You are on page 1of 1

A1 DO NOT SCALE DRAWING. CHECK ALL DIMENSIONS ON SITE.

GENERAL NOTES
82 83 84 85 86 87 88
9000 9000 9000 9000 9000 9000 1. All Dimensions are in Millimetres (mm) and all levels are in Meters unless otherwise
1/ 21-L2-053 1/ 21-L2-054
mentioned specifically.
1/ 21-L2-052 1/ 21-L2-055 2. Written dimensions shall be read and drawings shall not be scaled.
3. These drawings shall be read in conjunction with GA Architectural Drawings and
MEPF/ IT drawings.
NORTH 4. All locations of respective Doors & Windows shall be verified at site before
PTB-L2-B2-03-M PTB-L2-B2-03-J installation.
PTB-L2-ST-05-A 5. Sub-contractor to coordinate and verify dimensions of all the openings for doors,
windows and louvers by taking field measurements before fabrication and indicate
them in shop drawings.
E 6. Any deviation in approved Shop drawings and Site shall be brought to Client’s notice
FHC HVAC immediately before further proceeding with the works.
L2-B1-S06 L2-B1-S05 F17 F16 7. Contractor to coordinate all the Masonary anchorage devices for securing Door
HVAC L2-B1-07 L2-B1-12 Frames in concrete or masonary walls. Contractor also need to provide necessary
L2-B1-S07 PTB-L2-B2-03-C structural arrangement for dry wall to support Door Frames.
PTB-L2-B2-03-D 8. Contractor shall check and ensure the Plumb and Squareness of all the structural
openings for Door & Window frames in the walls.
9. Contractor to ensure proper grouting of the frames.
ST-05 PHE PHE 10. Contractor to coordinate and incorporate all the necessary Ironmongery provisions
L2-ST-05 PTB-L2-B1-05-A SHAFT SHAFT as per the approved door schedule.
L2-B1-S02 L2-B1-S01 11. Sub-contractor to ensure that the selection of materials complies with performance
P.R.M requirement as per specification.
L2-B1-05 12. Paint Colour, Appearance and Pattern (for cladded door) of Doors as visible to Public
FINE PTB-L2-ST-05-B PTB-L2-B1-06-A as well as for BOH Areas shall be subject to sample review and approval by Architect
DINING F19 F18 R28 and Client before physical works at site. Sub-contractor shall provide uniformly high-
9000

L2-B1-11 L2-B1-09 L2-B1-13 L2-B1-14 PTB-L2-B1-04-A quality appearance of the final visible elements.
LV 13. Sub-contractor to ensure that the glass in vision panel and also for Glass Doors will
SHAFT ELECTRICAL PRAYER
be free from any impurity & waviness.
L2-B1-S04 L2-B1-S03 ROOM
14. Sub-contractor to ensure that all the Metal Doors & Frames doesn’t contain any
L2-B1-06
PTB-L2-B1-03-H sharp edges & welding outgrown and shall be properly grinded. For Glass doors the
FEMALE MALE
edges of the glass shall be properly chamfered.
TOILET TOILET
15. Details indicated are illustrating the Design Intent. The Sub-Contractor shall submit
SWITCH BABY L2-B1-02 L2-B1-01
PTB-L2-B2-03-A Shop drawings for Review and Approval of Architect and Client.
ROOM PTB-L2-B1-08-A PTB-L2-B1-08-B CARE
16. All the Doors shall comply with Fire and Smoke Compartmentation requirements and
L2-B1-08 L2-B1-04 shall be as per the approved Fire Strategy requirements.
JC 17. Sub-contractor to produce full scale mock-up of each type of door for review and
L2-B1-03 approval by Main Contractor, Client and Architect prior to commencement of work.
18. Subcontractor to protect completed works as per Client and Main Contractor
requirements and ensure no damage /deterioration at the time of handover to Client.
19. Clear opening and width mentioned here are min. required and could vary slightly
based on door profiles. Contractor to highlight any deviation in this regard to main
F PROTECTED
20.
contractor/ Architect for approval.
Kick plate shall be provided on both side of door panel unless mentioned in door
CORRIDOR
L2-B1-20 schedule.
21. Facade door are not included in door package and needs to be procurred by facade
contractor.
22. Retail doors not included in the package.
9000

DOMESTIC
GATE
CORRIDOR
L2-B2-03
G

0 10.04.2019
11-01-2021 TENDER
GOOD FOR
DESIGN
CONSTRUCTION
REV DATE DESCRIPTION

DSGN CB

DRWN AG

CHKD CB
9000

APPD CCS

NAME SIGN DATE


KEY PLAN:

NORTH

PROJECT:
GREENFIELD INTERNATIONAL
AIRPORT AT MOPA, GOA
CLIENT:
9000

GMR GOA INTERNATIONAL


AIRPORT LIMITED
EPC CONTRACTOR:
MEGAWIDE CONSTRUCTION
DMCC
ARCHITECTURAL CONSULTANT:

INTEGRATED DESIGN
ASSOCIATES LTD.
Unit 603, Block A, Shatin Industrial Centre.
5-7 Yuen Shun Circuit,
J Shatin, New Territories, Hong Kong
t: +(852) 2863 0778 | f: +(852) 2528 2226
STRUCTURAL CONSULTANT:

SY^2 + ASSOCIATES, Inc.


9801 Kamagong Street
Makati Philippines.

MEP CONSULTANT:

ESKAYEM
9000

CONSULTANTS PVT. LTD.

301, 3RD FLOOR, SWASTIK CHAMBERS,


C.S.T. ROAD, CHEMBUR, MUMBAI-400071
ESKAYEM TEL 022-25282645/46/47

FACADE CONSULTANT:

w ww . en ve l op et ec h n ik. com

PACKAGE:

K GOA INTERNATIONAL AIRPORT - PTB

TITLE:

L2 Second Floor Plan -


Zone B1

DRAWING NO.:
GGIAL-MW-PTB-AR-21-L2-012

FILE REF.: DATE:


11-01-2021
0 1 2 3 4 5

RELEASED FOR: SCALE: SIZE: REV:


1/ 09-L2-011 SCALE 1 : 100 1 : 100
GFC A1 0

You might also like