

(f) For ISO standards, the material is reproduced from ISO publications under International
Organization for Standardization (ISO) Copyright License number SAI GLOBAL/MCEA/2008. Not for
resale. No part of these ISO publications may be reproduced in any form, electronic retrieval system
or otherwise, except as allowed under the copyright law in the country of use, or with the prior written
consent of ISO (Case postale 56, 1211 Geneva 20, Switzerland, email: copyright@iso.org) or ISO’s
Members.

SAI GLOBAL, Index House, Ascot, Berks, SL5 7EU, UK


: +44 (0)1344 636300. Fax: +44 (0)1344 291194. E-mail: standards@saiglobal.com. www.ili.co.uk

SAI GLOBAL, 610 Winters Avenue, Paramus, NJ 07652, USA


201-986-1131. Fax: 201-986-7886. E-mail: sales@ili-info.com. www.ili-info.com

SAI GLOBAL, 286 Sussex Street, Sydney NSW 2000, Australia


: +61 2 8206 6060. Fax: +61 2 8206 6019. E-mail: sales@saiglobal.com. www.saiglobal.com
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

INTERNATIONAL IEC
STANDARD 60384-14-1
QC 302401
Second edition
2005-07

Fixed capacitors for use in electronic equipment –

Part 14-1:
Blank detail specification:
Fixed capacitors for electromagnetic
interference suppression and connection
to the supply mains – Assessment level D

Reference number
IEC 60384-14-1:2005(E)

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

Publication numbering
As from 1 January 1997 all IEC publications are issued with a designation in the
60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1.

Consolidated editions
The IEC is now publishing consolidated versions of its publications. For example,
edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the
base publication incorporating amendment 1 and the base publication incorporating
amendments 1 and 2.

Further information on IEC publications


The technical content of IEC publications is kept under constant review by the IEC,
thus ensuring that the content reflects current technology. Information relating to
this publication, including its validity, is available in the IEC Catalogue of
publications (see below) in addition to new editions, amendments and corrigenda.
Information on the subjects under consideration and work in progress undertaken
by the technical committee which has prepared this publication, as well as the list
of publications issued, is also available from the following:

• IEC Web Site (www.iec.ch)

• Catalogue of IEC publications


The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to
search by a variety of criteria including text searches, technical committees
and date of publication. On-line information is also available on recently issued
publications, withdrawn and replaced publications, as well as corrigenda.

• IEC Just Published


This summary of recently issued publications (www.iec.ch/online_news/ justpub)
is also available by email. Please contact the Customer Service Centre (see
below) for further information.

• Customer Service Centre


If you have any questions regarding this publication or need further assistance,
please contact the Customer Service Centre:

Email: custserv@iec.ch
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

INTERNATIONAL IEC
STANDARD 60384-14-1
QC 302401
Second edition
2005-07

Fixed capacitors for use in electronic equipment –

Part 14-1:
Blank detail specification:
Fixed capacitors for electromagnetic
interference suppression and connection
to the supply mains – Assessment level D

 IEC 2005  Copyright - all rights reserved


No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.

International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch

Com mission Electrotechnique Internationale


International Electrotechnical Com m ission
PRICE CODE M
Международная Электротехническая Комиссия
For price, see current catalogue

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

–2– 60384-14-1  IEC:2005(E)

INTERNATIONAL ELECTROTECHNICAL COMMISSION


____________

FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT

Part 14-1: Blank detail specification:


Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains –
Assessment level D

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard CEI 60384-14-1 has been prepared by IEC technical committee 40:
Capacitors and resistors for electronic equipment.

This second edition of CEI 60384-14-1 cancels and replaces the first edition published in
1993. It constitutes a technical revision. All changes that have been agreed upon can be
categorized as minor revisions.

The text of this standard is based on the following documents:

FDIS Report on voting


40/1553/FDIS 40/1587/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

60384-14-1  IEC:2005(E) –3–

This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

It should be read in conjunction with IEC 60384-1 and IEC 60384-14.

This standard forms Part 14-1 of IEC 60384, which is published under the general title Fixed
capacitors for use in electronic equipment.

Part 1: Generic specification

Part 14 is composed as follows:

Part 14: Sectional specification – Fixed capacitors for electromagnetic interference


suppression and connection to the supply mains
Part 14-1: Blank detail specification – Fixed capacitors for electromagnetic interference
suppression and connection to the supply mains – Assessment level D
Part 14-2: Blank detail specification – Fixed capacitors for electromagnetic interference
suppression and connection to the supply mains – Safety tests only
Part 14-3: Blank detail specification – Fixed capacitors for electromagnetic interference
suppression and connection to the supply mains – Assessment level DZ
NOTE For the complete list of all the parts, see IEC 60384-14.

The QC number that appears on the front cover of this publication is the specification number in the
IEC Quality Assessment System for Electronic Components (IECQ).

The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be

• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.

A bilingual version of this standard may be issued at a later date.

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

–4– 60384-14-1  IEC:2005(E)

FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT

Part 14-1: Blank detail specification:


Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains –
Assessment level D

Blank detail specification

A blank detail specification is a supplementary document to the sectional specification and


contains requirements for style and layout and minimum content of detail specifications. In the
preparation of detail specifications, the content of 1.4 of the sectional specification shall be
taken into account.

Identification of the detail specification and of the component

The first page of the detail specification should have the layout recommended on the next
page of this blank detail specification. The numbers between brackets correspond to the
following information which shall be inserted at the position indicated.

[1] The name of the National Standards Organization under whose authority the detail
specification is published and, if applicable, the organization from which the detail
specification is available.
[2] The IECQ symbol and the number allotted to the detail specification by the IECQ
General Secretariat.
[3] The number and issue number of the IECQ generic or sectional specification as
relevant; also the national reference if different.
[4] If different from the IECQ number, the national number of the detail specification, date
of issue and any further information required by the national system, together with any
amendment numbers.
[5] A brief description of the component or range of components.
[6] Information on typical construction (when applicable).

For [5] and [6] the text to be given in the detail specification should be suitable for an entry in
the IECQ Register of Approvals.

[7] Outline drawing with main dimensions which are of importance for inter-changeability
and/or reference to the appropriate national or international documents for outlines.
Alternatively, the drawing may be given in an annex to the detail specification, but [7]
should always contain an illustration of the general outer appearance of the component.
[8] The level(s) of quality assessment covered by the detail specification, as appropriate.
[9] Reference data giving information on the most important properties of the component
which allow comparison between the various component types intended for the same or
similar applications.

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

60384-14-1  IEC:2005(E) –5–

[1] [2]
IEC 60384-14-1xx
QC 302401-xxx
[4]
IEC 60384-14-1
QC 302401

ELECTRONIC COMPONENTS OF [3]


ASSESSED QUALITY – DETAIL
SPECIFICATION IN ACCORDANCE WITH:

[7] [5]
Outline drawing (...angle projection): FIXED CAPACITORS FOR
ELECTROMAGNETIC INTERFERENCE
SUPPRESSION AND CONNECTION
TO THE SUPPLY MAINS
[6]
TYPICAL CONSTRUCTION (Examples):

(Other shapes are permitted within the dimensions


Assessment level D [8]
given, see Table 1)
For notes [ ], see preceding page.

REFERENCE DATA: [9]

Information on the availability of components qualified to this detail


specification is given in IEC QC 001005.

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

–6– 60384-14-1  IEC:2005(E)

1 General data

1.1 Method of mounting for vibration and bump or shock tests

See 1.4.2 of IEC 60384-14.

1.2 Dimensions

Table 1 – Case-size dimensions

Case-size Dimensions
reference mm
L1 W H L2 L3 L4 ...

NOTE 1 When there is no case-size reference, Table 1 may be omitted and


the dimensions should be given in Table 2, which then becomes Table 1.
NOTE 2 The dimensions should be given as maximum dimensions or as
nominal dimensions with the tolerance.

1.3 Ratings and characteristics


Capacitance range (see Table 2)
Tolerance on rated capacitance
Rated voltage (see Table 2)
Climatic category
Rated temperature
Tangent of loss angle
Insulation resistance

Table 2 – Values of capacitance related to voltages and case sizes

Rated voltage
Case size Case size Case size Case size

Rated capacitance
(in pF and/or nF)

1.4 Normative references

The following referenced documents are indisipensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.

ICE 60384-1, Fixed capacitors for use in electronic equipment – Part 1: Generic specification
ICE 60384-14, Fixed capacitors for use in electronic equipment – Part 14: Sectional
specification: Fixed capacitors for electromagnetic interference suppression and connection to
the supply mains

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

60384-14-1  IEC:2005(E) –7–

1.5 Marking

The marking of the capacitor, if any, and the packing shall be in accordance with 1.6 of the
sectional specification.
NOTE The details of the marking of the component and packing should be given in full in the detail specification.

1.6 Ordering information

Orders for capacitors covered by this specification shall contain, in clear or in coded form, the
following information:

a) rated capacitance;
b) tolerance on rated capacitance;
c) rated voltage;
d) manufacturer's type designation;
e) number and issue reference of the detail specification and style reference.

1.7 Certified records of released lots

Required/not required.

1.8 Additional information (not for inspection purposes)

1.9 Additional or increased severities or requirements to those specified in the


generic and/or sectional specification

NOTE Additional or increased requirements should be specified only when essential.

Table 3 – Other characteristics

This table shall be used for defining characteristics which are additional
to, or more severe than, those given in the sectional specification.

2 Inspection requirements

2.1 Procedures

2.1.1 For qualification approval, the procedures shall be in accordance with 3.4 of the sec-
tional specification.

2.1.2 For quality conformance inspection, the test schedule (Tables 4 and 5) includes
sampling, periodicity, severities and requirements. The formation of inspection lots is covered
by 3.5.1 of IEC 60384-14.

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

–8– 60384-14-1  IEC:2005(E)

Table 4 – Test schedule for lot-by-lot tests (Group A and B inspection) –


Assessment level D
a a
Subclause number and test Conditions of test IL AQL Performance
a
% requirements
b

Group A1 Non-destructive II 1,5


4.1 Visual examination No visible damage
Any marking on the capacitor
shall be legible and correct
4.1 Dimensions (gauging) As specified in Table 1 of this
specification
Group A2 Non-destructive II 0,25
4.2.2 Capacitance Within specified tolerance
4.2.4 Resistance Within specified tolerance
(if applicable)
4.2.3 Tangent of loss angle Frequency ... Within specified limits
(metallized and ceramic
capacitors only)
4.2.1 Voltage proof Method ... No permanent breakdown or
(Test A) flashover
4.2.5 Insulation resistance Method: ... See Table 12
(Test A)
Group B1 Destructive S-3 2,5
4.5 Solderability Without ageing Methods 1 and 2: good
(if applicable) Method ... tinning
Method 3: < 3 s
a
Clause numbers of test and conditions/requirements refer to IEC 60384-14.
b
IL = inspection level; AQL = acceptance quality level.

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

60384-14-1  IEC:2005(E) –9–

Table 5 – Test schedule for periodic tests (Group C inspection)


Assessment level D
a a b
Subclause number and test Conditions of test Performance
a
requirements
p n c
Group C1A Destructive 6 6 0
4.1 Dimensions (detail) See Tables 1 and 9 of this
specification
4.4.1 Initial measurements Capacitance
Tan δ (if applicable)
Resistance (if applicable)
4.3 Robustness of Severity: ...
terminations
Visual examination No visible damage
4.4 Resistance to No pre-drying
soldering heat Method: 1A or 1B
4.19 Component solvent Solvent: ....
resistance Solvent temperature: ...
(if applicable) Method 2
Recovery: ...
4.4.2 Final measurements Visual examination No visible damage
Capacitance See Table 13

Tan δ (if applicable) For reference


Resistance (if applicable) See Table 13

Group C1B Destructive 6 12 0


4.5 Solderability Without ageing Methods 1 and 2: good
(if applicable) Method: ... tinning
Method 3: < 3 s
4.20 Solvent resistance of the Solvent: ... Marking shall remain
marking Solvent temperature: ... legible
Method 1
Rubbing material: Cotton
wool
Recovery: ...
4.6 Rapid change of T A = Lower category
temperature temperature
T B = Upper category
temperature
Five cycles
Duration t = 30 min
4.6.1 Final inspection Visual examination No visible damage
c
4.7 Vibration Mounting as in 1.1 of this
specification
Severity: ...
4.7.2 Final inspection Visual examination No visible damage
c
4.8 Bump Mounting as in 1.1 of this
or specification
c
4.9 Shock Severity: ...
4.8.2 Final measurements Visual examination No visible damage
or
4.9.2 Capacitance See 4.8.2 or 4.9.2
Tan δ (if applicable) Specify limit
Resistance (if applicable) See Table 14

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

– 10 – 60384-14-1  IEC:2005(E)

Table 5 (continued)
a a b
Subclause number and test Conditions of test Performance
a
requirements
p n c
Group C1 Destructive 6 18 1
4.10 Container sealing Test Qc or Test Qd, No evidence of leakage
(if applicable, if required) as applicable
4.11 Climatic sequence
4.11.1 Initial measurements Measurements made in 4.4.2,
4.8.2 or 4.9.2 as appropriate
4.11.2 Dry heat No measurements
4.11.3 Damp heat, cyclic,
first cycle
4.11.4 Cold No measurements
4.11.5 Damp heat, cyclic, No measurements
remaining cycles
4.11.6 Final measurements Visual examination No visible damage
Any marking shall be legible
Capacitance See Table 14
Resistance (if applicable) See Table 14
Tan δ (if applicable) See Table 14
Voltage proof See Table 14
Insulation resistance See Table 14
Group C2 Destructive 6 10 0
4.12 Damp heat, steady state
4.12.1 Initial measurements Capacitance
Resistance (if applicable)
Tan δ (metallized capacitors
only)
4.12.2 Test conditions Ceramic capacitors:
half the sample U R applied;
other half no voltage applied

Other capacitors:
no voltage applied
4.12.3 Final inspection and Visual examination No visible damage
measurements Marking legible
Capacitance See Table 15
Resistance (if applicable) See Table 15
Tan δ (if applicable) See Table 15
Voltage proof See Table 15
Insulation resistance See Table 15

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been
A00836277 29 Sep 09 - Saipem SpA

60384-14-1  IEC:2005(E) – 11 –

Table 5 (continued)
a a b
Subclause number and test Conditions of test Performance
a
requirements
p n c
Group C3 Destructive
X-capacitors 3 12 0
Y-capacitors 3 12 0
Lead-through capacitors 3 6 0
4.13.1 Initial measurements Capacitance
Resistance (if applicable)
Tan δ (metallized capacitors
only
4.13 Impulse voltage 3 impulses: full wave See 4.13.2. and 4.13.3
Peak voltage: see Table 1 and
Table 2
4.14 Endurance Duration: 1 000 h
voltage, current and
temperature: see 4.14.3;
4.14.4, 4.14.5 and 4.14.6
4.14.7 Final inspection and Visual examination No visible damage
measurements Marking legible
Capacitance See Table 16
Resistance (if applicable) See Table 16
Tan δ (if applicable) See Table 16
Voltage proof See Table 16
Insulation resistance See Table 16
Group C4 Destructive 6 6 1
4.15 Charge and discharge Only for metallized film
(if applicable) metallized paper and ceramic
capacitors and
RC units using such capacitors
4.15.1 Initial measurements Group 0 measurements may be
used, provided the measuring
conditions are the same as
required for this test; in
addition, except for RC-units,
tan δ shall be measured at:
10 kHz for C ≤ 1 µF
1 kHz for C > 1 µF
4.15.3 Final measurements Capacitance See Table 17
Tan δ at same frequency See Table 17
as initial measurement
(not for RC units)
Resistance (if applicable) See Table 17
Insulation resistance See Table 17
Group C5 Non-destructive 12 4 1
4.16 Radiofrequency Specify method Specify limits
characteristics (if required)
Group C6 Destructive 12 6-18 0
4.17 Passive flammability See 4.17.1
Group C7 Destructive 12 24 0
4.18 Active flammability See 4.18.4
measurements

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

– 12 – 60384-14-1  IEC:2005(E)

Table 5 (continued)

a Clause numbers of test and conditions/requirements refer to ICE 60384-14.


b p = periodicity in months, n = sample size; c = acceptance criterion (number of nonconforming items).
c These tests are required to be carried out every 12 months only.

___________

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

Standards Survey

The IEC would like to offer you the best quality standards possible. To make sure that we
continue to meet your needs, your feedback is essential. Would you please take a minute
to answer the questions overleaf and fax them to us at +41 22 919 03 00 or mail them to
the address below. Thank you!

Customer Service Centre (CSC)


International Electrotechnical Commission
3, rue de Varembé
1211 Genève 20
Switzerland
or

Fax to: IEC/CSC at +41 22 919 03 00

Thank you for your contribution to the standards-making process.

Nicht frankieren
Ne pas affranchir

A Prioritaire
Non affrancare
No stamp required

RÉPONSE PAYÉE
SUISSE

Customer Service Centre (CSC)


International Electrotechnical Commission
3, rue de Varembé
1211 GENEVA 20
Switzerland

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

Q1 Please report on ONE STANDARD and Q6 If you ticked NOT AT ALL in Question 5
ONE STANDARD ONLY. Enter the exact the reason is: (tick all that apply)
number of the standard: (e.g. 60601-1-1)
.............................................................
standard is out of date R
standard is incomplete R
standard is too academic R
Q2 Please tell us in what capacity(ies) you standard is too superficial R
bought the standard (tick all that apply).
I am the/a:
title is misleading R
I made the wrong choice R
purchasing agent R other ....................................................
librarian R
researcher R
design engineer R Q7 Please assess the standard in the
safety engineer R following categories, using
testing engineer R the numbers:
marketing specialist R (1) unacceptable,
(2) below average,
other.....................................................
(3) average,
(4) above average,
(5) exceptional,
Q3 I work for/in/as a:
(6) not applicable
(tick all that apply)

manufacturing R timeliness .............................................

consultant R quality of writing....................................


technical contents.................................
government R logic of arrangement of contents ..........
test/certification facility R tables, charts, graphs, figures ...............
public utility R other ....................................................
education R
military R
other.....................................................
Q8 I read/use the: (tick one)

Q4 This standard will be used for: French text only R


(tick all that apply) English text only R
general reference R both English and French texts R
product research R
product design/development R
specifications R Q9 Please share any comment on any
tenders R aspect of the IEC that you would like
quality assessment R us to know:
certification R ............................................................
technical documentation R ............................................................
thesis R ............................................................
manufacturing R ............................................................
other..................................................... ............................................................
............................................................
............................................................
Q5 This standard meets my needs:
(tick one) ............................................................
............................................................
not at all R ............................................................
nearly R ............................................................
fairly well R ............................................................
exactly R
A00836277 29 Sep 09 - Saipem SpA
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.
A00836277 29 Sep 09 - Saipem SpA

ISBN 2-8318-8075-0

-:HSMINB=] U\ZY:
ICS 31.060.10

Typeset and printed by the IEC Central Office


GENEVA, SWITZERLAND

A00836277 29 Sep 09 - Saipem SpA


Single user license only. Copying and Networking Prohibited. This copy has been made under license by SAI Global.